Computer Isobus Rauch

68
OPERATOR MANUAL Please read carefully before using the machine! Store carefully for future use! This Operator Manual should be consi- dered as part of the machine. Suppliers of new and second-hand machines are obliged to indicate in writing that the Operator Manual has been delivered with the machine. Original operating manual 5901200- a -en-0411 ISOBUS ISOBUS AXIS 30.1(W) / 40.1(W) / 50.1W

description

vcv

Transcript of Computer Isobus Rauch

  • OPERATOR MANUAL

    Please read carefullybefore using the machine!

    Store carefully for future use!

    This Operator Manual should be consi-dered as part of the machine. Suppliersof new and second-hand machines areobliged to indicate in writing that theOperator Manual has been deliveredwith the machine.

    Original operating manual

    5901200-a -en-0411

    ISO

    BUS

    ISOBUS

    AXIS

    30.1(W

    ) / 4

    0.1(

    W) /

    50.

    1W

  • Preface

    Dear customerby purchasing the electronic control unit for the AXIS solid fertiliser broadcaster, you have shown that you are putting your trust in our product.Thank you! We want to justify your trust. You have purchased a powerful and reliable electronic control unit. However, if any problems occur: Our Customer Service is always ready to help.

    Please read this operator's manual and the operator's manual for the solid fertiliser broad-caster carefully before operating the control unit and follow all instructions. This operating manual may also contain descriptions of equipment and options that are not includ-ed with the feature package of your electronic control unit.You should be aware that damage caused by incorrect operation or improper use cannot be cov-ered by warranty claims.

    Technical ImprovementsWe are continuously improving our products. For this reason we reserve the right to make any improvements and changes to our machine that we consider necessary without notice. We do not accept any obligation to make such improvements or changes on machines that have already been sold.

    We will be pleased to answer any other questions that you might have.Yours sincerelyRAUCHLandmaschinenfabrik GmbH

    n CAUTION

    Observe the serial number of the electronic control unit and the solid fer-tiliser broadcasterThe electronic control unit is calibrated in the factory to the solid fertiliser broad-caster that is included in the delivery. This cannot be connected to other solid fertiliser broadcasters without additional recalibration.Please enter the serial number of the electronic control unit and the solid ferti-liser broadcaster here.This number must be checked before connecting the electronic control unit to the solid fertiliser broadcaster.

    Serial number Electronic control unit

    Serial number Solid fertiliser broadcaster

    Year of manufacture Solid fertiliser broadcaster

  • Table of Contents

    I

    Preface

    1 User instructions 11.1 About this operator's manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.2 Information on layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

    1.2.1 Meaning of safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.2.2 Instructions and procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.2.3 Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

    1.3 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

    2 Layout and function (CCI 100) 52.1 Overview of the axis versions supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52.2 Layout (CCI 100) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62.3 Connection (CCI 100) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.4 Operating elements and keys (CCI 100) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    2.4.1 overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82.4.2 Selection button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.4.3 Function buttons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102.4.4 Stop switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102.4.5 Rear navigation key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    2.5 Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    3 Attachment and installation 133.1 Tractor requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133.2 Connections, sockets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    3.2.1 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143.3 Connect the electronic control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143.4 Preparation of metering slide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    4 Operation 174.1 Structural overview menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174.2 Switching on the ISOBUS terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184.3 Operating screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194.4 Stop switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224.5 Weighing - Tripcounter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    4.5.1 Trip counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264.5.2 Metre counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284.5.3 Weigh quantity (only weigh spreader) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294.5.4 Machine tare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    4.6 Main menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334.7 Fertiliser settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

    4.7.1 Flow factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374.7.2 Drop point. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384.7.3 Calibration test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

  • Table of Contents

    II

    4.8 Machine settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424.8.1 Operating mode - Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434.8.2 Automatic mode with automatic weighing (AUTO km/h + Auto kg) . . . . . . . 444.8.3 Automatic mode with static weighing (AUTO km/h + Stat. kg) . . . . . . . . . . . 464.8.4 Automatic Mode (Auto km/h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484.8.5 Manual Operation (MAN km/h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494.8.6 Manual Operation Scale (MAN Scale) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494.8.7 +/- appl. rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

    4.9 Fast emptying. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524.10 System / Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

    4.10.1 Test / Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 554.10.2 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

    5 Alarm messages and possible causes 575.1 Meaning of alarm messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 575.2 Fault/Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

    5.2.1 Acknowledging alarm message: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

    6 Special equipment/options 61

    7 Guarantee and warranty 63

  • User instructions

    1

    1

    1 User instructions

    1.1 About this operator's manual

    This operator's manual is component part of the electronic control unit opera-tor's manual.The operator's manual contains important instructions for the safe, correct and economical operation and maintenance of the electronic control unit. Your at-tention will help to prevent dangers, reduce repair costs and downtime and will increase the reliability and service life of the machine being controlled.The operating manual must be kept within reach at the place of operation of the electronic control unit (e. g. in the tractor).The operating manual does not replace the responsibility of the owner and op-erating personnel of the electronic control unit.

    1.2 Information on layout

    1.2.1 Meaning of safety instructions

    The warnings in the operator's manual are classified according to how serious the danger is and the probability of its occurrence.The warning symbols draw attention to the unavoidable residual risks inherent in the design to which users of the electronic control unit are exposed. The safety instructions used are structured as follows:

    Example

    Signal word

    Symbol Explanation

    n DANGER

    Risk to life if warning is disregardedIgnoring this warning will result in very serious injury or death. Read this operating instruction carefully and follow the

    warning advice.

  • User instructions 1

    2

    Danger levels in the warningsThe danger level is identified by the signal word. The danger levels are classified as follows:

    n DANGER

    Type and source of the dangerThis note warns of a danger posing an immediate threat to the health and life of people. Ignoring this warning will result in very serious injury or death. Always observe the measures described to prevent this

    danger.

    n WARNING

    Type and source of the dangerThis note warns of a potentially dangerous situation for personal health. Non adherence to this warning advice leads to serious injury. Always observe the measures described to prevent this

    danger.

    n CAUTION

    Type and source of the dangerThis note warns of a potentially dangerous situation for personal health or of material and environmental damage.Not adhering to these safety instructions leads to product damage or environmental damages. Always observe the measures described to prevent this

    danger.

    NOTICEGeneral instructions include tips for usage and useful information but not warn-ings of dangers.

  • User instructions

    3

    1

    1.2.2 Instructions and procedures

    Steps that the operator must carry out are shown as a numbered list.1. Instruction for action step 12. Instruction for action step 2Instructions that only have one step are not numbered. The same applies for ac-tion steps that do not have a specific sequence.A bullet is placed in front on these instructions: Handling instruction

    1.2.3 Lists

    Lists without a specific sequence are shown as lists with bullet points (level 1) and dashes (level 2): Property A

    - Point A- Point B

    Property B

    1.3 Intended use

    The electronic control unit may only be used for the respective tasks specified in this operating manual.The electronic control unit is only intended for use for agriculture and agricultural work (intended use).Any use other than its intended use is prohibited.The manufacturer is not liable for any damage resulting from misuse; the operator bears all risk.Designated use also includes observing the operating, maintenance and service conditions as prescribed by the manufacturer.The electronic control unit may only be used by those that are familiar with the characteristics of the machines. Information about operation, service and safe handling, as specified by the manufacturer in this operating manual and in the form of safety information and warning symbols on the machines, must be ad-hered to.Unauthorised modifications made to the machines may result in consequential damages and the manufacturer will not accept any liability for such damages

  • User instructions 1

    4

  • Layout and function (CCI 100)

    5

    2

    2 Layout and function (CCI 100)

    2.1 Overview of the axis versions supported

    NOTICE

    This chapter is limited to the layout and function of the ISOBUS CCI 100 termi-nal due to the number of different ISOBUS capable terminals.

