Consultants Legend for Drawings Reference Plans Drawi ... · GUG Gutter Guard - Refer M&F Schedule...
Transcript of Consultants Legend for Drawings Reference Plans Drawi ... · GUG Gutter Guard - Refer M&F Schedule...
-
Rev Date Description Drawing TitleProject
Revision
Drawing No.
Project No.Notes
CD.A00.01
1709
Date
17 - 21 Garfield Road,Woodridge Qld 4114
December 2017
Department of Housing &Public WorksHHS HPW 2017 - 006
Logan Youth Foyer Cover Sheet07
547
1 03
4007
547
1 03
4304
18 8
76 3
9404
12 1
27 9
04in
fo@
bark
desi
gn.c
om.a
uw
ww
.bar
kdes
ign.
com
.au
Tel
epho
neF
acsi
mile
Ste
ve G
uthr
ieLi
ndy
Atk
inE
mai
lW
eb
Bar
k D
esig
n A
rchi
tect
s
Que
ensl
and
Aus
tral
ia 4
567
PO
Box
135
5N
oosa
Hea
dsUse figured dimensionsin preference to scale. Alldimensions to be varifiedand checked on site.These designs,drawings,specifications and thecopyright thereof are theproperty of Bark DesignPty Ltd and must not beused, retained or copiedwithout the writtenauthority of Bark DesignPty Ltd. 3668 (SG)3664 (LA)
Registration No.Architects
RAIA Member 28409
Scale 1:1, 1:142.49, 1:2000, 1:200 @ A1
Contract Documentation - Not for Construction
Approved By: LA, SG
Drawn By: MR
F
C/OV
C/OV
F
F
F
F
F
F
F
F
F
C/OV
C/OV
C/OV
C/OV
C/OV
C/OV
C/OV
C/OV
Sheet A03.01
Sheet A03.03
Sheet A03.03
Sheet A03.04
Unit 40
Unit 39
Unit 36
Unit 35
Unit 32
Unit 31
Unit 28
Unit 27
BUILDING1
BUILDING3
BUILDING4
BUILDING5
Sheet A10.01
Sheet A03.02
Sheet A10.02Stair & Walkway 2
BUILDING2
Sheet A10.03Stair & Walkway 3
Unit 44
Unit 43
Stair & Walkway 1
Legend for Drawings
Awn Fibre Cement Awning -Refer M&F Schedule & Structural Documentation
AC Air Conditioning Unit - Refer Mechanical DrawingsASPT Asphalt - Refer Civil DocumentationBal# Metal Balustrade Type - Refer M&F ScheduleBHD BulkheadBth J# Bathroom Joinery TypeBRS# Brick Screen Type -
Refer M&F Schedule & Structural DocumentationBP# Brick Pier Type -
Refer M&F Schedule & Structural DocumentationBV# Brick Veneer Wall Type -
Refer M&F Schedule & Structural DocumentationBW# Blockwork Wall Type -
Refer M&F Schedule & Structural DocumentationC Cooker - Refer Appliances ScheduleCBD Cupboard - Refer Joinery DrawingsCD Clothes Drying Line - Refer M&F ScheduleCFC# Compressed Fibre Cement Lining Type -
Refer M&F ScheduleConc# Concrete Slab Type -
Refer M&F Schedule & Structural DocumentationCP Capping - Refer M&F ScheduleCpd J# Cupboard Joinery TypeD.# Door Number - Refer Door ScheduleD-# Detail Number - Refer Detail DrawingsDB# Double Brick Solid Wall Type -
Refer M&F Schedule & Structural DocDBC# Double Brick Cavity Wall Type -
Refer M&F Schedule & Structural DocumentationDP Downpipe -
Refer M&F Schedule & Hydraulic DocumentationDPC Damp Proof CourseDSB Distribution Switchboard -
Refer Electrical DocumentationEA Equal AngleF Refrigerator - Refer Appliances ScheduleFFL Finished Floor LevelFL Flashing - Refer M&F ScheduleFSC FasciaFW Floor WasteGD Grated Drain - Refer M&F ScheduleGPO General Purpose OutletGU Gutter -
Refer M&F Schedule & Hydraulic DocumentationGUG Gutter Guard - Refer M&F ScheduleHWU Hot Water Unit - Refer Mechanical DocumentationHR Handrail - Refer M&F ScheduleINS# Insulation Type - Refer M&F ScheduleKtn J# Kitchen Joinery TypeLI Lintel - Refer Structural DocumentationLWA Wet Area Laminate Wall Panelling -
Refer M&F ScheduleMR Mirror Type -
Refer M&F Schedule & Joinery DrawingsMSB Main Switchboard - Refer Electrical DocumentationNTS Not to ScaleOV Oven - Refer Appliances ScheduleP Pantry - Refer Joinery DrawingsP# Paint Finish type - Refer M&F SchedulePB# Plasterboard Lining Type - Refer M&F SchedulePBWA Wet Area Plasterboard Lining - Refer M&F SchedulePU Purlin - Refer Structural DrawingsPWD Person with a DisabilityRB# Roof Beam - Refer Structural DrawingsRH Range Hood -
Refer Appliances Schedule & Mech DocumentationRR Roof Rafter - Refer Structural DrawingsRRV Rotary Roof Ventilator - Refer M&F ScheduleRS# Roof Sheeting - Refer M&F ScheduleSB Splashback - Refer Joinery ScheduleSC# Steel Column Type -
Refer M&F Schedule & Structural DocumentationSCR# Screen Type - Refer M&F ScheduleSHR ShowerSHSC Shower Screen - Refer M&F Schedule and
Plumbing ScheduleSHST Shower Seat - Refer Plumbing ScheduleSHS Square Hollow SectionS Sink - Refer Plumbing ScheduleSM Shower Mixer - Refer Plumbing ScheduleSOP Set Out PointSS Stainless SteelTC# Timber Column - Refer M&F ScheduleTGSI Tactile Ground Surface Indicators -
Refer M&F ScheduleTS# Timber Stud Wall Type -
Refer M&F Schedule & Structural DocumentationVF# Vinyl Flooring - Refer M&F ScheduleW.## Window Number - Refer Window ScheduleWC# Toilet / Water Closet - Refer Plumbing ScheduleWPM Water Proof MembraneNote that 'M&F Schedule' refers to the Architectural Materials &Finishes Schedule.
ConsultantsArchitectureBark Design ArchitectsPO Box 1355 Noosa Heads, QLD Australia 4567Ph (07) 5471 0340 Fax (07) 5471 [email protected]
Note that the Architectural Documentation is tobe read in conjunction with the Consultantdocumentation as prepared by:
Landscape ArchitecturePenny SpiersPlace Design Group131 Robertson Street Fortitude Valley, QLDAustralia 4006Ph (07) 3852 [email protected]
Structural EngineeringPeter IdeWestera PartnersLevel 3, 33 Longland Street Newstead, QLDAustralia 4006Ph (07) 3852 [email protected]
Civil EngineeringJared HillWestera PartnersLevel 3, 33 Longland Street Newstead, QLDAustralia 4006Ph (07) 3852 [email protected]
Geotechnical InvestigationPeter ElkingtonPrecise GeotechnicalSuite 7/14 Fremantle Street Burleigh Heads,QLD Australia 4220Ph (07) 3852 [email protected]
Electrical Engineering & LightingCraig LittletonWebb Australia GroupCapital One Complex, Suite 13A/9 Capital PlaceBirtinya, QLD 4571Ph (07) 5438 8800 [email protected]
Mechanical EngineeringAlastair CarrWebb Australia GroupCapital One Complex, Suite 13A/9 Capital PlaceBirtinya, QLD 4571Ph (07) 5438 8800 [email protected]
Hydraulic & Wet Fire EngineeringTerry McKendryMRP HydraulicsPO Box 646 Cotton Tree, QLD 4558Ph (07) 3846 4379 [email protected]
Dry Fire EngineeringKevin Yui-Fire EngineersPO Box 968 Toowong DC, QLD 4066Ph 0450 188 189 [email protected]
Building CertifierRick BeardwoodCertis1/19 Finchley Street Milton, QLD Australia 4064Ph (07) 3144 [email protected]
Energy EfficiencyAndy VoCertis Energy1/19 Finchley Street Milton, QLD Australia 4064Ph 0428 399 710 [email protected]
Quantity SurveyorColin BrienRider Levett BucknallLevel 13, 10 Eagle Street Brisbane, QLDAustralia 4000Ph (07) 3009 6933 [email protected]
Town PlanningJames StottViva Property GroupSuite 2, The Green House, 183 WickhamTerrace Spring Hill, QLD Australia 4000Ph (07) 3831 [email protected]
Site SurveyAndrew HayesStatewide Survey GroupUnit 3/123 Link Road Victoria Point, QLDAustralia 4165Ph 1300 362 [email protected]
General Notes
1. Use Figured Dimensions in preference to scaling;2. All Dimensions & Site Levels are to be verified & checked on siteprior to construction commencing;3. All Works are to comply with all relevant Australian Standards,NCC Regulations, the Building Act 1975 & all other StatutoryProvisions as required;4. Any discrepancies within Contract, Consultancy &/or SchedulingDocumentation & on site conditions are to be referred to Bark DesignPty Ltd;5. Refer Geotechnical Engineers Report/Documentation for allearthworks, footing, slab, articulation joints to brickwork and retainingwall details;6. Moisture resistant linings to wet 'areas' in accordance to BCA;7. Lift-off hinges to W.C doors of PWD bathrooms;8. Smoke detection and alarm system in accordance with currentBCA (Qld) Edition. Smoke alarms shall comply with AS 3786 and beconnected to mains power (AS 3000);9. Termite Protection: Any chemical treatment barriers of relevantareas to be in accordance with BCA and AS3660.1 and other partsthereof shall be installed by a licensed pest control operator andauthorised by the manufacturer.10. Generally provide physical barriers, caps and Termimesh(orapproved equivalent) as applicable in accordance with BCA andAS3660.1;11. Member sizing, Bracing and Structural Details are not validwithout suitable certification from an Engineer, or as documented andcertified by project Structural Engineer;12. Refer to manufacturers' written advice, specifications and detailsfor installation of all propriety item or systems.13. Fire Resistance Levels of materials and all other requirements ofI-Fire Engineer's 'Fire Engineering Report' are to be met.14. The Insulation R values and slip rating values as listed in theMaterials & Finishes Schedule are to be met.15. The glass U values, SHGC and all other requirements of CertisEnergy's 'DTS Report' are to be met.16. All light switches to be located 1050mm above FFL.17. All GPOs to be located at either 300mm or 1050mm above FFL,unless otherwise noted on the Joinery Elevations.18. All door hardware to be located at 1050mm above FFL.19. All Bathroom walls to have adequate reinforcement included tomeet the requirements of Element 6 of the Liveable Housing DesignGuidelines.20. Units 29, 30, 33, 34, 37 & 38 are to comply with the GoldStandard of the Liveable Housing Design Guidelines 2017. Referpages 36 - 41.21. This Architectural Documentation is to be read in conjunction withall other Consultant's Documentation, inlcuding (but not limitied to)the Fire Engineering Report, Building Approval, Plumbing Approval,QFES Compliance Advice Report, Section J Energy EfficiencyReport, Geotechnical Report, Stormwater Management Report,Safety in Design Report, Architectural Materials & Finishes Scheduleand Architectural Specification.22. Taping, overlapping and the correct application of sarking andinsulation is to comply with Section J1.2(a)(iii), J1.2(b)(iv), J1.2(c),J3.6(b) & J3.6(c) of the NCC for Class 2 Dwellings.
