Cree Racine Engineering Services Testing Laboratory (RESTL ... · 410 0.001777 580 0.185053 750...
Transcript of Cree Racine Engineering Services Testing Laboratory (RESTL ... · 410 0.001777 580 0.185053 750...
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
This report contains data that are not covered by the NVLAP accreditation.
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 1 of 13
Report Number: PL08034-001A
Model: OSQ-A-xx-5ME-B-40K-ULxxxxx
Date: 06/06/2016
Cree Racine Engineering Services Testing Laboratory
(RESTL) Photometric Testing and Evaluation
Report
Prepared For:
Christopher Strom
Cree, Inc.
9201 Washington Avenue
Racine, WI 53406
Prepared By: Approved By:
Linjie Li, LC, Test Engineer Christopher McLaurin, Photometric Specialist
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 2 of 13
Product Information
Manufacturer Cree, Inc.
Model Number (SKU) OSQ-A-xx-5ME-B-40K-ULxxxxx
Serial Number PL08534-001
LED Type XHP70
Product Description
Black finned metal housing. Two circuit boards each with four LEDs. Two optic carriers each with one black plastic uplight shield. One clear plastic optical lens below each LED.
Driver Information (Where Applicable)
Philips XI150C105V140CNF1
Length Width Height
20.0” 19.0” 4.0”
Sample
The following sample was submitted for evaluation
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 3 of 13
Key Photometric Data Sphere Output Goniophotometer
Luminous Flux 10708.6 10518.8 lm
Efficacy 123.68 121.42 lm/W
Correlated Color Temperature (CCT) 3787 K
Color Rendering Index (CRI) 74
R9 -13
Duv 0.00180658
S/P Ratio* 1.46
Sphere Goniophotometer
Electrical Measurements 120V 277V 120V 277V
Input Wattage 86.58 86.46 86.63 86.53 W
Input Current 0.73 0.33 0.72 0.33 A
Input Voltage 120.09 276.94 120.08 276.99 V
Power Factor 0.995 0.938 0.996 0.940
Off-State Power 0 0 0 0 W
Total Harmonic Distortion (Voltage) 0.06 0.06 0.06 0.08 %
Total Harmonic Distortion (Amperage) 6.56 15.35 6.52 15.30 %
Note: All photometric measurements taken at 120VAC.
Luminous Intensity Distribution Goniophotometer
Max Candela 4489.5 Cd
Angle of Max Candela (Horizontal) 45 ˚
Angle of Max Candela (Vertical) 70 ˚
Key Test Parameters Sphere Output Goniophotometer
Stabilization Time 57 68 min
Total Operating Time (Stabilization + Test) 62 88 min
Ambient Temperature 25.5 24.7 ˚C
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 4 of 13
Chromaticity Coordinates
x y u v u’ v’ Duv
0.3918 0.3875 0.2283 0.3386 0.2283 0.5079 0.00180658
Color Rendering Index Details
Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14
74 73 79 85 75 72 71 83 58 -13 51 72 45 73 91
Chromaticity Diagram
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 5 of 13
Spectral Distribution
λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm
360 0.000328 530 0.139612 700 0.024771
370 0.000234 540 0.150778 710 0.018543
380 0.000201 550 0.158956 720 0.013742
390 0.000160 560 0.168369 730 0.010077
400 0.000054 570 0.177607 740 0.007370
410 0.001777 580 0.185053 750 0.005577
420 0.013585 590 0.187808 760 0.004083
430 0.055727 600 0.183505 770 0.003056
440 0.135865 610 0.172865 780 0.002264
450 0.184870 620 0.155543 790 0.001674
460 0.070291 630 0.135147 800 0.001194
470 0.034599 640 0.113646 810 0.000851
480 0.022787 650 0.092714 820 0.000587
490 0.026780 660 0.073993 830 0.000426
500 0.050989 670 0.057429
510 0.086501 680 0.043789
520 0.118516 690 0.033083
Dominant Wavelength 579 nm
Peak Wavelength 448 nm
Spectral Power Distribution (W/nm)
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 6 of 13
Zonal Lumen Summary
Zone Lumens % of Total Zone Lumens % of Total
0-5 26.0 0.2% 90-95 0 0%
5-10 75.2 0.7% 95-100 0 0%
10-15 119.4 1.1% 100-105 0 0%
15-20 162.0 1.5% 105-110 0 0%
20-25 203.2 1.9% 110-115 0 0%
