control & genset paralleling - anels catalogue · 2018. 9. 7. · AUTOMATIC CONTROL PANELS FOR...
Transcript of control & genset paralleling - anels catalogue · 2018. 9. 7. · AUTOMATIC CONTROL PANELS FOR...
panels
AUTOMATIC CONTROL PANELS
FOR GENERATORS
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
AUTOSTART PANELS AUTO MAINS FAILURE PANELS AUTO TRANSFER SWITCH
catalogue
2018 2019
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
CONTENTS
CRE ATS PANELS .............................................................. 2 CRE AUTOSTART PANELS ................................................... 6 CRE AMF PANELS ............................................................ 10
Please contact us for shipping costs and information. You can check our sales terms and conditions on the CRE TECHNOLOGY website:http://www.cretechnology.com/en/p/33/the-company/Sales-terms
cre TECHNOLOGY panels
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
BENEFITS
• User friendly each command with own button, own led indicator and intuitive keyboard
• History Events log (250) and data- logger• Fully programmable by keyboard• 12 month warranty• Intelligent Fast setup menu.
COMPOSITION
• 1 Metal case 15/10 thick painted by epoxy powder RAL7042
• 1 Power transfer switch available in 2 different solu-tions:
- lnterlocked power contactors (25A to 160A)- or SOCOMEC change over switch (250A to 3200A)
• 1 Automatic battery charger (12 VDC or 24 VDC)• 9 Protection fuses fox auxiliary• 5 Digital outputs with relays• 1 Alarm Buzzer• 1 On/Off key• 3 Ampermetric transformers• 1 Emergency button• 1 ICGEN2.0 controller
ENVIRONMENT (ICGEN 2.0)• Operating temperature range: -30°C ... +70°C• Ambient protection IP55• Range VDC: 8-35 / Range VAC: 50-500• Measurements TRMS: 0,2% ±1digit• Built-in conformity to EN60439-1
SPECIAL FUNCTIONS ON BOARD• Remote start/stop• Timer start/stop for programmable daily or weekly
starts/stops• SCR/EJP: remote start with group contactor closure
even if the mains is present• Start/Stop of the genset by kW threshold• Programmable digital inputs (5)• Programmable static outputs (5)
ELECTRICAL PROTECTIONS (ICGEN 2.0)
• Ground protection alarm• Test active / Test failed• Battery maintenance / Battery charger alarm• Faulty mains / Emergency button• Feedback KG / KR• System locked / Faulty start• Low/High frequency generator & voltage generator• Wrong phase sequence generator• Current overload / short-circuit• Low/High frequency & voltage mains• Wrong phase sequence mains• User alarm 1 / 2 / 3
GENERAL• Date and time• CRE TECHNOLOGY or customer logo• Informations page / Events log / Active alarms page• Warranty expiry
ALTERNATORS MEASURES• VAC: L1/L2-L2/L3-L3/L1• VAC: L1N - L2N - L3N• kVA/kW/kVAR/Cos.fi: L1-L2-L3• kWh / Hz• Autonomy/Work/KG work hours• Amper: L1 - L2 - L3
LOAD MEASURES• VAC: L1/L2-L2/L3-L3/L1• VAC: L1N-L2N-L3N• kVA/kW/kVAR/Cos.fi: L1-L2-L3• kWh/Hz
MAINS MEASURES • VAC, kVA, kW, kVAR, kWh, COS(j), Hz
DIRECTIVES • EN61000-6-(2), (4) - EN60086-2-2• IEC61000-4-(2), (3), (4), (5), (6)• IEC60086-2- (1), (2), (6) + IEC60086-2-30 - CISPR 16-1
RELATED PRODUCTS & CABLESCRE MONITOR SOFTWARE – Ref A70Z4BATTERY CHARGERS BP+ 305 05XXM RANGEBATTERY CHARGERS BPRB XXXXM RANGE
cre ats panelsAutomatic transfer switch panels - From 0 to 3200A
Part number: A63Z2 / ICGENT4XXXX -12/24-0 /ICGENM4XXXX - 12/24-2
This series of panels offers manual and automatic
management for backup generators and utility
network. All the utility network’s parameters are
monitored and, in case of failure, the controller
will open mains source from the load andsend a
remote start signal to start the generator.