Drawing No.A00.01
A01.01
A01.02
A02.01
A02.02
A02.03
A02.04
A02.05
A02.06
A03.01
A03.02
A03.03
A03.04
A03.05
A06.01
A06.02
A07.01
A08.01
A09.01
A10.01
A10.02
A10.03
A12.01
A12.02
A12.03
Cover Sheet
Existing Survey & Demolition Plan
Site Plan
Ground Floor Set Out Plan
Deleted
Ground Floor General Arrangement Plan
First Floor General Arrangement Plan
Roof Plan - Option A
Roof Plan - Option B
Building 1 Plans, Sections & Elevations
Building 2 Plans, Sections & Elevations
Building 3 & 4 Typical Plans, Sections & Elevations
Building 5 Plans, Sections & Elevations
Building 6 & 7 Plans, Sections & Elevations
Typical Unit Section Details
Typical Communal Area Section Details
Plan Details
Window Schedule
Door Schedule & Door Hardware
Stair & Walkway 1
Stair & Walkway 2 & 3
Stair & Walkway 2 & 3
PWD Joinery Elevations
Typical Unit & Hub Joinery Elevations
Joinery, Plumbing, Appliances & Signage Schedules
Reference Plans
Site Information
Planning InformationAddress: 17-21 Garfield Road, Woodbridge Qld 4114Lot & Plan: Lot 1 on RP160517Site Coverage: 37.5%Local Authority: Logan City CouncilZoning: Low-Medium Density Residential - Townhouse Precinct
Garfield Road
Pine Drive
Railw
ay Parade
Pine DriveG
arde
n A
venu
e
Stubbs Road
Station Road
Woodridge
Train Station
Drawing List
Existing Dwellings
Proposed GroundFloor Dwellings
Proposed FirstFloor Dwellings
24x Studio Units
6x One Bedroom Units
1x Office
1x Indoor Hub
1x Outdoor Hub
10x One Bedroom Units
Units 1-24
Units 29, 30, 33, 34, 37 & 38
*Units 25 & 26
*Units 41 & 42
Units 27, 28, 31, 32, 35, 36, 39, 40, 43, 44
Class 3
Class 2
Class 5
Class 5
Class 10a
Class 2
C/OV
C/OV
C/OV
C/OV
F
F
F
F
F
C/OV
C/OV
C/OV
C/OV
F
F
Sheet A03.01 Sheet A03.05
Sheet A03.02
Sheet A03.03
Sheet A03.03
Sheet A03.04
Sheet A03.05
Unit 42IndoorHub
Unit 38
Unit 37
Unit 34
Unit 33
Unit 30
Unit 29
Unit 26Office
Unit 25Office
OutdoorHub
Unit 41IndoorHub
BUILDING1
BUILDING2
BUILDING3
BUILDING4
BUILDING5
BUILDING6
Sheet A10.01
F
Stair & Walkway 1
Stair & Walkway 3Sheet A10.03
Stair & Walkway 2Sheet A10.02
Pedestrian EntryBUILDING 7
Location Plan
Development Information
*Note that the Office and Indoor Hub have been designed to allow Units 25, 26, 41 & 42 to be converted into OneBedroom Units in the future.
CertificationNote that Building 2 & 3 are considered to be a'Unified Building' for Certification and FireEngineering Purposes.Note that Building 4 & 5 are considered to be a'Unified Building' for Certification and FireEngineering Purposes.
View from Pine DriveExisting Unit DevelopmentProposed Unit Development
Legend for Line TypesSite BoundarySetbackContourStructure Above
WaterElectricityTelecommunicationsSewerExisting FenceProposed FenceCivil and Landscape WorksExisting Works to be RetainedExisting Works to be Demolished
Structure Below
Grid Line1
Legend for Wall TypesDBC1 Double Brick Cavity WallBV1 Brick Veneer WallBW1 Blockwork Party Wall InternalBW2 Blockwork Party Wall ExternalTS1/TS2 Timber Stud Walls as notedTS3 Double Timber Stud Framed WallDB1 Double Brick WallBRS3 Hit & Miss Brick Screen within DB1BRS1 Hit & Miss Brick ScreenBRS2 Solid Brick ScreenBW3 Blockwork Upstand WallBal# Balustrade / HR Handrail as noted
-First Floor Reference Plan
1:200
-Location Plan
1:2000
-Ground Floor Reference Plan
1:200
D
A 28.09.17 Preliminary 60% DD Issue to Consultants.B 06.10.17 60% Design Development Issue to Client.C 01.12.17 Preliminary 100% DD Issue to Consultants - Location Plan, Site Information, General Notes & Image added. Drawing List & Legend Updated.
ND 15.12.17 100% DD Issue to Client - Contract Documentation.
1:2000, 1:200 @ A1
-
Rev Date Description Drawing TitleProject
Revision
Drawing No.
Project No.Notes
CD.A01.01
1709
Date
17 - 21 Garfield Road,Woodridge Qld 4114
December 2017
Department of Housing &Public WorksHHS HPW 2017 - 006
Logan Youth Foyer Existing Survey &Demolition Plan
07 5
471
0340
07 5
471
0343
0418
876
394
0412
127
904
info
@ba
rkde
sign
.com
.au
ww
w.b
arkd
esig
n.co
m.a
u
Tel
epho
neF
acsi
mile
Ste
ve G
uthr
ieLi
ndy
Atk
inE
mai
lW
eb
Bar
k D
esig
n A
rchi
tect
s
Que
ensl
and
A
ustr
alia
456
7P
O B
ox 1
355
Noo
sa H
eadsUse figured dimensions
in preference to scale. Alldimensions to be varifiedand checked on site.These designs,drawings,specifications and thecopyright thereof are theproperty of Bark DesignPty Ltd and must not beused, retained or copiedwithout the writtenauthority of Bark DesignPty Ltd. 3668 (SG)3664 (LA)
Registration No.Architects
RAIA Member 28409
Scale 1:200 @ A1
Contract Documentation - Not for Construction
Approved By: LA, SG
Drawn By: MR
37.44
37.74
38.60
39.20
39.41
39.62
39.73
37.38
37.70
38.24
38.52
39.13
39.35
39.54
38.78 39.1939.80 40.18
40.33
40.9141.37
SL37.49
SL38.10
SL38.55
SL38.82
SL38.43
SL39.31
37.99
38.87
37.37
37.99
38.22
38.51
39.13
39.35
39.53
40.02
38.9238.57
41.35
41.42
41.47
38.45
40.1338.65
39.54
39.30
SL39.49
SL39.67
36.84
37.21
38.10
38.37
39.14
Ridge45.84
38.58
40.65
BOLs 38.56
38.08
38.13
37.36
39.21
38.38
37.62
38.27
39.09
39.10
37.98
38.57
IL 38.39
IL 37.80 250
38.23
38.76
39.46
38.75 39.18 39.77 40.3241.00
41.35
SL39.59
SL39.09SL41.72
38.63
38.58
39.07
IO 38.60
IO 39.05
IO 39.03
38.66
39.08
39.18
38.36
38.56
38.58
38.61
38.6638.6538.67
38.38
38.47
38.78
38.79
39.12
39.18
39.54
38.47
38.61
38.57
38.60
38.9038.96
38.89
38.83
39.5039.1839.0038.67
37.00
37.50
38.00
38.50
39.00
39.50
39.50
39.75
40.00 40.25
40.50
40.7539.25
39.0038.75
38.50
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HWHW
RAMP 1:3
0LET
TER
BOXES
MSB
HW
HW
38.2038.24 38.3838.35 38.48 38.75 38.91 39.04 39.14 39.32 39.56 39.97 40.06 40.37 40.71 40.87 41.07 41.21 41.47
38.8638.9138.8138.5138.3838.27
38.29
38.37
38.45
38.50
38.55
38.08 38.25 38.36 38.65 38.83 38.92 39.02 39.23 39.45 39.91 39.97 40.25 40.61 40.78 40.98 41.13 41.34
39.13
38.97
38.8538.8638.8538.7338.5138.2938.17
39.02
39.09
38.35
38.51
38.39
37.85
37.86
61.02
61.03
38.07 38.24 38.36 38.64 38.81 38.90 38.99 39.20 39.45 39.88 39.94 40.22 40.59 40.75 40.95 41.10 41.32
38.8338.7038.5038.2738.14
66.02 66.03
66.01
66.01
63.27
63.27
66.0166.02
66.02
38.81
38.7938.81
67.24
67.3767.36
38.56
38.55
38.11
38.7838.81
38.71
38.38
38.03 38.06
38.77
38.75
38.7538.79
38.52
38.56
38.41
38.59
38.53
38.45
38.5338.46
38.1038.2037.8437.83
38.04
38.08
38.04
37.99
37.99
37.91
37.82
40.05
61.47
38.7338.74
38.7338.73
39.03
38.00
38.5938.28
38.73
38.04
38.560
38.77
39.21
39.79
39.10 39.1639.97
Existing access gate andfence to Unit 13 backyard
to be replaced andrelocated. Refer
LandscapeDocumentation
Existing accessgate and fence to
Unit 10 backyard tobe relocated.
Existing fenceand retainingwall to bedemolished.
Existingpathway to be
demolishedand relocated.
Existing paths to bedemolished to make wayfor new drivewayconnection.
Existing paths to bedemolished to make wayfor new drivewayconnection.
Existing garden and gardenedging to be demolished tomake way for new drivewayconnection and pathways.
Existing trees to beretained. Refer
LandscapeDocumentation.
Neighbour's colorbondfence to be removed andreinstated on top of newblockwork retaining wall.
Refer LandscapeDocumentation.
Landscaped area to berectified after installation
and connection of newservices. Refer Consultants
Documentation.
