CSBC_Specification Guide_2010.10.pdf
Transcript of CSBC_Specification Guide_2010.10.pdf
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
1/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page1
Box 746509, Arvada, Colorado 80006 USA
(303) 953-3250 phone (303) 953-3251 fax
www.canamsteelbuildings.com
SpecificationGuideNotice:Duetoongoingproductimprovement,allinformationhereinissubjecttochangewithoutnotice.
CONTENTS
Section1:
Section2:
Section3:
Section4:
Section5:
Section6:
Section7:
Section8:
Section9
Section10:
Section11:
General
StructuralDesign
AnchorageandFoundations
Submittals
StructuralFraming
RoofCovering PBRpanel
RoofCovering SSRpanel,Trapezoidal
WallCovering
Accessories
StandardServiceabilityCriteria
Execution
Section1. General
1.1. Scope
1.1.1. Thesespecificationsareanoutlineofperformancetoensure thatthearchitect,engineer,builder,buyerand/orbuyersagentunderstandsthebasisfordesign,manufacture,andapplicationofallCanamSteelBuildingCorporationmetalbuildingsystems.
1.1.2. Duetoongoingproductimprovement,allinformationhereinissubjecttochangewithoutnotice.
1.1.3
The
building
shall
consist
of
all
primary
and
secondary
structural
members,
connection
bolts, canopies, roof extensions, sheeting, trim, flashing, doors, fasteners, gutters,downspouts,andothermiscellaneousitemsandaccessoriesasspecified,shown,orcalledforinCanamSteelBuildingCorporations'orderdocumentsordrawings. Refertothe2006Edition of the Metal Building Systems Manual section entitled Common IndustryPracticesforthestandards inwhichthisguidewillbeused. CSBCwillnotprovide itemsnotspecificallycalledforintheCSBCorderdocuments.
1.2. DimensionalTerminology
1.2.1. Width The building width shall be the distance from outside face of sidewall girt tooutsidefaceofsidewallgirt(steellinetosteelline).
1.2.2.
Length
The
building
length
shall
be
the
distance
from
outside
face
of
endwall
girt
to
outsidefaceofendwallgirt(steellinetosteelline).
1.2.3. EaveHeightThebuildingeaveheightshallbethedistancefromfinishedfloortotopofeave strut or eave purlin at the steel line. For buildings which are to be placed atopconcrete curbs or stem walls, or where column base plates are to be recessed belowfinishedfloor,eaveheightshallstillbemeasuredfromthefinishedfloorelevation.
1.2.4. BaySpacingThebayspacingshallbethedistancefromcenterlineofprimaryframetocenterlineofprimaryframeforinteriorbays. Endbayspacingshallbethedistancefromoutsidefaceofendwallgirt(steelline)tocenterlineoffirstinteriorprimaryframe.
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
2/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page2
1.2.5. ModuleSpacingThemodulespacingonmultispanbuildingsshallbethedistancefromoutsidefaceofsidewallgirt(steelline)tocenterlineoffirstinteriorcolumn. Itisalsothedistance from centerline of interior column to centerline of interior column for interiorspans.
1.2.6. RoofSlopeTheroofslopeshallbebasedonanorderspecifiedverticalriseforeach12"horizontalrununlessotherwisestated.
1.3. BuildingTypes
1.3.1.
Solid
web
framing
consists
of
members
fabricated
from
shopwelded,
hot
rolled
steel
sheetsorplatesandhotrolledflatbars.
1.3.1.1. Rigid Frame (RF) buildings are clearspan buildings with tapered sidewall columns. Theyarecommonlyusedforclearspansfrom30feettoover300feet(9.14mto91.4m)wide.
1.3.1.2. Tapered Beam (TB) buildings are clearspan buildings with straight sidewall columns andhorizontalbottomflangerafters. TBbuildingsaresuitableforsmallerclearspanbuildingsfrom20feetto60feet(6.1mto18.29m)wide.
1.3.1.3. RigidFramewithinteriorcolumns(RFMS)buildingsaremultispanbuildingswithinteriorcolumns. RFMSbuildingsprovideaneconomicaladvantageonbuildingsfrom80feettoover500feet(24.38mto152.4m)wide.
1.3.1.4.
Singleslope
clearspan
(SS)
or
multi
span
(SS
MS)
buildings
are
available
in
width
ranges
similartoRFandRFMSaspreviouslylisted. Roofslopeisinasingledirectiontothelowsidewall.
1.3.1.5. Leanto (LT) or Leanto with interior columns (LTMS) buildings are similar to the SSbuildingbutwiththehighsidecolumnbeingeliminated. TheLTrafterissupportedbytheparentbuildingframe,sidewall,orendwallcolumn.
Section2. StructuralDesign
2.1. DesignCriteria
2.1.1. All structural steel sections and welded plate members shall be designed in accordance
with
the
Manual
of
Steel
Construction,
13th
Edition,
American
Institute
of
Steel
Construction, Chicago, IL; and the latest edition of the Structural Welding Code Steel,ANSI/AWSD1.1,AmericanWeldingSociety
2.1.2. All lightgagecoldformedstructuralmembersandexteriorcoveringshallbedesigned inaccordancewiththeColdFormedSteelDesignManual,2002Edition,American IronandSteelInstitute. Allstandardsfortheweldingofcoldformedmembersarebaseduponthelatest edition of the Structural Welding Code Sheet Steel, ANSI/AWS D1.3, AmericanWeldingSociety.
