Creating life long relationships.
Transcript of Creating life long relationships.
Creating life long relationships. Our Network Components keep your cable systems intact.
2 www.prysmiancable.com.au | www.prysmiancable.co.nz
Medium Voltage Accessories to link electrical infrastructuresAccessories play a vital role in a power system. Prysmian has gained expertise in the design, manufacture and testing of products across all voltages during many years of partnership with customers.
We can offer you a comprehensive range of accessories for glanding, jointing, connecting and terminating MV systems. The range includes joints (also transition, trifurcating and branch joints), terminations (both for indoor and outdoor use) and separable connectors.
In addition we can provide you with engineering services capable of fulfilling any power system specifications or requirements and of delivering customised solutions.
Our Network Components keep your cable systems intact.To link the cable systems and provide communities with a continuous flow of power, you not only need reliable cables, you need dependable components to keep it all together, too. Built on decades of experience we develop state-of-the-art joints, terminations and connectors that’ll give your MV network long-lived stability – and you peace of mind.
All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group: any modification or alteration afterwards of product may give different result. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian Group reserves the right to amend this specification without prior notice. This specification is not contractually valid unless specifically authorised by Prysmian Group.
Table of ContentsMedium Voltage Accessories to link electrical infrastructures 2
Network Components Locations 4
Evolution of the Technology & Design 5
CABLE JOINTS 7
ECOSPEED™ – COLD SHRINK JOINT 8
TERMINATIONS 11
TERMFIT™ – COLD SHRINK TERMINATION 12
CONNECTORS 15
STRAIGHT CONNECTOR – MSCS/EC-250-A 16
STRAIGHT CONNECTOR – MSCS/EC-400-B 18
STRAIGHT CONNECTOR – FMCS-400 20
ELBOW CONNECTOR – MSCE/EC-250-A 22
ELBOW CONNECTOR – FMCE-400 24
TEE CONNECTOR – MSCT/EC-630-C 26
ACCESSORIES FOR SERIES 400 28
INTERFACES 30
3www.prysmiancable.com.au | www.prysmiancable.co.nz
Prysmian Group is world leader in the energy and telecom cable systems industry. With almost 140 years of experience, sales exceeding €11 billion (pro-forma as of 31.12.2017), about 30,000 employees in over 50 countries and 112 plants, the Group is strongly positioned in high-tech markets and offers the widest possible range of products, services, technologies and know-how.
The Prysmian Group corporate brand operates in the market through three distinct commercial brands – Prysmian, Draka and General Cable. These are three of the global cable industry’s strongest brands, characterised by highly complementary products and services. We use our three commercial brands when talking about products and solutions, and each represents a specific part of the overall offering that Prysmian Group presents to its customers.
4 www.prysmiancable.com.au | www.prysmiancable.co.nz
SUZHOU / YIXING
Network Components LocationsSeven plants in Europe and two state-of-art plants in China.
MILAN – ITALY Headquarter and R&D Laboratories
QUATTORDIO – ITALY MV solutions & Compounds
LIVORNO – ITALY EPR, Click-Fit & Speed range
WREXHAM – UK Components
BISHOPSTOKE – UK HV & Subsea
SENS – FRANCE MV joints and terminations
CORNIMONT – FRANCE MV terminations
DELFT – THE NETHERLANDS HV Click-fit
SUZHOU – CHINA HV solutions
YIXING – CHINA MV solution
MV JointsProduction of the Compound and of the main body in Quattordio (IT).
Expansion, kitting & distribution in the APAC region in Yixing (CN).
MV TerminationsEngineering in Milan and France.
Production and Kitting in Yixing (CN).
QUATTORDIO
MILAN
DELFT
CORNIMONT
SENS
BISHOPSTOKE
WREXHAM
LIVORNO
5www.prysmiancable.com.au | www.prysmiancable.co.nz
Cold Shrink Technology Heat Shrink Technology
All components rebuilding the cable layers are assembled in the factory on the same carrier.
Different sleeves and tapes rebuilding the cable layers are supplied in a kit.
It is 100 % electrically tested in the factory like cables. These individual components cannot be pre-tested in factory.
Reduced parking length, it can be used in congested and tight trenches.
Long parking length needed in the trench to pre-position the different components on the cable.
Compact design embedded on a single carrier which can reduce installation errors and external contamination.
Requires multiple sleeves which can increase the risk of external contamination during installation.
Torch and hot work permit not required. No Fire Hazard. Overall safe installation process
Requires torch and hot work permit which can lead to fire hazard and HSE Risk
Ease & Reliability of installation. Integrity of the Joint installation will be uniform thanks to the elastic properties of material used.
Integrity of the Joint installation highly dependant on the Skill level of Jointer
Elastic material creates a dynamic seal, exerts a permanent pressure on the cable which ensures the accessory performances during service.
Non elastic layers can create static interfaces with the cable layers. Successive mechanical stresses (thermomechanical forces, manhole maintenance…) can lead to Leakage and watertightness issues; Voids development.
Evolution of the Technology & Design
• 1945
ACCESSORIES FOR PILC CABLE
Pre-impregnated paper tapes encapsulated in lead sleeves plumbed on site.
• 1975
HEAT SHRINK TECHNOLOGY
Use of prefabricated components based on thermoplastic polyole-fin materials heated up again on the field.
• Beg. 1980s
PREMOULDED ACCESSORIES
Use of pre-fabricated components based on EPR rubber.
• Beg. 1970s
TAPE INJECTED/CASTED ACCESSORIES
• Self-amalgamating tapes started to replace pre-impregnated paper tapes.
• Cast cold-curing resins rebuilt part of the insulation and the outer protection of the joint.
• 1994
COLD SHRINK TECHNOLOGY
• Use of prefabricated components, extrudes or moulded Ethylene Propylene Diene Monomer rubber (EPDM) or silicone rubber (SIR) components with elastic properties.
• They are radially expanded on a carrier.
Up to 60 % installation time savings can be achieved using Cold Shrink in comparison with other technologies.
Save up to
60 % installation
time.
7www.prysmiancable.com.au | www.prysmiancable.co.nz
CABLE JOINTS
ECOSPEED™ – COLD SHRINK JOINT
8 www.prysmiancable.com.au | www.prysmiancable.co.nz
Description
ECOSPEED™ cold shrink joint for Um up to 36 kV polymeric cables. For armoured cable, please contact us for further information.
Utilisation
• Jointing polymeric insulated cables of different specifications.
• Conductor sizes equal or unequal.
• May be directly buried.
• Jointing cables laid underground, in tunnels on horizontal, racks, or aerial.
• Transition joint between extruded and paper insulated cables.
Cables
• Single core polymeric insulation.
• Insulation voltage up to 36 kV (Um).
• Copper or aluminum conductor.
• Conductor sizes: 35 to 400 mm2.
• Tape, wire or polylam metallic screen.
• Non-armoured or AirbagTM armoured.
• Semi-conducting screen extruded.
Standards
Generally meets the requirements of IEC60502-4, ENEL, CENELEC HD 629-1-2, AS/NZS 4805.1, AS/NZS 4325.1.
Quality assurance
The company has been assessed by third party and found in conformity with the requirements of the standard ISO 9001 – EN 29001.
Installation features
• 100 % electrically tested in the factory.
• No special skills or long experience required.
• Easy assembling.
• No need for special tools or heating.
• Wide cables size range taking.
• Immediate energizing after completion of the joint.
• Great flexibility.
• Suitable and qualified for compact insulated cables.
– COLD SHRINK JOINT
CABLE JOINTS
SEPARABLE ELBOW CONNECTOR ASCA for polymeric cables – Deadbreak operation – Rating 250A
ECOPSEED COLD SHRINK JOINT for Um up to 24kV polymeric cables
PEOT/IJ-1-07/18 Technical information subject
to change without notice
APPLICATION Utilisation
Jointing polymeric insulated cables of different specifications
Conductor sizes equal or unequal May be directly buried Jointing cables laid underground, in tunnels on
horizontal, racks, or aerial Transition joint between extruded and paper insulated
cables
Cables
Single core polymeric insulation Insulation voltage up to 24 kV (Um) Copper or aluminum conductor Conductor sizes: 50 to 630 mm2 Tape, wire or polylam metallic screen Non-armoured or AirbagTM armoured Semi-conducting screen extruded
STANDARDS Generally meets the requirements of IEC 60502-4;
ENEL; CENELEC HD 629-1-2. AS4805.1
QUALITY ASSURANCE The Company has been assessed by third party and found in conformity with the requirements of the standard ISO 9001 - EN 29001.
INSTALLATION FEATURES 100% electrically tested in the factory No special skills or long experience required Easy assembling No need for special tools or heating Wide cables size range taking Immediate energizing after completion of the joint Great flexibility Suitable and qualified for compact insulated cables Technical information subject to change without
notice
REFERENCE: PEOTJ-24 / PEOIJ-24
SELECTION TABLE Cross Section
mm2
With Sealing Tape With Resin Filled
Singe Core Three Cores Singe Core Three Cores
35-150 PEOTJ-1C-24-A PEOTJ-3C-24-A PEOIJ-1C-24-A PEOIJ-3C-24-A
185-500 PEOTJ-1C-24-B PEOTJ-3C-24-B PEOIJ-1C-24-B PEOIJ-3C-24-B
630 PEOTJ-1C-24-C PEOTJ-3C-24-C PEOIJ-1C-24-C PEOIJ-3C-24-C
For armoured cable, please contact our sales for further information.
Plastic net tape and resin
Armoured transparent adhesive PVC tape
Adhesive PVC tapeCopper mesh
Ecospeed joint sleeve High permittivity tape Resin injection valve
Mechanical connector
9www.prysmiancable.com.au | www.prysmiancable.co.nz
CABLE JOINTS
SELECTION GUIDE – ECOSPEED™
PEOTJ – sealing tape PEOIJ – resin filled
12 kVProduct code
12 kVProduct code
Single core Three core Single core Three core
95-150 PEOTJ-1C-12-A-T3 PEOTJ-3C-12-A-T3 95-150 PEOIJ-1C-12-A-T3 PEOIJ-3C-12-A-T3
185-240 PEOTJ-1C-12-B-T3 PEOTJ-3C-12-B-T3 185-240 PEOIJ-1C-12-B-T3 PEOIJ-3C-12-B-T3
300-400 PEOTJ-1C-12-C-T3 PEOTJ-3C-12-C-T3 300-400 PEOIJ-1C-12-C-T3 PEOIJ-3C-12-C-T3
24 kV Single core Three core 24 kV Single core Three core
35-70 PEOTJ-1C-24-A-T3 PEOTJ-3C-24-A-T3 35-70 PEOIJ-1C-24-A-T3 PEOIJ-3C-24-A-T3
95-240 PEOTJ-1C-24-B-T3 PEOTJ-3C-24-B-T3 95-240 PEOIJ-1C-24-B-T3 PEOIJ-3C-24-B-T3
300-400 PEOTJ-1C-24-C-T3 PEOTJ-3C-24-C-T3 300-400 PEOIJ-1C-24-C-T3 PEOIJ-3C-24-C-T3
36 kV Single core Three core 36 kV Single core Three core
95-300 PEOTJ-1C-36-C-T3 PEOTJ-3C-36-C-T3 95-300 PEOIJ-1C-36-C-T3 PEOIJ-3C-36-C-T3
11www.prysmiancable.com.au | www.prysmiancable.co.nz
TERMINATIONS
TERMFIT™ – COLD SHRINK TERMINATION
Description
Indoor/outdoor cold shrink termination for polymeric cables up to 36 kV.
Utilisation
• For connection of polymeric MV cables to overhead link, air insulated switchgear and transformers, etc.
Cables
• Single core or three core polymeric insulation (PE, XLPE, EPR).