Existing Road edgeto be retained inorder to retainadequate space forexisting tree roots.Refer CivilDocumentation.
Portion of ExistingDriveway to bedemolished and re-instated to allow forservices connectionsto new development.Refer to ConsultantDocumentation.
Existing retaining wall togarden bed to remain and isnot to be compromised bynew works.
Existing timber fence toremain.
Neighbour's existing wirefence to be demolished andreplaced with timber fenceon retaining wall.Refer LandscapeDocumentation
Existing fence,pedestrian andvehicle gate toremain.
Existing timberfence to remain.
ExistingUnit 10
FFL 38.620
ExistingUnit 9
FFL 38.620
ExistingUnit 6
FFL 38.550
ExistingUnit 1
FFL 38.450
ExistingUnit 13
FFL 39.200
ExistingUnit 14
FFL 39.200
ExistingUnit 2
FFL 38.450Adaptable Unit
ExistingUnit 22
FFL 38.870
ExistingUnit 21
FFL 38.870
ExistingUnit 18
FFL 39.250
ExistingUnit 17
FFL 39.250
ExistingUnit 5
FFL 38.550Bin
Existing CarPort 2
ExistingAdaptable Car
ParkExisting Car
Port 1
Store
39.10
38.570
38.25
Existing road to bewidened.
Refer CivilDocumentation.
Existing trees tobe demolished.
Refer LandscapeDocumentation.
Lot 2 onRP 103392
Lot 2 onRP 200350
P I N E D R I V E
G A R F
I E L D
R O A
D
Lot 1 onRP 160517
90°15'62|272
152°15'
67|822
332°16'97|023
ExistingDriveway
ExistingDriveway
Lot CP onSP 185691
242°17
'
55|01
D
A Preliminary 60% DD Issue to Consultants.28.09.1706.10.17 60% Design Development Issue to Client. More trees demolished, road widening shown, more of driveway to be demolished, two existing gates to be
relocated - as per Consultant documents. Notes added.B
Preliminary 100% DD Issue to Consultants - Section of existing driveway to be demolished adjusted based on required services locations. Siteinformation and road names added.
CN
01.12.17
15.12.17 100% DD Issue to Client - Contract Documentation.D
-
Rev Date Description Drawing TitleProject
Revision
Drawing No.
Project No.Notes
CD.A01.02
1709
Date
17 - 21 Garfield Road,Woodridge Qld 4114
December 2017
Department of Housing &Public WorksHHS HPW 2017 - 006
Logan Youth Foyer Site Plan07
547
1 03
4007
547
1 03
4304
18 8
76 3
9404
12 1
27 9
04in
fo@
bark
desi
gn.c
om.a
uw
ww
.bar
kdes
ign.
com
.au
Tel
epho
neF
acsi
mile
Ste
ve G
uthr
ieLi
ndy
Atk
inE
mai
lW
eb
Bar
k D
esig
n A
rchi
tect
s
Que
ensl
and
A
ustr
alia
456
7P
O B
ox 1
355
Noo
sa H
eadsUse figured dimensions
in preference to scale. Alldimensions to be varifiedand checked on site.These designs,drawings,specifications and thecopyright thereof are theproperty of Bark DesignPty Ltd and must not beused, retained or copiedwithout the writtenauthority of Bark DesignPty Ltd. 3668 (SG)3664 (LA)
Registration No.Architects
RAIA Member 28409
Scale 1:200 @ A1
Contract Documentation - Not for Construction
Approved By: LA, SG
Drawn By: MR
39.75
40.00
40.25
40.50
40.7539.25
39.0038.75
38.50
37.44
37.74
38.60
39.20
39.41
39.62
39.73
37.38
37.70
38.24
38.52
39.13
39.35
39.54
38.78 39.1939.80 40.18
40.33
40.9141.37
SL37.49
SL38.10
SL38.55
SL38.82
SL38.43
SL39.31
37.99
38.87
37.37
37.99
38.22
38.51
39.13
39.35
39.53
40.02
38.9238.57
41.35
41.42
41.47
38.45
40.1338.65
39.54
39.30
SL39.49
SL39.67
36.84
37.21
38.10
38.37
38.58
40.65
BOLs 38.56
38.08
38.13
37.36
39.21
38.38
37.62
38.27
39.09
39.10
37.98
38.57
IL 38.39
IL 37.80 250
38.23
38.76
39.46
38.75 39.18 39.77 40.3241.00
41.35
SL39.59
SL39.09SL41.72
38.63
38.58
39.07
IO 38.60
IO 39.05
IO 39.03
38.66
39.08
39.18
38.36
38.56
38.58
38.61
38.6638.65
38.38
38.47
38.78
38.79
39.12
39.18
39.54
38.47
38.61
38.57
38.60
38.9038.96
38.89
38.83
39.0038.67
37.00
37.50
38.00
38.50
39.00
39.50
39.50
Two StoreyWeatherboard Dwelling
Tiled Roof
Two StoreyWeatherboard Dwelling
Tiled Roof
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HW
HWHW
RAMP 1:3
0LET
TER
BOXES
MSB
HW
HW
38.2038.24 38.3838.35 38.48 38.75 38.91 39.04 39.14 39.32 39.56 39.97 40.06 40.37 40.71 40.87 41.07 41.21 41.47
38.8638.9138.8138.5138.3838.27
38.29
38.37
38.45
38.50
38.55
38.08 38.25 38.36 38.65 38.83 38.92 39.02 39.23 39.45 39.91 39.97 40.25 40.61 40.78 40.98 41.13 41.34
39.13
38.97
38.8538.8638.8538.7338.5138.2938.17
39.02
39.09
38.35
38.51
38.39
37.85
37.86
61.02
61.03
38.07 38.24 38.36 38.64 38.81 38.90 38.99 39.20 39.45 39.88 39.94 40.22 40.59 40.75 40.95 41.10 41.32
38.8338.7038.5038.2738.14
66.02 66.03
66.01
66.01
63.27
63.27
66.0166.02
66.02
38.81
38.7938.81
67.24
67.3767.36
38.56
38.55
38.11
38.7838.81
38.71
38.38
38.03 38.06
38.77
38.75
38.7538.79
38.52
38.56
38.41
38.59
38.53
38.45
38.5338.46
38.1038.2037.8437.83
38.04
38.08
38.04
37.99
37.99
37.91
37.82
61.47
38.7338.74
38.7338.73
39.03
38.00
38.5938.28
38.73
38.04
38.560
38.77
39.21
39.79
Shed
Two StoreyWeatherboard Dwelling
Tiled Roof
Shed
C/OV
C/OV
C/OV
C/OV
F
F
F
F
F
C/OV
C/OV
C/OV
C/OV
F
F
38.00
38.25
39.25
38.75
38.25
37.75
37.25
90°15'62|272
ExistingUnit 10
FFL 38.620
ExistingUnit 9
FFL 38.620
ExistingUnit 6
FFL 38.550
ExistingUnit 1
FFL 38.450
ExistingUnit 13
FFL 39.200
ExistingUnit 14
FFL 39.200
ExistingUnit 2
FFL 38.450Adaptable Unit
ExistingUnit 22
FFL 38.870
ExistingUnit 21
FFL 38.870
ExistingUnit 18
FFL 39.250
ExistingUnit 17
FFL 39.250
ExistingUnit 5
FFL 38.550Bin
Existing CarPort 2
ExistingAdaptable Car
ParkExisting Car
Port 1
Store
TerraceFFL 39.350
CommunalTerrace
FFL 38.850
Unit 42Indoor HubFFL 38.850
VF1
Unit 38FFL 39.370
VF1
Unit 37FFL 39.370
VF1
Unit 34FFL 39.800
VF1Unit 33
FFL 39.800VF1
Unit 30FFL 39.230
VF1Unit 29FFL 39.230
VF1Unit 26Office
FFL 39.300VF1
Unit 25Office
FFL 39.300VF1
Outdoor HubFFL 38.980
Refer to LandscapeDocumentation
TerraceFFL 39.350
TerraceFFL 39.800
TerraceFFL 39.800Terrace
FFL 39.230Terrace
FFL 39.230Terrace
FFL 39.300
Unit 41IndoorHub
BUILDING 1
BUILDING 2
BUILDING 3
BUILDING 4
BUILDING 5
BUILDING 6
New Driveway and Car Park
ASPTRefer to Civil
Documentation forSpecification & Levels
152°15'
67|822
332°16'97|023
Crown of Road
Crown
of Road
Edge of
Bitume
n
Edge of
Bitume
n
Back of
Kerb
Back of
KerbCon
crete P
athway
Concret
e Pathw
ay
38.570
One StoreyBrick Dwelling
Iron Roof
Crown of Road
Crown
of Road
Edge of
Bitume
n
Edge of
Bitume
n
Back of
Kerb
Back of
KerbCon
crete P
athway
Concret
e Pathw
ay
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
TerraceFFL 39.300
Lot 1 onRP 160517
Lot 2 onRP 103392
Lot 2 onRP 200350
16
17
Crossover &Vehicle Entry
ConcreteRefer to Civil
Documentation
P I N E D R I V E
G A R F
I E L D
R O A
D
New Footpath
ExistingCrossover &Vehicle Entry
Proposed RoadWideningRefer Civil
New Footpath
Walkw
ay 2
Walkw
ay 3
Walkw
ay 1
90°15'62|272
152°15'
67|822
332°16'97|023
ExistingDriveway
ExistingDriveway
Lot CP onSP 185691
242°17
'
55|01
F
New Driveway /Half Court Basketball
ConcreteRefer to Civil & Landscape
Documentation
2x PWDCar BaysConcrete
Vegetated SwaleRefer to Civil & LandscapeDocumentation
ReinstatedDriveway &
PathwayConcrete
Refer to Civil &Landscape
Documentation
Existing Road EdgeRefer to Civil Documentation
BUILDING 7Pedestrian Entry
FFL 39.500Refer to Landscape
Documentation
New FenceRefer to andscapeDocumentation
Retaining WallRefer to andscapeDocumentation
Existing Fencerelocated on top of
New Retaining WallRefer to Landscape
Documentation
Retained Treeson NE corner of Verge. Allother trees are new.Refer to LandscapeDocumentation
New FenceRefer to andscape
Documentation
K
D 04.10.17 Preliminary Issue to Landscape Architect - basic Civil elements added, walkways and columns updated.Preliminary Issue to Consultants - basic Civil elements added, walkways and columns updated, Landscape base revised.E 04.10.17
06.10.17 60% Design Development Issue to Client. Screens added to underside of stairs. Unit 33, 34, 37 & 38 Terraces now flush with internal FFL.F
NClient Meeting - Hallway widened to 1200mm in Units 33, 34, 37 & 38.02.11.17G
15.11.17H DHPW Feedback Issue to Consultants - Hallway widened to 1200mm in Units 33, 34, 37 & 38. Clothesline to Indoor Hub removed. AC to Indoor Hubremoved. Some BRS1 (hit & miss brick screen) changed to BRS3 (solid brick screen). BW4 added where 'Art Wall' is to be located on west wall of Units42 & 44. Materiality of front fence adjusted. Landscape CAD base updated. Pine Drive Kerb adjusted.
