Single Conductor Power/Distribution Cable Type P, 2000 volts DRILMAR™ 125-XE Crosslinked Polyolefin Insulated/CP Jacket Drilling Rig and Marine Cable 1600 Distribution Dr., Duluth, GA 30097 Tel: 770-623-0001 Fax: 770-623-5789 e-mail: [email protected] website: www.cmewire.com Features Engineered for easiest installation. Extra flexible stranding meets IEEE, UL, and CSA requirements. Maximum conductor operating temperature: 100°C as Type P per IEEE, and 110°C as Type X110 per UL and CSA. Meets ampacity ratings per ABS, DNV, LRS, and TCMS. DRILMAR XLPO Insulation Superior oil and chemical resistance Sunlight resistant Rated at 125ºC Passes Cold Bend at -55ºC Heavy Duty CP Jacket Arctic Type XE design Abrasion and sunlight resistant Rated at 90ºC Completed cable offers superior flame resistance meeting: 70,000 BTU Flame Tests IEEE 1202/FT4, IEEE 383, UL 1685, ICEA T-30-820, and IEC 332 Category A. 210,000 BTU Flame Test ICEA T-29-520. Arctic Type design meets Cold Bend and Impact Tests at -40ºC, exceeding the Transport Canada Marine Safety requirements. Cables meet applicable requirements of IEC 92-350. Application DRILMAR 125-XE cables are specifically designed for the installation and use in marine environments, for use on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. These cables are used for the distribution of power in circuits rated for 2000 volts. Typical applications include: D/C motor cables, generators, transformers, top drives, and other applications that may require a highly flexible rugged power cable. Standards IEEE 1580-2001: Recommended Practice for Marine Cable for Use on Shipboard and Fixed and Floating Platforms UL 1309-1995: Marine Shipboard Cable CSA C22.2 No. 245: Marine Shipboard Cable Approvals UL and CSA, as Type P UL and CSA, as Type X110 ABS, American Bureau of Shipping DNV, Det Norske Veritas LRS, Lloyd’s Register of Shipping United States Coast Guard TCMS, Transport Canada Marine Safety Engineering Information Unarmored Design Conductor: Soft annealed flexible Tin Coated Copper per IEEE, UL, and CSA. Sizes: 14 AWG up to 1111 kcmil. Separator Tape: Polyester tape as required. Insulation: Flame retardant and sunlight resistant Crosslinked Polyolefin (XLPO) per IEEE. Also meets and exceeds the requirements of UL and CSA for Type X110. DRILMAR 125-XE is a 125°C XLPO. CP Jacket: Flame retardant and sunlight resistant Arctic Type Chlorosulfonated Polyethylene (CP) per IEEE, UL, and CSA. Armored Design Unarmored Design (see above description) Plus: Armor: Standard - Bronze. Optional - Aluminum or Tinned Copper Braid per IEEE, UL, and CSA. Armored and Sheathed Design Armored Design (see above description) Plus: CP Jacket (Overall): Flame retardant and sunlight resistant Arctic Type Chlorosulfonated Polyethylene (CP) per IEEE, UL, and CSA. CP Jacket (overall optional) CP Jacket Armor (optional) XLPO Polyolefin Insulation Flexible Tin Coated Copper Stranded Conductor Page 1.9

Transcript of CP Jacket Single Conductor Power/Distribution Cable · IEEE 1202/FT4, IEEE 383, ... Single...

Page 1: CP Jacket Single Conductor Power/Distribution Cable · IEEE 1202/FT4, IEEE 383, ... Single Conductor Power/Distribution Cable Type P, 600/1000/2000 volts ... 100ºC &110ºC Based

Single ConductorPower/Distribution CableType P, 2000 volts DRILMAR™ 125-XECrosslinked Polyolefin Insulated/CPJacketDrilling Rig and Marine Cable

1600 Distribution Dr., Duluth, GA 30097 Tel: 770-623-0001 Fax: 770-623-5789e-mail: [email protected] website: www.cmewire.com

Features

• Engineered for easiestinstallation. Extra flexiblestranding meets IEEE, UL, and CSA requirements.

