CU SERIES - Unique Eng
Transcript of CU SERIES - Unique Eng
5
CU SERIESDuct Type Split Units
M o d e l Cooling Capacity Btu/h
Cooling CapacityWatt
Page Number
CU 60 63,000 18,459 8
CU 70 72,000 21,102 10
CU 80 84,000 24,619 12
CU 100 98,000 28,720 14
CU 120 124,500 36,478 16
CU 140 144,000 42,200 18
CU 170 168,000 49,224 20
CU 200 199,000 58,320 22
Recommended Heating Elements 24
Recommended Refrigerant Tube Diameter 25
5
6Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
F E AT U R E S A N D A C C E S S O R I E S
Haargaz-Unique CU series is duct type Split Direct Expansion units. The operation of our CU air conditioners is quite and durable with low maintenance requirements and provides efficient year-round cooling and heating. Haargaz-Unique CU air conditioners are available in wide range of capacities and can be combined with electric heating elements.
Standard Features: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Designed to operate in all seasons and weather conditions.• Factory assembled and tested.• Hermetically sealed compressors, mounted on vibration isolators, equipped with internal thermal protection.• Heat exchangers are made of high quality cooper tubing, expanded into aluminum fins.• Outdoor units include direct driven axial fans, constructed of high efficiency, aerodynamic, statically and dynamically balanced low-noise blades.• Indoor units include double-inlet low-noise centrifugal blowers, statically and dynamically balanced with direct driven 3-speed motor.• Outdoor cabinets made of galvanized and oven baked pre-painted sheet metal.• Indoor unit cabinets made of durable, galvanized sheet metal with thermal and acoustic insulation sheets.• Large and easily accessible service doors.• De-icing operation.
Optional Features: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Designed for desert conditions (ambient temperature up to 45°C).• Super-low noise versions.• Electric resistance heaters.• Coated heat exchangers for superior corrosion resistance. • High and low pressure switches.
Standard Accessories:
• Electronic automatic defrosting.• 4-way reversing valve.• Over temperature protection on compressor.• Advanced control system with I/R Remote Control with daily programmable capabilities.• Suction accumulator for models CU50 and larger.• Expansion valve on large capacity units.
Optional Accessories: • Sight glass with moisture indicator.• Head pressure control.• Compressor overload protection.• Variable speed drive for outdoor unit fans.• Expansion valve on small and medium capacity units.• Indoor, wall-mounted thermostat, with weekly programmable capabilities.• Compressor crankcase heater.• Evaporating pressure regulator. • Hot gas by-pass.• Phase control relay.• Main power breaker.• Receiver.• Filter-drier.
C U S E R I E S – D U C T T Y P E S P L I T U N I T S 6 0 , 0 0 0 - 2 0 0 , 0 0 0 B T U / H
7Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
T H E R M O S T A T S , S E N S O R S A N D C L I M A T E C O N T R O L S Y S T E M S
Remote Control Unit: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• I/R transmitter, daily program scheduling.
Main Control Board: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard Features:
• 1-stage cooling and 1-stage heating.
Additional Available Features:
• 2-stage cooling and 2-stage heating.• 1-stage cooling and 1-stage heating - Additional [2nd stage] heating by electrical heating element.• 1-stage cooling only - Heating by electrical heating element or by hot water heating coil.• 1-stage cooling and 2-stage heating - Additional [3rd stage] heating by electrical heating element.• 1-stage cooling and 1-stage heating - Additional 2 heating stages [2nd and 3rd stage] by electrical heating element.• 1-stage cooling only - 2 heating stages by electrical heating elements.• 1-stage cooling only - 3 heating stages by electrical heating elements.
Receiver Panel: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• I/R (Infrared) wall-mounted receiver panel.• Features I/R receiving and on/off buttons.
Room Receiver: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• I/R wall mounted room receiver. • Enables remote control operation from another room. • Room receivers can be daisy-chained.
Thermostat: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Wall-mounted thermostat. Features local temperature read-out and adjustment, on/off buttons, mode adjustment, fan adjustment and I/R receiving.
Programmable Thermostat: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Wall-mounted thermostat. Features local temperature read-out and adjustment, on/off buttons, mode adjustment, fan adjustment, and I/R receiving. • Seven-day program scheduling.
