CSL’s Invizilite Generation 2 is the most flexible and versatile concealed

lighting system to date. Invizilite Generation 2 has been developed to

answer all of the most challenging concealed lighting issues. Tight radii,

sharp turns, confined coves and restrictive spaces are not a problem for

Invizilite Generation 2. CSL’s patent pending system features a flexible

two-conductor cable that allows maximum freedom for quick and easy

installation and provides high load capacity for more light and fewer

power feeds.

Invizilite Generation 2 is designed to be installed without the use of a

rigid track, making free-form designs a breeze. The Invizilite Generation

2 socket will accommodate incandescent and xenon festoon lamps, our

High-Power one watt LED modules or an MR lampholder. In addition, the

sockets may be removed and/or relocated to place the light right where

it’s needed.

A complete selection of accessories is available for Invizilite

Generation 2, including mounting tracks, reflectors,

lenses and connectors.

•Availableineitherkits(withcableandpre-attachedsockets)orasseparatecomponents(cableandsockets)•Previouslyinstalledsocketsmayberepositioned

or removed•Socketsareinstalledusingordinaryhandtools•Doublesidedtapeisadheredtothebaseforpositioning•Mountingearsmaybepositionedoneithersideofthe

socket, for a secure installation

•Two-conductor cable capable of carrying high loads, 24V - 25A•Remarkableflexiblity•Cablemarkedatone-inchandone-footincrements•Proprietarypatentpending

•Polycarbonatetracksareavailablewhenstraight-linerunsare desired •Socketssnapintotheextrusionsforfast,secure

installations

CONTENTS

ORDERING GUIDE 3

KITS 4

SOCKETS & CABLE 6

TRACK & LENSES 7

ACCESSORIES 9

REFLECTORS 10

TRANSFORMERS 11

INSTALLATION GUIDE 12

LAMPS 13

PHOTOMETRICS 14

INDEX 15

•Patentpendingtwo-conductorcable•Capableofmakingtightcornersandbendswithoutthe

need for splicing or additional corner connectors.

Page 3: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

- Magnetic: Maximum wattage 600W @ 24V on a single load,

multi-tap options. If selecting I.E. Laminated type, keep

within 30' of first socket of run, if selecting Toroidal type,

keep within 60' of first socket of run. Works well with

advanced dimming systems. Bulky and heavy but has high

wattagemax(@24V),canberunatmaxwattageloadand

can be installed a long distance from the first socket. Best

for far distance installation from run and for long lighting

runs of up to 23' @ 12V, 40' @ 24V with Xenon lamps.

5. Select best Invizilite Generation 2 option for the application:

•Pre-assembledkits

•Masterkits

•Customcut

•Individualcomponents

(accessoriesavailablebutnotnecessarytooperatesystem)

33

CONCEALED LINEAR SYSTEM IN 5 EASY STEPS

1. Measure length of desired run

2. Depending on application, determine socket spacing between

socket centers, i.e.: inch on center “O.C.” spacing

• forcove lighting:use thegeneral rule that thedistance in

inches from the wall is equal to the socket spacing: 4" cove/

soffit = 4" O.C. socket spacing.

• for task lighting:whenmore light is desired on thework

surface,useclosersocketspacing(O.C.socketspacing).

3. Select desired lamp and wattage for the application:

•Xenonfestoon

•LED

•MR11/MR8

4. Select transformer

•12Vor24V?

- Keep in mind:

12V=300Wmax(shortruns)

24V=600Wmax(longruns)

- To determine total wattage: number of lamps x

watts/lamp = total wattage of linear run

- Divide total watts by 300W if 12V or 600W

if24V=numberoftransformersrequired(roundup)

•ElectronicorMagnetic

- both primary and secondary circuited and fused

- Electronic: Maximum wattage 300W on a single load and

mustbewithin8'-10'offirstsocketofrun.Small,light

weight, can be run at max wattage load, easy to hide on

remote installation and inside coves and cabinets. Best for

short runs of up to 16' @12V, 22' @24V with Xenon lamps

Page 4: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

• Pre-assembledMasterKitscompletewith:

• Socketspre-attachedat4inchO.C.spacing

• Doublesidedtapeandmountingearspre-installed for installation

• Screws,startingterminalblock,endcap

• Lampsandappropriatetransformer for maximum run

• 10footor20footkitoptionsinwhiteorblackcable:fieldcuttable

• Choiceof5wattor10wattxenonlamps

• Electronictransformer(12V300W)suppliedforall 10 foot kits and 20 foot 5 watt kits