2.1.3. Theprimaryandsecondaryframingandcoveringshallbedesignedforallapplicableloadsandcombinationsofloadsassetforthin:
2.1.3.1. Thespecifiedgoverningbuildingcodefortheorderunderconsideration. Thismaybeany
ofthe
standard
model
building
codes
currently
published,
such
as:
the
International
Code
Councils International Building Code (IBC) or the National Research Council CanadasNational Building Code (NBC). Additionally, many orders may be within states,municipalitiesorprovincesthathavetheirownamendmentstothegoverningmodelcodeorthathavetheirownindependentcode. Inthiscase,loads,deflectioncriteria,andloadcombinations will be determined in accordance with this governing local code.Specificationof loadsandcodesanddesignresponsibilityshallbeasstated inArticle IV,Common Industry Practices,of the 2006Edition of the MetalBuildingSystems ManualfromMBMA. Thesecommon industrypracticeswillapplyregardlessofthestate, local,provinceormodelcodechosen.
2.1.3.2. Inlieuofappropriatestate,local,province ormodelcodes,ArticleI.,LoadApplication of
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
3/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page3
the 2006 Edition of the Metal Building Systems Manual from MBMA shall be used todetermineloadsandloadcombinations.
2.1.3.3. Design loadsshallnotbe lessthanthosespecified inArticle IXentitled Wind,SnowandRainDataByCounty,oftheMetalBuildingSystemsManual,MBMA,2006Edition,ifthereisnotacontrollingstateorlocalcode. IfthecontrollingstateorlocalcodespecifiesvaluesthatarelessthanthosefoundinArticleIX,thestateorlocalcodetakesprecedence.
2.1.3.4. Theappropriategoverningcodeshallbespecifiedatthetimeofthebuildingquotation.
2.2.
EngineeringCertifications
2.2.1. Allbuildingsshallbedesignedbyorunderthedirectsupervisionofregisteredprofessionalengineers in accordance with the information specified to Canam Steel BuildingCorporation intheorderdocumentation incompliancewithArticleIV,Common IndustryPractices,ofthe2006EditionoftheMBMAMetalBuildingSystemsManual. ThesealingengineerisnottheEngineerofRecordfortheprojectandcannotbeconstruedassuch.
2.2.2. Designcalculations,certifiedbyaprofessionalengineer,maybepurchasedwiththeorder,ifrequested.
2.2.3. A letter of certification, certified by a professional engineer, may be supplied with thebuildingquoteproposal, ifrequested. A letterofcertificationshallbeprovidedwiththeorderatthetimetheanchorrodplansarecomplete.
2.2.4. Allpermitdrawingsshallbearthesealed ofaregisteredprofessionalengineerlicensedtopractice inthestateorprovincewherethebuilding istobe located. Approvaldrawingswillnotbesealed. Erectiondrawingswillbesealedonly ifspecificallyrequestedby thecustomer.
2.3. AuxiliaryDesignLoads
2.3.1. Crane and impact loads shall be applied in accordance with the Manual of SteelConstruction,13thEdition,AmericanInstituteofSteelConstruction,Chicago,IL,ArticleII,of the 2006 Edition of the MBMA Metal Building Systems Manual; and the appropriatecodespecifiedintheCSBCorderdocuments.
2.3.2.
Seismic
loads,
for
buildings
in
areas
subject
to
earthquakes,
shall
be
derived
using
the
proceduresetforthbyappropriatebuildingcodesspecifiedintheCSBCorderdocuments.
2.4. LoadCombinations
2.4.1. Load combinations shall be per the appropriate building code. In lieu of any specifiedcode,loadsshallbecombinedperArticleI,Section1.3.7ofthe2006EditionoftheMBMAMetalBuildingSystemsManual.
Section3. AnchorageandFoundations
3.1. AnchorRods
3.1.1. Anchorrodsandbaseplatesshallbedesigned toresistallcolumnreactions. Sizesused
shall
be
as
those
shown
on
Manufacturers
drawings.
The
length
and
embedmentanchorageofallanchorrodsshallbetheresponsibilityofthefoundationengineer.
3.1.2. Anchor rodsshall not be suppliedby Canam Steel BuildingCorporation andshallbe theresponsibilityofthecontractororerectortofurnish,unlessspecificallynotedotherwiseintheCSBCorderdocuments.
3.1.3. Leveling plates shall not be supplied by Canam Steel Building Corporation unlessspecificallycalledforintheCSBCorderdocuments.
3.2. Foundations
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
4/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page4
3.2.1. Foundations shall be designed by a qualified registered professional engineer toaccommodate the local soil conditions and meet building reaction requirements inadditiontootherloadsimposedbybuildinguseoroccupancy. Itshallbetheresponsibilityof the Engineer of Record to verify that the loading criteria defined on the OrderDocumentsisadequateforthelocationoftheprojectinquestion.
3.2.2. NeitherthefoundationdesignnorthereinforcingsteelshallbesuppliedbyCanamSteelBuildingCorporation. Itshallbetheresponsibilityofthecustomer,contractor,orerectortoobtaintheseitems.
Section4.
Submittals
4.1. General
4.1.1. Canam Steel Building Corporation shall supply on all orders three sets of anchor roddrawings and reactions. Additional sets of anchor rod drawing and reactions may bepurchasedatadditionalcost.
4.1.2. Canam Steel Building Corporation shall supply on all orders three sets of final erectiondrawings. Additionalsetsoffinalerectionsdrawingsmaybepurchasedatadditionalcost.
4.1.3. When called for in the order documents, Canam Steel Building Corporation shall supplythreesetsofpermitdrawingsshowingengineeringdesigndetails,criticalclearances,keyconnection details, material specifications, and lateral load resisting elements such asbracing,
diaphragm,
and
shearwall
layouts.
4.1.4. When called for in the order documents, Canam Steel Building Corporation shall supplythree sets of approval drawings. Approval drawings shall show building layout, criticalclearances,criticaldetails,andmayincludepermitdrawinginformationifrequested. Finalfabrication will not begin until approval drawings have been returned with appropriatereleasesignaturesorappropriateinstructionhasbeengiventoCSBCtoreleasetheprojectusingaChangeOrder.