8
CU SERIES Duct Type Split Units
Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CU60
P E R F O R M A N C E
Cooling Capacity 1Btu/h 63000
Watt 18459
Heating Capacity 2Btu/h 65500
Watt 19200
Power Consumption - Cooling / Heating Watt 5995 / 5758
Operating Current - Cooling / Heating 3 Amp 12.7 / 10.8
C.O.P - Cooling / Heating 3.08 / 3.33
Power Supply V/Ph/Hz 400V, 3Ph, 50Hz
Time Delay Fuse Amp 3x20-C
Condensate Lines - Drain Φ-mm (in) 22 (7/8")
NOTES: 1. Nominal cooling capacity based on indoor air temp. 27ºC DB/19ºC WB and outdoor air temp. 35ºC DB/24º WB 2. Nominal heating capacity based on indoor air temp. 20ºC DB and outdoor air temp. 7ºC DB/6ºC WB3. Operating current at the most loaded phase.
CUE60-A CUE60-C CUE60-AV CUE60-CV
CUC60-V, CUC60-V-SQ 2xCUC35-SQ CUC60-TD, CUC60-TD-SQ CUC60, CUC60-SQ
OUTDOOR UNIT
INDOOR UNIT
* SQ means Super Quiet model
9Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CUC60 CUC60- SQ CUC60-TD CUC60-TD-SQ CUC60-V CUC60V-SQ 2xCUC35SQ
Dimensions (LxDxH) mm 1650x500x730 1650x500x830 1650x700x1030 1650x700x1030 1300x500x1550 1300x500x1550 1150x400x780
Air Flow(At High Speed)
cfm 5000 4000 5000 4000 5000 4000 4000
m3/h 8500 6800 8500 6800 8500 6800 6800
Noise Level dBA 57 50 57 50 57 50 50
No./Axial Fan Diameter mm 2/550 2/550 1/630 1/630 2/550 2/550 2X 1/550
Outdoor Fan Motor kW 0.3 0.2 0.66 0.48 0.3 0.2 0.2
Speed (High) R.P.M 900 700 900 700 900 700 700
Coil
Face Area ft²/ m² 9.18/0.85 10.4/0.96 9.18/0.85 10.4/0.96 15/1.4 15/1.4 2X(7.5/0.7)
Rows Deep 3 3 3 3 3 3 3
Fins Spacing
Per Inch 12 12 12 12 12 12 12
Net Weight kg 150 150 150 150 150 150 2×130
Model CUE60-A CUE60-C CUE60-AV CUE60-CV
Dimensions (LxDxH) mm 1200x700x400 1040x700x480 1200x420x850 1040x500x1000
Supply Air Duct Dim. (A, B, C) mm 265, 305, 900 295, 335 265, 305, 900 295, 335
Return Air Duct Dim. (WidthxHeight) mm 980x380 850x457 980x380 850x457
High Fan Speed (No. Speeds) R.P.M 900 (3) 900 (3) 900 (3) 900 (3)
Air Flow (At High speed)
cfm 2000 2000 2000 2000
m3/h 3400 3400 3400 3400
Net Static Pressure 1 mm H2O 6 6 6 6
Number Of Blowers 2 1 2 1
Fan Type And Model
CentrifugalDD 9-9 245W
CentrifugalDD 10-10 370W
CentrifugalDD 9-9 245W
CentrifugalDD 10-10 370W
Coil
Face Area ft²/ m² 4/0.37 4.21/0.39 4/0.37 4.21/0.39
Rows Deep 2 4 4 4 4
Fins Spacing
Per Inch 12 12 12 12
Net Weight kg 79 76 79 76
I N D O O R U N I T D ATA
O U T D O O R U N I T D ATA
NOTES: 1. Net static pressure available at fan discharge at nominal capacity.2. 6 Rows deep is available on special order.3. Standard unit contain one removable and washable Air Filter. More options are available on special order.4. The unit will contain Capillary tube or Expansion valve as expansion device.
10
CU SERIES Duct Type Split Units
Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CU70
P E R F O R M A N C E
Cooling Capacity 1Btu/h 72000
Watt 21102
Heating Capacity 2Btu/h 72500
Watt 21249
Power Consumption - Cooling / Heating Watt 7400/7140
Operating Current - Cooling / Heating 3 Amp 14.7/14.4
C.O.P - Cooling / Heating 2.85/3
Power Supply V/Ph/Hz 400V, 3Ph, 50Hz
Time Delay Fuse Amp 3x25-C
Condensate Lines - Drain Φ-mm (in) 22 (7/8")
NOTES: 1. Nominal cooling capacity based on indoor air temp. 27ºC DB/19ºC WB and outdoor air temp. 35ºC DB/24º WB 2. Nominal heating capacity based on indoor air temp. 20ºC DB and outdoor air temp. 7ºC DB/6ºC WB3. Operating current at the most loaded phase.