• Copper or aluminium conductors, solid or stranded.
• Semi-conducting screen either extruded or taped.
• Metallic screen of tape, wire or polylam type.
• Insulation voltage up to 36 kV.
• Conductor sizes: 35 to 630 mm2.
• With armour layer or without armour layer.
Standards
Generally meets the requirements of IEC60502-4, GB/T12076.4, AS/NZS 4805.1, AS/NZS 4325.1
Quality assurance
The company has been assessed by third party and found in conformity with the requirements of the standard ISO 9001 – EN 29001.
Installation features
• No need for special tools, no heating or filling.
• Vertical, angled or inverted position.
• Energizing may take place immediately after completion of termination.
– COLD SHRINK TERMINATION
CABLE TERMINATIONS
SEPARABLE ELBOW CONNECTOR ASCA for polymeric cables – Deadbreak operation – Rating 250A
INDOOR/OUTDOOR COLD SHRINK TERMINATION for polymeric cables up to 36kV
PCT-1-07/18Technical information subject
to change without notice
APPLICATION
Utilisation
For connection of polymeric MV cables to overhead link, air insulated switchgear and transformers, etc.
Cables
Single core or three core polymeric insulation (PE, XLPE, EPR ...).
Copper or aluminium conductors, solid or stranded. Semi-conducting screen either extruded or taped. Metallic screen of tape, wire or polylam type. Insulation voltage up to 36 kV. Conductor sizes: 25 to 630 mm2. With armour layer or without armour layer.
STANDARDS Generally meets the requirements of IEC60502-4,
GB/T12076.4 - AS4805.1, AS/NZS 4325.1
QUALITY ASSURANCE The Company has been assessed by third party and found in conformity the requirements of the standard ISO 9001 - EN 29001.
SELECTION TABLE
REFERENCE:INDOOR TERMINATION: PCTIOUTDOOR TERMINAITON: PCTO
Voltage Level (kV)
Cross section (mm2)
Indoor Termination Outdoor Termination Single Core Three Cores Single Core Three Cores
24
25-50 PCTI-1C-24-G PCTI-3C-24-G PCTO-1C-24-G PCTO-3C-24-G 70-120 PCTI-1C-24-H PCTI-3C-24-H PCTO-1C-24-H PCTO-3C-24-H
150-240 PCTI-1C-24-I PCTI-3C-24-I PCTO-1C-24-I PCTO-3C-24-I 300-400 PCTI-1C-24-J PCTI-3C-24-J PCTO-1C-24-J PCTO-3C-24-J 500-630 PCTI-1C-24-K PCTI-3C-24-K PCTO-1C-24-K PCTO-3C-24-K
36 25-120 PCTI-1C-36-L PCTI-3C-36-L PCTO-1C-36-L PCTO-3C-36-L
150-300 PCTI-1C-36-M PCTI-3C-36-M PCTO-1C-36-M PCTO-3C-36-M 400-630 PCTI-1C-36-O PCTI-3C-36-O PCTO-1C-36-O PCTO-3C-36-O
INSTALLATION FEATURES
No need for special tools, no heating or filling. Vertical, angled or inverted position. Energizing may take place immediately after
completion of termination.
Cable Lug
Cold ShrinkTermination Sleeve
Cold Shrink Core Sleeve
Cold Shrink Breakout
Cable lug
Cold shrink termination sleeve
Cold shrink core sleeve
Cold shrink breakout
12 www.prysmiancable.com.au | www.prysmiancable.co.nz
CABLE TERMINATIONS
SELECTION GUIDE – TERMFIT™
PCTI – Indoor termination PCTO – Outdoor termination
12 kVProduct code
12 kVProduct code
Single core Three core Single core Three core
35-50 PCTI-1C-12-A-T3 PCTI-3C-12-A-T3 35-50 PCTO-1C-12-A-T3 PCTO-3C-12-A-T3
70-120 PCTI-1C-12-B-T3 PCTI-3C-12-B-T3 70-120 PCTO-1C-12-B-T3 PCTO-3C-12-B-T3
150-185 PCTI-1C-12-C-T3 PCTI-3C-12-C-T3 150-185 PCTO-1C-12-C-T3 PCTO-3C-12-C-T3
240-300 PCTI-1C-12-D-T3 PCTI-3C-12-D-T3 240-300 PCTO-1C-12-D-T3 PCTO-3C-12-D-T3
400-630 PCTI-1C-12-E-T3 PCTI-3C-12-E-T3 400-630 PCTO-1C-12-E-T3 PCTO-3C-12-E-T3
24 kV Single core Three core 24 kV Single core Three core
35-50 PCTI-1C-24-G-T3 PCTI-3C-24-G-T3 35-50 PCTO-1C-24-G-T3 PCTO-3C-24-G-T3
70-150 PCTI-1C-24-H-T3 PCTI-3C-24-H-T3 70-150 PCTO-1C-24-H-T3 PCTO-3C-24-H-T3
185-300 PCTI-1C-24-I-T3 PCTI-3C-24-I-T3 185-300 PCTO-1C-24-I-T3 PCTO-3C-24-I-T3
400-500 PCTI-1C-24-J-T3 PCTI-3C-24-J-T3 400-500 PCTO-1C-24-J-T3 PCTO-3C-24-J-T3
630 PCTI-1C-24-K-T3 PCTI-3C-24-K-T3 630 PCTO-1C-24-K-T3 PCTO-3C-24-K-T3
36 kV Single core Three core 36 kV Single core Three core
35-150 PCTI-1C-36-L-T3 PCTI-3C-36-L-T3 35-150 PCTO-1C-36-L-T3 PCTO-3C-36-L-T3
185-300 PCTI-1C-36-M-T3 PCTI-3C-36-M-T3 185-300 PCTO-1C-36-M-T3 PCTO-3C-36-M-T3
400-630 PCTI-1C-36-N-T3 PCTI-3C-36-N-T3 400-630 PCTO-1C-36-N-T3 PCTO-3C-36-N-T3
13www.prysmiancable.com.au | www.prysmiancable.co.nz
CONNECTORS
15www.prysmiancable.com.au | www.prysmiancable.co.nz
16 www.prysmiancable.com.au | www.prysmiancable.co.nz
Description
Separable straight connector with mechanical conductor contact. For polymeric medium voltage (MV) cables up to 12.7/22 (24) kV. Rating 250 A – Interface A.
Utilisation
• For connection to transformers, switch gear units, motors, etc.
• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.
• Continuous 250 A rms
• Overload 300 A rms (8 hours per 24-hour period).
• Dead-break operated.
• Voltage detection through an integrated capacitive voltage divider.
Cables
• Single core polymeric insulation (PE, XLPE, EPR).
• Copper or aluminium conductor, solid or stranded.
• Semi-conducting screen either extruded or taped.
• Metallic screen of copper tape, copper wires or polylam type.
• Insulation voltage up to 12.7/22 (24) kV.
• Conductor sizes: 25 to 95 mm². For cables with other sizes, please contact us.
Standards
Generally meets the requirements of CENELEC HD 629.1 S2, IEC 60502-4, C 33-051, C 33-001.
Interfaces: CENELEC EN 50180 & EN 50181.
Mechanical conductor contact: IEC 61238-1 class A.
Packing
Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx.) of kit: 3 kg/0.006 m3.
Other products
• Associated products such as bushing FMBOm-250, FMBOh-250 for separable connectors 250 A and accessories interface A.
• Separable elbow connector MSCE/EC-250-A.
Installation features
• For voltage class 24 kV, one product reference only allows to cover cross from 25 mm² to 95 mm², copper or aluminium conductor.
• No need for special tools, no heating, taping or filling.
• Vertical, angled or inverted position.
• No minimum distance between phases.
• Individual clamping by stainless steel brace.
• The three phases may also be locked together and to the equipment by use of metallic rings (supplied on request, separately or already fitted onto the molded groove).
• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug.
• An unplugged connector must never be energized.
STRAIGHT CONNECTOR – MSCS/EC-250-A
DEADBREAK SEPARABLE CONNECTORS
A mark of
FT N
°358
Sep
arab
le S
trai
ght C
onne
ctor
MSC
S EC
250
- V2
May
201
8
Medium Voltage (MV)Up to 12.7/22 (24) kVMV separable connectors rating 250 A (interface A) Reference : MSCS/EC-250-A
Separable straight connector with mechanical conductor contact(interface A / 250 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of CENELEC HD 629.1 S2 - IEC 60502-4 - C 33-051 - C 33-001 Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A
1/3
EC
INTERFACEA/250 A
Prysmian Group Sales department - mail : [email protected]
Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 250 A rms overload 300 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.
Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 12.7/22 (24) kV.• Conductor sizes: 25 to 95 mm².
Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 3 kg / 0,006 m3.
Other products• Associated products such as bushing FMBOm-250, FMBOh-250 for separable connectors 250 A and accessories interface A.• Separable elbow connector MSCE/EC-250-A.
Product Application and Design
A mark of
FT N
°358
Sep
arab
le S
trai
ght C
onne
ctor
MSC
S EC
250
- V2
May
201
8
Medium Voltage (MV)Up to 12.7/22 (24) kVMV separable connectors rating 250 A (interface A) Reference : MSCS/EC-250-A
Separable straight connector with mechanical conductor contact(interface A / 250 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of CENELEC HD 629.1 S2 - IEC 60502-4 - C 33-051 - C 33-001 Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A
1/3
EC
INTERFACEA/250 A
Prysmian Group Sales department - mail : [email protected]
Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 250 A rms overload 300 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.
Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 12.7/22 (24) kV.• Conductor sizes: 25 to 95 mm².
Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 3 kg / 0,006 m3.
Other products• Associated products such as bushing FMBOm-250, FMBOh-250 for separable connectors 250 A and accessories interface A.• Separable elbow connector MSCE/EC-250-A.
Product Application and Design
17www.prysmiancable.com.au | www.prysmiancable.co.nz
SELECTION GUIDE – MSCS/EC-250-A
VoltageUm
Diameter over insulation (mm) Conductor size (mm2)*1
Kit referenceMin. Max. Min. Max.
12 kV 11.8 23.2 25 95 MSCS/EC-250-A-12-25/95*2
17 kV 11.8 23.2 25 95 MSCS/EC-250-A-17-25/95*2
24 kV 17.2 25.0 25 95 MSCS/EC-250-A-24-25/95
*1 For guidance only. *2 Models with adapters.
EARTHING DEVICE
Type of metallic screen of cable Reference
Polyam T1
Copper tape T2
Copper wires T3
INTERFACE FOR SEPARABLE CONNECTORS – TYPE A
According to CENELEC EN 50180 & EN 50181. Medium Voltage (MV)
Insulator voltage: 24 kV
A mark of
FT N
°334
Inte
rfac
es fo
r sep
arab
le c
onne
ctor
s -
May
201
8
Medium Voltage (MV)Up to 36 kV
R E A C H
Interfaces for separable connectors
1/1
According CENELEC* EN 50180 et EN 50181
Type A B2 C1 D1/D2 E1/E2Z
(Propre à PRYSMIAN)
Drawings
Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1Bore
Ø 7,9 mm, Depth:32 mm
BoreØ 14 mm,
Depth: 40 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm
D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm
D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm
Utilisation250 ASliding contact12 & 24 kV
400 ASliding contact12,24&36kV
630 ABolted contact12,24 & 36 kV
1250 ABolted contact12 & 24 kV
1250 ABolted contact36 kV
630 ABolted contact12,24 & 36 kVSpecial interface
Remarks Same dimensions as interface C
Same dimen-sions as Inter-face B
N.A in Prysmian product range
Profile identical to the interface C, but shortened (the angle is the same)
* Except for Interface Z which is a Prysmian specific size
Prysmian Group Sales department - mail : [email protected]
© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
Continuous current: 250 A
D1 Bore: Ø 7.9 mm, depth 32 mm
D2 Ø 31 mm
D3 Ø 32.5 mm
D4 Ø 48.5 mm
L1 48 mm
Utilisation250 A Sliding contact 12 & 24 kV
1. Select the kit corresponding to the insulation voltage Um
in kV and to the diameter over cable insulation.