25-30 249.3 2.4% 115-120 0 0%
30-35 326.7 3.1% 120-125 0 0%
35-40 403.9 3.8% 125-130 0 0%
40-45 446.0 4.2% 130-135 0 0%
45-50 537.6 5.1% 135-140 0 0%
50-55 686.2 6.5% 140-145 0 0%
55-60 860.7 8.2% 145-150 0 0%
60-65 1,079.7 10.3% 150-155 0 0%
65-70 1,394.0 13.3% 155-160 0 0%
70-75 1,644.4 15.6% 160-165 0 0%
75-80 1,382.6 13.1% 165-170 0 0%
80-85 767.1 7.3% 170-175 0 0%
85-90 155.0 1.5% 175-180 0 0%
Total 10518.8 lm 100%
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 7 of 13
Candela Plot Illuminance Plot
Roadway Utilization Roadway Summary Lumens % Lamp
Distribution Type VS
Downward Street Side 5,258.4 50%
Downward House Side 5,258.4 50%
Downward Total 10,516.8 100%
Upward Street Side 0 0%
Upward House Side 0 0%
Upward Total 0 0%
Total Lumens 10,516.8 100%
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 8 of 13
Luminaire Classification System
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 9 of 13
Candela Tabulations
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
0 1095 1095 1095 1095 1095 1095 1095 1095 1095 1095 1095 1095 1095 1095 1095 1095 1095 1095 1095
2.5 1087 1086 1087 1088 1088 1089 1090 1091 1091 1091 1091 1093 1093 1094 1094 1095 1094 1093 1093
5 1075 1073 1075 1075 1077 1078 1080 1082 1082 1082 1082 1083 1083 1083 1082 1082 1081 1079 1080
7.5 1046 1045 1046 1048 1051 1053 1056 1059 1060 1060 1060 1061 1060 1058 1057 1056 1054 1052 1052
10 1015 1014 1016 1018 1022 1024 1028 1032 1034 1035 1035 1035 1032 1029 1028 1026 1024 1022 1021
12.5 992 992 995 998 1001 1004 1007 1012 1016 1016 1016 1015 1012 1010 1007 1006 1003 1000 998
15 978 978 981 984 988 990 994 1000 1006 1007 1004 1001 997 995 993 991 988 985 982
17.5 967 967 971 973 977 979 984 992 1000 1003 999 993 986 984 983 980 978 974 972
20 956 956 959 962 966 970 977 987 996 1000 996 989 980 975 973 971 967 964 962
22.5 943 943 947 952 959 967 973 982 993 997 992 983 975 968 963 959 955 951 949
25 938 940 944 950 959 970 979 985 994 999 993 982 975 970 960 953 949 945 942
27.5 944 948 957 963 976 986 991 1002 1012 1016 1008 998 993 984 974 966 958 949 946
30 957 965 988 1000 1013 1024 1022 1033 1048 1051 1041 1032 1027 1028 1019 1009 999 973 963
32.5 998 1037 1092 1113 1119 1130 1119 1109 1116 1120 1109 1110 1128 1139 1128 1128 1112 1056 1013
35 1073 1126 1201 1227 1233 1246 1245 1216 1210 1217 1199 1214 1251 1252 1235 1236 1212 1134 1074
37.5 1080 1122 1208 1242 1246 1254 1251 1239 1263 1288 1248 1225 1248 1249 1238 1237 1210 1125 1085
40 1072 1087 1149 1180 1191 1199 1201 1228 1311 1362 1290 1223 1205 1200 1185 1168 1140 1083 1078
42.5 1068 1062 1099 1129 1153 1170 1190 1260 1396 1487 1370 1253 1200 1180 1160 1133 1104 1064 1067
45 1076 1062 1097 1138 1175 1198 1232 1333 1526 1665 1495 1318 1239 1208 1182 1142 1100 1059 1067
47.5 1118 1110 1151 1195 1236 1261 1302 1433 1693 1878 1665 1420 1316 1272 1246 1201 1153 1109 1124
50 1222 1209 1247 1294 1334 1359 1402 1557 1874 2091 1855 1553 1426 1374 1348 1306 1254 1204 1219
52.5 1346 1317 1354 1406 1453 1486 1537 1707 2064 2295 2051 1710 1567 1503 1469 1418 1357 1310 1316
55 1431 1404 1444 1505 1570 1630 1710 1907 2297 2526 2282 1901 1733 1643 1579 1514 1446 1391 1413
57.5 1457 1459 1520 1596 1685 1773 1881 2119 2563 2785 2535 2102 1901 1771 1676 1587 1500 1444 1439
60 1514 1506 1569 1685 1802 1913 2076 2428 2962 3175 2921 2385 2069 1888 1768 1653 1545 1484 1480
62.5 1588 1585 1655 1777 1919 2100 2356 2789 3352 3534 3295 2730 2322 2045 1860 1725 1611 1546 1536
65 1729 1731 1813 1955 2147 2370 2643 3107 3692 3865 3627 3040 2588 2279 2061 1876 1739 1666 1651
67.5 2000 2007 2107 2280 2482 2695 2963 3454 4034 4202 3959 3377 2891 2573 2340 2147 1978 1900 1882
70 2475 2450 2528 2659 2817 3002 3254 3763 4318 4489 4255 3712 3209 2888 2670 2495 2336 2261 2246
