Clariion Disk Format
Disk Format
The Clariion Formats the disks in Blocks. Each Block written out
to the disk is 520 bytes in size. Of the 520 bytes, 512 bytes is
used to store the actual DATA written to the block. The remaining
8 bytes per block is used by the Clariion to store System
Information, such as a Timestamp, Parity Information, Checksum
Data.
Element Size – The Element Size of a disk is determined when a
LUN is bound to the RAID Group. In previous versions of
Navisphere, a user could configure the Element Size from 4
blocks per disk 256 blocks per disk. Now, the default Element
Size in Navisphere is 128. This means that the Clariion will write
128 blocks of data to one physical disk in the RAID Group before
moving to the next disk in the RAID Group and write another 128
blocks to that disk, so on and so on.
Chunk Size – The Chunk Size is the amount of Data the Clariion
writes to a physical disk at a time. The Chunk Size is calculated
by multiplying the Element Size by the amount of Data per block
written by the Clariion.
128 blocks x 512 bytes of Data per block = 65,536 bytes of Data
per Disk. That is equal to 64 KB. So, the Chunk Size, the amount
of Data the Clariion writes to a single disk, before writing to the
next disk in the RAID Group is 64 KB.Posted by san guy at 11:42 AM 5 comments
LUNs
on blogs: January 2008 http://clariionblogs.blogspot.com/2008_01_01_arc
12/8/2011
8/3/2019 Clariion Blogs_ January 2008 LUN's
http://slidepdf.com/reader/full/clariion-blogs-january-2008-luns 2/8
LUNs
As stated in the Host Configuration Slide, a LUN is the disk space
that is created on the Clariion. The LUN is the space that is
presented to the host. The host will see the LUN as a “Local Disk.”
In Windows, the Clariion LUN wil l show up in Disk Manager is
Drive #, which the Windows Administrator can now format,
partition, assign a Drive Letter, etc…
In UNIX, the Clariion LUN will show up as a c_t_d_ address,
which the UNIX Administrator can now mount.
A LUN is owned by a single Storage Processor at a time. When
creating a LUN, you assign the LUN to a Storage Processor, SPA,
SPB or let the Clariion choose by selecting AUTO. The Auto option
lets the Clariion assign the next LUN to the Storage Processor
with the fewest number of LUNs.
The Properties/Settings of LUN during creation/binding are:
1. Selecting which RAID Group the LUN will be bound to.
2. If it is the first LUN created on a RAID Group, the first LUN will
set the RAID Type for the entire RAID Group. Therefore, when
creating/binding the first LUN on a RAID Group, you can selectthe RAID Type.
3. Select a LUN Id or number for the LUN.
4. Specify a REBUILD PRIORITY for the LUN in the event of a Hot
Spare replacing a failed disk.
5. Specify a VERIFY PRIORITY for the LUN to determine the speed
in which the Clariion runs a “SNIFFER” in the background to
scrub the disks.
6. Enable or Disable Read and Write Cache at the LUN level. An
example might be to disable Read/Write Cache for a LUN that is
given to a Development Server. This ensures that the
Development LUNs will not use the Cache that is needed for
Production Data.
7. Enable Auto Assign. By default this box is unchecked in
Navisphere. That is because you will have some sort of Host
Based Software that will manage the trespassing and failing back
of a LUN.
8. Number of LUNs to Bind. You can bind up to 128 LUNs on a
single RAID Group.
9. SP Ownership. You can select if you want your LUN(s) to
belong to SP A, SP B, or the AUTO option in which the Clariion
decides LUN ownership based on the Storage Processor with the
fewest number of LUNs.
10. LUN Size. You specify the size of a LUN by entering the
numbers and selectin MB Me aB tes GB Gi aB tes TB
on blogs: January 2008 http://clariionblogs.blogspot.com/2008_01_01_arc
12/8/2011
8/3/2019 Clariion Blogs_ January 2008 LUN's
http://slidepdf.com/reader/full/clariion-blogs-january-2008-luns 3/8
(TeraBytes), or Block Count to specify the number of blocks a
LUN will be. This is critical for SnapView Clones, and MirrorView
Secondary LUNs.
The amount of LUNs a Clariion can support is going to be Clariion
specific.
CX 300 – 512 LUNs
CX3-20 – 1024 LUNs
CX3-80 – 2048 LUNs
Posted by san guy at 11:33 AM 2 comments
Tuesday, January 29, 2008
RAID 1_0
Order of Disks in RAID Group for RAID 1_0.