• Maximum conductoroperating temperature: 100°C as Type P per IEEE, and 110°C as Type X110per UL and CSA. Meets ampacity ratings per ABS, DNV, LRS, and TCMS.

• DRILMAR XLPO Insulation• Superior oil and

chemical resistance• Sunlight resistant• Rated at 125ºC• Passes Cold Bend at -55ºC

• Heavy Duty CP Jacket• Arctic Type XE design• Abrasion and

sunlight resistant• Rated at 90ºC

• Completed cable offers superior flame resistance meeting: • 70,000 BTU Flame Tests

IEEE 1202/FT4, IEEE 383,UL 1685, ICEA T-30-820, and IEC 332 Category A.

• 210,000 BTU Flame TestICEA T-29-520.

• Arctic Type design meetsCold Bend and Impact Tests at -40ºC, exceeding theTransport Canada MarineSafety requirements.

• Cables meet applicablerequirements of IEC 92-350.

Application

DRILMAR 125-XE cables are specifically designed for the installation and use in marine environments, for use on offshoredrilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Thesecables are used for the distribution of power in circuits rated for 2000 volts.

Typical applications include: D/C motor cables, generators, transformers, top drives, and otherapplications that may require a highly flexible rugged power cable.

Standards

IEEE 1580-2001: RecommendedPractice for Marine Cable for Use on Shipboard and Fixed andFloating Platforms

UL 1309-1995: Marine Shipboard Cable

CSA C22.2 No. 245: MarineShipboard Cable

Approvals

� UL and CSA, as Type P

� UL and CSA, as Type X110

� ABS, American Bureau of Shipping

� DNV, Det Norske Veritas

� LRS, Lloyd’s Register of Shipping

� United States Coast Guard

� TCMS, Transport Canada Marine Safety

Engineering Information

Unarmored DesignConductor: Soft annealed flexibleTin Coated Copper per IEEE, UL, and CSA. Sizes: 14 AWG up to 1111 kcmil.

Separator Tape: Polyester tapeas required.

Insulation: Flame retardant and sunlight resistant CrosslinkedPolyolefin (XLPO) per IEEE. Also meets and exceeds the requirements of UL and CSA for Type X110. DRILMAR 125-XE is a 125°C XLPO.

CP Jacket: Flame retardant and sunlight resistant Arctic TypeChlorosulfonated Polyethylene (CP)per IEEE, UL, and CSA.

Armored DesignUnarmored Design (see above description)Plus:Armor: Standard - Bronze. Optional - Aluminum or Tinned Copper Braid per IEEE, UL, and CSA.

Armored and Sheathed DesignArmored Design (see above description)Plus:CP Jacket (Overall): Flame retardantand sunlight resistant Arctic TypeChlorosulfonated Polyethylene (CP)per IEEE, UL, and CSA.

CP Jacket(overall optional)

CP JacketArmor(optional)

XLPO PolyolefinInsulation

Flexible Tin CoatedCopper Stranded Conductor

Page1.9

Page 2: CP Jacket Single Conductor Power/Distribution Cable · IEEE 1202/FT4, IEEE 383, ... Single Conductor Power/Distribution Cable Type P, 600/1000/2000 volts ... 100ºC &110ºC Based

Single ConductorPower/Distribution CableType P, 2000 volts DRILMAR™ 125-XECrosslinked Polyolefin Insulated/CPJacketDrilling Rig and Marine Cable

1600 Distribution Dr., Duluth, GA 30097 Tel: 770-623-0001 Fax: 770-623-5789e-mail: [email protected] website: www.cmewire.com

Catalog Code DSPCP

*To build a CME Part Number, simply add the appropriate Suffix after the Catalog Code listed at the top of the page.

