CORNER - Knight Frank

4
DELTA CORNER ANNEX ALONG RING ROAD, WESTLANDS FOR FURTHER INFORMATION PLEASE CONTACT Richard Ngunjiri T: +254 20 423 9288 M: +254 72 562 5042 [email protected] www.knightfrank.com Sports Road Sports Road Ring Road Rhapta Road Rhapta Road Lantana Road Mpaka Road Crossway Mpaka Road Westlands Road Woodvale Groove Woodvale Groove Ring Road Parklands Road Muthithi Groove Mithithi Road Westlands Ave Waiyaki Way Waiyaki Way Westlands Ave Parklands Baptist Church Oracle Tower Capital West Fogo Gaucho Kipro Centre Westlands Stage Fortis Towers Uchumi Westlands The Mall Westlands Sankara Hotel Jacaranda Hotel Villa Care DELTA CORNER ANNEX DISCLAIMER Knight Frank give notice that: 1. No description or information given whether or not in these Particulars and whether written or verbal (“information”) about the property or its condition or its value may be relied upon as a statement or representation of fact. Neither Knight Frank (nor any joint agents) have any authority to make any representations and accordingly any information given is entirely without responsibility on the part of the agents or the seller(s) or lessor(s). 2. Contents and information contained in this brochure are intended for general marketing only and should not be relied upon by any person as being correct or accurate. 3. These particulars do not constitute, nor constitute part of, an offer or contract, nor shall they merge in any offer or contract which may be made between the sellers or lessors and the recipient of the information. 4. The photographs show only certain parts of the property at the time they were taken. Any areas measurements or distances given are approximate only. 5. Any reference to alterations to, or use of any part of the property is not a statement that any necessary planning, building regulations or other consent has been obtained. These matters must be verified by any intending buyer or lessee. 6. Any buyer or lessee must satisfy himself by inspection or otherwise as to the correctness of any information given.

Transcript of CORNER - Knight Frank

Page 1: CORNER - Knight Frank

DELTACORNERANNEXALONG RING ROAD, WESTLANDS

FOR FURTHER INFORMATIONPLEASE CONTACT

Richard NgunjiriT: +254 20 423 9288M: +254 72 562 [email protected]

www.knightfrank.com

Sports Road

Sports Road

Ring Road

Rhapta Road

Rhapta Road

Lantana Road

Mpaka Road

Crossway

Mpaka Road

Westlands Road

Woodvale Groove

Woodvale Groove

Ring Road

Parklands Road

Muthithi Groove

Mithithi Road

Westlands Ave

Waiyaki Way

Waiyaki Way

Westlands Ave

ParklandsBaptist Church

OracleTower

Capital West

Fogo Gaucho

KiproCentre

WestlandsStage

Fortis Towers

UchumiWestlands

The Mall Westlands

SankaraHotel

JacarandaHotel

Villa Care DELTACORNERANNEX

DISCLAIMERKnight Frank give notice that:1. No description or information given whether or not in these Particulars and whether written

or verbal (“information”) about the property or its condition or its value may be relied upon as a statement or representation of fact. Neither Knight Frank (nor any joint agents) have any authority to make any representations and accordingly any information given is entirely without responsibility on the part of the agents or the seller(s) or lessor(s).

2. Contents and information contained in this brochure are intended for general marketing only and should not be relied upon by any person as being correct or accurate.

3. These particulars do not constitute, nor constitute part of, an offer or contract, nor shall they merge in any offer or contract which may be made between the sellers or lessors and the recipient of the information.

4. The photographs show only certain parts of the property at the time they were taken. Any areas measurements or distances given are approximate only.

5. Any reference to alterations to, or use of any part of the property is not a statement that any necessary planning, building regulations or other consent has been obtained. These matters must be verified by any intending buyer or lessee.