    AXIS type 30.1 Q 30.1 W 40.1 Q 40.1 W 50.1 W

    Spreading speed, depending on travelling speed

    Weighing cells

    Electrical application point adjustment

  • Layout and function (CCI 100) 2

    6

    2.2 Layout (CCI 100)

    Figure 2.1: Terminal CCI 100 overview

    No. Designation Function

    1 Stop switch The stop switch shifts the connected device into se-cure mode. See page 10.

    2 Screen Colour screen for displaying all functions.

    3 Selection button For selecting in the menu and input fields.

    4 Keys 19 touch keys for terminal operation. See page 10.

    5 Bracket Terminal installation in the tractor cabin.

    6 USB port with cover

    Protects the USB port from contamination. For data exchange, task controlling and terminal update.

    7 Terminal strip Terminal strip for ISOBUS system cables. See page 7.

    8 Rear navigation key

    Enables functions to be switched from the left to the right side of the screen.See page 11.

    5

  • Layout and function (CCI 100)

    7

    2

    2.3 Connection (CCI 100)

    Figure 2.2: Terminal CCI 100 connections

    NOTICE

    If the terminal should be connected to existing basic ISOBUS equipment, first check compatibility according to international standard ISO 11783 "Tractors and machinery for agriculture and forestry - Serial control and communications data network.Additional information can be found online at www.isobus.net

    No. Designation Function

    1 CAN-1 IN Terminal power supply. ISOBUS communication

    2 CAN-1 OUT ISOBUS communication

    3 Video Standard video signal

    4 Signal Speed signal

    5 RS232 I Optional GPS / Modem

    6 RS232 II Optional GPS / Modem

    7 LIN Currently no function

  • Layout and function (CCI 100) 2

    8

    2.4 Operating elements and keys (CCI 100)

    2.4.1 overview

    CCI 100 operation consists of 18 touch keys (6 strictly-defined and 12 free touch keys) as well as a selection key, a stop switch and a rear function key.

    Figure 2.3: Controls and keys on the CCI 100

    No. Designation Function

    1 Selection button For selecting in the menu and input fields.

    2 Function buttonsF1 - F12

    12 keys with variable functionality, depending on menu icon. See page 10.

    3 ACK key For error message confirmation.

    4 Information key Currently no function.

    5 Double arrow key For switching between the terminal system screens.

    6 Main menu key For switching in the terminal main menu (see man-ufacturer operating manual).

    7 On/Off key Switches terminal on/off.

    !

    1

    2

    34567

    8 9

    2

  • Layout and function (CCI 100)

    9

    2

    2.4.2 Selection button

    The selection button serves for quick navigation in the menu and for entering or editing data in input fields. Turn the selection button to jump between areas that can be selected. Press the selection button to confirm the selection.

    Figure 2.4: Selection button on CCI 100

    8 Stop switch The stop switch shifts the connected device into secure mode. The stop switch is not supported by all ISOBUS terminals. See page 10.

    9 ESC key Entry abort.

    No. Designation Function

  • Layout and function (CCI 100) 2

    10

    2.4.3 Function buttons

    Groups of function keys are vertically arranged on the left and right of the CCI 100 screen. Depending on the terminal model, 1x6 (minimum requirement), 2x5 or 2x6 function keys (like with CCI 100) can be provided.Function key allocation is dependant on the menu icons displayed. Generally, a function is executed by pressing the function key next to the symbol.Function keys that do not have a symbol next to them do not function in the re-spective menu icons.

    2.4.4 Stop switch

    The stop switch switches all connected devices in to secure mode when it is ac-tuated.To release the stop switch, turn this in the arrow direction until the switch springs out.

    Figure 2.5: Stop switch on the CCI 100

  • Layout and function (CCI 100)

    11

    2

    2.4.5 Rear navigation key

    The navigation key on the rear enables switching the allocation of the function keys from the left to the right side of the screen and vise versa.

    Figure 2.6: Rear navigation key

  • Layout and function (CCI 100) 2

    12

    2.5 Screen

    The screen displays the current status information, selection and input options of the electronic AXIS EMC control unit on the terminal.The basic information for operating the solid fertiliser distributor is displayed in the operation icon and the secondary menu icons.

    Screen area

    Figure 2.7: Screen area CCI 100[1] Display area[2] Function button

    NOTICE

    The screen area can vary on different ISOBUS terminals. In the example, the screen area layout of the ISOBUS terminal CCI 100 is shown.

    2

    1

    2

  • Attachment and installation

    13

    3

    3 Attachment and installation

    3.1 Tractor requirements

    Before installing the electronic control unit, check to make sure the tractor fulfils the following requirements: Minimum voltage 11 V is essential at all times, even if multiple consumers

    are connected simultaneously (e.g. air conditioner, lights). The PTO speed can be set to 540 rpm and must be maintained (basic re-

    quirement for correct working width).

    9-pin socket (ISO 11783) on the rear of the tractor for connecting the control unit with the ISOBUS.

    9-pin terminal socket (ISO 11783) for connecting ISOBUS terminals to the ISOBUS.

    NOTICE

    On tractors without load-switchable gears, the ground speed must be selected by using the correct gear ratio in such a way that it corresponds to a PTO speed of 540 rpm.

    NOTICE

    If the tractor does not have a 9-pin socket on the rear, then a tractor installation with a 7-pin socket can be purchased as an optional accessory for the tractor (ISO 11786) and the driving speed sensor.

  • Attachment and installation 3

    14

    3.2 Connections, sockets

    3.2.1 Power supply

    The power supply for the electronic control unit is a 9-pin socket on the rear of the tractor.

    3.3 Connect the electronic control unit

    Depending on the equipment, the electronic control unit can be connected to the solid fertiliser broadcaster in different ways. Additional details can be found in the electronic control unit operating manual.

  • Attachment and installation

    15

    3

    Standard schematic terminal diagram:

    Figure 3.1: Schematic ISOBUS terminal diagram (machine cable)[1] ISOBUS device connector[2] Device control[3] Machine socket[4] Weighing cell right[5] Metering slide actuator, right[6] Empty signal sensor, right[7] Telimat sensor, upper[8] Actuator drop point[9] Telimat actuator[10] Telimat sensor, lower[11] Empty signal sensor, left[12] Actuator metering slide, left[13] Weighing cell left

    AGPL

    1

    2

    3

    4

    5

    6

    710

    11

    12

    13

    9

    8

  • Attachment and installation 3

    16

    3.4 Preparation of metering slide

    The AXIS 20.1 Q, AXIS 30.1 W, AXIS 30.1 Q, AXIS 40.1 W, AXIS 40.1 Q and AXIS 50.1 W solid fertiliser spreaders have an electric slide control for adjusting the spreading volume.

