  • column covers

  • 2 WWW.ATAS.COM

    NOTE HOW INTERIOR STRUCTURE MAY VARY

    Column Covers

    COLUMN COVERS

    MINIMUM 12” DIAMETER FROM .090 OR .125 ALUMINUM HAVING A 70% PVDF/HYLAR 5000® PVDF FINISH IN A WIDE RANGE OF 31 STANDARD COLORS.

    THESE COLUMN COVER ASSEMBLIES ARE FURNISHED IN CUSTOM LENGTHS. COLUMNS OVER 12’-0” IN HEIGHT REQUIRE STACKED UNITS WITH HORIZONTAL HAIRLINE OR REVEAL JOINTS (see detail C-C & B-B).

    REQUIRED ON SERIES UTILIZING THE HIDDEN FASTENER SYSTEM. (VERTICAL JOINT SYSTEM)

    WITH VERTICAL REVEAL JOINT

    5/8”OVERHEADSTRUCTURE

    A A

    STANDARD ELEVATIONN.T.S.

    WITH VERTICAL HAIRLINE JOINT

    1/8”FLOOR

    OVERHEADSTRUCTURE

    A A

    B

    B

    FLOOR1/8”STANDARD ELEVATION

    N.T.S.

    WITH VERTICAL REVEAL JOINT

    Column covers

  • 800.468.1441 3

    ATAS

    C - C

    A - A

    FASTENING LEGS TO BE PARALLEL. COLUMN COVER SHALL HAVE A FLUSH APPEARANCE FROM THE OUTSIDE. PLEASE NOTE: THIS STYLE REQUIRES 5/8” MINIMUM CLEARANCE ABOVE TOP OF COLUMN COVER.

    HIDDEN FASTENER#10 DIA. R.H. SCREWNUT AND LOCKWASHERW/ TAPERED WASHER(BY ATAS)

    COLUMN COVER

    1 1/

    4”

    1 3/

    4”

    VERTICAL JOINT DETAIL C - CN.T.S.

    VERTICAL REVEAL DETAIL A - AN.T.S.

    VERTICALREVEALINSERT

    ALUM.ANGLES

    COLUMNCOVER

    SUPPORT FRAMINGAS REQUIRED(BY OTHERS)

    1”

    5/8”

    ORIENTATION OF VERTICAL JOINTS SHALL BE

    ACCOMPLISHED IN FIELD BY INSTALLER, AND SUBJECT TO

    ARCHITECT’S APPROVALANGLE SUPPORTS AND FASTENERSAT 24” O.C. MAX. (NOT BY ATAS)SEE TYPICAL ATTACHMENT DETAIL

    SEE VERTICALJOINT DETAIL A

    COLUMN COVER

    COLUMN COVER PLAN VIEW

    vertical jointures

  • ATAS International, Inc. Allentown, PA | Mesa, AZ

    www.atas.com800.468.1441

    (IF VERTICAL HAIRLINE JOINT SYSTEM IS USED)

    DETAIL B - B

    TOP REVEAL MID REVEAL

    MUST HAVE AT LEAST 5/8” BETWEEN TOP OF COLUMN COVER AND STRUCTURE ABOVE (FOR VERTICAL HAIRLINE JOINT SYSTEM)

    TOP

    REV

    EAL

    5/8”

    ALUM. CHANNEL

    COVER

    COLUMN

    TOP DETAILN.T.S.

    MID REVEALN.T.S.

    5/8”

    ALUM. CHANNEL

    MID

    REV

    EAL

    COVER

    COLUMN

    BASE DETAILN.T.S.

    ALUM. CHANNEL

    5/8”

    BASE

    REV

    EAL

    BASE REVEAL

    COVER

    COLUMN

    SEE SCHEDULE

    OVERHEADSTRUCTURE

    SEE TYPICALATTACHMENT DETAIL A

    5/8”

    1/8”COLUMN COVER SECTION

    N.T.S.

    FLOOR

    SEE VERTICAL JOINTDETAIL A

    SEE TYPICAL COLUMN COVER PLAN VIEW

    CO

    LUM

    N C

    OVE

    R L

    ENG

    TH (C

    .C.L

    .)SE

    E SC

    HED

    ULE

    special jointures