Covers & Specs - Woodstove · 2018. 11. 8. · WOODSTOCK SOAPSTONE STOVES OWNER’S MANUAL FIREVIEW...

4
WOODSTOCK SOAPSTONE STOVES OWNER’S MANUAL FIREVIEW MODEL 205 Woodstock Soapstone Company, Inc. 66 Airpark Road, West Lebanon, NH 03784 Toll Free 1-800-866-4344 • www.woodstove.com Rev 0618 Tested To UL 1482-2011 7th Edition Listed By PFS Corporation Tested and Listed by

Transcript of Covers & Specs - Woodstove · 2018. 11. 8. · WOODSTOCK SOAPSTONE STOVES OWNER’S MANUAL FIREVIEW...

  • WOODSTOCK SOAPSTONE STOVES

    OWNER’S MANUAL

    FIREVIEW MODEL 205

    Woodstock Soapstone Company, Inc.66 Airpark Road, West Lebanon, NH 03784

    Toll Free 1-800-866-4344 • www.woodstove.comRev 0618

    Tested To UL 1482-2011 7th EditionListed By PFS Corporation

    Tested and Listed by

  • OUR PROMISEWe are sure you will enjoy your new stove. During the first six monthsthat you own it, test its performance and experience the comfortablewarmth of soapstone. If you are not thoroughly delighted with thebeauty, quality, and energy efficiency of your stove, you may return itfor a full refund, including the cost of return freight. This is the bestconsumer protection plan in the industry.

    EPA APPROVALThis Manual describes the installation and operation of: the Model 205Fireview Catalytic Soapstone Stove.Model 205 Fireview Catalytic Soapstone Stove meets the U.S.Environmental Protection Agency’s emission limits for wood heaterssold after July 1, 1992. Under specific test conditions, this stove has beenshown to deliver heat at rates ranging from 13,400 to 40,500 BTU/hr.,and average emissions of 1.3 grams/hr.The Fireview model contains a catalytic combustor, which needs period-ic inspection and replacement for proper operation. It is against the lawto operate this woodstove in a manner inconsistent with the operatinginstructions in this manual, or if the catalytic element is deactivated orremoved.

    LISTING TO UL #1482Model 205 Fireview Catalytic Soapstone Stove has been tested to ULStandard #1482 7th edition 2011 for safety, and is listed by PFSCorporation. UL Standard #1482 is the standard for testing solid fuelheating appliances which is universally recognized by all national build-ing regulatory agencies (SBCC, BOCA, ICBO) and individual states. Please Note: Tested and Listed for US installations only

    LIMITED WARRANTYYour Woodstock Soapstone Stove will be carefully inspected before ship-ment. We will replace any part which is defective in material or work-manship, free of cost, for a period one year from the date of purchase. Ifa defect is discovered, please contact Woodstock Soapstone Company,Inc. for instructions regarding return or replacement of the defectivepart.

    CATALYTIC COMBUSTOR WARRANTYThe catalytic combustor in your Fireview Woodstove is fully warrantedfor three years from the date of purchase against any defect in work-manship or materials that prevent the combustor from functioningwhen installed and operated properly. The catalytic combustor is addi-tionally warranted for three years from the date of purchase for anydeterioration in the stainless steel substrate material. For instructionsregarding return or replacement of the catalytic combustor, please con-tact:

    Woodstock Soapstone Company, Inc.66 Airpark RoadWest Lebanon, NH 03768Phone: 1-800-866-4344 • Web: www.woodstove.com

    Tested and Listed by

  • MODEL 205 FIREVIEW CATALYTIC TABLE OF CONTENTS

    WARRANTY INFORMATION/CERTIFICATIONS.. . . . . . . . . . . Inside CoverEPA Certification, UL Listing, Warranty, Catalytic Combustor Warranty

    INSTALLATION... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11Installation, Location, Chimneys, Fireplace Installation, Clearance Table, WallProtection, Floor Protection, Mobile Home Installation

    OPERATION.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-15Setting up Your Stove, Seasoning Your Stove, Starting a Fire and EstablishingDraft, Engaging the Catalytic Combustor, Reloading & Overnight Burning, AshRemoval, Surface Thermometer, Overfiring, Daily Use, The Fall Away Handle,Firewood

    CATALYTIC COMBUSTOR.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-19How your Combustor Works, Inspection & Cleaning, Replacement, CatalyticProbe Thermometer, Frequently Asked Questions, Catalytic CombustorWarranty Information

    MAINTENANCE.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-22Stove, Stone & Glass Cleaning, Gasket Replacement, Routine Checks, End OfSeason Maintenance, Creosote

    TROUBLESHOOTING.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23-25

    SAFETY.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-27Overview, Installation, Smoke & The Chimney, Heat, Ash Removal,Precautions, Emergency Procedures

    PARTS LIST & DIAGRAMS.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-30

    SPECIFICATIONS.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back Cover

  • DIMENSIONS & SPECIFICATIONSH x W x D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28”x 26”x 20”Flue Exit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back OnlyFlue Size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .......... 6”Flue Height to Center (Back Vent). . . . . . . . . . . . 22.75”Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 485 lbs.Loading Door. . . . . . . . . . . . . . . . . . . Right Side StandardLoading Door Size (HxW). . . . . . . . . . . . . . . . 10.5”x8.25”Wood Length (Recommended). . . . . . . . . . . . . . . . . . 16”Firebox (H/W/D in inches) . . . . . . . . . . 14.5”x13”x20”Firebox Size. . . . . . . . . . . . . . . . . . . . . . . . . . 2.18 Cubic ft.Burn Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-12 hrs.Heat Output Range. . . . . . . . . . 10,000-55,000 BTU/hrArea Heated. . . . . . . . . . . . . . . . . . . . . . . 900-1,600 sq. ft.EPA Certified (Meets 2020 standards). . . . . . . . . . . YesListed to UL 1482. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes

    EPA Emissions Rating. . . . . . . . . . . . . . . . 1.3 grams/hrEPA Default Efficiency. . . . . . . . . . . . . . . . . . . . . . . . . 72%Catalytic Combustor . . . . . . . . . . . . . . . . . . . . . StandardAsh Pan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/ABack Clearance (no protection). . . . . . . . . . . . . . . . . . 30”Back Clearance (w/Heat Shield Kit) . . . . . . . . . . . . 18” Side Clearance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18”Mobile Home Approved. . . . . . . . . . . . . . . . . . . . . . . Yes

    22 3/4”

    26”26”

    28”28”

    20”

    18”

    24”

    outs

    ide,

    leg to

    leg