4.1.5. CanamSteelBuildingCorporation doesnotsupplyshopfabricationdrawingsforrevieworapproval. AsbuiltdrawingsarenotprovidedbyCSBC.
4.1.6. UnlessspecificallycalledforintheCanamSteelBuildingCorporationorderdocuments,all
drawings
shall
be
issued
either
electronically
or
on
11
x
17
paper
stock.
Larger
size
drawingsmaybeavailableatanadditionalcost.
Section5. StructuralFraming
5.1. General
5.1.1. Theterms primarystructural or primaryframing shallrefertoanybuiltup,hotrolled,or coldform columns or framing systems which transfer their loads directly to thestructuresfoundation.
5.1.2. Thetermssecondarystructural orsecondaryframing shallrefertoanycoldform,hotrolled,orbuiltuppurlins,girts,struts,bracing,orbeamswhichtransfertheir loads fromthecladdingtotheprimarystructuralmemberorframingtowhichtheyattach.
5.1.3. Unlessotherwisespecified intheCanamSteelBuildingCorporationorderdocuments,theminimumstandarddesignthicknessofstructuralframingmembersshallbeasfollows:
Websofweldedbuiltupmembers 0.125(3.175mm)Flangesofweldedbuiltupmembers 0.175(4.445mm)Coldformedsecondaryframingmembers 0.060(1.524mm)Cablebracing 0.250(6.35mm)/Rodbracing 0.625(15.875mm)Anglebracing 0.1875(4.762mm)
5.1.4. All hotrolled sheet, plate, and strip steelused in webs from 0.125 to 0.175 (3.175 to4.445mm)thickshallconformtotheprovisionsofASTMA1011SSGrade55(55,000psiminimumyieldstrength). Allthicknessesgreaterthan0.175(3.175mm)shallconformto
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
5/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page5
ASTMA572Grade55(55,000ksiminimumyield).5.1.5. All hotrolled flat bars used in flanges shall conform to the provisions of ASTM A572
Grade55,withminimumyieldof55,000psi.
5.1.6. All wideflange, channel, and S shapes shall conform to the provisions of ASTM A36,ASTMA572orASTMA992(Wshapeonly). AlltubeandpipeshapesshallconformtoASTMA500,GradeB.
5.1.7. Allhotrolledorcoldrolledsheetandstripsteel lessthan0.150"(3.81mm) thickusedinfabricationofcoldformedstructuralmembersshallbeofASTMA1011,Grade55(55,000
psiminimum
yield
stress)
or
Grade
55
Mod
57
(57,000
psi
minimum
yield
stress).
5.1.8. Cable used for diagonal bracing shall conform to ASTM A475; coating Class A, GradeExtraHighStrength7wire. ThreadedrodshallmeetASTMA529,Grade50requirements.AnglesectionsshallmeetminimumA36requirements.
5.1.9. Structuralsteelmembersshallbesheared,formed,punched,welded,andpaintedbythemanufacturer. Allshopconnectionsshallbeweldedinconformancewithstandardsbasedupon the current edition of ANSI/AWS D1.1 referenced previously in this guide inParagraph 2.1.1. Welders and welding operators are qualified as provided in this samecode.
5.1.10. All field connections of primary structural members shall be bolted with high strengthbolts and nuts (ASTM A325) and shall be fully tensioned unless otherwise specified.Secondary
structural
members
shall
be
field
bolted
with
ASTM
A307
or
A325
bolt
assembliesascalledforindesign.
5.1.11. Light gage coldformed sections shall be manufactured by roll or brakeforming. AlldimensionsshallbefabricatedtoMBMAtolerances.
5.1.12. Allstructuralframingmembersthatarenotgalvanizedshallbegivenoneshopcoatofaredprimer. Grayprimermaybeavailableatanadditionalcostand,ifavailable,mustbecalled for in the Canam Steel Building Corporation order documents. All surfaces arecleanedof looserust, loosemillscale,andotherforeignmatterbyusing,asaminimum,thehandtoolcleaningmethodSSPCSP21priortopainting. Allpaintedsurfacesaretobereasonablyfreeofexcessivedrips,runs,sags,andcracking. ReferenceMBMA2andAISC3forintendedprimerprotection,propercare,erection,andfunctionofshopprimecoat.
5.1.13. Allframingmembersshallhaveidentifyingmarkstoaidthe erectorintheerectionofthebuilding.
5.2. PrimaryFramingMembers
5.2.1. Rigid frame, sidewall columns, rafter beams, and canopy beams shall be shopwelded,builtup Ishapes. Membersshallbeofconstantdepthor tapered,havingbaseplates,necessaryclips,andspliceplatesforcompletelyfieldboltedassemblyandattachmentofsecondarymembers.
5.2.2. RafterbeamsandendwallcolumnsshallbeeitherbuiltupIshapes,WFshapes,orrollformedCsectionsasrequiredtosatisfyloadandspanrequirements.
5.2.3.
Interiorcolumns
shall
be
round
pipe
sections,
Built
up
I shapes,
hot
rolled
WF or
tube
sectionsasrequiredtosatisfyloadandorderrequirements.
5.3. SecondaryFramingMembers
5.3.1 PurlinsandgirtsshallberollformedZEEorCEEsectionsofadequatesizeandthicknessasdetermined by the design criteria. Purlins and girts shall be either simplespan orcontinuousmembers.
5.3.2. Purlins for longbay building layouts shall typically consist of barjoists designed underSteelJoist Institutespecificationsfortheprescribed loads. Fieldweldingofjoistbridgingandseatsisthestandardmethodforconnectionofjoiststosupportingprimarystructural
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
6/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page6
members.5.3.3. EavestrutsshallberollformedorbrakeformedCEEsections.
