Compendium on IR-DRDO Biotoilets for Indian Railways
-
Upload
venkat6299 -
Category
Documents
-
view
274 -
download
0
Transcript of Compendium on IR-DRDO Biotoilets for Indian Railways
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
1/202
1
(Govt. of India)(Ministry of Railways)
COMPENDIUM
on
IR-DRDO BIO-TOILETS
For
INDIAN RAILWAYS
(For official use only)
IRCAMTECH/2012/M/GWL/io!Toile"sApril- 2013
Centre
for
Advanced
Maintenance
MAHARA#$%R& GWALI'R!!00*
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
2/202
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
3/202
2
INDEX
SN Description Page
1. Environment Friendly Toilet Systems. 3-11
2. Performance perameters of Bio-toilets 12
3. Instructions for Pressurised Cleaning of Bio toilets. 12
4. Guidelines for Coaching Depots for Handling of Bacteria. 12
5. List of Cleaning Agents being used in Mechanized Coach Cleaning in
Bio Toilet system.
13
6. Mixing of Cleaning agents before application 14
7. Testing Scheme for Bacteria Culture (Inoculum) & Bio Toilet Effluent. 16-70
8. Minutes of The Meeting held at DRDE on 22.12.2011. 71-73
9. Testing Instruments Specifications and Approximate Cost. 75-82
10. Guidelines for Annual Maintenance and Operation Contract (AMOC).
(No. RDSO/ 2010/CG/ CMI-03 Revision 01) issued in December -2011
83-99
11. Trail/Test Scheme for Field Trail of Bio Toilets (IR-DRDO
Technology) on Indian Railway Passenger Coaches issued by
RDSO/LKO
100-122
12. MOU between DRDO & Railways for joint technology development for
IR-DRDO bio-toilet for IR - Formation of joint Working Group (JWG)
dated 29.03.2010
123
13. Minutes of the meeting with DRDO on 29.05.2012 at Railway Board 124
14. Standards for disposal of waste water from mobile bio-toilets 125
15. Testing Scheme for bio-toilet effluent and Bacteria culture (Inoculum)
for IR
126
16. List of the TOT holders for Bio-digesters & supply of Inoculum for
Railways
127-130
17. Instruction for POH of coaches fitted with IR-DRDE type Bio-Toilets 131-133
18. Procedure for Retro-fitment of DRDE Bio-toilet Tank on ICF/ RCF
Design BG Coaches
134
19. Collection of Effluent Samples 137-140
20. Abstract for Quantities Estimated Approximately for Inoculum
(Bacteria) Generation Facility for 100 M3Plant Capacity.
141-157
21. Bio-Toilet Maintenance Proforma 1& 2. 158-160
22. Source of Supply of Testing Equipment of Effluent of Bio-toilets 161-164
23. Maintenance Instructions on Bio-Toilet System for Coaching DepotStaff
167
24. Provision of Stickers in Bio-Toilets 168
25. P-Trap chokedksfudkyusdh fof/kA 169
26. Welding Failure on Bio-Digester Tank 170
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
4/202
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
5/202
3
SN Description Page
27. Drawing of Inoculum Generation Facility (Cap.100 M3) 173
28. Layout Drawing Showing Bacteria Generation Facility
29. Structural Drawing of Inoculum Generation Facility (Cap.100 M3)
30. Instructions of RLy Board for IR-DRDO Bio-Toilets in Passengercoaches
31. Simplified Procedure- pH test and Total Disolved Solids for Effluent ofBio-Digesters
32. Joint check Report of Bio-Digester Tank in Gorakhpur Workshop
33 Training in Bio-Toilet System
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
6/202
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
7/202
4
Environment Friendly Toilet Systems
Green toilet aims at - Zero-Defecation on the ground
Discharge on track, besides creating environmental issues creates problem inworking to workmen. A multi directional strategy has been implemented for adoption
of Environment friendly toilets on IR passenger coaches. A MOU has been signed
with DRDO for joint technology development. The first prototype rake with bio-toilets
based on the designs developed jointly with DRDO is running successfully in
Bundelkhand express since 18th January 2011. Indian Railways have decided 05
more rakes to be fitted with DRDE technology Bio-toilets from the production of
2011-12 and 2500 more coaches from the production of 2012-13.
Benefits of green toilet Environment friendly
Preventing damages to tracks due to corrosion
Improved aesthetics at Railway Stations
Types of Environment friendly toilets are:
Bio toilets- The Bio toilet system, discharge processed waste on track
Vacuum toilets:Based on the principle of direct transport from the toilet bowl to the tankaided by vacuum creation in the tank and pipeline.
Zero discharge toilet systems:In Zero Discharge toilet system, waste is collected at terminus andthen processed. Solid and liquid separation is done in the tank itselfand liquid is recycled as flush water.
A+,an"a-e of Anaero.ic .io!"oile" i" Mo% i" RE an+ IR
Require less maintenance
Simple in design
Easier Retro fitment on existing coaches in service
Can be in operation upto years together
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
8/202
Working of Biological toilet System ( Anaerobic )
Note : System does not require oxygen and also does not require regular cleaning
Brief about bacteria aerobic/anaerobicAerobic Bacteria
Growth rate of aerobic bacteria is higher
Requires forced aeration and large surface area Large amount of bio-mass is generated Disposal of bio-mass is again an environmental problem
Anaerobic bacteria
Can process doubling its population within 6 to 8 hrs
Dominates and de-compose matter into liquid and gases. Can be kept for 3-4 months at ambient temperature in biodigester tank Can withstand sub zero temperature as well as upto 60 degree
centigrade
Cold temperature would not affect the inside processing becauseAnaerobic process is exothermic in nature & thus in cold regions, heatwill be available inside the chamber because of chemical process.
Advantage of IR-DRDO Bio-Digester
1. No bad smell in toilets from the tanks2. No infestation of Cockroaches & flies
3. Fecal matter in the tank not visible
4. No clogging of digester
5. Effluent is free from off odour and solid waste6. No maintenance required
7. Reduction in organic matter by 90%8. No requirement of adding bacteria/ enzyme
9. No need of removal of solid waste
Human Waste
Anaerobic bacteria(Li uid bacteria)
Liquid waste
Chlorination
Disinfected liquid
discharged to track
Co2! "ethane gases
released to atmosphere
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
9/202
#
IR!R' io!+i-es"er Tan3 for Coaces
Tese "an3s are 4a+e of s"ainless s"eel an+ a,in- folloin- cons"ruc"ional
fea"ures
$he si%e of the tan& is 4' ( 11' ( )2' "" *ith the provision of '4 nos mounting brac&ets
at both the sides along the length of the tan&+ Each brac&et is *ith the provosion of '2 nos+
"1# Si%e bolts *hich are tigten in the under slung on mounting bra&ets+
Main 5ar"s of "e io+i-es"er "an3
1+ Stainless steel tan& *ith '# partition *alls in side the tan&
2+ ,oly grass mats for protection of bacteria in side the *alls+
3+ -all valve *ith handle for operation during emrgency for ma&ing toilet direct
discharge in case of choc&ing+
4+ SS fasteners in place of "S on tan& covers+
+ Stronger bonding of Coloni%ed rubber mat *ith vertical *alls+
I45or"an" i4ensions 6 7olu4e of io+i-es"er Tan3
1+ .ength / 11' mm 2/0idth / )2' mm 3+ eight 4' mm
4+ $otal olume of $an& 4'' lt+ + Effective olume of $an& 3'' it+
#+ Empty $an& *eight 11' 5g+ )+ 6ull $an& 0eight 41' 5g+7+ eight from Rail level /22 mm
11' mm
4' mm
)2' mm
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
10/202
)
Other components of Bio-Digester Tank
1. Mounting Bracket - 04 Nos
2. Safety Rope - 04 Nos
3. Locking Plate - 08 Nos
4. Hex. Head Bolt (M16 X70) - 16 Nos
5. Hex. Nut (M16) - 16 Nos
6. Spring Washer (B16) - 16 Nos
7. Hex. Head Bolt (M8 X35) - 16 Nos
8. U Bracket(8 X20 X38) - 08 Nos
Sketch of Bio-Digester Tank
P-Trap
Manual Slider
Handle
Sampling Port
Mounting
Bracket
Overflow Pipe
Chlorinator
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
11/202
7
ifferen" ,arian"s of io "oile"s
Fea"uresrief +escri5"ion
Pneumatics Electrics PLC Flush
System with flapper valve Yes Yes Yes Pressurized
System with manual slider
valve
no no no gravity
System with reducedopening at inlet
For western style Hindware
commode is proposed
no no no gravity
System with solid liquid
separator
no no no gravity
Variant-IFail safe mode exist- chute system can be operated without dismantling of tank
Variant-2Fail safe mode exist- chute system can be operated without dismantling of tank
PLC= Programmable Logic Controller
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
12/202
8
Variant-3
Fail safe mode does not exist
Variant-4
Fail safe mode exist- chute system can be operated without dismantling of tank
Waste Flow Path
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
13/202
1'
Brief about variant 4 with PLC fitted at ICF
Fea"uresrief +escri5"ion
Pneumatics Electrics PLC FlushSystem with Solid liquid
separator with the provision
of Ball valve.
Yes Yes Yes Pressurized
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
14/202
11
Bio toilets with Ball Valve
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
15/202
12
Bio-Digestar Tank Mounting
Performance Parameters of Bio Toilets:
SN Parameter (as per APHA
Test Method).
Recommended Values for next
six months
Targeted value
(Max.)
1 pH 6 to 9 6 to 9
2 Total Solids Max 750 mg/100 ml 750 mg/100 ml
3 Total Volatile solids Max 500 mg/100 ml 500 mg/100 ml
4 Total Dissolved solids Max 350 mg/100 ml 350 mg/100 ml
5 COD levels Max 2000 MgO2/Lts Max 2000
MgO2/Lts
6 Fecal Coli Forms count 99% Red(Less than 108/100ml)
Performance Parameters Inoculum:
SN. Parameter (as per APHA Test Method). Recommended Values
1. pH 6-9
2. Percentage methane 40-70%
3. MPN for methanogens 103
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
16/202
13
INSTRUCTIONS FOR PRESSURISED CLEANING OF BIOTOILETS:
The preventive maintenance schedule for maintenance of coaches being followed in
IR and time schedule to be followed for maintenance of the IR-DRDO Bio-toilet
system are issued by RDSO under guidelines for AMOC for Bio-toilets (DRDE type).
Maintenance of the Bio-toilet systems and Guidelines for handling of Bacteria
Visual inspection of complete toilets system including under slung
equipments.
Toilet chute to be cleared in bio-toilets if there is chocking.
Checking the toilets system for any deficiency.
