COMPUTRAC Vapor Pro - azic.com · Green Moisture Specific Instrumenta on uses Rela ve-Humidity, a...

2
ARIZONA INSTRUMENT LLC 3375 N Delaware St | Chandler, AZ www.azic.com APPLICATIONS Agricultural Products AutomoƟve BaƩeries Biological Products Bulk | Intermediate Chemicals Electronics Explosives Fine | Specialty Chemicals InjecƟon Molders Oils | Greases Petrochemicals Petroleum Renery PlasƟc Recycling Polymers Powder Bulk Solids Resin Manufacturing Rubber | PlasƟcs CERTIFICATIONS ASTM D7191-05 Standard Test Method for DeterminaƟon of Moisture in PlasƟcs by RelaƟve Humidity Sensor UL LisƟng (U.S. and Canada) CE CerƟcaƟon Green Moisture Specic InstrumentaƟon uses RelaƟve-Humidity, a sensor based technology that correlates to Karl Fischer coulometric ƟtraƟon, to determine moisture percentage. The analyzers match in precision and accuracy, but do not uƟlize reagents, minimizing consumables (green), and is simple to operate. The casing is suitable for a lab environment, but with the ruggedness and durability suitable for a producƟon environment. Our customers also enjoy free loaners, free method development and access to our full service lab over the lifeƟme of their instrumentaƟon. FEATURES ConƟnuous display of test Ɵme, current temperature, programmed test temperature, current microgram water measurement, and calculated moisture content StaƟsƟcal features calculate mean, standard deviaƟon and relaƟve standard deviaƟon Temperatures are programmable; maintained within ±1°C | Temperature CalibraƟon Interface Real-Ɵme graph of moisture curve and rate of moisture loss Easy setup of product methods to ensure opƟmum test results Flexible ending criteria to ensure accurate test results Adheres to 21CFR Part 11 SPECIFICATIONS Sample Size 10 mg to 20 g ResoluƟon 1 ppm Moisture Range 10 ppm (or 10 μg water) to 100% Results Display % Moisture, ppm Moisture, or μg Water HeaƟng Range 25-275°C, set in 1°C increments and maintained to ±1°C Test Parameter Memory Storage of up to 102 Programs Warranty Two Years, Factory Parts and Labor (One Year InternaƟonal) Power Requirements 100-120 Volts 50/60 HZ, 1 Amp standby or 8 Amps maximum 220-240 Volts 50/60 HZ 4 Amps maximum CalibraƟon Manual calibraƟon with NIST traceable capillary tubes Repeatability Dependant on sample properƟes and capillary tube technique Typically CV is less than 10% for moisture level greater than 0.1% Typically CV is less than 15% for moisture level below 0.1% ResoluƟon Moisture 1 microgram Weight 19 lbs COMPUTRAC ® Vapor Pro ® Green Moisture Specific Analyzer COMPUTRAC ®

Transcript of COMPUTRAC Vapor Pro - azic.com · Green Moisture Specific Instrumenta on uses Rela ve-Humidity, a...

Page 1: COMPUTRAC Vapor Pro - azic.com · Green Moisture Specific Instrumenta on uses Rela ve-Humidity, a sensor based technology that correlates to Karl Fischer coulometric tra on, to determine

ARIZONA INSTRUMENT LLC3375 N Delaware St | Chandler, AZ

www.azic.com

APPLICATIONS

Agricultural ProductsAutomo veBa eriesBiological ProductsBulk | Intermediate ChemicalsElectronicsExplosivesFine | Specialty ChemicalsInjec on MoldersOils | GreasesPetrochemicalsPetroleum RefineryPlas c RecyclingPolymersPowder Bulk SolidsResin ManufacturingRubber | Plas cs

CERTIFICATIONS

ASTM D7191-05 Standard Test Method for Determina on of Moisture in Plas cs by Rela ve Humidity Sensor

UL Lis ng (U.S. and Canada)CE Cer fica on

Green Moisture Specific Instrumenta on uses Rela ve-Humidity, a sensor based technology that correlates toKarl Fischer coulometric tra on, to determine moisture percentage. The analyzers match in precision andaccuracy, but do not u lize reagents, minimizing consumables (green), and is simple to operate. The casingis suitable for a lab environment, but with the ruggedness and durability suitable for a produc on environment.Our customers also enjoy free loaners, free method development and access to our full service lab over the life me of their instrumenta on.

FEATURES Con nuous display of test me, current temperature, programmed test temperature, current microgram water measurement, and calculated moisture content Sta s cal features calculate mean, standard devia on and rela ve standard devia on Temperatures are programmable; maintained within ±1°C | Temperature Calibra on Interface Real- me graph of moisture curve and rate of moisture loss Easy setup of product methods to ensure op mum test results Flexible ending criteria to ensure accurate test results Adheres to 21CFR Part 11

SPECIFICATIONS Sample Size 10 mg to 20 g Resolu on 1 ppm Moisture Range 10 ppm (or 10 μg water) to 100% Results Display % Moisture, ppm Moisture, or μg Water Hea ng Range 25-275°C, set in 1°C increments and maintained to ±1°C Test Parameter Memory Storage of up to 102 Programs

Warranty Two Years, Factory Parts and Labor

(One Year Interna onal) Power Requirements 100-120 Volts 50/60 HZ, 1 Amp standby or 8 Amps maximum 220-240 Volts 50/60 HZ 4 Amps maximum Calibra on Manual calibra on with NIST traceable capillary tubes

Repeatability Dependant on sample proper es and capillary tube technique

Typically CV is less than 10% for moisture level greater than 0.1%

Typically CV is less than 15% for moisture level below 0.1%

Resolu on Moisture 1 microgram

Weight 19 lbs

COMPUTRAC® Vapor Pro® Green Moisture Specific Analyzer

COMPUTRAC®

Page 2: COMPUTRAC Vapor Pro - azic.com · Green Moisture Specific Instrumenta on uses Rela ve-Humidity, a sensor based technology that correlates to Karl Fischer coulometric tra on, to determine

ARIZONA INSTRUMENT LLC3375 N Delaware St | Chandler, AZ

www.azic.com

COMPUTRAC®

FREE Sample Tes ng

FREE Trials

FREE Loaners

FREE Method Development

Rick Ervin, Director of Sales

800.528.7411 | 602.470.1414

[email protected]

Keely Hughes,

Extended Warran es and Parts

800.528.7411 | 602.470.1414

[email protected]

ACCESSORIES

990-0092 Carrying Case

Y990-0082 External Balance with Cable 110V

Y990-0098 Printer Kit

Y990-0142 Temperature Calibra on Kit 110V

Y990-0143 Dry Air Generator 110V

Y990-0163 Valida on Protocol VP

Y990-0196 VP Comm SW

Y990-0249 Technology Transfer Kit (Binder & CD)

CONSUMABLES

990-0150 1.0 Microliter Microcaps

990-0229 Sample Bo les

Y990-0206 Kit, 50 Septa, 10 Caps, High Temperature

Y990-0226 Bo les (10), Metal Caps (10), Septa (10)

SPARE PARTS

Y990-0116 Dessicant Cylinder, Inline

Revised 30 June 2011