14 19 4-1 0.25 6.5 44 66 0.31 7.8 A4-1 60 89 T4-1 93 138 B4-1 92 13612 19 6-1 0.27 6.9 55 82 0.33 8.3 A6-1 72 107 T6-1 107 160 B6-1 106 15810 27 10-1 0.31 7.7 75 112 0.36 9.1 A10-1 94 139 T10-1 133 198 B10-1 131 1958 37 16-1 0.35 8.8 99 147 0.40 10.2 A16-1 119 178 T16-1 164 243 B16-1 162 2416 63 26-1 0.40 10.3 146 217 0.46 11.7 A26-1 170 252 T26-1 221 328 B26-1 218 3254 105 41-1 0.46 11.7 212 316 0.52 13.1 A41-1 239 356 T41-1 297 442 B41-1 295 4382 154 66-1 0.55 13.9 304 453 0.60 15.3 A66-1 336 500 T66-1 404 601 B66-1 401 5961 224 83-1 0.63 16.0 423 630 0.69 17.4 A83-1 459 683 T83-1 537 799 B83-1 534 794

1/0 273 105-1 0.67 17.0 497 739 0.73 18.4 A105-1 535 796 T105-1 617 918 B105-1 614 9132/0 323 133-1 0.73 18.4 580 863 0.78 19.8 A133-1 621 924 T133-1 710 1056 B133-1 706 10503/0 456 167-1 0.81 20.7 776 1155 0.87 22.0 A167-1 822 1224 T167-1 921 1371 B167-1 917 13654/0 551 211-1 0.91 23.1 952 1417 0.96 24.5 A211-1 1003 1493 T211-1 1114 1657 B211-1 1109 1650

262.6 646 262-1 0.98 24.9 1112 1654 1.03 26.3 A262-1 1167 1736 T262-1 1285 1913 B262-1 1280 1905313.1 779 313-1 1.04 26.5 1306 1944 1.10 27.9 A313-1 1365 2031 T313-1 1491 2219 B313-1 1486 2211373.7 925 373-1 1.11 28.2 1518 2259 1.17 29.6 A373-1 1580 2351 T373-1 1714 2551 B373-1 1708 2542444.4 1110 444-1 1.19 30.1 1783 2654 1.24 31.5 A444-1 1850 2753 T444-1 1993 2966 B444-1 1987 2957535.3 1332 535-1 1.30 33.0 2140 3184 1.35 34.4 A535-1 2212 3292 T535-1 2369 3525 B535-1 2362 3515646.4 1591 646-1 1.39 35.2 2508 3733 1.44 36.6 A646-1 2586 3848 T646-1 2753 4096 B646-1 2745 4085777.7 1924 777-1 1.49 37.9 2979 4433 1.55 39.3 A777-1 3062 4557 T777-1 3241 4823 B777-1 3233 48121111.1 2745 1111-1 1.81 46.1 4313 6418 1.87 47.5 A1111-1 4414 6569 T1111-1 4631 6891 B1111-1 4621 6877

suffix inches mm lbs/mft kg/km inches mm suffix lbs/mft kg/km suffix lbs/mft kg/km suffix lbs/mft kg/km

Aluminum Tin Copper Bronze

Conductor Unarmored Armored

inches mm suffix lbs/mft kg/km suffix lbs/mft kg/km suffix lbs/mft kg/km

Aluminum Tin Copper Bronze

Armored and SheathedConductor

DATA PROVIDED IS SUBJECT TO MANUFACTURING TOLERANCES.

Part No.* Nominal OD Net Weight Nominal OD Part No.* Net Weight Part No.* Net Weight Part No.* Net Weight

10Nominal OD Part No.* Net Weight Part No.* Net Weight Part No.* Net Weight

StrandCount

SizeAWG/kcmil

StrandCount

SizeAWG/kcmil

14 19 0.40 10.3 AS4-1 96 143 TS4-1 130 193 BS4-1 128 19112 19 0.42 10.7 AS6-1 111 165 TS6-1 146 218 BS6-1 145 21510 27 0.46 11.6 AS10-1 136 202 TS10-1 175 260 BS10-1 173 2588 37 0.50 12.6 AS16-1 166 247 TS16-1 210 312 BS16-1 208 3096 63 0.58 14.8 AS26-1 240 358 TS26-1 291 434 BS26-1 289 4304 105 0.64 16.3 AS41-1 318 473 TS41-1 376 559 BS41-1 373 5562 154 0.73 18.5 AS66-1 426 634 TS66-1 494 735 BS66-1 491 7311 224 0.81 20.6 AS83-1 561 835 TS83-1 639 950 BS83-1 635 945

