Clinical Measurement Points - mindrockets

8
Taking Measurements of the RSC® Brace www.ortholutions.de Clinical Measurement Points Mark well visibly: 1. trochanter major 2. waist and dorsal spines 3. lumbal,thoracic and high thoracic apex 4. and other noticeable points 2 1 5 4 3

Transcript of Clinical Measurement Points - mindrockets

Page 1: Clinical Measurement Points - mindrockets

Taking Measurements of the RSC® Brace

www.ortholutions.de

ORTHOLUTIONS

ORTHOLUTIONS - www.ortholutions.com

Clinical Measurement Points

Mark well visibly:

1. trochanter major2. waist and dorsal spines3. lumbal,thoracic and high thoracic apex 4. and other noticeable points

21

543

Page 2: Clinical Measurement Points - mindrockets

www.ortholutions.de

ORTHOLUTIONS

ORTHOLUTIONS - www.ortholutions.com

Clinical photos for database

frontal plane:1. relaxed stance, hanging arms, make sure that arms don‘t hide the pelvis2. sagittal plane- line of sight to the right: relaxed stance, make sure that elbows don‘t

hide the back profile3. best option – 2 photos: one in relaxed stance and one with frontal crossed arms

frontal plane from dorsal:4. relaxed stance, hanging arms, make sure that arms don‘t hide the pelvis5. sagittal plane line of sight to the left (same like to the right)

21

4

3

65

Taking Measurements of the RSC® Brace

1

5

2

6

3

7

4

Page 3: Clinical Measurement Points - mindrockets

www.ortholutions.de

ORTHOLUTIONS

ORTHOLUTIONS - www.ortholutions.com

Clinical photos for database

• the camera has to be parallel to the grid wall and patient• if possible use Lasar posture ore other helpful accessories to project the plumbline • the measure points have to be apparent

NOTE:

• one photo should have between 150 and 250 kb• use JPG files to save and upload the photos into the data base

Taking Measurements of the RSC® Brace

Page 4: Clinical Measurement Points - mindrockets

www.ortholutions.de

ORTHOLUTIONS

ORTHOLUTIONS - www.ortholutions.com

Measurement form and measurements

1. circumference trochanter level: apply tape measure on the trochanter level 2. circumference waist: make sure that the abdomen is relaxed and not retracted3. circumference lower breast: directly under the breast with relaxed arms and

bridge the flatback4. circumference breast: on the level of the maximum prominent point of the

breast (t8)

When taking the static measurements the patient has to be in a relaxed stance- not in correction.

All measurements have to be taken loosely, the tape measure has to be aligned horizontally.

1

3 4

2

1

43

2

Taking Measurements of the RSC® Brace

Page 5: Clinical Measurement Points - mindrockets

www.ortholutions.de

ORTHOLUTIONS

ORTHOLUTIONS - www.ortholutions.com

Measurement form and measurements

L- L Measurements and lateral heights1. maximum prominence of trochanter major2. maximum distance of crista iliaca3. waist with a lightly compression4. horizontal distance at the axilla level5. trochanter major to iliac crest6. iIliac crest to axilla

1

4

32

5 6

43

61

52

Taking Measurements of the RSC® Brace

Page 6: Clinical Measurement Points - mindrockets

www.ortholutions.de

ORTHOLUTIONS

ORTHOLUTIONS - www.ortholutions.com

Measurement form and measurements

A-P measurements

1. direct distance from spina iliaca anterior to spina iliaca posterior2. maximum prominence of the bottom on trochanter level3. dorsolumbar prominence to ventral (make sure the abdomen is not retracted)4. xyphoid to the virtual end of the back 5. manubrium to virtual end of the back

1

5

32

5

4

4

2

4

3

1

5

Taking Measurements of the RSC® Brace

Page 7: Clinical Measurement Points - mindrockets

www.ortholutions.de

ORTHOLUTIONS

ORTHOLUTIONS - www.ortholutions.com

A-P measurement on manubrium and xyphoid level

NOTE:A-P measurement on manubrium and xyphoid leveldirect distance between manubrium/xyphid and processus spinosus plus 50% of the distance processus spinosus - most prominent point of thoracic apex

Taking Measurements of the RSC® Brace

Page 8: Clinical Measurement Points - mindrockets

www.ortholutions.de

ORTHOLUTIONS

ORTHOLUTIONS - www.ortholutions.com

Dynamic measurements

No. 1: horizontal distance from axillar pad to thoracic prominence (B to A)No. 2: direct diagonal distance from axillar pad to thoracic prominence (B to A)No. 3: trochanter to to thoracic apexNo. 4: trochanter to imaginary axillar pad (upper edge)No. 5: trochanter to lumbal apex

21

4

3

5

Taking Measurements of the RSC® Brace