When the voltage reaches a programmed limit,
genset contactor is immediately closed on load.
Once a safe mains signal is present, the controller
opens the genset contactor, transfers the load to
the mains and removes the remote start signal, to
stop the generator after the programmable timer.
3 DIFFERENT VERSION FROM 0 TO 3200A:
• ATS Control panel (without circuit breakers)
• ATS panel with 2 contactors (25A to 160A)
• ATS panel with motorised transfer switch (250A
to 3200)
ICGEN 2.0 MODULE
ATS PANEL
FEATURES
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
• Diesel or gas generators• All standby power applications, all refit projects requiring automatic transfer switch on mains failure
APPLICATIONS
cre ats panels
FRONT DOOR WITH ICGEN 2.0 MODULE
INTERNAL VIEWATS CONTROL PANEL
INTERNAL VIEWATS WITH CONTACTORS
(25A TO 3200A)
INTERNAL VIEWCONTROL PANEL WITH MOTORIZED TRANSFER SWITCH (25A TO 3200A)
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
REFERENCES
cre ats panelsAutomatic transfer switch panels - From 0 to 3200A
Part number: A63Z2 / ICGENT4XXXX -12/24-0 /ICGENM4XXXX - 12/24-2
WIRING DIAGRAM
REFERENCE CRE TECHNOLOGY PANEL*
AkVA
(400VAC
3ph + N)
kVA
(230VAC
3ph + N)V
DCPANEL SIZE POWER CONTROL BRAND CHARGER
CRE TECHNOLOGY DRAWINGS
kg
ICGEN400-12/24-0 0 0 0 12 - 24 600-400-250 WITHOUT WITHOUT BP+05... ATS-SC01 16
ICGENT40017-12/24-0 25 17 10 12 - 24 600-400-250 CONTACTORS LS BP+05... ATS-01 20
ICGENT40025-12/24-0 40 28 16 12 - 24 600-400-250 CONTACTORS LS BP+05... ATS-01 20
ICGENT40042-12/24-0 60 42 24 12 - 24 600-400-250 CONTACTORS LS BP+05... ATS-01 20
ICGENT40055-12/24-0 80 55 32 12 - 24 750-500-250 CONTACTORS LS BP+05... ATS-01 25
ICGENT40070-12/24-0 100 70 40 12 - 24 750-500-250 CONTACTORS LS BP+05... ATS-01 30
ICGENT40093-12/24-0 135 93 54 12 - 24 750-500-250 CONTACTORS LS BP+05... ATS-01 35
ICGENT40111-12/24-0 160 111 64 12 - 24 800-600-300 CONTACTORS LS BP+05... ATS-01 40
ICGENM40173-12/24-0 250 173 99 12 - 24 800-600-300 MOTORIZED TRANSFER SWITCH SOCOMEC BP+05... ATS-02 60
ICGENM40277-12/24-0 400 277 159 12 - 24 1000-600-450 MOTORIZED TRANSFER SWITCH SOCOMEC BP+05... ATS-02 75
ICGENM40436-12/24-0 630 436 251 12 - 24 1000-600-450 MOTORIZED TRANSFER SWITCH SOCOMEC BP+05... ATS-02 80
ICGENM40554-12/24-0 800 554 318 12 - 24 1000-600-450 MOTORIZED TRANSFER SWITCH SOCOMEC BP+05... ATS-02 160
ICGENM40692-12/24-0 1000 692 398 12 - 24 1800-800-600 MOTORIZED TRANSFER SWITCH SOCOMEC BPRB10... ATS-02 200
ICGENM40865-12/24-0 1250 865 497 12 - 24 1800-800-600 MOTORIZED TRANSFER SWITCH SOCOMEC BPRB10... ATS-02 250
ICGENM41107-12/24-0 1600 1107 637 12 - 24 1800-800-600 MOTORIZED TRANSFER SWITCH SOCOMEC BPRB10... ATS-02 250
ICGENM41384-12/24-0 2000 1384 796 12 - 24 2000-1000-800 MOTORIZED TRANSFER SWITCH SOCOMEC BPRB10... ATS-02 280
ICGENM41730-12/24-0 2500 1730 995 12 - 24 2000-1000-800 MOTORIZED TRANSFER SWITCH SOCOMEC BPRB10... ATS-02 320
ICGENM42214-12/24-0 3200 2214 1273 12 - 24 2000-1000-800 MOTORIZED TRANSFER SWITCH SOCOMEC BPRB10... ATS-02 400
* REFERENCE CRE TECHNOLOGY PANEL + ICGEN 2.0 + RELAYS OUTPUTS
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
cre ats panels Automatic transfer switch panels - From 0 to 3200APart number: A63Z2 / ICGENT4XXXX -12/24-0 /ICGENM4XXXX - 12/24-2
BATTERY CHARGES
CRE TECHNOLOGY’s range of battery chargers is designed to supply voltage to the battery with a permanent connection and a maximum of efficiency.