CUE70-A CUE70-C CUE70-AV CUE70-CV
CUC70-V 2xCUC40-SQ CUC70-TD, CUC70-TD-SQ CUC70, CUC70-SQ
OUTDOOR UNIT
INDOOR UNIT
* SQ means Super Quiet model
11Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CUC70 CUC70-SQ CUC70-TD CUC70-TD-SQ CUC70-V 2xCUC40SQ
Dimensions (LxDxH) mm 1650x500x830 1650x500x830 1650x700x1030 1650x700x1030 1300x500x1550 1150x400x780
Air Flow (At High Speed)cfm 5400 4000 5000 4000 5000 4000
m3/h 9180 6800 8500 6800 8500 6800
Noise Level dBA 59 50 57 50 57 50
No./Axial Fan Diameter mm 2/550 2/550 1/630 1/630 2/550 2X 1/550
Outdoor Fan Motor kW 0.3 0.2 0.66 0.48 0.3 0.2
Speed (High) R.P.M 900 700 900 700 900 700
Coil
Face Area ft²/ m² 10.4/0.9 11.9/1 10.4/0.9 11.9/1 15/1.4 2X(7.5/0.7)
Rows Deep 3 3 3 3 2 3
Fins Spacing Per Inch 12 12 12 12 12 12
Net Weight kg 150 150 150 150 150 2×130
Model CUE70-A CUE70-C CUE70-AV CUE70-CV
Dimensions (LxDxH) mm 1300x700x440 1080x800x550 1300x420x850 1100x600x1100
Supply Air Duct Dim. (A, B, C) mm 265, 305, 900 345, 400 265, 305, 900 345, 400
Return Air Duct Dim. (WidthxHeight) mm 1100x407 880x510 980x380 880x510
High Fan Speed (No. Speeds) R.P.M 900 (3) 900 (3) 900 (3) 900 (3)
Air Flow (At High speed)cfm 2400 2400 2000 2000
m3/h 4080 4080 3400 3400
Net Static Pressure 1 mm H2O 6 8 6 8
Number Of Blowers 2 1 2 1
Fan Type And Model CentrifugalDD 9-9 370W
CentrifugalDD12-12 550W
CentrifugalDD 9-9 245W
CentrifugalDD12-12 550W
Coil
Face Area ft²/ m² 4.86/0.45 4.86/0.45 4.86/0.45 4.86/0.45
Rows Deep 2 4 4 4 4
Fins Spacing Per Inch 12 12 12 12
Net Weight kg 82 87 82 87
I N D O O R U N I T D ATA
O U T D O O R U N I T D ATA
NOTES: 1. Net static pressure available at fan discharge at nominal capacity.2. 6 Rows deep is available on special order.3. Standard unit contain one removable and washable Air Filter. More options are available on special order.4. The unit will contain Capillary tube or Expansion valve as expansion device.
12
CU SERIES Duct Type Split Units
Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CU80
P E R F O R M A N C E
Cooling Capacity 1Btu/h 84000
Watt 24619
Heating Capacity 2Btu/h 85500
Watt 25000
Power Consumption - Cooling / Heating Watt 7920/7820
Operating Current - Cooling / Heating 3 Amp 17.5/16.5
C.O.P - Cooling / Heating 3.1/3.2
Power Supply V/Ph/Hz 400V, 3Ph, 50Hz
Time Delay Fuse Amp 3x25-C
Condensate Lines - Drain Φ-mm (in) 22 (7/8")
NOTES: 1. Nominal cooling capacity based on indoor air temp. 27ºC DB/19ºC WB and outdoor air temp. 35ºC DB/24º WB 2. Nominal heating capacity based on indoor air temp. 20ºC DB and outdoor air temp. 7ºC DB/6ºC WB3. Operating current at the most loaded phase.
