    SCOPE Introduction

    Current requirements

    Changes

    Conclusion

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    3/38

    Introduction

    Presentation will be in 2 parts: Skygarden then hotel

    Terminology - Hotel and sky garden

    OL refers to Occupant Load

    Background of the review

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    4/38

    - Sky garden based on 1.5 m2/ person

    - QP needs to apply waiver to use higher

    occupancy load factors

    Current Requirements (Sky Garden)

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    5/38

    Types of structure at sky garden- Landscape

    floor level landscape (with or without fencing)

    raised landscape landscape with pebbles/stones

    - Decorative features, eg statute/fountain

    If roof top only

    for

    maintenance

    purpose thenneed not

    calculate OL

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    6/38

    -Shallow pool / small drain / water features

    -Tables/chairs

    -Raised platform as seat

    -playground/gym

    -Jogging track

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    7/38

    Type of use No Yes Remark

    Purpose I Private roof

    garden/terraceof residential

    unit

    Purpose II Roof garden /terrace belong

    to a residential

    unit

    Common skygarden/roof

    terrace

    accessible to

    residents &

    guests

    OL factorto base on

    1.5 m2/

    person

    Calculation of Occupant Load

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    8/38

    Type of use No Yes Remark

    Purpose

    III - VIII

    Roof access

    for

    maintenance

    only

    Roof garden/roof

    terrace

    accessible to

    other members of

    public or to staff inthe building.

    Occupant

    load factor

    to base on

    1.5

    m2/person

    Calculation of Occupant Load

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    9/38

    Planter boxes used for reducingOL calculation

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    10/38

    Depth of planter box below

    finished floor level

    Occupant load

    factor

    < 300mm To base on 1.5 m2/

    person

    < 300 < 500mm (with full ofshrubs and trees)

    Need not calculate OL

    < 300 < 500mm (without full of

    shrubs and trees)

    To base on 3.0 m2/

    person

    Ht < 500mm (need not be

    covered with trees/shrubs but

    must be without access)

    Do not need to

    calculate occupant

    load

    Sunken Planter Box

    (Permanent / fixed structure)

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    11/38

    Depth of planter box

    below finished floor level

    Occupant load

    factor

    < 300mm To base on 1.5 m2/

    person

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    12/38

    Habitable

    Planter box not covered with trees/shrubs

    Depth of planter box

    below finished floor level

    Occupant load

    factor

    < 300 < 500mm (with full of

    shrubs and trees)

    Need not calculate

    OL

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    13/38

    Depth of planter box

    below finished floor level

    Occupant load

    factor

    > 500mm (with or withoutshrubs and Trees

    Need not calculateOL

    > 500mm high

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    14/38

    Height of planter box

    above floor finished level

    Occupant load

    factor

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    15/38

    Height of planter boxabove floor finished level

    Occupant loadfactor

    300 mm < Ht < 500mm

    (planter box not coveredwith trees/shrubs)

    To base on 1.5 m2/

    person

    Planter Box (Permanent/fixed structure)

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    16/38

    Height of planter box

    above floor finished level

    Occupant load

    factor

    Ht > 500mm (need not be

    covered with trees/shrubs

    but must be withoutaccess)

    Do not need to

    calculate occupant

    load

    Planter Box (Permanent/fixed structure)

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    17/38

    Not habitable

    Raised planting bed with trees or shrubs between

    300mm and 500mm and width of planter box not

    exceeding 3m

    300mm

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    18/38

    >500

    Raised Planter box above 500mm-must be without steps

    Note: Roof level without public access (for

    maintenance only) can be exempted from occupant

    load calculation

    Walkway

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    19/38

    Unacceptable features to be considered as

    Non-simultaneous Occupancy

    Using cabinet or Movable container

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    20/38

    Depth/height of water

    feature

    Occupant load factor

    Less than 300mm To base on 3 m2/ person

    Depth > 300mm Do not need to calculate

    occupant load

    Sunken/Elevated Water Feature

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    21/38

    Pond - Need not calculate

    OL

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    22/38

    300mm

    The surface area need to

    allocate 3 m2/ person if any

    depth exceeded 300mm

    deep

    Cross section of pool

    Walk way

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    23/38

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    24/38

    Water

    features

    APPLY 3 m2/ person

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    25/38

    Jogging Track / foot path

    (width

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    26/38

    < 3 m wide 3m 2/person,

    otherwise 1.5m2/person

    Playground

    5m2/person

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    27/38

    5m

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    28/38

    1.5 m2/

    person

    Running track

    Running track

    Open space

    3 m2/ person

    3 m2/ person

    Playground

    5m2/

    person

    3m

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    29/38

    Note: QP is to submit plan

    for approval if there is A/Aworks to the roof

    terrace/roof garden orwhen it is affecting OL

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    30/38

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    31/38

    Background

    Current Requirements 4 to a room

    Service apartment: 15 m2/person

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    32/38

    a. Hotel/Budget Hotel

    - Bedroom: will base on 15 m2/ person

    (based on gross area of a room)

    - Suite: to base on 15 m2/ person a room(i.e. include all areas such as living area,

    toilets, etc)

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    33/38

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    34/38

    b. Backpacker hotel where room(s) are shared

    by guests:

    - To base on 3 m2/ person, subject to

    max 20 pax per room (i.e. area of 60 m2)

    - To base on the gross area of the unit

    (i.e. includes toilets, living room,

    etc)

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    35/38

    For circular on Hotel and skygarden you may refer to

    CORENET FSSD circular

    dated 2 June 2011 and 1

    August 2011, respectively.

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    36/38

    Conclusion

    We will continue to listen to thefeedback from the industry and fine

    tune our fire safety requirements to

    achieve a safe and secure

    Singapore.

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    37/38

    Thank you

  • 7/27/2019 Cpt Yam OL for Hotel Roof Gdn Roof Terrace Sky Terrace

    38/38

    Question asked during seminar

    My hotel needsd FC every year because it exceeded 200 persons. If I

    apply the new calculation then I need not apply FC anymore, how

    should I go about in getting exemption?

    There is no exemption unless a plan submission is resubmitted and

    the building has to comply with the current requirement. The

    calculation shall be basing on each room not basing on the whole floorarea i.e. refers to slide 33 showing the hotel flr plan, each room shall

    have the its respective area to divide by the OL factor, this includes all

    usage like toilet, and with any decimal place it shall be brought forward

    to the next nearest number, from there sum up every individual room

    to obtain the total floor OL. Also, pls note that a minimum of 2 personsper room shall apply if the OL for each room is less than 2.