Collection and transportation of sample from retention tanks to DRDE,
Gwalior or any other nominated Govt. accredited lab as per the test scheme. Charging of chlorine tables and examination of chlorinator.
Checking of following equipments/repair/replacement for proper functioning:
i. Flapper/slider/ball valve
ii. Leakage in piping, flush system, pneumatics, tank etc. valves,
pressurise, PLC, pneumatic valves, ball valves etc.
iii. Charging of Bio-culture if required (based on test reports).Culture will be
supplied by DRDE/IR
(Issued by the RDSO document no. RDSO/2010/CG/CMI-03(Rev.1)
Guidelines for coaching depots for handling of Bacteria
1. Wear gloves while handling bacterial culture
2. Store bacterial culture in containers with lid which can be closed
3. During transportation lids should be tightly closed.
4. During storage, lids should be kept loose so that the gas generated inside
the container can escape easily otherwise container will get damaged
physically.
5. Do not mix detergents/acids with bacteria at any stage during use.
6. Toilets fitted with bio digesters/ bio toilets should preferably be cleaned by
pressurized water cleaning system so as to minimize the water usage.
7. Clean / sanitize hands with detergents/ soaps after handling of the bacteria.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
17/202
14
List of cleaning agents being used in mechanized coach
cleaning in Bio toilet system
Following cleaning agents are being used for cleaning of bio-toilets in
NCR. These agents are considered to be suitable for IR-DRDO bio
toilets.
Sr.No Locations Name of chemicals used
1 PVC Floor Cleaning Spiral (Johnson Diversey) or Sigla Neutral of Eco Lab
2 Ceramic Toilet fittings
cleaning
Taski R1/Taski R 6 (Johnson Diversey) or Sigla
Neutral of Eco Lab
3 Cleaning agent for
commode pan & wall
protector
Harpic/Retoil/Domex
4 Glass Cleaning Taski R3 (Johnson Diversey) or OC Glass cleaner of
Eco Lab or Collin
5 Laminated Plastic
Sheet & Berth Rexene
cleaner:
Taski R7 (Johnson Diversey) or OC Neutral cleaner
of Eco Lab or Collin
6 Painted Surface Spiral (Johnson Diversey) or Absorbit of Eco Lab or
Collin
7 Stainless Steel Polisher Suma Inox (Johnson Diversey) or Chromol of Eco
Lab or Collin
8 Disinfectant Brands Stride (Johnson Diversey) or Antiback of
EcoLab or Collin or Lizol
Note : Revised specification/alteration brands can be issued by Railways for
achieving better performance.
(Ref: DRM (M)S/JHS Letter No. JHS/ M/ CW/ 130/OBHS dated 26.08.2010 to ED/
CAMTECH)
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
18/202
1
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
19/202
1#
Evaluation of Cleaning Agents provided by Railway
pH % COD
Reduction
Total VFA (mM)S No Treatments Cumulative Biogas
(ml)
42 days 42 days 42 days
1 control 16790 7.61 94.72 1.26
2 Harpic 100 ppm 15820 (94%) 7.54 84.08 1.08
3 Harpic 250 ppm 14750 6.50 76.28 4.70
4 Domex 100ppm 14660 7.23 93.55 0.923
5 Domex 250 ppm 13620 6.33 74.78 2.19
6 Lizol 100 ppm 14340 7.28 85.58 1.83
7 Lizol 250ppm 14250 6.27 58.38 5.00
8 R7 cleaner 100ppm 16030 7.20 77.77 1.22
9 R7 cleaner 250ppm 14210 6.26 45.29 9.16
10 PVC floor cleaner
100ppm
14320 7.31 82.32 1.31
11 PVC floor cleaner
250ppm
14070 (83%) 6.46 62.32 4.94
12 Toilet cleaner 100ppm 15450 7.50 77.92 1.28
13 Toilet cleaner 250ppm 14550 6.51 69.71 3.57
Conclusion: All the six chemicals do not show any deleterious effect on
biodegradation up to 100 ppm during 42 day study period (30 ml/Toilet)
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
20/202
1)
(Govt. of India)
(Ministry of Defence)
DRDE/GWL L.No.: BT/BKB/002/Biodig/2011-12 dated 26.03.2012
RDSO/LKO L.No.: MC/CB/LF/Anaerobic dated 15.05.2012
csDVhfj;k dYpj buksdqye rFkkcsDVhfj;k dYpj buksdqye rFkkcsDVhfj;k dYpj buksdqye rFkkcsDVhfj;k dYpj buksdqye rFkkck;ksck;ksck;ksck;ks&&&&Vk;ysV Vk;ysV Vk;ysV Vk;ysV ,Y;w,Y;w,Y;w,Y;w,,,,UVUVUVUV dh VsfLVax Ldhe dh VsfLVax Ldhe dh VsfLVax Ldhe dh VsfLVax Ldhe
TESTING SCHEME FOR
BACTERIAL CULTURE (INOCULUM)
& BIO TOILET EFFLUENT
j{kk uq!a"kku ,#af#dk! !ax$uj{kk uq!a"kku ,#af#dk! !ax$uj{kk uq!a"kku ,#af#dk! !ax$uj{kk uq!a"kku ,#af#dk! !ax$uDefence R&D Organization
jjjj{kk uq!a"kku ,#af#dk! LFkk%uk{kk uq!a"kku ,#a f#dk! LFkk%uk{kk uq!a"kku ,#af#dk! LFkk%uk{kk uq!a"kku ,#a f#dk! LFkk%uk
Defence R&D Establishmentka!h ekx'(x#kfy;j&ka!h ekx'(x#kfy;j&ka!h ekx'(x#kfy;j&ka!h ekx'(x#kfy;j&)*)++)*)++)*)++)*)++ -kkjr-kkjr-kkjr-kkjrJhansi Road, Gwalior 47400 !"D!#
.wj-kk/kPhone: 91-751-2347545, 3902,2390100
01D!
Fax : 91-751-2341148b'& esye-mail : [email protected]
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
21/202
17
c1c1c1c1DVhfj;k dYpj buksdqyeDVhfj;k dYpj buksdqyeDVhfj;k dYpj buksdqyeDVhfj;k dYpj buksdqyerFkk ck;ksVk;ysV !sck2j fudyus #kysrFkk ck;ks Vk;ysV !sck2j fudyus#kysrFkk ck;ksVk;ysV !sck2j fudyus #kysrFkk ck;ks Vk;ysV !sck2j fudyus#kys%kuh ,Y;wsUV%kuh ,Y;wsUV%kuh ,Y;wsUV%kuh ,Y;wsUVdh VsfLVax djusdh f#f"k;k3dh VsfLVax djusdh f#f"k;k3dh VsfLVax djusdh f#f"k;k3dh VsfLVax djusdh f#f"k;k3
Hkkjrh; jsYos,oavkjMh,lvksdschp gq,s,e-vks-;w dsvk/kkj ij Hkkjrh; jsyksaij
ck;ks VW;ysV dk Vk;y !kjh g"A #l $%kkyh dh l&ku eksuhVfja' ds fy,
vkjMh,lvks(y)ku* dh vk"ipkfjd +ohdfr dsipkr #lsyk'wdjus dsfy, ,d ijh.k%k
ifr fodflr dh ';h g"AjsY#scks4' ds f0kk fu0s1kkuqlkj vkjlh,2 ds 3kjk u, cuk, ',
dkspksadsVk;ysV esack;ksVk;ysV V1ad yxk, 5kusyxs 21a6or1eku esabu V1dksadh %7kjf8-kd
pkf5'ax 9R9E9#kfy;j !sc1DVhfj;k :buksdqye %7kr djus ds%kjk 2h fd,
5kusdsfu.s'
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
22/202
18
dksfpax f4%ksdsfy, dksfpax f4%ksdsfy, dksfpax f4%ksdsfy, dksfpax f4%ksdsfy, ,Y;wsUV,Y;wsUV,Y;wsUV,Y;wsUV %jh{k=k Ldhe %jh{k=k Ldhe %jh{k=k Ldhe %jh{k=k Ldhe
LLLLkk;ksVk;ysV dsV1ad !s fudyus #kyskk;ks Vk;ysV ds V1ad !sfudyus#kyskk;ksVk;ysV dsV1ad !s fudyus #kyskk;ks Vk;ysV ds V1ad !sfudyus#kys,Y;wsUV,Y;wsUV,Y;wsUV,Y;wsUV dhdhdhdh 5k3p 2srq5k3p 2srq5k3p 2srq5k3p 2srq fu8u %jh{k=kfu8u %jh{k=kfu8u %jh{k=kfu8u %jh{k=k %1jk ehVj%1jk ehVj%1jk ehVj%1jk ehVjrFkkrFkkrFkkrFkk %%%%////fr uqeksf.r dh xb' 216fr uqeksf.r dh xb'216fr uqeksf.r dh xb' 216fr uqeksf.r dh xb'216
????MMMM5Hekud %jh{k=kekud %jh{k=kekud %jh{k=kekud %jh{k=k f#LrNr %Ofrf#LrNr %Ofrf#LrNr %Ofrf#LrNr %Ofr;2 %jh{k=k #k;ksVk;ysV V1ad !s fudyus #kys,Y;wsUV dk !s8%y ysdj A!esa%kuhdh p#sY;wdk kdyu fd;k 5krk 21 f5!!s fd ck2j fudyus#kys,Y;wsUV dks.ks/k jf2r cuk;k 5k !ds6GGGGMMMM!a!a!a!aMMMM A%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=k fV%=khfV%=khfV%=khfV%=kh?M %jh{k=k dk A.P.s
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
23/202
2'
5Hekud %jh{k=kekud %jh{k=kekud %jh{k=kekud %jh{k=k !k"kkj=k %Ofr !k"kkj=k %Ofr !k"kkj=k %Ofr !k"kkj=k %Ofr
;2 %jh{k=k #k;ksVk;ysV V1ad !s fudyus #kys,Y;wsUV dk !s8%y ysdj A!esa%kuhdh p#sY;w dk kdyu fd;k 5krk 216
GGGGMMMM!a!a!a!aMMMM A%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=k fV%=khfV%=khfV%=khfV%=kh?M %jh{k=k dk A.P.s
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
24/202
21
#k;ksVk;ysV V1ad !sfudys %kuh esaA%yQ"k dqy !kKfy4 %jh{k=k#k;ksVk;ysV V1ad !sfudys%kuh esaA%yQ"k dqy !kKfy4 %jh{k=k#k;ksVk;ysV V1ad !sfudys %kuh esaA%yQ"k dqy !kKfy4 %jh{k=k#k;ksVk;ysV V1ad !sfudys%kuh esaA%yQ"k dqy !kKfy4 %jh{k=k
MMMM VksVyVksVyVksVyVksVy !kKfy4 %jh{k=k!kKfy4 %jh{k=k!kKfy4 %jh{k=k!kKfy4 %jh{k=k ;2 %jh{k=k #k;ksVk;ysV V1ad !sfudyus#kys,Y;wsUV dk !s8%y ysdj dqy A%yQ"k
!kKfy4P! dh 5k3p djus dsfy, fd;k 5krk 21 f5!!s fd ck2j fudyus #kys ,Y;wsUV
dks.ks/k jf2r cuk;k 5k !ds6GGGGMMMM
!a!a!a!aMMMMA%dj=kksadk f##j=k rFkkA%dj=kksa dk f##j=k rFkkA%dj=kksadk f##j=k rFkkA%dj=kksa dk f##j=k rFkk
fu"kk'fjr !hek,afu"kk'fjr !hek,afu"kk'fjr !hek,afu"kk'fjr !hek,afV%=khfV%=khfV%=khfV%=kh
?M %jh{k=k dk A.P.s
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
25/202
22
d1ydqyskud1ydqyskud1ydqyskud1ydqysku 4-fefefefex7k dqy !kKfy4:?++feyhZx7k dqy !kKfy4:?++feyhZx7k dqy !kKfy4:?++feyhZx7k dqy !kKfy4:?++feyhZ/-=x1'' x1''':!s8%y dk #kKY;we:!s8%y dk #kKY;we:!s8%y dk #kKY;we:!s8%y dk #kKY;we ML52k3 > ZZZZ !qCkk;k x;k %7kr !kKfy4 [ f4
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
26/202
23
TTTTMMMM dqy f45ksY#4dqy f45ksY#4dqy f45ksY#4dqy f45ksY#4 !kKfy4 %jh{k=k!kKfy4 %jh{k=k!kKfy4 %jh{k=k!kKfy4 %jh{k=k f#LrNr %Ofrf#LrNr %Ofrf#LrNr %Ofrf#LrNr %Ofr
