Communication modules...IEC 62056-21 (7E1), DLMS (8N1), Mode C, Mode E, transparent 300 up to 19200...

2
EMH metering GmbH & Co. KG Neu-Galliner Weg 1 19258 Gallin GERMANY Tel. +49 38851 326-0 Fax +49 38851 326-1129 E-mail [email protected] Web www.emh-metering.com EN EMH metering GmbH & Co. KG • Neu-Galliner Weg 1 • 19258 Gallin • GERMANY • Tel. +49 38851 326-0 • [email protected] • www.emh-metering.com Edition: 12.12.2017 XCModule-H-DAB-E-1.00 Modem module: VARIOMOD XC Interface module: Interface Module XC for plug-in into the LZQJ-XC VARIOMOD XC Transparent data readout, suitable for all common control centres Extensive push functions Password protection (readout and/or remote configuration) Additional RS485 interface Exchangable during the meter operation Monitoring of data volume enables complete cost control Remote access for update and configuration possible Interface Module XC Interface extension for the LZQJ-XC RS485- and RS232 interface Exchangable during the meter operation Communication modules RS485 RS232 Analog GPRS Ethernet New antenna interface (FAKRA) for GPRS

Transcript of Communication modules...IEC 62056-21 (7E1), DLMS (8N1), Mode C, Mode E, transparent 300 up to 19200...

EN

EMH meteringGmbH & Co. KG

Neu-Galliner Weg 119258 GallinGERMANYTel. +49 38851 326-0Fax +49 38851 326-1129

E-mail [email protected] www.emh-metering.com

EN

EMH metering GmbH & Co. KG • Neu-Galliner Weg 1 • 19258 Gallin • GERMANY • Tel. +49 38851 326-0 • [email protected] • www.emh-metering.com

Edition: 12.12.2017XCModule-H-DAB-E-1.00

Modem module: VARIOMOD XCInterface module: Interface Module XCfor plug-in into the LZQJ-XC

VARIOMOD XC Transparent data readout,

suitable for all common control centres

Extensive push functions

Password protection (readout and/orremoteconfiguration)

Additional RS485 interface

Exchangable during the meter operation

Monitoring of data volume enables complete cost control

Remote access for update and configurationpossible

Interface Module XC Interface extension for the LZQJ-XC

RS485- and RS232 interface

Exchangable during the meter operation

Communication modules

RS485

RS232

Analog

GPRS

Ethernet

New antenna interface (FAKRA) for GPRS

VARIOMOD XCgprs VARIOMOD XCethernet VARIOMOD XCanalog Interface Module XCSupply from the LZQJ-XC (optionally with external

plug-inpowersupply)from the LZQJ-XC (optionally with external

plug-inpowersupply)from the LZQJ-XC (optionally with external

plug-inpowersupply)from the LZQJ-XC (optionally with external

plug-inpowersupply)Displays 3 LEDs 3 LEDs 3 LEDs ---Data interfaces electrical data interface

data protocols

transmission rates

RS485IEC62056-21(7E1),DLMS(8N1),

Mode C, Mode E, transparent300 up to 19200 baud

RS485IEC62056-21(7E1),DLMS(8N1),

Mode C, Mode E, transparent300 up to 19200 baud

RS485IEC62056-21(7E1),DLMS(8N1),

Mode C, Mode E, transparent300 up to 19200 baud

RS485 and RS232IEC62056-21(7E1),DLMS(8N1),

Mode C, Mode E, transparent300 up to 19200 baud

Safety/EMC noise immunityradio disturbance

EN301489-1,EN301489-7EN301489-1,EN301489-7

EN55024EN55032

EN55024EN55032

EN55024EN55032

Temperature range specifiedoperatingrangelimit range for operation,storage and transport