CUE80-A CUE80-C CUE80-AV CUE80-CV
CUC80-V 2xCUC45-SQ CUC80 TD, CUC80-TD-SQ CUC80, CUC80-SQ
OUTDOOR UNIT
INDOOR UNIT
* SQ means Super Quiet model
13Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CUC80 CUC80-SQ CUC80-TD CUC80-TD-SQ CUC80-V 2xCUC45SQ
Dimensions (LxDxH) mm 1650x500x920 1700x600x 920 1650x700x1230 1700x830x 1000 1300x500x1550 1150x400x780
Air Flow (At High Speed)cfm 5000 4000 5400 4000 5000 5000
m3/h 8500 6800 9180 6800 8500 8500
Noise Level dBA 59 50 59 50 59 50
No./Axial Fan Diameter mm 2/550 2/550 1/630 1/630 2/550 2× 1/550
Outdoor Fan Motor kW 0.3 0.2 0.66 0.48 0.3 0.2
Speed (High) R.P.M 900 700 900 700 900 700
Coil
Face Area ft²/ m² 11.9/1 11.9/1 11.9/1 11.9/1 15/1.4 2× (7.5/0.7)
Rows Deep 3 4 3 4 2 3
Fins Spacing Per Inch 12 12 12 12 12 12
Net Weight kg 188 195 195 200 188 2×140
Model CUE80-A CUE80-C CUE80-AV CUE80-CV
Dimensions (LxDxH) mm 1480x700x440 1150x800x560 1480x450x850 1150x600x1150
Supply Air Duct Dim. (A, B, C) mm 265, 305, 900 345, 400 265, 305, 900 345, 400
Return Air Duct Dim. (WidthxHeight) mm 1280x407 1023x510 980x380 880x510
High Fan Speed (No. Speeds) R.P.M 900 (3) 900 (3) 900 (3) 900 (3)
Air Flow (At High speed)cfm 2800 2800 2800 2800
m3/h 4760 4760 4760 4760
Net Static Pressure 1 mm H2O 6 6 6 6
Number Of Blowers 2 1 2 1
Fan Type And Model CentrifugalDD 9-9 370W
CentrifugalDD12-12 550W
CentrifugalDD 9-9 370W
CentrifugalDD12-12 550W
Coil
Face Area ft²/ m² 5.53/0.51 5.53/0.51 5.53/0.51 5.53/0.51
Rows Deep 2 4 4 4 4
Fins Spacing Per Inch 12 12 12 12
Net Weight kg 88 93 82 87
I N D O O R U N I T D ATA
O U T D O O R U N I T D ATA
NOTES: 1. Net static pressure available at fan discharge at nominal capacity.2. 6 Rows deep is available on special order.3. Standard unit contain one removable and washable Air Filter. More options are available on special order.4. The unit will contain Capillary tube or Expansion valve as expansion device.
14
CU SERIES Duct Type Split Units
Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CU100
P E R F O R M A N C E
Cooling Capacity 1Btu/h 98000
Watt 28720
Heating Capacity 2Btu/h 102350
Watt 29995
Power Consumption - Cooling / Heating Watt 9295/9385
Operating Current - Cooling / Heating 3 Amp 20/19.7
C.O.P - Cooling / Heating 3.1/3.2
Power Supply V/Ph/Hz 400V, 3Ph, 50Hz
Time Delay Fuse Amp 3x32-C
Condensate Lines - Drain Φ-mm (in) 2+8 (1-1/8")
NOTES: 1. Nominal cooling capacity based on indoor air temp. 27ºC DB/19ºC WB and outdoor air temp. 35ºC DB/24º WB 2. Nominal heating capacity based on indoor air temp. 20ºC DB and outdoor air temp. 7ºC DB/6ºC WB3. Operating current at the most loaded phase.