J 01.12.17 Preliminary 100% DD Issue to Consultants - Civil base updated. Section of existing driveway to be re-instated adjusted based on required serviceslocations. Unit 29 & 30 changed from PWD Studio Apartments to One Bedroom Units. All Unit Bathrooms re-arranged to include a separate Laundry tub.
15.12.17 100% DD Issue to Client - Contract Documentation.K
-
Rev Date Description Drawing TitleProject
Revision
Drawing No.
Project No.Notes
CD.A02.01
1709
Date
17 - 21 Garfield Road,Woodridge Qld 4114
December 2017
Department of Housing &Public WorksHHS HPW 2017 - 006
Logan Youth Foyer Ground Floor Set OutPlan
07 5
471
0340
07 5
471
0343
0418
876
394
0412
127
904
info
@ba
rkde
sign
.com
.au
ww
w.b
arkd
esig
n.co
m.a
u
Tel
epho
neF
acsi
mile
Ste
ve G
uthr
ieLi
ndy
Atk
inE
mai
lW
eb
Bar
k D
esig
n A
rchi
tect
s
Que
ensl
and
A
ustr
alia
456
7P
O B
ox 1
355
Noo
sa H
eadsUse figured dimensions
in preference to scale. Alldimensions to be varifiedand checked on site.These designs,drawings,specifications and thecopyright thereof are theproperty of Bark DesignPty Ltd and must not beused, retained or copiedwithout the writtenauthority of Bark DesignPty Ltd. 3668 (SG)3664 (LA)
Registration No.Architects
RAIA Member 28409
Scale 1:100 @ A1
Contract Documentation - Not for Construction
Approved By: LA, SG
Drawn By: MR
W29
D26
W21 D
17
W23
W22
W24
D21 W26
W28
W27
W25
D22
W19
W20
D16
D07
W14
W13
W12
W15
D11 W17
W18
W16
D12
D01
W38
D36
W47
W46
D37
D10
D08D09
D15
D13D14
W43
D39
C/OV
C/OV
13,600
4,925
4,995
5,480
4,925
4,995
3,880
4,925
4,995
2,278
5,200
10,200
3,600
10,200
2000
12,220
7,815
12,220
5,590
6,480
4,000
12,220
16,300
12,220
2,000
10,200
3,600
10,200
1,200
10,000
2,000
2,000
9,015
12,220
10,200
2,850
2,90
0
3,90
0
3,90
04,600
2,300
3,000
6,000
1,700
4,100
1,500
11,235
10,035
200
7,050
2,750
1,200
2,800
2,020600
1,780
10,200
3,110 1,200 3,110
230
500
7,420
3,000 445
760
1,000
4,200
280
+39,800
+39,800
+38,980
+38,850
+39,370
+39,300
+39,230
+39,230
+39,300+3
9,300
+38,850
+39,370 +39
,370
+39,110
+39,150
+38,700
+38,600
+38,850
+39,490
+39,590
+39,060
+39,230
+39,800
+39,50
0
4m Road Setback
5.5m Clear Width
C/OV
C/OV
W04
W03
W02
D04
F
F
F
F
F
C/OV
C/OV
C/OV
C/OV
F
F
D19D18
D20
D25D24
D23
D03
W30 D27
W32
W31
W33
D31
W44
W45
D40
MeetingRoom
VF1
BathVF1
BedVF1
BathVF1
TerraceFFL 39.370
CommunalTerraceFFL 38.850
Unit 42Indoor Hub
51m2FFL 38.850
VF1
Unit 3851m2
FFL 39.370VF1
Unit 3751m2
FFL 39.370VF1
Unit 3451m2
FFL 39.800VF1
Unit 3351m2
FFL 39.800VF1Unit 30
51m2FFL 39.230
VF1Unit 29
51m2FFL 39.230
VF1
Unit 26Office
51m2FFL 39.300
VF1
Unit 25Office
51m2FFL 39.300
VF1
Outdoor Hub62.5m2
FFL 38.980Refer to Landscape
Documentation
AC
Awn A
bove
Awn A
bove
Awn
Above
Awn A
bove
Awn A
bove
Awn A
bove
Awn A
bove
Awn A
bove
BalconyAbove
BalconyAbove
BalconyAbove Balcony
Above
BalconyAbove
Balcony Above
TerraceFFL 39.370
TerraceFFL 39.800
TerraceFFL 39.800
CBD
CBD
CBD
CBD
CBD
CBD
BathVF1
BedVF1
BathVF1
BedVF1
BathVF1
BedVF1
TerraceFFL 39.230
TerraceFFL 39.230
P
P Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
TerraceFFL 39.300
BedVF1
BathVF1
MeetingVF1
BedVF1
P
P
PP
PP
Unit 41Indoor Hub
51m2FFL 38.850
VF1
BalconyAbove
BalconyAbove
Stair 1Conc 2
Stair 2Conc 2
Stair 3Conc 2
Walkw
ay 2
Walkw
ay 3
Walkw
ay 1
ExistingUnit 13FFL 39.200
ExistingUnit 14FFL 39.200
ExistingUnit 10FFL 38.620
ExistingUnit 9
FFL 38.620
1:201:20
1:20.5
1:22
1:22
1:22
1:23
1:20
1:20
1:20
1:201:20
1:23
1:22
WM
PP
WM
DR
GrassedAreaRefer to
LandscapeDocumentation
DSB
BUILDING 1BUILDING 2
BUILDING 3
BUILDING 4
BUILDING 5
BUILDING 6
BUILDING 7Pedestrian
EntryFFL 39.300
LdryVF1
LdryVF1
WM
Walkw
ay Above
WM
WM
WM
WM
CBD
WM
CBD
PPP
LdryVF1
LdryVF1
LdryVF1
LdryVF1
S
S
S
S
S
SS
S
S
S
S
S
S
S
SS
S
S
S
S
SHR
SHR
SHR
SHR
SHR
SHR
SHR
SHR
S
S
Walkw
ay Above
Walkw
ay Abo
ve
Flush
Bins
Bins
Bins
Bins
Bins
Bins
1
1
A
A
F
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
B
B
F
F
G
G
K
K
L
L
H
H
J
J
M
M
N
C
C
D
D
E
E
W11
W10
W01
W05
D05
W07
W08
W09
W06
D06
W35
W37
W36
W34
D32
D29D28
D30
D35
D34
D33
W39
W42
D38
D41
D02
W41
W40
AP1
AP2
2.0m Side Setback
1.5m Side Setback
2.5m Side Setback
2.5m Side Setback
2.0m Side Setback
1.5m Side Setback
K
Preliminary Issue to Consultants - Stair treads adjusted. Columns adjusted to match Structural documentation. Walkway moved over 100mm as clouded.Handrails added to stairs.
24.10.17E
N
F Client Meeting - Hallway widened to 1200mm in Units 33, 34, 37 & 38.02.11.17G DHPW Feedback Issue to Consultants - Hallway widened to 1200mm in Units 33, 34, 37 & 38, internal walls adjusted to suit. Clothesline to Indoor Hub
removed. AC to Indoor Hub removed. Some BRS1 (hit & miss brick screen) changed to BRS3 (solid brick screen). BW4 added where 'Art Wall' is to belocated on west wall of Units 42 & 44. PWD vanities reduced in depth.
10.11.17
H Preliminary Issue to Hydraulic Engineer - Shower head locations clarified.13.11.17J Preliminary 100% Issue to Consultants - General notes added. Additional dimensions added. Unit 29 & 30 changed from PWD Studio Apartments to One
Bedroom Units. All Unit Bathrooms re-arranged to include a separate Laundry tub. Door & Window numbers updated.01.12.17
15.12.17 100% DD Issue to Client - Contract Documentation.K
-
Rev Date Description Drawing TitleProject
Revision
Drawing No.