6. Any buyer or lessee must satisfy himself by inspection or otherwise as to the correctness of any information given.

Page 2: CORNER - Knight Frank

The Delta Corner Annex is strategically located along Ring Road Westlands and is adjacent to the iconic Oracle Tower. It is across the highway from Westlands, within minutes of the Nairobi CBD and at the epicentre of an area that is quickly becoming a major business district of Nairobi. The building has a two way access; from either Ring Road or Waiyaki Way. The area is served well by both public and private transport and is very close to local amenities including The Mall, Sarit Centre and Westgate Shopping Centre and five star hotels. A number of major office users dominate the locality including financial, legal, insurance, banking, UN and diplomatic missions.

Delta Corner Annex is a commanding modern office complex offering high quality and flexible business accommodation designed to enhance your working lifestyle. The development has a total lettable space of 77,500 sq. ft spread over six floors. The complex offers high quality office accommodation, designed to International standards, offering the tenant a secure, highly efficient and flexible working environment.

Attractive amenities include; standby generators, borehole, passenger lifts, security check & CCTV surveillance, electric fence, fire alarm and detection system. Delta Corner Annex will be modern and state-of-the-art place of work in a one-of-a-kind location. It will comprise of Grade A building specifications with serious commitment to the environment. With one of the best parking ratios, Delta Corner Annex will provide its tenants with a prestigious, functional, and convenient environment. This property is positioned to meet the needs of today’s corporate and professional firms, specifically targeting institutions from the discerning and security- conscious NGO/international community. It is perfectly designed to accommodate both world-class corporations seeking unique headquarters and elite international bodies seeking a full-floor identity in unique and tranquil surrounds.

AN IMPRESSIVE ADDRESS

01

• Grade ‘‘A’’ office• Flexible floor plates widening the range

of potential occupiers• 3 parking bays per 100m2 of office

space• Main power connections with backup

generators• State-of-the-art fire protection and fire-

fighting services• 2 High speed ThyssenKrupp (13

passenger, 1000 kg capacity) to service all floors

• 24 hour security and provision for CCTV surveillance

• Standard services include WC’s (Male, Female, Disabled) and kitchen/cleaner rooms

• Two fire escape staircases with the third being the main staircase

• 440 KVA standby generator• Air conditioning provision• Slab to slab height of 3.6 meters

02

TECHNICAL SPECIFICATIONS

Page 3: CORNER - Knight Frank

Notes:

1. This drawing is copyright2. Do not scale off this drawing3. All levels and dimensions to be checked on site before any building work commences4. Any discrepancies to be reported to the office of the consultant5. All work to be strictly in accordance to with the standard specifications and notes6. This drawing is to be read in conjunction with specifications and all other relevant drawings7. Walls below 200mm thick to be reinforced with hoop iron at every alternate course8. Depth of foundations to be decided on site9. pv denotes permanent air vents over doors and windows as shown on drawings

Civil Engineer's drawings

between masonry and r.c. work

13. All sanitary works to the entire satisfaction of MoH

12. All reinforced concrete work to Structural Engineer's buildings to be encased in 150mm thick concrete sorround11. Drain pipes passing under tarmac, driveways, and

10. A single layer of 3-ply bituminous felt to be provided

drawings

Project Title:

Client:

Architect:

Registration No.____________________

Signature:_________________________

IPDC/026

Scale:

JT

Date:

Drawn:

Job No.

omasetChecked:

07 September 2016

Drawing Title:

Revision No.

Drawing No.

04

P.O. BOX 1575 - (502), Nairobi, Kenya.

