COTS Regulator Studies

15
COTS Regulator Studies Derek Donley*, Mitch Newcomer, Mike Reilly *Hospital of the University of Pennsylvania, Radiation Oncology

description

COTS Regulator Studies. Derek Donley*, Mitch Newcomer, Mike Reilly *Hospital of the University of Pennsylvania, Radiation Oncology. COTS Radiation survey (Background) . - PowerPoint PPT Presentation

Transcript of COTS Regulator Studies

Page 1: COTS Regulator Studies

COTS Regulator Studies

Derek Donley*, Mitch Newcomer, Mike Reilly

*Hospital of the University of Pennsylvania, Radiation Oncology

Page 2: COTS Regulator Studies

COTS Radiation survey (Background) 1. It is fairly well known that deep sub micron CMOS processes with thin gate oxide

exhibit a fairly strong resistance to radiation*. Also that CMOS processes are not inherently susceptible to bulk damage from Neutrons and Protons.

2. Along with thinner dimensions comes the benefit of lower capacitance an higher gain gm/i.

3. One additional characteristic is that silicon has an inherent breakdown field that can not be violated. So thinner gate oxides and feature sizes have resulted in lower supply voltages, mostly a good thing.

Although we don’t usually know what manufacturers are putting into their latest designs we thought it would be reasonable to look for fast opamps with low supply voltages to see if they might hold up to under high levels of ionizing radiation. Our first study in 2011 targeting CMOS opamps appropriate for the Phase 1 upgrade of the LAr electronics showed: that all of the opamps we selected meeting these critera were unaffected by a TID of up to 1MRad: OPA2835, LMH6611, THS4520 ADC driver. • See for instance the paper by the CERN micro electronics group: IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 46, NO 6, DECEMBER 1999

Page 3: COTS Regulator Studies

RegulatorsWith the LHC regulator experience behind us in our work on the TRT we thought that it might be useful to apply the same criteria and survey commercial regulators. 1) It wasn’t clear that the ST regulators would be available and 2) We felt that if commercial regulators could withstand the LAr radiation environment we would likely prefer the more modernized LDO’s. Regulators are more complex than opamps alone with internal reference voltages and high current capability so we expanded our study to include higher current transistors, voltage references, opamps and commercial regulators. Based on the criteria of expected thin gate oxide processes and high frequency operation. At the same time we were working with Bob Hollebeek at Penn on the design of a micromegas based proton therapy imaging detector for use at Penn’s proton therapy facility. As a result we have had some access during scheduled R&D periods to their 230MeV protons and the help and Expert for setup, focusing and calibration: Derek Dolney from Penn’s Radiation Oncology group.

Page 4: COTS Regulator Studies

Treatment Room (1 of 5)

Derek adjust Gurney to hold our apparatus

Page 5: COTS Regulator Studies

Hand wired Test Board with provision for 14 test devices. With flood exposure to all active devices we get 3.8 1010 per exposure period. Nov 25, 2013 After 15 runs with full flood exposure the dose was 5.7X1011

*Note that the board shown has only the two devices in the cross hairs mounted .

Page 6: COTS Regulator Studies

Graphs of Full Exposure

01000

20003000

40005000

60007000

80009000

10000

-2.70

-2.50

-2.30

-2.10

-1.90

-1.70

-1.50

MAX 1735 & TPS 7232(seconds , volts)

All Files 5s interval

TPS 7232Max 1735

Seconds

Volts

01000

20003000

40005000

60007000

80009000

100000.00

0.50

1.00

1.50

2.00

2.50

3.00

TPS 6001 & Max 1725(seconds , volts)

All Files 5s interval

TPS 6001max1725

Seconds

Volts

-2.5V

+2.5VBeam Monitor??

Seconds

Page 7: COTS Regulator Studies

Graphs of Full Exposure Cont.

