I0020002.DOC ©Copyright Conveyor Components Co. 2003 1 OF 2 CONVEYOR COMPONENTS COMPANY 130 Seltzer Road, PO Box 167 Croswell, MI 48422 USA PHONE: (810) 679-4211 TOLL FREE (800) 233-3233 FAX: (810) 679-4510 Email: [email protected] http://www.conveyorcomponents.com MODELS CT-100, CT-101 AND CT-102, CT-200 AND CT-201 Figure1: DIMENSIONS CONTROL UNIT SPECIFICATIONS: Input Supply Voltage: 115 VAC @ 50/60 Hz Power Consumption: 10 Watts Probe Voltage Output: 15 VDC Output Relay: DP/DT 10 Amp Resistive @ 115 VAC 5 Amp Resistive @ 230 VAC Time Delay: 0.1 to 10 Seconds. This adjustment will delay output relay action. Enclosure: CT-100: NEMA 12 CT-101: NEMA 4; CT-101F: NEMA4X CT-102: Panel mounting with no enclosure Indicator Lights: 18 V Bayonet base Normal (blue): Light on when relay is energized. Alarm (red): Light on when relay is de-energized. Logic Selector: This jumper determines when the output relay actuates and deactuates. The following summarizes the operation with the jumper at each position. Position 1: Relay energizes when the probe is in the vertical position. Relay de-energizes when probe is in the tilted position. Position 2: Relay energizes when probe is in the tilted position. Relay de-energizes when probe is in vertical position. PROBE SPECIFICATIONS: Standard heavy-duty Steel probe model CT-201 is 9” long. Compact Steel probe model CT-200 is 6” long Each probe contains one SP/ST, normally closed, mercury switch. Probes are available in optional Stainless Steel model CT-201S (9") and model CT-200S (6") Probes with a paddle for use in applications where the materials are moving. Probe signal voltage: 15 VDC Probe actuation angle: 15° from vertical ® CT-100/101 CONTROL UNIT CT-200 COMPACT PROBE CT-201 COMPACT PROBE CT-200P COMPACT PROBE WITH OPTIONAL PADDEL WELDED TO BOTTOM

description

ds

Transcript of CT_MANUAL

Page 1: CT_MANUAL

I0020002.DOC ©Copyright Conveyor Components Co. 2003 1 OF 2

CONVEYOR COMPONENTS COMPANY130 Seltzer Road, PO Box 167 • Croswell, MI 48422 USA

PHONE: (810) 679-4211 • TOLL FREE (800) 233-3233 • FAX: (810) 679-4510Email: [email protected] • http://www.conveyorcomponents.com

MODELS CT-100, CT-101 AND CT-102, CT-200 AND CT-201

Figure1: DIMENSIONS

CONTROL UNIT SPECIFICATIONS:Input Supply Voltage: 115 VAC @ 50/60 HzPower Consumption: 10 WattsProbe Voltage Output: 15 VDCOutput Relay: DP/DT

10 Amp Resistive @ 115 VAC5 Amp Resistive @ 230 VAC

Time Delay: 0.1 to 10 Seconds. This adjustment will delay output relay action.Enclosure: CT-100: NEMA 12

CT-101: NEMA 4; CT-101F: NEMA4X CT-102: Panel mounting with no enclosure

Indicator Lights: 18 V Bayonet baseNormal (blue): Light on when relay is energized.Alarm (red): Light on when relay is de-energized.

Logic Selector: This jumper determines when the output relay actuates and deactuates.The following summarizes the operation with the jumper at eachposition.

Position 1: Relay energizes when the probe is in the vertical position.Relay de-energizes when probe is in the tilted position.

Position 2: Relay energizes when probe is in the tilted position.Relay de-energizes when probe is in vertical position.

PROBE SPECIFICATIONS:Standard heavy-duty Steel probe model CT-201 is 9” long.Compact Steel probe model CT-200 is 6” longEach probe contains one SP/ST, normally closed, mercury switch.Probes are available in optional Stainless Steel model CT-201S (9") and model CT-200S (6")Probes with a paddle for use in applications where the materials are moving.Probe signal voltage: 15 VDCProbe actuation angle: 15° from vertical

®

CT-100/101 CONTROL UNIT

CT-200COMPACT PROBE

CT-201COMPACT PROBE

CT-200PCOMPACT PROBE WITH OPTIONAL

PADDEL WELDED TO BOTTOM

Hugo
Line
Hugo
Line
Page 2: CT_MANUAL

I0020002.DOC ©Copyright Conveyor Components Co. 2003 2 OF 2

Figure 2: CONTROL UNIT CIRCUIT

INSTALLATION INSTRUCTIONS:

MOUNTING: The control unit should be mounted in an area free from vibration and the temperatureshould not exceed 125° F. Consideration should be given to mounting the unit whereindicator lights will be visible to the necessary personnel, and wiring may be easilyinstalled to the probe and other machinery.

WIRING: All wiring should be in compliance with applicable Local, Federal, and State codes.Probe connection cable is 16-2 type SO and is attached to the probe. Length is suppliedas specified per order (probe cable may be spliced).

PROBE INSTALLATION:The probe should be suspended using a fixed support at a position where it will easilyintercept the bulk material at the desired indication point. There must be a free flow ofmaterial both to and away from the probe. In some installations, it is necessary to install abaffle or shield above the probe assembly to protect it from product surges.

Figure3: TYPICAL INSTALLATIONS

TIME DELAY ADJUSTMENTCW = INCREASECCW = DECREASE

LOGIC SELECTIONSWITCH