5.3.4. Windbracingshallconsistofdiagonalcable, rod,oranglebracing. Adjustment tocablebraces shall be made by an eyebolt assembly. Adjustment to rod bracing may be bythreadedassembly. Anglebracingisnotadjustableandmayrequirefinalfieldwelding.
5.3.5. Flangebracingshallconsistofanglebracingconnectedtothewebofthepurlinorgirtandto the compression flange of the primary structural member. Flange braces shall beattachedtobarjoistsviafieldwelding.
5.3.6. Base support for wall panels shall consist of a continuous base angle, base angle flash,basechannelorbasegirtwhichshallbesecurelyattachedtoconcretebythecontractorusingpowderactuateddrivepins,expansionanchors,orothersimilaranchorage.
Section6. RoofCovering PBRpanel
6.1. General
6.1.1. MinimumrecommendedroofslopeforPBRpanelis1/2"in12".
6.1.2. Maximumrecommendedbuildingwidthis240feet (73.15m)(gable)or120feet(36.58m)(singleslope)forzeepurlinroofs. PBRpanelshallbeusedinconjunctionwithzeeorceepurlins as supports. Joists or roof beams are not acceptable support members unless
specificallyagreed
to
by
the
Engineering
Manager.
6.1.3. PBRpanelin26gaugematerialqualifiesforaUL580Class90upliftrating(Construction#161)whenfixedtoroofpurlinswhicharespacedat5'0"(1.52m)oncenterorless.
6.1.4. PBRpanel in 26 gauge material qualifies for a FM1120 uplift rating when fixed to roofpurlinswhicharespacedat5'0"(1.52m)oncenterorless.
6.2. PanelMaterial
6.2.1. PBRPanelprofileshallbeprecision rollformed from26gaugesteelsheeting. 24gaugemaybeavailableatadditionalcost.
6.2.2. Galvanized steel sheeting shall be processed in accordance with ASTM A653. Consultyour
specific
plant
for
minimum
yield
strength
and
grade
of
material.
The
galvanized
coatingshallbe .90ozpersquarefoot(ClassG90) inaccordancewithASTMA653. ThespangleforgalvanizedpanelisbrightflatspangleinaccordancewithASTMA653.
6.2.3. Galvalumesteelsheetingshallbealuminumzincalloycoatedsteelsheet inaccordancewith ASTM A792. Consult your specific plant for minimum yield strength and grade ofmaterial. Ithasacoatingthicknessof.55ozpersquarefoot.
6.2.4. RoofpanelsprovidedbyCanamSteelBuildingCorporation forexterioruseareprecisionrollformed fromprepaintedG90galvanizedorGalvalumecoils. Coilsto receive finishpaintsaresubjectedtoastrenuouscleaningprocesspriortocoating. Next,thecoilsareprimercoatedandovencured. Thefinishcoat isthenappliedandmonitoredforproperovencure temperatureandcoloruniformity. Finishedmaterial issubjected tostringent
quality
control
tests
including:
physical
bend
and
impact
resistance,
film
thickness,hardness, gloss, and color. This process is time tested and uses the industry proven
modifiedSiliconizedModifiedPolyesterpaintsystem. A70%Kynar500finishisavailableatanadditionalcostuponrequest.
6.3. PanelConfiguration
6.3.1. PBRPanelpanelprovidesa36(915mm)netcoverageandconsistsofmajorribs1 "(32mm)deepspacedat12"(305mm)oncenterwithanextendedpurlinbearingsidelaptoallowforadditionalsidelapsupport. Minorribsreinforcetheflatareabetweenmajorribstominimizeoilcanning.
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
7/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page7
6.4. Fasteners
6.4.1. Roofpaneltosecondary framing fastenershallbea#1214 x11/4 (32mm)selfdrillingcarbonsteelscrew,hexwasherheadwithsealingwasher. Fastenershallhavea20yearcorrosion resistant coating. Fastener shall have a painted head to match panel and/ortrimcolorwhenusedwithpaintedmaterial.
6.4.2. Paneltopanel,flashingtoflashing,(stitch)fastenerforroofshallbea#12x3/4" (19mm)sharppointcarbonsteelscrew,hexwasherheadwithsealingwasher. Fastenershallhavea20yearcorrosionresistantcoating. Fastenershallhaveapaintedheadtomatchpanel
and/ortrim
color
when
used
with
painted
materials.
6.5. TrimandFlashing
6.5.1. Colorcoated trimand flashingshallbe26gauge. Trimshallbeprovidedateave, ridge,rake,andwherevernecessarytoensureaproperlyconstructedbuilding,asdefinedontheCanamSteelBuildingCorporationorderdocuments.
6.5.2. Neither counterflashing for parapet conditions nor tiein flashing to existing buildingsshallbeprovidedbyCanamSteelBuildingCorporation.
6.5.3. All exposed trim and flashing material shall be manufactured from galvanized orGalvalumesteelstrip.
6.5.4.
Exterior
gutters
and
gable
flash
shall
be
manufactured
in
20
(6.1
m)
lengths
wherever
possible.
6.6. Sealants
6.6.1 Mastic for sidelaps, endlaps, and flashing shall be an isobutylene tripolymer rubberpressuresensitivetapemastic.
6.6.2. Tapemasticforsidelapsshallbe3/32" (2.38 mm) thickX1/2"(12.7mm)wideandmasticforendlapsshallbe1/8"(3.18mm)thickX3/4"(19.05mm)wide.
6.6.3. Tubesealantsshallbeofthenonhardeningelastomerictype. Thissealantistobeusedatalltrimandflashingendlaps.
6.7.
Closures
6.7.1. Closuresshallbeclosedcellpolyethylenefoamtomatchthepanelconfiguration.
6.7.2. Closuresshallbeprovidedattheeave endfor roof panels.
6.8. InstallationofPanels
6.8.1. Storage and installation of the roofing system shall be in accordance with Canam SteelBuildingCorporationsprintedinstructions.