• Magnetictransformer(24V600W)supplied with 20 foot, 10 watt kit

• Factorycutrunatperfootlengthswithsocketsattachedateither 2 1/4", 3", 4" and 6" O.C. socket spacing

• Includesdoublesidedtapeandmountingearpre-attachedtosocket

• 2"whipaddedtobeginningofeachrunfor easy wiring

• Mustinstallwith:INVPW1(orcoveredwirenuts),INVDE1andINVSC(screwsformechanicalfastening)

4

MASTER KITS

INVIZILITE GENERATION 2 CUSTOM CUT PROGRAM

44

Cat. No. Cable Color Lamp Wattage

Voltage Length Spacing Sockets Lamps Included

TransformerWatts/Type

INV10-4WT-5-12 WT 5 12 10' 4" 30 30 300WElectronicINV10-4BK-5-12 BK

INV10-4WT-10-12 WT 10 12 10' 4" 30 30 300WElectronicINV10-4BK-10-12 BK

INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300WElectronicINV20-4BK-5-12 BK

INV20-4WT-10-24 WT 10 24 20' 4" 60 60 600WMagneticINV20-4BK-10-24 BK

Cat. No. Cable Color Description

INVWT-2 WT 1" Invizilite G2 w/sockets mounted @ 2.25" O.C. spacing. Double sided tape and mounting ears pre-attached (INVPW-1, INVDE1, accessories, lamps & transformers sold separately) NOTE: 5W MAX.INVBK-2 BK

INVWT-3 WT 1" Invizilite G2 w/sockets mounted @ 3" O.C. spacing. Double sided tape and mounting ears pre-attached (INVPW-1, INVDE1, accessories, lamps & transformers sold separately)INVBK-3 BK

INVWT-4 WT 1" Invizilite G2 w/sockets mounted @ 4" O.C. spacing. Double sided tape and mounting ears pre-attached (INVPW-1, INVDE1, accessories, lamps & transformers sold separately)INVBK-4 BK

INVWT-6 WT 1" Invizilite G2 w/sockets mounted @ 6" O.C. spacing. Double sided tape and mounting ears pre-attached (INVPW-1, INVDE1, accessories, lamps & transformers sold separately)INVBK-6 BK

INV-CUT N/A Individual cut charge for Invizilite Generation 2 Custom Cut program

Page 5: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

Invizilite Generation 2 is available in pre-assembled

kits. Kits may be ordered with black or white cable,

socket spacing of 3 inches, 4 inches or 6 inches and

in spools of 20 feet, 60 feet, 100 feet and 200 feet.

Kits are furnished with sockets pre-attached to the

cable(mountingearsareattachedtothesockets in

an alternating pattern). Mounting screws, power feeds

and dead ends are also included in the kits. Lamps,

transformers and accessories are ordered separately.

Cat. No. Color Length Spacing SocketsINV20-3WT WT 20' 3" 80INV20-3BK BKINV20-4WT WT 20' 4" 60INV20-4BK BKINV20-6WT WT 20' 6" 40INV20-6BK BKINV60-3WT WT 60' 3" 240INV60-3BK BKINV60-4WT WT 60' 4" 180INV60-4BK BKINV60-6WT WT 60' 6" 120INV60-6BK BKINV100-3WT WT 100' 3" 400INV100-3BK BKINV100-4WT WT 100' 4" 300INV100-4BK BKINV100-6WT WT 100' 6" 200INV100-6BK BKINV200-3WT WT 200' 3" 800INV200-3BK BKINV200-4WT WT 200' 4" 600INV200-4BK BKINV200-6WT WT 200' 6" 400INV200-6BK BK

•1- power feed (INVPW1) and 1- dead end (INVDE) provided per 20'. 1 set per 20' kit, 3 sets per 60' kit, 5 sets per 100' kit and 10 sets per 200' kit. Mounting screws included.

