Page 1: Copyright © 2001-2012 Anviz Global Inc. USA. Single device controls lock directly, use exit button to go out: T5Pro + Lock +Exit button Advantage: easy.

Copyright © 2001-2012 Anviz Global Inc. USA

Page 2: Copyright © 2001-2012 Anviz Global Inc. USA. Single device controls lock directly, use exit button to go out: T5Pro + Lock +Exit button Advantage: easy.

Single device controls lock directly, use exit button to go out:

T5Pro + Lock +Exit button

Advantage: easy to install and operate, cost-effective, could support fingerprint orcard or fingerprint+card verification method.

Disadvantage: without keypad or LCD, can’t input ID or display message. Can only record the IN record because we use EXIT button to go out.Not with high safety, just need to break T5Pro to cut off lock power supply, then door would be open.

This solution is a good choice for small rooms inside the company building while there is already an outside security system exists. For example, at the companygate we already have another access control system to make sure only permitted person could enter into the building. So it doesn’t require very high security level and just use this solution to separate room from other rooms.

Of course we could use other models with relay output in this solution instead of T5Pro if you need keypad or other features.

Page 3: Copyright © 2001-2012 Anviz Global Inc. USA. Single device controls lock directly, use exit button to go out: T5Pro + Lock +Exit button Advantage: easy.

Use access controller to control one device and lock, use exit button to go out:

SC011 + T50M + EXIT button + Lock

Advantage: Higher safety, device doesn’t control lock directly, even someone breaks the outside device by force, lock won’t open. Lock get power supply from SC011, so it couldprotect the device main board from the electric shock while lock power and off, thus it could prolong the device service life.

Disadvantage: can only record the IN record

Specially T5 doesn’t have relay out, it should work with SC011 or other models which havewiegand input. But please NOTE: we need to set device wiegand mode as “Anviz Wiegand”,and also we need to register device in SC011. The registration is much easier than before,please refer to the SC011 manual.

T50M and VF30 with waterproof cover could be installed outside the house, they couldwork well in terrible weather condition like heavy rain.

Page 4: Copyright © 2001-2012 Anviz Global Inc. USA. Single device controls lock directly, use exit button to go out: T5Pro + Lock +Exit button Advantage: easy.

Two device work together, one for in and one for out:

Solution 1: VF30 + T5S + lock + emergency exit button

Advantage: employee has to clock in and clock out, could record both IN and OUT records. The inside device could control lock, so it’s also with high safety. This solution also supports anti-passback function. We just need to register user in the master reader, T5S only works as external reader.

Disadvantage: all records generate on VF30, sometimes clients need to record the INand OUT state, this solution can’t realize this.

Right now, only VF30/VP30/T60 could work with T5S to realize anti-passback function.This solution could be used in buildings which need high security level.

Page 5: Copyright © 2001-2012 Anviz Global Inc. USA. Single device controls lock directly, use exit button to go out: T5Pro + Lock +Exit button Advantage: easy.

Two device work together, one for in and one for out:

Solution 2: T60 + OA1000 + Lock + Emergency exit button

Advantage: we could use complicated verify mode for both IN and OUT. Outsidedevice use wiegand communication to send user data to inside master reader, so itis with high safety. Good appearance and remarkable time attendance and accesscontrol feature.

Disadvantage: The registration way is different. Because all outside slaver reader would send virtual card ID to inside master reader no matter we user fingerprint orcard. So we need to register on slave reader first, and register the virtual card ID in the inside master reader. The inside master reader would have all records, but theIN/OUT state would depend on its actual state.

Here we use lock control power supply APC123 to provide power for OA1000 and also to control lock. Could improve system security and protect device.

Page 6: Copyright © 2001-2012 Anviz Global Inc. USA. Single device controls lock directly, use exit button to go out: T5Pro + Lock +Exit button Advantage: easy.

Two device work together, one for in and one for out:

Solution 3: VF30 + OA1000 + SC011 + Emergency exit button

Advantage: could make all records state in one device is IN, and another is OUT.Use APC123 to provide power supply and control lock, high safety system, and couldalso protect device from electric shock while lock power on and off.

Diadvantage: cost more than other solution

Page 7: Copyright © 2001-2012 Anviz Global Inc. USA. Single device controls lock directly, use exit button to go out: T5Pro + Lock +Exit button Advantage: easy.
Page 8: Copyright © 2001-2012 Anviz Global Inc. USA. Single device controls lock directly, use exit button to go out: T5Pro + Lock +Exit button Advantage: easy.
Page 9: Copyright © 2001-2012 Anviz Global Inc. USA. Single device controls lock directly, use exit button to go out: T5Pro + Lock +Exit button Advantage: easy.

For anti-passback, we only need to connect T5S RS485 to VF30/VP30/T60 RS485.And only need to register user in VF30/VP30/T60.