GARDEN PROPERTIESPO BOX 22401-00100 NAIROBI

PROPOSED AMMENDMENTSTO OFFICES AND PARKING SPACEON PLOT LR.NO 1870/X/106 & 107.A LONG RING ROAD,WESTLANDS

A1355

24 x 150 = 3,600

1

2

3

4

567891011121314151617181920

21

22

23

24

F

F

D

D

E

E

C

C

33

11

22

44

55

66

77

B

B

H

H

G

G

G

G

H

H

B

B

A

A

77

66

55

44

22

33

11

C

C

D

D

E

E

F

F

24 x 150 = 3,600

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24 x 150 = 3,600

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

7,050

200 18,308 200 16,196

26,54

9

50,250

1,330 m2

24 m2

28 m2

26 m2Firefightingequipment

stack pipe provision

stack pipe provision

stack pipe provision

stack pipe provision

stack pipe provision

Fire fighting equipment

stack pipe provision

AC platforms

AC platforms

AC platforms

AC platforms

Fire fighting equipment

Fireescape

GentsLIFTSHAFT

Ladie

s LIFTSHAFT

TYPICAL FLOORS 3rd to 7th floor L[--]06

Lift lobby

pv pv

pvKitchen

Elect.ducts

pv

pv

CleanersKitchen

Mech

. Duc

ts

VOID VOID

OFFICE SPACE

Typical floor

MP - 05

LETTABLE AREAS

03

FLOOR USER NET (SQM)LIFT LOBBY (SQM)

AMENITIES(SQM)

TOTAL AREA (SQM)

TOTAL AREA (SQFT)

Sub Basement Car Parking - 69 No. - 39 15 54 581

Ground Floor Let to RMA - - - - -

Mezzanine Floor

Let to RMA - - - - -

Parking 1 Car parking - 61 No. - 39 15 54 581

Parking 2 Parking - 58 No. - 39 15 54 581

1st Office 1,330 24 54 1,408 15,154

2nd Office 1,330 24 54 1,408 15,154

3rd Office 1,330 24 54 1,408 15,154

4th Office 1,330 24 54 1,408 15,154

5th Office 1,330 24 54 1,408 15,154

TOTAL 6,650 237 315 7,202 77,513

TYPICAL FLOOR

04

Page 4: CORNER - Knight Frank

Notes:

1. This drawing is copyright2. Do not scale off this drawing3. All levels and dimensions to be checked on site before any building work commences4. Any discrepancies to be reported to the office of the consultant5. All work to be strictly in accordance to with the standard specifications and notes6. This drawing is to be read in conjunction with specifications and all other relevant drawings7. Walls below 200mm thick to be reinforced with hoop iron at every alternate course8. Depth of foundations to be decided on site9. pv denotes permanent air vents over doors and windows as shown on drawings

Civil Engineer's drawings

between masonry and r.c. work

13. All sanitary works to the entire satisfaction of MoH

12. All reinforced concrete work to Structural Engineer's buildings to be encased in 150mm thick concrete sorround11. Drain pipes passing under tarmac, driveways, and

10. A single layer of 3-ply bituminous felt to be provided

drawings

Project Title:

Client:

Architect:

Registration No.____________________

Signature:_________________________

IPDC/026

Scale:

JT

Date:

Drawn:

Job No.

omasetChecked:

03 October 2016

Drawing Title:

Revision No.

Drawing No.

04

P.O. BOX 1575 - (502), Nairobi, Kenya.