2. Select suitable earthing device.
Example: 1x50 mm², 22 kV polymeric cable, diameter over insulation 21.5 mm, with copper wire screen, aluminium conductor: MSCS/EC-250-A-24-T3-25/95.
DEADBREAK SEPARABLE CONNECTORS
18 www.prysmiancable.com.au | www.prysmiancable.co.nz
Description
Separable straight connector with mechanical conductor contact. For polymeric medium voltage (MV) cables up to 19/33 (36) kV. Rating 400 A – Interface B.
Utilisation
• For connection to transformers, switch gear units, motors, etc.
• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.
• Continuous 400 A rms.
• Overload 600 A rms (8 hours per 24-hour period).
• Dead-break operated.
• Voltage detection through an integrated capacitive voltage divider.
Cables
• Single core polymeric insulation (PE, XLPE, EPR).
• Copper or aluminium conductor, solid or stranded.
• Semi-conducting screen either extruded or taped.
• Metallic screen of copper tape, copper wires or polylam type.
• Insulation voltage up to 19/33 (36) kV.
• Conductor sizes: 25 to 240 mm². For cables with other sizes, please contact us.
Standards
Generally meets the requirements of CENELEC HD 629.1 S2, IEC 60502-4, IEEE 386, C 33-051.
Interfaces: CENELEC EN 50180 & EN 50181.
Mechanical conductor contact: IEC 61238-1 class A.
Packing
Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx.) of kit: 4.5 kg/0.01 m3.
Other products
• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400 A, interface B.
• Separable elbow connector MSCE/EC-400-B.
Installation features
• The screen break design enables cable outer sheath testing without removing or dismantling the connector.
• No need for special tools, no heating, taping or filling.
• No minimum distance between phases.
• Individual clamping by stainless steel brace.
• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug.
• An unplugged connector must never be energized.
STRAIGHT CONNECTOR – MSCS/EC-400-B
DEADBREAK SEPARABLE CONNECTORS
INTERFACEB/400 A
A mark of
FT N
°359
Sep
arab
le S
trai
ght C
onne
ctor
MSC
S EC
400
- V1
May
201
8
Medium Voltage (MV)Up to 19/33 (36) kVMV separable connectors rating 400 A (interface B) Reference : MSCS/EC-400-B
Separable straight connector with mechanical conductor contact (interface B / 400 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of C 33-051 - CENELEC HD 629.1 S2 – IEC 60502-4 - IEEE 386Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A.
1/3
EC
Prysmian Group Sales department - mail : [email protected]
Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc.• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 400 A rms.• Overload 600 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.
Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductors, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen copper tape, copper wires or polylam type.• Insulation voltage up to 19/33 (36) kV.• Conductor sizes: 25 to 240mm².
Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 4.5 kg / 0.01 m3.
Other products• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400A, interface B.• Separable Elbow Connector MSCE/EC-400-B.
Product Application and Design
A mark of
FT N
°358
Sep
arab
le S
trai
ght C
onne
ctor
MSC
S EC
250
- V2
May
201
8
Medium Voltage (MV)Up to 12.7/22 (24) kVMV separable connectors rating 250 A (interface A) Reference : MSCS/EC-250-A
Separable straight connector with mechanical conductor contact(interface A / 250 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of CENELEC HD 629.1 S2 - IEC 60502-4 - C 33-051 - C 33-001 Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A
1/3
EC
INTERFACEA/250 A
Prysmian Group Sales department - mail : [email protected]
Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 250 A rms overload 300 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.
Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 12.7/22 (24) kV.• Conductor sizes: 25 to 95 mm².
Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 3 kg / 0,006 m3.
Other products• Associated products such as bushing FMBOm-250, FMBOh-250 for separable connectors 250 A and accessories interface A.• Separable elbow connector MSCE/EC-250-A.
Product Application and Design
19www.prysmiancable.com.au | www.prysmiancable.co.nz
SELECTION GUIDE – MSCS/EC-400-B
VoltageUm
Diameter over insulation (mm) Conductor size (mm2)*Kit reference
Min. Max. Min. Max.
12 kV13.0 22.3 25 120 MSCS/EC-400-B-12-rA-25/120
16.1 26.3 95 240 MSCS/EC-400-B-12-rB-95/240
17 kV
13.0 22.3 25 70 MSCS/EC-400-B-17-rA-25/70
16.1 26.3 35 120 MSCS/EC-400-B-17-rB-35/120
20.2 30.8 95 240 MSCS/EC-400-B-17-rC-95/240
24 kV
16.1 26.3 25 150 MSCS/EC-400-B-24-rB-25/150
16.1 26.3 70 185 MSCS/EC-400-B-24-rB-70/185
20.2 30.8 95 240 MSCS/EC-400-B-24-rC-95/240
22.7 33.0 95 240 MSCS/EC-400-B-24-rD-95/240
36 kV
20.2 30.8 25 95 MSCS/EC-400-B-36-rC-25/95
22.7 33.0 35 120 MSCS/EC-400-B-36-rD-35/120
25.6 35.3 70 240 MSCS/EC-400-B-36-rE-70/240
* For guidance only.
INTERFACE FOR SEPARABLE CONNECTORS – TYPE B2
According to CENELEC EN 50180 & EN 50181. Medium Voltage (MV)
Insulator voltage: 36 kV
A mark of
FT N
°334
Inte
rfac
es fo
r sep
arab
le c
onne
ctor
s -
May
201
8
Medium Voltage (MV)Up to 36 kV
R E A C H
Interfaces for separable connectors
1/1
According CENELEC* EN 50180 et EN 50181
Type A B2 C1 D1/D2 E1/E2Z
(Propre à PRYSMIAN)
Drawings
Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1Bore
Ø 7,9 mm, Depth:32 mm
BoreØ 14 mm,
Depth: 40 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm
D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm
D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm
Utilisation250 ASliding contact12 & 24 kV
400 ASliding contact12,24&36kV
630 ABolted contact12,24 & 36 kV
1250 ABolted contact12 & 24 kV
1250 ABolted contact36 kV
630 ABolted contact12,24 & 36 kVSpecial interface
Remarks Same dimensions as interface C
Same dimen-sions as Inter-face B
N.A in Prysmian product range
Profile identical to the interface C, but shortened (the angle is the same)
* Except for Interface Z which is a Prysmian specific size
Prysmian Group Sales department - mail : [email protected]
© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
Continuous current: 400 A
D1 Bore: Ø 14 mm, depth 40 mm
D2 Ø 46 mm
D3 Ø 56 mm
D4 Ø 70 mm
L1 90 mm
Utilisation400 A Sliding contact 12, 24 & 36 kV
1. Select the kit corresponding to the insulation voltage Um
in kV and to the diameter over cable insulation.
2. Select suitable earthing device.
Example: 1x50 mm², 20 kV polymeric cable, diameter over insulation 21.5 mm, with copper wire screen, aluminium conductor: MSCS/EC-400-B-24-rB-T3-25/150.
DEADBREAK SEPARABLE CONNECTORS
EARTHING DEVICE
Type of metallic screen of cable Reference
Polyam T1
Copper tape T2
Copper wires T3
20 www.prysmiancable.com.au | www.prysmiancable.co.nz
INTERFACEB/400 A
A mark of
FT N
°359
Sep
arab
le S
trai
ght C
onne
ctor
MSC
S EC
400
- V1
May
201
8
Medium Voltage (MV)Up to 19/33 (36) kVMV separable connectors rating 400 A (interface B) Reference : MSCS/EC-400-B
Separable straight connector with mechanical conductor contact (interface B / 400 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of C 33-051 - CENELEC HD 629.1 S2 – IEC 60502-4 - IEEE 386Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A.
1/3
EC
Prysmian Group Sales department - mail : [email protected]
Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc.• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 400 A rms.• Overload 600 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.
Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductors, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen copper tape, copper wires or polylam type.• Insulation voltage up to 19/33 (36) kV.• Conductor sizes: 25 to 240mm².
Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 4.5 kg / 0.01 m3.
Other products• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400A, interface B.• Separable Elbow Connector MSCE/EC-400-B.
Product Application and Design
Description
Separable straight connector. For polymeric medium voltage (MV) cables up to 19/33 (36) kV. Rating 400 A – Interface B.
Utilisation
• For connection to transformers, switch gear units, motors, etc.
• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.
• Continuous 400 A rms.
• Overload 600 A rms (8 hours per 24-hour period).
• Dead-break operated.
• Voltage detection through an integrated capacitive voltage divider.
Cables
• Single core polymeric insulation (XLPE).
• Copper or aluminium conductor, solid or stranded.
• Semi-conducting screen either extruded or taped.
• Metallic screen of copper tape, copper wires or polylam type.
• Insulation voltage up to 19/33 (36) kV.
• Conductor sizes: 25 to 300 mm². For cables with other sizes, please contact us.
Standards
Generally meets the requirements of CENELEC HD 629.1 S2, IEC 60502-4, C 33-051.
Interfaces: CENELEC EN 50180 & EN 50181.
Packing
Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 4.5 kg/0.01 m3.
Other products
• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400 A, interface B.
Installation features
• No need for special tools, no heating, taping or filling.
• Vertical, angled or inverted position.
• No minimum distance between phases.
• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug.
• Individual clamping by stainless steel brace.
• An unplugged connector must never be energized.
STRAIGHT CONNECTOR – FMCS-400
DEADBREAK SEPARABLE CONNECTORS
FT N
°345
Sep
arab
le S
trai
ght C
onne
ctor
FM
CS 4
00 -
V1 M
ay 2
018
Medium Voltage (MV)Up to 19/33 (36) kVMV Separable Connectors rating 400A (Interface B) Reference: FMCS-400
Separable straight connector FMCS-400(Interface B / 400A) For polymeric cables -Deadbreak - Operation Generally meets the requirement C 33-051 - HD 629.1.S2 - IEC 60502-4 Interface: CENELEC EN50180 - EN50181
Utilisation• For connection of polymeric MV cables to transformers, switchgear units,
motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a
watertight conductive envelope connected to earth. • Continuous 400 A rms overload 600 A rms (8 hours per 24-hour period). • Dead break operation.• Voltage detection through an integrated capacitive voltage
divider.
Cables• Single core polymeric insulation (XLPE). • Copper or aluminum conductor. • Semi-conducting screen either extruded or taped. • Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 36 kV. • Conductor sizes: 25 mm2 to 300) mm2.
Packing Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 4,5 kg / 0,01 m3
Other products• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400A,
interface B.
1/2
Product Application and Design
INTERFACEB / 400 A
®
Prysmian Group Sales department - mail : [email protected]
A mark of
Installation features• No need for special tools, no heating, taping or filling. • Vertical, angled or inverted position. • No minimum distance between phases. • Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end
plug... • Individual clamping by stainless steel brace.• An unplugged connector must never be energized
21www.prysmiancable.com.au | www.prysmiancable.co.nz
EARTHING DEVICE LUG
Type of metallic screen of cable Reference Type of
conductor Reference
Polyam T1 Copper C + conductor size in mm2
Copper tape T2 Aluminium A + conductor size in mm2
Copper wires T3 Aluminium* + lug for hexagonal crimping required
A + conductor size in mm2
+ DIN
SELECTION GUIDE – FMCS-400
Kit referenceDiameter over insulation
(mm)
Voltage Um
12 kV 17.5 kV 24 kV 36 kV
Conductor size (mm2)*1
Min. Max. Min. Max. Min. Max. Min. Max. Min. Max.
