Conductor rail ULA power supply line selection

2
Conductor rail ULA power supply line selection FZ-SZ-ULA 032018 EN UNILIFT Sp. z o. o., sp. k. www.unilift.pl e-mail: [email protected] 1. Inquiry form 1. Line section 2. Covering flange 3. End feed 4. Current collector with connecting cable 5. Sliding hanger 6. Fixing hanger 7. Towing arm 8. Support arm with girder clips 9. End cap List of items: 1 2 3 4 5 5 6 8 7 9 Device characteristics Conductor rail power supply length: L = m Power supply parameters: AC DC Frequency: f = Hz Voltage: U = V Number of poles: phases + PE Device name Motor data Crane/device 1 Crane/device 2 Crane/device 3 Main lift drive Auxiliary lift drive Bridge drive Trolley drive Other Nominal current I [A] N cos φ N Duty cycle (% ED) Power consumption [kW] Nominal current I [A] N cos φ N Nominal current I [A] N cos φ N Power consumption [kW] Power consumption [kW] Duty cycle (% ED) Duty cycle (% ED)

Transcript of Conductor rail ULA power supply line selection

Conductor rail ULA power supply line selection

FZ

-SZ

-ULA

032018 E

N

UNILIFT Sp. z o. o., sp. k. www.unilift.pl e-mail: [email protected] 1.

Inquiry form

1. Line section

2. Covering flange

3. End feed

4. Current collector with connecting cable

5. Sliding hanger

6. Fixing hanger

7. Towing arm

8. Support arm with girder clips

9. End cap

List of items:

1

2

3 45

5

6

8

7

9

Device characteristics

Conductor rail power supply length: L = m

Power supply parameters: AC DC

Frequency: f = Hz

Voltage: U = V

Number of poles: phases + PE

Device name

Motor data

Crane/device 1 Crane/device 2 Crane/device 3

Main lift drive

Auxiliary lift drive

Bridge drive

Trolley drive

Oth

er

Nom

inal curr

ent

I [

A]

N

cos φ

N

Duty

cycle

(% E

D)

Pow

er

consum

ption

[kW

]

Nom

inal curr

ent

I [

A]

N

cos φ

N

Nom

inal curr

ent

I [

A]

N

cos φ

N

Pow

er

consum

ption

[kW

]

Pow

er

consum

ption

[kW

]

Duty

cycle

(% E

D)

Duty

cycle

(% E

D)

initiator:[email protected];wfState:distributed;wfType:email;workflowId:8dc4f4a9fd60a942a9479fe78ebdc582

Conductor rail ULA power supply line selection

FZ

-SZ

-ULA

032018 E

N

UNILIFT Sp. z o. o., sp. k. www.unilift.pl e-mail: [email protected] 2.

Contact data:

Address:

Company:

Contact person: Office:

Phone number: e-mail:

Date:

Support arm fastening by girder clips to the I-beam: yes Support arm length: L = mm

Examplesof mounting

Fastening on higher shelf:

min. 10

A

B/2

L

Hole Ć11 30

L

Fastening on lower:

min. 10

30

Hole Ć11

L

AB/2

Device localisation: indoor outdoor mixed

Environment: normal high humidity dust

chemically aggressive (description)

o oWorking temperature range: C min. C max.

Acceptable voltage drop:

Current collector speed:

at start (default: 5 %)

in continous (default: 2%)

m/min

Location of power points:

other (description)

at the end of the line