6.8.2. All endlaps and sidelaps on roof panels shall be sealed with a continuous row of tapemastictopreventairandwaterfrominfiltratingthebuilding.
6.8.3. Standard maximum panel length shall be 30 (9.14 m). If required, lengthsofup to 45(13.72m)maybeprovided.
6.8.4. Useofcuttingtoolsthatdamagethe panelfinishshallnotbeallowed.
6.8.5. Panelsshallnotbemarkedwithanygraphiteorleadmarkers.
6.9. Cleanup
6.9.1. Roof surface should be cleaned daily during construction of all filings, cuttings, screws,pencilmarkings,anddebristo preventdamageduetooxidationofforeignmaterials.
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
8/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page8
6.9.2. Contractorshallthoroughlycleanallpanels,trim,andguttersofallforeignmaterialuponcompletionofconstruction.
6.10. FieldCuttingofPanels
6.10.1. WhenfieldcuttingormiteringPBRPanels,nonabrasivecuttingtoolssuchasnibblersorsnipsshallbeused. Abrasivecutting toolssuchasmechanicalgrinders,saws,shears,orscissors can damage the Galvalume or painted finish and create excess metal shavingsthat can corrode the panels. The use of nonapproved cutting devices may void yourmanufacturerswarranty.
Section7. RoofCovering StandingSeamRoofSystem, Trapezoidal
7.1. General
7.1.1. Specifically includedarepanels,panelclips,flashing,panelsplices,ridgematerial,andallnecessaryfasteners.
7.1.2. Minimumroofslopeis1/4"in12".
7.1.3. Panels are rated for UL90 uplift rating UL580 when installed to roof support membersspacedaslistedinULConstructionListing#552,supportedbyeitherpurlinsorjoistswhicharespacedat5'0"(1.52m)oncenterorless.
7.1.4.
Panelshave
an
FM1
120
uplift
rating
when
supported
by
either
purlins
or
joists
which
are
spacedat5'0"(1.52m)oncenterorless.
7.2. PanelMaterial
7.2.1. TrapezoidalSSRprofileshallbeprecisionrollformedfrom24gagesteel. Galvalumesteelsheeting is aluminumzinc coated steel alloy coated steel sheet with a minimum yieldstrengthof50ksiinaccordancewithASTMA792,Grade50. Ithasacoatingthicknessof.55oz.persquarefoot.
7.2.2. RoofpanelsprovidedbyCanamSteelBuildingCorporation forexterioruseareprecisionrollformedfromprepaintedGalvalumecoils. Coilstoreceivefinishpaintsaresubjectedto a strenuous cleaning process prior to coating. Next, the coils are prime coated andoven cured. The finish coat is then applied and monitored for proper ovencuretemperature
and
color
uniformity.
Finished
material
is
subjected
to
stringent
quality
control tests including: physical bend and impact resistance, film thickness, hardness,gloss, and color. This process is time tested and uses the industry proven modifiedSiliconized Modified Polyester paint system. A 70% Kynar 500 finish is available atadditional cost upon request. Trapezoidal SSR roof accessories (end dams, cinch straps,gutterbrackets)areprovidedasunpainted.
7.2.3. Panelshallbefactorypunchedandnotchedatridge,highside,andlaplocations.
7.2.4. PanelsidelapsshallhavefactoryappliednonskinningButylmastic.
7.3. PanelConfiguration
7.3.1.
Panelsshall
have
3
(76.2
mm)
trapezoidal
ribs
spaced
24
(609.6
mm)
on
center.
Minor
ribsreinforcetheflatareabetweenmajorribstominimizeoilcanning.
7.4. PanelClip&Fasteners
7.4.1. Fixedpanelclipsshallonlybeusedwithpanelrunsof lessthan120(36.58m). Floatingpanelclipsshallbeusedup toa250 (76.2m)panelrunandshallbeselfcenteringandallow forupto11/2 (38.1mm)expansionand/orcontractionoftotalmovement fromthe centered position. The clip design shall insure that movement does not occurbetweenthepanelandclip.
7.4.2. Thepanelclipsshallhavefactoryappliedmastictoinsureaweathertightinstallation.
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
9/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page9
7.4.3. Eachclipshallbeattachedtothejoistorpurlinwithtwofasteners. Sizeandtypewillberecommended by Canam Steel Building Corporation for the specific application. ClipfastenersforretrofitapplicationsarenotbyCSBCandmustbespecifiedbytheBuyerorBuyersAgent.
7.4.4. Panelendlapfastenersshallbea#17 x11/4"(32mm) selftappingcarbonsteelscrew,hexwasherhead. Fastenershallhavea20yearcorrosionresistantcoating.
7.5. TrimandFlashing
7.5.1.
Colorcoated
trim
and
flashing
shall
be
26 gauge.
Trim
shall
be
provided
at
eave,
ridge,
rake,andwherenecessarytoensureaproperlyconstructedbuilding.
7.5.2. Higheaveflashingandflashingparalleltotheroofpanelsshallaccommodatethethermalexpansion and contraction of the roof without damage to the roof panels or flashing.CounterflashingforparapetconditionsandflashtoexistingbuildingsarenotprovidedbyCanamSteelBuildingCorporation.
7.5.3. All exposed trim and flashing material shall be manufactured from galvanized orGalvalumesteelstrip.
7.5.4. Exterior gutters and gable flash shall typically be manufactured in 20' (6.07 m) lengthswherepossible.
7.6.
Installation
7.6.1. Storage and installation of the roofing system shall be in accordance with Canam SteelBuildingCorporationsprintedinstructions.
