Complete Insulation System

download Complete Insulation System

of 36

Transcript of Complete Insulation System

  • 8/8/2019 Complete Insulation System

    1/36

    CompleteComplete

    Insulation SystemInsulation System

    Jagdeep Singh Head Sales & Marketing

  • 8/8/2019 Complete Insulation System

    2/36

    Class O Insulation : Professional insulation that preventscondensation and energy losses

  • 8/8/2019 Complete Insulation System

    3/36

    Professional insulation that prevents condensationand energy losses

    Built in vapour barrier prevents condensation

    Reduces energy losses substantially

    Lightweight and flexible, quick and easy

    installation with low maintenance requirements,resulting in time and cost savings

    Excellent resistance to the effects of ozone, oil andchemicals

    FM-Approved

  • 8/8/2019 Complete Insulation System

    4/36

    A SOLUTION FOR IMPROVED IAQ

    Anti Microbial insulation Solutions

  • 8/8/2019 Complete Insulation System

    5/36

    Built-In Anti-Microbial Protection ReducesMould & Bacteria Growth; made with Microban

    Improved Thermal Efficiency: Very Low ThermalConductivity of 0.033 W/m.K @ 00C

    Longer Life: Very High Moisture DiffusionResistance = 10,000

    Fungi Resistance: ASTM G 21

    Bacterial Resistance: ASTM E 2180 / ASTM G 22

    FM Approved

  • 8/8/2019 Complete Insulation System

    6/36

    Foil-faced sheets for the insulation of ducts,storage tanks and pipe work

  • 8/8/2019 Complete Insulation System

    7/36

    Foil-faced sheets for the insulation of ducts,storage tanks and pipe work

    Closed-cell insulation to provide a continuousbarrier to water vapour

    High flexibility for ease of fitting

    Durable and erosion-resistant

    Cleanable and washable, providing a basis forcontinuing system hygiene

  • 8/8/2019 Complete Insulation System

    8/36

    Acoustic Solution :

    Absorption Characteristics

    RISAC Curves:

    RISAC SRL_Logscale.xls

  • 8/8/2019 Complete Insulation System

    9/36

    The high performance sound absorption for a quieter environment

    Sound Absorption

    Open cell structure with engineered pore geometry allows foreffective absorption of air-borne sound across abroadfrequency range

    Sound Transmission Loss Relatively high density and high flow resistance offers

    beneficial sound transmission loss properties

    Vibration Damping and Isolation

    Visco-elastic properties help dampen or deaden resonanceeffects in ducting) which helps to reduce re-radiation effects

    Faster Installation

    Reduces installation time substantially, in comparison

    conventional insulation

  • 8/8/2019 Complete Insulation System

    10/36

    The high performance sound absorption for a quieter environment

    Anti-microbial Resistance

    Built-In Anti-Microbial Protection Reduces

    Mould & Bacteria Growth

    Fungi Resistance: ASTM G 21

    Bacterial Resistance: ASTM E 2180

    Fire

    Class 1, BS 476 Part 7

    UL 94

    Air Erosion

    ASTM C 1071 05

    10,000 fpm (50.8 m/s) NO Erosion!

  • 8/8/2019 Complete Insulation System

    11/36

    The Lightweight and easy to apply insulation covering resistant toscratch & mechanical impact

  • 8/8/2019 Complete Insulation System

    12/36

    The Lightweight and easy to apply insulation covering resistant toscratch & mechanical impact

    Significant reduction in installation cost

    Easy to install - no special tools required

    No risk of galvanic corrosion

    Low maintenance system Resistant to oil & chemicals

    Non metal Cladding system

  • 8/8/2019 Complete Insulation System

    13/36

    The insulation covering resistant to scratch & mechanical impact,with a bright silver finish

  • 8/8/2019 Complete Insulation System

    14/36

    The insulation covering resistant to scratch & mechanical impact,with a bright silver finish

    Bright Silver Finsih

    Easy to Clean

    No risk of galvanic corrosion

    Low maintenance system Significant reduction of installation cost

    Easy to install - no special tools required

    Good resistance to oil, chemicals and damage

    Non metal Cladding system

  • 8/8/2019 Complete Insulation System

    15/36

    Pipe Supports

    Prone for Thermal Bridging

    Leads to Heat Gain & Condensation

  • 8/8/2019 Complete Insulation System

    16/36

    Pipe support and insulation of cold

    applications

    A chain is no stronger than its weakest link

  • 8/8/2019 Complete Insulation System

    17/36

    Pipe support Different solutions

  • 8/8/2019 Complete Insulation System

    18/36

    thermal bridge

  • 8/8/2019 Complete Insulation System

    19/36

    temperature

    gradient

    thermal bridge

    dew point 23C

  • 8/8/2019 Complete Insulation System

    20/36

    Area of problems: pipe brackets

  • 8/8/2019 Complete Insulation System

    21/36

    Area of problems: pipe brackets

  • 8/8/2019 Complete Insulation System

    22/36

    Area of problems: pipe brackets

  • 8/8/2019 Complete Insulation System

    23/36

    Falty gluing

  • 8/8/2019 Complete Insulation System

    24/36

    System solution for Armaflex

    a standard pipesupport bracket is

    fitted around the

    Armafix after it has

    been installed

  • 8/8/2019 Complete Insulation System

    25/36

    Built-In Vapour Barrier Eliminates Thermal Bridging

    INSULATED PIPE SUPPORT

  • 8/8/2019 Complete Insulation System

    26/36

    Built-In Vapour Barrier Eliminates Thermal Bridging

    INSULATED PIPE SUPPORT

    Built-in vapour barrier eliminates thermal bridging

    Excellent de-coupling & isolation performance

    One piece with self-adhesive closure to prevent

    condensation. Installed in three easy steps No compression of insulation thickness

  • 8/8/2019 Complete Insulation System

    27/36

    The Flexible Fire- Stop penetration Seal for pipes

    Protect R 90Protect R 90

  • 8/8/2019 Complete Insulation System

    28/36

    The Flexible Fire- Stop penetration Seal for pipes

    ARMAFLEX Protect R 90

    Intumescent Flexible Elastomeric Insulation. Expandswhen subjected to heat to become a smoke and fire-tightseal.

    Easy to install

    Lightweight

    Water resistant

    Dust & Fibre Free

    Application Area: For pipes

    used HVAC & for Refrigeration applications.

    Wall Burn Through Time: Minimum 90 min. (-R 90)Test according to DIN 4102-11 is equivalent to BS 476 Part 20

    R-90 Brandtest NEW.wmv

    Protect R 90Protect R 90

  • 8/8/2019 Complete Insulation System

    29/36

    Versatile and professional

    ACCESSORIES

  • 8/8/2019 Complete Insulation System

    30/36

    Versatile and professional

    ACESSORIES

    Armaflex Adhesive 520

    Armaflex Tape Self-Adhesive

    Armaflex Gluemaster

  • 8/8/2019 Complete Insulation System

    31/36

    Having Good Insulation is NOT enough

    Any insulation as good as it is installed

    Performance of Insulation

  • 8/8/2019 Complete Insulation System

    32/36

    Application Aspects

    Right Tools

    Housekeeping

    Trained Installers

    Right adhesive

    Follow recommended application Procedure

    Proper Supervision

    Selecting Right Coating for Mechanical / UV protecti

  • 8/8/2019 Complete Insulation System

    33/36

    Certified Installer

  • 8/8/2019 Complete Insulation System

    34/36

  • 8/8/2019 Complete Insulation System

    35/36

    Armaflex

    easy access to the pipe works

  • 8/8/2019 Complete Insulation System

    36/36