    Figure 3.2: Preparation of the metering slide (example)

    n CAUTION

    Observe the position of the metering slideOperation of the actuators via the ISOBUS terminal can cause damage to the metering slide if the stop levers are incorrectly posi-tioned. Always clamp the stop lever at the maximum position on

    the scale.

    NOTICE

    Follow the solid fertiliser spreader operating manual.

  • Operation

    17

    4

    4 Operation

    4.1 Structural overview menu

    NOTICE

    The operator's manual describes the functions of the electronic control unit as of software version 1.10.00.

    Fert

    ilize

    r Set

    tings

    Hop

    per c

    onfig

    urat

    ion

    Fast

    em

    ptyi

    ngSy

    stem

    / Te

    st

    Mai

    n M

    enu

    Wei

    gh q

    uant

    ity

    Met

    re-c

    ount

    er

    AU

    TO /

    MA

    N m

    ode

    +/- a

    ppl.

    rate

    Test

    /Dia

    gnos

    is

    Ser

    vice

    en

    Mac

    hine

    tare

    kg le

    ft (k

    g, h

    a, m

    )Tr

    ip c

    ount

    er (k

    m/h

    )

    Wei

    ghin

    g-Tr

    ipco

    unte

    r

    Tota

    l dat

    a co

    unte

    r

    Info

    set

    tings

    MA

    N s

    cale

    MA

    N k

    m/h

    Forw

    ard

    spee

    d A

    uto

    App

    licat

    ion

    rate

    (kg/

    ha)

    Wor

    king

    wid

    th (m

    )

    Flow

    fact

    or

    Cal

    ibra

    tion

    star

    t

    Telim

    at b

    orde

    r

    Telim

    at Q

    uant

    ity

    Ferti

    lizer

    Way

    to s

    prea

    d

    Dis

    c ty

    pe

    Dro

    p po

    int

    PTO

    Hei

    ght s

    ettin

    gs

    Com

    posi

    tion

    Man

    ufac

    ture

    r

  • Operation 4

    18

    4.2 Switching on the ISOBUS terminal

    Requirements: The electronic control unit is connected correctly to the solid fertiliser spread-

    er and to the tractor (for an example, see chapter 3.3: Connect the electronic control unit, page 14).

    The voltage is at least 11 V.

    Switch on:

    Figure 4.1: Operating screen

    n CAUTION

    Risk of injury from discharged fertiliserOnly for mineral fertiliser spreaders equipped with electronic con-trol units.In the event of faults, the metering slide could open unexpectedly en route to the spreading location. There is a danger of people slipping on the discharged fertiliser and injuring themselves. Before setting off to the spreading location, you must

    switch off the electronic control unit.

    Press and hold the ISOBUS terminal ON/OFF key. After a few seconds, the start interface appears on the

    electronic control unit. The boot menu is displayed shortly thereafter. Then the operating screen appears.

  • Operation

    19

    4

    4.3 Operating screen

    The settings for spreading work are displayed on this operating screen. Additional sub-menus of the electronic control device can be accessed via different function keys (see page 21).

    Figure 4.2: Operating screen - Areas[1] Selected operating mode[2] Metering slide opening status[3] Position of the metering slide, right[4] Quantity change right[5] Current application rate from the fertiliser settings or the task controller[6] Selection display type[7] Solid fertiliser spreader display[8] Quantity change, left [9] Position of the metering slide, left[10] Drop point position (only appears with electric drop point setting)

    1

    9

    7

    8

    10

    6

    4

    5

    3

    2

  • Operation 4

    20

    Display config.The display field in the operating screen of the electronic control unit [Position [6], Figure 4.2] can be individually adjusted. You can assign three display fields with the following values if desired: km/h (ground speed) FF (flow factor) ha rest (possible area where remaining fertiliser can be spread over) ha trip (area covered since the last time the trip counter was cleared) kg trip (volume spread since the last time the trip counter was cleared) m trip (spread distance since the last time the trip counter was cleared) kg rest (remaining fertiliser) m rest (possible distance where the remaining fertiliser can be spread)1. Select the desired display field via the electronic control unit navigation. The possible displays are listed in the display.

    2. Select a new value that should be displayed in the display field and confirm with OK.

    The new value is entered in the selected display field.

  • Operation

    21

    4

    Function key in the operating screen

    - Switch between the main menu and the current operating screen via the main menu function key.

    - The weighing-trip counter can be accessed via the Trip counter menu.

    - Start or stop regulating the application rate via the Start/Stop function key.

    - Select either the left, the right or both spreading discs via the L%R% function key, through which increased/reduced volumes should be spread.

    - The application rate can be increased to a maximum in-creased volume (set at +10% per step in the example) via the +X% function key.

    - The application rate can be increased to a minimum in-creased volume (set at -10% per step in the example) via the -X % function key.

    - The increased/reduced volume can be reset to the previ-ous basic volume via the 100% function key.

    - The spreader function can be activated/deactivated via the Telimat function key.When activated, the set volume is au-tomatically limited to the right spreading disc to a freely se-lectable volume.

    - Spreading fertiliser can be switched on/off on the left spreading disc via the Part width left function key.

    - Spreading fertiliser can be switched on/off on the right spreading disc via the Part width right function key.

  • Operation 4

    22

    4.4 Stop switch

    The stop switch switches all connected devices in to secure mode when it is ac-tuated.To release the stop switch, turn this in the arrow direction until the switch springs out.

    Figure 4.3: Stop switch on the CCI 100Case 1 - Spreader operationWhile using the stop switch during spreader operation,

    - the metering slide is closed,- the AGP actuator is stopped- and the Telimat actuator is stopped.

    Case 2 - No spreader operationWhen spreader operation is not active, all functions are stopped and the metering slides remain open.

    In both cases, an alarm message is displayed on the ISOBUS terminal display when the stop switch is actuated.

    n CAUTION

    Risk of injury due to spreading discs.Spreading discs are not stopped. Switch off the tractor PTO shaft. Additional information can

    be found in the tractor operating manual.

  • Operation

    23

    4

    Figure 4.4: Isobus stop alarm message[1] Display area

    1. Correct the cause of the alarm message.2. Release the stop switch.After the stop switch has been released, another alarm message is displayed on the ISOBUS terminal display.

    Figure 4.5: Acknowledge Isobus stop alarm message[1] Display area[2] ACK function key

    1

    1

    2

  • Operation 4

    24

    Acknowledging alarm message:

    3. Press the ACK function key.

    NOTICE

    Alarm messages must be acknowledged, since all of the electronic control unit functions are blocked. If the electronic control unit is switched off and then back on during an alarm message, a new alarm message appears in the ISOBUS ter-minal display.

  • Operation

    25

    4

    4.5 Weighing - Tripcounter

    In this menu you can have the values of the spreading work carried out displayed and you can perform functions for the weighing operation.

    Figure 4.6: The Weighing-Tripcounter menu

    1. Press the Weighing - Trip counter function key on the operat-ing screen. The Weighing - Trip counter menu is accessed.

    Submenu Meaning Description

    Trip counter Display of the spread volume, area spread and spread distance.

    page 26

    Metre counter Display of the distance travelled since the last reset of the metre counter.

