Compressor FE

2
1 2 3 4 Line Material 5 6 7 8 9 [Note 1] 10 80 80 80 11 12 kPa 13 m 3 /hr 14 15 16 17 18 19 20 m3/hr 21 °C 22 kPag 23 kPag 24 Design Temperature °C 25 kPa 26 kPaa 27 28 cP 29 30 °C 31 32 kg/m³ 33 34 35 36 37 38 39 40 41 42 43 [Note 2] 44 45 Upstream Straight Length Required D 46 Downstream Straight Length Required D 47 48 49 50 51 52 53 54 mm 55 mm 56 57 mm 58 59 60 61 62 63 64 VTA - Vendor to Advice, NA - Not Applicable 65 1. Orifice Plate to be supplied in accordance with BAE Specification 21009-BAE-70000-IN-SP-0009 66 2. Type: Orifice Flange, Weld Neck RF/RTJ 67 3. All Bolts & Nuts shall be Flourocarbon Coated 68 4. Documentation Required to Include : Material Certificates (EN 10204.3.1), Dimensional Drawings and Maintenance Instruction. 69 5. Sizing Calculation shall be submitted for Technical Evaluation by Vendor 70 6. Flange taps shall be vertical for gas or air service and horizontal for liquid service 71 72 73 C2 xx/xx/xxxx DP SVS/MRK RM HH/KK C1 - C0 - 7 Rev B0 - Of Rev Date Prepared Checked Engr Approved 8 N/A N/A Orifice Plate Holder Material Orifice Plate Holder API Ring No. N/A N/A N/A N/A ORIFICE PLATE DATA SHEET GENERAL Tag or Loop Number FE-4321 FE-4392 FE-4341 P & ID Number 21009-BAE-70000-PR-DW-2031 21009-BAE-70000-PR-DW-2041 21009-BAE-70000-PR-DW-2033 Line Number 250-6S-H501 250-6S-H118 150-6A-H045 ASTM A312 316L ASTM A312 316L ASTM A106 Gr B Service C-311A LP Suction Flow (Train A) C-311B LP Suction Flow (Train B) C-321A MP Suction Flow (Train A) Location Skid 1 Skid 1 Skid 1 Quantity One One One Type Concentric Square Edge Concentric Square Edge Concentric Square Edge Line Size / Schedule 250 250 150 Flange Rating / Type ANSI 600# / RF ANSI 600# / RF ANSI 600# / RF Meter Differential Range VTA VTA VTA Flow Range VTA VTA VTA Hazardous Area Classification Zone 2, Group II A/B, T3 Zone 2, Group II A/B, T3 Zone 2, Group II A/B, T3 Eccentric Hole Required NA NA NA SERVICE CONDITION Fluid Hydrocarbon Gas Hydrocarbon Gas Hydrocarbon Gas Flow: Min / Norm / Max Temperature @ Min / Norm / Max Flow Inlet Pressure @ Min / Norm / Max Flow Design Pressure FV / FV / FV / Maximum Pressure Drop Loss Vapour Pressure Molecular Weight / Specific Gravity Viscosity @ Operating Condition Compressibility Factor Minimum Temperature Specific Heat Ratio Cp/Cv Density SPECIAL OPTIONS Meter Type Diff. Pressure Diff. Pressure Diff. Pressure Seal Fluid NA NA NA Seal Fluid Specific Gravity NA NA NA Orifice Plate Material SS316 / L (VTA) SS316 / L (VTA) SS316 / L (VTA) Tap Locations Flange - 2 Sets of Tapping Flange - 2 Sets of Tapping Flange - 2 Sets of Tapping Orifice Flanges 1 Pair 1 Pair 1 Pair Meter Run / Material NA NA NA 10 / VTA 10 / VTA 10 / VTA 5 / VTA 5 / VTA 5 / VTA Orifice Carrier Body / Material ASTM A 182 F316L (VTA) ASTM A 182 F316L (VTA) ASTM A105N (VTA) Wetted Parts : Material SS 316 / L (VTA) SS 316 / L (VTA) SS 316 / L (VTA) Sour Service Specification NACE MR-0175 NACE MR-0175 NACE MR-0175 Vent or Drain Hole Required NA NA NA Orifice Bore Standard BS 4042/ASME/ISO-5167 BS 4042/ASME/ISO-5167 BS 4042/ASME/ISO-5167 Calculation Standard BS 4042/ASME/ISO-5167 - Part I BS 4042/ASME/ISO-5167 - Part I BS 4042/ASME/ISO-5167 - Part I Sizing Mode Exact Bore / Flow Exact Bore / Flow Exact Bore / Flow Line Inside Diameter 242.87 242.87 146.34 Orifice Diameter VTA VTA VTA Beta Ratio ( d / D ) VTA VTA VTA Plate Thickness VTA VTA VTA PURCHASE Supplier VTA VTA VTA Manufacturer VTA VTA VTA Model Number VTA VTA VTA NOTES Project Title Issued for Bid BALNAVES FIELD DEVELOPMENT – SUPPLY OF LEASED FPSO Not Issued Not Issued Data Sheet Number Sheet 21009-BAE-70000-IN-DS-0009 C2 Description Not Issued