Project No.Notes
CD.A02.03
1709
Date
17 - 21 Garfield Road,Woodridge Qld 4114
December 2017
Department of Housing &Public WorksHHS HPW 2017 - 006
Logan Youth Foyer Ground Floor GeneralArrangement Plan
07 5
471
0340
07 5
471
0343
0418
876
394
0412
127
904
info
@ba
rkde
sign
.com
.au
ww
w.b
arkd
esig
n.co
m.a
u
Tel
epho
neF
acsi
mile
Ste
ve G
uthr
ieLi
ndy
Atk
inE
mai
lW
eb
Bar
k D
esig
n A
rchi
tect
s
Que
ensl
and
A
ustr
alia
456
7P
O B
ox 1
355
Noo
sa H
eadsUse figured dimensions
in preference to scale. Alldimensions to be varifiedand checked on site.These designs,drawings,specifications and thecopyright thereof are theproperty of Bark DesignPty Ltd and must not beused, retained or copiedwithout the writtenauthority of Bark DesignPty Ltd. 3668 (SG)3664 (LA)
Registration No.Architects
RAIA Member 28409
Scale 1:100 @ A1
Contract Documentation - Not for Construction
Approved By: LA, SG
Drawn By: MR
SL38.82
SL38.43
38.92
38.57
38.58
40.65
39.09
39.10
IL 38.39
IL 37.80 25038.63
38.58
IO 39.03
38.6638.65
38.89
38.83
39.0038.67
HW
HW
HW
HW
38.8638.91
38.29
38.37
38.85
38.8638.85
39.09
38.51
38.39
37.85
37.86
61.02
61.03
38.83
66.03
66.01
66.01
63.27
63.27
66.01
66.02
66.02
67.24
67.3767.36
38.56
38.03 38.06
38.59
38.53
38.45
38.1038.20
37.8437.83
38.04
38.08
38.04
37.99
37.99
37.91
37.82
38.0038.04
38.560
W29
D26
W21 D
17
W23
W22
W24
D21 W26
W28
W27
W25
D22
W19
W20
D16
D07
W14
W13
W12
W15
D11 W17
W18
W16
D12
D01
W38
D36
W47
W46
D37
D10
D08D09
D15
D13D14
W43
D39
C/OV
C/OV
+39,800
+39,800
+38,980
+38,850
+39,370
+39,300
+39,800
+39,800
+39,370
+38,850 +38
,850
+39,230
+39,230
+39,300+3
9,300
+38,850
+39,370 +39
,370
+39,230
+39,370
+39,110
+39,150
+38,700
+38,600
+38,850
+39,490
+39,590
+39,060
+39,230
+39,800
+39,50
0
4m Road Setback
5.5m Clear Width
C/OV
C/OV
W04
W03
W02
D04
Kitchen
BBQ
F
F
F
F
F
C/OV
C/OV
C/OV
C/OV
F
F
D19D18
D20
D25D24
D23
D03
W30 D27
W32
W31
W33
D31
W44
W45
D40
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16PWD
17PWD
Vehicle Entry
MeetingRoom
VF1
BathVF1
BedVF1
BathVF1
TerraceFFL 39.370
CommunalTerraceFFL 38.850
Unit 42Indoor Hub
51m2FFL 38.850
VF1
Unit 3851m2
FFL 39.370VF1
Unit 3751m2
FFL 39.370VF1
Unit 3451m2
FFL 39.800VF1
Unit 3351m2
FFL 39.800VF1Unit 30
51m2FFL 39.230
VF1Unit 29
51m2FFL 39.230
VF1
Unit 26Office
51m2FFL 39.300
VF1
Unit 25Office
51m2FFL 39.300
VF1
Outdoor Hub62.5m2
FFL 38.980Refer to Landscape
Documentation
New Drivewayand Car Park
ASPTRefer to Civil
Documentation forSpecification & Levels
AC
Awn A
bove
Awn A
bove
Awn
Above
Awn A
bove
Awn A
bove
Awn A
bove
Awn A
bove
Awn A
bove
BalconyAbove
BalconyAbove
BalconyAbove Balcony
Above
BalconyAbove
Balcony Above
TerraceFFL 39.370CD
CDCD
CDCD
CD
TerraceFFL 39.800
TerraceFFL 39.800
CBD
CBD
CBD
CBD
CBD
CBD
BathVF1
BedVF1
BathVF1
BedVF1
BathVF1
BedVF1
TerraceFFL 39.230
TerraceFFL 39.230
P
P Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
TerraceFFL 39.300
BedVF1
BathVF1
MeetingVF1
LibraryVF1
DiningVF1
LoungeVF1
KitchenVF1
BedVF1
P
P
PP
PP
Unit 41Indoor Hub
51m2FFL 38.850
VF1
CrossoverRefer to Civil
Documentation
BalconyAbove
BalconyAbove
Stair 1Conc 2
Stair 2Conc 2
Stair 3Conc 2
152°15'
67|822
332°16'97|023
90°15'62|272
38.570
New P
ath
Refer
to Land
scape
Docum
entatio
n
ExistingDriveway
New Footpath
Walkw
ay 2
Walkw
ay 3
Walkw
ay 1
ExistingUnit 13FFL 39.200
ExistingUnit 14FFL 39.200
ExistingUnit 10FFL 38.620
ExistingUnit 9
FFL 38.620
1:201:20
1:20.5
1:22
1:22
1:22
1:23
1:20
1:20
1:20
1:201:20
1:23
1:22
WM
PP
WM
DR
SharedZone
Existing CarPort 2
Existing CarPort 1
New Footpath
GrassedAreaRefer to
LandscapeDocumentation
DSB
BUILDING 1BUILDING 2
BUILDING 3
BUILDING 4
BUILDING 5
BUILDING 6
LdryVF1
LdryVF1
WM
Walkw
ay Above
WM
WM
WM
WM
CBD
WM
CBD
PPP
LdryVF1
LdryVF1
LdryVF1
LdryVF1
S
S
S
S
S
SS
S
S
S
S
S
S
S
SS
S
S
S
S
SHR
SHR
SHR
SHR
SHR
SHR
SHR
SHR
S
S
Walkw
ay Above
Walkw
ay Abo
ve
GD GD
GDGD
GD
GDGD G
D
GD GD
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Bins
Bins
Bins
Bins
Bins
Bins
1
1
A
A
F
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
B
B
F
F
G
G
K
K
L
L
H
H
J
J
M
M
N
C
C
D
D
E
E
W11
W10
W01
W05
D05
W07
W08
W09
W06
D06
W35
W37
W36
W34
D32
D29D28
D30
D35
D34
D33
W39
W42
D38
D41
D02
W41
W40
AP1
AP2
New Driveway & HalfCourt Basketball /
PWD Parking BaysConcrete
Refer to Civil & LandscapeDocumentation
ReinstatedDrivewayConcrete to matchExistingRefer to Civil &LandscapeDocumentation
UndergroundDetention Tank
Refer to CivilDocumentation
Vegetated SwaleRefer to Civil &LandscapeDocumentation
LetterboxesRefer to LandscapeDocumentation
BUILDING 7Pedestrian Entry8.5m2 FFL 39.500Refer to Landscape Documentation
Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
ArbourRefer to Landscape
Documentation
Max 1:33RampedLanding
Max 1:33RampedLanding
Max 1
:33
Ramp
ed
Landin
g
Max 1
:33
Ramp
ed
Landin
g
Max 1:33RampedLanding
Open BicycleStore Under
StairsRefer Materials &
Finishes Schedule
Open
Bicycle
Store U
nder
Stairs
Refer
Materi
als &
Finish
es Sch
edule
Open
Bicycle
Store
Under
Stairs
Refer
Materi
als &
Finish
es Sch
edule
HWU U
nder
Bench
HWU U
nder
Bench
HWU U
nder
Bench
HWU U
nder
Bench
HWU U
nder
Bench
HWU U
nder
Bench H
WU Un
der
Bench
HWU U
nder
Bench
IrrigationController
Refer to LandscapeDocumentation
2.0m Side Setback
1.5m Side Setback
2.5m Side Setback
2.5m Side Setback
2.0m Side Setback
1.5m Side Setback
L
06.10.17 60% Design Development Issue to Client. Screens to underside of stairs added.FPreliminary Issue to Consultants - Stair treads adjusted. Walkway moved over 100mm as clouded.24.10.17G
NClient Meeting - Hallway widened to 1200mm in Units 33, 34, 37 & 38.02.11.17H
J DHPW Feedback Issue to Consultants - Hallway widened to 1200mm in Units 33, 34, 37 & 38. Clothesline to Indoor Hub removed. AC to Indoor Hubremoved. Some BRS1 (hit & miss brick screen) changed to BRS3 (solid brick screen). BW4 added where 'Art Wall' is to be located on west wall of Units42 & 44. Materiality of front fence adjusted. Landscape CAD base updated. Pine Drive Kerb adjusted.
10.11.17
K Preliminary 100% Issue to Consultants - General notes added. Civil base updated. Unit 29 & 30 changed from PWD Studio Apartments to One BedroomUnits. All Unit Bathrooms re-arranged to include a separate Laundry tub. Door & Window numbers updated.
01.12.17
15.12.17 100% DD Issue to Client - Contract Documentation.L
-
Rev Date Description Drawing TitleProject
Revision
Drawing No.
Project No.Notes
CD.A02.04
1709
Date
17 - 21 Garfield Road,Woodridge Qld 4114
December 2017
Department of Housing &Public WorksHHS HPW 2017 - 006
Logan Youth Foyer First Floor GeneralArrangement Plan
07 5
471
0340
07 5
471
0343
0418
876
394
0412
127
904
info
@ba
rkde
sign
.com
.au
ww
w.b
arkd
esig
n.co
m.a
u
Tel
epho
neF
acsi
mile
Ste
ve G
uthr
ieLi
ndy
Atk
inE
mai
lW
eb
Bar
k D
esig
n A
rchi
tect
s
Que
ensl
and
A
ustr
alia
456
7P
O B
ox 1
355
Noo
sa H
eadsUse figured dimensions
in preference to scale. Alldimensions to be varifiedand checked on site.These designs,drawings,specifications and thecopyright thereof are theproperty of Bark DesignPty Ltd and must not beused, retained or copiedwithout the writtenauthority of Bark DesignPty Ltd. 3668 (SG)3664 (LA)
Registration No.Architects
RAIA Member 28409
Scale 1:100 @ A1
Contract Documentation - Not for Construction
Approved By: LA, SG
Drawn By: MR
D65
W75 D
66
D73
D57
D81
W60
D53
W61
D54
D55D56
D42
W51
D45
W52
D46
D43
D44
D49
D48
D47
W84 D
74
W87
D77
D79D80
+42,800
+42,800
+42,780
+42,210
+41,830
+42,350
+42,210
+41,830
+42,230 +42
,230
+41,850
+41,850
+42,300+4
2,300
+42,370
+42,370
+42,280
4m Road Setback
2.0m Side Setback
1.5m Side Setback
2.5m Side Setback
F
C/OV
C/OV
W74
W68
D59
D60
D63D64
W67
D75
D76
W90
W83
W77
D67
D68
D71D72
W76
D51
D52
W63
W56
W48
W49
F
F
F
F
FF
F
FF
C/OV
C/OV
C/OV
C/OV
C/OV
C/OV
C/OV
C/OV
W66 D
58
W69
D61
W71
W73
W72
W78
D69 W80
W82
W81
W65
W64
W59
W62
W57
W58
1
1
A
A
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
B
B
F
F
G
G
K
K
L
L
H
H
J
J
M
M
N
C
C
D
D
E
ERoof Over
Outdoor HubRefer Roof Plan
152°15'
67|822
332°16'97|023
Roof Over EntryStructure
Refer Roof Plan
90°15'62|272
Balcony11.9m2
FFL 41.830Conc1
Cover
ed Wa
lkway
3
Conc2
Unit 4451m2
FFL 41.850VF1
Unit 4351m2
FFL 41.850VF1
Unit 4051m2
FFL 42.370VF1
Unit 3951m2
FFL 42.370VF1
Unit 3651m2
FFL 42.800VF1
Unit 3551m2
FFL 42.800VF1
Unit 3251m2
FFL 42.230VF1
Unit 3151m2
FFL 42.230VF1
Unit 2851m2
FFL 42.300VF1
Unit 2751m2
FFL 42.300VF1
20mm
Step 20
mm
Step 20m
m
Step 20
mm
Step
20mm
Step 20
mm
Step
20mm
Step20m
m
Step
20mm
Step20m
m
Step
BedVF1
Bath / LdryVF1
Bath /LdryVF1
BedVF1
Bath /
Ldry
VF1
BedVF1
Bath / LdryVF1
BedVF1
Bath / LdryVF1
BedVF1
Bath / LdryVF1
BedVF1
Bath /LdryVF1
Bath /LdryVF1
CBD
CBD
CBD
CBD
CBD
CBD
CBD
CBD
CBD
CBD
PP
PP
PP
BedVF1
BedVF1
PP
PP
PP
Balcony12.9m2
FFL 41.830Conc1
BedVF1
Bath / LdryVF1
Bath /LdryVF1
BedVF1
PP
20mm
Step
Cover
ed Wa
lkway
2
Conc2Co
vered
Walkw
ay 1
Conc1
Stair 1Conc 2
Stair 2Conc 2
Stair 3Conc 2
Roof Above
Aw
n Above
Roof AboveRoof Above
Roof Above
Roof Above
Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
Aw
n Above
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
Roof A
bove
20mmStep
20mmStep
20mmStep
20mmStep
20mmStep
P
P
P
Stair 4Conc 2
Stair 5Conc 2
WM
BUILDING1
BUILDING2
BUILDING 3
BUILDING4
BUILDING5
BUILDING 6
BUILDING 7
WM
WM
WM
WM
WM
WM
WM
WM
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S
WM
SHR
SHR
SHR
SHR
SHR
SHR
SHR
SHR
SHR
SHR
Balcony11.9m2
FFL 41.830Conc1
Balcony12.9m2
FFL 41.830Conc1
Balcony11.9m2
FFL 41.830Conc1
Balcony12.9m2
FFL 41.830Conc1Balcony
11.9m2FFL 41.830
Conc1
Balcony12.9m2
FFL 41.830Conc1
Balcony11.9m2
FFL 41.830Conc1
Balcony12.9m2
FFL 41.830Conc1
RRV
Above
RRV
Above
RRV
Above
RRV
Above
RRV
Above
RRV
Above
RRV
Above
RRV
Above
RRV
Above
RRV
Above
Bal3
Bal3
Bal3
Bal3
Bal3 Ba
l3
Bal3
Bal3
SC
R1 S
CR
1
SC
R1
SC
R1
SCR1 S
CR1
SCR1
SCR1
Bal3
Bal3
Bal3
Bal3
Bal3
Bal3
W70
D62
W91
W92
W86
W89
W88
D78
W85
W79
D70
D50
W50
W53
W54
W55
HWU U
nder
Bench HW
U Unde
r
Bench
HWU U
nder
Bench
HWU U
nder
Bench
HWU U
nder
Bench
HWU U
nder
Bench
HWU U
nder
BenchH
WU Un
der
Bench
HWU U
nder
Bench
HWU U
nder
Bench
2.5m Side Setback
2.0m Side Setback
1.5m Side Setback
L
Preliminary Issue to Consultants - Elevated walkways adjusted to suit ground floor walkways. Columns adjusted to match Structural documentation.Stairs shifted back 400mm. Steel columns to external walls added. W47, W56 & W61 moved over slightly. W70 & W71 locations corrected. Handrailsadded to walkways.
