Clearwater Treatment · PDF fileEVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS –...
Transcript of Clearwater Treatment · PDF fileEVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS –...
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected] .com
AUSTRALIAN WATER ASSOCIATION MEMBER
water Treatment Industries
Dear
Thank you for your enquiry concerning the 10 Person Aqua-Nova Treatment System approved by the N.S.W. Department of Health, which carries Quality Assurance certification.
This AQUA-NOVA system comes with the following, which is all-inclusive in the price set out below:
1 only 3,000-litre POLYMER baffled septic tank Australian Standards Approved 1 only 3,000-litre POLYMER Sewage Treatment System (NSW Health Approved AWTS 006)
TOTAL OPERATING CAPACITY = 6,000 LITRES TOTAL HOLDING CAPACITY = 9,000 LITRES EMERENCY STORAGE UP TO = 2,000 LITRES
We also supply the following inclusive of the price set out below:
All inter-connecting pipe work between these two tanks 100 M
2 irrigation package including 50 metres of 25mm poly pipe
with 5 sprinklers and a pressure relief non-return valve for your convenience Audio/Visual Alarm system DELIVERY TO SITE AND COMMISSIONING
SERVICING Your first 12 months of servicing is included in the purchase price of your wastewater system which includes commissioning of system plus 3 services to be conducted on a quarterly basis. Once your last FREE (4
th) service has been conducted, we will automatically issue you with a service contract
for the next 12 monthly period. (Please ask for more details) Please note the above quotation DOES NOT include the following:
* Septic tank application fee * Any electrical * Any excavation
CHOICE OF 3 DIFFERENT TANK INVERT MODELS 425MM * 750MM * 870MM
COST (Including GST) 425MM $ PAYMENT TERMS ARE C.O.D.
WARRANTY Tank 25 Years *
Electrical components 2 Years * Other components 5 Years *
Yours truly,
BERNARD NEYLAN DIRECTOR
Design, Manufacture & Distribution Of Sewage Treatment Systems For Domestic & Commercial
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected] .com
AUSTRALIAN WATER ASSOCIATION MEMBER
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected] .com
AUSTRALIAN WATER ASSOCIATION MEMBER
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected] .com
AUSTRALIAN WATER ASSOCIATION MEMBER
Aqua-Nova Everhard Industries An Australian Success Story Since 1926 For over 75 years the name Everhard has been at the forefront of experience, service and quality in the manufacture of innovative products designed to provide efficient solutions in the management and treatment of Wastewater. As of 31 October 1999, all wastewater treatment systems in NSW must be accredited under the new and revised NSW Health Department Aerated Wastewater Treatment Systems Accreditation Guideline 1998 to receive council approval for installation. The Aqua Nova system is accredited under these new NSW Health Department guidelines (approval numbers: Concrete System – C of A AWTS 004, Polymer System – C of A AWTS 006.) It has undergone a rigorous testing program and meets the specified performance criteria in all categories. You can be confident that water treated using the Aqua Nova is clean, odourless and safe. All sales inquiries will be handled by trained and experienced operators – In their words the customer talks to the person who is responsible for installing, commissing and servicing the unit – We will not use high pressure, untrained, commission sales people. Everhard Industries stands behind our approved distributors, and backs up all warranties and the performance of the unit. We believe this offers the convenience and peace of mind in dealing with local installers backed by the strength and technical know-how of Everhard Industries.
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected] .com
AUSTRALIAN WATER ASSOCIATION MEMBER
water Treatment Industries
DAILY POWER CONSUMPTION
AQUA-NOVA 2000 SEWAGE TREATMENT SYSTEM
An Aqua-Nova 2000 sewage treatment system was tested at the residence of Mrs Manning at Currawarna, N.S.W in September 2000. TESTING CRITERIA Energy was metered through a Great Southern Energy supply authority kilowatt-hour meter. IRRIGATION PUMP –HYDRAULIC LOADINGS – Town water supply only
2 Adults & 2 children being of a minimum age of 12 years Irrigation Requirements
1. Submersible Pump servicing 5 sprays on 450mm risers attached to 50 metres of 25mm poly pipe on level ground
2. Irrigation pump size a 10-metre head submersible type. Flow 4 normal loads of washing
4 separate showers per day The dishwasher was put thru a normal daily wash cycle
AERATION PUMP
NITTO Aeration pump Model LA-80 that ran continuously for 24 hours in the above Aqua-Nova treatment system, which has been commissioned. RESULTS
AERATION PUMP used 1.2 kilowatts of electricity IRRIGATION PUMP used 0.85 kilowatts of electricity. TOTAL ELECTRICITY USED = 2.05 Kilowatt x $0.12 cents per kilowatt hour Under the above criteria this system costs 25 cents PER DAY. This case study was conducted in conjunction with Clearwater Industries and Great Southern Energy. BERNARD NEYLAN
DIRECTOR
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected] .com
AUSTRALIAN WATER ASSOCIATION MEMBER
water Treatment Industries
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected] .com
AUSTRALIAN WATER ASSOCIATION MEMBER
water Treatment Industries
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected]
AUSTRALIAN WATER ASSOCIATION MEMBER
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected]
AUSTRALIAN WATER ASSOCIATION MEMBER
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected]
AUSTRALIAN WATER ASSOCIATION MEMBER
water Treatment Industries
ELECTRICAL INSTRUCTIONS
All electrical work must be by an appropriately licensed tradesman in accordance with AS3000, and any local
regulatory Authority conditions.