description

Restriction Orifice

Transcript of Compressor FE

Page 1: Compressor FE

1

2

3

4 Line Material

5

6

7

8

9 [Note 1]

10 80 80 80

11

12 kPa

13 m3/hr

14

15

16

17

18

19

20 m3/hr

21 °C

22 kPag

23 kPag

24 Design Temperature °C

25 kPa

26 kPaa

27

28 cP

29

30 °C

31

32 kg/m³

33

34

35

36

37

38

39

40

41

42

43 [Note 2]

44

45 Upstream Straight Length Required D

46 Downstream Straight Length Required D

47

48

49

50

51

52

53

54 mm

55 mm

56

57 mm

58

59

60

61

62

63

64 VTA - Vendor to Advice, NA - Not Applicable

65 1. Orifice Plate to be supplied in accordance with BAE Specification 21009-BAE-70000-IN-SP-0009

66 2. Type: Orifice Flange, Weld Neck RF/RTJ

67 3. All Bolts & Nuts shall be Flourocarbon Coated

68 4. Documentation Required to Include : Material Certificates (EN 10204.3.1), Dimensional Drawings and Maintenance Instruction.

69 5. Sizing Calculation shall be submitted for Technical Evaluation by Vendor

70 6. Flange taps shall be vertical for gas or air service and horizontal for liquid service

71

72

73

C2 xx/xx/xxxx DP SVS/MRK RM HH/KK

C1 -

C0 - 7 Rev

B0 - Of

Rev Date Prepared Checked Engr Approved 8

N/A

N/A

Orifice Plate Holder Material

Orifice Plate Holder API Ring No.

N/A

N/A

N/A

N/A

ORIFICE PLATE

DATA SHEET

GE

NE

RA

L

Tag or Loop Number FE-4321 FE-4392 FE-4341

P & ID Number 21009-BAE-70000-PR-DW-2031 21009-BAE-70000-PR-DW-2041 21009-BAE-70000-PR-DW-2033

Line Number 250-6S-H501 250-6S-H118 150-6A-H045

ASTM A312 316L ASTM A312 316L ASTM A106 Gr B

Service C-311A LP Suction Flow (Train A) C-311B LP Suction Flow (Train B) C-321A MP Suction Flow (Train A)

Location Skid 1 Skid 1 Skid 1

Quantity One One One

Type Concentric Square Edge Concentric Square Edge Concentric Square Edge

Line Size / Schedule 250 250 150

Flange Rating / Type ANSI 600# / RF ANSI 600# / RF ANSI 600# / RF

Meter Differential Range VTA VTA VTA

Flow Range VTA VTA VTA

Hazardous Area Classification Zone 2, Group II A/B, T3 Zone 2, Group II A/B, T3 Zone 2, Group II A/B, T3