KITS

5

Page 6: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

1.9580

0.8450

FESTOON SOCKET AND BASE

Cat. No. QuantityINVF-10 10INVF-100 100

MR8 / MR11 FESTOON ADAPTER

Cat. No. Watts Voltage Lamp BaseINVMR 20 Max 12~24 G4

MR11 REFLECTOR SHIELD

Cat. No. FinishINV11CA Satin AluminumINV11CB BlackINV11CW White

SOCKET MOUNTING EARS AND SCREWS

Cat. No. QuantityINVME-10 10INVME-100 100INVSC-100 100 Mounting Screws

INVIZILITE CABLE - W/O SOCKETS

Cat. No. Length ColorINV20WT 20' WTINV20BK 20' BKINV60WT 60' WTINV60BK 60' BKINV100WT 100' WTINV100BK 100' BKINV200WT 200' WTINV200BK 200' BKINV500WT 500' WTINV500BK 500' BK

SOCKETS & CABLE

•SocketandbasesnaptogetherontotheInvizilitecablewithouttheuseofatrack•Multi-usesocket:acceptsfestoonlamps,INVMRadapterforMR8andMR11

lamps and CSL’s LED festoon module•Pre-attacheddouble-sidedtapeandmountingear•Thecombinationofthehightemppolycarbonatehousingandaluminumheat

shield allows the socket to be rated at 10W maximum festoon, 20W MR•Highgradeclearpolycarbonateconstruction,withstainlesssteellampclips•SnapsintoINV4STE,INV4WWE,INV4CE•INVME Mounting Ear is included with socket. Additional pieces ordered

below

•ConcealstheglareandlightleakfromthereflectorshellofanMR-11lamp•EasilysnapsaroundMRadapter•3finishoptions:White,BlackandSatinAluminum

•Superflexibletwo-conductorcable,24V25Amaximum–300W/12V,600W/24V•Self-healingcableinsulationismarkedin1"and1'increments•Spoolsin20',60',100',200'and500'•WhiteandBlack

•ConvertsfestoonsocketintoanMR8orMR11adjustablespotlight•Acceptsupto20WMR8&MR11•ConstructedfromhightemperaturePolyphenyleneSulfide(PPS)

6

Page 7: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

7

LENSES

• 4' prismatic lens snaps over top of the standard and chaser tracks tosmooth light distribution and for protection of sockets, lamps and cable•Extrudedfromclearhighgradepolycarbonate,fieldcuttable•12v5wattmaximum@3"orgreaterspacing 12v 3 watt maximum @ 2¼" spacing 24v 3 watt maximum @ 3" or greater spacing

PRISMATIC LENS FOR STANDARD & CHASE EXTRUSION

Cat. No. Quantity Length ColorINV4PLS 4 48" Clear Prismatic

SINGLE SOCKET PRISMATIC LENS

Cat. No. Quantity Length ColorINVSKTCVR-10 10 2" Clear Prismatic

•2"singlesocketprismaticlens•Easyinstallation,snapsovertheInvizilitefestoonsocket•Extrudedfromclearhighgradepolycarbonate•12v10wattmaximum@3"orgreaterspacing 24v 5 watt maximum @ 3" or greater spacing

7

Page 8: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

•4'Angledtracktosupportsocketsandcableinastraightrunata45degreeangle•Socketssnapeasilyintotrack–notoolsrequired•Extrudedfromclearhighgradepolycarbonateforstrengthanddurability•Easyinstallation:3pre-drilledholesper4'extrusion,fieldcuttableanddrillable8

•4'Standardtracktosupportsocketsandcableinastraightrun• Sockets snap easily into track after sockets have been installed onto cable–notoolsrequired•Extrudedfromclearhighgradepolycarbonateforstrengthanddurability•Flexible–minimum4'radius•Easyinstallation:3predrilledholesper4'extrusion,fieldcuttableanddrillable•UsewithINV4PLStocoversystemwithaprismaticlens(notflexible)

•4'Standardtrackwithadditionalwirewayalongsidesforlongerrunswithoutgoing back to the transformer•Clearhighgradepolycarbonateextrusionallowstwo10-gaugewires,oneper

side, to chase along the run for an additional power feed• Sockets snap easily into track after sockets have been installed onto cable–notoolsrequired•Easyinstallation:3predrilledholesper4'extrusion,fieldcuttableanddrillable•Trackisflexibletoa4'radius

•4'prismaticlenssnapsovertopofthewallwashtrackforprotectionofsockets,lamps and cable as well as helping even light distribution•Extrudedfromclearhighgradepolycarbonate,fieldcuttable•12v5wattmaximum@3"orgreaterspacing 12v 3 watt maximum @ 2¼" spacing 24v 3 watt maximum @ 3" or greater spacing

