cm_flash
-
Upload
luana-dantas -
Category
Documents
-
view
214 -
download
0
Transcript of cm_flash
7/30/2019 cm_flash
http://slidepdf.com/reader/full/cmflash 1/2
Confidential and Proprietary Information of BMC Software, Inc.2101 CityWest Blvd., Houston, TX 77042-2827 • 713 918 8800
Technical Support: 800 537 1813 (USA and Canada) or contact your local support center
BMC Software, the BMC Software logos, and all other BMC Software product or service names are registered trademarks or trademarks of BMC Software,
Inc. All other registered trademarks or trademarks belong to their respective companies. Copyright © 2001 BMC Software, Inc., as an unpublished work. All
rights reserved.
CONTROL-M ® /Server for Unix
Flash
Version 6.0.0x
November 21, 2001
Tracking Number BMPM007542 – Incorrect path in the SybaseInitialization Script after Upgrade to CONTROL-M/Server version 6.0.03
Effected UsersUsers of CONTROL-M/Server for Unix version 6.0.01 (FD4000) with a Sybase database server on an AIX
computer - who are planning to upgrade to CONTROL-M/Server for Unix version 6.0.03 (FD4500).
ProblemAfter upgrading from version 6.0.01 to 6.0.03, the RUN script for the Sybase database contains an incorrect path.
If you are using a dedicated Sybase database server, Sybase will not restart after the upgrade procedure.
Workaround
Perform the following steps regardless of whether or not you are using a dedicated Sybase database server:
1. BEFORE starting the upgrade to version 6.0.03, copy the RUN script (located in <CONTROL-M
server>/sybase/install/ ) to a temporary location.
2. Perform the upgrade procedure as described in the CONTROL-M/Server for Unix Installation Guide version
6.0.03.
3. AFTER you have completed the upgrade procedure, restore the above saved copy of the RUN script to its
original location (<CONTROL-M server>/sybase/install/ ).
4. Use the startdb command to start the Sybase database.
This problem will be corrected in the next version of CONTROL-M/Server for Unix. If you have questions about
this problem, contact your BMC Software CONTROL-M technical support analyst at 800 537 1813 (USA orCanada) or call your local support center.
*100038581**100038581**100038581**100038581*
*100038581*
7/30/2019 cm_flash
http://slidepdf.com/reader/full/cmflash 2/2
Flash (continued)
CONTROL-M ® /Server for Unix November 21, 2001
Page 2 of 2 Confidential and Proprietary Information of BMC Software, Inc.
Where to Get the Latest Product InformationTo view the latest BMC Software documents, visit the support page on the BMC Software Web site at
http://www.bmc.com/support.html . Log on and select a product to access the related documentation. (To log on,
first time users can request a user name and password either by registering at the support page or by contacting a
BMC Software sales representative.)