COMMERCIAL ROOFING - IKO€¦ · Thank you for considering IKO Premium Roofing products. For...

4
Diamond Shield L&M WARRANTY PROGRAMS C O M M E R C I A L R O O F I N G

Transcript of COMMERCIAL ROOFING - IKO€¦ · Thank you for considering IKO Premium Roofing products. For...

Page 1: COMMERCIAL ROOFING - IKO€¦ · Thank you for considering IKO Premium Roofing products. For additional information on IKO’s full line of superior Commercial/Industrial Roofing

Diamond Shield

L&M

WARRANTY PROGRAMS C O M M E R C I A L R O O F I N G

Page 2: COMMERCIAL ROOFING - IKO€¦ · Thank you for considering IKO Premium Roofing products. For additional information on IKO’s full line of superior Commercial/Industrial Roofing

IKO L&M WARRANTY PROGRAM FOR BUILT UP ROOFING

SURFACING FLASHINGS

5 Year

4 Ply No. 15 Single Pour2 Ply Mod-Bit

3 Ply No. 15 & 180 or 250 Cap4 Ply No. 15

10 Year

4 Ply No. 15 Single Pour 2 Ply Mod-Bit

4 Ply Type IV Single Pour 2 Ply Mod-Bit

4 Ply Type 6 Single Pour 2 Ply Mod-Bit

15 Year

1 Ply 95 or 180 & 3 Plies Type IV Single Pour 2 Ply Mod-Bit

1 Ply 95 or 180 & 3 Plies Type 6 Single Pour 2 Ply Mod-Bit

20 Year

1 Ply 180 & 4 Plies of Type IV Single Pour 2 Ply Mod-Bit

1 Ply 180 & 4 Plies of Type 6 Single Pour 2 Ply Mod-Bit

** Flashings are 2 Ply Polyester

IKO L&M WARRANTY PROGRAM FOR MOD-BIT ROOFING

BASE SHEET CAP SHEET

10 Year

95 180 or 250 or ArmourCool or Prevent 250 or HD Cap

180 180 Base with Pour & Gravel

15 Year

180 250 or ArmourCool or Prevent 250 or HD Cap

HD 250 or ArmourCool or Prevent 250 or HD Cap

Fast-N-Stick 250 or ArmourCool or Prevent 250 or HD Cap

ArmourBond (Flash or 180) 250 or ArmourCool or Prevent 250 or HD Cap

ArmourVent 250 or ArmourCool or Prevent 250 or HD Cap

Cold Gold Base 250 or Prevent 250

20 Year

180 250 (5.0) or ArmourCool or Prevent 250 or HD Cap

HD 250 (5.0) or ArmourCool or Prevent 250 or HD Cap

Fast-N-Stick 250 (5.0) or ArmourCool or Prevent 250 or HD Cap

ArmourBond 180 250 (5.0) or ArmourCool or Prevent 250 or HD Cap

** Flashings are 2 Ply Polyester

Limited Labour and Membrane

Warranty (L&M)

This limited warranty is applicable to

commercial systems installed by an

IKO Registered Roofing Contractor

on commercial / industrial buildings.

The L&M is not pro-rated and covers

manufacturing defects resulting in

roof leaks and has a non-prorated

labour inclusion for IKO to pay for the

repair / replacement of the defective

material. To obtain an L&M warranty the

contractor must be an IKO Registered

Roofing Contractor and possess current

liability insurance. The contractor

should completely fill-out the limited

warranty application and submit it to

IKO Technical Services / Commercial

Warranties for processing.