    Resetting (zeroing) by pressing the 100% function key

    Weigh quantity1

    1. The menu item only appears on the display if the solid fertiliser spreader used is a weighing spreader.

    Weigh volume menu appears. page 29

    Machine tare1 Weigh value set to "0 kg". page 31

  • Operation 4

    26

    4.5.1 Trip counter

    The values for the spreading work that was performed can be accessed in this menu, the remaining volume can be monitored and the trip counter can be reset by clearing it.You can switch to the Trip counter menu and read the current values during spreading, i.e. with open metering slides.

    Figure 4.7: Trip counter menu[1] Spread volume, area and distance display fields[2] Display fields of areas and distances where the remaining fertiliser volume can be

    spread.[3] Remnant data[4] Clearing trip counter

    Trip counterIn the Trip counter section, the following values since the previous clearing can be viewed:

    - Spread amount (kg)- Spread area (ha)- Spread distance (m)

    1. Press the Weighing - Trip counter function key on the oper-ating screen. The Trip counter menu appears.

    NOTICE

    If you should wish to constantly observe the values during the spreading proce-dure you can also assign the freely selectable display fields on the operating screen with kg Trip, ha Trip or m Trip, see: Display config., page 20.

    4

    2

    1

    3

  • Operation

    27

    4

    kg left

    In the kg left section, you can access the remaining fertiliser volume in the hopper. The menu shows the possible area (ha) and distance (m) that the rem-nant fertiliser can be spread over.

    Entering the remaining fertiliser volume when refilling (not with weigh spreaders AXIS 30.1 W, 40.1 W and 50.1 W)1. Fill the hopper.2. Enter the total weight of the fertiliser in the hopper in the section Rest (kg). The device calculates the values for areas and distances that can be

    spread.

    NOTICE

    The current load weight can only be determined in the weighing spreader by weighing. In all other spreaders the remaining fertiliser volume is calculated from the fertiliser and machine settings and from the travelling signal and the in-put of the filling volume must be made manually (see below).The values for application rate and working width cannot be changed in this menu. They are for information only.

    3. Press the back function key or press the main menu function key to return to the operating screen.

  • Operation 4

    28

    4.5.2 Metre counter

    The distance driven since the last time the metre counter was reset is displayed and can be reset in this menu.

    Figure 4.8: Metre counter menu[1] Metres driven display

    1. Press the metre counter function key on the Weighing - me-tre counter menu. The metre counter menu appears.

    1. Press the 100% function key. The metre counter is reset.

    1

  • Operation

    29

    4

    4.5.3 Weigh quantity (only weigh spreader)

    In this menu you can weigh the fertiliser volume contained in the hopper and set the parameters for controlling the flow factor.

    Figure 4.9: The weigh quantity menu[1] Information about the solid fertiliser spreader[2] Current weight display

    Take the following in to account while weighing the volume: The solid fertiliser spreader must be positioned carefully and evenly and may

    not be laid down. The PTO drive shaft must be switched off.

    NOTICE

    The weigh remnant function can only be accessed: if it concerns a weigh spreader with the solid fertiliser spreader being used. if the machine is stopped. if the system is in Auto km/h + Auto kg or Auto km/h + stat. kg operating

    modes (the default mode during delivery of the electronic control unit is Auto km/h + Auto kg mode).

    2

    1

  • Operation 4

    30

    Weighing the volume in the hopper

    3. Fill the hopper. A window appears in the display which shows the remaining fertiliser vol-

    ume.4. Highlight the type of filling carried out on the display:

    - New fertiliser: Flow factor set to 1.0 and a new flow factor regulation will follow.

    - Refill: Continue spreading with the same fertiliser.- Weigh remnant: Only weigh remnant in AUTO km/h and stat. kg mode.

    Flow factor is recalculated.- ESC Quit

    This returns you to the operating screen.

    Working with the weighed fertiliser volume, refilling the hopper:1. Tare the scales.

    See 4.5.4: Machine tare, page 31.2. Select the fertiliser type.

    See 4.7: Fertiliser settings, page 34.3. Fill the hopper.4. Weigh the fertiliser volume in the hopper.

    See 4.5.3: Weigh quantity (only weigh spreader), page 29.5. Start the work. If the hopper goes empty, refill it. To do so, repeat steps 2 to 5.

    If the hopper is empty and is filled with less than 200 kg of fertiliser, the flow factor is fixed and flow factor regulation does not take place. Switch to Auto km/h operating mode and perform a calibration test.

    If the hopper is partially full and if less than 200 kg of fertiliser is added, push the kg button and Weigh Volume on the control panel.

    1. Press the Weighing - Trip counter function key on the oper-ating screen. The Weighing - Trip counter menu is accessed.

    2. Press the weigh function key in the Weighing - Trip counter-menu. The weigh menu is accessed.

    NOTICE

    In order to display the remaining fertiliser volume on the operating screen, the display option kg left must be selected (see: Display config., page 20).

  • Operation

    31

    4

    4.5.4 Machine tare

    Set the weigh values to 0 kg with an empty weigh spreader in the machine tare menu.

    Figure 4.10: Tare Scales menu

    Take the following in to regard while taring the scales: The hopper must be empty. The solid fertiliser spreader has to be positioned carefully and evenly and

    may not lay. he PTO drive shaft has to be switched off. The tractor must be stopped.

    NOTICE

    The machine tare menu item can only be accessed with AXIS 30.1 W, AXIS 40.1 W and AXIS 50.1 W (weigh spreader) solid fertiliser spreaders.

    NOTICE

    Tare the scales before each use in order to ensure problem-free calculation of the remaining fertiliser volume.

    Machine tare:1. Press the Weighing - Trip counter function key on the oper-

    ating screen. The Weighing - Trip counter menu is accessed.

    2. Press the machine tare function key. The Tare scales menu is accessed.

  • Operation 4

    32

    3. Select the machine tare entry. The value for kg is set to 0.

    4. Press the Back function key or press the Main menu function key to return to the operating screen.

  • Operation

    33

    4

    4.6 Main menu

    Figure 4.11: Main menu with submenus

    Press the main menu button on the operating screen. The main menu is accessed where possible submenus are

    displayed.

    Submenu Meaning Description

    Fertiliser settings Settings for fertiliser and spreader opera-tion.

    page 34

    Hopper configura-tion

    Solid fertiliser spreader settings. page 42

    Fast emptying Access to the menu for fast emptying of the fertiliser spreader.

    page 52

    System / Test Electronic control unit settings. page 54

    Info settings Display of the current machine option sta-tus. Machine option changes are only to be made by trained personnel.

  • Operation 4

    34

    4.7 Fertiliser settings

    In the fertiliser settings menu, settings are made for the fertiliser and spreading.

    Figure 4.12: Fertiliser settings menu - Tab 1 and 2

    Figure 4.13: Menu Fertiliser settings - Tab 3 and 4[1] Fertiliser name [2] Type of fertiliser [3] Manufacturer [4] Composition

    Select the fertiliser settings entry in the main menu. The fertiliser settings menu is accessed, where possible

    submenus are organised in tabs.

    Return to main menu via the main menu symbol.

    1

    2

    3

    4

  • Operation

    35

    4

    You can switch between tabs via the page forward and page back function keys. Optionally, the respective tab can be opened by selecting the respective number.

