Collaboration of TE-VSC-SCC with straw working group NA62
description
Transcript of Collaboration of TE-VSC-SCC with straw working group NA62
![Page 1: Collaboration of TE-VSC-SCC with straw working group NA62](https://reader035.fdocuments.us/reader035/viewer/2022071808/56813155550346895d97ce14/html5/thumbnails/1.jpg)
Collaboration of TE-VSC-SCC with straw working group NA62
Wil Vollenberg TE-VSC-SCC
NA62 straw working group meeting; 01-02-2010 Wil Vollenberg
Presentation of techniques of ongoing and planned activities: Coating and permeation
measurements
![Page 2: Collaboration of TE-VSC-SCC with straw working group NA62](https://reader035.fdocuments.us/reader035/viewer/2022071808/56813155550346895d97ce14/html5/thumbnails/2.jpg)
DMSDC Magnetron sputteringplanar configurationØ 600 mmAfter bake: 2*10-9 mbar
2 magnetrons Ø 150 mmup to 5 samplesØ120 mm: +/- 10 %
Wil Vollenberg
Coating of PET by magnetron sputtering
NA62 straw working group meeting; 01-02-2010
![Page 3: Collaboration of TE-VSC-SCC with straw working group NA62](https://reader035.fdocuments.us/reader035/viewer/2022071808/56813155550346895d97ce14/html5/thumbnails/3.jpg)
Cu coating of different thickness on several samples in one run.
Wil Vollenberg
Coating of PET by magnetron sputtering
NA62 straw working group meeting; 01-02-2010
![Page 4: Collaboration of TE-VSC-SCC with straw working group NA62](https://reader035.fdocuments.us/reader035/viewer/2022071808/56813155550346895d97ce14/html5/thumbnails/4.jpg)
Wil VollenbergNA62 straw working group meeting; 01-02-2010
Permeation measurementreference
test
Absolute measurementRelative measurement
AccumulationDynamic
24 – 48 hours