!s8%y ds,Y;wsUV esa dqy f45ksY#4 !kKfy4P! dh A%yQ"krk dh 5k3p 2srqb! %jh{k=kdksfd;k 5krk 21f5!!sfd ck2j fudyus#kyk Vk;ysV dk %kuh .ks/k jf2r fd;k 5k
!ds6GGGGMMMM!a!a!a!aMMMM A%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=k fV%=khfV%=khfV%=khfV%=kh?M %jh{k=k dk A.P.s
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
27/202
24
RM ?+".#kKY;we dsf4LVhY4 #kVj !s T ckj !k0 dj1a6 !k0 djrs !e; ";ku jCksafd%7B;sd !0kb' ds.k1jku %kuh %w=k'W% !s4Jsu 2ks5k,6
*M f0YVjsV dks %2ys!srk1yh 2qb'!k0 G;w!h#y esaLFkkukUrfjr dj1aa6 !s8%y dh bruhekEk %7;ksx esaysafd cpk 2qk !kKfy4 yx-kx M !s ++ fex7k dse"; j2s6
XM c G;w!h#y dks2kKV ,;j ks#su esa17'@2oCrd %kuh !wCkusrd !qCkk,a6 4Jkb'2ksusdsck. dejs ds rk%eku rd $=4k djusds fy, b!sf4L!hdsVj esajCksa ,#a0kbuy #5u dksuksV dj1a6
d1ydqyskud1ydqyskud1ydqyskud1ydqysku4-dqy f45ksY#4 !kKfy4:?++ feyhdqy f45ksY#4 !kKfy4:?++ feyhdqy f45ksY#4 !kKfy4:?++ feyhdqy f45ksY#4 !kKfy4:?++ feyhZZZZ/-= x1''x1'''::::!s8%y dk #kKY;we!s8%y dk #kKY;we!s8%y dk #kKY;we!s8%y dk #kKY;we
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
28/202
2
dqy f45ksY#4dqy f45ksY#4dqy f45ksY#4dqy f45ksY#4 !kKfy4 %jh{k=k!kKfy4 %jh{k=k!kKfy4 %jh{k=k!kKfy4 %jh{k=k !k"kkj=k %Ofr !k"kkj=k %Ofr !k"kkj=k %Ofr !k"kkj=k %Ofr
!s8%y ds,Y;wsUV esa dqy f45ksY#4 !kKfy4P! dh A%yQ"krk dh 5k3p 2srqb! %jh{k=kdksfd;k 5krk 21f5!!sfd ck2j fudyus#kyk Vk;ysV dk %kuh .ks/k jf2r fd;k 5k
!ds6GGGGMMMM!a!a!a!aMMMM A%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=k fV%=khfV%=khfV%=khfV%=kh
?M %jh{k=k dk A.P.s
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
29/202
2#
MMMM dqydqydqydqy #ksykVkby#ksykVkby#ksykVkby#ksykVkby !kKfy4 %jh{k=k!kKfy4 %jh{k=k!kKfy4 %jh{k=k!kKfy4 %jh{k=k
!s8%y ds,Y;wsUV esa dqy A%yQ"k #ksykVk;y !kKfy4P! dh A%yQ"krk dh 5k3p 2srqb!%jh{k=k dksfd;k 5krk 21f5!!sfd ck2j fudyus#kyk Vk;ysV dk %kuh .ks/k jf2rfd;k 5k !ds6
GGGGMMMM!a!a!a!aMMMM A%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=k fV%=khfV%=khfV%=khfV%=kh?M %jh{k=k dk A.P.s
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
30/202
2)
MMMMdsfedy kD!h5u f4eka4 %jh{k=kdsfedy kD!h5u f4eka4 %jh{k=kdsfedy kD!h5u f4eka4 %jh{k=kdsfedy kD!h5u f4eka4 %jh{k=k&&&&(Ce4ical '9y-en e4an+ (C')
;2 %jh{k=k ,Y;w,asV esad1fedy kD!h5u f4ekU4 C' dh 5kudkjh %7kr djus2srqfd;k 5krk 21 6GGGGMMMM!a!a!a!aMMMM A%dj=kksa dk f##j=kA%dj=kksadk f##j=kA%dj=kksa dk f##j=kA%dj=kksadk f##j=k fV%=khfV%=khfV%=khfV%=kh
?M %jh{k=k dk A.P.s
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
31/202
27
D. LVs=44'01j! eksfu;e !Y0sV VJkbVsVLVs=44' 01j! eksfu;e !Y0sV VJkbVsVLVs=44'01j! eksfu;e !Y0sV VJkbVsVLVs=44' 01j! eksfu;e !Y0sV VJkbVsV (0:2* M) !87x7ke6e
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
32/202
28
c f"kd 52Cr2' dks 6>S ds!kFk +M?+&+M? feyh &T 4JkK% 0sjksuba4hdsVj dk %7;ksx djrs2q, VkbVJsV djrs 216
c uhys&2js!syky&dBFkb'jax %fj#fr'r 2ksus dh %7fG;k dks .sCksa;h ?feuV ;k f"kd !e; rd j2rk 216
4qyhdsV dksA!dsk1!r ds
rd dsuq%kr esakuk pkf2,6 b!h %7dkj Qysad dUVsfuax jh5sUV dks!s8%y ds cjkcj f4LVhY4 #kVj !s
jhyD! rFkk VkbVJsV djrs216
LVsa44'!ksywS S
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
33/202
3'
RRRRMMMMf0dy dkKyh 0kKf0dy dkKyh 0kKf0dy dkKyh 0kKf0dy dkKyh 0kK8'8'8'8'!!!!
,Y;w,UV esaf0dy dkKyh 0kKe'! #1DVhfj;k dk kdyu djuk6
GGGGMMMM!a!a!a!aMMMM A%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=k fV%=khfV%=khfV%=khfV%=kh?M %jh{k=k dk A.P.s
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
34/202
31
B. 4k;yw
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
35/202
32
kQ5#s'
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
36/202
33
cccc c1DVhfj;k c1DVhfj;k c1DVhfj;k c1DVhfj;k dYpjdYpjdYpjdYpj buksdqyebuksdqyebuksdqyebuksdqye AB%k.AB%k.AB%k.AB%k. dsfy,dsfy,dsfy,dsfy, %jh{k=k Ldhe%jh{k=k Ldhe%jh{k=k Ldhe%jh{k=k Ldhe
ADr ykUV >kjk r1;kj fd, x,ADr ykUV >kjk r1;kj fd, x,ADr ykUV >kjk r1;kj fd, x,ADr ykUV >kjk r1;kj fd, x, #1DVhfj;k#1DVhfj;k#1DVhfj;k#1DVhfj;k dYpjdYpjdYpjdYpj buksdqyebuksdqyebuksdqyebuksdqye %j rFkk ykUV !s %j rFkk ykUV !s %j rFkk ykUV !s %j rFkk ykUV !sAB%Uu ehFksu x1! 2srqfu8u %jh{k=k %AB%Uu ehFksu x1! 2srqfu8u %jh{k=k %AB%Uu ehFksu x1! 2srqfu8u %jh{k=k %AB%Uu ehFksu x1! 2srqfu8u %jh{k=k %////fr uqeksf.r dh xb'216fr uqeksf.r dh xb'216fr uqeksf.r dh xb'216fr uqeksf.r dh xb'216
????MMMM 5Hekud %jh{k=kekud %jh{k=kekud %jh{k=kekud %jh{k=k
;2 %jh{k=k AB%k. esa A%yQ"k %kuh dh p #sY;w dks L%/V djrk 21 f5!!s fdbuksdqye dh A%;qDrrk ,#a LVsfcfyVh dsLrj dk ]ku 2ksrk 216GGGGMMMM!a!a!a!aMMMM A%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=k fV%=khfV%=khfV%=khfV%=kh?M %jh{k=k dk A.P.s
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
37/202
34
MMMM cccck;ksx1! A%yQ"krk 5k3p %jh{k=kk;ksx1! A%yQ"krk 5k3p %jh{k=kk;ksx1! A%yQ"krk 5k3p %jh{k=kk;ksx1! A%yQ"krk 5k3p %jh{k=k &&&&
;2 %jh{k=k buksdqye ykUV dsU.j %1.k 2ksus#kyh x1!ksa dskdyu djusds fy,fd;k 5krk 21f5!!sfd ehFksu x1! %1.k 2ksusdk %7fr
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
38/202
3
TTTTMMMM ehFksu %7fr
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
39/202
3#
MMMM ekbGksf#;yekbGksf#;yekbGksf#;yekbGksf#;y M$@%1jkehVj 5k3p &%1jkehVj 5k3p &%1jkehVj 5k3p &%1jkehVj 5k3p & [ M$@ Coun" for Me"ano-ens]
;2 %jh{k=k buksdqye esa c1DVhfj;k dh A%fLFkfr ,#a Audh uqekfur !aC;k dskdyu dsfy, fd;k 5krk 216GGGGMMMM!a!a!a!aMMMM A%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=kA%dj=kksadk f##j=k fV%=khfV%=khfV%=khfV%=kh?M %jh{k=k dk A.P.s 1000 / MLTM %7;qDr A%dj=k:ehVj G+C+x1! GksesVksx7k0( x1f!ax esuh0ksY4( 2kKV ysV
fLVjj( ysfeuj ,;j yksp18cjbUD;w#sVj( ekbGksf%%sVP!( 21a4 ks%jsfV4 fd7a8% 21a4ks%jsfV4 4hds%j
)M da5wescy !hje #kKVY!( ,Y;wehfu;e fGa8%!( Q;wVkby jcj!sVe( x1! VkbV f!fjU5
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
40/202
3)
=:@ Cons"i"uen"s A4oun" (- / 100 4l)
1 Bitrilo triacetic acid 1+
2 "gSA4+)2A 3+'
3 "nSA4+22A '+
4 BaCl 1+'
CoCl2 '+1
# 6eSA4+)2A '+1
) CaCl2+22A '+1
7 JnSA4 '+1
8 CuSA4+2A '+'1
1' >l5dKust p of Cysteine hydrochloride to 8+'
ba4hdsVj !ksyw
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
41/202
37
RM c ehf4;e dksdejsdsrk%eku rd $U4k dj1a rFkk fj4;wf!ax ,5sUV dh cph2qb'ekEk
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
42/202
38
!a-kkf#r A! kx'u dh ksfjf5uy !s8%y dh D#kufVVh dh !aC;k 2ksxh f5!s,24k;yw
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
43/202
4'
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
44/202
41
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
45/202
42
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
46/202
43
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
47/202
44
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
48/202
4
Testing Scheme for Bio-Toilet Effluent and Bacteria culture(Inoculum)
on Indian Railways
On the basis of MOU between Indian Railways and DRDO, the bio toilet trial on IR
is going on. For intensive monitoring of the system, a test scheme has been
deveopled for implementation after formal approval of RDSO/LKO. As per Railway
Boards guidelines, the bio-toilet tanks i.e. Bio digesters are being fitted in the new
coaches being turned out from RCF. At present, the initial charging of bacteria
culture in the coaches is being done by DRDE/ Gwalior by providing Inoculum in
the barrels. The quality check of the product and bio toilet effluent is also done
according to ALPHA testing methods in DRDE by collecting samples from coachingdepot / Gwalior,
As per Railway Boards guidelines, a 100 M3 capacity Inoculum generation plant is
being developed in the Motibagh workshop in S.E.C. Railway, Nagpur and in
future, similar plants are proposed to be developed in ICF and RCF also. Hence, it
was felt necessary to develop lab sample testing facilities in Railways for doing
minor testings in Railway premises/Railway Labs/ production units & major testings
in Govt. approved labs. To cater the requirement of doing these tests efficiently, it
has also been proposed to provide suitable trainining to Railway staff in liaison with
DRDE sothat proper monitoring can be ensured at approprate level in the zonal
Railways. Some of the minor tests of effluent of bio-toilets have been proposed to
be carried out by coaching depot staff for which procedure has been explained in
