CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL...
Transcript of CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL...
![Page 1: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/1.jpg)
CUI (CORROSION UNDER INSULATION) MECHANISM THEORY AND PRACTICE
Prepared By: Mohammed AbuALRub
SAFCO Reliability Dept.
December 10, 2015
![Page 2: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/2.jpg)
No. 1
CONTENT
Introduction
CUI PhenomenaMain components of the cold insulation system
Wet Insulation
Cyclic Temperature Effect
CUI contributing Factors
Design of cold insulation system
Application of cold insulation systems
Common locations susceptible to CUI
Systems susceptible to CUI
CUI Inspection Methods & program
CUI cases
Conclusion Remarks
![Page 3: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/3.jpg)
No. 2
INTRODUCTION
In the process industry and petrochemical plants several hundreds of pipe lengths,
equipments, storage tanks an assets are insulated for process requiremnts. The common
types of insulation systems are:
Hot thermal insulation
Cold thermal insulation
In additional to the thermal insulation systems, fire proofing also present in plant assets as
per requirements.
CUI is real threat to the parent metal of insulated equipments, pipelines and structures
which are operating in the CUI susceptible temperature range [(-4) – 120] C.
![Page 4: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/4.jpg)
No. 3
CUI PHENOMENA
Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface of a
metal surface and the insulation on that surface.
CUI can be a particularly severe form of corrosion because of the difficulty in detection due
to the corrosion occurring beneath the insulation.
The most common forms of CUI are localized corrosion to the CS materials and chloride
SCC of austenitic SS
Thermal insulation and fire proofing provide the cover for the corrosion to hide underneath .
The insulation cover may trap moisture or spilled chemicals which can form corrosive media
that attacks the parent metal.
Because the corrosion is hidden from sight, the phenomena often progress undetected for
long time.
![Page 5: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/5.jpg)
No. 4
CUI PHENOMENA
Moisture combined with Oxygen is the largest contributing factor to corrosion.
The closed environment of the insulation material over the metallic component, creates
conditions that encourage build up of moisture and initiating corrosion reaction.
In general, corrosion is in the form of pitting type corrosion
![Page 6: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/6.jpg)
No. 5
THE WET INSULATION
Promote corrosion and provide the “cover” for corrosion to hide underneath.
Right environment for corrosion to start & grow in.
Spread corrosion to other areas.
Trap the moisture / spilled chemicals.
The corrosion is often more severe because the insulation material not allowing
evaporation and the insulation acting as a carrier.
Moisture occurring in one area moves through the insulation to another area causing the
corrosion to spread more rapidly.
Acids, acid gases and strong bases like caustics and salts are aggressive corrosive
agents and will accelerate existing CUI.
![Page 7: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/7.jpg)
No. 6
CYCLIC TEMPERATURE EFFECT
Cyclic temperatures that vary from below the dew point and above the ambient temp.
Wet/dry cycle develops water condensation, then baked off during hot/dry cycle.
Transition from cold/wet to hot/dry includes intermittent period of damp/warm condition with
attendant high corrosion rate.
![Page 8: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/8.jpg)
No. 7
CUI CONTRIBUTING FACTORS
Inadequate design of weather barrier
Improper application of insulating system
Improper installation of weather barrier
Workmanship
Physical abuse
Insufficient stage inspection
Insufficient maintenance
![Page 9: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/9.jpg)
No. 8
DESIGN OF COLD INSULATION SYSTEM
Temperature of the product
Design life
Protective coating
Insulating material & its thickness
Sealing of the gaps
Vapor barrier
Metal jacketing
Water proofing for metal jacketing
![Page 10: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/10.jpg)
No. 9
MAIN COMPONENTS OF THE COLD INSULATION SYSTEM
Preformed Polyurethane Foam with pre-laminated vapor barrier
Jacketing Cover Material.
Fastening material
Joint sealer.
Cradle wooden block or urethane block for supports.
Stainless steel band and clips
![Page 11: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/11.jpg)
No. 10
COLD INSULATION SYSTEM
![Page 12: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/12.jpg)
No. 11
APPLICATION OF COLD INSULATION SYSTEM
Blast clean the surface
Apply protective coating
Coat joints with adhesive material
Attach insulating material
Attach vapor barrier
Metal jacketing
Water proofing
![Page 13: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/13.jpg)
No. 12
SPECIAL CARE FOR INSULATING
Valves
Flanges
Expansion bellows
Nozzles
Pipe supports
Hangers
Attachments
![Page 14: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/14.jpg)
No. 13
COMMON LOCATIONS SUSCEPTIBLE TO CUI
All penetrations or breaches
Dead legs
Pipe hangers & supports
Valves & fittings
Pipe support
Steam tracer tubing penetration
Termination of insulation at flanges
Damages or missing insulation jacketing
Low points in the piping system
![Page 15: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/15.jpg)
No. 14
SYSTEMS SUSCEPTIBLE TO CUI
CS piping systems operating between [(-4)- 120] C.
CS piping systems operate in service above 120 but are intermittent service.
Austenitic SS piping systems that operate between (60 – 204) C are susceptible to
chloride SCC
Vibrating piping systems that cause damages to the insulation jacketing
Dead legs and attachments
systems Areas exposed to mist overspray
Areas exposed to steam vents
Areas exposed to deluge systems
Areas subject to process spills, ingress of moisture or acid vapors
Steam traced piping systems that might experience tracing leaks
Pining with deteriorated coating and or wrapping
![Page 16: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/16.jpg)
No. 15
CUI INSPECTION METHODS
External Visual Surveillance
External damages
Visible wet spots
Random stripping of insulation
NDT Methods
Profile Radiography (RT)
Infrared to detect Damp Spots
Pulse Eddy Current (EC)
![Page 17: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/17.jpg)
No. 16
CS AFTER INSULATION STRIPING
![Page 18: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/18.jpg)
No. 17
CS AFTER INSULATION STRIPING
![Page 19: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/19.jpg)
No. 18
CS LINE AFTER INSULATION STRIPPING
![Page 20: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/20.jpg)
No. 19
CONCLUSION REMARKS
1) Intermittent service temperature in the CUI susceptible range highly promotes CUI
attack.
2) Regular inspection program of insulated piping and equipment, external visual
surveillance.
3) Important factors:
Proper design and application of the insulation system.
Stage wise inspection of the insulation system during application.
Proper coating system of the substrate.
Inspection of insulation repaired locations
4) Workmanship is essential factor for healthiness of the insulation system.
![Page 21: CUI (CORROSION UNDER INSULATION) MECHANISM …nace-jubail.org/Meetings/CUI_2015/5-ABABDUL RUB-CUI...Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface](https://reader030.fdocuments.us/reader030/viewer/2022033121/5e9733f02757795a00252c27/html5/thumbnails/21.jpg)
No. 20
20