-20°C...+55°C

-40°C...+80°C

-25°C...+55°C

-40°C...+80°C

-25°C...+55°C

-40°C...+80°C

-25°C...+55°C

-40°C...+80°CRelative humidity max. 95%, non-condensing max. 95%, non-condensing max. 95%, non-condensing max. 95%, non-condensingHousing dimensions

mountingdegree of protection: housing

approx.45x105/115x27(WxHxD)mmplug-in into module compartment of LZQJ-XC

IP 20

approx.45x105x27(WxHxD)mmplug-in into module compartment of LZQJ-XC

IP 20

approx.45x105x27(WxHxD)mmplug-in into module compartment of LZQJ-XC

IP 20

approx.45x105x27(WxHxD)mmplug-in into module compartment of LZQJ-XC

IP 20Weight approx. 90 g approx. 65 g approx. 60 g approx. 60 gTerminals RS485

RS232telephone connectionantenna connectionnetwork connectionexternal supply unit

RS485 with spring terminal block

1xRJ12modularsockets(6P6C)plus 1 x socket for 1,5 mm2 spring terminal,

can be looped trough------

FAKRA plug---

12 - 18 V DC

2x RJ12 modular sockets (6P6C),loopedtrough

or 2,5 mm² spring terminal------

RJ45modularsocket(8P8C)12 - 18 V DC

2x RJ12 modular sockets (6P6C),loopedtrough

or 2,5 mm² spring terminal---

RJ12modularsocket(6P6C)------

12 - 18 V DC

2x RJ12 modular sockets (6P6C),loopedtrough

or 2,5 mm² spring terminalRJ12modularsocket(6P6C)

---------

12 - 18 V DC

Functions call acceptancepassword protection

configuration+firmwareupdate

operation safety

---2 independent password levels,

configurationandtransparentmodevia GPRS or

locally via electrical data interfacesintegrated watchdog,

automaticreset(configurable)

---2 independent password levels,

configurationandtransparentmodevia Ethernet or

locally via electrical data interfacesintegrated watchdog,

automaticreset(configurable)

via time slots2 independent password levels,

configurationandtransparentmodevia telephone network or

locally via electrical data interfacesintegrated watchdog,

automaticreset(configurable)

------

---

---

GSM wavelengthtransmission performance

quad band 850 / 900 / 1800 / 1900 MHzmax. 2 W with 850 / 900 MHz

max. 1 W with 1800 /1900 MHz

------

------

------

GPRS class class 10up to 2 uplinks, up to 4 downlinks;

maximum 5 links

--- --- ---

Network Ethernet

IP address allocation mode

data transmission

---

to be automatically generated by the provider (PPP)

TCP/IP Server, FTP, UDP, SMS

IEEE 802.3 10BaseT/100BaseTx autonegotiation,Auto-MDI(X)DHCPorfixedIP-address

TCP/IPServer,FTP,IPT,SMTP(Mail)

---

---

---

---

---

---Scope of delivery connectioncable(standard)

softwaredocuments

---Variomod ManagerInstructions for use

---Variomod ManagerInstructions for use

TAE-Nplug,3mVariomod ManagerInstructions for use

------

Instructions for useAccessory magnetic base antenna 2,5 m cable length,

station antenna 3 m or 5 m cable length, RJ12 connection cable,RJ12 cable with open-ended

cableplug for 1,5 mm2(RS485)

RJ12 connection cable, RJ12 cable with open-ended cable

RJ12 connection cable, RJ12 cable with open-ended cable

RJ12 connection cable,RJ12 cable with open-ended cable

Only valid for generation H: --- --- ---

Productspecificationsaresubjecttochangewithoutnotice!

The modem module VARIOMOD XC is available as an GPRS-, Ethernet- and Analog-modul. Due to the possibility of transparent data readout the modem modules are suitable for all common control centres.The modem modules are equipped with a RS485-interface.

The VARIOMOD XC functions can be extented with the following accessories:

external rod antenna magnetic base antenna

Modem module: VARIOMOD XC

Konfigurationsoftware

RS485(RJ12) RS485(RJ12)/extern. supply unit

Ethernet(RJ45) RS485(RJ12) RS485(RJ12)/extern. supply unit

RS232(RJ12) RS485(RJ12) RS485(RJ12)/extern. supply unit

RS485

4 1

Ethernet(RJ45)

12 5

RS485

4 1

PSTN(RJ12)

10 5

Antenna (with FAKRAplug)

RS485 socket with spring terminals

PSTN(RJ12)

7 1

RS485(RJ12)/external supply unit

RS485plug

3 1

Ethernet

Analogue

New

antenna

interface

(FAKRA)

for GPRS RS485

RS232 RS485