The AWTS units must be protected by a dedicated 16-amp 8kV circuit breaker. This device must not be
installed in the Earth Leakage Loop.
Only a single supply line from the controlling switchboard to the AWTS Tank-Top Control Box is required. The
minimum cable size is 2.5mm diameter for each of the three wires, Active, Neutral and Earth. The cable from the
controlling switchboard to the AWTS Tank should be housed in a suitable protective conduit for its entire length,
and buried to a safe depth. The cable location should be noted and marked on the site layout drawings, and a
copy supplied to the householder.
A section of flexible conduit must be used where the cable emerges from the ground beside the tank,
with a loop of cable to allow for ground settlement.
The Tank-Top Control Box is fitted with an
external Alarm Plate to warn of system failure through
loss of electrical power to the air compressor and
irrigation pump. This will NOT be activated by a general
loss of power to air compressor and the irrigation pump.
This will NOT be activated by a general loss of power to
the whole installation. No other alarm will be supplied
unless specified.
Internal
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected]
AUSTRALIAN WATER ASSOCIATION MEMBER
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected]
AUSTRALIAN WATER ASSOCIATION MEMBER
water Treatment Industries
LISTED BELOW IS A PARTIAL LIST OF REFERENCES & ACKNOWLEDGEMENTS IN BOTH DOMESTIC AND COMMERICAL SEWAGE TREATMENT
EPA (Vic) Approval No CA 040/94
Bargo Caravan Park – 15,000 litres per day
Dept of Defence – Kapooka Army Base – 9,000 litres per day
Riverina Anglican College – 3,000 litres per day
Environmental Australia Building
Australian Greenhouse Office
Transgrid
Australian Federal Police
Dog on the Tuckerbox Tourist Facility
Totalcare (ACT)
Civil & Civic
Project CO Ordination
Tyco Group
Caltex Australia
Hughes Trueman Pty Ltd
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected]
AUSTRALIAN WATER ASSOCIATION MEMBER
DATE REVISION By CLEARWATER TREATMENT INDUSTRIES PTY. LTD.
A.C.N. 07644671 17/12/97 Updated RP
SEPTIC TANK
INFORMATION SHEET No.1
DRAWN CHECKED SCALE DRAWING No.
B.N. STI
25/1/97
EVERHARD INDUSTIRES PTY LTD – AMAZING 80 YEARS – THE INNOVATION CONTINUES
Major Distribution Centre Tel (02) 6925 8799
Sydney Wagga Wagga Griffith Queanbeyan Fax (02) 6925 8588 (PO Box 1160) 111 Biroomba Lane Mobile 0429 651 116 Wagga Wagga NSW 2650 Email [email protected]
AUSTRALIAN WATER ASSOCIATION MEMBER
water Treatment Industries
The statements below are known to be true and can be verified by the NSW Health Dept despite claims by some manufacturers in an effort to make quick sales. If you require wastewater-recycling system phone someone who will be here for the long term. The Aqua-Nova system has a factory backing of Everhard Industries 80 year old Australian company with an 80 year old good reputation.
FACT – All modern systems, no matter what make or brand name, use naturally occurring bacteria to break down and digest waste as a food form. These helpful bacteria when given ideal conditions inside the treatment system will multiply and convert harmful waste products into clean garden irrigation water.
FACT – Despite the claims of some manufacturers it is extremely inadvisable to dispose of harsh antibacterial cleaners such as bleaches and other chlorine based products as well as strong disinfectants into either septic tanks or treatment systems. These household chemicals cannot differentiate between harmful and helpful bacteria and destroy them all. This is greatly affects the processing of wastewater in all treatment systems. A fact easily verified by your local council health officer.
FACT – The household use of biodegradable and environmentally friendly cleaners that are low on sodium and phosphorous will reduce the build up of these harmful elements in the soils around your home.
FACT – All treatment systems require that the water loads from your home spend a given time within the treatment system in order for the treatment process to work. Common sense really! If your washing machine processes and discharges multiple loads, then a huge load of wastewater can prove too much in a short time for the helpful bacteria to properly treat. SIMPLE SOLUTION: Spread your washing loads over several days. *FICTION* - Household treatment systems never need desludging
FACT – All waste contains some non-organic components and while it is true that aerobic bacteria do digest a large range of waste, eventually an undigested sludge layer will occur. (Ask the owner of a system 7-8 years old) *FICTON* - Homeowners can discharge the treated water anywhere through sprinklers
FACT – If there were a system malfunction or power failure this discharge could be a health risk, so most Council Health Depts require dripper discharge to your garden, either below soil or a mulch layer. Each Council has its own regulations so give them a call.
We are a licensed Everhard approved Local Aqua nova agent with code compliance. Licence No 15047