GARDEN PROPERTIESPO BOX 22401-00100 NAIROBI

PROPOSED AMMENDMENTSTO OFFICES AND PARKING SPACEON PLOT LR.NO 1870/X/106 & 107.A LONG RING ROAD,WESTLANDS

A1355

24 x 150 = 3,600

1

2

3

4

567890111213141516171819102

21

22

23

24

G

G

H

H

B

B

A

A

7

6

5

4

2

1

3

C

C

E

E

D

D

F

F

F

F

E

E

D

D

C

C

1

3

2

4

5

6

7

A

A

B

B

H

H

G

G

24 x 150 = 3,600

1

2

3

4

5

6

7

8

9

10

11

21

13

14

15

16

17

18

19

20

21

22

23

24 x 150 = 3,600

1

2

3

4

5

6

7

8

9

10

11

21

13

14

15

16

17

18

19

20

21

22

23

7,000 8,600 8,600 8,600 8,600 8,600 8,600

5,598

6,300

6,000

4,000

10,00

04,0

00

6,300

6,000

4,000

10,00

0

200

26,55

020

0

200

6,650

200

200

5,215

200

1,235

200

26,30

0

200

1,800

100

2,650

150

1,950

200

17,091 200 18,308 200 16,196

200 2,100 200 15,221 200 4,508 200 8,400 200 5,000 200 15,871450 200

2,100 200

200 24,229 200 2,400 200 23,221 200

201

12,32

420

014

,025

200

200 24,225 200 25,825 200

24 m2

336 Sqm 358 Sqm

275 Sqm287 Sqm

Fire fighting equipment

AC platforms

AC platforms

AC platforms

AC platforms

stack pipe provision

stack pipe provision

stack pipe provision

stack pipe provision

stack pipe provision

stack pipe provision

Fire fighting equipment

stack pipe provision

Firefightingequipment

OFFICE SPACEOFFICE SPACE

Mech

. Duc

ts

OFFICE SPACE

Fireescape

GentsLIFT

SHAFT

Ladie

s

LIFTSHAFT

TYPICAL FLOORS 3rd to 7th floor L[--]06

OFFICE SPACE

Lift lobby

pv pv

Kitchen

Elect.ducts

KitchenCleaners

VOIDVOID

Corr

idoh

31Sq

m

TYPICAL FLOOR PLAN

TYPICAL FLOOR - SUBDIVIDED

05 06

CAR PARKING

Notes:

1. This drawing is copyright2. Do not scale off this drawing3. All levels and dimensions to be checked on site before any building work commences4. Any discrepancies to be reported to the office of the consultant5. All work to be strictly in accordance to with the standard specifications and notes6. This drawing is to be read in conjunction with specifications and all other relevant drawings7. Walls below 200mm thick to be reinforced with hoop iron at every alternate course8. Depth of foundations to be decided on site9. pv denotes permanent air vents over doors and windows as shown on drawings

Civil Engineer's drawings

between masonry and r.c. work

13. All sanitary works to the entire satisfaction of MoH

12. All reinforced concrete work to Structural Engineer's buildings to be encased in 150mm thick concrete sorround11. Drain pipes passing under tarmac, driveways, and

10. A single layer of 3-ply bituminous felt to be provided

drawings

Project Title:

Client:

Architect:

Registration No.____________________

Signature:_________________________

IPDC/026

Scale:

JT

Date:

Drawn:

Job No.

omasetChecked:

07 September 2016

Drawing Title:

Revision No.

Drawing No.

04

P.O. BOX 1575 - (502), Nairobi, Kenya.

GARDEN PROPERTIESPO BOX 22401-00100 NAIROBI

PROPOSED AMMENDMENTSTO OFFICES AND PARKING SPACEON PLOT LR.NO 1870/X/106 & 107.A LONG RING ROAD,WESTLANDS

A1355

24 x 150 = 3,600

1

2

3

4

567891011121314151617181920

21

22

23

24

24 x 150 = 3,600

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24 x 150 = 3,600

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

F

F

D

D

E

E

C

C

3

1

2

4

5

6

7

B

B

H

H

G

G

G

G

H

H

B

B

A

A

7

6

5

4

2

3

1

C

C

D

D

E

E

F

F

200 7,525 1,900 5,950 39,475 200 5,875 200

200

5,648

5,996

12,16

06,0

005,9

3520

0

200 500 200

36,13

9

61,225

2,148 m2

Fire fighting equipment

Fire fighting equipment

DRIVE WAY

power floated concrete

power floated concrete

RAMP

DRIVE WAY

LIFTSHAFT

LIFTSHAFT

Lift lobby

Elec

t. duc

tsMe

ch. D

ucts

150 m

m hig

h rais

ed pl

atfor

m

ReceptionStore

Disabledwc

RAM

PD

rivew

ay

FIRST FLOOR L[--]0561 parkings

Fireescape

Going dow

n

DELT

A TO

WER

Base

ment

venti

lationGoi

ng u

p

1st floor parking

MP - 04