72.5 2683 2632 2688 2802 2942 3108 3346 3825 4333 4488 4281 3812 3338 3039 2867 2735 2627 2611 2599
75 2561 2517 2547 2654 2773 2911 3134 3568 4022 4150 3974 3571 3157 2885 2743 2619 2516 2499 2503
77.5 2172 2132 2163 2296 2438 2574 2761 3110 3479 3571 3407 3078 2752 2516 2377 2229 2106 2084 2098
80 1586 1611 1703 1789 1918 2079 2259 2541 2827 2909 2770 2503 2218 1957 1746 1579 1482 1491 1530
82.5 975 998 1271 1322 1380 1462 1580 1802 2047 2123 1959 1665 1402 1212 1095 1014 986 949 929
85 521 529 861 926 952 979 1007 1038 1029 974 864 795 756 728 711 683 680 413 336
87.5 79 75 129 169 194 199 204 240 282 268 175 219 186 155 139 118 108 81 82
90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 10 of 13
Candela Tabulations (Continued)
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 11 of 13
Integrating Sphere Equipment List
Description Manufacturer Model Serial Number
2M Sphere Everfine 2M 1004156T
CCD Array Spectrometer Otsuka MC-9801 98010360
Programmable AC Source Adaptive FC200 2280220
Power Analyzer Yokogawa WT310 C2QC04045V
Goniophotometer Equipment List
Description Manufacturer Model Serial Number
AC Power Source Chroma 61602 616020002300
Type C Goniophotometer LSI / UL 6440T 6440PN2028
Spectroradiometer Gooch & Housego 770VIS/NIR 12415212
Power Meter Yokogawa WT210 91M945458
Test Methods Used:
Title Description
ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment
CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources
CIE Pub. 15:2004 Colorimetry
IES LM-58:1994 Spectroradiometric Measurements
IES LM-65:2001 Single-Ended Compact Fluorescent Lamps – Life Test Performance
IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products
Reference Standard Used:
Equipment Description
2m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number F119
Type C Goniophotometer and Spectrometer
Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Numbers 13C069. 13C070, 13C071. For color calibration of spectrometer, 13C074.
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 12 of 13
Disclaimers:
This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.
The results contained in this report pertain only to the tested sample.
This report shall not be reproduced, except in full, without written approval of the RESTL.
*Items marked with a single asterisk are not covered by the NVLAP accreditation.
In the event that the recorded temperature is outside of 25 ± 1˚C, this is considered a non-standard condition.
** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as
“Sphere” or “Integrating Sphere”, were performed by the subcontracted laboratory identified in the footer on the
first page of this report. Subcontracted testing is strictly integrating sphere based. All other tests are
performed using a Type C goniophotometer.
The integrating sphere information in the equipment list, report items marked with **, or results specifically
identified as “Sphere” or “Integrating Sphere”, are the actual equipment used, and test results produced, by the
subcontracted laboratory when subcontracting is indicated on the cover page.
Additional Comments:
The photos below are intended to show the orientation and fixturing/set-up of the units under test. These
are critical to understanding the results of the test given the sensitivity of many products and
measurement systems to orientation and set-up considerations, and also for reproducing the conditions of
the test.
Goniophotometer Integrating Sphere
NVLAP Lab Code 500089-0
Test Report Number: PL08534-001A RESTL-R010 Rev F
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 13 of 13
Document Revision History:
Each subsequent revision of this report replaces the preceding report.
Date Rev DCN # Change at the time of this test By Approval
06/06/16 A DMS Origination L .Li C. McLaurin