detail in this booklet.
The testing scheme for effluent & Bacteria culture(Inoculum) has been tantatively
finalized by DRDE based on the past experience of 12 months trial, which should
be carried out in the existing Railway Labs/ diesel sheds/ coaching depots. The
necessary record of monitoring and testing should also be maintained & kept in the
concerned depots. The critical biological tests which can not be carried out in the
railway labs, such samples may be got tested in govt. labs/ DRDE. The critical
tests which should be carried out in Govt. labs only, has been marked clearly
against the test procedure in the booklet for ready reference.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
49/202
4#
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
50/202
4)
(A) Testing Scheme for Bio-Toilet Effluent in Coaching Depots.
Folowing tests and parameters have been recommended for effluent dischargedafter bio degradation from the bio toilets of coaches in Indian Railways.
1. pH Value Test:
To measure pH value of the effluent of bio toilets to ensure environmentalsafety.
S.No.
Description Details
1. Purpose of test To measure pH value of the effluent of biotoilets to ensure environmental safety.
2. Target value 6 9 pH
3. Equipments required Table top pH meter / Portable pH meter / pHindicator strips & magnetic stirrer
4. Consumables pH calibration buffers (4.0, 7.0, 10.0), andmagnetic stirrer bars
5. Quantity of sample 50-100 ml
6. Electricity requirement Yes
7. Frequency of sampling 90 days
8. Testing spot Railway laboratory9. Staff required 1
Procedure:
First of all, take 02 ltrs. Effluent sample in the bottle from bio-toilet tank.
Take 50 100 ml of mixed effluent sample in a beaker.
Put a magnetic bar and keep the beaker on a magnetic stirrer and switch on themagnetic stirrer to mix it continuously.
Wash the electrode and Temperature compensation rod with distilled water andwipe it with tissue paper.
Put the electrode and automatic temperature compensation rod into the sampleand keep it until stable reading appears in the displays; note the reading.
Discard the sample and wash the electrode and automatic temperaturecompensation rod with distilled water and wipe it with tissue paper.
Keep the electrode back in the container.
Precaution: Do calibration with appropriate buffers before taking readings.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
51/202
47
pH Value Test (Simlified Procedure):
To measure pH value of the effluent of bio toilets to ensure environmentalsafety.
S.No.
Description Details
01 Purpose of test To measure pH value of the effluent of biotoilets to ensure environmental safety.
02 Target value 6 9 pH
03 Equipments required Portable pH meter
04 Other equipments pH indicator paper of all ranges
05 Consumables pH calibration buffers (4.0, 7.0, 10.0)06 Quantity of sample 50-100 ml
07 Electricity requirement Yes
08 Frequency of sampling 90 days
09 Testing spot Railway laboratory
10 Staff required 01
Procedure:
First of all, take 02 ltrs. Effluent sample in the bottle from bio-toilet tank.
Take 50 100 ml of mixed effluent sample in a beaker.
Put pH meter on the stand .
Mix the liquid properly.
Put the electrode of portable pH meter in the beaker until stable reading appearsin the displays;
Note the reading from display of Ph meter. Discard the sample and wash the electrode of pH meter with distilled water and
wipe it with tissue paper.
Keep the electrode back in the container.
Precaution: Do calibration with appropriate buffers before taking readings.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
52/202
48
2. Total Solids (TS) Test:
This test should be carried out to estimate amount of total solids available in theeffluent.
S. N Description Details
1. Purpose of test To estimate amount of total solids in the effluent.2. Set Target
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
53/202
'
3. Total Dissolved Solids (TDS):
This test should be carried out to estimate amount of total dissolved solids availablein the effluent.
S. N Description Details
1. Purpose of test To estimate amount of total dissolved solids in
the effluent.
2. Target value < 350 mg /100 ml
3. Equipments required Electronic weighing balance, pipettes, Silica
crucibles, Hot air oven, desiccators, filter
assembly, vacuum pump
4. Consumable Self indicating silica gel. Whatman Glass wool
filters
5. Quantity of sample 25 ml
6. Electricity requirement Yes
7. Frequency of sampling 90 days
8. Testing spot Railway laboratory
9. Staff required 1
Procedure:
1. Heat an empty and clean silica crucible at 180 2C for 1 to /2 hour in a hot air
oven, cool it in desiccator to room temperature and weight.
2. Insert disc and filter assembly, apply vacuum and wash disc with three
successive 20-mL volumes of reagent grade water.
3. Dry it in a hot air oven at 180 2C for 1 hour in an oven. Store in desiccators
until needed. Weigh immediately before use.4. Stir sample with a magnetic stirrer and pipette a measured volume (25 ml) into a
glass fiber filter with applied vacuum.
5. Wash with three successive 10-mL volume of distilled water, allowing complete
drainage between washings.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
54/202
1
6. Transfer total filtrate (with washings) to a pre-weighed clean silica crucible.
7. Dry it in a hot air oven at 180 2C for 1 hour in an oven. Cool it in desiccators
to room temperature. Note the final weight
Calculations:
mg total dissolved solids/ 100 mL = (A B) X 100 X1000 / Volume of sample (mL)
Where,A Weight of the dried residue + dish (g)
B - Weight of dish (g)
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
55/202
2
Total Dissolved Solids (TDS) (Simplified Procedure):
This test should be carried out to estimate amount of total dissolved solids availablein the effluent.
S.
No.
Description Details
01 Purpose of test To estimate amount of total dissolved solids in
the effluent.
02 Target value < 350 mg /100 ml
03 Equipments required Portable TDS meter
04 Other equipments Beaker 100-150 ml
05 Quantity of sample 100 ml
06 Frequency of sampling 90 days
07 Testing spot Railway laboratory
08 Staff required 01
Procedure:
1. Ensure availability of all the equipments and effluent in the lab
2. Fill the sample effluent in the beaker and mix it properly.
3. Keep the TDS meter ON and put electride in the beaker up to marking
line.
4. TDS value will appear on the display of TDS meter. It should be noted.
5. Repeat the test again and record the TDS value in the register.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
56/202
3
4. Total Volatile Solids (TVS):
This test should be carried out to estimate amount of total volatile solids available
in the effluent.
S.
No.
Description Details
1. Purpose of test To estimate amount of total volatile solids available in
the effluent.
2. Target value < 500 mg /100 ml
3. Equipments required Electronic weighing balance, pipettes, Silica
crucibles, Hot air oven, muffle furnace, desiccators,
filter assembly.
4. Consumable Self indicating silica gel. Whatman Glass wool filters
5. Quantity of sample 25 ml
6. Electricity requirement Yes
7. Frequency of sampling 90 days
8. Testing spot Railway laboratory
9. Staff required 1
Procedure:
1. Heat an empty and clean silica crucible at 550C for 1/2 hour in muffle furnace.
2. Cool it in dissicator to room temperature and take the initial weight.
3. Pipette a measured volume of well mixed sample (25 ml) to a pre-weighed silica
crucible.
4. Keep the silica crucible in a hot air oven at 103 105C; keep till the water gets
dried.
5. Remove the silica crucible and keep it in muffle furnace at 550C for 1 hour.
6. Keep the silica crucibles in desiccators.
7. Note the final weight
Calculations:mg total volatile solids/ 100 mL = (A B) X 100 / Volume of sample
(mL)
Where,
A Total solids (mg)
B - Weight of the dried residue + dish (g) - Weight of dish (g) then
convert the value to milli gram
Note: The total solids amount is calculated as described above.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
57/202
4
5. Chemical Oxygen Demand (COD) Test:
This test should be carried out to estimate COD of the effluent to ensureenvironmental parameters.
