![Page 1: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/1.jpg)
Mobius Institute Category 1Chapter 2
![Page 2: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/2.jpg)
Mobius Institute Category 1Chapter 2
Infrared Thermography
Electric Motor Testing
Oil Analysis
Wear Particle Analysis
![Page 3: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/3.jpg)
Condition MonitoringInfrared Thermography
![Page 4: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/4.jpg)
Infrared Thermography
Infrared Thermography
Concept
Devices
• Spot Radiometer
• Infrared Camera
Application
• Mechanical Equipment
• Electrical Equipment
![Page 5: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/5.jpg)
Heat Transfer Modes
Conduction
Convection
Radiation
Radiation
Conduction
Convection
![Page 6: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/6.jpg)
Infrared Camera
Infrared Camera
1. Emitted
Heat
2. Reflected
Heat
3. Transmitted
Heat
![Page 7: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/7.jpg)
Conclusion
Conclusion
Reliable measurement
Advantage/disadvantag
e
![Page 8: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/8.jpg)
CONDITION MONITORINGELECTRIC MOTOR TESTING
![Page 9: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/9.jpg)
ELECTRIC MOTOR TESTING
MOTOR LISTRIK : energi listrik ---> energi mekanik
Tujuan dilaksanakannya electric motor testing umumnya adalah untuk
memastikan kondisi kesehatan dari mesin tersebut.
1. mendeteksi kondisi insulation.
2. mendeteksi electrical imbalances.
detect electrical condition
1. static/off-line test
2. dynamic/on-line test
![Page 10: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/10.jpg)
Static/off-line test
Static/off-line test :
Performed when motor off or shutdown
Usually performed once a year.
Quality assurance tool.
New base-line of future trending.
Troubleshooting
Off-line test include :
Traditional test method
Insulation resistance testing (meg-ohm)
Polarization index
High potential resistance testing
Surge comparison testing.
![Page 11: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/11.jpg)
Static/off-line
test
Traditional test
method
Insulation
resistance
testing
Polarization
index
High potential
resistance
testing
Surge
comparison
testing
• Memerlukan aplikasi tegangan
yang signifikan
• Menekan sistem insulation
• Tes insulation menggunakan
dc voltage
• Mengukur resistansi pada
insulation
• Variasi dari tes IR
• PI= R10/R1
• Polarization current
Tes resistansi menggunakan arus
DC tegangan rendah, tujuan
utamanya mendeteksi high
resistance joints, loose
connection, broken connection,
dan direct short
• Memonitor kondisi belitan dan
insulasi.
• Tes turn-to-turn, coil-to-coil,
phase-to-phase insulation.
![Page 12: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/12.jpg)
DYNAMIC/ON-LINE TEST
On-line test :
Performed when motor still on or operating
Can be performed daily, weekly, or monthly.
Condition monitoring.
Digunakan untuk mendeteksi
Winding shorts between conductor and coil
Winding contamination
Insulation to ground faults
Air gap faults, including eccentric motor
Rotor faults
Current analysis with current clamp.
Flux coil.
![Page 13: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/13.jpg)
DYNAMIC/ON-LINE TEST
Current spectra.
Collecting current data on each power leg at the panel using current clamp.
Comparing the current from each leg.
Current spectrum can detect probability of broken rotor bars, uneven air gap, bowed rotor.
Flux coil
Used on the motor.
Collect data of the flux field generated by motor.
Indicate potential problems at the windings.
![Page 14: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/14.jpg)
CONDITION MONITORINGOil analysis and Wear particle analysis
![Page 15: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/15.jpg)
Oil Analysis
Oil Analysis adalah tes yang dilakukan untuk mengetahui kondisi dari pelumas. Dan untukmengetahui apakah terdapat kontaminasi pada pelumas tersebut.
- Apakah masih bisa melakukan tugasnya dengan baik?
- Apakah ada kandungan air atau kotoran?
- Apakah ada logam atau unsur lain yang memberikan peringatan dini dari keausan.
Tes yang dapat ditambahkan :
- Visual Analysis
- Smell
![Page 16: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/16.jpg)
Oil Analysis
Advantages
Dapat menentukan kondisi bahan aditif
pada pelumas.
Dapat mendeteksi adanya kontaminasi
dari fluida lain.
Dapat membaca adanya keausan partikel
sampai 6 mikron.
Disadvantage
s
Tidak dapat membaca adanya “Abnormal
Wear Particle”
Tidak dapat menentukan sumber dari
keausan.
![Page 17: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/17.jpg)
Wear Particle analysis
Corrosive Wear
Sliding Wear
Cutting Wear
![Page 18: Condition monitoring part 2](https://reader031.fdocuments.us/reader031/viewer/2022020110/55aa6b9b1a28abd9528b4594/html5/thumbnails/18.jpg)
Oil Analysis vs Wear Particle Analysis