PRISMATIC LENS FOR WALL WASH EXTRUSION

Cat. No. Quantity Length ColorINV4PLW 4 48" Clear Prismatic

TRACK EXTRUSION

Cat. No. Quantity Length ColorINV4STE 4 48" Clear

TRACK EXTRUSION W/ CHASE WIREWAY

Cat. No. Quantity Length ColorINV4CE 4 48" Clear

ANGLED TRACK EXTRUSION

Cat. No. Quantity Length ColorINV4ANGE 4 48" Clear

TRACKS

•4'Standardtrackwithintegralwallwashextrusion•Fasciaconcealsthesysteminapplicationssuchasundercabinetsorshelves• Sockets snap easily into track after sockets have been installed onto cable–notoolsrequired•Extrudedfromhigh-gradepolycarbonateforstrengthanddurability•Easyinstallation:3predrilledholesper4'extrusion,fieldcuttableanddrillable•UsewithINV4PLWtocoversystemwithaprismaticlens

WALL WASH EXTRUSION

Cat. No. Quantity Length ColorINV4WWE 4 48" White

8

Page 9: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

•UL&CULlisted30ampterminalblock,10AWGmax.•Housingandhingedlidareconstructedfromclearhighgradepolycarbonate•SnapsintoINV4STE,INV4WWE,INV4CE

•Useforthestartofarunbyjoiningtheconnectionfromthetransformertothe Invizilte Generation 2 low voltage cable within box•Constructedfrom16gaugegalvanizedsteel•MeetsUL2108ULcodes

•Multi-usewiringcompartmenttouseforeitherthestartofarunortocreatean “L” or “T” connection within the run•Constructedfrom16gaugegalvanizedsteel•MeetsUL2108ULcodes

•Deadendtermination,snapsoverendofcablewithnotool•Doublesidedtapeandmountingearwithscrewincludedforinstallation•SnapsintoINV4STE,INV4WWE,INV4CE•Highgradeclearpolycarbonateconstruction

•Securescabletosurfacebetweenlongdistancesofsockets•Installswithpre-attacheddoublesidedtapeorpre-drilledholeforscrewdown•Highgradeclearpolycarbonateconstruction

•Useforthestartofarunbyjoiningtheconnectionfromthetransformertothe Invizilite Generation 2 low voltage cable within box•Constructedfrom16gaugegalvanizedsteel•Lowprofile,1"Tall•MeetsUL2108standard

9

TERMINAL BLOCK W/ COVER

Cat. No. Dimensions Quantity

INVPW1 14"L x d"W x m"H 1

INVPW1-10 14"L x d"W x m"H 10

END-FEED WIRING COMPARTMENT

Cat. No. DimensionsINVWC1 4"L x 28"W x 1¾"H

DEAD END CAP

Cat. No. Color QuantityINVDE1 Clear 1INVDE1-10 Clear 10

METAL THREE-WAY WIRING COMPARTMENT

Cat. No. DimensionsINVWC2 5d"L x 22"W x 1¾"H

LOW PROFILE WIRING COMPARTMENT

Cat. No. DimensionsINVWC3 4"L x 28"W x 1"H

CABLE CLIP

Cat. No. Quantity ColorINVCL-10 10 ClearINVCL-100 100 Clear

ACCESSORIES

9

Page 10: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

•Attachestosockettomultiplylightoutput•Breakawayabilitytocreateasymmetricreflectorsforvariablelightingeffects•Constructedfromhighgradesemi-specularaluminum

•60°paintedsteelkickreflector•SlidesintoINVFtocreateanasymmetriclightspread•3finishoptions:Black,BronzeandWhite

•90°paintedsteelkickreflector•SlidesintoINVFtocreateasymmetriclightspread•3finishoptions:Black,BronzeandWhite

PARABOLIC SOCKET REFLECTOR

Cat. No. QuantityINVPR-10 10

ANGLED KICK REFLECTOR

Black Bronze White QuantityINVAKRB-10 INVAKRBZ-10 INVAKRW-10 10

90° KICK REFLECTOR

Black Bronze White QuantityINVSKRB-10 INVSKRBZ-10 INVSKRW-10 10

REFLECTORS

10

Page 11: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

MAGNETIC TRANSFORMERS

Cat. No. Wattage Voltage Description Dimensions Weight

T-118 150W 12V 150 watt 12 volt E.I. laminated magnetic transformer, multi-tap with primary and secondary internal circuit protection

