CT_MANUAL
-
Upload
wilmanzito -
Category
Documents
-
view
2 -
download
0
description
Transcript of CT_MANUAL
I0020002.DOC ©Copyright Conveyor Components Co. 2003 1 OF 2
CONVEYOR COMPONENTS COMPANY130 Seltzer Road, PO Box 167 • Croswell, MI 48422 USA
PHONE: (810) 679-4211 • TOLL FREE (800) 233-3233 • FAX: (810) 679-4510Email: [email protected] • http://www.conveyorcomponents.com
MODELS CT-100, CT-101 AND CT-102, CT-200 AND CT-201
Figure1: DIMENSIONS
CONTROL UNIT SPECIFICATIONS:Input Supply Voltage: 115 VAC @ 50/60 HzPower Consumption: 10 WattsProbe Voltage Output: 15 VDCOutput Relay: DP/DT
10 Amp Resistive @ 115 VAC5 Amp Resistive @ 230 VAC
Time Delay: 0.1 to 10 Seconds. This adjustment will delay output relay action.Enclosure: CT-100: NEMA 12
CT-101: NEMA 4; CT-101F: NEMA4X CT-102: Panel mounting with no enclosure
Indicator Lights: 18 V Bayonet baseNormal (blue): Light on when relay is energized.Alarm (red): Light on when relay is de-energized.
Logic Selector: This jumper determines when the output relay actuates and deactuates.The following summarizes the operation with the jumper at eachposition.
Position 1: Relay energizes when the probe is in the vertical position.Relay de-energizes when probe is in the tilted position.
Position 2: Relay energizes when probe is in the tilted position.Relay de-energizes when probe is in vertical position.
PROBE SPECIFICATIONS:Standard heavy-duty Steel probe model CT-201 is 9” long.Compact Steel probe model CT-200 is 6” longEach probe contains one SP/ST, normally closed, mercury switch.Probes are available in optional Stainless Steel model CT-201S (9") and model CT-200S (6")Probes with a paddle for use in applications where the materials are moving.Probe signal voltage: 15 VDCProbe actuation angle: 15° from vertical
®
CT-100/101 CONTROL UNIT
CT-200COMPACT PROBE
CT-201COMPACT PROBE
CT-200PCOMPACT PROBE WITH OPTIONAL
PADDEL WELDED TO BOTTOM
I0020002.DOC ©Copyright Conveyor Components Co. 2003 2 OF 2
Figure 2: CONTROL UNIT CIRCUIT
INSTALLATION INSTRUCTIONS:
MOUNTING: The control unit should be mounted in an area free from vibration and the temperatureshould not exceed 125° F. Consideration should be given to mounting the unit whereindicator lights will be visible to the necessary personnel, and wiring may be easilyinstalled to the probe and other machinery.
WIRING: All wiring should be in compliance with applicable Local, Federal, and State codes.Probe connection cable is 16-2 type SO and is attached to the probe. Length is suppliedas specified per order (probe cable may be spliced).
PROBE INSTALLATION:The probe should be suspended using a fixed support at a position where it will easilyintercept the bulk material at the desired indication point. There must be a free flow ofmaterial both to and away from the probe. In some installations, it is necessary to install abaffle or shield above the probe assembly to protect it from product surges.
Figure3: TYPICAL INSTALLATIONS
TIME DELAY ADJUSTMENTCW = INCREASECCW = DECREASE
LOGIC SELECTIONSWITCH