CUE100-A CUE100-C CUE100-AV CUE100-CV
CUC100-V 2xCUC50-SQ CUC100-TD CUC100
OUTDOOR UNIT
INDOOR UNIT
* SQ means Super Quiet model
15Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CUC100 CUC100-TD CUC100-V 2xCUC50SQ
Dimensions (LxDxH) mm 1700x600x920 1700x830x1000 1420x830x1000 1150x400x780
Air Flow (At High Speed)cfm 6000 6000 6000 4600
m3/h 10200 10200 10200 7820
Noise Level dBA 59 59 59 52
No./Axial Fan Diameter mm 2/550 2/630 2/550 2× 1/550
Outdoor Fan Motor kW 0.3 0.66 0.3 0.2
Speed (High) R.P.M 900 900 900 700
Coil
Face Area ft²/ m² 11.9/1.1 11.9/1.1 15/1.4 2× (7.5/0.7)
Rows Deep 4 4 4 4
Fins Spacing Per Inch 12 12 12 12
Net Weight kg 180 200 190 2×150
Model CUE100-A CUE100-C CUE100-AV CUE100-CV
Dimensions (LxDxH) mm 1500x700x480 1300x800x580 1500x550x1000 1300x600x1150
Supply Air Duct Dim. (A, B, C) mm 295, 335, 970 345, 400 295, 335, 970 345, 400
Return Air Duct Dim. (WidthxHeight) mm 1300x457 1100x560 1300x457 1100x560
High Fan Speed (No. Speeds) R.P.M 900 (3) 900 (3) 900 (3) 900 (3)
Air Flow (At High speed)cfm 3200 2800 3200 2800
m3/h 5440 4760 5440 4760
Net Static Pressure 1 mm H2O 6 8 6 8
Number Of Blowers 2 1 2 1
Fan Type And Model CentrifugalDD 10-10 370W
CentrifugalDD12-12 550W
CentrifugalDD 10-10 370W
CentrifugalDD12-12 550W
Coil
Face Area ft²/ m² 6.42/0.59 6.42/0.59 6.42/0.59 6.42/0.59
Rows Deep 2 4 4 4 4
Fins Spacing Per Inch 12 12 12 12
Net Weight kg 117 120 117 120
I N D O O R U N I T D ATA
O U T D O O R U N I T D ATA
NOTES: 1. Net static pressure available at fan discharge at nominal capacity.2. 6 Rows deep is available on special order.3. Standard unit contain one removable and washable Air Filter. More options are available on special order.4. The unit will contain Capillary tube or Expansion valve as expansion device.
16
CU SERIES Duct Type Split Units
Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CU120
P E R F O R M A N C E
NOTES: 1. Nominal cooling capacity based on indoor air temp. 27ºC DB/19ºC WB and outdoor air temp. 35ºC DB/24º WB 2. Nominal heating capacity based on indoor air temp. 20ºC DB and outdoor air temp. 7ºC DB/6ºC WB3. Operating current at the most loaded phase.
CUE120-A CUE120 - AV
CUC120-V 2xCUC60, 2xCUC60-SQCUC120-TD
OUTDOOR UNIT
INDOOR UNIT
Cooling Capacity 1Btu/h 124500
Watt 36478
Heating Capacity 2Btu/h 127800
Watt 37451
Power Consumption - Cooling / Heating Watt 12943/11523
Operating Current - Cooling / Heating 3 Amp 31/27.5
C.O.P - Cooling / Heating 2.82/3.24
Power Supply V/Ph/Hz 400V, 3Ph, 50Hz
Time Delay Fuse Amp 3x40-C
Condensate Lines - Drain Φ-mm (in) 28 (1-1/8")
* SQ means Super Quiet model
17Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CUC120-TD CUC120-V 2xCUC-60 2xCUC-60-SQ
Dimensions (LxDxH) mm 1750x830x1350 1750x500x1650 1650x500x730 1650x500x730
Air Flow (At High Speed)cfm 10600 12000 5000 4000
m3/h 18020 20400 8500 6800
Noise Level dBA 64 64 57 50
No./Axial Fan Diameter mm 2/630 2/630 2× 2/550 2× 2/550
Outdoor Fan Motor kW 0.66 0.66 0.3 0.2
Speed (High) R.P.M 900 900 900 700
Coil
Face Area ft²/ m² 19.75/1.83 18.4/1.7 2× (9.2/0.85) 2× (10.4/0.96)
Rows Deep 3 3 3 3
Fins Spacing Per Inch 10 12 12 12
Net Weight kg 283 306 2×150 2×150
Model CUE120-A CUE120-AV
Dimensions (LxDxH) mm 1600x800x560 1600x650x1120
Supply Air Duct Dim. (A, B, C) mm 345, 400, 1190 345, 400, 1190
Return Air Duct Dim. (WidthxHeight) mm 1400x533 1400x533
High Fan Speed (No. Speeds) R.P.M 900 (3) 900 (3)
Air Flow (At High speed)cfm 4000 4000
m3/h 6800 6800
Net Static Pressure 1 mm H2O 8 8
Number Of Blowers 2 2
Fan Type And Model CentrifugalDD 12-12 550W
CentrifugalDD 12-12 550W
Coil
Face Area ft²/ m² 8.07/0.75 8.07/0.75
Rows Deep 2 4 4
Fins Spacing Per Inch 12 12
Net Weight kg 136 136
I N D O O R U N I T D ATA
O U T D O O R U N I T D ATA
NOTES: 1. Net static pressure available at fan discharge at nominal capacity.2. 6 Rows deep is available on special order.3. Standard unit contain one removable and washable Air Filter. More options are available on special order.4. The unit will contain Capillary tube or Expansion valve as expansion device.
