CRYSTAL SERIES REI-B330NP, DP REI-B380NP, DP - Rinnai · 2020-03-02 · 10. Electronic Control 11....
Transcript of CRYSTAL SERIES REI-B330NP, DP REI-B380NP, DP - Rinnai · 2020-03-02 · 10. Electronic Control 11....
(For SG and MY Models)
CRYSTAL SERIESREI-B330NP, DP REI-B380NP, DP
Sliding Rail Set Installation Guide 11
16
17 - 18
19
20
21
22 - 23
14 - 15
Parts Content Checklist
infirm,
1 x Handshowerc/w filter mesh washer
2 x Wall Plug & Screw Set
1 x Sliding Rail Set
Parts Content Checklist (For Unit C/W Normal Shower Accessories)
1 x Handshowerc/w filter mesh washer
1 x 2-Tier RS Top
1 x 2-Tier RS Bottom
1 x 2-Tier Diverter Valve
Parts Content Checklist (For Unit C/W Rain Shower Accessories)
8
10
12
6
7
9
12. Rotatable Soap Dish(for Pump model only)
2-Tier Diverter Valve
Non Pump model
1
3
4
4 4
4
11
8
12
14
2
5
6
7
9
15
3
7
18
11
12
14
9
13
16
15
8
10
17
10
157
2
6
DC Pump model
1. Heating Element2. Mouting Holes (4 Nos)3. Terminal Block4. Cable Entry5. Termostat Entry6. RCD Assembly (for RCD model only)7. Heater Base8. Indicator Light9. Water Tank
10. Electronic Control11. Triac12. Flow Switch Assembly13. RCD TEST RESET14. Water Inlet15. Water Outlet16. Pump Speed Control17. DC Pump Control Board18. DC Pump Assembly
Secure Rainshower(RS) 2-Tier Diverter to Rainshower(RS) Sliding Rail.
Rainshower(RS) 2-Tier Diverter to Rainshower(RS)
Rainshower(RS) 2-Tier Diverter.
to 2-Tier Diverter outlet (BOTTOM: to Handshower)
outlet of Rainshower(RS) 2-Tier Diverter.
2-TIER DIVERTER VALVE
TOHANDSHOWER
TO H
AND
SHO
WER
Drill holes and insert wall plugs provided according the recommended dimension as shown (2 holes)
11Sliding Rail Set Installation Guide
�tting wall plug to both holes.
plug
screws.
respectively. arrow shown in the �gure.
able to withstand 250N vertical
12
3.8 15.9
ServiceStop Valve
13
Mount to wall
Screw x 4
14
FILTERCLOSE
OPEN
PLUMBING CONNECTIONSCOMPLETE THIS PROCESS BEFORE WIRINGCONNECTIONCONNECTION PROCEDURE: Connect the water supply to the inlet of the shower via 15mm copper, stainless steel or plastic pipe using a 15mm x 15mm elbow compression fitting.Do not use excessive force when making these connections.
FITTING THE STOP VALVEFit the Stop valve (Warning: Conductive Valve shall not be used) by secure to the unit Inlet.Note:It is compulsory to have the product installed with stop valve (with filter) provided, failing which, dirt particles may cause failure of flow switch assembly.
Ensure the supplied washers are in place before connecting inlet and the Stop Valve. Fit the other point of Stop Valve to the incoming water supply.Ensure that the backplate of the unit is flat on the wall and positioned squarely. Tighten the fixing screws. Turn on the water supply and check for leaks in the pipework connection to the shower.NOTE: At this stage no electricity can flow through the unit.ELECTRICAL CONNECTIONWARNING: THIS UNIT MUST BE EARTHED.
SWITCH OFF THE ELECTRICITY SUPPLY. The cable entry points are shown in the figure below. Determine the cable entry to the unit.a) Side entry – Poke the electrical cable through the Rubber grommet.Route the cable into the shower unit and connect to the terminal block (Fig. 1) as follows:-Earth cable to terminal marked ‘ ’Neutral cable to terminal marked ‘ N ’Live cable to terminal marked ‘ L ’
IMPORTANT: Fully tighten the terminal block screws and ensure that no cable insulation is trapped under the screws. Loose connections can result in cabling overheating. DO NOT switch on the electricity supply until the cover has been fitted.
15
aWire Entry
Filter Mesh Washer
filter mesh at the handshower.
16
The ‘RCD’ light will light meaning the unit is on standby (for RCD model only).
Turn the knob clockwise to LOW sign, the‘HEATER’ light will light up.
Turn the knob anti-clockwise to OFF sign;the ‘HEATER’ light will switch OFF again.
Continual turn of the knob clockwise, thetemperature of the water should riseslightly.Allow a few seconds for the warm waterto reach the handshower, this shows thatthe power setting is operating correctly.
Set the shower temperature by rotatingthe Knob as necessary. Turn the knobclockwise for hotter water and anticlock-wise to LOW sign position for cooler water.
17
ON
Pump Speed Control Knob
‘HEATER’ ‘RCD’
18
LOW
HIGH
19
20User Maintenance
running water. Ensure al dirt particles are
21
Specification of Non-Pump Model
Available in 3.3 & 3.8kW, 230-240V AC, 50Hz
418mm x 221mm x 98mm
22
380 kPa (55 psi)
2.80 kgs1.50 kgs4.30 kgs1.50 kgs
SWT-EC
SCHEMATIC WIRING DIAGRAM (NON-PUMP MODEL C/W RCD)
RY2COM NO
COM NORY1
Nin
E2CNout
Lin Lout
WIR
ING
TE
RM
INA
L
N
Mai
ns S
uppl
y
To Heater Chasis
TEST RESET
RCDTEST/RESET
Thermal Cut-out
ELECTRONIC CONTROL BOARD
ON/OFFSWITCH
POWERCONTROL
SWT-EC
VR
LN
2
13
G
T2
T1
TRIAC
INDICATORBOARD
HEATING ELEMENT
FLOWSWITCH
4
SCHEMATIC WIRING DIAGRAM (NON-PUMP MODEL W/O RCD)
Rev B 01.03.2020
3.10 kgs1.70 kgs4.60 kgs1.70 kgs
Specification of DC Pump Model
Available in 3.3 & 3.8kW, 230-240V AC, 50Hz
418mm x 221mm x 98mm
23
380 kPa (55 psi)
SCHEMATIC WIRING DIAGRAM (DC PUMP MODEL W/O RCD)
WIR
ING
TER
MIN
AL
N
Mai
ns S
uppl
y
To Heater Chasis
Thermal Cut-out
PUMP SPEED CONTROL
ELECTRONIC CONTROL BOARD
ON/OFFSWITCH
POWERCONTROL
SWT-EC
VR
VR 0-100K
POTL
LN
N EC2
13
G
T2
T1
TRIAC
RD/SWPUMP
3
M
LVDC/LVDC 2
INDICTORBOARD
HEATING ELEMENT
6
SCHEMATIC WIRING DIAGRAM (DP PUMP MODEL C/W RCD)
RY2COM NO
COM NORY1
Nin
E2CNout
Lin Lout
WIR
ING
TE
RM
INA
L
N
Mai
ns S
uppl
y
To Heater Chasis
TEST RESET
RCDTEST/RESET
Thermal Cut-out
PUMP SPEED CONTROL
ELECTRONIC CONTROL BOARD
ON/OFFSWITCH
POWERCONTROL
SWT-EC
VR
VR 0-100K
POTL
LN
N EC2
13
G
T2
T1
TRIAC
RD/SWPUMP
3
M
LVDC/ LVDC2
INDICATORBOARD
HEATING ELEMENT
4