FMCS-400-Z 18.5 20.5 70 95 50 70 35 50 – –
FMCS-400-A 19.9 21.9 95 120 70 95 50 70 – 25
FMCS-400-B 21.4 23.5 120 150 95 120 70 95 25 35
FMCS-400-C 22.9 25.1 150 185 120 150 95 120 35 50
FMCS-400-D 24.4 26.6 185 240 150 185 120 150 50 70
FMCS-400-E 26.0 28.3 240 300* 185 240 150 185 70 95
FMCS-400-F 27.8 30.4 300*2 – 240 300* 185 – 95 120
FMCS-400-G 29.8 32.7 – – 300*2 – 240 240 120/150 150
FMCS-400-H 31.8 35.3 – – – – 300*2 300*2 185 240
FMCS-400-J 34.1 38.3 – – – – – – 240 300*2
*1 For guidance only. *2 For 300 sqmm, please contact us.
Note! For cables with bonded outer semi-conducting layer: carefully check the diameter over insulation after removal of the outer semi-conducting layer.
INTERFACE FOR SEPARABLE CONNECTORS – TYPE B2
According to CENELEC EN 50180 & EN 50181. Medium Voltage (MV)
Insulator voltage: 36 kV
A mark of
FT N
°334
Inte
rfac
es fo
r sep
arab
le c
onne
ctor
s -
May
201
8
Medium Voltage (MV)Up to 36 kV
R E A C H
Interfaces for separable connectors
1/1
According CENELEC* EN 50180 et EN 50181
Type A B2 C1 D1/D2 E1/E2Z
(Propre à PRYSMIAN)
Drawings
Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1Bore
Ø 7,9 mm, Depth:32 mm
BoreØ 14 mm,
Depth: 40 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm
D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm
D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm
Utilisation250 ASliding contact12 & 24 kV
400 ASliding contact12,24&36kV
630 ABolted contact12,24 & 36 kV
1250 ABolted contact12 & 24 kV
1250 ABolted contact36 kV
630 ABolted contact12,24 & 36 kVSpecial interface
Remarks Same dimensions as interface C
Same dimen-sions as Inter-face B
N.A in Prysmian product range
Profile identical to the interface C, but shortened (the angle is the same)
* Except for Interface Z which is a Prysmian specific size
Prysmian Group Sales department - mail : [email protected]
© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
Continuous current: 400 A
D1 Bore: Ø 14 mm, depth 40 mm
D2 Ø 46 mm
D3 Ø 56 mm
D4 Ø 70 mm
L1 90 mm
Utilisation400 A Sliding contact 12, 24 & 36 kV
1. Select the kit corresponding to the diameter over cable insulation.
2. Specify the insulation voltage Um in kV.
3. Select suitable earthing device.
4. Select suitable lug.
Example: 1x95 mm², 33 kV polymeric cable, diameter over insulation 29.3 mm, with copper wire screen, aluminium conductor: FMCS-400-F-36-T3-A95.
DEADBREAK SEPARABLE CONNECTORS
*available for deep indenting a hexagonal crimping. Unless other wise stated, standard delivery will be with deep indenting. Suitable tooling to be used.
22 www.prysmiancable.com.au | www.prysmiancable.co.nz
A mark of
FT N
°360
MSC
E/EC
-250
-A (i
nter
face
A /
250
A) -
V2M
ay 2
018
Medium Voltage (MV)Up to 12.7/22 (24) kVMV separable connectors rating 250 A (interface A) Reference : MSCE/EC -250-A
Separable elbow connector with mechanical conductor contact (interface A / 250 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of CENELEC HD 629.1 S2 - EC 60502-4 - C 33-051 -C 33-001Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A
1/3
EC
INTERFACEA/250 A
Prysmian Group Sales department - mail : [email protected]
Utilisation • For connection of polymeric MV cables to transformers, switchgear units, motors,
etc. • Indoor and outdoor installation. The connector is entirely protected by a watertight
conductive envelope connected to earth. • Continuous 250 A rms. • Overload 300 A rms (8 hours per 24-hour period). • Deadbreak operation.• Voltage detection through an integrated capacitive voltage divider.
Cables • Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminum conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 12.7/22 (24) kV.• Conductor sizes: 25 to 95 mm².
Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 3 kg / 0,006 m3.
Other products• Associated products such as bushing FMBOm-250, FMBOh-250 and accessories for separable connectors 250A, interface B.• Separable straight connector MSCS/EC-250-A.
Product Application and Design
Description
Separable elbow connector with mechanical conductor contact. For polymeric medium voltage (MV) cables up to 12.7/22 (24) kV. Rating 250 A – Interface A.
Utilisation
• For connection to transformers, switch gear units, motors, etc.
• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.
• Continuous 250 A rms
• Overload 300 A rms (8 hours per 24-hour period).
• Dead-break operated.
• Voltage detection through an integrated capacitive voltage divider.
Cables
• Single core polymeric insulation (PE, XLPE, EPR).
• Copper or aluminium conductor, solid or stranded.
• Semi-conducting screen either extruded or taped.
• Metallic screen of copper tape, copper wires or polylam type.
• Insulation voltage up to 12.7/22 (24) kV.
• Conductor sizes: 25 to 95 mm². For cables with other sizes, please contact us.
Standards
Generally meets the requirements of CENELEC HD 629.1 S2, IEC 60502-4, C 33-051, C 33-001.
Interfaces: CENELEC EN 50180 & EN 50181.
Mechanical conductor contact: IEC 61238-1 class A.
Packing
Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 3 kg/0.006 m3.
Other products
• Associated products such as bushing FMBOm-250, FMBOh-250 and accessories for separable connectors 250A, interface A.
• Separable straight connector MSCS/EC-250-A.
Installation features
• For voltage class 24 kV, one product reference only allows to cover cross from 25 mm² to 95 mm², copper or aluminium conductor.
• No need for special tools, no heating, taping or filling.
• Vertical, angled or inverted position.
• No minimum distance between phases.
• Individual clamping by stainless steel brace.
• The three phases may also be locked together and to the equipment by use of metallic rings (supplied on request, separately or already fitted onto the molded groove).
• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug.
• An unplugged connector must never be energized.
ELBOW CONNECTOR – MSCE/EC-250-A
DEADBREAK SEPARABLE CONNECTORS
A mark of
FT N
°358
Sep
arab
le S
trai
ght C
onne
ctor
MSC
S EC
250
- V2
May
201
8
Medium Voltage (MV)Up to 12.7/22 (24) kVMV separable connectors rating 250 A (interface A) Reference : MSCS/EC-250-A
Separable straight connector with mechanical conductor contact(interface A / 250 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of CENELEC HD 629.1 S2 - IEC 60502-4 - C 33-051 - C 33-001 Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A
1/3
EC
INTERFACEA/250 A
Prysmian Group Sales department - mail : [email protected]
Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 250 A rms overload 300 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.
Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 12.7/22 (24) kV.• Conductor sizes: 25 to 95 mm².
Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 3 kg / 0,006 m3.
Other products• Associated products such as bushing FMBOm-250, FMBOh-250 for separable connectors 250 A and accessories interface A.• Separable elbow connector MSCE/EC-250-A.
Product Application and Design
23www.prysmiancable.com.au | www.prysmiancable.co.nz
SELECTION GUIDE – MSCE/EC-250-A
VoltageUm
Diameter over insulation (mm) Conductor size (mm2)*1
Kit referenceMin. Max. Min. Max.
12 kV 11.8 23.2 25 95 MSCE/EC-250-A-12-25/95*2
17 kV 11.8 23.2 25 95 MSCE/EC-250-A-17-25/95*2
24 kV 17.2 25.0 25 95 MSCE/EC-250-A-24-25/95
*1 For guidance only. *2 Models with adapters.
EARTHING DEVICE
Type of metallic screen of cable Reference
Polyam T1
Copper tape T2
Copper wires T3
INTERFACE FOR SEPARABLE CONNECTORS – TYPE A
According to CENELEC EN 50180 & EN 50181. Medium Voltage (MV)
Insulator voltage: 24 kV
A mark of
FT N
°334
Inte
rfac
es fo
r sep
arab
le c
onne
ctor
s -
May
201
8
Medium Voltage (MV)Up to 36 kV
R E A C H
Interfaces for separable connectors
1/1
According CENELEC* EN 50180 et EN 50181
Type A B2 C1 D1/D2 E1/E2Z
(Propre à PRYSMIAN)
Drawings
Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1Bore
Ø 7,9 mm, Depth:32 mm
BoreØ 14 mm,
Depth: 40 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm
D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm
D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm
Utilisation250 ASliding contact12 & 24 kV
400 ASliding contact12,24&36kV
630 ABolted contact12,24 & 36 kV
1250 ABolted contact12 & 24 kV
1250 ABolted contact36 kV
630 ABolted contact12,24 & 36 kVSpecial interface
Remarks Same dimensions as interface C
Same dimen-sions as Inter-face B
N.A in Prysmian product range
Profile identical to the interface C, but shortened (the angle is the same)
* Except for Interface Z which is a Prysmian specific size
Prysmian Group Sales department - mail : [email protected]
© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
Continuous current: 250 A
D1 Bore: Ø 7.9 mm, depth 32 mm
D2 Ø 31 mm
D3 Ø 32.5 mm
D4 Ø 48.5 mm
L1 48 mm
Utilisation250 A Sliding contact 12 & 24 kV
1. Select the kit corresponding to the insulation voltage Um
in kV and to the diameter over cable insulation.
2. Select suitable earthing device.
Example: 1x50 mm², 22 kV polymeric cable, diameter over insulation 21.5 mm, with copper wire screen, aluminium conductor: MSCE/EC-250-A-24-T3-25/95.
DEADBREAK SEPARABLE CONNECTORS
24 www.prysmiancable.com.au | www.prysmiancable.co.nz
Description
Separable elbow connector. For polymeric medium voltage (MV) cables up to 19/33 (36) kV. Rating 400 A – Interface B.
Utilisation
• For connection to transformers, switch gear units, motors, etc.
• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.
• Continuous 400 A rms.
• Overload 600 A rms (8 hours per 24-hour period).
• Dead-break operated.
• Voltage detection through an integrated capacitive voltage divider.
Cables
• Single core polymeric insulation (XLPE).
• Copper or aluminium conductor, solid or stranded.
• Semi-conducting screen either extruded or taped.
• Metallic screen of copper tape, copper wires or polylam type.
• Insulation voltage up to 19/33 (36) kV.
• Conductor sizes: 25 to 240 mm². For cables with other sizes, please contact us.
Standards
Generally meets the requirements of CENELEC HD 629.1 S2, IEC 60502-4, C 33-051, C 33-001.
Interfaces: CENELEC EN 50180 & EN 50181.
Packing
Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 6 kg/0.013 m3.
Other products
• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400 A, interface B.
Installation features
• No need for special tools, no heating, taping or filling.
• Vertical, angled or inverted position.
• No minimum distance between phases.
• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug.
• Individual clamping by stainless steel brace.
• An unplugged connector must never be energized.
ELBOW CONNECTOR – FMCE-400
DEADBREAK SEPARABLE CONNECTORS
FT N
°324
Sep
arab
le E
lbow
Con
nect
or F
MCE
400
- V1
May
201
8
Medium Voltage (MV)Up to 19/33 (36) kVMV Separable connectors rating 400A (Interface B)Rating 400A (interface B) Reference: FMCE 400
A mark of
Separable elbow connector(interface B/400A)For polymeric cables - Deadbreak - OperationGenerally meets the requirements of C 33-051 - C 33-001 - HD629.1 S2 - IEC 60502-4 Interfaces: CENELEC EN 50180 – EN 50181
1/3
INTERFACEB/400A
®
Installation features• No need for special tools, no heating, taping or filling. • Vertical, angled or inverted position. • No minimum distance between phases. • Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end
plug... • Individual clamping by stainless steel brace.• An unplugged connector must never be energized.
