Page 3: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

The Problem

Looks familiar ??

•Mud•Art scale•Bio-organic matters•Sea shells•Odd particles

Page 4: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

ATCS is a patented system based on the concept of using sponge balls that are injected into the cooling unit without interfering with its operation.

C.Q.M Solution

Page 5: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M Solution

C.Q.M-demo

Page 6: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M Solution

Page 7: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

Ball Traps

Two Types of Ball Traps

InlineAngular

Page 8: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

System Position

Injection point as close as possible to the collector

Ball trap installed in a way to allow removal of the screen for maintenance

Page 9: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M Solution

Before start-up – check that heat exchanger is clean.

C.Q.M ensures that it remains clean forever.

Page 10: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M Applications

Buildings with cooling towers.

Heavy industries. Power plants. Food industries. Other industries.

Page 11: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M Applications Buildings with cooling

towers. Heavy industry. Power plan. Food industries. Other industries.

• Hospitals. • Office towers.• Hotels.• ETC….

Page 12: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M Applications Buildings with cooling

towers. Heavy industry. Power plan. Food industries. Other industries.

• Client: Swire• Project name: Taikoo• Installed one system for trail period• Order an research from HK University.• Research conclusion.

Order of 11 CQM sets for the entire buildings.

Page 13: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M Applications Buildings with cooling towers. Heavy industry. Power plants. Food industries.

Other industries.

Order of 11 C.Q.M sets for the entire buildings.

Page 14: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M Applications Buildings with cooling

towers. Heavy industry. Power plants. Food industries. Other industries.

• Refiner.• Petrochemicals factory.• ETC….

Page 15: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M ApplicationsBuildings with cooling

towers.Heavy industry.Power plants.Food industries.Other industries.

RefinerPetrochemicals factoryETC….

Page 16: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M Applications Buildings with cooling

towers. Heavy industry. Power plants Food industries. Other industries.

• Sea water or cooling towers.

• Coal. • Gas. • Fuels. • Combine cycles.

Page 17: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M Applications Buildings with cooling

towers. Heavy industry. Power plants Food industries. Other industries. .

• Sea water or cooling towers.

• Coral. • Gas. • Fuels. • Combine cycles.

Page 18: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M Applications Buildings with cooling

towers. Heavy industry. Power plants. Food industries. Other industries.

• Juice industries• Milk dairy• Coffee• Beer• Deep freeze• Sultry houses

Page 19: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M Applications Buildings with cooling

towers. Heavy industry. Power plants. Food industries. Other industries.

• Textile factories• Paper factory• Semi conductors

industries

Page 20: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

Green Label – Environment FriendlyGreen Label – Environment Friendly

Page 21: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

ISO ISO 9002 9002

Page 22: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

C.Q.M C.Q.M AAutomatic utomatic TTube ube CCleaning leaning SSystemystem

Tube cross section

Scale thickness fouling factor(ff)

0.000” clean tube0.006” 0.00050.012” 0.0010.024” 0.0020.036” 0.003

110100

150140130120

0.001 0.002 0.003 ff

Relative horse power %

Page 23: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

When the condenser is clean we get:

Vacuum stability

Stable product temperature

Eliminate the burning of the production

Juice factory

Evaporator condenser in food industry

Page 24: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

Tenuva factory in Israel

During the production of milk powder in the past, there was a need to clean the condenser monthly.

After C.Q.M installation in 1996, the condenser kept clean and production capacity improved.

Evaporator condenser in dairy factory

Page 25: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

Oil factory in Turkey

Producing Soya and sun flower oil

Most of the oil factories worldwide are using the C.Q.M system due to a special method that improve the production and capacity of the oil.

Evaporator condenser in oil factory

Page 26: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

Nestle Coffee factory – Portugal

This application is using a river water, which have a mud and dirt, the condenser use to be cleaned every two weeks. C.Q.M systems were installed in 1999, since then the evaporator condenser kept 100% clean, resulting in higher production.

Evaporator condenser in Nestle Coffee factory

Page 27: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

Great energy savings in addition to elimination of maintenance costs.

Chemicals industries

Heavy industries

Page 28: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

Samsung factories

Over 100 system installed in Samsung factories worldwide, many of them in Korea and China

Chemicals industries

Heavy industries

Page 29: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

Bromine Industries

The main problem in the Bromine industries is the dust that enters the cooling towers and receptacle in the condenser tubes

25 CQM systems were installed in 1997 saving USD 200,000.00 per year.

During the years the factory purchased additional systems, today there have more than 35 systems in stalled.

Chemicals industries

Heavy industries

Page 30: C.Q.M Automatic T ube C leanin g S ystem (ATCS) June-2005.

Chemicals industries

Heavy industries

Chemagis factory

This factory tried several method to treat the water in the condenser, but all were failed.

C.Q.M installed a system for trail period, after 3-months the client open the condenser for inspection, and upon the excellent results they purchase more systems.

Before C.Q.M installation

After 1 year