7.6.2. TheTrapezoidalSSRhandcrimper isspeciallydesigned forusewith theTrapezoidalSSRroof. Undernocircumstancesshallthehandcrimperbeusedonanyothermanufacturersroofsystem. Additionally,undernocircumstances isanothermanufacturerscrimpertobe used on theTrapezoidalSSR roofeven ifpanelsappear to be the same. Permanentdamagetotheseamand/orthepanelfinishmayoccuriftheTrapezoidalSSRcrimpingtoolisnotusedandshallvoidallwarranties.
7.6.3. Thepanelspliceshallhavea0.060galvanizedsteelbackupplateanda0.090aluminum
cinch
strap.
7.6.4. Thebackupplateandcinchstrapshallbefactorypunchedtoensureproperfit.
7.6.5. Panelspliceshallbesealedwith tapemastic.
7.6.6. Standardmaximumpanellengthshallbe550 (16.76m).
7.6.7. Theuseofcuttingtoolsthatdamagethepanelfinishshallnotbeallowed.
7.6.8. Panelsshallnotbemarkedwithanygraphiteorlead markers.
7.7. Cleanup
7.7.1.
Roof
surface
should
be
cleaned
daily
during
construction
of
all
filings,
cuttings,
screws,
pencilmarkings,anddebristopreventdamageduetooxidationofforeignmaterials.
7.7.2. Contractorshallthoroughlyclean allpanels,trim,andguttersofallforeignmaterialuponcompletionofconstruction.
7.8. Maintenance
7.8.1. Theownershallkeeptherooffreeandcleanofdebrisandcorrosivematerialsatalltimes.
7.8.2. Guttersanddownspoutsshallbecleanedperiodicallyandkeptfreeflowingatalltimes.
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
10/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page10
7.8.3. Flashingandsheetinginterfacesshallbeinspectedyearlytoensureproperconnectionandwatertightness.
7.8.4. Endlaps,eaves, ridges,curbs, translucentpanels,andother interfacesshallbe inspectedandmaintainedyearly. Normaladjustmentsortighteningoffastenersmayberequired.
7.8.5. Theuseoftarandothertopicalappliedproductsshallnotbepermittedunlessspecifiedbythemanufacturer.
7.8.6. Copper,leadflashing,exposediron,ordebrisshallnotbepermittedontheroof.
7.8.7. Pipes to and supports for roofsupported units shall be of a noncorrosive or rustfreematerial. Field painting of pipes and supports may be required to resist corrosion.Condensationfromrooftopunitsshallbepipedtointeriororexteriorlocations. Damageduetocondensatewaterisnotcoveredundermanufacturerswarranty.
7.9. ErectionSequence
7.9.1. TheTrapezoidalSSRroofsystemisdesignedtobeerectedstartingfromeitherendofthebuilding. Insomecases,duetothebuilding layout, itmayberequiredtostarterectionfromaspecifiedend. Insuchcases,itwillbenotedassuchontheerectiondrawings.
7.9.2. Sequencingofsteelshallbeclearlymarked ontheorderdocumentsatthetimeoforderentry.
7.10. CoordinationwithOtherTrades
7.10.1 SupportsfortheTrapezoidalSSRroofsystem shallbeprovidedandarerequiredasshowninthedrawingsandasnoted inthesespecifications. Allnecessaryclearancedimensionsforproperelevationsrelativetotheroofpanelshavebeenshown. Thecustomershallberesponsibleforcoordinatingthesedimensionalrequirementswithothertradesassociatedwiththebuildingroofsystem.
7.11. ErectionCare
7.11.1. Theerectormustbeskilledintheerectionofmetalbuildingsystemsandisresponsibleforcomplyingwithallapplicable local,federal,andstateconstructionandsafetyregulationsincluding OSHA regulations as well as any applicable requirements of local, national, orinternational
union
rules
or
practices.
The
Erector
remains
solely
responsible
for
the
safety and appropriateness of all techniques and methods utilized by its crews in theerectionofthemetalbuildingsystemand/ortheTrapezoidalSSRroofsystem. TheErectorisalsoresponsibleforsupplyinganysafetydevicessuchasscaffolds,runways,nets,etc.,whichmayberequiredbythegoverningcodestosafelyerectthemetalbuildingsystemand/orTrapezoidalSSRroofsystem.
7.11.2. Anchorage for safety devices may be added at an additional cost provided specificconnections are designed and clearly noted in Canam Steel Building Corporation orderdocuments. All anchorage points must be noted with exact location, magnitude, anddirectionofforceforafullybracedstructure.
7.11.3. TheerectoroftheTrapezoidalSSRroofsystem shallexercisegreatcareandattentionto
the
details
as
shown
on
the
erection
drawings
and
in
the
erection
manual
to
insure
asecureandproper fitofallcomponents. CanamSteelBuilding Corporationshallnotbe
responsible forsupervisingand/orcoordinating theerectionof theTrapezoidalSSR roofsystem with other trades. Erection drawings shall govern when a situation differs fromthatshownintheerectionmanual.
7.11.4. Dueconsiderationmustbegivenbytheerectortotheeffectsofthermalexpansionandcontraction when erecting a roof tiein to an existing structure to insure a safe, secure,weathertightcondition. Flashing fortieinstoexistingbuildings istypicallynot includedas part of the material provided by Canam Steel Building Corporation. Refer to thesectionsanddetailsforspecificmaterialsprovidedbyCSBC.
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
11/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page11
7.11.5. Theerectoracknowledgesthatalldetailsforallconditionscanbenotedontheplansandthat due care and judgment are required to make a safe and watertight condition.Sealantsandcaulksmayberequiredbaseduponactualconditionsencountered.
7.12. FieldCuttingofPanels
7.12.1. When fieldcutting or mitering Trapezoidal SSR roof panels, nonabrasive cutting toolssuch as nibblers or tinsnips shall be used. Abrasive cutting tools such as mechanicalgrinders,saws,shears,orscissorscandamagetheGalvalumeorpaintedfinishandcreateexcess metal shavings that can corrode the panels. The use of nonapproved cutting
devicesmay
void
your
manufacturers
warranty.