Page 3: COMMERCIAL ROOFING - IKO€¦ · Thank you for considering IKO Premium Roofing products. For additional information on IKO’s full line of superior Commercial/Industrial Roofing

IKO DIAMOND SHIELD WARRANTY PROGRAM FOR BUILT-UP ROOFING

SURFACING FLASHINGS

10 Year

4 PlyType IV Single Pour 2 Ply Mod-Bit

4 Ply Type 6 Single Pour 2 Ply Mod-Bit

15 Year

1 Ply 95 or 180 & 3 Plies Type IV Single Pour 2 Ply Mod-Bit

1 Ply 95 or 180 & 3 Plies of Type 6 Single Pour 2 Ply Mod-Bit

20 Year

1 Ply 180 & 4 Plies Type IV Single Pour 2 Ply Mod-Bit

1 Ply 180 & 4 Plies of Type 6 Single Pour 2 Ply Mod-Bit

** Flashings are 2 Ply Polyester

IKO DIAMOND SHIELD WARRANTY PROGRAM FOR MOD-BIT ROOFING

BASE SHEET CAP SHEET

10 Year

95 180 or 250 or ArmourCool or Prevent 250 or HD Cap

180 180 Base with Pour & Gravel

15 Year

180 250 or ArmourCool or Prevent 250 or HD Cap

HD 250 or ArmourCool or Prevent 250 or HD Cap

Fast-N-Stick 250 or ArmourCool or Prevent 250 or HD Cap

ArmourBond (Flash or 180) 250 or ArmourCool or Prevent 250 or HD Cap

ArmourVent 250 or ArmourCool or Prevent 250 or HD Cap

Cold Gold Base 250 or Prevent 250

20 Year

180 250 (5.0) or ArmourCool or Prevent 250 or HD Cap

HD 250 (5.0) or ArmourCool or Prevent 250 or HD Cap

Fast-N-Stick 250 (5.0) or ArmourCool or Prevent 250 or HD Cap

ArmourBond 180 250 (5.0) or ArmourCool or Prevent 250 or HD Cap

** Flashings are 2 Ply Polyester

Diamond Shield Limited Warranty

The Diamond Shield Limited Warranty

is applicable to commercial systems

installed on a commercial / industrial

building by an IKO Registered Roofing

Contractor with current liability

insurance. The Diamond Shield Warranty

is not pro-rated and covers repair or

replacement of the IKO commercial /

industrial roofing products without

cost to the Owner. Please refer to the

Diamond Shield Limited Warranty or

contact your local IKO representative

for information on the supporting

documentation required for warranty

issuance. A Diamond Shield Limited

Warranty is assessed a fee based on

roof size and warranty term requested.

Please refer to a sample copy of the

Diamond Shield Limited Warranty for

further information.

Note: The coverage is not prorated. (reference Canadian Commercial & Industrial Limited Warranty

Chart for details) The Diamond Shield application should be sent to IKO at least two weeks prior to

job commencement and include a copy of the roof schematic, roof details (flashings, penetrations etc.)

and written specification to ensure that the proposed system complies with IKO requirements.

DIAMOND SHIELD WARRANTY FEES

TERM FEES

5 Years $ 0.06 / sq.ft. min. $ 600.00

10 Years $ 0.11 / sq.ft. min. $ 900.00

15 Years $ 0.15 / sq.ft. min. $ 1,200.00

20 Years $ 0.20 / sq.ft. min. $ 2,000.00

Page 4: COMMERCIAL ROOFING - IKO€¦ · Thank you for considering IKO Premium Roofing products. For additional information on IKO’s full line of superior Commercial/Industrial Roofing

Thank you for considering IKO Premium Roofing products.

For additional information on IKO’s full line of superior Commercial/Industrial Roofing and Waterproofing products

please call: 1-855-IKO-ROOF (1-855-456-7663), or visit our web site at: www.iko.com

Note: The information in this document is subject to change without notice.

IKO assumes no responsibility for errors that may appear in this document.

© Copyright 11/13 · MM1L189

IKO offers a range of commercial roofing warranties from pro-rated Limited Material Warranties

to Diamond Shield Limited Warranties which cover materials and workmanship.