S.No.
Description Details
1. Purpose of test To estimate COD of the effluent to ensure
environmental parameters.
2. Target value < 2000 mg O2/ Litre
3. Equipments COD digester along with digestion tubes and
condensers, Burettes, magnetic stirrer, magnetic
bars.
4. Consumable required Sulphuric Acid, Silver sulphate, mercuric chloride,
potassium dichromate, ferroin indicator, ferrous
ammonium sulphate.
5. Quantity of sample 5-10 ml of sample
6. Electricity
requirement
Yes
7. Frequency of
sampling
90 days
8. Testing spot Govt. approved Labs./DRDE
9. Staff required 01
Regents:
A. Standard potassium dichromate solutions (0.04167M) Dissolve 12.259 g
K2Cr2O7, previously dried at 150C for 2 hours, in distilled water and dilute to
1000 mL.
B. Sulfuric acid reagent: Add Ag2SO4 crystals or power to concentrate H2SO4 at
the rate of 5.5 g Ag2SO4/ Kg of H2SO4. Let it stand 1 or 2 days to dissolve.
C. Ferroin indicator solution : Dissolve 1.485 g of 1, 10 phenanthroline
monohydrate and 695 mg FeSO4 .7 H2O in distilled water dilute to 1000 mL.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
58/202
D. Standard Ferrous ammonium Sulphate titrant ( 0.25) Dissolve 98 g of
Fe(NH4)2 .6 H2O in distilled water. Add 20 mL con. H2SO4 , cool and dilute to 1
litre standardize this solution on the day of estimation against Standard
potassium dichromate solution.
E. Mercuric sulphate - HgSO4 crystals or powder.
F. Sulfamic acid interference of nitrates is to be eliminated.
G. Potassium Hydrogen Phthalate:lightly crush and then dry KHP to constant
weight at 110C. Dissolve 425 mg in distilled water dilute to 1000 mL. KHP
has a theoretical COD of 1.176 mg O2/ mg and this solution has a theoretical
COD of 500g O2 / mL.
Procedure:
Take 5 ml of sample and dilute it to 50 ml. (Note: In case higher COD samples
dilute 100 times).
Add 100 mg HgSO4, several glassbeads/ Chemstones, and very slowly add
5.0 ml of sulfuric acid, with mixing to dissolve HgSO4.
Cool while mixing to avoid possible loss of volatile materials.
Add 25.0 mL 0.04167 M K2Cr2O7solution and mix. Attach condenser to digestion tubes and cool the contents by swirling and
mixing in running tap water.
Add sulfuric acid reagent (20 mL) through open end of condenser.
Continue swirling and mixing while adding sulfuric acid reagent.
Cover open end of condenser with a small beaker / aluminum foil to prevent
foreign material from entering refluxing mixture and to avoid possible loss of
volatile materials. Do reflux / digestion for 2 hours @ 150C.
Cool and wash down condenser with distilled water.
Disconnect reflux condenser and dilute mixture to about twice its volume with
distilled water. Cool to room temperature.
Titrate excess K2Cr2O7with FAS, using 0.10 0.15 mL (2 3 drops) ferroin
indicator.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
59/202
#
Observe sharp colour change from blue green to reddish brown that persists
for 1 min or longer.
Duplicate determinations should agree within 5% of their average.
In the same manner reflux and titrate a blank containing the regents and a
volume of distilled water equal to that of sample.
Determination of a STD solution:
Evaluate the technique and quality of the reagents by conducting the test on a
standard KHP solution.
Calculations:
COD (mg/ ml) = (A-B) X N X 8000 X Dilution Factor / mL of sample
Where,
A mL of FAS used for blank
B mL of FAS used for sample
N Molarity of FAS (0.25)
8000 Mill equivalent weight of Oxygen.
Precautions:
1. Mix reflex mixture thoroughly before applying heat to prevent local heating offlask bottom and a possible blowout of flask contents.
2. Make dilution according to the COD range of the samples.
3. Ensure complete dissolution of silver sulphate in sulphuric acid reagent.
4. Store sulphuric acid reagent in a amber colored bottle in dark or wrap it with
aluminum foil.
5. Wear lab coat and hand gloves during handling of acids.
6. Always add acid along the wall of the container to the water.
7. Do titration once the content reaches room temperature.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
60/202
)
6. Fecal Coli Forms count:
This test should be carried out to estimate the fecal coli form bacteria count onbio toilet effluent.
S. N Description Details
1. Purpose of test To estimate the fecal coli form bacteria count on
effluent.
2. Target value > 99% reduction ( Lessthan 108/100 ML )
3. Equipments Laminar Air Flow Chamber, Incubator
4. Consumables Test tubes, FC media plates, spreaders,
pipettes, conical flasks, Glass marker, magnetic
stirrer.
5. Quantity of sample 10 ml
6. Electricity requirement Yes
7. Frequency of sampling 90 days
8. Testing spot Only in Govt. Labs.
9. Staff required 01
Procedure:
Media & Plate Preparation:
A. Media Composition:
S. No. Constituents Amount (g/ L)
1. Lactose 12.5
2. Tryptone 1
3. Protease Peptone 5
4. Sodium chloride 5
5. Yeast extract 3
6. Bile salts 1.5
7. Aniline blue 0.1
8. Distilled water 1000 ml
1. Boil the media for 30 minutes, do not sterilize the media.
2. Add approximately 25 ml of cooled FC medium to each Petri dish. Upon
solidification of the media close the aids and keep it for further use.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
61/202
7
B. Dilution preparation:
1. Label 90 ml water blank conical flask as No.1(10-1) and subsequent 9 ml water
blank test tubes as No. 2(10-2), No. 3(10-3), No. 4(10-4), No. 5(10-5), No. 6(10-
6), No. 7(10-7), No. 8(10-8), with a glass marker.
2. Take 10 ml of well mixed effluent sample and add to 90 ml water blank to make
(10-1) dilution. (Note: Use sterile pipettes for transfer and carry out dilution in
laminar air flow chamber)
3. Vigorously shake the dilution in a magnetic stirrer for 2 minutes to obtain uniform
suspension.
4. Transfer 1 ml of suspension from No.1 into No.2 tube to make (10-2
) dilution andshake it vigorously for 1 min.
5. Make further dilutions as prepared above.
Note: Do estimation of fecal coli form count in human excreta for comparison and
calculation.
C. Inoculation:
1. Place the spreader into a beaker containing 95% ethyl alcohol. Remove thespreader and pass it through burner flame. Burn off the alcohol completely and
cool the rod for 30 to 45 seconds.
2. Transfer 0.1 ml (100l) of suspension each from different dilution into 3 plates.
Place it in the center of the plate.
3. Remove the Petri dish cover, with one hand touch the spreader gently on the
surface of the agar and move it back and forth while rotating the plate with the
other hand.
4. When the suspension gets dried or absorbed on the agar medium, replace the
cover.
5. Incubate the plates in an uprght position in an incubator at 44.5C for 48 hours.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
62/202
8
Observations:
1. Observe the plates for number and distribution of Blue/ Bluish tinged colonies.
Do not consider white or creamy or dull white colonies.
2. Select the plate from the appropriate dilution which contains colonies in therange of 30 to 300 and make the plate counts.
3. Determine the average of the triplicate colony count.
4. Record your results.
Calculation:
Calculate fecal form count in terms of number of CFU / 100 ml by applying the
following formulas.
Fecal coli form count (CFU / 100 ml)= Mean plate count X Dilution factor X 100Volume of sample
% reduction = (count in human excreta count in sample) X 100count in human excreta
Example
If 160 colonies were counted (average of 3 replicate) in 10-3dilution the fecal coli
form count would be:
FC count (CFU / 100 ml) = 160 X 1000 X 1000.1
= 1.6 X 108
Precautions:
1. The sample should be mixed homogenously.
2. Each dilution must be thoroughly shaken before removing an aliquot for
subsequent dilution.
3. Use separate sterile pipettes or tips for each dilution.
4. All dilution making and inoculation should be done in laminar air flow chamber.
5. The plates should be incubated in a upright position.
6. 25-30 ml media should be added to avoid cracking of medium during incubation.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
63/202
#'
(B) Testing Scheme for Bacteria Culture(Microbial Inoculum).
Following parameters have been recommended for testing of Microbial Inoculumproduced in Inoculum generation Plant .
1. pH Value Test:
This test should be carried out to measure pH value of the inoculum.
S.
No.
Description Details
1. Purpose of test To measure pH value of the inoculum.
2. Target value 6.5 7.5. pH
3. Equipments required Table top pH meter / pH indicator strips,
magnetic stirrer.
4. Consumables pH calibration buffer (4.0, 7.0, 10.0), magnetic
stirrer bars.
5. Quantity of sample 50 100 ml.
6. Electricity requirement yes
7. Frequency of sampling Once in a week.
8. Testing spot Railway laboratory
9. Staff required 01
Procedure:
Take 50 100 ml of well mixed inoculum in a beaker.
Put a magnetic bar and keep the beaker on a magnetic stirrer and mix it
continuously.
Wash the electrode and Temperature compensation rod with distilled water
and wipe it with tissue paper.
Put the electrode and automatic temperature compensation rod into the
sample and keep it until stable reading appears in the display; note the
reading.
Discard the sample and wash the electrode and automatic temperature
compensation rod with distilled water and wipe it with tissue paper.
Keep the electrode back in the container and put them in stand.
Precaution: Do calibration with appropriate buffers before taking readings.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
64/202
#1
2. Bio-gas Test:
This test should be carried out to measure amount of Biogas produced duringfermentation in the Inoculum generation plant.
S.
No.
Description Details
1. Purpose of test To measure amount of biogas produced during
fermentation.
2. Target value -
3. Equipments Gas flow meter / water displacement assembly.
4. Consumables Glass wares, cork, Glass L bends
5. Quantity of sample Not applicable
6. Electricity requirement No.
7. Frequency of sampling Daily
8. Testing spot At Plant/Site
9. Staff required 01
Procedure:
Take 2000 ml of well mixed inoculum in a 3 L beaker.
Set the water displacement assembly.
Incubate the set-up in BOD incubator @ 30 0C for 24 hours.
Measure the volume of water displaced.
The amount of water displaced is equal to amount of gas produced.
Precaution:Make sure water column in the exit tube of the water beaker.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
65/202
#2
3. Percentage Methane Test:
This test should be carried out to measure the methane content of biogas producedduring fermentation in the Inoculum generation plant.
S. N Description Details
1. Purpose of test To measure the methane content of biogasproduced during fermentation.
2. Target value 40 70 %
3. Equipments required Gas chromatograph / online gas analyzer.
4. Consumables Serum bottles, Aluminum crimp, Butyl rubber
septum, Gas tight syringe (50 250 l), Nitrogen
cylinder, Zero air/O2cylinder, Hydrogen cylinder,
standard methane gas.