4 RANGES
The BP+305, Compact, BP and the BPRB series are available:• From 3A to 40A in 12VDC or 24VDC
• Single or three-phase input, all chargers support 50Hz and 60Hz• Voltage input range from 85VAC to 550VAC
PRGRAMMING
CRE MONITORThe CRE MONITOR Software is a PC Windows based Software which al-low to control, adjust and monitor the AC/IC/TCGEN 2.0 modules. Even if the AC/ICGEN 2.0 display allow to configure all parameters through its display and buttons on the front panel, this PC software offer a much easier way of programming and displaying, and allow to upload and dowload configuration files.It also offer scada features with all electrical and mechanical parame-ters available in the control module.
RELATED PRODUCT
BP + 305 RANGE
The BP+ battery chargers range offers a range of input voltages in singlephase, a range of output current from 3A to 10A and voltage output from 12VDC to 24VDC.
They integrate a permanent short-circuit protection and accept wit-hout damage the electrical starters inrush current. Their ergonomic design allows you to easily integrate it into your plant thanks to their lightness, compactness and Din Rail support.• With Diode integrated• Can be installed on DIN Rail• Competitive price
REFE
RENC
ES
OUTP
UT C
URRE
NT
OUTP
UT V
OLTA
GE
DC V
OLTA
GE
ADJU
STAB
LE
INPU
T VO
LTAG
E RA
NGE
INPU
T FR
EQUE
NCY
RANG
E
EFFI
CIEN
CY
(TYP
ICAL
)
WOR
KING
TE
MPE
RATU
RE
STOR
AGE
TE
MPE
RATU
RE
WID
TH
HEIG
HT
DEPT
H
WEI
GHT
FAIL
URE
RELA
Y
BOOS
T M
ODE
(ACT
IVAT
ED B
Y EX
TERN
AL
CONT
ACT)
UNIT A VDC
- VAC
Hz % °C °C mm mm mm kg -
BP+ 305 RANGE
BP+ 0512M-305 5 12 - 15 Yes 90 ~ 305 47 - 63 83 -20 / +70 -40 / +85 32 125.2 102 0.51 No No
BP+ 0324M-305 3 24 - 28 Yes 90 ~ 305 47 - 63 87 -20 / +70 -40 / +85 32 125.2 102 0.51 No No
BP+ 1012M-305 10 24-28 Yes 90 ~ 305 47 - 63 84 -20 / +70 -40 / +85 40 125.2 113.5 0.57 No No
BP+ 0524M-305 5 24 - 28 Yes 90 ~ 305 47 - 63 87 -20 / +70 -40 / +85 40 125.2 113.5 0.57 No No
BP+ 1024M-305 10 24 - 28 Yes 90 ~ 305 47 - 63 87 -20 / +70 -40 / +85 63 125.2 113.5 1 No No
cre autostart panels
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
cre ats panels
BENEFITS
• User friendly each command with own button, own led indicator and intuitive keyboard
• History Events log (250) and data- logger• Fully programmable by keyboard• 12 month warranty• Intelligent Fast setup menu.