0 2000 4000 6000 8000 100000.00

0.50

1.00

1.50

2.00

2.50

3.00

MAX6138(seconds , volts)

All Files 5s interval

max 6138 ch6max 6138 ch7

Seconds

Volts

0 1000 2000 3000 4000 5000 6000 7000 8000 900010000

-0.50

-0.40

-0.30

-0.20

-0.10

0.00

0.10

Mic 5271(seconds , volts)

All Files 5s interval

Seconds

Volts

The disturbance at 1800 seconds is due to the failure of the 1735 -2.5 due to over spec input voltage notradiation.

Page 8: COTS Regulator Studies

Failed Devices Significant voltage change below 5X1011 protons or 30 KRad BNL* gammas. • ADP3333 300mA positive LDO reg.• LT3032 150mA positive LDO reg.• MIC5271 100mA negative LDO reg. • UCC 284 500mA negative LDO reg. • UCC 384 500mA negative LDO reg.

• Jim Kierstead at BNL has been very helpful in receiving our setups, exposing them under power and returning then to us.

Page 9: COTS Regulator Studies

TPS74401 LDO 5.5V input Max 3A

Page 10: COTS Regulator Studies

TPS74xxx series Available as .5, 1.5 and 3A current

Page 11: COTS Regulator Studies

TPS74401 3A and TPS74201 1.5A TI LDO Regulators Pre - Proton Exposure at setup time.

Page 12: COTS Regulator Studies

3 hrs and 1.5X1012 (230MeV) Protons/cm2 Later

Page 13: COTS Regulator Studies

Data Logger

3077 1.200 1.200 1/27/2014 22:10:103077.2 1.200 1.200 1/27/2014 22:10:103077.4 1.200 1.200 1/27/2014 22:10:103077.6 1.200 1.200 1/27/2014 22:10:103077.8 1.200 1.200 1/27/2014 22:10:10

0.004951 0.00345 Seconds 74201 74401 Date Time

0 1.210 1.200 1/27/2014 22:25:250.2 1.210 1.200 1/27/2014 22:25:250.4 1.200 1.200 1/27/2014 22:25:250.6 1.210 1.200 1/27/2014 22:25:250.8 1.200 1.200 1/27/2014 22:25:25

759.4 1.210 1.200 1/27/2014 22:38:04759.6 1.200 1.200 1/27/2014 22:38:04759.8 1.200 1.200 1/27/2014 22:38:04

760 1.200 1.200 1/27/2014 22:38:05760.2 1.210 1.200 1/27/2014 22:38:05760.4 1.210 1.200 1/27/2014 22:38:05

0.000224 0.000576 Seconds 74201 74401 Date Time

0 1.200 1.200 1/27/2014 21:18:530.2 1.200 1.200 1/27/2014 21:18:530.4 1.200 1.200 1/27/2014 21:18:530.6 1.200 1.200 1/27/2014 21:18:530.8 1.200 1.200 1/27/2014 21:18:53

1 1.200 1.200 1/27/2014 21:18:54

0 1.3X1012 Protons/cm2 1.3 1.5X1012 Protons/cm2

Page 14: COTS Regulator Studies

TPS74xxx series Total Proton fluence 1.5X1012

0.5, 1.5, 3amp Adjustable slow turn on Regulators

0 100 200 300 400 500 600 700 800

-4.000E-03

-2.000E-03

0.000E+00

2.000E-03

4.000E-03

6.000E-03

8.000E-03

1.000E-02

1.200E-02

TPS 1.2V regulators 230MeV proton Exposure #7 (1.3-->1.5X1012P/cm2)

TPS74401 TPS74201

[Vout -1.2V]

Seconds

RMS V during exposure <1mV

Page 15: COTS Regulator Studies

Conclusions• This report is on the Survey part of our COTS regulator study. • The next stage is to select devices for use and perform studies on a statistically

significant sample. ~20 parts of each candidate device. It looks like there are several candidate positive regulators with the TPS74XXX series being most versatile, stable and radiation tolerant up to the 1.5X1012 fluence tested so far. Calculations of an equivalent ionization dose of only 80KRad will require additional ionizing radiation to get to the 300KRad (with safety factor) required for the LAr Front End Crate environment.

Only one negative regulator candidate has been identified so far. MAX1735 200mA max regulators. It may be possible to shunt some current around it via resistor to bring the max current drive up to 300mA.