    Input field Submenu Meaning/Possible values

    Description

    Fertiliser name Fertiliser designation.(Data is for informa-tion purposes only)

    Enter in separate in-put windows.

    Application rate Nominal value of ap-plication rate in kg/ha

    Enter in separate in-put windows.

    Working width Determination of the working width to be spread.

    Enter in separate in-put windows.

    Flow factor Input flow factor of the fertiliser used

    Enter in separate in-put windows.page 37

    Drop point Input of drop point only with electric drop point adjustment (AXIS 50.1)

    Enter in separate in-put windows.page 38Follow the solid ferti-liser spreader operat-ing manual.

    Spreading disc type

    Setting the type of spreading discs mounted on the solid fertiliser spreader.(Data is for informa-tion purposes only)

    Selection list: S2 S4 S6 S8 S10 S12

  • Operation 4

    36

    PTO shaft Input of the desired nominal speed of the drive shaft.(Data is for informa-tion purposes only)

    Enter in separate in-put windows.

    Telimat quantity Pre-setting the vol-ume reduction when border fertilising.(Data is for informa-tion purposes only)

    Enter in separate in-put windows.

    Telimat border Storing the Telimat settings for edge ferti-lisation.(Data is for informa-tion purposes only)

    Enter in separate in-put windows.

    Mounted height Setting the specified distance of the solid fertiliser spreader from the ground.

    Selection list (data in cm front/cm rear): 0/6 40/40 50/50 60/60 70/70 70/76

    Way to spread Select the desired type of fertiliser, or-ganise according to normal fertilising or late fertilising, yield optimised boundary spreading.(Data is for informa-tion purposes only)

    Selection list: Normal Normal border Normal boundary Late Late border Late boundary

    Manufacturer Fertiliser manufactur-er(Data is for informa-tion purposes only)

    Enter in separate in-put windows.

    Chemical composi-tion

    Chemical composition of the fertiliser.(Data is for informa-tion purposes only)

    Enter in separate in-put windows.

    Input field Submenu Meaning/Possible values

    Description

  • Operation

    37

    4

    4.7.1 Flow factor

    The desired flow factor can be set in this selection. If you know the flow factor from earlier calibration tests or from the fertiliser chart, you can enter it manually in this selection.

    The flow factor can be determined via the weighing system with the weighing spreader. Data can also be entered manually.

    Calibration start Request submenu for executing the calibra-tion test.

    Composition Percentage content of the chemical compo-sition.

    Input field Submenu Meaning/Possible values

    Description

    NOTICE

    Calibration (page 39) permits the flow factor to be determined and entered with the aid of the electronic control unit.

    NOTICE

    The flow factor calculation depends on the operating mode used. For further information about the flow factor, refer to section 4.8.1: Operating mode - Overview, page 43.

    NOTICE

    The flow factor is within the range of 0.4 to 1.9. The following applies under the same basic conditions (km/h, working width, kg/ha): If the flow factor is increased the metering weight is reduced. If the flow factor is reduced the metering weight is increased.

    NOTICE

    If your fertiliser is not listed in the fertiliser chart, input flow factor 1.00.We highly recommend performing calibration in AUTO km/h operating mode in order to precisely determine the flow factor for this fertiliser.

  • Operation 4

    38

    4.7.2 Drop point

    The drop point setting can only be performed with the AXIS 50.1 W with electric drop point adjustment

    Entering the drop point:

    2. Determine the position for the drop point from the fertiliser chart. Enter the val-ue in the input field and confirm it. The new value is saved.

    If the drop point is blocked Alarm 17 appears; see chapter 5: Alarm messages and possible causes, page 57.

    NOTICE

    On the solid fertiliser spreader AXIS 50.1 W (operating mode Auto km/h + Auto kg), we recommend displaying the flow factor on the operating screen (see: Display config., page 20) in order to observe the flow factor regulation dur-ing spreading.

    1. Select the drop point entry in the Fertiliser settings menu. An input window appears on the display.

    n CAUTION

    Danger of injury caused by automatic adjustment of the drop pointThe move to drop point alarm is displayed with the solid fertiliser spreader AXIS 50.1 W.After actuating the Start/Stop button, the drop point is automatically approached using the electrical setting cylinder to the pre-set value. This can result in injury. Before actuating the Start/Stop, function button, ensure

    that no one is in the danger area of the machine.

    NOTICE

    Emergency actuation on the AXIS 50.1 must not stop the adjustment of the drop point. Otherwise the setting unit for the drop point can suffer damage.

  • Operation

    39

    4

    4.7.3 Calibration test

    The flow factor is calculated on the basis of a calibration test and saved in the electronic control unit in this menu.Run the calibration test: Before spreading for the first time. If the fertiliser quality has changed greatly (moisture, high dust content,

    cracked grain). If a new type of fertiliser is being used.The calibration test must be conducted (with engaged PTO shaft) at a standstill or during travel over a test section. Remove both spreading discs and move the drop point to calibration position

    (AGP 0) (performed automatically via electric drop point adjustment).

    NOTICE

    On the weighing spreader the calibration test menu is blocked in the AUTO km/h + Auto kg operating mode; the menu point cannot be selected.

    n WARNING

    Risk of injury when performing the calibrationRotating machine components and discharged fertiliser may cause injury. Before starting the calibration test make sure that all

    requirements have been met. Follow the Calibration sec-tion in the operating manual for the fertiliser spreader.

  • Operation 4

    40

    Running calibration test

    2. Enter the average work speed and select next.This value is required for calculating the slide position during the calibration test.

    3. Set the spreading width that should be used during the calibration test.

    Select the calibration test entry in the main menu. The alarm Move to drop point is displayed with the

    AXIS 50.1 W.

    n CAUTION

    Danger of injury caused by automatic adjustment of the drop pointOn the AXIS 50.1 W the alarm Move to drop point is displayed. After actuating the Start/Stop button, the drop point moves to the calibration test position (AGP 0). After the calibration test the drop point is approached automatically by means of an electrical set-ting cylinder. This can result in injury. Before actuating the Start/Stop button, ensure that no one

    is in the danger area of the machine.

    1. Start the move to drop point by confirming alarm via the Start/Stop button.

    - Press the spreading width left button to select the left spreading side and/or

    - press the spreading width right button to select the right spreading side.

    4. Start the calibration test by pressing the Start/Stop button. The opening slide of the previously selected part width is

    opened. The calibration test is started.

  • Operation

    41

    4

    5. In order to end the calibration test, press the Start/Stop key again. The opening slide is closed. The Input collected weight menu is displayed.

    6. Weigh the spread fertiliser amount.7. Enter the weight of the discharged fertiliser via the input field in the dis-

    charged volume section and confirm it. A new flow factor appears in the display.

    8. Specify the flow factor.To accept the newly calculated flow factor press the confirm flow factor button.To confirm the previously saved flow factor press the ESC key. The flow factor is saved. The alarm move to drop point is displayed with the AXIS 50.1 W.

    NOTICE

    The calibration test can be stopped at any time by pressing the ESC key. The opening slide is then closed and the Fertiliser Settings menu appears in the display.

