![Page 1: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/1.jpg)
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
Gianfranco Iannaccone
www.latinoamerica.sisgeo.com
![Page 2: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/2.jpg)
INDEX
o Why dam monitoring?o TEL‐310 submergible pendulumo MEXID miniaturizedMPBXo BH profile inclinometerso DEX‐S automatic extenso‐inclinometerso OMNIAlog network data acquisition system
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 3: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/3.jpg)
WHY DAM MONITORING?
The most common causes of failure of operating dams are:• poor construction materials• geological instability• landslide into reservoir• poor maintenance• human, computer or design error• internal erosion (earth‐fill dams)• earthquakes Inadequate monitoring system
Vajont Dam, Italy
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 4: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/4.jpg)
PENDULUMS:APPLICATIONS IN ARCH AND GRAVITY DAMS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
Directpendulum
Invertedpendulum
![Page 5: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/5.jpg)
TEL-310 SUBMERGIBLE TELEPENDULUM:EXAMPLE OF APPLICATION IN ARCH DAM
Direct pendulum
Inverted pendulum
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 6: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/6.jpg)
TEL-310 SUBMERGIBLE TELEPENDULUM
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
WHAT HAPPEN IN CASE OF FLOODING INTO THE GALLERIES??
Telependulums and all their components will be submerged by water / mud
SISGEO TEL‐310 telependulum is the ONLY ONE in the market with IP68 protection (waterproof).
After flooding just clean the optical unit and run!
![Page 7: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/7.jpg)
TEL-310 SUBMERGIBLE TELEPENDULUM:MAIN FEATURES
X‐axis
Y‐axis
• Wide measuring range: 60x145mm;• Waterproof components
IP68 until 50kPa (5m water head);• Remote auto‐diagnostic through
“log file”;• High level built‐in software
for data elaboration and validation.
Datasheet: http://www.sisgeo.com/uploads/schede/schede/TEL310_EN_01_telependulum_telecoordinometer.pdf
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 8: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/8.jpg)
TEL-310: WIRING SCHEME
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
ALL the components (boxes, connectors, cables) are waterproof IP68 up to 50 kPa
![Page 9: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/9.jpg)
TEL-310: LOGGER ANALOGUE NETWORK
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015
![Page 10: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/10.jpg)
TEL-310: RS485-PC DIGITAL NETWORK
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015
![Page 11: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/11.jpg)
BOREHOLE EXTENSOMETERS (MPBX & MEXID):APPLICATION AND AIM
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
MPBX and MEXID can be installed in:
• dam foundations
• dam abutments
• rockfall / topple landslide over the reservoir
![Page 12: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/12.jpg)
BOREHOLE EXTENSOMETERS (MPBX & MEXID):APPLICATION IN ARCH AND GRAVITY DAMS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 13: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/13.jpg)
BOREHOLE EXTENSOMETERS (MPBX & MEXID):APPLICATION IN EMBANKMENT DAM
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 14: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/14.jpg)
BOREHOLE EXTENSOMETERS:WHY MEXID?
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
Sometimes to drill the borehole forMPBX become a problem or impossible:
Required drill hole:Ø 101 mm (4"), Ø140 mm (5.5”) first meter
![Page 15: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/15.jpg)
BOREHOLE EXTENSOMETERS:MEXID SOLUTION
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING 2015
Sometimes to drill the borehole forMPBX become a problem or impossible:
Required drill hole:Ø 101 mm (4"), Ø140 mm (5.5”) first meter
i.e.: DAM REHABILITATION
![Page 16: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/16.jpg)
BOREHOLE EXTENSOMETERS:MEXID SOLUTION
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
Required drill hole for MEXID:Ø 50 mm (2"), Ø 75 mm (3”) first meter
Portable and small drillingmachine can be utilized
Datasheet:http://www.sisgeo.com/uploads/schede/schede/D2MX_MEXID_EN_01_mexid_miniaturized_extensometer.pdf
![Page 17: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/17.jpg)
BOREHOLE EXTENSOMETERS:MEXID SOLUTION
MODERN SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015
Required drill hole for MEXID:Ø 50 mm (2"), Ø 75 mm (3”) first meter
Portable and small drilling machinecan be utilized
ENGURI DAM ‐ Georgia
![Page 18: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/18.jpg)
ENGURI DAM – Georgia – 2° highest arch dam in the World
![Page 19: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/19.jpg)
MEXID Vs MPBX
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 20: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/20.jpg)
MEXID Vs MPBX
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 21: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/21.jpg)
xy
z
Extenso‐inclinometer columnin dam body and foundation 3D measurement
DEX-S 3-D EXTENSO-INCLINOMETERS
Kárahnjúkar Hydropower Project
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 22: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/22.jpg)
DEX-S 3-D EXTENSO-INCLINOMETERS:APPLICATION IN MEMBRANE EMBANKMENT DAMS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 23: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/23.jpg)
