CONFIGURATION INSTRUCTIONS WCS3B-LS3** with SSI...

8
CONFIGURATION INSTRUCTIONS FACTORY AUTOMATION WCS3B-LS3** with SSI interface

Transcript of CONFIGURATION INSTRUCTIONS WCS3B-LS3** with SSI...

CONFIGURATION INSTRUCTIONS

FACTORY AUTOMATION

WCS3B-LS3**with SSI interface

Part.

No. x

xxxx

x / D

OCT-

1311

A / 0

9.02.2

012

Rhead WCS3B-LS3**

3

Date

of iss

ue: 0

9. feb

ruary

2012

Part N

o. xx

xxxx

Docu

ment

No. D

OCT-

1311

A

1 Configuration switch inside the reading head . . . . .41.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41.2 Changing ot the output code . . . . . . . . . . . . . . . . . . . . . . . . .51.3 Output of soiled optics warning . . . . . . . . . . . . . . . . . . . . . . 51.4 Re-assembly after configuration . . . . . . . . . . . . . . . . . . . . . . 5

2 Configuration switch on the integrated displaymodule (Reading head with option -D) . . . . . . . . . . .6

2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62.2 Configuration switch S1D on the display circuit board . . .7

Reading head WCS3B-LS3**Configuration switch inside the reading head

Date

of iss

ue: 0

9. feb

ruary

2012

Part N

o. xx

xxxx

Dcou

ment

No. D

OCT-

1311

A

1 Configuration switch inside the reading head1.1 General

The configuration of the reading head can be changed by the DIL switchS1, which is located inside the reading head. S1 is a DIP switch with 4 sin-gle switch positions.

figure 1.1: Position of the configuration switch S1To change the switches, the housing of the reading head must be opened.Therefore screw up the four housing screws from the bottom side.

S1

4

Reading head WCS3B-LS3**Configuration switch inside the reading head

Date

of iss

ue: 0

9. feb

ruary

2012

Part N

o. xx

xxxx

Docu

ment

No. D

OCT-

1311

A

1.2 Changing of the output code

Example:• Encoding has changed from Binary into Gray:

Change designation WCS3B-LS310 into WCS3B-311!

1.3 Output of soiled optics warningThe warning about soiled optics is transmit-ted in the bit 24 of the SSI protocol. The soi-ling indication bit is enabled by default(factory setting).

n = 0 or 1

1.4 Re-assembly after configurationFor re-assembly after the configuration, close the hosing and fix the fourscrews with a torque of 1.0 Nn.

Reading head type S1 Encoding1 2 3 4

WCS3B-LS310 ON OFF x x BinaryWCS3B-LS311 OFF OFF x x Gray

If the configuration of the reading head was changed, please change the type code on the reading head label, too.

Reading head type S1 soiling ind. bit1 2 3 4

WCS3B-LS31n x OFF x OFF enabledWCS3B-LS31n x OFF x ON disabled

The setting of the soiling indication bit is not mentioned on the reading head label.

Note

Note

5

Reading head WCS3B-LS3**Configuration switch on the integrated display mo-

Date

of iss

ue: 0

9. feb

ruary

2012

Part N

o. xx

xxxx

Dcou

ment

No. D

OCT-

1311

A

2 Configuration switch on the integrated display module(Reading head with option -D)

2.1 GeneralThe WCS3B reading head can be equipped (also later on, at factory) withan optional display module. This display shows during movement of thereading head the current position value and, if it happens, an error code. Ifthe reading head does not move for longer than 15 seconds, then the dis-play will show additional diagnostics data (see also WCS catalogue).For viewing the displayed values also in upright mounted position of thereading head, the orientation of the displayed values can be rotatedaround 180° by the DIP switch S1D on the display circuit board.

figure 2.1: Adaptation of the display to the reading head orientation

M12

M12

upright mounted code rail (orientation 0°)

suspensory mounted code rail (orientation 180°)

6

Reading head WCS3B-LS3**Configuration switch on the integrated display mo-

Date

of iss

ue: 0

9. feb

ruary

2012

Part N

o. xx

xxxx

Docu

ment

No. D

OCT-

1311

A

2.2 Configuration switch S1D on the display circuit board

figure 2.2: Positions of the configuration switches S1 and S1D

Displayorientation

S1D Description1 2

0° OFF OFF displayed values are readable at upright mounted code rail180° ON ON displayed values are readable at suspensory mounted code

rail

S1

S1D

7

Subject to modi�cationsCopyright PEPPERL+FUCHS • Printed in Germany

www.pepperl-fuchs.com

Worldwide HeadquartersPepperl+Fuchs GmbH68307 Mannheim · GermanyTel. +49 621 776-0E-mail: [email protected]