24.10.17F
NClient MeetingG 02.11.17DHPW Feedback Issue to Consultants - Some BRS1 (hit & miss brick screen) changed to BRS3 (solid brick screen). 100mm gap added between BW3upstand and BW2 party wall to allow drainage to east balconies. BW4 added where 'Art Wall' is to be located on west wall of Units 42 & 44.
10.11.17H
J Preliminary Issue to Hydraulic Engineer - Shower head locations clarified.13.11.17K Preliminary 100% Issue to Consultants - General notes added. All Unit Bathrooms re-arranged to include a separate Laundry tub. Door & Window
numbers updated.01.12.17
15.12.17 100% DD Issue to Client - Contract Documentation.L
-
Rev Date Description Drawing TitleProject
Revision
Drawing No.
Project No.Notes
CD.A02.05
1709
Date
17 - 21 Garfield Road,Woodridge Qld 4114
December 2017
Department of Housing &Public WorksHHS HPW 2017 - 006
Logan Youth Foyer Roof Plan - Option A07
547
1 03
4007
547
1 03
4304
18 8
76 3
9404
12 1
27 9
04in
fo@
bark
desi
gn.c
om.a
uw
ww
.bar
kdes
ign.
com
.au
Tel
epho
neF
acsi
mile
Ste
ve G
uthr
ieLi
ndy
Atk
inE
mai
lW
eb
Bar
k D
esig
n A
rchi
tect
s
Que
ensl
and
A
ustr
alia
456
7P
O B
ox 1
355
Noo
sa H
eadsUse figured dimensions
in preference to scale. Alldimensions to be varifiedand checked on site.These designs,drawings,specifications and thecopyright thereof are theproperty of Bark DesignPty Ltd and must not beused, retained or copiedwithout the writtenauthority of Bark DesignPty Ltd. 3668 (SG)3664 (LA)
Registration No.Architects
RAIA Member 28409
Scale 1:100 @ A1
Contract Documentation - Not for Construction
Approved By: LA, SG
Drawn By: MR
4m Road Setback
2.0m Side Setback
1.5m Side Setback
2.5m Side Setback
1
1
A
A
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
B
B
F
F
G
G
K
K
L
L
H
H
J
J
M
M
N
C
C
D
D
E
E
RS1 5° CustomOrb RoofSheeting
RS1 5° CustomOrb RoofSheeting
RS1 5° CustomOrb RoofSheeting
RS1 5° CustomOrb RoofSheeting
RS1 5° CustomOrb RoofSheeting RS1 5° Custom
Orb RoofSheeting
RS1 5° CustomOrb RoofSheeting
RS1 5° CustomOrb RoofSheeting
RS1 5° CustomOrb RoofSheeting
RS1 5° CustomOrb RoofSheeting
RS2 5° CustomOrb RoofSheeting
RS2 2° CustomOrb RoofSheeting
Awn Below
Awn Below
Awn Below
Awn Below
Awn Below
Awn Below
Awn Below
Awn Below
Awn Below
Awn Below
Awn Be
low
Awn Be
low Awn Be
low
Awn Be
low
Awn Be
low
Awn Be
low
Awn
Below
Awn
Below
200mmStep
200mmStep
200mmStep
200mmStep
200mmStep
DP
DP
DP
DP
DP
DP
DPDP
DP
DP
DP
DP
DP
DP
DP
DPDP
DP
DP
DP
DP
DP DP
DP
870mmStep
750mmStep
200mmStep
200mmStep
BUILDING 1 BUILDING 2
BUILDING 3
BUILDING 4
BUILDING 5BUILDING 6
BUILDING 7
BRS3 Wallbelow
RRV
BRS3 Wallbelow
BRS3 Wallbelow
Top of brick veneer
wall below
Top of brickveneer wall
below
Top of brick veneer
wall below
GU
GU
GU GU
GU
GU
GU
GU
GU
GU
GU
GU
GU
GU
GU
BRS3 W
all
below
RRV
RRV
RRV
RRV
RRV
RRV
RRV
RRV
RRV
BW2 Wall Below
BW2 Wall Below
BW2 W
all
Below
BW2 Wall Below
BRS3 W
all
Below
GU
BW2 W
all
Below
BRS3 W
all
Below
BRS3 W
all
Below
GU
2.5m Side Setback
2.0m Side Setback
1.5m Side Setback
Notes
Note that two roof options have been provided in order to allowTenderer's to separate the costs for both options. The two options areas follows:- Roof Option A on A02.05: This option incorporates a roof to the entirityof all three first floor walkways with all columns shown on plansincluded.- Roof Option B on A02.06: This option does not incorporate a roof tothe first floor walkways. A portion of roof is included which extends overthe first floor unit entries as shown, which is to include the necessarycolumns.
Note that documentation throughout based on 'Roof Option A'.
Refer to Hydraulic Documentation for further information regarding roofdrainage.
Refer to A03 Drawing series for further information regarding roofdimensions.
Note that location of aerials to be approved by Architect prior toinstallation.
H
A 18.09.17 Preliminary Issue to ConsultantsB 28.09.17 Preliminary 60% DD Issue to Consultants.
Preliminary Issue to Consultants - Roof over elevated walkways adjusted. Pedestrian entry roof adjusted to match Landscape base.C 04.10.1706.10.17 60% Design Development Issue to Client.D24.10.17 Preliminary Issue to Consultants - Gutter and Downpipe locations shown. Roof over walkway adjusted slightly.E N
DHPW Feedback Issue to Consultants - Some BRS1 (hit and miss) changed to BRS3 (solid brick wall). Covered Walkway roof stepdowns noted.10.11.17F
SEPARABLE PORTION - Roof Option A
G Preliminary 100% Issue to Consultants - Building extent below rooves shown dashed. General Notes added.01.12.1715.12.17 100% DD Issue to Client - Contract Documentation.H
-
Rev Date Description Drawing TitleProject
Revision
Drawing No.
Project No.Notes
CD.A03.01
1709
Date
17 - 21 Garfield Road,Woodridge Qld 4114
December 2017
Department of Housing &Public WorksHHS HPW 2017 - 006
Logan Youth Foyer Building 1 Plans,Sections & Elevations
07 5
471
0340
07 5
471
0343
0418
876
394
0412
127
904
info
@ba
rkde
sign
.com
.au
ww
w.b
arkd
esig
n.co
m.a
u
Tel
epho
neF
acsi
mile
Ste
ve G
uthr
ieLi
ndy
Atk
inE
mai
lW
eb
Bar
k D
esig
n A
rchi
tect
s
Que
ensl
and
A
ustr
alia
456
7P
O B
ox 1
355
Noo
sa H
eadsUse figured dimensions
in preference to scale. Alldimensions to be varifiedand checked on site.These designs,drawings,specifications and thecopyright thereof are theproperty of Bark DesignPty Ltd and must not beused, retained or copiedwithout the writtenauthority of Bark DesignPty Ltd. 3668 (SG)3664 (LA)
Registration No.Architects
RAIA Member 28409
Scale 1:100 @ A1
Contract Documentation - Not for Construction
Approved By: LA, SG
Drawn By: MR
39.80
W12
D01
+39,300
+39,300
01
02
03
04 Bth J1A12.01
01
02 Ktn J1A12.01
01
02
Cpd J1A12.01
W04
W03
W02
D04
F
C/OV
D03
MeetingRoom
VF1
Unit 26Office
51m2FFL 39.300
VF1
Unit 25Office
51m2FFL 39.300
VF1
Awn Above
BalconyAbove
Aw
n A
bove
Aw
n A
bove
TerraceFFL 39.300
AC
BathVF1
Aw
n A
bove
Aw
n A
bove
Refer to LandscapeDocumentation for
Terrace PavingLayout
TerraceFFL 39.300
Refer to LandscapeDocumentation for
Terrace PavingLayoutBalconyAbove
P
Roof Above
Refer to A10.01 forStair and Walkway1 Documentation.