18
CU SERIES Duct Type Split Units
Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CU140
P E R F O R M A N C E
NOTES: 1. Nominal cooling capacity based on indoor air temp. 27ºC DB/19ºC WB and outdoor air temp. 35ºC DB/24º WB 2. Nominal heating capacity based on indoor air temp. 20ºC DB and outdoor air temp. 7ºC DB/6ºC WB3. Operating current at the most loaded phase.
CUE140-A CUE140 - AV
CUC140-V 2xCUC 70, 2xCUC 70-SQCUC140-TD
OUTDOOR UNIT
INDOOR UNIT
* SQ means Super Quiet model
Cooling Capacity 1Btu/h 144000
Watt 42200
Heating Capacity 2Btu/h 145400
Watt 43997
Power Consumption - Cooling / Heating Watt 14563/13053
Operating Current - Cooling / Heating 3 Amp 35.5/32
C.O.P - Cooling / Heating 2.95/3.35
Power Supply V/Ph/Hz 400V, 3Ph, 50Hz
Time Delay Fuse Amp 3x50-C
Condensate Lines - Drain Φ-mm (in) 28 (1-1/8")
19Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CUC140-TD CUC140-V 2xCUC-70 2xCUC-70-SQ
Dimensions (LxDxH) mm 1750x830x1350 1750x600x1700 1650x500x830 1650x500x730
Air Flow (At High Speed)cfm 10600 12000 5000 4000
m3/h 18020 20400 8500 6800
Noise Level dBA 64 64 57 50
No./Axial Fan Diameter mm 2/630 2/630 2× 2/550 2× 2/550
Outdoor Fan Motor kW 0.66 0.66 0.3 0.2
Speed (High) R.P.M 900 900 900 700
Coil
Face Area ft²/ m² 21.3/1.97 20.8/1.92 2× (10.4/0.96) 2× (11.9/1.1)
Rows Deep 3 3 3 3
Fins Spacing Per Inch 12 12 12 12
Net Weight kg 305 306 2×150 2×150
Model CUE140-A CUE140-AV
Dimensions (LxDxH) mm 1600x800x660 1600x650x1250
Supply Air Duct Dim. (A, B, C) mm 345, 400, 1190 345, 400, 1190
Return Air Duct Dim. (WidthxHeight) mm 1400x635 1400x635
High Fan Speed (No. Speeds) R.P.M 900 (3) 900 (3)
Air Flow (At High speed)cfm 4800 4800
m3/h 8160 8160
Net Static Pressure 1 mm H2O 8 8
Number Of Blowers 2 2
Fan Type And Model CentrifugalDD 12-12 550W
CentrifugalDD 12-12 550W
Coil
Face Area ft²/ m² 9.51/0.88 9.51/0.88
Rows Deep 2 4 4
Fins Spacing Per Inch 12 12
Net Weight kg 143 143
I N D O O R U N I T D ATA
O U T D O O R U N I T D ATA
NOTES: 1. Net static pressure available at fan discharge at nominal capacity.2. 6 Rows deep is available on special order.3. Standard unit contain one removable and washable Air Filter. More options are available on special order.4. The unit will contain Capillary tube or Expansion valve as expansion device.
20
CU SERIES Duct Type Split Units
Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CU170
P E R F O R M A N C E
NOTES: 1. Nominal cooling capacity based on indoor air temp. 27ºC DB/19ºC WB and outdoor air temp. 35ºC DB/24º WB 2. Nominal heating capacity based on indoor air temp. 20ºC DB and outdoor air temp. 7ºC DB/6ºC WB3. Operating current at the most loaded phase.
CUE170-A CUE170-AV
CUC170-TD, CUC170-TD SQ(2 CONDENSER COILS ON BOTH SIDES)*
OUTDOOR UNIT
INDOOR UNIT
Cooling Capacity 1Btu/h 168000
Watt 49224
Heating Capacity 2Btu/h 171780
Watt 50350
Power Consumption - Cooling / Heating Watt 16345/15285
Operating Current - Cooling / Heating 3 Amp 37.8/34.1
C.O.P - Cooling / Heating 3/3.32
Power Supply V/Ph/Hz 400V, 3Ph, 50Hz
Time Delay Fuse Amp 3x50-C
Condensate Lines - Drain Φ-mm (in) 28 (1-1/8")
* Additional configuration is two outdoor units model CUC-80 and one indoor unit of CUE-170.