Regarding the Limited Material Warranty coverage, the contractor does not need to be registered

or approved in any way by IKO. The warranty is issued through dealers, and only requires the

contractor’s signature to be valid.

The Limited Labour and Membrane Warranty and the Diamond Shield Limited Warranty require

the contractor’s company be an IKO Registered Roofer. Information on registration procedures

and required training programs can be obtained from your roofing products distributor, or your

IKO Representative.

Please ask your IKO Technical Service Manager for specific

information and processing details for the level of warranty

coverage you require.

Correspondence and questions should be directed to:

IKO Technical Services

Commercial Warranties

80 Stafford Drive, Brampton, ON

Phone: 1-888-766-2468

email: [email protected]

IKO Commercial Roofing Warranties:

Application for Limited Diamond Shield Warranty  

MM3L203_1013  

1. Roofer  Company: ___________________________________________________________________________ Ph.#: ______________________________  2. Address: __________________________________________________________________________________  Fax  #: ____________________________  3. Roofer’s  IKO  Registration  No.:  (SPECIFY  BUR  OR  MODBIT) ____________________________________________________________________________  4. Insurance  Co.  &  Policy  #: _____________________________________________________________________ Policy  Expiry  Date: __________________  5. Building  Owner’s  Name: _____________________________________________________________________ Ph.#: ______________________________  6. Address: __________________________________________________________________________________ Fax  #: _____________________________  7. Name  of  Building: _______________________________________________________________________________________________________________  8. Installation  Address: _____________________________________________________________________________________________________________  9. Intended  Use: __________________________________________________________________________________________________________________  10. Roofing  Material  Distributor: ______________________________________________________________________________________________________  11. Consultant/Inspector: _________________________________________________________________________ Ph.#: ______________________________  12. Address: ___________________________________________________________________________________ Fax  #: _____________________________  13. Architect/Specifier: __________________________________________________________________________ Ph.#: _____________________________  14. Address: __________________________________________________________________________________ Fax: _______________________________  

ROOF  DESIGN,  ROOF  SIZE  &  BUILDING  DIMENSION  INFORMATION  

15. Installation  Size  (square  feet): __________________________________________________ 16.  Roof  Slope%: _____________________________________  17.  Parapet  Height  (inches): _______________________________________________________ 18.  Building  Height  (feet): ______________________________  

ROOF  TYPE,  DECK  TYPE  &  EXISTING  CONSTRUCTION  

19.  Roof  Construction  Type:   ☐New Construction ☐Re-cover (no tear-off) ☐Complete tear-off ☐Partial tear-off (explain with cover letter)

20.  Roof  Deck:    ☐Steel ☐Structural Concrete ☐Wood Plank ☐Plywood ☐Other: _________________ Gauge, PSI, Thickness: __________________

21.  Existing  Insulation:   ☐Fibreglass ☐Perlite ☐Fibreboard ☐Isocyanurate ☐Other (specify): _____________________ Thickness: __________________  

22.  Existing  Roof: ☐EPDM ☐BUR (☐gravel ☐smooth) ☐Coal Tar Pitch ☐Mineral Cap ☐Sprayed Urethane ☐Other (specify) __________________

NEW  THERMAL  INSULATION,  NEW  COVERBOARD  &  NEW  INSULATION  ASSEMBLY  ATTACHMENT  

23.  Vapour  Barrier/Retarder: _______________________________ ☐None   24.  IKO  Thermal  Insulation:   ☐IKOTherm ☐None ________________ 25.  Sloped  Thermal  Insulation:  Manufacturer: _____________________________________________________________________________________________  ☐Isocyanurate ☐Expanded ☐Polystyrene ☐Fibreglass ☐Perlite ☐Extruded Polystyrene ☐Composite ☐Type X Gypsum

Other (specify): ______________________________________________________________ 26.  IKO  Insulation  Overlay  ☐CoverShield ☐Protectoboard ☐None

