Compressors
-
Upload
sami-ur-rahman -
Category
Documents
-
view
120 -
download
2
description
Transcript of Compressors
![Page 1: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/1.jpg)
1
WELCOME TO THE WONDERFULWORLD OF
PIPING
COMPRESSORS
Valdel Engineers and Constructors, Ltd.
BY: SAMI UR REHMAN
PIPING DEPARTMENT
![Page 2: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/2.jpg)
2
INTRODUCTION OF COMPRESSOR
Compressors are machines which are used to increase the pressure of a gas by mechanically reducing its volume with in its casing.
Closely related to the pumps. Pressure and temperature will increase. Gases are compressible fluid. Process, Chemical reactions that takes place at elevated pressure. Transportation or transmission of gases through pipelines.
![Page 3: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/3.jpg)
3
CLASSIFICATION OF COMPRESSORS
Compressors can be further classified on its working principle Positive displacement compressors. Dynamic compressors.
![Page 4: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/4.jpg)
4
Reciprocating Compressors Reciprocating compressors are machine in which The compressing
element is a piston following a reciprocating (linear) motion in a cylinder.
Temperature is increase due to increase kinetic energy of the molecules.
Generally used for small to medium volume and compress gas to extremely high pressure.
Piston
![Page 5: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/5.jpg)
5
Two Stage Horizontal Reciprocating Compressor
MOTOR
![Page 6: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/6.jpg)
6
Three stage Reciprocating Compressor
Lines Size1 Stage 24”to 18”2 Stage 18”to 12”3 Stage 12”to 10”
![Page 7: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/7.jpg)
7
Compressor DriverGenerally Electrical motors are used for reciprocating compressors these are of two types Synchronous and Induction motor.
Synchronous motor is exactly same as that of rotating magnetic field they are used for higher power and lower RPM.Efficiency of synchronous motor is 94-97 and is better than induction motor.
Electric Motor
![Page 8: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/8.jpg)
8
Auxiliary Equipment It is supplied by compressor vendor as a skid mounted package with
equipments, its internal piping arrangements, controls and instruments. Generally skid consists of these two systems.
Lubrication system Cooling system
Lubrication System Lubrication is lifeline of any rotating machinery. the lube oil system
Contains reservoir, a pair of circulation pump, shell tube coolers and a duplex filter arrangement . The main function of the lubrication are
Minimize friction and to avoid contact between moving parts. Remove heat induced by friction Protect metal from corrosion.
![Page 9: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/9.jpg)
9
Lube oil consolemaintenance
Lube Oil Console
![Page 10: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/10.jpg)
10
Auxiliary Equipment
Lube Oil Skid
![Page 11: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/11.jpg)
11
Use of Lubrication Generally, two oil pumps are provided for lubrication, one
driven by crankshaft is known as main oil pump (MOP) and other driven by separate elective motor is called auxiliary oil pump (AOP).
![Page 12: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/12.jpg)
12
Cooling System
Heat is generated due to compression of the gas friction in the cylinder . The need to provide cooling can be performed with Air Water (open and close water cooling)
Its difficult to control these limits in open system the PH value range of 6.5 to 8.Hardness should be less than 200 ppm.Suspended solids less than 100 ppm.
Its very easy to add additives in close circulationWater- glycol solution which has low freezing point and high boiling point with respect to water use in close circulation.
![Page 13: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/13.jpg)
13
Accessories
Suction Separator Because compressors requires dry gas free of foreign particles,
the inlet gas is passed through suction drum. Its function is to remove oil and condensates from the gas, the principles of operation are Gravity, Impingement, Centrifugal force and Filtration
Pulsation Dampener or Volume Bottle Volume bottles accumulate sufficient volume(5-20 times of
cylinder) of gas to render uniform flow of gas. Pulsation dampers are devices with the internal system capable of
cutting off certain frequencies. The Pulsation dampers must be installed as close to the cylinder as
possible to avoid the possibilities of acoustic resonance between cylinder and device.
![Page 14: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/14.jpg)
14
Suction Separator
![Page 15: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/15.jpg)
15
Pulsation Dampener or Volume Bottle
![Page 16: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/16.jpg)
16
Location and Maintenance
When locating compressors, consideration must be given to Operability Safety Maintenance
RECIPROCATING COMPRESSORS Reciprocating compressors must be mounted close to grade.
Because of the extreme vibration in the piping system.
Compressor foundation elevation depends on these steps
![Page 17: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/17.jpg)
17
Setting Elevations of Reciprocating Compressors
3.Minimum Distance Required to enter the header
Nozzle
![Page 18: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/18.jpg)
18
Proper Access To Valves
Well Ventilated
![Page 19: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/19.jpg)
19
Reciprocating Compressors Arrangement
At Least Two Stairways
![Page 20: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/20.jpg)
20
Reciprocating Compressors Arrangement
Well Ventilated To Prevent Gas Build Up
From Leaks
![Page 21: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/21.jpg)
21
Open Installation And Enclosed Structure
![Page 22: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/22.jpg)
22
Planning For Cylinder Removal
![Page 23: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/23.jpg)
23
Reciprocating Compressors Piping
![Page 24: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/24.jpg)
24
Reciprocating Compressor Piping
Allowable nozzle load Eccentric Reducer with the flat side on the bottom of the pipe to
prevent the accumulation of any liquids Isolation valve with spectacle blind shall be provided in the inlet
and outlet piping Temporary strainers must be used in inlet. Branch connecting shall be minimized or located at near to the
point where the header is anchored. Piping shall be routed as close to grade or to heavy concrete
foundation as possible. Positive displacement machinery shall be equipped with a PRV. Pressure measurement connection complete with isolation valves
shall be provided on the inlet and outlet piping.