Section8. WallCovering
8.1. General
8.1.1. Wall covering shall be PBRpanel, Reverse Roll PBRPanel, or PBAPanel, precision rollformedfrom26gaugesteel.
8.1.2. ASTME283isanAirinfiltrationspecification.
8.1.3. ASTME331isaWaterpenetrationspecification.
8.1.4. All Canam Steel Building Corporation wall panels can meet ASTM E283 & E331
specificationswith
the
requirements
listed
below.
Wallpanelmaterialmustbe80KSIAddx3/32tapemastictoALLsidelapseams.Sidelapfastenerspacingis24O.C.MaximumMinimumpanelgauge:26 (24gaugemaybeavailableatadditionalcost)
8.2. PanelMaterial
8.2.1. Galvanized steel sheeting shall be processed in accordance with ASTM A653. Consultyour specific plant for minimum yield strength and grade of material. The galvanizedcoatingshallbe .90ozpersquarefoot(ClassG90) inaccordancewithASTMA653. ThespangleforgalvanizedpanelisbrightflatspangleinaccordancewithASTMA653.
8.2.2. Galvalumesteelsheetingshallbealuminumzincalloycoatedsteelsheet inaccordance
with
ASTM
A
792.
Consult
your
specific
plant
for
minimum
yield
strength
and
grade
of
material. Ithasacoatingthicknessof.55ozpersquarefoot.
8.2.3. WallpanelsprovidedbyCanamSteelBuildingCorporation forexterioruseareprecisionrollformed fromprepaintedG90galvanizedorGalvalumecoils. Coils to receive finishpaintsaresubjectedtoastrenuouscleaningprocesspriortocoating. Next,thecoilsareprimecoatedandovencured. The finishcoat isthenappliedandmonitored forproperovencure temperatureandcoloruniformity. Finishedmaterial issubjected tostringentquality control tests including: physical bend and impact resistance, film thickness,hardness, gloss, and color. This process is time tested and uses the industry provenSiliconized Modified Polyester paint system. A 70% Kynar 500 finish is available at anadditionalcostuponrequest.
8.3. PanelConfiguration
8.3.1.
CanamSteel
Building
Corporation
PBR
panel
provides
a36"
(915
mm)
net
coverage
and
consists of major ribs 1 1/4" (32 mm) high spaced at 12" (305 mm) on center with anextended purlin bearing sidelap to allow for additional sidelap support. Minor ribsreinforcetheflatareabetweenmajorribstominimizeoilcanning.
8.3.2. Canam Steel Building Corporation reverse roll PBRpanel in a recessed fastener panelwhichprovidesa36" (915mm) netcoverageand consistsofmajor ribs11/4" (32mm)deepspacedat12"(305mm)oncenterwithanextendedpurlinbearingsidelaptoallowfor additional sidelap support. Minor ribs reinforce the flat area between major ribs tominimizeoilcanning..
8.3.3. Canam Steel Building Corporation PBApanel is an architectural recessed fastener panel
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
12/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page12
whichprovidesa36"netcoverageandconsistsof11/4"(32mm)deepmajorribsspacedat12"(305mm)oncenterwithanextendedpurlinbearingsidelaptoallowforadditionalsidelapsupport. Ashallowvvalleyoccursbetweenthemajorribs.
8.4. TrimandFlashing
8.4.1. Colorcoated trim and flashing shall be supplied in 26 gauge. Trim shall be provided ateave, base, corners, framed openings, and where necessary to insure a properlyconstructedbuilding.
8.4.2.
All
exposed
trim
and
flashing
material
shall
be
manufactured
from
Galvalume,galvanized,orpaintedsteelstrip.
8.5. Fasteners
8.5.1. Paneltosecondary framing fasteners forallwallpanelsshallbea#12x11/4" (32mm)long selfdrilling carbon steel screw, hex head. Fastener shall have a painted head tomatchpaneland/ortrimcolor.
8.5.2. Paneltopanel,stitchfastenerforallwallpanelsshallbea#12x3/4"(19mm)longsharppointcarbonsteelscrew,hexhead. Fastenershallhaveapaintedhead to matchpaneland/ortrimcolor.
8.5.3. Fasteners required forsecuring trim tomasonryorconcretearenotsupplied byCanam
SteelBuilding
Corporation.
8.6. Sealants
8.6.1. Tubesealantsshallbeusedatalltrimendlaps,andshallbeapolyurethanesealant.
8.6.2. Sealants not provided by Canam Steel Building Corporation shall not be used withoutspecificapprovalfromCSBC.
8.7. Closures
8.7.1. Closures shall be manufactured of closedcell polyethylene foam to match the panelconfiguration.
8.7.2.
Closuresshall
be
supplied
as
required
to
provide
aclosed
wall
panel
profile
at
the
rake
condition.
8.8. InstallationofPanels
8.8.1. Allsidelapsshallbelappedaminimumofonefullrib. Panelendlapsshallbeaminimumof4"(101.6mm)longonwallpanels.
8.8.2. All wall panels shall be fabricated in one piece providing the length does not exceedpracticallimitsforshipmentorconstruction.
8.8.3. Storage and installation of the wall system shall be in accordance with Nucors printedinstructions.
8.8.4.
Standardmaximum
panel
length
shall
be
30 (9.14
m).
If
required,
lengths
of
up
to
45
(13.72)maybeprovided.
8.9. Cleanup
8.9.1. Alldirt,oil,grease,fingerprints,orothercontaminantsshallberemovedafterinstallationtoinsureproperservicelifeofthepaintsurface.