8¾" x 4¼" x 3¾" 15 lbs

T-119 150W 24V 150 watt 24 volt E.I. laminated magnetic transformer, multi-tap with primary and secondary internal circuit protection

8¾" x 4¼" x 3¾" 15 lbs

T-120 300W 12V 300 watt 12 volt E.I. laminated magnetic transformer, multi-tap with primary and secondary internal circuit protection

8¾" x 4¼" x 3¾" 15 lbs

T-121 300W 24V 300 watt 24 volt E.I. laminated magnetic transformer, multi-tap with primary and secondary internal circuit protection

8¾" x 4¼" x 3¾" 15 lbs

T-122 600W(2-300)

12V 600 watt 12 volt E.I. laminated magnetic transformer, multi-tap with primary and secondary internal circuit protection

9½" x 6¼" x 4¾" 22 lbs

T-123 600W 24V 600 watt 24 volt E.I. laminated magnetic transformer, multi-tap with primary and secondary internal circuit protection

9½" x 6¼" x 4¾" 22 lbs

T-124 300w 12V 300 watt 12 volt toroidal magnetic transformer, multi-tap with primary and secondary internal circuit protection

9½" x 5¼" x 4¾" 15 lbs

T-125 300W 24V 300 watt 24 volt toroidal magnetic transformer, multi-tap with primary and secondary internal circuit protection

9½" x 5¼" x 4¾" 15 lbs

T-126 600W(2-300)

12V 600 watt 12 volt toroidal magnetic transformer, multi-tap with primary and secondary internal circuit protection

10½" x 6¼" x 5¾" 22 lbs

T-127 600W 24V 600 watt 24 volt toroidal magnetic transformer, multi-tap with primary and secondary internal circuit protection

10½" x 6¼" x 5¾" 22 lbs

T-128 900W(3-300)

12V 900 watt 12 volt E.I. laminated magnetic transformer, multi-tap with primary and secondary internal circuit protection

10½" x 6¼" x 5¾" 22 lbs

LED DRIVERS

Cat. No. Wattage Voltage Description Dimensions Weight

D-105 25W 12Vdc 12V constant voltage LED driver for use with L-232 and L-233 6x" x 1x" x 1¾" .3 lbs

D-106 60W 12Vdc 12V constant voltage LED driver for use with L-232 and L-233 7m" x 1w" x 1b" 1.25 lbs

D-107 100W 12Vdc 12V constant voltage LED driver for use with L-232 and L-233 9z" x 2b" x 1n" 1.75 lbs

ELECTRONIC TRANSFORMERS

Cat. No. Wattage Voltage Description Minimum Load Dimensions Weight

ELVT-IV2 60W 12 Class 2, 60watt 12volt electronic transformer 10watt w/o dimmer 20watt w/ dimmer

m" x 1c" x 28" 3 oz

T-17ENCL 60W 12 Enclosed, 60watt 12volt electronic transformer 50watt 1v" x 12" x 62" 1 lbs

T-30BK(Black)

60W 12 Class 2, 60watt 12volt plug in electronic transformer 20watt 1c" x 12" x 3x" 3 oz

T-30(White)

60W 12 Class 2, 60watt 12volt plug in electronic transformer 20watt 1c" x 12" x 3x" 3 oz

T-13ENCL 150W 12 Enclosed, 150watt 12volt electronic transformer 50watt 1v" x 12" x 62" 1 lbs

T-14ENCL 150W 24 Enclosed, 150watt 24volt electronic transformer 50watt 1v" x 12" x 62" 1 lbs

T-15ENCL 300W 12 Enclosed, 300watt 12volt electronic transformer 50watt 1v" x 1n" x 92" 1.5 lbs

T-16ENCL 300W 24 Enclosed, 300watt 24volt electronic transformer 50watt 1v" x 1n" x 92" 1.5 lbs

TRANSFORMERS

11

Page 12: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

Voltage Drop Chart

Usethischarttoestablishthecorrectwiregaugetominimizevoltagedropatthespecifiedwattage.Thedistanceshownisthelengthofwire

from the transformer to the first fixture in the run.