Prysmian Group Sales department - mail : [email protected]
Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors,
etc...• Indoor and outdoor installation. The connector is entirely protected by a watertight
conductive envelope connected to earth.• Continuous 400 A rms.
overload 600 A rms (8 hours per 24-hour period).• Voltage detection through an integrated capacitive voltage divider.
Cables• Single core polymeric insulation (XLPE). • Copper or aluminum conductor. • Semi-conducting screen either extruded or taped. • Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 36 kV. • Conductor sizes: 25 mm2 to 240 mm2 (or 300) mm2.
Packing • Supplied as a kit for 3 single connectors containing all the necessary components.
Shipping weight and volume (approx) of kit: 6 kg / 0,013 m3.
Other products• Associated products such as bushing FMBOm-400 and accessories for separable
connectors 400A, interface B.
Product Application and Design
FT N
°345
Sep
arab
le S
trai
ght C
onne
ctor
FM
CS 4
00 -
V1 M
ay 2
018
Medium Voltage (MV)Up to 19/33 (36) kVMV Separable Connectors rating 400A (Interface B) Reference: FMCS-400
Separable straight connector FMCS-400(Interface B / 400A) For polymeric cables -Deadbreak - Operation Generally meets the requirement C 33-051 - HD 629.1.S2 - IEC 60502-4 Interface: CENELEC EN50180 - EN50181
Utilisation• For connection of polymeric MV cables to transformers, switchgear units,
motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a
watertight conductive envelope connected to earth. • Continuous 400 A rms overload 600 A rms (8 hours per 24-hour period). • Dead break operation.• Voltage detection through an integrated capacitive voltage
divider.
Cables• Single core polymeric insulation (XLPE). • Copper or aluminum conductor. • Semi-conducting screen either extruded or taped. • Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 36 kV. • Conductor sizes: 25 mm2 to 300) mm2.
Packing Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 4,5 kg / 0,01 m3
Other products• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400A,
interface B.
1/2
Product Application and Design
INTERFACEB / 400 A
®
Prysmian Group Sales department - mail : [email protected]
A mark of
Installation features• No need for special tools, no heating, taping or filling. • Vertical, angled or inverted position. • No minimum distance between phases. • Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end
plug... • Individual clamping by stainless steel brace.• An unplugged connector must never be energized
25www.prysmiancable.com.au | www.prysmiancable.co.nz
EARTHING DEVICE LUG
Type of metallic screen of cable Reference Type of
conductor Reference
Polyam T1 Copper C + conductor size in mm2
Copper tape T2 Aluminium A + conductor size in mm2
Copper wires T3 Aluminium* + lug for hexagonal crimping required
A + conductor size in mm2
+ DIN
SELECTION GUIDE – FMCE-400
Kit referenceDiameter over insulation
(mm)
Voltage Um
12 kV 17.5 kV 24 kV 36 kV
Conductor size (mm2)*1
Min. Max. Min. Max. Min. Max. Min. Max. Min. Max.
FMCE-400-Z 18.5 20.5 70 95 50 70 35 50 – –
FMCE-400-A 19.9 21.9 95 120 70 95 50 70 – 25
FMCE-400-B 21.4 23.5 120 150 95 120 70 95 25 35
FMCE-400-C 22.9 25.1 150 185 120 150 95 120 35 50
FMCE-400-D 24.4 26.6 185 240 150 185 120 150 50 70
FMCE-400-E 26.0 28.3 240 300* 185 240 150 185 70 95
FMCE-400-F 27.8 30.4 300*2 – 240 300*2 185 – 95 120
FMCE-400-G 29.8 32.7 – – – – 240 240 120/150 150
FMCE-400-H 31.8 35.3 – – – – 300*2 300*2 185 240
FMCE-400-J 34.1 38.3 – – – – – – 240 300*2
*1 For guidance only. *2 For 300 sqmm, please contact us.
Note! For cables with bonded outer semi-conducting layer: carefully check the diameter over insulation after removal of the outer semi-conducting layer.
INTERFACE FOR SEPARABLE CONNECTORS – TYPE B2
According to CENELEC EN 50180 & EN 50181. Medium Voltage (MV)
Insulator voltage: 36 kV
A mark of
FT N
°334
Inte
rfac
es fo
r sep
arab
le c
onne
ctor
s -
May
201
8
Medium Voltage (MV)Up to 36 kV
R E A C H
Interfaces for separable connectors
1/1
According CENELEC* EN 50180 et EN 50181
Type A B2 C1 D1/D2 E1/E2Z
(Propre à PRYSMIAN)
Drawings
Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1Bore
Ø 7,9 mm, Depth:32 mm
BoreØ 14 mm,
Depth: 40 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm
D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm
D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm
Utilisation250 ASliding contact12 & 24 kV
400 ASliding contact12,24&36kV
630 ABolted contact12,24 & 36 kV
1250 ABolted contact12 & 24 kV
1250 ABolted contact36 kV
630 ABolted contact12,24 & 36 kVSpecial interface
Remarks Same dimensions as interface C
Same dimen-sions as Inter-face B
N.A in Prysmian product range
Profile identical to the interface C, but shortened (the angle is the same)
* Except for Interface Z which is a Prysmian specific size
Prysmian Group Sales department - mail : [email protected]
© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
Continuous current: 400 A
D1 Bore: Ø 14 mm, depth 40 mm
D2 Ø 46 mm
D3 Ø 56 mm
D4 Ø 70 mm
L1 90 mm
Utilisation400 A Sliding contact 12, 24 & 36 kV
1. Select the kit corresponding to the diameter over cable insulation.
2. Specify the insulation voltage Um in kV.
3. Select suitable earthing device.
4. Select suitable lug.
Example: 1x95 mm², 33 kV polymeric cable, diameter over insulation 29.5 mm, with copper wire screen, aluminium conductor: FMCE-400-F-36-T3-A95.
DEADBREAK SEPARABLE CONNECTORS
*available for deep indenting a hexagonal crimping. Unless other wise stated, standard delivery will be with deep indenting. Suitable tooling to be used.
26 www.prysmiancable.com.au | www.prysmiancable.co.nz
A mark of
FT N
°362
Sep
arab
le T
ee C
onne
ctor
MSC
T EC
630
C -
V1 M
ay 2
018
Medium Voltage (MV)Up to 19/33 (36) kVMV separable connectors rating 630 A (interface C) Reference : MSCT/EC-630-C
Separable elbow connector with mechanical conductor contact (interface C / 630 A)For polymeric cables – Deadbreak operation Generally meets the requirements of C 33-051 - CENELEC HD 629.1 S2 – IEC 60502-4Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A.
1/4
EC
INTERFACEC/630 A
Installation features• The screen break design enables cable outer sheath testing without removing or dismantling the connector.• No need for special tools, no heating, taping or filling.• Vertical, angled or inverted position.• No minimum distance between phases.• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug . • An unplugged connector must never be energized.
Prysmian Group Sales department - mail : [email protected]
UtilisationFor connection of polymeric MV cables to transformers, switchgear units,motors, etc.• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 630 A rms.• Overload 900 A rms (8 hours per 24-hour period).• Deadbreak operation.• Voltage detection through an integrated capacitive voltage divider.
Cable• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 19/33 (36) kV.• Conductor sizes: 25 to 300 mm².
Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 6 kg / 0,013 m3.
Other productsAssociated products such as bushing FMBOS 400 and accessories for separable connectors 630A, interface C.
Product Application and Design
•
Description
Separable tee connector with mechanical conductor contact. For polymeric medium voltage (MV) cables up to 19/33 (36) kV. Rating 630 A – Interface C.
Utilisation
• For connection to transformers, switch gear units, motors, etc.
• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.
• Continuous 630 A rms.
• Overload 900 A rms (8 hours per 24-hour period).
• Dead-break operated.
• Voltage detection through an integrated capacitive voltage divider.
Cables
• Single core polymeric insulation (PE, XLPE, EPR).
• Copper or aluminium conductor, solid or stranded.
• Semi-conducting screen either extruded or taped.
• Metallic screen of copper tape, copper wires or polylam type.
• Insulation voltage up to 19/33 (36) kV.
• Conductor sizes: 25 to 300 mm². For cables with other sizes, please contact us.
Standards
Generally meets the requirements of CENELEC HD 629.1 S2, IEC 60502-4, C 33-051.
Interfaces: CENELEC EN 50180 & EN 50181.
Mechanical conductor contact: IEC 61238-1 class A.
Packing
Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 6 kg/0.013 m3.
Other products
• Associated products such as bushing FMBOm-400 and accessories for separable connectors 630 A, interface C.
Installation features
• The screen break design enables cable outer sheath testing without removing or dismantling the connector.
• No need for special tools, no heating, taping or filling.
• Vertical, angled or inverted position.
• No minimum distance between phases.
• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug.
• An unplugged connector must never be energized.
TEE CONNECTOR – MSCT/EC-630-C
DEADBREAK SEPARABLE CONNECTORS
A mark of
FT N
°358
Sep
arab
le S
trai
ght C
onne
ctor
MSC
S EC
250
- V2
May
201
8
Medium Voltage (MV)Up to 12.7/22 (24) kVMV separable connectors rating 250 A (interface A) Reference : MSCS/EC-250-A
Separable straight connector with mechanical conductor contact(interface A / 250 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of CENELEC HD 629.1 S2 - IEC 60502-4 - C 33-051 - C 33-001 Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A
1/3
EC
INTERFACEA/250 A
Prysmian Group Sales department - mail : [email protected]
Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 250 A rms overload 300 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.
Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 12.7/22 (24) kV.• Conductor sizes: 25 to 95 mm².
Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 3 kg / 0,006 m3.
Other products• Associated products such as bushing FMBOm-250, FMBOh-250 for separable connectors 250 A and accessories interface A.• Separable elbow connector MSCE/EC-250-A.
Product Application and Design
27www.prysmiancable.com.au | www.prysmiancable.co.nz
INTERFACE FOR SEPARABLE CONNECTORS – TYPE C1
According to CENELEC EN 50180 & EN 50181. Medium Voltage (MV)
Insulator voltage: 36 kV
A mark of
FT N
°334
Inte
rfac
es fo
r sep
arab
le c
onne
ctor
s -
May
201
8
Medium Voltage (MV)Up to 36 kV
R E A C H
Interfaces for separable connectors
1/1
According CENELEC* EN 50180 et EN 50181
Type A B2 C1 D1/D2 E1/E2Z
(Propre à PRYSMIAN)
Drawings
Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1Bore
Ø 7,9 mm, Depth:32 mm
BoreØ 14 mm,
Depth: 40 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm
D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm
D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm
Utilisation250 ASliding contact12 & 24 kV
400 ASliding contact12,24&36kV
630 ABolted contact12,24 & 36 kV
1250 ABolted contact12 & 24 kV
1250 ABolted contact36 kV
630 ABolted contact12,24 & 36 kVSpecial interface
Remarks Same dimensions as interface C
Same dimen-sions as Inter-face B
N.A in Prysmian product range
Profile identical to the interface C, but shortened (the angle is the same)
* Except for Interface Z which is a Prysmian specific size
Prysmian Group Sales department - mail : [email protected]
© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
Continuous current: 630 A
D1 Thread: M16, depth 29 mm
D2 Ø 46 mm
D3 Ø 56 mm
D4 Ø 70 mm
L1 90 mm
Utilisation630 A Bolted contact 12, 24 & 36 kV
SELECTION GUIDE – MSCT/EC-630-C
VoltageUm
Diameter over insulation (mm) Conductor size (mm2)*Kit reference
Min. Max. Min. Max.