    NOTICE

    The calibration test time is not relevant to the accuracy of the results. However, at least 20 kg must be spread.

    n CAUTION

    Danger of injury caused by automatic adjustment of the drop pointOn the AXIS 50.1 W the alarm move to drop point is displayed. After actuating the Start/Stop button, the drop point is automati-cally approached using the electrical setting cylinder to the pre-set value. This can result in injury. Before actuating the Start/Stop button, ensure that no one

    is in the danger area of the machine.

    9. Starting the move to drop point alarm via the Start/Stop but-ton. You will return to the Fertiliser settings menu.

    The calibration test is completed and the flow factor is saved in the electronic control unit.

  • Operation 4

    42

    4.8 Machine settings

    Figure 4.14: Machine settings menu

    Select the Machine settings entry in the main menu. The Machine settings menu is accessed, where optional

    submenus are displayed.

    Return to main menu via the Main menu symbol.

    Input field Submenu Meaning/Possible values

    Description

    Mode Determine Manual (MAN) or Automatic (AUTO) operating mode.

    Selection list: MAN scala MAN km/h AUTO km/hWeighing spreader selection list: AUTO km/h + stat.

    kg page 46 AUTO km/h +

    AUTO kg page 44

    MAN scale Setting manual scale values.(influence of individual operating modes only)

    Enter in separate in-put windows.

  • Operation

    43

    4

    4.8.1 Operating mode - Overview

    By default you operate in AUTO mode. The electronic control unit automatically controls the actuators as specified by the speed signal.Only work in MAN mode if: there is no speed signal (GPS, radar or wheel sensor not available or defec-

    tive), anti-slug pellets or seeds (fine seeds) are to be discharged.

    MAN km/h Setting manual speed.(influence of individual operating modes only)

    Enter in separate in-put windows.

    Speed/signal source

    Selection/limitation of speed signal

    Selection list: Auto speed (auto-

    matic selection of mode or ra-dar/GPS)

    Gearbox Radar/GPS

    +/- appl. rate (%) Pre-setting volume adjustment incre-ments.

    Enter in separate in-put windows.

    Input field Submenu Meaning/Possible values

    Description

    NOTICE

    When working in manual mode you must always operate at a constant ground speed to ensure even spreading.

  • Operation 4

    44

    4.8.2 Automatic mode with automatic weighing (AUTO km/h + Auto kg)

    The AUTO km/h + Auto kg operating mode allows for continuous weighing of the fertiliser volume in the hopper during spreader operation. The regulation of the flow factor is corrected at regular intervals on the basis of this information. This optimises the metering of the fertiliser.

    a) Select Auto km/h + Auto kg:1. Switch on the ISOBUS terminal.2. Switch from the Machine settings menu to the Operating modemenu.3. Select the AUTO km/h + AUTO kg entry from the selection list and confirm

    with OK. The Weigh Volume window appears.

    4. Case a: New fertiliser: The flow factor is reset to 1.0.If necessary, the required flow factor can be

    added later.See 4.7.1: Flow factor, page 37.Case b: Refill: The flow factor setting is retained. The remaining fertiliser volume is increased by the refilling volume.

    5. Highlight the required type of filling and press the Enter key to return to the operating screen.

    NOTICE

    The AUTO km/h + AUTO kg menu only appears on the display if the 50.1 AXIS W solid fertiliser spreader has been configured in the factory.With the AXIS 50.1 W setting, the AUTO km/h + Auto kg operating mode is the default mode from the factory.

    n CAUTION

    Incorrect metering by pressing the ESC keyThe ESC key may not be pressed.Doing so will result in serious errors in the application rate/metering. Always either select new fertiliser or refill to confirm the

    weighing function.

  • Operation

    45

    4

    b) Procedure when spreading with AUTO km/h + AUTO kg:1. Carry out the fertiliser settings:

    Application rate (kg/ha) Working width (m)

    2. Fill the hopper with the fertiliser.

    The Weigh Quantity window appears in the display.3. Highlight the action carried out in the display:

    New fertiliser: Flow factor set to 1.0 and a new flow factor regulation will follow.

    Refill: Continue spreading with the same fertiliser. The flow factor setting is retained.The remaining fertiliser volume is increased by the refilling volume

    ESC Quit The remaining fertiliser volume is increased by the refilling volume.4. Press the Start/Stop button. The spreading starts.

    NOTICE

    If a fertiliser volume of less than 200 kg is filled in an empty hopper, then switch to AUTO km/h + Stat. kg. or AUTO km/h operating mode.

    NOTICE

    The discharge amount has to be spread in under 30 kg/min in AUTO km/h + stat. kg (weighing spreader) or AUTO km/h (other solid fertiliser spreaders) mode on uneven or hilly ground.

    NOTICE

    If, during running (i. e. travelling to the field) a change is made to the fertiliser settings, before starting to spread you must actuate the kg/Weigh Volume but-ton with the vehicle stopped.

    NOTICE

    We recommend that the flow factor be displayed in the operating screen (see : Display config., page 20), in order to watch the flow factor regulation whilst spreading.

  • Operation 4

    46

    4.8.3 Automatic mode with static weighing (AUTO km/h + Stat. kg)

    The AUTO km/h + Stat. kg operating mode is recommended for spreading on uneven hilly terrain and/or for low application rates. Automatic flow factor regula-tion does not take place during spreading. However, you can use the Weigh Remnant function to recalculate the flow factor.

    a) Select Auto km/h + Stat. kg:1. Switch on the ISOBUS terminal.2. Fill the hopper with the fertiliser.3. Leave the machine settings menu.4. Select the AUTO km/h + stat. kg mode in the operating mode input field and

    confirm with OK. The Weigh quantity window appears.

    5. Select a new fertiliser in the input field. The flow factors is reset to 1.0.

    The control unit switches to the operating screen.

    NOTICE

    In the event of problems with the regulating behaviour of the flow factor (block-ages etc.), at a standstill and after resolution of the fault use the Weighing trip counter button in the Weigh Volume Weigh Volume New Fertiliser function.

    NOTICE

    The AUTO km/h + Stat. kg menu only appears on the display if the AXIS W fer-tiliser spreader has been configured in the factory.

  • Operation

    47

    4

    b) Procedure when spreading with Auto km/h + stat. kg:1. Carry out the fertiliser settings:

    Application rate (kg/ha) Working width (m)

    2. Pour the fertiliser in. The Weigh Quantity window appears in the display.

    3. Highlight the action carried out in the display:Refill: Continue spreading with the same fertiliser. All stored values (flow fac-tor) are retained.New fertiliser: Flow factor is reset to 1.0. If necessary, the required flow fac-tor can be added later.

    ESC Quit4. Refer to the fertiliser chart or empirical values for the flow factor and enter it

    manually.5. Press the Start/Stop button. The spreading starts.

    6. Press the Start/Stop button after at least 150 kg of distributed fertiliser.7. Stop the tractor on even ground.

    8. Switch via the weighing trip counter button in the weighing trip counter menu.9. The weigh quantity menu is accessed.10. Highlight the Weigh remnant selection field. The spreading volume is compared to the actual remnant volume in the

    hopper. The flow factor is then recalculated accordingly.

    11. Press confirm flow factor to confirm the recalculated flow factor. Press ESC to use the flow factor that was previously used.

    NOTICE

    Remnant scale may not be selected after filling.