Maximum Watts per Feed < 5 feet 6 – 15 feet 16 – 20 feet 21 – 40 feet 41 – 60 feet 61 – 90 feet

12 Volt, 300 Watt Max. 12 ga 8 ga 6 ga 4 ga 2 ga 1 ga

24 Volt, 600 Watt Max. 14 ga 12 ga 10 ga 6 ga 6 ga 4 ga

The information in this section will help you determine the design and

layout of the Invizilite Generation 2 Low-Voltage Lighting System.

Operating Temperatures

As with every lighting system, the Invizilite Generation 2 will generate

heat during operation. Sufficient ventilation is required to dissipate the

heat generated during operation. The Invizilite Generation 2 system

is not intended to be installed in area where air flow is restricted. The

surface the Invizilite Generation 2 is mounted to must not exceed

90°C(194°F).

Low Voltage Transformers

A low voltage transformer is required to power the Invizilite

Generation 2 system. There are two types of low voltage transformers:

electronic and magnetic. To guarantee safety and maintain warranty

alwaysuseaULlistedorULrecognizedtransformer.

Electronic Transformers

Electronic transformers have smaller profiles than magnetic

transformers.Theyareavailableinsizeswithsingleoutputsof60–300

watts. Each transformer has waterproof potting in a cast aluminum

housing. The electronic transformers have short circuit and auto-reset

thermal cut-off protection at 125°C. Electronic transformers may

causeRFI(RadioFrequencyInterference).IfRFIispresent,reposition

thetransformerbyrotating it(plugit intheoppositeway)changing

thedirectionofthemagneticfield.RFIcanbeeliminatedbyusinga

magnetictransformerwhichdoesnotcauseRFI.

Magnetic Transformers

Magnetic transformers are typically larger and weigh more than an

electronic transformer. They are available in 300watt or 600watt,

Toroidal or E.I. lamination. The 12volt transformers have four multi-

taps 12, 13, 14, 15 or 24, 26, 28, 30 for the 24voltmodels. These

magnetic transformers have an auto reset in-line primary overload

protection and an in-line secondary magnetic breaker to protect

against short circuit. All of our magnetic transformers may be loaded

up to 100% when mounted horizontally.

Dimming Transformers

Invizilite Generation 2 may be dimmed. When dimming this system,

it is recommended that the dimmer be installed on the line voltage

(primary)sideofthetransformer.Whenusingamagnetictransformer

it is recommended to use a low voltage dimmer suitable for use with

a magnetic transformer. When using an electronic transformer it is

recommended that you use a low voltage electronic dimmer.

Switching

Forinstallationsthatrequireswitchingonthelowvoltage(secondary)

side, it is important that the switch being used is rated for the amperage

that the Invizilite Generation 2 system is drawing through it. You can

calculateamperageusingthefollowingequation:Amps(amperage)=

Total Watts ÷ Voltage. If there is confusion about which switch to use,

use a switch with a minimum rating of 25amps and this will cover the

maximum rating of the Invizilite Generation 2 system.

Transformer Placement

Transformers should be placed as close as possible to the start of the

Invizilite Generation 2 run to help compensate the voltage drop that

may occur. Electronic transformers are more susceptible to voltage

drop and it is recommended that electronic transformers are not used

for long runs or used in a remote mounting application.

Remote Mounting Transformers

When remote mounting a magnetic transformer, it is important to

select the correct wire gauge for use between the transformer and

thebeginningoftheInviziliteGeneration2runs.Usethechartbelow

to establish the correct wire gauge.

Voltage Drop

When the first lamp in the run is brighter than the last lamp in the

run, this difference is known as voltage drop. Voltage drop can be

minimized by selecting the correct wire gauge between the remote

transformer and the start of the run. Refer to the chart below.

Reducing Voltage Drop

1.Useamulti-taptransformer.