12 kV
13.0 22.3 25 120 MSCT/EC-630-C-12-rA-25/120
16.1 26.3 95 240 MSCT/EC-630-C-12-rB-95/240
22.7 33.0 185 300 MSCT/EC-630-C-12-rD-185/300
17 kV
13.0 22.3 25 70 MSCT/EC-630-C-17-rA-25/70
16.1 26.3 35 120 MSCT/EC-630-C-17-rB-35/120
20.2 30.8 95 240 MSCT/EC-630-C-17-rC-95/240
25.6 35.3 185 300 MSCT/EC-630-C-17-rE-185/300
24 kV
16.1 26.3 25 150 MSCT/EC-630-C-24-rB-25/150
16.1 26.3 70 150 MSCT/EC-630-C-24-rB-70/150
20.2 30.8 95 240 MSCT/EC-630-C-24-rC-95/240
22.7 33.0 95 240 MSCT/EC-630-C-24-rD-95/240
25.6 35.3 185 300 MSCT/EC-630-C-24-rE-185/300
36 kV
20.2 30.8 25 95 MSCT/EC-630-C-36-rC-25/95
22.7 33.1 35 120 MSCT/EC-630-C-36-rD-35/120
25.6 35.3 70 240 MSCT/EC-630-C-36-rE-70/240
30.5 40.6 150 300 MSCT/EC-630-C-36-rF-150/300
* For guidance only.
1. Select the kit corresponding to the insulation voltage Um
in kV and to the diameter over cable insulation.
2. Select suitable earthing device.
Example: 1x95 mm², 20 kV polymeric cable, diameter over insulation 21.5 mm, with copper wire screen, aluminium conductor: MSCT/EC-630-C-24-rC-T3-95/240.
DEADBREAK SEPARABLE CONNECTORS
EARTHING DEVICE
Type of metallic screen of cable Reference
Polyam T1
Copper tape T2
Copper wires T3
Sep
arab
le C
onn
ecto
rsA
CC
ES
SO
RIE
S F
OR
40
0A
TE
E C
ON
NE
CT
OR
S
Section 5 :Seperable Connectors
All
pri
ces
are
sub
ject
to
our
Ter
ms
and
Co
ndit
ions
of
Sal
e -
see
insi
de
fro
nt c
ove
r fo
r m
ore
det
ails
Pag
e 69
Prod
ucts
with
pric
es in
BO
LDar
e m
ade
to o
rder
and
are
sub
ject
to a
min
imum
ord
er q
uant
ity •
All
othe
r ite
ms
are
norm
ally
exs
tock
, sub
ject
to re
mai
ning
uns
old.
Con
firm
atio
n w
ill be
mad
e at
tim
e of
ord
er
INSU
LATI
NG P
LUG
Expo
xy re
sin
mou
ld w
hich
pro
vide
s de
ad-e
nd fa
cilit
y fo
r sep
arab
le te
e co
nnec
tors
.
Insu
latin
g P
lug
12
kV
- r
atin
g 4
00
AF
MP
I-4
00
-12
29
.23
Insu
latin
g P
lug
24
kV
- r
atin
g 4
00
AF
MP
I-4
00
-24
29
.23
De
sc
rip
tio
nR
ef.
No
.P
ric
e £
ea
ch
Sta
nd
Off
Plu
g 1
2kV
- r
atin
g 4
00
AF
MP
S-4
00
-12
12
1.6
0
Sta
nd
Off
Plu
g 2
4kV
- r
atin
g 4
00
AF
MP
S-4
00
-24
12
1.6
0
De
sc
rip
tio
nR
ef.
No
.P
ric
e £
ea
ch
STAN
D OF
F PL
UGED
PM m
ould
ing
whi
ch is
des
igne
d to
pro
ivde
sup
port
and
dead
-end
sep
arab
le c
onne
ctor
whe
n re
mov
ed fr
om th
e eq
uipm
ent.
Str
aig
ht
Co
nn
ectio
n P
lug
12
kV
- r
atin
g 4
00
AF
MP
Cs-4
00
-12
14
1.2
0
Str
aig
ht
Co
nn
ectio
n P
lug
24
kV
- r
atin
g 4
00
AF
MP
Cs-4
00
-24
14
1.2
0
De
sc
rip
tio
nR
ef.
No
.P
ric
e £
ea
ch
STRA
IGHT
CON
NECT
ION
PLUG
Expo
xy re
sin
mou
ldin
g ov
er a
cop
per r
od fo
r con
nect
ing
two
sepa
rabl
e te
e co
nnec
tors
FM
CTs-
400.
Ea
rth
ing
Plu
g -
ra
tin
g 4
00
AF
MP
E-4
00
22
8.3
3
De
sc
rip
tio
nR
ef.
No
.P
ric
e £
ea
ch
EART
HING
PLU
GED
PM m
ould
ing
desi
gned
to s
uppo
rt an
d ea
rth s
epar
able
con
nect
ors
whe
n re
mov
ed fr
om th
e eq
uipm
ent.
12
05
0F
MC
Ts-6
00
/12
50
-A2
08
.92
15
07
0F
MC
Ts-6
00
/12
50
-B2
12
.18
-9
5F
MC
Ts-6
00
/12
50
-C2
09
.64
18
51
20
FM
CT
s-6
00
/12
50
-D2
12
.18
24
01
50
FM
CT
s-6
00
/12
50
-E2
08
.92
30
01
85
FM
CT
s-6
00
/12
50
-G2
09
.64
-2
40
FM
CT
s-6
00
/12
50
-H2
08
.92
40
03
00
FM
CT
s-6
00
/12
50
-J2
14
.76
50
04
00
FM
CT
s-6
00
/12
50
-L2
14
.76
63
0-
FM
CT
s-6
00
/12
50
-M2
21
.47
-5
00
FM
CT
s-6
00
/12
50
-N2
22
.15
-6
30
FM
CT
s-6
00
/12
50
-Q2
21
.47
Co
nd
uc
tor
Siz
e
mm
2 1
2k
V
Co
nd
uc
tor
Siz
e
mm
2 2
4k
VR
ef.
No
.P
ric
e £
ea
ch
SEPA
RABL
E TE
E CO
NNEC
TORS
TEE
CONN
ECTO
RTo
sui
t pol
ymer
ic c
able
s up
to 2
4kV
- non
-load
brea
k op
erat
ion
- rat
ing
1250
A (w
ith c
lam
ping
scr
ew).
Volta
ge C
lass
: kV
Earth
ing
Kit :
T1
(Pol
ylam
) T2
(Cop
per T
ape)
T3
(Cop
per W
ire)
Cond
ucto
r Typ
e an
d si
ze in
mm
2: “
A”(A
lum
iniu
m) -
mm
2 "C
" (C
oppe
r) - m
m2
To s
elec
t - R
ef.n
o +
Volta
ge c
lass
+ E
arth
ing
kit +
Con
duct
or ty
pe &
siz
e m
m2
Note
: Ty
pica
l exa
mpl
e fo
r a 2
4kV
tee
conn
ecto
r for
300
mm
2 ,cop
per w
iresc
reen
cab
le a
lum
iniu
m c
ondu
ctor
: FM
CTs-
600/
1250
-J-2
4-T3
-A30
0Sep
arab
le C
onn
ecto
rsA
CC
ES
SO
RIE
S F
OR
40
0A
& 6
00
/12
50
A T
EE
CO
NN
EC
TO
RS
www.pirelli.co.uk
Pag
e 70
Pire
lli C
ompo
nent
s U
nit
Com
mer
cial
Enq
uirie
s:te
l 015
1 43
0 36
55
fax
0151
430
363
6
No
rma
l B
ush
ing
- 1
2kV
ra
tin
g 6
00
/12
50
A in
oil
FM
BO
s-6
00
/12
50
-12
14
3.9
6
No
rma
l B
ush
ing
- 2
4kV
ra
tin
g 6
00
/12
50
A in
oil
FM
BO
s-6
00
/12
50
-24
14
3.9
6
De
sc
rip
tio
nR
ef.
No
.P
ric
e £
ea
ch
CABL
E BU
SHIN
GSFo
r use
in o
il ap
plic
atio
ns u
p to
24k
V - n
on-lo
adbr
eak
oper
atio
n - r
atin
g 60
0/12
50A
(scr
ew c
onta
ct).
ACCE
SSOR
IES
FOR
600/
1250
A TE
E CO
NNEC
TORS
Str
aig
ht
Co
nn
ectio
n P
lug
12
kV
- r
atin
g 6
00
/12
50
A
FM
PC
s-6
00
/12
50
-12
13
2.3
0
Str
aig
ht
Co
nn
ectio
n P
lug
24
kV
- r
atin
g 6
00
/12
50
AF
MP
Cs-6
00
/12
50
-24
13
2.3
0
De
sc
rip
tio
nR
ef.
No
.P
ric
e £
ea
ch
STRA
IGHT
CON
NECT
ION
PLUG
Expo
xy re
sin
mou
ldin
g ov
er a
cop
per r
od fo
r con
nect
ing
two
sepa
rabl
e te
e co
nnec
tors
.
Insu
latin
g P
lug
12
kV
- r
atin
g 6
00
/12
50
AF
MP
I-6
00
/12
50
-12
41
.90
Insu
latin
g P
lug
24
kV
- r
atin
g 6
00
/12
50
AF
MP
I-6
00
/12
50
-24
41
.90
De
sc
rip
tio
nR
ef.
No
.P
ric
e £
ea
ch
INSU
LATI
NG P
LUG
Epox
y re
sin
mou
ld w
hich
pro
vide
s de
ad-e
nd fa
cilit
y fo
r sep
arab
le te
e co
nnec
tors
.
Re
du
cin
g P
lug
12
kV
- r
atin
g 6
00
AF
MP
R-6
00
-12
18
1.2
0
Re
du
cin
g P
lug
24
kV
ra
tin
g 6
00
AF
MP
R-6
00
-24
18
1.2
0
De
sc
rip
tio
nR
ef.
No
.P
ric
e £
ea
ch
REDU
CING
PLU
G FM
PR -6
00Ep
oxy
resi
n m
ould
whi
ch a
llow
s a
sepa
rabl
e te
e co
nnec
tor F
MCT
s-60
0/12
50 to
acc
ept c
onne
ctor
s of
the
250A
ser
ies.
Separable ConnectorsT E E C O N N E C T O R S & A C C E S S O R I E S F O R 4 0 0 A T E E C O N N E C T O R S
ww
w.p
ire
lli.
co
.uk
Page 68 Pirelli Components Unit Commercial Enquiries: tel 0151 430 3655 fax 0151 430 3636
70 35 FMCTs-400/1250-Z 160.94
120 50 FMCTs-400/1250-A 157.68
150 70 FMCTs-400/1250-B 160.94
- 95 FMCTs-400/1250-C 158.40
185 120 FMCTs-400/1250-D 160.94
240 150 FMCTs-400/1250-E 157.68
300 185 FMCTs-400/1250-G 158.40
- 240 FMCTs-400/1250-H 157.68
400 300 FMCTs-400/1250-J 163.52
500 400 FMCTs-400/1250-L 163.52
- 500 FMCTs-400/1250-N 170.23
- 630 FMCTs-400/1250-Q 170.23
Conductor Size
mm2 12kV
Conductor Size
mm2 24kVRef. No.
Price £each
Normal Bushing - 12kV rating 400A in oil FMBOm-400-12 141.46
Normal Bushing - 24kV 400A in oil FMBOm-400-24 141.76
Ref. No.Price £each
Description
DEAD END RECEPTACLEEDPM moulding which provides a dead-end facility for insulating bushings.