COMPOSITION
• 1 Metal case 15/10 thick painted by epoxy powder RAL7042
• 1 Power contactors (25A to 3200A)• 1 Automatic battery charger (12 VDC or 24 VDC)• 9 Protection fuses fox auxiliary• 3 Digital outputs with relays• 2 Digital outputs with power relays for cranck and fuel• 1 Alarm Buzzer• 1 On/Off key• 3 Ampermetric transformers• 1 Emergency button• 1 ACGEN2.0 controller
ENVIRONMENT (ACGEN 2.0)• Operating temperature range: -30°C ... +70°C• Ambient protection IP55• Range VDC: 8-35 / Range VAC: 50-500• Measurements TRMS: 0,2% ±1digit• Built-in conformity to EN60439-1
SPECIAL FUNCTIONS ON BOARD (ACGEN 2.0)• Remote start/stop• Timer start/stop for programmable daily or weekly
starts/stops• Start/Stop of the genset by kW threshold• Programmable digital inputs (5)• Programmable static outputs (3)
ELECTRICAL PROTECTIONS (ACGEN 2.0)
• Ground protection alarm• Test active / Test failed• Battery maintenance /
Battery charger alarm• Emergency button• Feedback KG • System locked / Faulty start• Low/High frequency generator & voltage generator• Wrong phase sequence generator• Current overload / short-circuit• User alarm 1 / 2 / 3
GENERAL (ACGEN 2.0)• Date and time• CRE TECHNOLOGY or customer logo• Informations page / Events log / Active alarms page• Warranty expiry
ALTERNATORS MEASURES• VAC: L1/L2-L2/L3-L3/L1• VAC: L1N - L2N - L3N• kVA/kW/kVAR/Cos.fi : L1-L2-L3• kWh / Hz• Autonomy/Work/KG work hours• Amper: L1 - L2 - L3
LOAD MEASURES (ACGEN 2.0)• VAC: L1/L2-L2/L3-L3/L1• VAC: L1N-L2N-L3N• kVA/kW/kVAR/Cos.fi : L1-L2-L3• kWh/Hz
DIRECTIVES (ACGEN 2.0)• EN61000-6-(2), (4) - EN60086-2-2• IEC61000-4-(2), (3), (4), (5), (6)• IEC60086-2- (1), (2), (6) + IEC60086-2-30 - CISPR 16-1
RELATED PRODUCTS & CABLESCRE MONITOR SOFTWARE – Ref A70Z4BATTERY CHARGERS BP+ 305 05XXM RANGEBATTERY CHARGERS BPRB XXXXM RANGE
cre autostart panelsAuto start panels - From 0 to 3200A
Part number: A63Z1 / ASM-ACGEN400-12/24-0 / ASM-ACGEN4XXXX-12/24-0
This series of panels offer manual and automatic
starting and stopping control for genset.
All engines parameters are monitored and the
controller will operate cranking, fuel valve control,
engine speed monitoring and protection as well
as electrical protection while on load.
This panel is compatible with all engines in the
market and is an economic alternative for refit.
Panels are available in 2 different versions from
0 to 3200A:
• AUTOSTART panel (without circuit breaker)
• AUTOSTART panel (with contactor) ACGEN 2.0 MODULE
AUTOSTART CONTROL PANEL
FEATURES
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
• Diesel or gas generators• Installation refit
APPLICATIONS
cre autostart panels
FRONT DOOR WITH ACGEN 2.0 MODULE
INTERNAL VIEWCONTROL PANEL
INTERNAL VIEWCONTROL PANEL WITH CONTACTOR
(25A TO 3200A)
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
REFERENCES
cre autostart panelsAutomatic start panels - From 0 to 3200A
Part number: A63Z1 / ASM-ACGEN400-12/24-0 / ASM-ACGEN4XXXX-12/24-0
WIRING DIAGRAM
REFERENCE CRE TECHNOLOGY PANEL*
AkVA
(400VAC