    NOTICE

    The solid fertiliser spreader must be level.

    NOTICE

    If, during running (i. e. travelling to the field) a change is made to the fertiliser settings, before starting to spread you must actuate the kg/Weigh Volume but-ton with the vehicle stopped.

  • Operation 4

    48

    4.8.4 Automatic Mode (Auto km/h)

    a) Select Auto km/h:1. Switch on the ISOBUS terminal.2. Switch from the Machine settings menu to the Operating mode menu.3. Select the AUTO km/h entry from the selection list and confirm with OK. The entry is saved in the ISOBUS terminal.

    b) Procedure when spreading with Auto km/h:1. Carry out the fertiliser settings: Application rate (kg/ha) Working width (m)2. Pour the fertiliser in.3. Carry out a calibration test to determine the flow factor

    or Take the flow factor from the fertiliser chart and enter it manually.

    4. Press the back button in order to return to the main menu or press the main menu button to return to the operating screen.

    4. Press the Start/Stop button. The spreading starts.

    NOTICE

    In order to achieve an optimum spreading result you should carry out a calibra-tion test before starting to spread.

  • Operation

    49

    4

    4.8.5 Manual Operation (MAN km/h)

    1. Switch from the Machine settings menu to the Operating mode menu.2. Highlight the MAN km/h selection field. The Forward speed menu is displayed.3. Input the value for the forward speed during spreading. Confirm the entry with

    OK.

    4.8.6 Manual Operation Scale (MAN Scale)

    1. Switch from the Machine settings menu to the Operating mode menu.2. Highlight the MAN scale selection field. The slide opening menu is displayed.3. Input the scale value for the metering side opening. Confirm the entry with

    OK.

    The metering slide opening can be changed manually during spreader operation in the MAN scale mode.

    Requirement: The metering slides are open (activation with the Start/Stop key). Part widths [1] are activated on the operating screen.

    4. Press the Back button in order to return to the main menu or press the Main menu button to return to the operating screen.

    NOTICE

    For an optimum spreading result in manual mode as well, we recommend using the values for metering slide opening and ground speed in the fertiliser chart.

    4. Press the Back button in order to return to the main menu or press the Main menu button to return to the operating screen.

  • Operation 4

    50

    Figure 4.15: MAN scale operating screen[1] Part widths[2] Metering slide opening value

    5. To change the metering opening, press the following buttons:

    - MAN+ to increase the metering slide opening or

    - MAN to reduce the metering slide opening.

    11

    2

  • Operation

    51

    4

    4.8.7 +/- appl. rate

    The percentage of volume adjustment for normal spreading can be gradually de-termined in this menu.The basis (100 %) is the preset value of the metering slide opening. To adjust the volume, press the following buttons on the operating screen:

    Specifying weight reduction:1. Switch from the Machine settings menu to the +/- volume menu.2. Enter the percentage value by which you wish to modify the spreading vol-

    ume.3. Confirm the entry with OK.

    - +10% to increase the increased volume (in 10 % intervals)

    - -10% to decrease the decreased volume (in 10 % inter-vals)

    - 100% to return to the preset values of the metering open-ing.

  • Operation 4

    52

    4.9 Fast emptying

    The Fast emptying menu can be selected to clean the machine after spreading or to discharge the remaining weight quickly.

    NOTICE

    Before starting fast emptying make sure that all requirements have been met. Please refer to the solid fertiliser spreader operating manual (Emptying rem-nants).

    1. Press the Main menu button on the Operating screen. This returns you to the main menu.

    2. Press the Fast emptying button.

    n CAUTION

    Danger of injury caused by automatic adjustment of the drop pointOn the AXIS 50.1 W the alarm move to drop point is displayed. After actuating the Start/Stop button, the drop point moves to the calibration test position (AGP 0). The drop point is then approached automatically using an electric setting cylinder. This can cause injuries and material damage. Before actuating the Start/Stop button, ensure that no one

    is in the danger area of the machine.

    3. Starting the move to drop point alarm via the Start/Stop but-ton. The Fast emptying menu is accessed.

  • Operation

    53

    4

    4. Set the spreading width that should be used during the fast emptying.

    - Press the spreading width left button to select the left spreading side and/or

    - press the spreading width right button to select the right spreading side.

    5. Start the fast emptying by pressing the Start/Stop button. The opening slide of the previously selected part width is

    opened. Fast emptying is started.

    6. To stop fast emptying, press the Start/Stop button again.

    7. Press the ESC button to return to the main menu or press the main menu button to return to the operating screen.

    n CAUTION

    Danger of injury caused by automatic adjustment of the drop pointOn the AXIS 50.1 W the alarm move to drop point is displayed. After actuating the Start/Stop button, the drop point is automati-cally approached using the electrical setting cylinder to the pre-set value. This can cause injuries and material damage. Before actuating the Start/Stopbutton, ensure that no one

    is in the danger area of the machine.

    8. Starting the move to drop point alarm via the Start/Stop but-ton. You return to the main menu/operating screen.

  • Operation 4

    54

    4.10 System / Test

    You make the test and system settings for the electronic control unit in this menu.

    Figure 4.16: Menu System/Test

    1. Press the Main menu button on the operating screen. This returns you to the main menu.

    2. Press the System/Test button. The System/Test menu is accessed.

    Submenu Meaning Description

    Total data coun-ter

    Display of the total solid fertiliser spreader data.

    Display of total spread quantity in kg spread area in ha spread time in h distance travelled in kmDeleting all data is only per-mitted by service personnel.

    Test / Diagnosis Check of actuators and sensors. page 55

    Service Service settings Password-protected; Only accessible to service per-sonnelpage 56

  • Operation

    55

    4

    4.10.1 Test / Diagnosis

    In the test/diagnosis menu you can monitor the function of certain sensors and actuators.

    n CAUTION

    Risk of injury due to moving machine parts.Machine parts can move automatically during the test. Make sure that no one is near the solid fertiliser spreader

    before the test starts.

    One can switch between tabs vie the Page forward and Page back function keys. Optionally, the respective tab can be opened by selecting the respective number.

    NOTICE

    This menu serves only for information purposes.The list of the sensors depends upon the equipment level of the machine.

    Submenu Meaning Description

    Voltage Checking the operating voltage.

    Slide test points Test for engaging the various position points of the slider.

    Checking the calibration

    Test point drop point

    Engaging the drop point. Checking the calibration

    Diagnosis, actua-tor slider

    Manual actuator process.

    Diagnosis, actua-tor drop point

    Manual actuator process.

    Diagnosis load cells A/D values

    Check of actuators and sensors.

    Diagnosis Telimat sensors

    Checking sensors.

    Diagnosis Telimat electric

    Manual actuator processing.

  • Operation 4

    56

    4.10.2 Service

    Empty signal sen-sor

    Checking sensors.

    Lin settings Checking the drop point and Tel-imat cylinder communication.

    Submenu Meaning Description

    NOTICE

    An input code is required for settings in the Service menu. These settings can only be modified by authorised service personnel.As a general rule, we recommend that all settings in this menu are carried out by authorised service personnel.

  • Alarm messages and possible causes

    57

    5

    5 Alarm messages and possible causes

    Various alarm messages can be displayed on the ISOBUS terminal display.