* SQ means Super Quiet model
21Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CUC170-TD CUC-170-TD-SQ
Dimensions (LxDxH) mm 1700x1100x1200 1700x1100x1200
Air Flow (At High Speed)cfm 12000 9000
m3/h 20400 15300
Noise Level dBA 65 59
No./Axial Fan Diameter mm 2/630 2/630
Outdoor Fan Motor kW 0.66 0.48
Speed (High) R.P.M 900 700
Coil
Face Area ft²/ m² 23.6/2.19 23.6/2.19
Rows Deep 3 4
Fins Spacing Per Inch 12 12
Net Weight kg 370 370
Model CUE170-A CUE170-AV
Dimensions (LxDxH) mm 1500x800x850 1500x650x1400
Supply Air Duct Dim. (A, B, C) mm 345, 400, 1190 345, 400, 1190
Return Air Duct Dim. (WidthxHeight) mm 1300x914 1300x914
High Fan Speed (No. Speeds) R.P.M 900 (1) 900 (1)
Air Flow (At High speed)cfm 5600 5600
m3/h 9520 9520
Net Static Pressure 1 mm H2O 6 6
Number Of Blowers 2 2
Fan Type And Model CentrifugalDD 12-12 736W
CentrifugalDD 12-12 736W
Coil
Face Area ft²/ m² 11.06/1.02 11.06/1.02
Rows Deep 2 4 4
Fins Spacing Per Inch 12 12
Net Weight kg 250 255
I N D O O R U N I T D ATA
O U T D O O R U N I T D ATA
NOTES: 1. Net static pressure available at fan discharge at nominal capacity.2. 6 Rows deep is available on special order.3. Standard unit contain one removable and washable Air Filter. More options are available on special order.4. The unit will contain Capillary tube or Expansion valve as expansion device.
22
CU SERIES Duct Type Split Units
Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CU200
P E R F O R M A N C E
NOTES: 1. Nominal cooling capacity based on indoor air temp. 27ºC DB/19ºC WB and outdoor air temp. 35ºC DB/24º WB 2. Nominal heating capacity based on indoor air temp. 20ºC DB and outdoor air temp. 7ºC DB/6ºC WB3. Operating current at the most loaded phase.
CUE200-A CUE200-AV
OUTDOOR UNIT
INDOOR UNIT
Cooling Capacity 1Btu/h 199000
Watt 58320
Heating Capacity 2Btu/h 202000
Watt 59200
Power Consumption - Cooling / Heating Watt 19640/18100
Operating Current - Cooling / Heating 3 Amp 38.4/33
C.O.P - Cooling / Heating 2.96/3.3
Power Supply V/Ph/Hz 400V, 3Ph, 50Hz
Time Delay Fuse Amp 3x50-C
Condensate Lines - Drain Φ-mm (in) 28 (1-1/8")
CUC200-TD(2 CONDENSER COILS ON BOTH SIDES)*
* Additional configuration is two outdoor units model CUC-100 and one indoor unit of CUE-200.
23Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
Model CUC-200 TD
Dimensions (LxDxH) mm 1700x1100x1200
Air Flow (At High Speed)cfm 14000
m3/h 23800
Noise Level dBA 72
No./Axial Fan Diameter mm 2/710
Outdoor Fan Motor kW 2
Speed (High) R.P.M 900
Coil
Face Area ft²/ m² 23.6/2.19
Rows Deep 4
Fins Spacing Per Inch 12
Net Weight kg 410
Model CUE200-A CUE200-AV
Dimensions (LxDxH) mm 1500x800x950 1500x650x1500
Supply Air Duct Dim. (A, B, C) mm 345, 400, 1190 345, 400, 1190
Return Air Duct Dim. (WidthxHeight) mm 1300x914 1300x914
High Fan Speed (No. Speeds) R.P.M 900 (1) 900 (1)
Air Flow (At High speed)
cfm 6000 6000
m3/h 10200 10200
Net Static Pressure 1 mm H2O 6 6
Number Of Blowers 2 2
Fan Type And Model CentrifugalDD 12-12 1000W
CentrifugalDD 12-12 1000W
Coil
Face Area ft²/ m² 16.2/1.5 16.2/1.5
Rows Deep 6 6
Fins Spacing Per Inch 12 12
Net Weight kg 280 290
I N D O O R U N I T D ATA
O U T D O O R U N I T D ATA
NOTES: 1. Net static pressure available at fan discharge at nominal capacity.2. Standard unit contain one removable and washable Air Filter. More options are available on special order.3. The unit will contain Capillary tube or Expansion valve as expansion device.
24Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
R E C O M M E N D E D H E AT I N G E L E M E N T S F O R C U U N I T S :
* Nominal current presented is for Cooling or Heating, the highest.
ModelCooling Capacity (Btu/hr)
Cooling/Heating CUC+CUE Without Heating Element Recommended
Heating Element (kW)
Heating With Heating Element
Working Current (A)*
Time Delay Fuse (A)
Working Current (A)
Time Delay Fuse (A)
CU60 63,000 12.7 3X20-C 9 15.2 3X16-C
CU70 72,000 14.7 3X25-C 9 17.6 3X20-C
CU80 84,000 17.5 3X25-C 10 19.1 3X20-C
CU100 103,000 20.0 3X32-C 12 23.9 3X25-C
CU120 124,500 31.0 3X40-C 15 31.2 3X40-C
CU140 147,000 35.5 3X50-C 15 31.2 3X40-C
CU170 168,000 37.8 3X50-C 20 38.5 3X40-C
CU200 199,000 38.4 3X50-C 24 38.0 3X40-C
25Product specifications are subject to change without notice.Appearance of products may differ slightly from catalog images.
R E C O M M E N D E D R E F R I G E R A N T T U B E D I A M E T E R B E T W E E N I N D O O R A N D O U T D O O R U N I T S ( I N C H )
Model Cooling Capacity(Ton Refrigeration)
Refrigerant Line
Distance Between Indoor-Outdoor Units (meter)
Up to 10m Up to 20m Up to 30m Up to 40m Up to 50m
CU60 5Liquid Line 1/2'' 1/2'' 1/2'' 1/2'' 1/2''
Suction Line 7/8'' 7/8'' 7/8'' 1-1/8'' 1-1/8''
CU70 6Liquid Line 1/2'' 1/2'' 1/2'' 1/2'' 1/2''
Suction Line 7/8'' 7/8'' 1-1/8'' 1-1/8'' 1-1/8''
CU80 7Liquid Line 1/2'' 1/2'' 1/2'' 1/2'' 5/8''
Suction Line 7/8'' 7/8'' 1-1/8'' 1-1/8'' 1-1/8''
CU100 8Liquid Line 1/2'' 1/2'' 1/2'' 5/8'' 5/8''
Suction Line 7/8'' 1-1/8'' 1-1/8'' 1-1/8'' 1-1/8''
CU120 10Liquid Line 1/2'' 1/2'' 5/8'' 5/8'' 5/8''
Suction Line 1-1/8'' 1-1/8'' 1-1/8'' 1-3/8'' 1-3/8''
CU140 12Liquid Line 5/8'' 5/8'' 5/8'' 5/8'' 5/8''
Suction Line 1-1/8'' 1-1/8'' 1-3/8'' 1-3/8'' 1-3/8''
CU170 14Liquid Line 5/8'' 5/8'' 5/8'' 5/8'' 5/8''
Suction Line 1-1/8'' 1-1/8'' 1-3/8'' 1-3/8'' 1-3/8''
CU200 16Liquid Line 5/8'' 5/8'' 5/8'' 3/4'' 3/4''
Suction Line 1-1/8'' 1-1/8'' 1-3/8'' 1-3/8'' 1-3/8''
• Presented information refers to Refrigerant R410A.• Tube diameter calculation include tube length and rough estimation of local pressure drop along tube elements.• For tube longer than 20 m, an Oil Separator is required.• For Heat Pump systems with tube longer than 20 m, expansion valve should be installed in both Indoor and Outdoor units along with non-return valves.• Standard Vertical height between Indoor and Outdoor units is up to 6 m.• Maximum Vertical height between Indoor and Outdoor units is 15 m. Oil traps should be added along the tube every 3-4 m.• When installing a system with long distance between Indoor and Outdoor units, we recommend ordering special Outdoor unit that include oil-level sight glass.