3ph + N)
kVA
(230VAC
3ph + N)V
DCPANEL SIZE POWER CONTROL BRAND CHARGER
CRE TECHNOLOGY DRAWINGS
kg
ASM-ACGEN400-12/24-0 0 0 0 12 - 24 600-400-250 WITHOUT WITHOUT BP+05... ASM-SC01 20
ASM-ACGEN40017-12/24-0 25 17 10 12 - 24 600-400-250 CONTACTORS LS BP+05... ASM-01 20
ASM-ACGEN40028-12/24-0 40 28 16 12 - 24 600-400-250 CONTACTORS LS BP+05... ASM-01 35
ASM-ACGEN40042-12/24-0 63 42 24 12 - 24 600-400-250 CONTACTORS LS BP+05... ASM-01 45
ASM-ACGEN40055-12/24-0 80 55 32 12 - 24 750-500-250 CONTACTORS LS BP+05... ASM-01 65
ASM-ACGEN40070-12/24-0 100 70 40 12 - 24 750-500-250 CONTACTORS LS BP+05... ASM-01 65
ASM-ACGEN40017-12/24-0 135 93 54 12 - 24 750-500-250 CONTACTORS LS BP+05... ASM-01 70
ASM-ACGEN40111-12/24-0 160 111 64 12 - 24 800-600-300 CONTACTORS LS BP+05... ASM-01 135
ASM-ACGEN40173-12/24-0 250 173 99 12 - 24 800-600-300 CONTACTORS LS BP+05... ASM-01 135
ASM-ACGEN40277-12/24-0 400 277 159 12 - 24 1000-600-450 CONTACTORS LS BP+05... ASM-01 135
ASM-ACGEN40436-12/24-0 630 436 251 12 - 24 1000-600-450 CONTACTORS LS BP+05... ASM-01 140
ASM-ACGEN40554-12/24-0 800 554 318 12 - 24 1000-600-450 CONTACTORS LS BP+05... ASM-01 140
ASM-ACGEN40692-12/24-0 1000 692 398 12 - 24 1800-800-600 CONTACTORS LS BPRB10... ASM-01 160
ASM-ACGEN40865-12/24-0 1250 865 497 12 - 24 1800-800-600 CONTACTORS LS BPRB10... ASM-01 280
ASM-ACGEN41107-12/24-0 1600 1107 637 12 - 24 1800-800-600 CONTACTORS LS BPRB10... ASM-01 300
ASM-ACGEN41384-12/24-0 2000 1384 796 12 - 24 2000-1000-800 CONTACTORS LS BPRB10... ASM-01 330
ASM-ACGEN41730-12/24-0 2500 1730 995 12 - 24 2000-1000-800 CONTACTORS LS BPRB10... ASM-01 380
ASM-ACGEN42214-12/24-0 3200 2214 1273 12 - 24 2000-1000-800 CONTACTORS LS BPRB10... ASM-01 440
* REFERENCE CRE TECHNOLOGY PANEL + ACGEN 2.0 + RELAYS OUTPUTS
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
cre autostart panels Automatic start panels - From 0 to 3200APart number: A63Z1 / ASM-ACGEN400-12/24-0 / ASM-ACGEN4XXXX-12/24-0
BATTERY CHARGES
CRE TECHNOLOGY’s range of battery chargers is designed to supply voltage to the battery with a permanent connection and a maximum of efficiency.
4 RANGES
The BP+305, Compact, BP and the BPRB series are available:• From 3A to 40A in 12VDC or 24VDC
• Single or three-phase input, all chargers support 50Hz and 60Hz• Voltage input range from 85VAC to 550VAC
PRGRAMMING
CRE MONITORThe CRE MONITOR Software is a PC Windows based Software which al-low to control, adjust and monitor the AC/IC/TCGEN 2.0 modules. Even if the AC/ICGEN 2.0 display allow to configure all parameters through its display and buttons on the front panel, this PC software offer a much easier way of programming and displaying, and allow to upload and dowload configuration files.It also offer scada features with all electrical and mechanical parame-ters available in the control module.
RELATED PRODUCT
BP + 305 RANGE
The BP+ battery chargers range offers a range of input voltages in singlephase, a range of output current from 3A to 10A and voltage output from 12VDC to 24VDC.