27.  Sloped  Insulation  Overlay:  Manufacturer ___________________________________ ☐Fibreboard ☐Perlite ☐Fibreglass ☐Other (specify) _______________  

28.  Thermal  Insulation  Attachment  (if applicable): ☐Asphalt ☐Adhesive☐Mechanically Fastened (accepted fasteners) Fastening Rate: _____________________  

29.  Insulation  Overlay  Attachment (if applicable): ☐Asphalt ☐Adhesive ☐Mechanically Fastened (accepted fasteners) Fastening Rate: ____________________

INSULATION  &  BASE  SHEET  FASTENERS  /  ASPHALT  

30.  Fastener  Manufacturer: _____________________________ Fastener  Type: __________________________ Fastener  Length  (inches): ____________________  31.  Asphalt  Manufacturer:  ☐IKO  ☐Other  (specify) __________________________________ 32.  Asphalt  Type: ☐Type I ☐Type II ☐Type III  

33.  Cold  Adhesive  System:  ☐IKO  Cold  Gold  ☐Other  Adhesive  Manufacturer  &  Type: ________________________________________________________________  33.  IKO  Primers  Used: _______________________________________________________________________________________________________________  

MEMBRANE  ASSEMBLY:  BASE  SHEETS,  PLY  SHEETS  &  CAP  SHEETS  

35.  Base  (if  applicable) (e.g. Modiflex MF-95-FS): _________________________________________________________________________________________ 36.  Ply  Sheets  (if  applicable)  (e.g. Type IV Glass Ply): ______________________________________________________________________________________  37.  Cap  Sheet  (if  applicable)  (e.g. Torchflex TP-250-CAP): ___________________________________________________________________________________  38.  Base  Flashing  (e.g. Armourbond Flash): ______________________________________________________________________________________________  39.  Cap  Flashing  (e.g. Torchflex TP-180-CAP): ____________________________________________________________________________________________  

SURFACING:  COATING  /  AGGREGATE  

40.  Coating: Manufacturer: __________________ Type: _________________ 41.  Gravel  Type  /  Green  Roof: ___________________ lbs./sq. ft. ______________  42.  Modular  Green  Roof  (MGR)  Modules  (Size and number): _________________________________________________________________________________ 43. Other products used, not listed above (eg. Primers, bitumen, cafts, etc.): ____________________________________________________________________  I understand that this warranty will be null and void if any of the information above is inaccurate. By signing this application form, I hereby acknowledge that I have read, understood, and complied with the terms and requirements of the IKO Limited Warranty being applied for. I further acknowledge that for DSLW’s I am responsible for any workmanship deficiencies occurring in the initial 2 years of warranty coverage, and all workmanship deficiencies for all other IKO warranties.

Officer: ____________________________________ Date: ______________________________________ IKO Sales Rep: _____________________________ Roof Accessibility: ☐No Ladder Needed ☐Ladder at Job Site ☐Ladder will be provided by roofing contractor

Project Starting Date: ___________________ Approximate Project Completion Date: ____________________ Warranty Period applied for: __________________ mm/dd/yyyy mm/dd/yyyy years NOTE:    OFFICIAL  DATE  OF  SUBSTANTIAL  COMPLETION  OF  ROOF  MEMBRANE  MUST  BE  FORWARDED  TO  IKO  AFTER  ROOF  IS  DONE    For  this  warranty  to  be  valid,  IKO,  the  Distributor  and  the  Roofer  must  pay  in  full  for  materials  and/or  labour.    

THIS  COMPLETED  FORM  SHOULD  BE  FORWARDED  TO  THE  ATTENTION  OF:    IKO  COMMERCIAL  WARRANTIES,  80  STAFFORD  DRIVE,  BRAMPTON,  ONTARIO  L6W  1L4.  FAX  COPIES  ARE  ALSO  PERMITTED.  FAX  TO  (905)  457-­‐3196  OR  EMAIL:  [email protected]