Dead End Receptacle 12kV - rating 400A FMR-400-12 79.69
Dead End Receptacle 24kV - rating 400A FMR-400-24 79.69
Description Ref. No.Price £each
TEE CONNECTORTo suit polymeric cable up to 24kV - non-loadbreak operation - 400 series for 630A (with clamping screw).
ACCESSORIES FOR 400A TEE CONNECTORS
CABLE BUSHINGSFor use in oil applications up to 24kV - non-loadbreak operation - rating 400A.
70 - FMCTs-400-Z 134.32
95 - FMCTs-400-A 133.56
120 25 FMCTs-400-B 133.56
150 35 FMCTs-400-C 133.56
185 50 FMCTs-400-D 133.95
240 70 FMCTs-400-E 137.37
300 95 FMCTs-400-F 135.75
- 120/150 FMCTs-400-G 133.56
- 185 FMCTs-400-H 133.95
- 240 FMCTs-400-J 137.37
Conductor Size
mm2 12kV
Conductor Size
mm2 36kVRef. No.
Price £each
TEE CONNECTORTo suit polymeric cable up to 36kV - non-loadbreak operation - 400 series for 630A (with clamping screw).
Voltage Class : kVEarthing Kit : T1 (Polylam) T2 (Copper Tape) T3 (Copper Wire) Conductor Type and size in mm2 : “A” (Aluminium) - mm2 "C" (Copper) - mm2
To select - Ref. no + Voltage class + Earthing kit + Conductor type & size mm2
Note : Typical example for a 12kV tee connector for 95mm2, copper wire screen cable aluminium conductor and socket contact: FMCT-400-A-12-T3-A95.24kV available on request.
Voltage Class : kVEarthing Kit : T1 (Polylam) T2 (Copper Tape) T3 (Copper Wire)Conductor Type and size in mm2: “A” (Aluminium) - mm2 "C" (Copper) - mm2
To select - Ref. no + Voltage class + Earthing kit + Conductor type & size mm2
Note : Typical example for a 24kV tee connector for 300mm2, copper wire screen cable aluminium conductor : FMCTs-400/1250-J-24-T3-A300
28 www.prysmiancable.com.au | www.prysmiancable.co.nz
STRAIGHT CONNECTING PLUG – FMPCs-400
• Epoxy resin moulded over a copper rod. For connection of two tee connectors FMCT-400, FMCTs-400 or FMCTXs-630/C in combinations such as disconnectable joint, tee off or dual cable supply.
• Connection to rod by the clamping screws of the connectors. Integral reconstitution of insulation. Protection through screen continuity of connected items.
• Operated when de-energized.
• Packing: per piece.
ACCESSORIES FOR SERIES 400
SEPARABLE CONNECTORS
SELECTION GUIDE – FMPCs-400
VoltageUm
Reference
Interface C/C Interface B/B Interface B/C
12 kV FMPCs-400-C/C-12 FMPCs-400-B/B-12 FMPCs-400-C/C-12
24 kV FMPCs-400-C/C-24 FMPCs-400-B/B-24 FMPCs-400-C/C-24
36 kV FMPCs-400-C/C-36 – –
FT N
°345
Sep
arab
le S
trai
ght C
onne
ctor
FM
CS 4
00 -
V1 M
ay 2
018
Medium Voltage (MV)Up to 19/33 (36) kVMV Separable Connectors rating 400A (Interface B) Reference: FMCS-400
Separable straight connector FMCS-400(Interface B / 400A) For polymeric cables -Deadbreak - Operation Generally meets the requirement C 33-051 - HD 629.1.S2 - IEC 60502-4 Interface: CENELEC EN50180 - EN50181
Utilisation• For connection of polymeric MV cables to transformers, switchgear units,
motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a
watertight conductive envelope connected to earth. • Continuous 400 A rms overload 600 A rms (8 hours per 24-hour period). • Dead break operation.• Voltage detection through an integrated capacitive voltage
divider.
Cables• Single core polymeric insulation (XLPE). • Copper or aluminum conductor. • Semi-conducting screen either extruded or taped. • Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 36 kV. • Conductor sizes: 25 mm2 to 300) mm2.
Packing Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 4,5 kg / 0,01 m3
Other products• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400A,
interface B.
1/2
Product Application and Design
INTERFACEB / 400 A
®
Prysmian Group Sales department - mail : [email protected]
A mark of
Installation features• No need for special tools, no heating, taping or filling. • Vertical, angled or inverted position. • No minimum distance between phases. • Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end
plug... • Individual clamping by stainless steel brace.• An unplugged connector must never be energized
Description
Accessories for medium voltage separable connectors for series 400, rating 400 A and 630 A. Interfaces B and C.
DEAD-END RECEPTACLE – FMR-400 / FMRs-400
• EPDM moulding with semi-conducting EPDM jacket. Provides a dead-end facility for insulating bushings.
• Operated when de-energized.
• Watertight, slipped on with silicone grease.
• Supplied with locking brace.
• Packing: per piece.
INSULATING PLUG – FMPI-400
• Epoxy resin moulding which provides a dead-end facility for separable tee connectors type FMCT-400 or FMCTs-400.
• Operated when de-energized.
• Includes a capacitive voltage divider that is protected by a cap of semi-conducting EPDM during normal use.
• Packing: per piece.
SELECTION GUIDE – FMR-400 / FMRs-400
VoltageUm
Reference
Interface B Interface C
12 kV FMR-400-12 FMRs-400-12*
24 kV FMR-400-24 FMRs-400-24*
36 kV FMR-400-36 FMRs-400-36*
*Suffix "s" = screw type (for bushings with interface type C).
SELECTION GUIDE – FMPI-400
VoltageUm
Reference
12 kV FMPI-400-12
24 kV FMPI-400-24
36 kV FMPI-400-36
Note! Before using these products, you must check if it is suitable for your intended application. You assume all risks and liability associated with such use. If any doubt, please consult us.
Separable ConnectorsA C C E S S O R I E S F O R 4 0 0 A T E E C O N N E C T O R S
Sec
tion
5 :Sepera
ble
Connecto
rs
All prices are subject to our Terms and Conditions of Sale - see inside front cover for more details Page 69Products with prices in BOLD are made to order and are subject to a minimum order quantity • All other items are normally exstock, subject to remaining unsold. Confirmation will be made at time of order
INSULATING PLUGExpoxy resin mould which provides dead-end facility for separable tee connectors.
Insulating Plug 12kV - rating 400A FMPI-400-12 29.23
Insulating Plug 24kV - rating 400A FMPI-400-24 29.23
Description Ref. No.Price £each
Stand Off Plug 12kV - rating 400A FMPS-400-12 121.60
Stand Off Plug 24kV - rating 400A FMPS-400-24 121.60
Description Ref. No.Price £each
STAND OFF PLUGEDPM moulding which is designed to proivde support and dead-end separable connector when removed from the equipment.
Straight Connection Plug 12kV - rating 400A FMPCs-400-12 141.20
Straight Connection Plug 24kV - rating 400A FMPCs-400-24 141.20
Description Ref. No.Price £each
STRAIGHT CONNECTION PLUGExpoxy resin moulding over a copper rod for connecting two separable tee connectors FMCTs-400.
Earthing Plug - rating 400A FMPE-400 228.33
Description Ref. No.Price £each
EARTHING PLUGEDPM moulding designed to support and earth separable connectors when removed from the equipment.
120 50 FMCTs-600/1250-A 208.92
150 70 FMCTs-600/1250-B 212.18
- 95 FMCTs-600/1250-C 209.64
185 120 FMCTs-600/1250-D 212.18
240 150 FMCTs-600/1250-E 208.92
300 185 FMCTs-600/1250-G 209.64
- 240 FMCTs-600/1250-H 208.92
400 300 FMCTs-600/1250-J 214.76
500 400 FMCTs-600/1250-L 214.76
630 - FMCTs-600/1250-M 221.47
- 500 FMCTs-600/1250-N 222.15
- 630 FMCTs-600/1250-Q 221.47
Conductor Size
mm2 12kV
Conductor Size
mm2 24kVRef. No.
Price £each
SEPARABLE TEE CONNECTORS
TEE CONNECTORTo suit polymeric cables up to 24kV - non-loadbreak operation - rating 1250A (with clamping screw).
Voltage Class : kVEarthing Kit : T1 (Polylam) T2 (Copper Tape) T3 (Copper Wire) Conductor Type and size in mm2 : “A” (Aluminium) - mm2 "C" (Copper) - mm2
To select - Ref. no + Voltage class + Earthing kit + Conductor type & size mm2
Note : Typical example for a 24kV tee connector for 300mm2, copper wirescreen cable aluminium conductor : FMCTs-600/1250-J-24-T3-A300
Separable ConnectorsA C C E S S O R I E S F O R 4 0 0 A T E E C O N N E C T O R S
Sec
tion
5 :Sepera
ble
Connecto
rs
All prices are subject to our Terms and Conditions of Sale - see inside front cover for more details Page 69Products with prices in BOLD are made to order and are subject to a minimum order quantity • All other items are normally exstock, subject to remaining unsold. Confirmation will be made at time of order
INSULATING PLUGExpoxy resin mould which provides dead-end facility for separable tee connectors.
Insulating Plug 12kV - rating 400A FMPI-400-12 29.23
Insulating Plug 24kV - rating 400A FMPI-400-24 29.23
Description Ref. No.Price £each
Stand Off Plug 12kV - rating 400A FMPS-400-12 121.60
Stand Off Plug 24kV - rating 400A FMPS-400-24 121.60
Description Ref. No.Price £each
STAND OFF PLUGEDPM moulding which is designed to proivde support and dead-end separable connector when removed from the equipment.
Straight Connection Plug 12kV - rating 400A FMPCs-400-12 141.20
Straight Connection Plug 24kV - rating 400A FMPCs-400-24 141.20
Description Ref. No.Price £each
STRAIGHT CONNECTION PLUGExpoxy resin moulding over a copper rod for connecting two separable tee connectors FMCTs-400.
Earthing Plug - rating 400A FMPE-400 228.33
Description Ref. No.Price £each
EARTHING PLUGEDPM moulding designed to support and earth separable connectors when removed from the equipment.
120 50 FMCTs-600/1250-A 208.92
150 70 FMCTs-600/1250-B 212.18
- 95 FMCTs-600/1250-C 209.64
185 120 FMCTs-600/1250-D 212.18
240 150 FMCTs-600/1250-E 208.92
300 185 FMCTs-600/1250-G 209.64
- 240 FMCTs-600/1250-H 208.92
400 300 FMCTs-600/1250-J 214.76
500 400 FMCTs-600/1250-L 214.76
630 - FMCTs-600/1250-M 221.47
- 500 FMCTs-600/1250-N 222.15
- 630 FMCTs-600/1250-Q 221.47
Conductor Size
mm2 12kV
Conductor Size
mm2 24kVRef. No.
Price £each
SEPARABLE TEE CONNECTORS
TEE CONNECTORTo suit polymeric cables up to 24kV - non-loadbreak operation - rating 1250A (with clamping screw).
Voltage Class : kVEarthing Kit : T1 (Polylam) T2 (Copper Tape) T3 (Copper Wire) Conductor Type and size in mm2 : “A” (Aluminium) - mm2 "C" (Copper) - mm2
To select - Ref. no + Voltage class + Earthing kit + Conductor type & size mm2
Note : Typical example for a 24kV tee connector for 300mm2, copper wirescreen cable aluminium conductor : FMCTs-600/1250-J-24-T3-A300
29www.prysmiancable.com.au | www.prysmiancable.co.nz
STAND-OFF PLUG – FMPS-400 / FMPSs-400
• EPDM moulding designed to support and dead-end separable connectors when removed from the equipment.