They integrate a permanent short-circuit protection and accept wit-hout damage the electrical starters inrush current. Their ergonomic design allows you to easily integrate it into your plant thanks to their lightness, compactness and Din Rail support.• With Diode integrated• Can be installed on DIN Rail• Competitive price
REFE
RENC
ES
OUTP
UT C
URRE
NT
OUTP
UT V
OLTA
GE
DC V
OLTA
GE
ADJU
STAB
LE
INPU
T VO
LTAG
E RA
NGE
INPU
T FR
EQUE
NCY
RANG
E
EFFI
CIEN
CY
(TYP
ICAL
)
WOR
KING
TE
MPE
RATU
RE
STOR
AGE
TE
MPE
RATU
RE
WID
TH
HEIG
HT
DEPT
H
WEI
GHT
FAIL
URE
RELA
Y
BOOS
T M
ODE
(ACT
IVAT
ED B
Y EX
TERN
AL
CONT
ACT)
UNIT A VDC
- VAC
Hz % °C °C mm mm mm kg -
BP+ 305 RANGE
BP+ 0512M-305 5 12 - 15 Yes 90 ~ 305 47 - 63 83 -20 / +70 -40 / +85 32 125.2 102 0.51 No No
BP+ 0324M-305 3 24 - 28 Yes 90 ~ 305 47 - 63 87 -20 / +70 -40 / +85 32 125.2 102 0.51 No No
BP+ 1012M-305 10 24-28 Yes 90 ~ 305 47 - 63 84 -20 / +70 -40 / +85 40 125.2 113.5 0.57 No No
BP+ 0524M-305 5 24 - 28 Yes 90 ~ 305 47 - 63 87 -20 / +70 -40 / +85 40 125.2 113.5 0.57 No No
BP+ 1024M-305 10 24 - 28 Yes 90 ~ 305 47 - 63 87 -20 / +70 -40 / +85 63 125.2 113.5 1 No No
cre aMF panels
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
cre autostart panels
BENEFITS
• User friendly each command with own button, own led indicator and intuitive keyboard
• History Events log (250) and data- logger• Fully programmable by keyboard• 12 month warranty• Intelligent Fast setup menu.
COMPOSITION• 1 Metal case 15/10 thick painted by epoxy powder
RAL7042• 1 Power transfer switch proposed in 2 different
solutions:- lnterlocked power contactors (25A to 160A)- or SOCOMEC change over switch (250A to 3200A)
• 1 Automatic battery charger (12 VDC or 24 VDC)• 9 Protection fuses fox auxiliary• 3 Digital outputs with relays• 2 Digital outputs with power relays for cranck and fuel• 1 Alarm Buzzer• 1 On/Off key• 3 Ampermetric transformers• 1 Emergency button• 1 TCGEN2.0 controller
ENVIRONMENT (TCGEN 2.0)• Operating temperature range: -30°C ... +70°C• Ambient protection IP55• Range VDC: 8-35 / Range VAC: 50-500• Measurements TRMS: 0,2% ±1digit• Built-in conformity to EN60439-1
SPECIAL FUNCTIONS ON BOARD (TCGEN 2.0)• Remote start/stop• Timer start/stop for programmable daily or weekly
starts/stops• SCR/EJP: remote start with group contactor closure
even if the mains is present• Start/Stop of the genset by kW threshold• Cranking/fuel valve control• Engine monitoring• J1939• Programmable digital inputs (5)• Programmable static outputs (5)
ELECTRICAL PROTECTIONS (TCGEN 2.0)• Ground protection alarm• Test active / Test failed• Battery maintenance /
Battery charger alarm• Faulty mains / Emergency button• Feedback KG / KR• System locked / Faulty start• Low/High frequency generator & voltage generator• Wrong phase sequence generator• Current overload / short-circuit• Low/High frequency & voltage mains• Wrong phase sequence mains• User alarm 1 / 2 / 3
GENERAL (TCGEN 2.0)• Date and time• CRE TECHNOLOGY or customer logo• Informations page / Events log / Active alarms page• Warranty expiry
ALTERNATORS MEASURES (TCGEN 2.0)• VAC: L1/L2-L2/L3-L3/L1• VAC: L1N - L2N - L3N• kVA/kW/kVAR/Cos.fi: L1-L2-L3• kWh / Hz• Autonomy/Work/KG work hours• Amper: L1 - L2 - L3
LOAD MEASURES (TCGEN 2.0)• VAC: L1/L2-L2/L3-L3/L1• VAC: L1N-L2N-L3N• kVA/kW/kVAR/Cos.fi: L1-L2-L3• kWh/Hz
MAINS MEASURES (TCGEN 2.0)• VAC, kVA, kW, kVAR, kWh, COS(j), Hz
DIRECTIVES (TCGEN 2.0)• EN61000-6-(2), (4) - EN60086-2-2• IEC61000-4-(2), (3), (4), (5), (6)• IEC60086-2- (1), (2), (6) + IEC60086-2-30 - CISPR 16-1
RELATED PRODUCTS & CABLESCRE MONITOR SOFTWARE – Ref A70Z4BATTERY CHARGERS BP+ 305 05XXM RANGEBATTERY CHARGERS BPRB XXXXM RANGE
cre aMF panelsAutomatic mains failure panels - From 0 to 3200A
Part number: A63Z0 / AA-TCGEN4XX -12/24-0 / AA-TCGENT4XXXX - 12/24-0 / AA-TCGENM4XXXX - 12/24-0
This series of panels offer manual and automatic
management for backup generator and utility
network, including engine management &
protections. All utility network’s parameters are
monitored and, in case of failure, the controller
will open mains source from the load and manage
starting sequence of the generator. When the
genset is ready, contactor is immediately closed
on load.