2. Usethecorrectgaugewirefromtransformertothestartoftherun.

3. Place the power feed in the center of the run.

INSTALLATION GUIDE

12

Page 13: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

LAMPS

1 WATT LED FESTOON MODULE

Cat. No. Quantity Watts Voltage Lumens Avg Temp

L-221

Cool White

2 1 12 90 5000°K

L-224-HO

Warm White

2 1 12 50 3000°K

L-222

Warm White

2 1 24 50 3000°K

.5 WATT LED FESTOON MODULE

Cat. No. Quantity Watts Voltage Lumens Avg Temp

L-232

Warm White

2 .5 12 25 2800°K

L-233

Cool White

2 .5 12 25 5000°K

•HighPower1WattLED•Longlife:approximately50,000hours•Energyefficient-1.4Wattinput/1Wattoutput•SnapsintoINVFwithoutuseofatool•ColorTemperaturevaries≥ 500ºK max.•TheL-221andL-224-HOworkswith12V

electronic or magnetic transformers. The L-222 works with 24V electronic or magnetic transformers•12Vdimmabledownto10%(matchdimmer

with transformer type) 24V not dimmable•24V(L-222)versionforlongrunsonsingle

power source

•.5WattpowerLED•Longlife:50,000hours@70%lmmaintenance•SnapsintoINVFwithoutuseofatool•TheL-232&L-233workswith12V DC

driver only(D-105,D-106,D-107)•Notdimmable

XENON FESTOON

Cat. No. Quantity Watts Voltage Lumens TypeLXC312-25 25 3 12 25 ClearLXC312-100 100LXF312-25 25 3 12 25 FrostedLXF312-100 100LXC512-25 25 5 12 50 ClearLXC512-100 100LXF512-25 25 5 12 50 FrostedLXF512-100 100LXC1012-25 25 10 12 120 ClearLXC1012-100 100LXF1012-25 25 10 12 120 FrostedLXF1012-100 100LXC324-25 25 3 24 25 ClearLXC324-100 100LXF324-25 25 3 24 25 FrostedLXF324-100 100LXC524-25 25 5 24 50 ClearLXC524-100 100LXF524-25 25 5 24 50 FrostedLXF524-100 100LXC1024-25 25 10 24 120 ClearLXC1024-100 100LXF1024-25 25 10 24 120 FrostedLXF1024-100 100

MR8

Cat. No. Quantity Watts Voltage Type BeamLM82012S-10 10 20 12 Spot 10°LM82012F-10 10 20 12 Flood 30°LM82024S-10 10 20 24 Spot 10°LM82024F-10 10 20 24 Flood 30°

MR11

Cat. No. Quantity Watts Voltage Type BeamLM112012S-10 10 20 12 Spot 10°LM112012F-10 10 20 12 Flood 30°LM112024S-10 10 20 24 Spot 10°LM112024F-10 10 20 24 Flood 30°

13

Page 14: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

0°A

45°B

90°C

14

12 Volt 3 Watt Xenon Festoon

Lamp Spacing

Measuring Point 6” 12” 18” 24”

3” A ( 0° ) 100 fc 25 fc 11 fc 6 fc

B (45°) 124 fc 31 fc 14 fc 8 fc

C (90°) 80 fc 20 fc 9 fc 5 fc

4” A ( 0° ) 80 fc 20 fc 9 fc 5 fc

B (45°) 96 fc 24 fc 11 fc 6 fc

C (90°) 64 fc 16 fc 7 fc 4 fc

6” A ( 0° ) 40 fc 10 fc 4 fc 3 fc

B (45°) 48 fc 12 fc 5 fc 3 fc

C (90°) 32 fc 8 fc 4 fc 2 fc

12 Volt 5 Watt Xenon Festoon

Lamp Spacing

Measuring Point 6” 12” 18” 24”

3” A ( 0° ) 160 fc 40 fc 18 fc 10 fc

B (45°) 196 fc 49 fc 22 fc 12 fc

C (90°) 124 fc 31 fc 14 fc 8 fc

4” A ( 0° ) 128 fc 32 fc 14 fc 8 fc

B (45°) 152 fc 38 fc 17 fc 10 fc

C (90°) 100 fc 25 fc 11 fc 6 fc

6” A ( 0° ) 92 fc 23 fc 10 fc 6 fc

B (45°) 108 fc 27 fc 12 fc 7 fc

C (90°) 72 fc 18 fc 8 fc 5 fc

12 Volt 10 Watt Xenon Festoon

Lamp Spacing

Measuring Point 6” 12” 18” 24”

3” A ( 0° ) 324 fc 81 fc 36 fc 20 fc

B (45°) 396 fc 99 fc 44 fc 25 fc

C (90°) 256 fc 64 fc 28 fc 16 fc

4” A ( 0° ) 256 fc 64 fc 28 fc 16 fc

B (45°) 308 fc 77 fc 34 fc 19 fc

C (90°) 204 fc 51 fc 23 fc 13 fc

6” A ( 0° ) 208 fc 52 fc 23 fc 13 fc

B (45°) 248 fc 62 fc 28 fc 16 fc

C (90°) 164 fc 41 fc 18 fc 10 fc

LED Modules

PHOTOMETRICS

Contact factory for current photometric data.

