HET Safety DevicesHET Safety DevicesHET Safety DevicesHET Safety Devices

SAFETY DEVICES forSAFETY DEVICES forSAFETY DEVICES forSAFETY DEVICES for

HEAVY EQUIPMENT HEAVY EQUIPMENT HEAVY EQUIPMENT HEAVY EQUIPMENT

and TRUCKand TRUCKand TRUCKand TRUCK HET = Heavy Equipment & Truck

Page 2: Copy of 3. Safety Devices HET-1.pdf

• HET Safety Devices adalah alat atau sekumpulan komponen elektrik yangdirancang dan dibuat untuk mencegah atau mengurangi resiko terjadinyakecelakaan pada alat berat dan operatornya.

• Safety Devices terdiri dari :

1. Operator Safety Devices :

Operator Fatigue Warning

Strobe Light

Overtaking Lamp

Fog Lamp

D e s c r i p t i o n

Fog Lamp

LED Rear Combination Lamp

2. Machine Safety Devices

Roll Over Shutdown

Idle Timer

Lockout Switch

Emergency Shutdown

3. Power Supply Unit

24VDC Power Distribution Unit

12VDC Radio Converter

4. Wiring Harness

Page 3: Copy of 3. Safety Devices HET-1.pdf

Characteristic Design

Karakteristik rancang bangun dari HET Safety Devices adalah

sbb :

1. Memenuhi (compliance) terhadap standard safety

industry dan alat berat.

2. Integrated System

3. Ready to Fit.3. Ready to Fit.

4. Easy to Fit.

5. Fool Proof.

6. Reliable.

7. Modular System.

8. Customized Design.

9. Free Maintenance.

10. Memenuhi standard safety wiring harness dan

pemasangan.

Page 4: Copy of 3. Safety Devices HET-1.pdf

Power Distribution Unit (PDU)Power Distribution Unit (PDU)Power Distribution Unit (PDU)Power Distribution Unit (PDU)

Product Features

• PDU berfungsi untuk mendistribusikanelectric power dari terminal B+ dan ACCpada starting switch (kunci kontak) kedevices yang akan dipasang.

• Dengan dipasangnya PDU, maka tidakakan terjadi penumpukan ataupemotongan kabel pada kunci kontak danpemotongan kabel pada kunci kontak danpower lainnya, jika jumlah devices yangdipasang dan membutuhkan arus daribattery cukup banyak.

• Aman, PDU dilengkapi dengan CircuitBreaker 10 Amp, 20 Amp, 30 Amp (jumlahcircuit breaker dan kapasitasnya diatursesuai dengan kebutuhan) yangberfungsi sebagai pemutus arus otomatisjika terjadi hubungan pendek padadevices maupun wiring harness-nya.

PDU Model Lama

PDU Console Model Baru

Circuit Breaker

Page 5: Copy of 3. Safety Devices HET-1.pdf

Product Features

Placement of Power Distribution Unit (HD785-7 & HD465-7R)

Power

Distribution

Unit (PDU)

Circuit Breaker

Pada Dump truck HD785-7 & HD465-7R, Power Distribution Unit diletakkandibawah passenger seat dandimounting dgn baut.

Page 6: Copy of 3. Safety Devices HET-1.pdf

Product Features

Power Distribution Unit 9 Circuit BreakerApplied for all Unit Model

WIRING DIAGRAM

POWER DISTRIBUTION UNIT 9 CB

POWER DISTRIBUTION UNIT

KEY SWITCH

B+

B+

B+

ACC

ACC

B+

ACC

ACC

ACC

to FIP CONTROLLER

CONNECTION

Page 7: Copy of 3. Safety Devices HET-1.pdf

Rollover Shutdown System, Included Idle Timer

Product Features Machine Safety Devices

• Berfungsi untuk mematikan enginedengan cara memutus supply aruske ACC dan BR system jika unitberada pada kemiringan tertentu,sehingga mengurangi resikokerusakan fatal dan kebakaran padaengine dan komponen komponenengine dan komponen komponenlain.

• Aktif pada 45 derajat (Dump Truck,Wheel Loader, Grader) dan 90derajat (Dozer, Excavator, BigDigger).

• Easy to Fit.• Melindungi unit dari kemungkinan

terbalik (rollover).• Melindungi operator dari kecelakaan

fatal.

Page 8: Copy of 3. Safety Devices HET-1.pdf

Product Features Machine Safety Devices

Idle Timer

Idle timer dirancang untuk membuatputaran engine tetap idle selamawaktu yang ditentukan sebelumengine shutdown. Idle timer berfungsi setelah starting switch dioff kan.

Idle timer akan membuat engine tetap running untuk coolling down pada saat starting switch off sehingga akan melindungi diesel engine dan komponen-komponenturbo dari kemungkinan kerusakanyang lebih cepat.