DEX-S 3-D EXTENSO-INCLINOMETERS:APPLICATION IN ZONED EMBANKMENT DAMS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 24: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/24.jpg)
DEX-S: MAIN COMPONENTS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
DEX‐S in‐place extenso‐inclinometerprobe
Bottom borehole anchorSupport headCasing with
magnet ring
Datasheet:http://www.sisgeo.com/uploads/schede/schede/dex_en.pdf
![Page 25: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/25.jpg)
DEX-S: INSTALLATION METHODS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
DEX‐S chainwith upper reference(hanging fromthe top)
DEX‐S chainwith lowerreference(stiff chainconnected to the bottom anchor)
DEX‐S probes
Casing
![Page 26: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/26.jpg)
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
DEX-S INSTALLATION:SUSPENDED FROM THE TOP
Suspending steel cable
DEX or DEX‐S probe
Top cap
Magnet ring
![Page 27: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/27.jpg)
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
DEX-S INSTALLATION:BOTTOM ANCHOR
DEX or DEX‐S probe
Steel placing rod
Bottom anchor reference
Magnet ring
![Page 28: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/28.jpg)
BH PROFILE INCLINOMETERS:APPLICATION AND AIM
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
BH Profile inclinometers can be installed in:
• dam body
• dam upstream face
• dam abutments
![Page 29: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/29.jpg)
BH PROFILE INCLINOMETERS:APPLICATION IN MEMBRANE EMBANKMENT DAMS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 30: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/30.jpg)
BH PROFILE INCLINOMETERS:APPLICATION IN ZONED EMBANKMENT DAMS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 31: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/31.jpg)
BH PROFILE INCLINOMETERS: COMPONENTS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
Inclinometer sensor(digital MEMS)
Carbon fiberextension rod
Datasheet:http://www.sisgeo.com/uploads/schede/schede/S430_EN‐00_BH_profile_inclinometer.pdf
![Page 32: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/32.jpg)
BH PROFILE INCLINOMETERS:CONTINUOUS BOREHOLE PROFILING
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 33: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/33.jpg)
BH PROFILE INCLINOMETERS: DATALOGGER CONNECTION
Connection of up to 250 BH Profileinclinometers to datalogger withonly one single signal cable (RS485 technology)
![Page 34: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/34.jpg)
OMNIALOG DATALOGGER AND DATA ACQUISITION SYSTEMS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 35: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/35.jpg)
OMNIALOG DATALOGGER
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015
Display
Keyboard
Standard LAN port
USB port
On‐board channels
Alarm output
![Page 36: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/36.jpg)
OMNIALOG DATALOGGER PERFORMANCE
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015
ACCURACY 0.01% FS, 24‐bit A/D
TEMP. RANGE ‐30° .. +70°(constant performances all over the range)
SAMPLING RATE high.. medium.. Low
ON BOARD CHANN. 8 (differential)
TOTAL CHANNELS up to 391 analogue ch. up to 254 digital ch.
Datasheet:http://www.sisgeo.com/uploads/schede/schede/OMNIALOG_EN_01_‐_OMNIAlog_Datalogger.pdf
![Page 37: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/37.jpg)
OMNIALOG DATA ACQUISITION SYSTEMS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
Stainless steel cabinet
Multiplexer expansion boards
Communication interface
Digital instrument input
External multiplexer input
Back up battery
Datasheet:http://www.sisgeo.com/uploads/schede/schede/OMNIA_DAS_EN_00_data_acquisition_system.pdf
![Page 38: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/38.jpg)
OMNIALOG DAS - THETA DAM, KENYA
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 39: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/39.jpg)
OMNIALOG SYSTEMS: NO SOFTWARE NEEDED
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
• Independent OS platform
• No software installation is required
HTML
![Page 40: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/40.jpg)
OMNIALOG SYSTEMS: WEB SERVER ON BOARD
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 41: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/41.jpg)
OMNIALOG SYSTEMS: WEB SERVER ON BOARD
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
![Page 42: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/42.jpg)
OMNIALOG SYSTEMS: WEB SERVER ON BOARD
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015
![Page 43: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/43.jpg)
OMNIALOG DAS: EXTERNAL MULTIPLEXERS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015
FASE 1:Instruments are wired to the external mux working as temporary stand‐alone junction boxes. New Leonardo portable readout can read and store data of all the connected instruments simply clicking a button.
![Page 44: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/44.jpg)
OMNIALOG DAS: EXTERNAL MULTIPLEXERS
CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING
FASE 2:Multiplexer boxes are connected to OMNIAlogcabinet in order to automatically manage all the instruments wired to the MUX boxes.
![Page 45: Clever solutions for dam safety and monitoring - ENG ... · CLEVER SOLUTIONS FOR DAM SAFETY AND MONITORING – TEHERAN 15/10/2015 FASE 1: Instruments are wired to the external muxworking](https://reader031.fdocuments.us/reader031/viewer/2022040214/5eb55a4ac9e2ba098f065b04/html5/thumbnails/45.jpg)
GIANFRANCO IANNACCONEGerente Latinoamé[email protected]óvil Col: +57 318‐2001544Móvil Ita: +39 346‐1365229Tel: +57 1 6368710