Connected Components Workbench
Task-based Quick Start
QS# CN06 – Connect to a PowerFlex 4-Class Drive using a 1203-USB and
Configure the Drive in the CCW
![Page 2: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/2.jpg)
Hardware & Software Versions Used to Develop This Quick Start
Connected Components Workbench (CCW) Release 1 software
PowerFlex 4 Drive
1203-USB
Prerequisite
CN05 Adding a PowerFlex 4-Class Drive to a CCW Project
![Page 3: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/3.jpg)
3 of 18
Connect to a PowerFlex 4 Drive using a 1203-USB Connection
This quick start will show you how to add 1203-USB to the CCW project to be able to connect to the PowerFlex 4 Drive added in quick start CN05.
1. Once you are on the PowerFlex 4 Device Configuration window, click on the add+ tab:
![Page 4: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/4.jpg)
4 of 18
2. Double-click on the 1203-USB:
3. Click on the 1203-USB tab added on the bottom:
![Page 5: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/5.jpg)
5 of 18
4. Before connecting to the Drive, you must install the 1203-USB drivers and configure new DF1
connection on RSLinx (refer to publication DRIVES-UM001B-EN-P). Click the Connect button:
![Page 6: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/6.jpg)
6 of 18
5. Expand the DF1 connections and look for the 01,AB DSI representing the 1203-USB, select it and
then click OK.
![Page 7: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/7.jpg)
7 of 18
6. Notice the green background around the drive in the Project organizer meaning that you are now
connected to the PowerFlex 4 using the 1203-USB. Click on the PowerFlex 4 drive tab:
![Page 8: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/8.jpg)
8 of 18
7. Select the Wizards as shown:
![Page 9: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/9.jpg)
9 of 18
8. Select the PowerFlex 4 Startup Wizard and then click Select.
9. The following screen will show. Click Next to skip this welcome screen:
![Page 10: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/10.jpg)
10 of 18
10. Click on Reset Parameters :
11. Click Yes and then click Next:
![Page 11: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/11.jpg)
11 of 18
12. In this quick start we will use the default Motor Data. Click Next:
![Page 12: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/12.jpg)
12 of 18
13. Select as shown and then click Next:
![Page 13: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/13.jpg)
13 of 18
14. To complete the Direction Test follow these steps:
a. Click to clear the present fault (F048) if showing.
b. Enter the desired reference. For this quick start we’ll use 30Hz and then click .
c. A speed reference acknowledgement window will appear to accept a parameter change.
Click Yes.
d. By now the motor should be rotating at reference speed. Verify that the motor direction of
rotation is correct and then select the Yes radio button.
e. You are done with the direction test. Click Next to continue.
![Page 14: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/14.jpg)
14 of 18
15. Select as shown and then click Next:
![Page 15: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/15.jpg)
15 of 18
16. Select Comm Port and then click Next:
![Page 16: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/16.jpg)
16 of 18
17. Set the Start Source to Comm Port to eventually set the frequency in Quick Start CN08 to some of
the Preset Freqs shown below. Select as shown and then click Next:
![Page 17: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/17.jpg)
17 of 18
18. Select as shown and then click Next:
![Page 18: Connected Components Workbench Task-based …staveb.ch/downloads/cn06-_connect-to-a-powerflex-4-class-drive-usi.pdfConnected Components Workbench (CCW) Release 1 software PowerFlex](https://reader031.fdocuments.us/reader031/viewer/2022022600/5b3ac0567f8b9a986e8b79a9/html5/thumbnails/18.jpg)
18 of 18
19. Click Finish:
20. Save the project by clicking and the following window will appear. Click Yes to upload the drive
parameters.