    Lecture 17

    1

    Condenser CoolingWater System

  • 8/12/2019 Condenser 1

    2/13

    Condenser Cooling Water (CCW)System Requirements

    Condenser maintains very low absolutepressure (near vacuum) through condensationprocess of steam (around 25200 times ofvolume reduction)

    This allows roughly 35% more energyextraction than if the steam is left atatmospheric pressure

    The effectiveness of the Condenser CoolingWater (CCW) causing condensation is

    therefore an important requirement 2

  • 8/12/2019 Condenser 1

    3/13

    Condenser Cooling Water (CCW)System Requirements

    While removing 70% of the reactors thermalpower into natural sources like river and sea,following are to be ensured:

    Minimize the extent of thermal pollution in thereceiving water by limiting a temperature rise of5C within the shortest distance from the outfall

    Minimize hot water recirculation at the intake CCW flow is to be adjusted to keep the

    condensate at saturation temperature as

    subcooling would reduce thermal cycle 3

  • 8/12/2019 Condenser 1

    4/13

    Functions and Ratings of CCWSystem

    The breakup of cooling water flowrequirement and heat load for a typical 220MWe NPP is:

    4

    Equipment Flow required (m 3/hr) Heat load (K.cal/hr)

    Main condenser 33230 4.452 x 10 8

    Turbine oil cooler 550 1.06 x 10 6

    Boiler blow down cooler 90 0.9 x 10 6

    Air extraction unit 108 0.4 x 10 6

    Total CCW flow 33993

    *Other NPP systems 2401 8.775 x10 6

  • 8/12/2019 Condenser 1

    5/13

    Functions and Ratings of CCWSystem

    Number of CCW pumps 3 Pump head 25.50 mWC Shut-off head 42 mWC

    Type Mixed flow vertical turbinebowl assembly pull outtype

    Capacity 11650 m 3/hr Motor rating 1100 KW

    CCW tunnels 3000mm (W) x2500mm (D) based on 1.3m/sec design velocity 5

  • 8/12/2019 Condenser 1

    6/13

    Functions and Ratings of CCWSystem

    6

    Simplified Condenser Cooling Water (CCW) Systems

  • 8/12/2019 Condenser 1

    7/13

    CCW Pumps

    These are high flow pumps with low dischargehead

    They have a mixed flow characteristic Generally, started with discharge valve, part

    open to limit startup current

    Butterfly valve in pump discharge is kept fullopen, when the pump is operating Pump bearings are rubber lined and cooled by

    clean water

    7

  • 8/12/2019 Condenser 1

    8/13

    A View of Water Intake System

    8

    Stop Gate

    Trash Rake

    Dual Flow Travelling

    Water Screen

  • 8/12/2019 Condenser 1

    9/13

    Travelling Water Screen

    Travelling water screens are provided at pumpsuction to filter CCW water continuously

    This removes particles of over half inch The screen has rotating buckets which are

    cleaned by water jet

    Screen Dp is monitored continuously and italarms when it exceeds the preset value

    9

  • 8/12/2019 Condenser 1

    10/13

    Travelling Water Screen

    10

  • 8/12/2019 Condenser 1

    11/13

    Travelling Water Screen

    11

  • 8/12/2019 Condenser 1

    12/13

    Operational Limitations andProblems in CCW System

    The requirement about minimizing thermalpollution in the receiving water by limiting atemperature rise of 5C within the shortestdistance from the outfall is a limitation

    This is because warmer station affluent canaffect local aquatic life, promoting growth ofsome species and endagering others

    So limits are imposed on cooling waterteperature rise (T) and affluent temperature

    (TE) 12

  • 8/12/2019 Condenser 1

    13/13

    Water Hammer Prevention

    The very large CCW flow rate causesenoromous kinetic energy of the flowingwater

    This promotes severe water hammer duringCCW pump startup, shutdown and trips

    Following general operating practices to beused for water hammer prevention:

    Sufficient time delay before the next pump isstarted

    Proper positioning and slow opening/closing of 13