Section9. Accessories
9.1. WalkDoors
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
13/14
C a n a m
S t e e l
B u i l d i n g
C o r p o r a t i o n
S p e c i f i c a t i o n
G u i d e Page13
9.1.1. WalkDoorsprovidedbyCanamSteelBuildingCorporationarecommercialgrade,weldedconstruction. Door leafs are 1 3/4" (44.45 mm) thickness, 20 gauge galvanized facesheets, flush top and bottom channels with polystyrene insulated core. Hinge and lock
jambsarereinforcedwith10gaugeand14gaugematerialrespectively. Doorsarefactoryfinished baked enamel finish. 16 gauge galvanized subjambs are included for ease ofinstallation. WalkdoorsareprovidedKD(knockdown)forfieldassembly. Preassembledwalkdoorsareavailableatadditionalcost.
9.2. Windows
9.1.2.
Windows
provided
by
Canam
Steel
Building
Corporation
are
factoryassembled
and
are
selfflashing forapplicationwithallCSBCstandardwallpanelprofiles. Unlessotherwisespecified in the CSBC order documents, windows are insulated, clearglass. Galvanized
jambstiffenersaresuppliedforrigidityofinstallation.
9.3. FramedOpenings
9.3.1. Framing members for overhead doors shall typically be the same depth as the girts towhichtheyattach. Wallpaneledgeshallbetrimmedandflashedatallopenings.
9.3.2. Framing for overhead doors shall be primecoated or galvanized, as required per theCanamSteelBuildingCorporationorderdocuments.
9.4. LightTransmittingPanels
9.4.1. Translucent light panels shall be glass fiber reinforced composite panel of ACRYLIT,containing100%Acrylicresinmonomers.
9.4.2. Panelsshallbeproducedtomatchtheroof/wallpanelconfiguration.
9.4.3. Panelsshallweigheightouncespersquarefoot.
9.4.4. Nominallengthofpanelsshallbe50,10'0",or110.
9.4.5. Panelsshallhave5560%LightTransmission perASTMD1494.
9.4.6. PanelsshallhaveaBurnRate oflessthan21/2perminuteperASTMD635.
9.4.7.
Metalpanels
above
and
below
the
translucent
section
along
the
same
run
shall
not
be
shorter than the length of three purlin spaces. Roof translucent panels shall not belocatedattheeaveorridge. LightTransmittingpanelsshallbeplacedsuchthattherearefourmetalpanelsminimumbetweeneachLTP.
9.4.8. The buyer shall advise all parties and the owner that Light Transmitting Panels notdesignednorintendedforfoottraffic.
9.4.9. PBRpanel Light Transmitting Panels have a UL and Florida approval rating at 50maximumpurlinspace.
9.5. RakeandEaveExtensions/Canopies
9.5.1.
Rake
and
eave
extensions
shall
be
comprised
of
cantilevered
extension
beams
or
roofpurlins,10(0.3m)to60(1.83m)beyondsteelline,completewithallnecessarytrim,
closures,andflashingtoprovideaweathertightroofcontinuationoftheroofline. Otherdimensionsmaybeavailable.
9.5.2. Canopiesshallconsistofroofpanelssupportedbycantileveredcanopybeamsandpurlinsfor20(0.61m)to150(4.57m)projection,completewithallnecessarytrim,closures,andflashingtoprovideaweathertightextension.
9.6. LinerPanel
9.6.1. Liner panel for a walls or roof is produced from 29 or 28 gauge material with a white
-
8/10/2019 CSBC_Specification Guide_2010.10.pdf
14/14
straight polyester finish or unpainted galvalume plus as called for in the Canam SteelBuildingCorporationorderdocuments. Linerpanel isnot intendedtobeexposedtotheeffectsofweather,sunlight,moisture,orcorrosiveenvironments.
Section10. StandardServiceabilityCriteria
Themostcommonlyaddressedcriteria inpreengineered steelbuildingsystemsaredeflectionsandthermalexpansion/contraction. Mostbuildingcodesaresilentonserviceabilityrequirements,leavingthem up to the project Engineer of Record or project architect. However, in most cases with preengineered buildings, deflection limits are based upon rules of thumb or past experience by the
building
manufacturer.
Canam
Steel
Building
Corporation
standards
are
based
upon
the
AmericanInstitute of Steel Construction design guide, Serviceability Design Considerations for LowRise
Buildings. Anybuildingorderwillmeetorexceed the followingcriteriaunlessspecificallyspecifiedotherwiseintheorderdocuments.
STRUCTURALELEMENTS LIMIT LOADING
WALLGIRTSSUPPORTING:MetalWallPanelsMasonryorConcreteWallsDryvit,Wood,Sheetrock,Etc.
Bay/90HorizontalBay/240HorizontalAsspecifiedbyBuyer
10YearWind10YearWind10YearWind
PURLINS:RoofSlopesgreaterthan1/4:12 Bay/150Vertical Collateral+Live/SnowLoad
WALLPANELS:Metal,byCSBCMaterialbyOthers
NospecialconsiderationNotbyCSBC
ROOFPANELS:RoofSlopesgreaterthan1/4:12 PurlinSpacing/180Vertical
PurlinSpacing/180VerticalCollateral+Live/SnowLoad200lb.LoadonOnePanel
FRAMESSUPPORTING:RoofSlopesgreaterthan 1/4:12MetalWallPanelsTiltup,PrecastorMasonryWalls
RafterSpan/150VerticalEaveHeight/60HorizontalWallHeight/100Horizontal
Collateral+Live/SnowLoad10YearWind10YearWind
Section11. Execution
11.1. Erection RECTION of the building system shall be in accordance with the appropriateerectiondrawings,erectionguidesand/orotherdocumentsfurnishedwiththematerials. Itshall be the responsibility of the erector to comply with all appropriate legal and safetyrequirements. The erector shall determining and provide any and all temporary bracing,shoring,blocking,bridging,and/orsecuringofcomponents,Etc.,asrequiredduringerectionofthebuilding.