Eccentric Hole Required NA NA NA

SE

RV

ICE

CO

ND

ITIO

N

Fluid Hydrocarbon Gas Hydrocarbon Gas Hydrocarbon Gas

Flow: Min / Norm / Max

Temperature @ Min / Norm / Max Flow

Inlet Pressure @ Min / Norm / Max Flow

Design Pressure FV / FV / FV /

Maximum Pressure Drop Loss

Vapour Pressure

Molecular Weight / Specific Gravity

Viscosity @ Operating Condition

Compressibility Factor

Minimum Temperature

Specific Heat Ratio Cp/Cv

Density

SP

EC

IAL

OP

TIO

NS

Meter Type Diff. Pressure Diff. Pressure Diff. Pressure

Seal Fluid NA NA NA

Seal Fluid Specific Gravity NA NA NA

Orifice Plate Material SS316 / L (VTA) SS316 / L (VTA) SS316 / L (VTA)

Tap Locations Flange - 2 Sets of Tapping Flange - 2 Sets of Tapping Flange - 2 Sets of Tapping

Orifice Flanges 1 Pair 1 Pair 1 Pair

Meter Run / Material NA NA NA

10 / VTA 10 / VTA 10 / VTA

5 / VTA 5 / VTA 5 / VTA

Orifice Carrier Body / Material ASTM A 182 F316L (VTA) ASTM A 182 F316L (VTA) ASTM A105N (VTA)

Wetted Parts : Material SS 316 / L (VTA) SS 316 / L (VTA) SS 316 / L (VTA)

Sour Service Specification NACE MR-0175 NACE MR-0175 NACE MR-0175

Vent or Drain Hole Required NA NA NA

Orifice Bore Standard BS 4042/ASME/ISO-5167 BS 4042/ASME/ISO-5167 BS 4042/ASME/ISO-5167

Calculation Standard BS 4042/ASME/ISO-5167 - Part I BS 4042/ASME/ISO-5167 - Part I BS 4042/ASME/ISO-5167 - Part I

Sizing Mode Exact Bore / Flow Exact Bore / Flow Exact Bore / Flow

Line Inside Diameter 242.87 242.87 146.34

Orifice Diameter VTA VTA VTA

Beta Ratio ( d / D ) VTA VTA VTA

Plate Thickness VTA VTA VTA

PU

RC

HA

SE

Supplier VTA VTA VTA

Manufacturer VTA VTA VTA

Model Number VTA VTA VTA

NO

TE

S

Project Title

Issued for BidBALNAVES FIELD DEVELOPMENT – SUPPLY OF LEASED FPSO

Not Issued

Not Issued Data Sheet Number

Sheet21009-BAE-70000-IN-DS-0009 C2

Description

Not Issued

Page 2: Compressor FE

1

2

3

4 Line Material

5

6

7

8

9 [Note 1]

10 80 160 160

11

12 kPa

13 m3/hr

14

15

16

17

18

19

20 m3/hr

21 °C

22 kPag

23 kPag

24 Design Temperature °C

25 kPa

26 kPaa

27

28 cP

29

30 °C

31

32 kg/m³

33

34

35

36

37

38

39

40

41

42

43 [Note 2]

44

45 Upstream Straight Length Required D

46 Downstream Straight Length Required D

47

48

49

50

51

52

53

54 mm

55 mm

56

57 mm

58

59

60

61

62

63

64 VTA - Vendor to Advice, NA - Not Applicable

65 1. Orifice Plate to be supplied in accordance with BAE Specification 21009-BAE-70000-IN-SP-0009

66 2. Type: Orifice Flange, Weld Neck RF/RTJ

67 3. All Bolts & Nuts shall be Flourocarbon Coated

68 4. Documentation Required to Include : Material Certificates (EN 10204.3.1), Dimensional Drawings and Maintenance Instruction.

69 5. Sizing Calculation shall be submitted for Technical Evaluation by Vendor

70 6. Flange taps shall be vertical for gas or air service and horizontal for liquid service

71

72

73

C2 xx/xx/xxxx DP SVS/MRK RM HH/KK

C1 -

C0 - 8 Rev

B0 - Of

Rev Date Prepared Checked Engr Approved 8

SS316 / L (VTA)

R-46 (VTA)

Orifice Plate Holder Material

Orifice Plate Holder API Ring No.