• The stand-off plug is equipped with a metallic bracket. The part in semi-conducting EPDM provides the electrical continuity with the outer envelope of the separable connector.
• Operated when de-energized.
• Packing: per piece.
EARTHING PLUG – FMPE-400 / FMPEs-400
• EPDM moulding designed to support and earth separable connectors when removed from the equipment
• The earthing-plug is equipped with a metallic bracket.
• Packing: per piece.
SEPARABLE CONNECTORS
SELECTION GUIDE – FMPS-400 / FMPSs-400
VoltageUm
Reference
Interface B Interface C
12 kV FMPS-400-12 FMPSs-400-12*
24 kV FMPS-400-24 FMPSs-400-24*
36 kV FMPS-400-36 FMPSs-400-36*
*Suffix "s" = screw type (for interface type C).
SELECTION GUIDE – FMPE-400 / FMPEs-400
Reference
Interface B Interface C
FMPE-400 FMPEs-400*
*Suffix "s" = screw type (for interface type C).
FT N
°345
Sep
arab
le S
trai
ght C
onne
ctor
FM
CS 4
00 -
V1 M
ay 2
018
Medium Voltage (MV)Up to 19/33 (36) kVMV Separable Connectors rating 400A (Interface B) Reference: FMCS-400
Separable straight connector FMCS-400(Interface B / 400A) For polymeric cables -Deadbreak - Operation Generally meets the requirement C 33-051 - HD 629.1.S2 - IEC 60502-4 Interface: CENELEC EN50180 - EN50181
Utilisation• For connection of polymeric MV cables to transformers, switchgear units,
motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a
watertight conductive envelope connected to earth. • Continuous 400 A rms overload 600 A rms (8 hours per 24-hour period). • Dead break operation.• Voltage detection through an integrated capacitive voltage
divider.
Cables• Single core polymeric insulation (XLPE). • Copper or aluminum conductor. • Semi-conducting screen either extruded or taped. • Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 36 kV. • Conductor sizes: 25 mm2 to 300) mm2.
Packing Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 4,5 kg / 0,01 m3
Other products• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400A,
interface B.
1/2
Product Application and Design
INTERFACEB / 400 A
®
Prysmian Group Sales department - mail : [email protected]
A mark of
Installation features• No need for special tools, no heating, taping or filling. • Vertical, angled or inverted position. • No minimum distance between phases. • Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end
plug... • Individual clamping by stainless steel brace.• An unplugged connector must never be energized
TEST ROD – FMTR-400
• For testing or earthing of cables equipped with separable tee connectors.
• Screwed onto threaded part of contact pin or on clamping screw of tee connectors.
• Packing: per piece.
SELECTION GUIDE – FMTR-400
VoltageUm
Reference
12 and 24 kV FMTR-400
30 www.prysmiancable.com.au | www.prysmiancable.co.nz
INTERFACE FOR SEPARABLE CONNECTORS
According to CENELEC EN 50180 & EN 50181 Prysmian specific
Type: A B2 C1 D1 / D2 E1 / E2 Z
Drawings:
A mark of
FT N
°334
Inte
rfac
es fo
r sep
arab
le c
onne
ctor
s -
May
201
8
Medium Voltage (MV)Up to 36 kV
R E A C H
Interfaces for separable connectors
1/1
According CENELEC* EN 50180 et EN 50181
Type A B2 C1 D1/D2 E1/E2Z
(Propre à PRYSMIAN)
Drawings
Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1Bore
Ø 7,9 mm, Depth:32 mm
BoreØ 14 mm,
Depth: 40 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm
D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm
D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm
Utilisation250 ASliding contact12 & 24 kV
400 ASliding contact12,24&36kV
630 ABolted contact12,24 & 36 kV
1250 ABolted contact12 & 24 kV
1250 ABolted contact36 kV
630 ABolted contact12,24 & 36 kVSpecial interface
Remarks Same dimensions as interface C
Same dimen-sions as Inter-face B
N.A in Prysmian product range
Profile identical to the interface C, but shortened (the angle is the same)
* Except for Interface Z which is a Prysmian specific size
Prysmian Group Sales department - mail : [email protected]
© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
A mark of
FT N
°334
Inte
rfac
es fo
r sep
arab
le c
onne
ctor
s -
May
201
8
Medium Voltage (MV)Up to 36 kV
R E A C H
Interfaces for separable connectors
1/1
According CENELEC* EN 50180 et EN 50181
Type A B2 C1 D1/D2 E1/E2Z
(Propre à PRYSMIAN)
Drawings
Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1Bore
Ø 7,9 mm, Depth:32 mm
BoreØ 14 mm,
Depth: 40 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm
D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm
D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm
Utilisation250 ASliding contact12 & 24 kV
400 ASliding contact12,24&36kV
630 ABolted contact12,24 & 36 kV
1250 ABolted contact12 & 24 kV
1250 ABolted contact36 kV
630 ABolted contact12,24 & 36 kVSpecial interface
Remarks Same dimensions as interface C
Same dimen-sions as Inter-face B
N.A in Prysmian product range
Profile identical to the interface C, but shortened (the angle is the same)
* Except for Interface Z which is a Prysmian specific size
Prysmian Group Sales department - mail : [email protected]
© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
A mark of
FT N
°334
Inte
rfac
es fo
r sep
arab
le c
onne
ctor
s -
May
201
8
Medium Voltage (MV)Up to 36 kV
R E A C H
Interfaces for separable connectors
1/1
According CENELEC* EN 50180 et EN 50181
Type A B2 C1 D1/D2 E1/E2Z
(Propre à PRYSMIAN)
Drawings
Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1Bore
Ø 7,9 mm, Depth:32 mm
BoreØ 14 mm,
Depth: 40 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm
D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm
D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm
Utilisation250 ASliding contact12 & 24 kV
400 ASliding contact12,24&36kV
630 ABolted contact12,24 & 36 kV
1250 ABolted contact12 & 24 kV
1250 ABolted contact36 kV
630 ABolted contact12,24 & 36 kVSpecial interface
Remarks Same dimensions as interface C
Same dimen-sions as Inter-face B
N.A in Prysmian product range
Profile identical to the interface C, but shortened (the angle is the same)
* Except for Interface Z which is a Prysmian specific size
Prysmian Group Sales department - mail : [email protected]
© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
A mark of
FT N
°334
Inte
rfac
es fo
r sep
arab
le c
onne
ctor
s -
May
201
8
Medium Voltage (MV)Up to 36 kV
R E A C H
Interfaces for separable connectors
1/1
According CENELEC* EN 50180 et EN 50181
Type A B2 C1 D1/D2 E1/E2Z
(Propre à PRYSMIAN)
Drawings
Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1Bore
Ø 7,9 mm, Depth:32 mm
BoreØ 14 mm,
Depth: 40 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm
D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm
D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm
Utilisation250 ASliding contact12 & 24 kV
400 ASliding contact12,24&36kV
630 ABolted contact12,24 & 36 kV
1250 ABolted contact12 & 24 kV
1250 ABolted contact36 kV
630 ABolted contact12,24 & 36 kVSpecial interface
Remarks Same dimensions as interface C
Same dimen-sions as Inter-face B
N.A in Prysmian product range
Profile identical to the interface C, but shortened (the angle is the same)
* Except for Interface Z which is a Prysmian specific size
Prysmian Group Sales department - mail : [email protected]
© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
A mark of
FT N
°334
Inte
rfac
es fo
r sep
arab
le c
onne
ctor
s -
May
201
8
Medium Voltage (MV)Up to 36 kV
R E A C H
Interfaces for separable connectors
1/1
According CENELEC* EN 50180 et EN 50181
Type A B2 C1 D1/D2 E1/E2Z
(Propre à PRYSMIAN)
Drawings
Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1Bore
Ø 7,9 mm, Depth:32 mm
BoreØ 14 mm,
Depth: 40 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm
D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm
D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm
Utilisation250 ASliding contact12 & 24 kV
400 ASliding contact12,24&36kV
630 ABolted contact12,24 & 36 kV
1250 ABolted contact12 & 24 kV
1250 ABolted contact36 kV
630 ABolted contact12,24 & 36 kVSpecial interface
Remarks Same dimensions as interface C
Same dimen-sions as Inter-face B
N.A in Prysmian product range
Profile identical to the interface C, but shortened (the angle is the same)
* Except for Interface Z which is a Prysmian specific size
Prysmian Group Sales department - mail : [email protected]
© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
A mark of
FT N
°334
Inte
rfac
es fo
r sep
arab
le c
onne
ctor
s -
May
201
8
Medium Voltage (MV)Up to 36 kV
R E A C H
Interfaces for separable connectors
1/1
According CENELEC* EN 50180 et EN 50181
Type A B2 C1 D1/D2 E1/E2Z
(Propre à PRYSMIAN)
Drawings
Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1Bore
Ø 7,9 mm, Depth:32 mm
BoreØ 14 mm,
Depth: 40 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
Thread M16, Depth: 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm
D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm
D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm
Utilisation250 ASliding contact12 & 24 kV
400 ASliding contact12,24&36kV
630 ABolted contact12,24 & 36 kV
1250 ABolted contact12 & 24 kV
1250 ABolted contact36 kV
630 ABolted contact12,24 & 36 kVSpecial interface
Remarks Same dimensions as interface C
Same dimen-sions as Inter-face B
N.A in Prysmian product range
Profile identical to the interface C, but shortened (the angle is the same)
* Except for Interface Z which is a Prysmian specific size
Prysmian Group Sales department - mail : [email protected]
© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
Insulator voltage: 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV
Continuous current: 250 A 400 A 630 A 1 250 A 1 250 A 630 A
D1 Bore: Ø 7.9 mm, depth 32 mm
Bore: Ø 14 mm, depth 40 mm
Thread: M16, depth 29 mm
Thread: M16, depth 29 mm
Thread: M16, depth 29 mm
Thread: M16, depth 29 mm
D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39.9 mm Ø 39.9 mm Ø 49.9 mm
D3 Ø 32.5 mm Ø 56 mm Ø 56 mm Ø 52.1 mm Ø 61.5 mm Ø 56 mm
D4 Ø 48.5 mm Ø 70 mm Ø 70 mm Ø 76.2 mm Ø 76.2 mm Ø 70 mm
L1 48 mm 90 mm 90 mm 81 mm 103.7 mm 55 mm
Utilisation:250 A Sliding contact 12 & 24 kV
400 A Sliding contact 12, 24 & 36 kV
630 A Bolted contact 12, 24 & 36 kV
1 250 A Bolted contact 12 & 24 kV
1 250 A Bolted contact 36 kV
630 A Bolted contact 12, 24 & 36 kV Special interface
Remarks: –Same dimensions as interface C.
Same dimensions as Interface B.
– N.A in Prysmianproduct range.
Profile identical to the interface C, but shortened (the angle is the same).
Description
Interfaces for separable connectors. Medium voltage (MV). Up to 36 kV.
INTERFACES
SEPARABLE CONNECTORS
31www.prysmiancable.com.au | www.prysmiancable.co.nz
© A
ll rights reserved by Prysmian Group 20
18-11 | V.2
Prysmian Australia Pty Ltd
1 Heathcote Road, Liverpool 2170 NSW, Australia Ph: 1300 300 304 Fx: 1300 300 307 E-mail: [email protected] www.prysmiancable.com.au
Prysmian New Zealand Ltd
30 Binsted Road, New Lynn 0600 Auckland, New Zealand Ph: (09) 827 3109 Toll Free: 0800 492 225 E-mail: [email protected] www.prysmiancable.co.nz
Connect with us
Prysmian Australia & New Zealand
Prysmian Group
Linking the future