Once a safe mains signal is present, the controller
opens the genset contactor, transfers the load to
the mains and cools down the generator before
stopping.
Panels are available in 3 different versions from
0 to 3200A:
• AMF Control panel (without power breakers)
• AMF panel with 2 contactors (25A to 160A)
• AMF panel with motorized transfer switch
(250A to 3200)
TCGEN 2.0 MODULE
AMF PANEL
FEATURES
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
• Diesel or gas generators,• All standby power applications, all refit projects requiring automatic transfer switch on mains failure and engine start
sequence management
APPLICATIONS
cre aMF panels
FRONT DOOR WITH TCGEN 2.0 MODULE
INTERNAL VIEWAMF CONTROL PANEL
INTERNAL VIEWAMF WITH CONTACTORS
(25A TO 3200A)
INTERNAL VIEWCONTROL PANEL WITH MOTORIZED TRANSFER SWITCH (25A TO 3200A)
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
REFERENCES
cre aMF panelsAutomatic mains failure panels - From 0 to 3200A
Part number: A63Z0 / AA-TCGEN4XX -12/24-0 / AA-TCGENT4XXXX - 12/24-0 / AA-TCGENM4XXXX - 12/24-0
WIRING DIAGRAM
REFERENCE CRE TECHNOLOGY PANEL*
AkVA
(400VAC
3ph + N)
kVA
(230VAC
3ph + N)V
DCPANEL SIZE POWER CONTROL BRAND CHARGER
CRE TECHNOLOGY DRAWINGS
kg
AA-TCGEN400-12/24-0 0 0 0 12 - 24 600-400-250 WITHOUT WITHOUT BP+05... AMF-SC01 20
AA-TCGENT40017-12/24-0 25 17 10 12 - 24 600-400-250 CONTACTORS LS BP+05... AMF-01 20
AA-TCGENT40028-12/24-0 40 28 16 12 - 24 600-400-250 CONTACTORS LS BP+05... AMF-01 20
AA-TCGENT40042-12/24-0 63 42 24 12 - 24 600-400-250 CONTACTORS LS BP+05... AMF-01 30
AA-TCGENT40055-12/24-0 80 55 32 12 - 24 750-500-250 CONTACTORS LS BP+05... AMF-01 40
AA-TCGENT40070-12/24-0 100 70 40 12 - 24 750-500-250 CONTACTORS LS BP+05... AMF-01 40
AA-TCGENT40093-12/24-0 135 93 54 12 - 24 750-500-250 CONTACTORS LS BP+05... AMF-01 40
AA-TCGENT40111-12/24-0 160 111 64 12 - 24 800-600-300 CONTACTORS LS BP+05... AMF-01 65
AA-TCGENM0173-12/24-0 250 173 99 12 - 24 800-600-300 MOTORIZED TRANSFER SWITCH SOCOMEC BP+05... AMF-02 65
AA-TCGENM0277-12/24-0 400 277 159 12 - 24 1000-600-450 MOTORIZED TRANSFER SWITCH SOCOMEC BP+05... AMF-02 135
AA-TCGENM0436-12/24-0 630 436 251 12 - 24 1000-600-450 MOTORIZED TRANSFER SWITCH SOCOMEC BP+05... AMF-02 135
AA-TCGENM0554-12/24-0 800 554 318 12 - 24 1000-600-450 MOTORIZED TRANSFER SWITCH SOCOMEC BP+05... AMF-02 150
AA-TCGENM0692-12/24-0 1000 692 398 12 - 24 1800-800-600 MOTORIZED TRANSFER SWITCH SOCOMEC BPRB10... AMF-02 170
AA-TCGENM0865-12/24-0 1250 865 497 12 - 24 1800-800-600 MOTORIZED TRANSFER SWITCH SOCOMEC BPRB10... AMF-02 300
AA-TCGENM1107-12/24-0 1600 1107 637 12 - 24 1800-800-600 MOTORIZED TRANSFER SWITCH SOCOMEC BPRB10... AMF-02 320
AA-TCGENM1384-12/24-0 2000 1384 796 12 - 24 2000-1000-800 MOTORIZED TRANSFER SWITCH SOCOMEC BPRB10... AMF-02 350