Page 9: Copy of 3. Safety Devices HET-1.pdf

Lockout Lockout Lockout Lockout SwitchSwitchSwitchSwitch

Product Features Machine Safety Devices

Lock out switch adalah pemutus arus manualdari starting key ke starting system dengansystem pengunci mekanis untuk membuatengine tidak bisa distart terutama pada saatunit tersebut memerlukan perbaikan.

Emergency ShutdownEmergency ShutdownEmergency ShutdownEmergency Shutdown

Emergency shutdown adalah komponenyang digunakan untuk mematikan enginesecara langsung pada saat terjadikeadaan darurat.

Page 10: Copy of 3. Safety Devices HET-1.pdf

Fatigue Fatigue Fatigue Fatigue Warning SystemWarning SystemWarning SystemWarning System• Adalah system peringatan yang di rancang untuk mempertahankan

tingkat kewaspadaan operator di dalam mengoperasikan alat berat.

• System secara berkala memberikan peringatan di dalam bentuk suarabuzzer dan lampu indicator (LED) yang mengharuskan operator harusbergerak untuk mereset setiap kali system peringatan ini bekerja. Periode peringatan bisa di atur sesuai dengan kebutuhan tingkatkewaspadaan yang di kehendaki.

• Komponen utama dari system ini adalah :

Product Features Operator Safety Devices

• Komponen utama dari system ini adalah :

> Programmable Logic Control Timer

> 60db Buzzer alarm

> Blinking LED Lamp

> Reset switch

Page 11: Copy of 3. Safety Devices HET-1.pdf

Strobe Light Strobe Light Strobe Light Strobe Light

Product Features Operator Safety Devices

Strobe Light berfungsi untuk memberi tandabahwa unit tersebut sedang beroperasi.Biasanya warna amber dipasang pada unit-unityang bergerak pada kecepatan tinggi, sepertiDump Truck, Grader. Warna biru biasa dipasangpada unit-unit yang bergerak pada kecepatanrendah, seperti Dozer, Excavator, Big Digger,rendah, seperti Dozer, Excavator, Big Digger,Wheel Loader.

Overtaking lamp berfungsi untuk memberitahukepada operator unit dibelakangnya bahwa kondisidi depan unit aman untuk didahului.

Overtaking LampOvertaking LampOvertaking LampOvertaking Lamp

Page 12: Copy of 3. Safety Devices HET-1.pdf

Product Features Operator Safety Devices

HID Working Lamp

35 watt, 24Volt3200 lumen output (4x halogen bulb)1500 – 3000 recommended bulb life10 x halogen bulb life time

• Effective Recommendation MEANS Saving Cost

• Halogen Lamps become HID lamps• Halogen Lamps become HID lamps

• Halogen produce ~ 25 Lu/watt(70W 24V H3 1.750 Lu)Efficacy = 25

• 24V 70W halogen life is typically 300

Engine hours. This 44 unscheduled

Maintenance stop per light

• HID produce ~ 91 Lu/watt(35W 24V D1S 3.200 Lu)Efficacy = 91

• HID D1S bulb life typically 4000

Engine hours. This 3 unscheduled

maintenance stop per light and you have an improvement level of light output

Page 13: Copy of 3. Safety Devices HET-1.pdf

HALOGEN SINGLE BEAM HALOGEN TWIN BEAM HID FOR WHEEL BASE HID FOR TRACKLINK BASE

Product Features Working Lamp

ABL 500 SERIES

ABL 1100 SERIES

ABL 1500 SERIESABL 500 HID SERIES SPEAKER

A9700 SERIES

Page 14: Copy of 3. Safety Devices HET-1.pdf

Fog Fog Fog Fog LampLampLampLamp

Product Features Operator Safety Devices

Fog Lamp berfungsi sebagai penerangan unit padasaat kondisi berkabut.

35 watt, 24Volt

3200 lumen output (4x halogen bulb)1500 – 3000 recommended bulb life

10 x halogen bulb life time

LED Rear Combination Lamp

Lampu LED combination untukTurn, Tail, and Stop Lamp.

Keuntungan LED, lebih terang, tahan lama, menghilangkandown time penggantian bulb.

Page 15: Copy of 3. Safety Devices HET-1.pdf

Product Features

Converter 24 to 12VDCConverter 24 to 12VDCConverter 24 to 12VDCConverter 24 to 12VDC

Converter berfungsi untuk menurunkantegangan dari 24VDC ke 12VDC. Output power dari converter dapatdigunakan untuk radio komunikasi.