5. Quantity of sample Not applicable
6. Electricity requirement Yes.
7. Frequency of sampling weekly
8. Testing spot Railway laboratory
9. Staff required 01
Procedure:
Take 2000 ml of well mixed inoculum in a 3 L beaker. Set the water displacement assembly.
Incubate the set-up in BOD incubator @ 30 0C for 24 hours.
Fill a 30 ml serum vial with water, put a butyl rubber septum, aluminum crimp
and crimp it all the side.
Inject the biogas formed in the water displacement assembly into the serum vial
through a silicone tube fitted with needle.
Allow the exit of water through another needle inserted in the butyl rubber
septum.
Collect at least 15 ml of biogas.
Store it in a inverted position untill analysis.
Note: Make sure, gas bubble should not be there in the serum bottle before
biogas collection.
Inject 100 l standard methane gas and record the elution time of the gas.
(Note: Elution time is the time elapsed between injection of sample and response of the peak at top).
Inject 100 l of the biogas sample. Record the % methane in biogas.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
66/202
#3
4. MPN Count for Methanogens:
This test should be carried out to estimate the methane producing bacteria count ininoculum.
S.No.
Description Details
1. Purpose of test To estimate the methane producing bacteria count ininoculum.
2. Target value >1000 / ml
3. Equipments required Gas chromatograph, Gassing manifold, hotplatestirrer, laminar air flow chamber, incubator,micropipettes, hand operated crimper, hand operatedDecapper.
4. Consumables Serum bottles, Aluminum crimp, Butyl rubber septum,Gas tight syringe (50 250 l), Nitrogen cylinder, CO2
cylinder, Hydrogen cylinder, sterile Disposablesyringes, Resazurin and chemicals listed below in thetable.
5. Quantity of sample ~ 50 ml
6. Electricity requirement Yes.
7. Frequency of sampling Monthly
8. Testing spot In Govt. approved Laboratory Only
9. Staff required 02
Procedure:
Growth medium preparation:
SlNo
Constituents Amount (g / L)
1 KH2PO4 0.32 K2HPO4 0.33 (NH4)2SO4 0.34 NaCl 0.65 MgSO4.7H2O 0.136 CaCl2.2H2O 0.008
7 FeSO4 0.0028 Yeast extract 2.09 Trypticase 2.010 Trace element solution 1.0 ml
11 Trace vitamin solution 1.0 ml12 Sodium acetate 2.513 Sodium formate 2.514 Resazurin 1.0 ml
15 Reducing agent 12.5 ml
16 pH 6.817 Gas phase (N2:H2) 80:20
Trace Element Solution:
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
67/202
#4
SN Constituents Amount (g / 100 ml)
1 Nitrilo triacetic acid 1.52 MgSO4.7H2O 3.03 MnSO4.2H2O 0.54 NaCl 1.05 CoCl2 0.1
6 FeSO4.7H2O 0.17 CaCl2.2H2O 0.18 ZnSO4 0.19 CuSO4.5H2O 0.0110 AlK(SO4)2 0.0111 H3BO3 0.0112 Na2MoO4.2H2O 0.1Note:Dissolve nitrilotriacetic acid with KOH to pH 6.5 and thenadd other salts.
Trace Vitamin Solution:
Reducing Agent:
SlNo
Constituents Amount (g / 100 ml)
1 Cysteine hydrochloride 2.02 Sodium sulphide 2.0Adjust pH of Cysteine hydrochloride to 9.0
Indicator Solution:
Sl No Constituents Amount (g / 100 ml)1 Resazurin 0.10
1. All the ingredients of the medium were added in the required amount except theheat labile components and half the volume (6.25 ml) of reducing agent.
2. Heat the medium on a hot plate or heating mantle at 70 0C and sparge themedium continuously with O2free N2till the medium becomes colorless.
3. Take 60 ml serum vials and replace the air with nitrogen for 2 min.
4. Dispense media (22.5 ml) in individual vials and seal it with butyl rubber andaluminum crimps and seal it tightly.
5. Do autoclaving for 15 min at 121 0C for 20 min.
SlNo
Constituents Amount (mg / 100 ml)
1 Biotin 2.02 Folic acid 2.03 Vitamin B12 0.14 Pyridoxine HCl 10.05 Thiamine 5.06 Riboflavin 5.07 Nicotinic acid 5.08 D,L- Calcium pantothenate 5.0
9 p- aminobenzoic acid 5.010 Lipoic acid 5.0
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
68/202
#
6. Let the medium to cool to room temperature and add rest of the amount ofreducing agent (6.25 ml) with syringe and heat the butyl rubber seal for 10 secwith a sprit lamp.
Note: The medium should be colourless.
Dilution Preparation:1. Label 22.5 ml anaerobic diluent medium containing serum vials as No.1(10-1)
No. 2(10-2), No. 3(10-3), No. 4(10-4), No. 5(10-5), No. 6(10-6), No. 7(10-7), No.8(10-8)with a glass marker.
2. Take 2.5 ml of well mixed effluent sample and add to 22.5 ml water blank tomake 10-1 dilution. Vigorously shake the dilution for 15 seconds to obtainuniform suspension.
3. Transfer 2.5 ml of suspension from No. 1 into No. 2 tube to make 10-2dilutionwith a sterile syringe and shake it vigorously for 15 seconds.
4. Make further dilutions as prepared above.Inoculation:
For each dilution prepare 5 replicate serum bottles for inoculation. Total 45medium bottles are needed.
Transfer 2.5 ml of suspension each from different dilutions into set of 5 serumvials with medium by sterile syringe and heat the butyl rubber septumimmediately.
Incubate the serum vials in an upright position along with uninoculated controlin an incubator at 30 0C for 20 days.
Observations:
Analyze the gas from the head phase for presence of methane as describedabove with gas chromatograph.
Note the number of positive and negative vials for each dilution.
Methanogenic MPN is computed on the basis of bottles showing positive test.Dilution factor is taken into consideration while calculating the MPN.
Record your results
Calculation:
1. To calculate MPN of methanogens in the original sample
Select as P1: the number of positive tubes in the least concentrated dilution inwhich the greatest number of tubes is positive; and p2 and p3 represent thenumbers of positive tubes in the next two higher dilutions.
Use table of MPN for use with 5 tubes per dilution, then find the row ofnumbers in MPN table in which p1 and p2 correspond to the values observedexperimentally. Follow that row of numbers across the table to the columnheaded by the observed value of p3. The figure at the point of intersection isthe most probable number of organisms in the quantity of the original sample
represented in the inoculum addedin the second dilution (p2). Multiply this figure by the appropriate dilution factorto obtain the MPN for the original sample.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
69/202
##
Example
Suppose the following observations were made:
Dilution No. of positiveNeat 5
10-1 510-2 510-3 510-4 310-5 110-6 0
In this series, p1 = 5, p2 = 3, p3 = 1. For this combination of p1, p2 and p3, the MPN
table gives 1.1 as the most probable number of organisms in the quantity of the
inoculum applied in the10-4
(p2) dilution. Multiplying this number with dilution factor104gives 1.1 X 104 as the MPN for the original sample (2.5 ml). Convert the value to
1 ml by dividing with 2.5 i.e. 1.1 X 104/2.5 = 4.4 X 103
Precautions:
1. The sample should be mixed homogenously
2. Each dilution must be thoroughly shaken before removing an aliquot for
subsequent dilution
3. Use separate sterile pipettes or tips for each dilution
4. Use sterile pipettes for transfer,
5. Carry out dilution as quick as possible and immediately seal the butyl rubber
septum and aluminum crimps. Alternatively the dilution can be done in
anaerobic glove box.
6. The Heat labile compounds should be added after autoclaving.
7. Trace element solution and reducing agent solution should be prepared
separately and should be autoclaved.
8. Trace vitamin solution should be sterilized by filtration.
9. At least three consecutive dilutions should be inoculated.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
70/202
#)
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
71/202
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
72/202
#8
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
73/202
)'
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
74/202
)1
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
75/202
)2
Minutes of the Meeting held at DRDE on 22.12.2011
A meeting was held at DRDE on 22.12.2011 in connection with finalization of detailedschedule of work for floating tender by MIB workshop NGP & following observationshave been recorded.
Meeting attended:
1. CME/PL/SECR2. Director (Mech)/CAMTECH3. JE/RCF4. SSE/ICF
Civil Work:
Inoculum Generation Facility -
S.No. Work Proposed1. Excavation:Total Excavation in earth for foundation of Sump well i.e. dressing of sides
in all types of soil, rectangular storage tank, gas collection chamber, including disposalof earth-
= 264.66 Cum
2. Foundation: Providing and laying plain cement Concrete mechanically mixed, vibrated,M-15 grade with 20 mm, graded metal (Hard Metal B.T.) for foundation course up tocomplete work.= 12.50 Cum
3.
i.
ii.
iii.
iv.
v.
Proving and laying M-20 reinforced Cement Concrete Mechanically mixed vibrated with20 mm, hard graded metal (B.T. Metal) excluding cost of reinforcement but i/c form workpropping bracing etc. completeBottom Slab = 3.43 Cum
Cylindrical Wall = 13.85 Cum
Haunching = 0.18 Cum
Top ring Beam = 0.75 Cum
Top Dome = 2.45Cum
Total= 20.66 Cum.
4. Reinforcement for concrete work @ 2% of volume i.e. 37.15Cum => 0.75M3 x 7850kg/Cum.= 5,832.55 kg. i/c cutting bending, centering, overlaps, wastage etc. complete.
5. Provision of providing & fixing 4 pipes approx.120 feet for inlet, outlet, scour, overflowincluding labour and material nut, bolts, valves, bends, transportation, testing etc. asshown in the drawing
6. Provision for 20 feet long Aluminum ladder, ventilation shaft, manhole covers, watergauge, water proofing treatment, back filling, site grading, plinth protection andmiscellaneous work.
7. FRP Lining inside the walls of tank for area approx.50 m2 and approx. 70 m2 P/Uinsulation from outside the walls.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
76/202
)3
S.No. Work Proposed
8. Water Chiller: Water cooled chiller of 20 ton capacity consisting of 10 ton capacityDanfoss scroll hybrid compressors each with FRP cooling tower of 30 TR capacityand 5 HP electrical motor with mono block pump with all f itting arrangements.
9. Rectangular Storage Tank: Overflow chamber (Rectangular Storage Tank) of 32M3 Capacity of Brick wall construction covered with 5 mm thick M.S. Sheetfabricated cover with handle along with the provision of one end hinges.