Note: VF1 tocontinue underKitchen Joinery
WMS
SSHR
Stair Above
1
A
2 3
B B
C C
W11
W10
W01
W05D05
W07
W08
W09
W06 D06
D02
1,78
02,
220
12,2
203,
797
4,925 4,995
2801,4752,170230850270
8502302,1701,395280
10,800600
4,00
010
,000
2,90
023
050
1,57
01,
055
920
560
1,81
087
52,
650
280
2,55
035
028
03,
415
110
3,40
011
02,
405
280
280 3,300 110 6,230 280
5,0051905,00510355102,650765850
2301907508503,405685350
270 2,890 90 1,675 350 4,655 270
10,0
001,
500
750
280
2,65
01,
590
2,65
074
01,
810
280
600
280
9,44
028
04,
425
5,01
5
7523
0
HWUUnder Sink
Ktn J1
BW2
BP1
DBC1
Bth J1
SHST
Cpd J1
RHAbove
BW1
BRS3
DBC1
BW2
BP1
BRS1
DBC1
BP1
Plumbing Stackwithin Cpd
GD
GD
DBC1BRS3
1 in 33 fallto landingaway fromentry door.
DP DP
DP
DP
DP
WC2
CD
SM
Irrigation ControllerExact Location TBCon SiteRefer LandscapeDocumentation
AA03.01
AA03.01
CA03.01
CA03.01
BA03.01
BA03.01
DA03.01
DA03.01
NorthA03.01
SouthA03.01
WestA03.01
EastA03.01
D42
W51D45
W52 D46
D43
D44
D49
D48
D47
D-33A07.01
12,2
203,
797
4,00
010
,000
2,90
094
523
011
01,
810
680
2,65
01,
590
2,65
028
02,
550
350
785
160
260
1,89
011
03,
220
110
4,29
411
63,
694
600
7523
0
350
750
116
3,69
460
011
03,
220
110
1,89
026
0
2,10
01,
120
2,10
01,
120
100
50110
5014
0
1,02
51,
250
1.450
4,100
1,350
4,050
3,64
076
0
+42,300
+42,300
W56
W48
W49
F
F
C/OV
C/OV
1
A
2 3
B B
C C
BalconyFFL 42.280
12.9m2, Conc1
Unit 2851m2
FFL 42.300VF1
Unit 2751m2
FFL 42.300VF1
20mmStep
20mmStep
BalconyFFL 42.280
11.9m2, Conc1
BedVF1
Bath /LdryVF1
Bath /LdryVF1
BedVF1
P
P
Awn Above
Aw
n A
bove
Aw
n A
bove
Aw
n A
bove
Aw
n A
bove
Refer to A10.01 forStair and Walkway1 Documentation.
Note: VF1 tocontinue under
Ktn Joinery.
WM
S S
S
S
SSWM
SHR
SHR
SM
SM
RRVAbove
RRVAbove
W50
W53
W54
W55
4,925 4,995
250 1,425 2,170 230 850350
850 230 2,170 1,425 250
85910,200900
3,555 110 1,000 350 1,000 110 3,5556002,955
1,50
010
,000
4,40
01,
100
270
2,65
01,
600
2,65
068
01,
870
280
600
5,0051905,0051,027600 4,005 920
80 190 230850 3,925 600
3,555 1,655 1,900
2,955600
4,665 350 4,665
AA03.01
AA03.01
CA03.01
CA03.01
BA03.01
BA03.01
DA03.01
DA03.01
NorthA03.01
SouthA03.01
WestA03.01
EastA03.01
HWUUnder Sink
HWUUnder Sink
Ktn J3
SB
RHAbove
CpdJ2
WC
Bth J3BW1
Cpd J2
Ktn J3 SB
RHAbove
Bth J3
BW2
BP1
BW1
DBC1
BW2
Bal1
Bal2
Bal1
Bal2
BW3 Upstand
BW3 Upstand
BP1
BRS1
CD
DBC1
BP1
BRS3
BRS3
Bal4100mm gap inBW3 fordrainage.
SC1
SC1
SC1
SC1
SC1
SC1DP DP
DP
DPDPWC
SHSC
SHSC
CD
3,00
02,
400
2,40
060
02,
050
W07
W53
W54
W08W09
W55
FFL39.300
FFL42.300
CFC1
DBC1
BV1
BW2
BW3BW3
BW2
B AFRS1 5° Slope
Bal 2
BW3Upstand
Bal1
Awn
SC1
RS1 5°Slope
BP1
BP1
RRV
CFC1 SheetJoins Dashed
BRS3 BRS1
Bal 2
Bal1
GU
DP
RRV
FSC
SC1AwnAwn
Awn Awn
GU
3,00
02,
400
2,40
060
02,
050
D06 D05
D45D46
FFL39.300
FFL42.300
CFC1
DBC1
BW3 BW3
CFC1
DBC1
3 2 1
SC1
Bal 2
Bal 1
BRS3
RS1 5°Slope
Awn
SC1
CFC1 Horizontal SheetJoin across entirelength of wall to line upwith door head
CFC1 VerticalSheet Joins Dashed
BPBP
Awn
RRV
FSC
BW2
Bal 1
Bal2
3,00
02,
050
2,40
060
0
W11 W10W01
D42
W56
FFL 39.300
FFL 42.300
CFC1
BV1
DBC1
BW2
DBC1
BV1
1 2 3RS1 5°Slope
Bal3
BRS3
RS1 5°Slope
BP1
RRV
CFC1 VerticalSheet JoinsDashed
RRV
FSC FSC
DP
GU DP
GUDP
behind
SC1
Awn
Awn
3,00
02,
400
2,40
060
02,
050
D01
W04
W50W48
D49
W49
W03 D04 W02
FFL39.300
FFL42.300
CFC1
BV1
DBC1
BW2
BW2
BW2
A B
RS1 5°Slope
SC1
RS1 5°Slope
BW3Upstand
Bal4
BRS1
BP1
HR
BP1
RRV
CFC1 Vertical SheetJoins Dashed
RRV
AwnAwn
AwnAwn
SC1
SC1 Bal3
DP Stair 1
DP
GUGU
SC1
GU
D-01A06.01
D-02A06.01
D-03A06.01
D-04A06.01
D-05A06.01
D-06A06.01
D-14A06.01
D-15A06.01
D-35A06.02
D-28A06.02
3,00
02,
400
2,40
060
02,
050
1,02
0
670
D01W07D05
D03
D45
D43D44
D49
D02
FFL39.300
FFL42.300
Unit 27 Bed
Unit 25MeetingRoom
Bath
PB3
PB3 PB1
PB1
PBWA
PBWA
BW2
BW2
BW2
BW2Bath/Ldry
CPD
CPD
A BF
TS1
RS1 5°Slope
Bal1BW3
Upstand
RRV
BW2
Stair 1
Conc1
RS1
RS1 5°Slope
Bal3
Note: Min.2100mmhigh atPitchingPoint
Note: Min.2400mm high at
Pitching Point
HR
DP
GU
DBC1
BV1DP
GU
DBC1
TS2
TS2
Bal3HR
TS2
TS2
RRV
PB1
CPD
SB Bal3
TS1
D-07A06.01
D-08A06.013
,000
2,40
02,
400
600
2,05
0
W11W11
W07
W10
W04
W53
D42W56
W50
FFL 39.300
FFL 42.300
Unit 28 Unit 27
Unit 26Office
Unit 25Office
Awn
Awn
PB1
PB2
SBSB
PB1
PB2
PB1
SB
PB1
3 2 1
BP1
RS1 5°Slope
TS1
BRS3
DBC1
TS1
RRVRS1 5°
Slope
DBC1
BV1BV1
Awn
AC
FSCFSC
BW1
PB3
Awn
D-09A06.01
3,00
02,
400
2,40
060
02,
050
1,02
0
670
D01
W10
D06D03
D46D48 D47
FFL39.300
FFL42.300
Unit 28BedBath/Ldry
Unit 26Office
Awn
AwnPBWA PB1
PB3
PB3 PB1
BW2
BW2
BW2
BW3 BW3
CPD
PB1
B A
RS1 5°Slope
RRV
Bal2
Bal1
BW3Upstand
BRS1
BP1
CD
SC1
BRS1
RRVNote: Min.2400mm high atPitching Point
FSC
CDBP1
Bal2Bal1
GU
DP
DBC1
BV1
GU
DBC1
TS1
DP
WMUnderBench
D-10A06.01
3,00
02,
400
2,40
060
02,
050
W11W10
D03
W01
D42
D44
W56
W49
D04
FFL39.300
FFL42.300
Awn
Unit 28Bed
Unit 27Bed
Unit 26Office
MeetingRoom
Awn
PB1 PB1 PB1 PB1
PB1PB1
PB2PB2
PB1
3 2 1
RS1 5°Slope
RS1 5°Slope
DBC1
BRS3
BP1
TS1
BV1
DBC1
BW1
BV1
TS2
TS2
TS2
Awn
TS1
AwnPB3
CPD
PB1
2500
H PB
2500H PB 250
0H P
B2
2500H PB2
2500H PB2
2800H P1
2800H P1
Awn
Aw
nA
wn
Aw
nA
wn
Rob
e
MeetingRoom
Unit 26Office
Unit 25Office
Terrace
Bath
TerraceKtnJoinery
2400HPB
BHD
AC
AC
AC
2400HPB2 BHD
Undersideof Balcony
Undersideof Balcony
RakingPB25°
Raking PB25°
RakingPB25°
RakingPB25°
RakingCFC2
5°
RakingCFC2
5°
RakingPB25°
Raking PB25°
Awn
Aw
nA
wn
Aw
nA
wn
Rob
e
Rob
e
Balcony
Unit 28
Unit 27
Balcony
Bed
Bath / Ldry
Bed
Bath / Ldry
2400HPB2 BHD
2400HPB2 BHD
KtnJoinery
2400HPB2 BHD
KtnJoinery
2400HPB2 BHD
Undersideof Roof
RRVVent
RRVVent
Building 1 - Ground Floor Plan1:100
Building 1 - First Floor Plan1:100
Building 1 - East Elevation1:100A03.01
Building 1 - North Elevation1:100A03.01
Building 1 - South Elevation1:100A03.01
Building 1 - West Elevation1:100A03.01
Building 1 - Section A1:100A03.01
Building 1 - Section B1:100A03.01
Building 1 - Section C1:100A03.01
Building 1 - Section D1:100A03.01
Building 1 - Ground Floor RCP1:100
Building 1 - First Floor RCP1:100
A 26.09.17 Preliminary Issue to ConsultantsB 28.09.17 Preliminary 60% DD Issue to Consultants.
G
06.10.17 60% Design Development Issue to Client. A/C units shown on RCP. Plumbing stack moved to cupboard. Grid lines shown on elevations and sections.C
NE DHPW Feedback DD Issue to Consultants - Comcork flooring changed to Vinyl. PWD vanity drawers reduced in depth. 100mm gap added betweenBW3 upstand and BW2 party wall to allow drainage to east balconies.