Page 15: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

151515

INDEX

D-105 11

D-106 11

D-107 11

ELVT-IV2 11

INV10-4WT-5-12 4

INV10-4BK-5-12 4

INV10-4WT-10-12 4

INV10-4BK-10-12 4

INV20-4WT-5-12 4

INV20-4BK-5-12 4

INV20-4WT-10-24 4

INV20-4BK-10-24 4

INV100-3BK 5

INV100-3WT 5

INV100-4BK 5

INV100-4WT 5

INV100-6BK 5

INV100-6WT 5

INV100BK 5

INV100WT 5

INV11CA 6

INV11CB 6

INV11CW 6

INV200-3BK 5

INV200-3WT 5

INV200-4BK 5

INV200-4WT 5

INV200-6BK 5

INV200-6WT 5

INV200BK 6

INV200WT 6

INV20-3BK 5

INV20-3WT 5

INV20-4BK 5

INV20-4WT 5

INV20-6BK 5

INV20-6WT 5

INV20BK 6

INV20WT 6

INV4ANGE 8

INV4CE 8

INV4PLS 8

INV4PLW 8

INV4STE 8

INV4WWE 8

INV500BK 6

INV500WT 6

INV60-3BK 5

INV60-3WT 5

INV60-4BK 5

INV60-4WT 5

INV60-6BK 5

INV60-6WT 5

INV60BK 5

INV60WT 5

INVAKRB-10 10

INVAKRBZ-10 10

INVAKRW-10 10

INVBK-2 4

INVBK-3 4

INVBK-4 4

INVBK-6 4

INVCL-10 9

INVCL-100 9

INVDE1 9

INVDE1-10 9

INVF-10 6

INVF-100 6

INVME-10 6

INVME-100 6

INVMR 6

INVPR-10 10

INVPW1 9

INVPW1-10 9

INVSC-100 6

INVSKRB-10 10

INVSKRBZ-10 10

INVSKRW-10 10

INVSKTCVR-10 7

INVWC1 9

INVWC2 9

INVWC3 10

INVWT-2 4

INVWT-3 4

INVWT-4 4

INVWT-6 4

L-221 13

L-222 13

L-224 13

L-232 13

L-233 13

LM112012F-10 13

LM112012S-10 13

LM112024F-10 13

LM112024S-10 13

LM82012F-10 13

LM82012S-10 13

LM82024F-10 13

LM82024S-10 13

LXC1012-100 13

LXC1012-25 13

LXC1024-100 13

LXC1024-25 13

LXC312-100 13

LXC312-25 13

LXC324-100 13

LXC324-25 13

LXC512-100 13

LXC512-25 13

LXC524-100 13

LXC524-25 13

LXF1012-100 13

LXF1012-25 13

LXF1024-100 13

LXF1024-25 13

LXF312-100 13

LXF312-25 13

LXF324-100 13

LXF324-25 13

LXF512-100 13

LXF512-25 13

LXF524-100 13

LXF524-25 13

T-13ENCL 11

T-14ENCL 11

T-15ENCL 11

T-16ENCL 11

T-18 11

T-19 11

T-30 11

T-30BK 11

T-118 11

T-119 11

T-120 11

T-121 11

T-122 11

T-123 11

T-124 11

T-125 11

T-126 11

T-127 11

T-128 11

Page 16: CONCEALED LINEAR LIGHTING - Platt Electric Supply Catalog - 2009.pdfINV10-4WT-10-12 WT 10 12 10' 4" 30 30 300W INV10-4BK-10-12 BK Electronic INV20-4WT-5-12 WT 5 12 20' 4" 60 60 300W

CREATIVE LIGHTING SOLUTIONSFOR A CHANGING ENVIRONMENT

14625 E. Clark Avenue

City of Industry, CA 91745

T: 626.336.4511

F:626.330.4266

www.csllighting.com