1/0 273 0.89 22.6 AS105-1 680 1012 TS105-1 762 1134 BS105-1 758 11292/0 323 0.95 24.0 AS133-1 776 1154 TS133-1 865 1287 BS133-1 861 12813/0 456 1.03 26.2 AS167-1 993 1478 TS167-1 1092 1625 BS167-1 1088 16194/0 551 1.13 28.7 AS211-1 1191 1772 TS211-1 1301 1936 BS211-1 1296 1929

262.6 646 1.20 30.5 AS262-1 1367 2034 TS262-1 1486 2211 BS262-1 1481 2203313.1 779 1.26 32.1 AS313-1 1577 2346 TS313-1 1703 2534 BS313-1 1698 2526373.7 925 1.33 33.8 AS373-1 1804 2685 TS373-1 1938 2884 BS373-1 1932 2875444.4 1110 1.41 35.7 AS444-1 2087 3106 TS444-1 2230 3319 BS444-1 2224 3310535.3 1332 1.52 38.6 AS535-1 2470 3676 TS535-1 2626 3908 BS535-1 2620 3898646.4 1591 1.61 40.8 AS646-1 2859 4255 TS646-1 3026 4503 BS646-1 3019 4492777.7 1924 1.77 45.0 AS777-1 3468 5162 TS777-1 3647 5428 BS777-1 3639 54161111.1 2745 2.09 53.2 AS1111-1 4899 7290 TS1111-1 5116 7613 BS1111-1 5106 7599

Page1.10

Page 3: CP Jacket Single Conductor Power/Distribution Cable · IEEE 1202/FT4, IEEE 383, ... Single Conductor Power/Distribution Cable Type P, 600/1000/2000 volts ... 100ºC &110ºC Based

Single ConductorPower/Distribution CableType P, 600/1000/2000 voltsDRILMAR™ 125-XECrosslinked Polyolefin InsulatedDrilling Rig and Marine Cable

Ampacity Chart

1600 Distribution Dr., Duluth, GA 30097 Tel: 770-623-0001 Fax: 770-623-5789e-mail: [email protected] website: www.cmewire.com

AMPACITY

125ºC 110ºC 100ºC 95ºC

18 22 17 16 20

16 25 25 23 23

14 39 40 37 32

12 57 48 45 38

10 75 62 58 51

8 102 77 72 68

6 135 103 96 91

5 158 117 109 105

4 180 137 128 121

2 241 181 169 162

1 282 208 194 187

1/0 326 243 227 217

2/0 378 281 262 250

3/0 438 321 300 289

4/0 506 376 451 335

262 583 436 407 382

313 652 487 455 427

373 728 553 516 476

444 811 630 588 531

535 910 709 662 597

646 1018 783 731 671

777 1131 881 822 761

1111 1379 1098 1025 937

SizeAWG/kcmil

95ºC Based on Table 4/5C.10 of the 1997 ABS MODU rules and at 45°C ambient.

100ºC & 110ºC Based on IEEE Std 45, single bank per hanger at 45°C ambient.

125ºC Based on IEEE Std 843 for single conductor in free air, triplexed,with45°C ambient no sun and 2 ft/s air speed.

125ºC @ 45ºC 110ºC @ 45ºC 100ºC @ 45ºC 95ºC @ 45ºCambient in ambient in single ambient in single ambient

free air bank per bank per IEEE 45 IEEE 45

1) Derate factor for double bank N/A 0.80 0.80 N/A

2) Derate factor for 50ºC ambient 0.9682 0.9607 0.9534 0.9486

3) Derate factor for 55ºC ambient 0.9354 0.9198 0.9045 0.8944

4) Derate factor for 40ºC ambient 1.0307 1.0377 1.0444 1.0488