Conectores Pfisterer Sn Hv Connex en 2011

16
PFISTERER solutions for your network

description

Conectores SF6-aire y SF6-aceite

Transcript of Conectores Pfisterer Sn Hv Connex en 2011

Page 1: Conectores Pfisterer Sn Hv Connex en 2011

PFISTERERsolutions for your network

Page 2: Conectores Pfisterer Sn Hv Connex en 2011

History

1978: Introduction of MV-Connex, 24 kV - 36 kV - 52 kV

1988: HV-CONNEX Size 4, 72,5 kV

1994: HV-CONNEX Size 5S, 145 kV

1999: HV-CONNEX Size 6, 170 kV

2002: HV-CONNEX Size 6S, 245 kV

2006: Plug-In Outdoor Bushing Size 6, 170 kV

2007: Surge Arrester for HV CONNEX Size 4

Page 3: Conectores Pfisterer Sn Hv Connex en 2011

HV-CONNEXCable Termination Systemsfor high voltage networks

Page 4: Conectores Pfisterer Sn Hv Connex en 2011

Motivation: Dry TypeGIS / Transfomer compartment completely enclosed at

manufacturing site

Connection without expensive gas or oil works on-site

Quick Assembly

Works at the transformer and assembly of the cable termination are

completely independent

GIS or transformer compartment

Page 5: Conectores Pfisterer Sn Hv Connex en 2011

Size Classification

Max. Diameter over

conductor /

insulation

Cross Section *

IN

Um

50,4 mm / 75 mm

1600 mm²

2500A

72,5kV

Size 4

64,9 mm / 110,5mm

2500 mm²

2500A

170kV

Size 6

50,4 mm / 76 mm

1600 mm²

2500A

145kV

Size 5-S

64,9 mm / 110,5mm

2500 mm²

2500A

245kV

Size 6-S

*valid only, if values comply to max. diameter over insulation / max. diameter over conductor

Page 6: Conectores Pfisterer Sn Hv Connex en 2011

Socket- The heart of the system

Page 7: Conectores Pfisterer Sn Hv Connex en 2011

TransformerTesting: IEC 60137

Dimensions: EN 50299

Cable TerminationTesting: IEC 60840 bzw. IEC 62076

GISRoutine Test: IEC 62271-203

Type Test: IEC 60840 Iec 62076

Dimensions: IEC 62271-209

Page 8: Conectores Pfisterer Sn Hv Connex en 2011

Examples of Usage “Transformer”

Page 9: Conectores Pfisterer Sn Hv Connex en 2011

Further Transformer applications

HK Macau Siemens

Irkutsk Russia

Oberhasli Switzerland EBG

Page 10: Conectores Pfisterer Sn Hv Connex en 2011

Examples of Usage “GIS”

Page 11: Conectores Pfisterer Sn Hv Connex en 2011

HV - Cable Termination System – Application switchgear

Page 12: Conectores Pfisterer Sn Hv Connex en 2011

Pfisterer ConnexTerminales enchufables hasta 245 kV

Aplicaciónes de GIS

� Terminal enchufable Connex en seco� Terminal convencional

Page 13: Conectores Pfisterer Sn Hv Connex en 2011

Routine Tests

• Routine Test according to (EN50089 / DIN

EN 60137 / DIN EN 62271-203 / DIN EN

50089)

• Visual Examination

• Meausurements

• Material Test

• Temperature Test (-40°C – 110°C)

• Rated Power Frequency Voltage (460kV)

• Partial Discharge (< 5pC at 2*U0)

• Gas Tightness (Helium; < 4*10-7 bar cm³/s)

• Pressure Test (2*design pressure 1min)

• X-Ray Test

Page 14: Conectores Pfisterer Sn Hv Connex en 2011

Features of the Separable Connecting System

An interface for oil and gas insulated components

A complete connection system for cables, overhead lines and surge

arresters

Prefabricated and routine tested components

Quick and reliable assembly

Rapid and simple disconnection in the event of faults

Connection without expensive gas or oil works on-site

Works at the transformer and assembly of the cable termination are

independent of each other

Worldwide References several thousand HV accessories in use

worldwide tens of thousands for medium voltage

Page 15: Conectores Pfisterer Sn Hv Connex en 2011

HV Connex – Off Shore

Off Shore Version Optional

available

Page 16: Conectores Pfisterer Sn Hv Connex en 2011

Low Temperature Test

Accessories for temperatures down to -50°C

System Size 5-S

Connector / Socket / dummy plug / bushing

System Size 6 (test performed with limited values)

Connector / Socket / dummy plug

Accessories for temperature down to -25°C

Bushing Size 6