N/A

N/A

SS316 / L (VTA)

R-46 (VTA)

Issued for BidBALNAVES FIELD DEVELOPMENT – SUPPLY OF LEASED FPSO

Not Issued

Not Issued Data Sheet Number

SheetNot Issued21009-BAE-70000-IN-DS-0009 C2

Description

NO

TE

S

Project Title

VTA VTA VTA

Model Number VTA VTA VTA

PU

RC

HA

SE

Supplier VTA VTA VTA

Manufacturer

Beta Ratio ( d / D ) VTA VTA VTA

Plate Thickness VTA VTA VTA

Line Inside Diameter 146.34 131.76 131.76

Orifice Diameter VTA VTA VTA

Calculation Standard BS 4042/ASME/ISO-5167 - Part I BS 4042/ASME/ISO-5167 - Part I BS 4042/ASME/ISO-5167 - Part I

Sizing Mode Exact Bore / Flow Exact Bore / Flow Exact Bore / Flow

Vent or Drain Hole Required NA NA NA

Orifice Bore Standard BS 4042/ASME/ISO-5167 BS 4042/ASME/ISO-5167 BS 4042/ASME/ISO-5167

Wetted Parts : Material SS 316 / L (VTA) SS 316 / L (VTA) SS 316 / L (VTA)

Sour Service Specification NACE MR-0175 NACE MR-0175 NACE MR-0175

5 / VTA 5 / VTA 5 / VTA

Orifice Carrier Body / Material ASTM A105N (VTA) ASTM A105N (VTA) ASTM A105N (VTA)

Meter Run / Material NA NA NA

10 / VTA 10 / VTA 10 / VTA

Tap Locations Flange - 2 Sets of Tapping Flange - 2 Sets of Tapping Flange - 2 Sets of Tapping

Orifice Flanges 1 Pair 1 Pair 1 Pair

NA NA NA

Orifice Plate Material SS316 / L (VTA) SS316 / L (VTA) SS316 / L (VTA)

SP

EC

IAL

OP

TIO

NS

Meter Type Diff. Pressure Diff. Pressure Diff. Pressure

Seal Fluid NA NA NA

Seal Fluid Specific Gravity

Density

Minimum Temperature

Specific Heat Ratio Cp/Cv

Viscosity @ Operating Condition

Compressibility Factor

Vapour Pressure

Molecular Weight / Specific Gravity

FV / FV /

Maximum Pressure Drop Loss

SE

RV

ICE

CO

ND

ITIO

N

Fluid Hydrocarbon Gas Hydrocarbon Gas Hydrocarbon Gas

Flow: Min / Norm / Max

Temperature @ Min / Norm / Max Flow

Inlet Pressure @ Min / Norm / Max Flow

Design Pressure FV /

Eccentric Hole Required NA NA NA

Flow Range VTA VTA VTA

Hazardous Area Classification Zone 2, Group II A/B, T3 Zone 2, Group II A/B, T3 Zone 2, Group II A/B, T3

Flange Rating / Type ANSI 600# / RF ANSI 1500# / RTJ ANSI 1500# / RTJ

Meter Differential Range VTA VTA VTA

Type Concentric Square Edge Concentric Square Edge Concentric Square Edge

Line Size / Schedule 150 150 150

Location Skid 1 Skid 1 Skid 1

Quantity One One One

ASTM A106 Gr B ASTM A106 Gr B ASTM A106 Gr B

Service C-321B MP Suction Flow (Train B) C-331A HP Suction Flow (Train A) C-331B HP Suction Flow (Train B)

21009-BAE-70000-PR-DW-2043 21009-BAE-70000-PR-DW-2035 21009-BAE-70000-PR-DW-2045

Line Number 150-6A-H127 150-15A-H071 150-15A-H146

ORIFICE PLATE

DATA SHEET

GE

NE

RA

L

Tag or Loop Number FE-4412 FE-4362 FE-4432

P & ID Number