Output 12 VDC

for Radio

Communication

Page 16: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Installation HD785-7

Placement of Lighting (Front View)

Strobe

LampAmber

HID Fog

Lamp

HIDForwardLamp

Page 17: Copy of 3. Safety Devices HET-1.pdf

Placement of Lighting (Rear View)

Overtaking

Safety Devices Installation HD785-7

LED Rear Combination

Lamp

Lamp

Page 18: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Installation HD785-7

Placement of Rollover Shutdown System & Fatigue Warning System (FWS)at HD785-7 HD465-7R

Fatigue Warning System &

Rollover Shutdown

Page 19: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Installation HD785-7

Placement of Lockout Switch & Emergency Shutdown

Page 20: Copy of 3. Safety Devices HET-1.pdf

Haulpak 730E

Safety Devices Installation 730E

Page 21: Copy of 3. Safety Devices HET-1.pdf

HID Fog Lamp & HID Working Lamp

Safety Devices Installation Haulpak 730E

HID Working Lamp

HID Fog

Lamp

Page 22: Copy of 3. Safety Devices HET-1.pdf

Fatigue Warning System & Rollover Shutdown System

Safety Devices Installation Haulpak 730E

Fatigue Warning &

Rollover Shutdown

Power Distribution

Unit

Page 23: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Installation Haulpak 730E

Emergency Shutdown & Lockout Switch

Emergency

Shutdown

Lockout

Switch

Penempatan pada lokasi yang mudahdijangkau dari gorund level (tanah)

Page 24: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Installation PC2000-8

Page 25: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Installation PC2000-8

LCD Monitor for Rear Camera (Optional Devices)

Page 26: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Installation PC2000-8

Placement of Controller Set

Page 27: Copy of 3. Safety Devices HET-1.pdf

Menggunakan 2 jenis connector:

1. Deutch Connector

Digunakan disemua koneksi dari Power Distribution Unit ke semuadevices yang akan dipasang.

Wiring Harness Features Connector Standard

Standard pemasangan:

a. Crimping tools menggunakan Special Deutch Connector Crimping Tools.

Page 28: Copy of 3. Safety Devices HET-1.pdf

Wiring Harness Features Connector Standard

b. Deutch Connector dilengkapi dengan rubber seal untuk mencegah debu dan air masuk ke dalam connector.

c. Posisi Deutch Connector pada pemasangan di unit horizontal, untuk menecegah air masuk ke dalam connector.

Page 29: Copy of 3. Safety Devices HET-1.pdf

Wiring Harness Features Connector Standard

2. Automotive Connector

Digunakan pada panel-panel seperti toggle switch, warning lamp, buzzer, serta pada Ground Terminal.

Automotive connector

Automotive connector

pada LED pre warning

indicator Fatigue Warning

Page 30: Copy of 3. Safety Devices HET-1.pdf

Wiring Harness:

1. Single core cable 3 mm diameter.� Structure 16/0.32 , conductor cross sec. area 1.287 mm2

2. Single core cable 4 mm diameter.� Structure 26/0.32 , conductor cross sec. area 2.091 mm2

Spesifikasi UT Wiring Harness:

1. Panjang wiring harness dibuat customized sesuai dengan original

Wiring Harness Features

1. Panjang wiring harness dibuat customized sesuai dengan original OEM harness routing untuk setiap unit model.

Page 31: Copy of 3. Safety Devices HET-1.pdf

2. Seluruh outside cabin harness menggunakan harness guard protective tubing jenis unsplit (tidak terbelah).

Wiring Harness Features

Harness guard protective tubing

3. Seluruh inside cabin harness menggunakan PVC Sleeve Tubing.

PVC sleeve tubing

Page 32: Copy of 3. Safety Devices HET-1.pdf

3. Pada ujung tubing, baik yang inside cabin maupun outside cabin diberi heatshrink, dan pada ujung-ujung heatshrink diikat dengan kabel ties.

Wiring Harness Features

4. Jarak antara deutsch connector dan harness guard ± 3 inch.

Page 33: Copy of 3. Safety Devices HET-1.pdf

5. Semua sambungan pada tubing di tutup menggunakan heatshrink dancable ties.

Wiring Harness Features

6. Penyambungan antar kabel menggunakan solder.

7. Wiring harness yang melewati plat besi, pada lubang plat besi diberigrommet, sehingga saat bergesekan dengan plat tidak akan lecet.

Menggunakan gromet

Page 34: Copy of 3. Safety Devices HET-1.pdf

Semua pemasangan connector akan terlebih dahulu diolesi dengan Grease Anti Corrosion

Wiring Harness Features

34

Grease Anti Corrosion

Page 35: Copy of 3. Safety Devices HET-1.pdf

Wiring and Accessories Switches

1. Single Pole, Single Throw Toggle Switch (On-Off)

2. Single Pole, Double Throw Toggle Switch (On-Off-On)

Page 36: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Standard by Unit Model HD785-7 & HD465-7R

Page 37: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Standard by Unit Model HM400-1

Page 38: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Standard by Unit Model D155A-6 & D375A-5

Page 39: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Standard by Unit Model PC750SP-8 & PC1250SP-8

Page 40: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Standard by Unit Model GD825A-2

Page 41: Copy of 3. Safety Devices HET-1.pdf

Safety Devices Standard by Unit Model WA500-3