![Page 25: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/25.jpg)
25
Reciprocating Compressors Typical Piping
![Page 26: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/26.jpg)
26
Reciprocating Compressor With all
Components
Compressors linebranch
![Page 27: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/27.jpg)
27
Reciprocating Compressor Support
Pipe support must be given special consideration due to the pulsation.
Rigid anchors, to provide lateral stiffness needed to restrain dynamic force
Compressor piping should never be supported from shelter steel work or operating floor.
And must be provided with independent foundation to avoid transmission of vibrations.
![Page 28: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/28.jpg)
28
Reciprocating Compressor Support
![Page 29: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/29.jpg)
29
Centrifugal Compressor Dynamic type compressor are machine in which air or gas is
compressed by the dynamic action of rotating vanes or impeller. Centrifugal compressors are used to handle large volume of gas
to moderating high pressure. Gas enters the machines at the axis of high speed impeller and
discharges radially into a peripheral chamber at high pressure. Centrifugal compressors may have horizontally split or vertically
split casing .
![Page 30: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/30.jpg)
30
Horizontal Split Case Compressor
Vertical Split Case Compressor
![Page 31: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/31.jpg)
31
Centrifugal Compressor
![Page 32: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/32.jpg)
32
Centrifugal Compressor With Lube Oil Console
Lube Oil Console
Centrifugal Compressor
![Page 33: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/33.jpg)
33
COMPRESSOR DRIVES
Electrical motor Steam turbine Gas turbine
Steam Turbine Back Pressure turbines are driven by high pressure steam and do
not require surface condenser. Condensing turbines are usually driven by low pressure steam.
Gas TurbineUsually employed in remote area, where gas is available for fuel.
![Page 34: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/34.jpg)
34
Elevation for Centrifugal Compressors
![Page 35: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/35.jpg)
35
![Page 36: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/36.jpg)
36
![Page 37: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/37.jpg)
37
Auxiliary Equipment For Centrifugal CompressorsAir filtersWaste heat systemLube oil seal oil consoleSurface condensersCondensate pumps
Maintenance & Location of Centrifugal Compressors The oil console is located closely at the turbine end to facilitate a free draining lube oil return to the reservoir . Control panel is located On the operating floor at the driver end The size of the operating floor must be established by allowing clearance of 6 ft all around machine. An access road is required for mobile handling equipment.
![Page 38: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/38.jpg)
38
Grade Mounted Centrifugal Compressor Open-Sided Structure
![Page 39: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/39.jpg)
39
Grade Mounted or Elevated Centrifugal Compressor Open-Sided Structure
![Page 40: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/40.jpg)
40
Grade Mounted Compressor Wall Shelter
![Page 41: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/41.jpg)
41
Elevated Centrifugal Compressor No Shelter
![Page 42: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/42.jpg)
42
Vertical Condensate
Pump
Inlet Air Filter
Gas turbines require large amounts of clean filtered air for operation
Removes the condensate from the hot well in the surface condenser
![Page 43: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/43.jpg)
43
Seal Oil Console
Surface Condenser
Reduce gas or vapor to a liquid by removing heat
![Page 44: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/44.jpg)
44
Waste Heat System
Hot exhaust gas from gas turbines may be used to generate steam or heating the oil and may be used as a heating
medium
![Page 45: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/45.jpg)
45
The operating floor elevation is next established by making the required headroom allowance beneath horizontal pipe run under the floor while allowing the lube oil return header to slope down To its connecting point on the reservoir. The major factor in setting the elevation of the minimum height that satisfy NPSH requirements of the condensate extraction pumps. The straight run requirements of the suction line its could be varies between 3D to 8D.
ELEVATION OF COMPRESSORS
![Page 46: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/46.jpg)
46
Surface Condenser Elevation
![Page 47: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/47.jpg)
47
Elevated Compressor
![Page 48: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/48.jpg)
48
CENTRIFUGAL COMPRESSORS PIPING & SUPPORT
Nozzle allowable loads.Straight run requirements 3D to 8DSuction and discharge piping on bottom entry installations should Preferably be run close to grade.Do not support compressor piping from the compressor foundation structure .Strainer must be installed.All Valves must be accessible ,preferable from grade.Additional flanges for maintenance.Alignment is more easily achieves if adequate field fit up welds are allowed in spools
![Page 49: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/49.jpg)
49
Centrifugal Compressor Inlet & Outlet Nozzles
Lines SizeInlet 84”outlet 42”
Inlet LineOutlet line
![Page 50: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/50.jpg)
50
Straight run requirements
![Page 51: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/51.jpg)
51
Strainer Must Be Installed.
Additional Flanges For Maintenance
![Page 52: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/52.jpg)
52
Valves Must Be Accessible
![Page 53: Compressors](https://reader035.fdocuments.us/reader035/viewer/2022062614/545f12eab1af9f927d8b4cec/html5/thumbnails/53.jpg)
53
QUESTION ??