10.11.1719.10.17 Preliminary issue to Electrical & Mechanical Consultants.D
Preliminary 100% DD Issue to Consultants - References updated. Down pipes noted. All Bathrooms re-arranged to include a separate Laundry tub.Door & Window numbers updated. Joinery numbers updated.
A02.01
A02.01 A02.04
A02.04
F 01.12.17
15.12.17 100% DD Issue to Client - Contract Documentation.G
-
Rev Date Description Drawing TitleProject
Revision
Drawing No.
Project No.Notes
CD.A03.02
1709
Date
17 - 21 Garfield Road,Woodridge Qld 4114
December 2017
Department of Housing &Public WorksHHS HPW 2017 - 006
Logan Youth Foyer Building 2 Plans,Sections & Elevations
07 5
471
0340
07 5
471
0343
0418
876
394
0412
127
904
info
@ba
rkde
sign
.com
.au
ww
w.b
arkd
esig
n.co
m.a
u
Tel
epho
neF
acsi
mile
Ste
ve G
uthr
ieLi
ndy
Atk
inE
mai
lW
eb
Bar
k D
esig
n A
rchi
tect
s
Que
ensl
and
A
ustr
alia
456
7P
O B
ox 1
355
Noo
sa H
eadsUse figured dimensions
in preference to scale. Alldimensions to be varifiedand checked on site.These designs,drawings,specifications and thecopyright thereof are theproperty of Bark DesignPty Ltd and must not beused, retained or copiedwithout the writtenauthority of Bark DesignPty Ltd. 3668 (SG)3664 (LA)
Registration No.Architects
RAIA Member 28409
Scale 1:100 @ A1
Contract Documentation - Not for Construction
Approved By: LA, SG
Drawn By: MR
40.33
W21
W23
W22
W19W20
D16
D07
W14
W13
W12
W15
D11
W17
W18
W16
D12
D10
D08
D09
D15
D13
D14
D-30A07.01
C/OV
+39,800
+39,230
+39,230
+39,230
C/OV
C/OV
F
F
FBedVF1
BathVF1
Unit 3051m2
FFL 39.230VF1
Unit 2951m2
FFL 39.230VF1
AwnAbove
Balcony Above
Balcony Above
BathVF1
TerraceFFL 39.230
Aw
n A
bove
P
BedVF1
TerraceFFL 39.230
Refer to LandscapeDocumentation for
Terrace PavingLayout
Refer to LandscapeDocumentation for
Terrace PavingLayout
Note: VF1 tocontinue under
Ktn Joinery.
Refer to A10.02& A10.03 for
Stair andWalkway 2 & 3Documentation.
P
WM
WM
P S
SS
SS
S
SHR
SHR
4 5 6
F F
G G
D-29A07.01
4,925 4,995
12,2
202,
900
10,0
001,
100
350
750
280
1,81
01,
150
2,65
01,
180
2,65
028
02,
550
350
280
2,10
011
03,
400
110
3,72
028
0
2302301,8102,7351904,7752302309,740230600
280 3,335 110 1,200350
1,200 110 3,335 280
4,18
0
600 10,200 600
230 1,445 2,170 230 85080 190 80
850 230 2,170 1,445 230280 4,645 350 4,645 280
6004,045
12,8
0035
075
028
02,
650
1,18
02,
650
3,24
01,
350
350
4,40
028
03,
720
110
3,40
011
02,
100
280
600
1,30
02,
100
3,12
060
02,
100
1,30
092
011
01,
070
2,5751106501101106501102,575
920
110
1,07
011
0
HWUUnderSink
HWUUnder Sink
Cpd J2
Ktn J2
WC
Bth J2
Bth J2
Cpd J2
Ktn J2
BW2
BW1
SB
PlumbingStack
within Cpd
PlumbingStack withinCpd
BP1
BRS3
DBC1
BW2
BP1
BRS1
BRS3
BP1
BRS3
BP1
1 in 33 fallto landingaway fromentry door.
DSB DP
DP DP
RHAboveSB
RHAbove
WC
SM
SM
SHSC
SHSC
DP
CD
CD
AA03.02
AA03.02
CA03.02
CA03.02
BA03.02
BA03.02
DA03.02
DA03.02
SouthA03.02
WestA03.02
NorthA03.02
EastA03.02
D57
W60D53
W61 D54
D55
D56
D-33A07.01
1,12
02,
100
+42,230
+42,230
C/OV
W68
W67
D51
D52
W63
F
F
F
C/OV
C/OV
W66
W65 W64
W59
W62
W57
W58
4 5 6
F F
G G
Balcony12.9m2
FFL 42.210Conc1
Unit 3251m2
FFL 42.230VF1
Unit 3151m2
FFL 42.230VF1
20mmStep
20mmStep
Balcony11.9m2
FFL 42.210Conc1
BedVF1
Bath / LdryVF1
BedVF1
Bath / LdryVF1
Aw
n A
bove
Aw
n A
bove
Refer to A10.02& A10.03 for
Stair andWalkway 2 & 3Documentation.
Note: VF1 tocontinue under
Ktn Joinery.
P
P
WM
WM
S S
S
S
SS
SHR
SHR
RRVAbove
RRVAbove
D50
W55
D-34A07.01
12,2
20
4,925 4,99590010,200900
600 230 1,445 2,170 230 85080 190 70
860 230 2,170 1,445 230 600260 4,665 350 4,665 260
2603,5551101,000350
1,0001103,555260
2,90
010
,000
1,10
035
075
034
01,
810
680
2,65
01,
600
2,65
027
02,
550
350
2,15
011
03,
220
110
4,29
411
62,
000
3,69
460
01,
120
2,10
0
350
750
270
2,65
01,
600
2,65
02,
830
116
4,29
411
03,
220
110
1,89
026
060
04,
400
3,69
460
0
2301,8101,65585023019080
9203,7758301,6551,00090030 1,000
100
AA03.02
AA03.02
CA03.02
CA03.02
BA03.02
BA03.02
DA03.02
DA03.02
SouthA03.02
WestA03.02
NorthA03.02
EastA03.02
HWUUnder Sink
HWUUnder Sink
Ktn J3
SB
RHAbove
Cpd J2
WCBth J3
Cpd J2
Ktn J3 SB
RHAbove
WCBth J3
BW2
BW1
BP1
DBC1
BW2
Bal1
Bal2
Bal1
Bal2
BW3 Up stand
BW3Upstand
BP1
BRS1CD
BRS3
BP1
BRS3
BP1
BRS3
Bal4
100mm gap inBW3 fordrainage.
SC1
SC1
SC1
SC1
SC1
SC1
DP DP
DP DP
SM
SM
CD
3,00
02,
400
600
2,05
02,
400
W62
W63
W17W18
FFL39.230
FFL42.230
CFC1
DBC1
BV1
BW2
BW3BW3
BW2
Stair 2
G FK
CFC1 SheetJoins Dashed
RS1 5°Slope
Bal 2
BW3Upstand
Bal1
SC1
RS1 5°Slope
BP1
BP1
RRV
BRS3 BRS1
Bal 2
Bal1
RRV
FSC
AwnAwn
Awn
HR
Bal3
BP1
BRS1
Bal3
SC1
HR
3,00
02,
400
2,40
060
02,
050
W16 W15
D53D54
D12 D11
FFL39.230
FFL42.230
CFC1
DBC1
BW3 BW3
CFC1
DBC1
6 5 4CFC1 VerticalSheet Joins Dashed
SC1
Bal 2
Bal 1
RS1 5°Slope
Awn
SC1
CFC1 Horizontal SheetJoin across entire
length of wall to line upwith door head
BP
BP
Awn
RRV
FSC
BW2
Bal 1
Bal2
Awn
Awn
Bal3HR
3,00
02,
050
2,40
060
0
D50 W65
W19
W64
W20D07
FFL39.230
FFL42.230
CFC1
BV1
DBC1
DBC1
BV1
DBC1
CFC1
4 5 6RS1 5°Slope
RS1 5°Slope
BP1
RRVRRV
FSC FSC
DP
GU DP
GU
DP
Awn
BW2
HR
Awn
Awn
DPSCR1
BRS3
Awn
Awn
3,00
02,
400
2,40
060
02,
050 W59
D57W58
W57
D16W14
W13W12
FFL39.230
FFL42.230
CFC1
BV1
DBC1
BW2
BW2
BW2
F K G
CFC1 Vertical SheetJoins Dashed
RS1 5°Slope
SC1
RS1 5°Slope
BW3Upstand
Bal4
BRS1
BP1
BP1
RRV RRV
AwnAwn
AwnAwn
DP
GUGU
SC1
SCR1
BRS3
GUDP
G
3,00
02,
400
2,40
060
02,
050
1,02
0
670
D11
W59W57
W58
W14W13
W12
FFL39.230
FFL42.230
Unit 29Living
Unit 31LivingBed
Bath/Ldry
Bath/Ldry
PB1
PBWA PB1
PB1
LWA
LWA
BedPBWA
F
RS1 5°Slope
RS1
Bal1
BW3Upstand
CD
Bal2
SC1
BRS3
Note: Pitching Pointdictated by CoveredWalkway 2 PitchingPoint.
BP
DBC1DP
BV1
GU CD
BP1
BRS1
TS2PB1
CPD
SB
C/OV
TS2SHSC
SHSC
TS1
D53
3,00
02,
400
2,40
060
02,
050
W62
D50W65
W20 D07
W17
FFL39.230
FFL42.230
Unit 29Unit 30
Unit 31Unit 32
PB1
PB2
PB1
PB2
SB SB
PB1
SCR1
SBSB
PB1
CPD
PB1 PB1CPD
PB1
CPD
PB1
CPD
PB1
CPD
6 5 4
RS1 5°Slope
TS1
DBC1
RRVRS1 5°
Slope
SC1
Bal3
Awn
Awn
AwnAwn
BW2
HR
RS1 5°Slope
Stair 2
Bal3
3,00
02,
400
2,40
060
02,
050
1,02
0
670
D54
D12
D55D56
D15 D13
FFL39.230
FFL42.230
Unit 30
Unit 32BedBath/Ldry
Bath
PB1
BW2
PBWA
BW2
BW2
PB3
PB3PBWA
BW3 BW3
CPD
Bed
CPDPB1MR
G F
RS1 5°Slope
RRV
Bal2
Bal1
BW3Upstand
BRS1
BP1CD
SC1
SC1
Awn
Awn
Note: Min.2100mm high
at PitchingPoint
SCR1