CRITERES DE SERTISSAGE

1
CRITERES DE SERTISSAGE Definitions INSULATION CRIMP WITHOUT SEAL INSULATION CRIMP WTH SEAL Insulation crimp Type A (F-crimp) Legend : 1- Crimp width 2- Crimp Height 3- Wrap angle Insulation crimp Type B (wrap crimp) Legend : 1- Contact area 6- Insulation crimp 2- Connection A 7- Rear runout 3- Front runout 8- Separation bridge 4- Conductor crimp 9- Connection B 5- Crimp connection Insulation crimp type C (overlap crimp) 1- Contact element 2- Conductor end 3- Conductor 4- Insulation Symmetrical O-shaped single-conductor crimp - O-crimp) Asymmetrical O-shaped single-conductor crimp (wrap crimp) Unacceptable General appearance Insulation crimping Wire crimping Strands too twisted Insulation scraps on stripped wire Strands not twisted Damaged insulation Insulation badly cut Strands damaged by stripping tool Strands crushed by insulation barrel Wire stripping too short Loose strands Wire stripping too long Insulation crimped by wire barrel Check and evaluations Acceptable Wire section too small Insulation pierced by insulation barrel Insulation pierced by insulation barrel Insulation barrel not correctly closed Wire section too big Insulation barrel not correctly shaped ans closed Insulation barrel too tight Insulation barrel not coorectly closed Measuring the Crimp height (micrometer) Retention test = depend of the contact Crimping not symmetrical Excess of material extrusion Wrong or damaged anvil Crushing not correct, shapeless wire barrel's bottom Wire section too big Unadequate compacting Wire section too small Distance between crimp face ends Formation of cracks in the crimp base Big burr unacceptable Control 1 to 7 must be done in case of doubt in visual control inspection of the crimping quality + all 300 000 cycles + change of elements of crimping + new applicator. 1 H Crimp height 2 W Crimp width 3 Fc Face end clearance 4 CFE Distance between crimp face ends 5 Bh burr height 6 Bw burr width 7 Sb Base thickness S is the thickness of material of the contact before the crimping 1,73 Measuring the Crimp width (cross section) H/W ratio et compaction of crimping compaction crimping The ration H/W is acceptable when the result is between 55% (min) and 70% (max) --> This criterion is conform in case when H and W defined in the control sheet are respected. Fc 0,5 x S 3 CFE 0,5 x S 4 Sb 0,75 x S 7 For the crimping is conform: - - Bh S - Bw 0.5 X S - None cracking is accepted 5 5 6 cracking 6 Stripping length precisely set and cut The wire stripped section must be undamaged The wire stripped section must be clean and free of insulation scraps Gripping marks on insulation are allowed Insulation wire Both wire and insulation must be clearly visible Insulation barrel correctly closed Insulation barrel correctly shaped and closed Insulation barrel correctly aligned and closed The crimping is symmetrical. The strands are uniformly compacted, there are no empty spots. There's no material extrusion and/or terminal deformation. The flat spots are clearly visible and aligned Flat spot Flat spot The flat spots are an important mark of the anvil on the terminal bottom, they help with the strands compacting and keep the terminal aligned with the anvil itself 1 2 -H -W 1 2 W Date d'application : 15/02/11 V3008/8.2.4/A285 rev2

Transcript of CRITERES DE SERTISSAGE

Page 1: CRITERES DE SERTISSAGE

CRITERES DE SERTISSAGE

Definitions INSULATION CRIMP WITHOUT SEAL INSULATION CRIMP WTH SEAL

Insulation crimp Type A (F-crimp)

Legend : 1- Crimp width 2- Crimp Height 3- Wrap angle

Insulation crimp Type B (wrap crimp)

Legend : 1- Contact area 6- Insulation crimp2- Connection A 7- Rear runout3- Front runout 8- Separation bridge4- Conductor crimp 9- Connection B5- Crimp connection Insulation crimp type C (overlap crimp)

1- Contact element2- Conductor end3- Conductor4- Insulation

Symmetrical O-shaped single-conductor crimp -O-crimp)

Asymmetrical O-shaped single-conductor crimp (wrap crimp)

Unacceptable

Gen

eral

app

eara

nce

Insu

latio

n cr

impi

ngW

ire c

rimpi

ng

Strands too twisted Insulation scraps on stripped wire

Strands not twisted

Damaged insulation Insulation badly cut Strands damaged by stripping tool

Strands crushed by insulation barrel

Wire stripping too short Loose strands

Wire stripping too long Insulation crimped by wire barrel

Check and evaluationsAcceptable

Wire section too small

Insulation pierced by insulation barrel

Insulation pierced by insulation barrel

Insulation barrel not correctly closed Wire section too big Insulation barrel not

correctly shaped ans closed

Insulation barrel too tight

Insulation barrel not coorectly closed

Measuring the Crimp height (micrometer)

Retention test = depend of the contact

Crimping not symmetrical

Excess of material extrusion

Wrong or damaged anvil

Crushing not correct, shapeless

wire barrel's bottom

Wire section too big

Unadequate compacting

Wire section too small

Distance between crimp face ends

Formation of cracks in the crimp base

Big burr unacceptable

Control 1 to 7 must be done in case of doubt in visual control inspection of the crimping quality + all 300 000 cycles + change of

elements of crimping + new applicator.

1 H Crimp height 2 W Crimp width 3 Fc Face end clearance4 CFE Distance between crimp face ends5 Bh burr height6 Bw burr width7 Sb Base thickness

S is the thickness of material of the contact before the crimping

1,73

Measuring the Crimp width (cross section)

H/W ratio et compaction of crimping

compaction crimpingThe ration H/W is acceptable when the result is between 55% (min) and 70% (max)--> This criterion is conform in case when H and W defined in the control sheet are respected.

Fc ≥0,5 x S3 CFE ≤ 0,5 x S4

Sb ≥ 0,75 x S7

For the crimping is conform:

- - Bh ≤ S

- Bw ≤ 0.5 X S

- None cracking is accepted

5

5

6cracking

6

Stripping length precisely set and cutThe wire stripped section must be undamaged The wire stripped section must be clean and free of insulation scrapsGripping marks on insulation are allowed

Insulation wire

Both wire and insulation must be clearly visible

Insulation barrel correctly closed

Insulation barrel correctly shaped and closed

Insulation barrel correctly aligned and closed

The crimping is symmetrical. The strands are uniformly compacted, there are no empty spots.

There's no material extrusion and/or terminal deformation. The flat spots are clearly visible and aligned

Flat spot Flat spot

The flat spots are an important mark of the anvil on the terminal bottom, they help with the strands compacting and keep the terminal aligned with the anvil itself

1

2

-H

-W

1

2

W

Date d'application : 15/02/11 V3008/8.2.4/A285 rev2