AA-TCGENM1730-12/24-0 2500 1730 995 12 - 24 2000-1000-800 MOTORIZED TRANSFER SWITCH SOCOMEC BPRB10... AMF-02 400
AA-TCGENM2214-12/24-0 3200 2214 1273 12 - 24 2000-1000-800 MOTORIZED TRANSFER SWITCH SOCOMEC BPRB10... AMF-02 460
* REFERENCE CRE TECHNOLOGY PANEL + TCGEN 2.0 + RELAYS OUTPUTS
CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCEPhone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - [email protected]
cre aMF panelsAutomatic mains failure panelsPart number: A63Z0 / AA-TCGEN4XX -12/24-0 / AA-TCGENT4XXXX - 12/24-0 / AA-TCGENM4XXXX - 12/24-0
BATTERY CHARGES
CRE TECHNOLOGY’s range of battery chargers is designed to supply voltage to the battery with a permanent connection and a maximum of efficiency.
4 RANGES
The BP+305, Compact, BP and the BPRB series are available:• From 3A to 40A in 12VDC or 24VDC
• Single or three-phase input, all chargers support 50Hz and 60Hz• Voltage input range from 85VAC to 550VAC
PRGRAMMING
CRE MONITORThe CRE MONITOR Software is a PC Windows based Software which al-low to control, adjust and monitor the AC/IC/TCGEN 2.0 modules. Even if the AC/ICGEN 2.0 display allow to configure all parameters through its display and buttons on the front panel, this PC software offer a much easier way of programming and displaying, and allow to upload and dowload configuration files.It also offer scada features with all electrical and mechanical parame-ters available in the control module.
RELATED PRODUCT
BP + 305 RANGE
The BP+ battery chargers range offers a range of input voltages in singlephase, a range of output current from 3A to 10A and voltage output from 12VDC to 24VDC.
They integrate a permanent short-circuit protection and accept wit-hout damage the electrical starters inrush current. Their ergonomic design allows you to easily integrate it into your plant thanks to their lightness, compactness and Din Rail support.• With Diode integrated• Can be installed on DIN Rail• Competitive price
REFE
RENC
ES
OUTP
UT C
URRE
NT
OUTP
UT V
OLTA
GE
DC V
OLTA
GE
ADJU
STAB
LE
INPU
T VO
LTAG
E RA
NGE
INPU
T FR
EQUE
NCY
RANG
E
EFFI
CIEN
CY
(TYP
ICAL
)
WOR
KING
TE
MPE
RATU
RE
STOR
AGE
TE
MPE
RATU
RE
WID
TH
HEIG
HT
DEPT
H
WEI
GHT
FAIL
URE
RELA
Y
BOOS
T M
ODE
(ACT
IVAT
ED B
Y EX
TERN
AL
CONT
ACT)
UNIT A VDC
- VAC
Hz % °C °C mm mm mm kg -
BP+ 305 RANGE
BP+ 0512M-305 5 12 - 15 Yes 90 ~ 305 47 - 63 83 -20 / +70 -40 / +85 32 125.2 102 0.51 No No
BP+ 0324M-305 3 24 - 28 Yes 90 ~ 305 47 - 63 87 -20 / +70 -40 / +85 32 125.2 102 0.51 No No
BP+ 1012M-305 10 24-28 Yes 90 ~ 305 47 - 63 84 -20 / +70 -40 / +85 40 125.2 113.5 0.57 No No
BP+ 0524M-305 5 24 - 28 Yes 90 ~ 305 47 - 63 87 -20 / +70 -40 / +85 40 125.2 113.5 0.57 No No
BP+ 1024M-305 10 24 - 28 Yes 90 ~ 305 47 - 63 87 -20 / +70 -40 / +85 63 125.2 113.5 1 No No
www.cretechnology.com
EXPERT IN GENERATOR SOLUTION
PANELS CATALOGUE_EN_A2018