10. Gas collection chamber: 1480 mm inner dia S.S./FRP floating dome (sheetthickness size 1.5mm) volume approx. 500 ltrs capacity, round chamber for methanegas collection with the provision of holding cantilever height approx.12 feet alongwith steel wire rope of suitable capacity & iron counter weight with container.
11. Mud Pump:Provision of one Mud pump of 5HP capacity for agitation of slurry with 5HP elect. motor with starter & other accessory.
12. Standby Mud Pump:Provision of one Mud pump of 5HP capacity for agitation ofslurry with 5 HP elect. motor with starter & other accessory.
13. Gas cooling coil: (19 mm ) Tin coated copper cooling coil fitted approx. 1000feet inside the inoculums plant as per chiller capacity.
14. Covered shed: 12000 mm long X 9000 mm width X 3600 mm height M.S. Shedwith RCC foundation with 6 MS channels and jally & provision of Antilock tileflooring at plant area .
15. Operators Cabin:Construction of RCC roof operators cabin size 3000 x 3000 mm(
U/R pile foundation) with the provision of 02 nos. windows & one door & flooring
16. Store & Bio Toilet: Construction of RCC roof store size 3000 x 3000 mm withattached toilet ( U/R pile foundation) size 2000 x 1800 mm with the provision of 02nos. windows & one door & flooring
17 Surrounding wall and chain link fencing: Construction of 2 feet high brick walland fitting of chain link fencing supported on iron angles height approx. 1.82 metersabove the wall size 55 X 45 feet & fabrication of 12X6 feet size MS gate or brickwall as shown in estimate.
******
Copy to/: CME/PL/SECR, JE/RCF , SSE/ICF for information.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
77/202
)4
Electrical Work:
SN Work proposed Load/quantity
Estimatedcost
( in lacks)
1. Installation and electrical connections to water cooledchiller plant of 20 Ton capacity (with 02 compressors of10Ton capacity each)
15 kW --
2. Installation and electrical connections to cooling towerwith 3 HP Motor & lifting Pump
2 kW --
3. Installation and electrical connections to agitation mudpump with 3 HP low rpm Motor
2 kW --
4. Installation and electrical connections to 02 nos. MudPump with 1.5 HP Motor
2 kW --
5. Installation and electrical connections to 02 nos. MudPumps with 5 HP Motor
3.5 kW --
6. 100 Amp Main distribution Board with TPIC switch andControl Panel consists of 3-phase supply bus bar for mudpumps, water pump, chiller and circulating pump etc.,single phasing preventer, earth fault preventer,distribution MCBs, phase indicators etc..
1.50
7. 05 No. Industrial out door type 2 x 36 Watt T5 FTL polemounted fittings.
0.5 kW 0.50
8. 03 Core 4 Wire 35 mm2 Armoured main service cable Railway supply to plant MDB with standby cable.
50 meters 0.75
9. 03 Core 4 Wire 10 mm2 cable from MDB to chiller and 5/3HP pump motors.
50 Meters 0.30
10. 03 Core 4 Wire 06 mm2
cable from MDB to 1.5 HP pumpmotors, room lights and area lights.
50 Meters 0.20
11. Maintenance free earthing arrangement 02 earthingSet
0.25
12. Light & Fan wiring with accessories in operator room,store room and toilet02 Fan, 04 F/T, 04 Sockets -05Amp, 02 Power Sockets -15 Amp
--- 0.10
13. Fire Extinguishers (DCP Type) 04 Nos. 0.10Total Load 28.5 kW 03.70
Total Estimated Cost of work (Approximately) 3.70 Lacks
***
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
78/202
)
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
79/202
)#
Effluent parameter Analysis, instruments
Specifications and approximate cost
S.No Instrument Specifications ApproximateCost (Rs)
1. Table top pHmeter
Ph accuracy 0.01 units,Calibration up to 3 points with auto bufferrecognition,Display large dual line,Temperature compensationAutomatic/manual 0 - 100C,Memory 50 data sets,Power requirements 220 VWarranty 1 Year for instrument and 6 months forelectrode.
25,000
2. Portable pHmeter
Ph accuracy 0.01 units,Calibration up to 2 points with auto bufferrecognition,Temperature compensationAutomatic/manual 0 - 100C,Power requirementsBattery operated, Auto poweroff for 10 minutes.Warranty 1 Year for instrument and 6 months forelectrode.
5000
Table to H meter Portable H meter
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
80/202
))
3. Hot air oven Temperature Up to 250C,Temp control Thermostatic 2C,Oven Double walled Aluminum/SS, outside MSwith epoxy coating.ShelvesWire mesh shelves.
Door With synthetic rubber gasket.Air circulation Fan present.Size 455 mm x 455 mm x 455 mm (W x D x H)
40,000
HOT AIR OVEN Filter flask
assembly
4. Filtering flaskassembly
Assembly SS/ Glass.Filter Dia- 47 mm.Filtration area :5 -10 cm2.Size 15-20 cm X 5-10 cmOut let No. 8 perforated silicone
Volume -500 mlStopper mounted on 1 L Glass vessel
10,000
Silica crucibleWeigi!g bala!ce
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
81/202
)7
5. Muffle Furnace Size 125 mm x 125 mm x 300 mm (W x D x H)
Power 3.0 KW
Temperature Up to 900C,
Outer Casting MS with epoxy coating.Temp Control Digital Temperature controller cum
indicator.
Heating element- Kanthal wire/ special high
temperature alloy
25,000
"#FF$E F#RNA%E
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
82/202
)8
6 COD Digester Controller Microprocessor Based Digital TemperatureIndicator cum ControllerDisplay LED with set value (SV) and process value(PV)Block Dimensions (WxDxH) in mm-
270 mm(L) x 150 mm(W) x 70 mm(D)Heater Load 1.0 KWTube cavity 40 mm()x 65 mm (D)No. of cavities 15 holes to accommodate 15 samplesGlass Tube Size Supplied with 15 Nos of glass tubesof size 38 mm ()x 200 mm (Length)Glass Air Condenser Size 15 nos. of air condensersof 600 mm length each.Temperature RangeAmbient+5C to150 CTemperature Accuracy +1 CSensor RTD (Pt- 100)Material External Power Coated CRC SteelBlock Polished AluminumTube Rack -1 No.Power Supply 230 V AC, 50/60 Hz.Optional spare digestion tubes (15 No.)Tube rack (1 No.)
42,000
6a. Lab Coat and Hand Gloves
%O& &I'ESTION APPARAT#S
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
83/202
7'
7. Magnetic Mixingplatform
Maximum Stirring Capacity 1 liter (0.26 gallons)
Speed Range Min. 100 rpm, Max. 1000 rpm
Cover Material ABS plastic
Dimensions 137 mm (dia) x 51 mm (h)Weight 640 g (1.4lb)
Accessories:Micro Stir Bars for Magnetic Stirrers.
25,000
5H Eui54en"s
8. Autoclave Material of vessel inside Stainless steel, outside epoxy coated MSEffective volume 22 L (250 mm x 450 mm; Dia xdepth)Weight -15 - 25 Kg.Power consumption 2 - 3 KW.Operating temperature Range 120 10CKeep warm temperature 45 C 60 C.Safety device Safety valve, over temperature &over pressure limiter, Error indicators.Accessories 2/3 stainless steel baskets, indfoss
piezostat to adjust pressure between 15 to 22 PSI
20,000
pH i!(icator strips"ag!etic bars"ag!etic stirrer
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
84/202
71
9. Laminar air flowchamber
Size 1200 mm x 600 mm x 600 mm (L x W x D)
Door Acrylic
Light Both UV and Flourescent
Outer casting Duro board / SS 304.Filter HEPA with 0.3 m pore size.
Accessories:Cock for Gas/vacuum line, Bunsen
burner
1,50,000
$ami!ar air flo) camber
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
85/202
72
10. Incubator Temperature Ambient to 60 C.
Temp Control Thermostatic 1C
Size 450 mm x 450 mm x 600 mm (LxWxD)
Heating elements:Bottom.Casing inside Double walled
Aluminium/SS, outside MS with epoxy coating
Door Glass window and with synthetic rubber
gasket.
Shelves Wire mesh shelves,
Power 240 V AC
Air circulation Fan Present.
40,000
I!cubator
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
86/202
73
11 Burette Class A class.Make PTFE pathway.Capacity 50 ml.Graduation interval 0.1 ml.Height 720 mm.
Tolerance 0.1 ml.Accessories:leak proof stopcocks.
2500
12 Fume HoodSystem
Internal size:L 1200 x D 600 x H 600 mmMake:woodWorking Space: Stainless steel 316, Acid resistant.Wash basin size:250 x 200 x 150 mm depth ofStainless Steel 316.Sliding slash:Glass make moves vertically up anddown with concealed counter balanced weight.Exhaust system:Exhaust fan with stainless steeldeck & Duct to take out fumes.Electrical:1 fluorescent lamp, power socket (5/15A).Accessories:Cock for Gas supply
50,000
13 Micropipettes Digital micropipetteChemical resistantAutoclavableVolume Range
20l - 200 l100l - 1000 l1 ml - 5 ml
50,000
Graduated glassware 10,000Sampling containers of plastic / Glass make 5,000Refrigerator 15,000Thermometer 1,000Volumetric glassware 10,000Magnetic bars all range 5,000Tissue paper -Blotting paper -Para film -Cotton -
14 GeneralFacilitiesRequired
Test tube bucket -
"icro i ette
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
87/202
74
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
88/202
7
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
89/202
7#
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
90/202
7)
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
91/202
77
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
92/202
78
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
93/202
8'
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
94/202
81
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
95/202
82
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
96/202
83
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
97/202
84
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
98/202
8
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
99/202
8#
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
100/202
8)
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
101/202
87
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
102/202
88
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
103/202
1''
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
104/202
1'1
INDIAN RAILWAYS
TRIAL/TEST SCHEMEFOR
FIELD TRIAL OF BIO TOILETS
(DRDE TECHNOLOGY)ONINDIAN RAILWAY PASSENGER COACHES
S.No.
Amend./Rev. No.
Date/Monthof Issue
Page No. Reason for Amend./ Rev.
1 Rev.Nil Dec., 2010 NA Ist Issue
2 Rev. 1 Jan., 2011 3 Frequency of testing of effluentdischarge changed & agency specified.
3. Rev.2 May, 2011 All pages i) Reasons of chocking/
malfunctioning of toilet with coach&lav. variant added in visualobservations.
ii) Annexure-I Generalised.4. Rev.3 June, 2012 All Pages i) Review of testing parameters &
inclusion of parameters VolatileSolids & Faecal Coliforms.
ii) Inclusion of:- Sampling Criteria- Testing procedure
5 Rev-4 October,
2012
All pages - Complete trial scheme revised.