    5.1 Meaning of alarm messages

    No. Message in display Definition and possible cause

    1 Fault in metering system. The actuator for the metering device can-not reach the set value to be moved to. Blockade No position message

    2 Speed or appl. rate to high. Metering slide alarm The maximum metering opening is

    reached. The set metering volume (+/- amount)

    exceeds the maximum metering open-ing.

    3 Flow factor is outside the lim-its.

    The flow factor has got to be within the 0.40 to 1.90 range. The new calculated or entered flow

    factor is outside the range.

    4 Left hopper empty! The level sensor on the left reports "empty". Left-hand hopper is empty.

    5 Right hopper empty! The level sensor on the right reports "empty". Right-hand hopper is empty.

    8 Minimum spreading quantity 150 kg not achieved. Old fac-tor valid.

    Flow factor calculation not possible. Operating mode Auto km/h + Stat. kg

    is selected. The appl.rate is too low to calculate the

    new flow factor when the remnant is weighed.

    The old flow factor is retained.

    14 Error in Telimat device. Alarm for the Telimat actuator.The actuator cannot reach the target value to be started. Blockade No position message

  • Alarm messages and possible causes 5

    58

    16 Move to drop pointYes = START

    Only for AXIS 50.1 W: Safety request be-fore automatic approach to the drop point. Setting the drop point in Fertiliser set-

    tings menu Fast emptying

    17 Error in drop point setting The actuator for the drop point setting can-not reach the set value to be moved to. Blockade No position message Calibration Test

    18 Drop point setting blocked. The actuator for the drop point setting can-not reach the set value to be moved to. Blockade No position message Calibration test

    19 Drop point setting defective. The actuator for the drop point setting can-not reach the set value to be moved to. No position message

    20 Linbus user error: Name. Communication problem. Defective cable Plug loosened

    21 Spreader overloaded Only for weighing spreader: the fertiliser spreader is overloaded. Too much fertiliser in the hopper

    23 Error in Telimat setting The actuator for the Telimat setting cannot reach the set value to be moved to. Blockade No position message Calibration test

    24 Telimat setting blocked. The actuator for the Telimat setting cannot reach the set value to be moved to. Blockade No position message Calibration test

    25 Telimat setting defective. The actuator for the Telimat setting cannot reach the set value to be moved to. No position message

    No. Message in display Definition and possible cause

  • Alarm messages and possible causes

    59

    5

    5.2 Fault/Alarm

    5.2.1 Acknowledging alarm message:

    An alarm message is highlighted in the display and displayed with a warning icon.

    Figure 5.1: Alarm message (e.g. Hopper empty)

    Acknowledging alarm message:1. Correct the cause of the alarm message.

    Please refer to the solid fertiliser spreader operating manual and section 5.1: Meaning of alarm messages, page 57 for this.

    2. Press the ACK (CCI 100) touch key.

    NOTICE

    Error message confirmation can vary with different ISOBUS terminals.

    !

  • Alarm messages and possible causes 5

    60

  • Special equipment/options

    61

    6

    6 Special equipment/options

    No. Illustration Name

    1 Empty message sensor for AXIS

    2 Ground speed sensor

    3 Telimat Sensor

  • Special equipment/options 6

    62

  • Guarantee and warranty

    63

    7

    7 Guarantee and warranty

    Rauch units are manufactured with modern production methods and with the greatest care and are subject to numerous inspections.Therefore RAUCH offers a 12-month warranty subject to the following conditions: The warranty begins on the date of purchase. The warranty covers material and manufacturing faults. Our liability for third-

    party products (hydraulic system, electronics) is limited to the warranty of the manufacturer of the equipment. During the warranty period manufacturing and material faults are corrected free of charge by replacement or repair of the affected parts. Other rights extending beyond the above, such as claims for conversion, reduction or replacement for damages that did not occur in the object of supply are explicitly excluded. Warranty services are provided by authorised workshops, by RAUCH factory representatives or the factory.

    The guarantee excludes the consequences of natural wear, contamination with dirt, corrosion and all faults caused by inappropriate handling and exter-nal influences. The warranty is rendered void if the owner carries out repairs or modifications to the original state of the object of supply. Warranty claims are rendered void if RAUCH original spare parts were not used. Please follow the directions in the operator's manual. In all cases of doubt contact our fac-tory representatives or the factory directly. Warranty claims must be submit-ted to the factory by 30 days at the latest after occurrence of the problem. The date of purchase and the serial number are required. If repairs under the war-ranty are required, they must be carried out by the authorised workshop only after consultation with RAUCH or the company's appointed representatives. The warranty period is not extended by work carried out under warranty. Shipping faults are not factory faults and therefore are not part of the warranty obligation of the manufacturer.

    No claims for compensation for damages that are not part of the fertiliser spreader itself will be accepted. This also means that no liability will be ac-cepted for damages resulting from spreading errors. Modifications made to the loading wagon or the fertiliser spreader may result in consequential dam-ages and the supplier will not accept any liability for such damages. In the event of intent or gross negligence of the owner or a senior employee and in cases faults in the object of supply cause personal injury or damage to private property the supplier's limit to liability will not apply. It will also not apply in the case of faults in properties that are explicitly assured, if the assurance had the purpose of protecting the purchaser against damage that does not arise from the object of supply itself.

  • 30.1 EMC + W

    Preface1 User instructions1.1 About this operator's manual1.2 Information on layout1.2.1 Meaning of safety instructions1.2.2 Instructions and procedures1.2.3 Lists

    1.3 Intended use

    2 Layout and function (CCI 100)2.1 Overview of the axis versions supported2.2 Layout (CCI 100)2.3 Connection (CCI 100)2.4 Operating elements and keys (CCI 100)2.4.1 overview2.4.2 Selection button2.4.3 Function buttons2.4.4 Stop switch2.4.5 Rear navigation key

    2.5 Screen

    3 Attachment and installation3.1 Tractor requirements3.2 Connections, sockets3.2.1 Power supply

    3.3 Connect the electronic control unit3.4 Preparation of metering slide

    4 Operation4.1 Structural overview menu4.2 Switching on the ISOBUS terminal4.3 Operating screen4.4 Stop switch4.5 Weighing - Tripcounter4.5.1 Trip counter4.5.2 Metre counter4.5.3 Weigh quantity (only weigh spreader)4.5.4 Machine tare

    4.6 Main menu4.7 Fertiliser settings4.7.1 Flow factor4.7.2 Drop point4.7.3 Calibration test

    4.8 Machine settings4.8.1 Operating mode - Overview4.8.2 Automatic mode with automatic weighing (AUTO km/h + Auto kg)4.8.3 Automatic mode with static weighing (AUTO km/h + Stat. kg)4.8.4 Automatic Mode (Auto km/h)4.8.5 Manual Operation (MAN km/h)4.8.6 Manual Operation Scale (MAN Scale)4.8.7 +/- appl. rate

    4.9 Fast emptying4.10 System / Test4.10.1 Test / Diagnosis4.10.2 Service

    5 Alarm messages and possible causes5.1 Meaning of alarm messages5.2 Fault/Alarm5.2.1 Acknowledging alarm message:

    6 Special equipment/options7 Guarantee and warranty

    /ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 150 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 150 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects true /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile (None) /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False