- Sampling procedure and list of testlabs added as annexure III and IV.
ISSUED BY:
CARRIAGE DIRECTORATERESEARCH, DESIGNS AND STANDARDS ORGANISATION
(MINISTRY OF RAILWAYS)MANAK NAGAR LUCKNOW-226 011
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
105/202
1'2
1. TRIAL/TEST SCHEME FOR IR-DRDO BIO TOILETS IN INDIAN RAILWAY
Indian Railway has developed IR-DRDO bio-toilets jointly with the DRDO. Toestablish it in IR conditions trials on IR is going on. For proper monitoring ofthese bio-toilets, a test/trial scheme has been prepared. This Test /Trialscheme may be divided mainly in two parts.
A) Visual inspection.B) Quality check of the effluent discharged from bio toilet.
Period for monitoring of above Test /Trial scheme shall be 2 POH Period i.e.36 months. Consolidated test / trial report shall be submitted to RDSO on 6monthly basis.
To cater the requirement of doing these tests efficiently, it has also beenproposed to provide suitable training to Railway staff by CAMTECH in liaisonwith DRDE so that proper monitoring can be ensured at appropriate level inthe Zonal Railways. Some of the minor tests of effluent of bio-toilets havebeen proposed to be carried out by coaching depot staff at In-House Labsbeing setup at diesel sheds/ coaching depots for this purpose.
The sampling procedure and testing procedure of effluent discharge of IR-DRDO bio toilets has been tentatively finalized by DRDE based on the pastexperience of 12 months trial is attached as Annexure - IIIand Annexure - V.
2. VISUAL INSPECTION DURING FIELD TRIAL
The following parameters will be monitored during field trial by concern Railwayin each trip.
Date of Inspection Coach No. Type of coach .. Toilet Variant...
S.No.
Parameters to be checked Observations/Remarks
1. Thorough inspection of mounting/securingarrangement for the bio-digester tank.
2. Any leakage in joints/connections in thecomplete system including retention tank, air& water pipelines
3. Adequacy of the provisions made forsegregation of non-bio-degradable items.
4. Functionality of all controls & indications i.e.Flush button/leverWater tapsPneumatics operation efficiency (if any)
5. Adequacy of flushing of the pana) By using pressurized flushingb) By Normal manual flushing
6. Any mal odour/stench Yes/No
(Specify if yes, Light, Medium or Heavy)
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
106/202
1'3
7. Overall Cleanliness level of the toilet room
8.Notices for users and maintenance personnelin Hindi, English & Regional Language of theoriginating & destination station.
9.Emergency operation of flush arrangement
without power/air supply.10. Performance of non-bio-degradable wasteejection system. Its effectiveness andreliability.a) Check operation of flapper/ ball valve,
whether working Satisfactorily (Yes/No).If No, Give reason & remarks formalfunctioning.
b) Chocking of toilet pan/ P-Trap (Yes/No)If yes, Give reason & remarks forChocking.
11. Tank evacuation date (if any) with coachnumber and date.
12 Details of attention/maintenance requiredwith coach number, date and time taken.
13 Adequacy of strength & capacity of Wastetreatment tank.
Consolidated trial report shall be sent by monitoring Railway to RDSO at theinterval of 6 months inthe prescribed format at Annexure II.
3. QUALITY CHECK OF THE EFFLUENT DISCHARGED FROM BIO TOILET
3.1 Sampling:.
i) Sample shall be collected from the toilet retention tanks sampling port inthe nominated coaching depot/washing line on quarterly basis.
ii) Samples will be collected randomly from lot of 5% coaches of the totalcoach holding but minimum one coach of each type.
iii) Sampling will start after coach is put into passenger service for 10 days ormore.
iv) The samples should be collected as per specified detailed samplingprocedure given in Annexure-III and sealed in the presence of railwayrepresentative.
3.2 Test Parameters:
For the quality check of effluent discharged from Bio-toilets, followingparameters shall be tested.
SN Parameter (as perAPHA Test Method).
RecommendedValues
In-house/Govt. Lab
1 pH 6 to 9 In-house /Govt. Lab2 Total Solids Max 750mg/100ml In-house /Govt. Lab3 TDS 350mg/100 ml max. In-house /Govt. Lab4 COD levels Max 2000 ppm Govt. Lab
5. Volatile Solids Max 500mg/100ml In-house /Govt. Lab6. Faecal Coliform
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
107/202
1'4
3.3 Testing Procedure:
i) Samples collected may be divided in two category one for In-house testingand second for Govt. Accredited Lab.
ii) The samples marked for Govt. Lab testing shall be transported to thenearest Govt. Accredited testing Labs listed in Annexure IVat the earliest.However prior consent for testing of the samples shall be required by therespective railway from such Govt. Approved Lab.
iii) Samples marked for in-house testing shall be tested as per test procedureattached at Annexure V
iv) The test results shall be furnished in prescribed format attached as
Annexure-I.
v) The necessary record of monitoring and testing should also be maintained
& kept in the concerned depots in the format of Annexure I.vi) In case of samples not meeting the requirements, tests will be repeated
after taking necessary corrective actions within a fortnight.
Consolidated all the test reports (In-House/Govt. Approved Labs ) of effluentdischarge shall be submitted to RDSO on Six monthly basis.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
108/202
1'
Annexure-I
Date of Sampling: ..................... Date of Lab Testing: .......................
Observations/Results
CoachNo.
Variant of
Bio-digester
pHValue
Total Solids(mg/100ml)
TDS
(mg/ 100ml)
CODLevel
(ppm)
VolatileSolids
(mg/100ml)
FaecalColiformCount
(MPN/100ml)
Signature of Evaluating Authority :
Name & Designation :
Seal :
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
109/202
1'#
Field Trial of Bio-Toilet (IR-DRDO Technology) on Indian Railway Passeng
Train No Rake No. Coach No. ....DateName of SE/ JE R/ Ma
Parameters to be checkedSl.
No. Coach no.
1. Thorough inspection of mounting / securing arrangement for the bio-digester tank.
2. Any leakage in joints/ connections in the complete system includingretention tank, water pipe line.
3. Adequacy of the provisions made for segregation of non bio-degradableitems.
4. Functionality of flush buttons/ lever & water tabs
Adequacy of the flushing of the pan5.
(a) By using pressurized flushing(b) By normal manual flushing
6. Any mal odour/ stench: (yes/No),if yes, please specify Light, medium or Heavy
7. Overall cleanliness level of the toilet room.
8. Notices for users and maintenance personal in Hindi/English & regionallanguage of the originating & destination station.
9. Emergency operation of flush arrangement without power / air supply.
10. Performance of non-bio-degradable waste ejection system itseffectiveness and reliability.a. Check operation of flapper / Ball valve whether working satisfactorily
(Yes/ No),If no, give reasons and remarks for malfunctioning.
b. Choking of toilet pan/ P-Trap (Yes/ No),If yes give reasons and remarks for choking.
11. Tank evacuation date (if any) with coach No. and date.
12. Details of attentions / maintenance required with coach no. , date andtime taken for maintenance.
13. Adequacy of strength & capacity of waste treatment tank
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
110/202
1')
Annexure-III
EFFLUENT SAMPLING PROCEDURE
Objective: Procedures to be followed for collection of valid and representative effluentsamples from bio-digester.
Scope: This document contains the procedure that should be followed to collect eff luentsamples from bio-digester for analysis of physiochemical and biologicalparameters. The sample size is small enough in volume to be transportedconvenientlyand yet large enough for analytical purposes.
Requirements:
Sample container -Autoclavable plastic (polyethylene or equivalent) /Glass
container marked in red/black for eff luent samples.
Refrigerator -For storage of samples.
Description:
General Requirements:
Ensure all sample equipment and containers are clean and quality assured before use.
Use sample containers that are clean and free of contaminants.
Fill sample containers without pre-rinsing with sample; pre-rinsing results in loss of anypre-added preservative and sometimes can bias results high when certain components
adhere to the sides of the container.). Leave an air space approximately 10% of the container volume to allow for thermal
expansion during shipment.
Collect samples 2-3 times from the same source with 2 minutes interval between eachof them and make composite sample, take necessary amount and use it for analysis.
Make record of every sample collected and identify every bottle with a unique samplenumber, preferably by attaching an appropriately inscribed tag or label.
In unique identification number write/mention name of the sampler, date of samplecollection, train No/Name of sample, coach no, toilet no.
Use water proof ink to record all information (preferably with black, non solvent basedink).
Maintain the sampling information in bound sample log book at the sampling site at thetime of sample collection.
Always prohibit eating, drinking, or smoking near samples, sampling locations, and inthe laboratory.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
111/202
1'7
Collection of samples:
1. Sample collection guidelines: Collect sample from the bio-digester 30 minutes after the train becomes stationery/still.
Sample should be collected from sampling port only, in case sampling port is not there,
can be collected from effluent discharge port. If water is not draining from sample port remove the debris which may plugged the
sample port by iron wire and let i t drain for 2 minutes and collect composite sample.
Even after cleaning of sampling port, if water is not draining from sample port, flush mildsteam of water with intermittent pause for 5 minutes into the bio-digester. Collectcomposite sample.
Too much of water also should not be flushed.
2. Type of sample Composite sampling may be done by combining small portions of multiple grab samples
taken from the same Bio-digester.
Collect individual portions in a wide mouth bottle every 2 min and mix it at the end of thesampling period or combine in a single bottle as collected.
3. Sampling methods Manual sampling may be used for routine sampling programmes.
Trained field technician is often necessary for sample collection.
4. Sample containers: Containers are typically made of plastic (PTFE Poly Tetra Fluoro Ethylene) or glass
may be used. The containers cap should made of foil or PTFE liners.
In rare situations it may be necessary to use containers not specifically prepared foruse, or otherwise unsuitable for particular situation.
Please thoroughly document these situations.
For QA purposes the inclusion of a bottle blank may be necessary.
5. Number of samples: Because of variability from analytical and sampling procedures (i.e. population
variability) small number of samples is insufficient to reach any reasonable desired level
of confidence.
Minimum three consecutive sampling has to be done from same Bio-toilet to drawconclusion.
6. Sample volume: Collect 1 L of sample for most physical and chemical analyses.
Always collect enough sample volume in appropriate container in order to comply withsample handling, storage and preservation requirements.
-
8/13/2019 Compendium on IR-DRDO Biotoilets for Indian Railways
112/202
1'8
7. Check the sample for the following:Quantity -Does the sample have sufficient quantity (500 -1000ml)Label -Label on the container should bear the following details:
Name of sample/train no, Date of collection, Sample no.Integrity of the seal across the sample should be checked.
8. Person handling the sample:
If leakage is observed, wipe the container with cotton soaked in spirit and transfer thespecimen into a new