When creating a RAID 1_0 Raid Group, it is important to know
and understand the order of the drives as they are put into the
RAID Group will absolutely make a difference in the Performance
and Protection of that RAID Group. If left to the Clariion, it will
simply choose the next disks in the order in which is sees the
disks to create the RAID Group. However, this may not be the
best way to configure a RAID 1_0 RAID Group. Navisphere will
take the next disks available, which are usually right next to one
another in the same enclosure.
In a RAID 1_0 Group, we want the RAID Group to span multipleenclosures as illustrated above. The reason for this is as we can
see, the Data Disks will be on Bus 1_Enclosure 0, and the
Mirrored Data Disks will be on Bus 2_Enclosure 0. The advantage
of creating the RAID Group this way is that we place the Data and
Mirrors on two separate enclosures. In the event of an enclosure
failure, the other enclosure could still be alive and maintaining
access to the data or the mirrored data. The second advantage is
Performance. Performance could be gained through this
configuration because you are spreading the workload of the
application across two different buses on the back of the Clariion.
on blogs: January 2008 http://clariionblogs.blogspot.com/2008_01_01_arc
12/8/2011
8/3/2019 Clariion Blogs_ January 2008 LUN's
http://slidepdf.com/reader/full/clariion-blogs-january-2008-luns 4/8
_
Group. In order to for the disks to be entered into the RAID
Group in this order, they must be manually entered into the RAID
Group this way via Navisphere or the Command Line.
The first disk into the RAID Group receives Data Block 1.
The second disk into the RAID Group receives the Mirror of Data
Block 1.
The third disk into the RAID Group receives Data Block 2.
The fourth disk into the RAID Group receives the Mirror of DataBlock 2.
The fifth disk into the RAID Group received Data Block 3.
The sixth disk into the RAID Group receives the Mirror of Data
Block 3.
If we let the Clariion choose these disks in its particular order, it
would select them:
First disk – 1_0_0 (Data Block 1)
Second disk – 1_0_1 (Mirror of Data Block 1)
Third disk – 1_0_2 (Data Block 2)
Fourth disk – 2_0_0 (Mirror of Data Block 2)
Fifth disk – 2_0_1 (Data Block 3)
Sixth disk – 2_0_2 (Mirror of Data Block 3)
This defeats the purpose of having the Mirrored Data on a
different enclosure than the Data Disks.
Posted by san guy at 1:49 PM 11 comments
RAID Groups and Types
RAID GROUPS and RAID Types
The above slide illustrates the concept of creating a RAID Group
and the supported RAID types of the Clariions.
RAID Groups
The concept of a RAID Group on a Clariion is to group together a
number of disks on the Clariion into one big group. Let’s say that
we need a 1 TB LUN. The disks we have a 200 GB in size. We
on blogs: January 2008 http://clariionblogs.blogspot.com/2008_01_01_arc
12/8/2011
8/3/2019 Clariion Blogs_ January 2008 LUN's
http://slidepdf.com/reader/full/clariion-blogs-january-2008-luns 5/8
would have to group together five (5) disks to get to the 1 TB
size needed for the LUN. I know we haven’t taken into account
for parity and what the RAW capacity of a drive is, but that is just
a very basic idea of what we mean by a RAID Group. RAID
Groups also allow you to configure the Clariion in a way so that
you will know what LUNs, Applications, etc…live on what set of
disks in the back of the Clariion. For instance, you wouldn’t want
an Oracle Database LUN on the same RAID Group (Disks) as a
SQL Database running on the same Clariion. This allows you to
create a RAID Group of a # of disks for the Oracle Database, and
another RAID Group of a different set of disks for the SQL
Database.
RAID Types
Above are the supported RAID types of the Clariion.
RAID 0 – Striping Data with NO Data Protection. The
Clariions Cache will write the data out to disk in blocks (chunks)
that we will discuss later. For RAID 0, the Clari ion writes/stripes
the data across all of the disks in the RAID Group. This is
fantastic for performance, but if one of the disks fail in the RAID
0 Group, then the data will be lost because there is no protectionof that data (i.e. mirroring, parity).
RAID 1 – Mirroring. The Clariion will write the Data out to the
first disk in the RAID Group, and write the exact data to another
disk in that RAID 1 Group. This is great in terms of data
protection because if you were to lose the data disk, the mirror
would have the exact copy of the data disk, allowing the user to
access the disk.
RAID 1_0 – Mirroring and Striping Data. This is the best of
both worlds if set up properly. This type of RAID Group will allow
the Clariion to stripe data and mirror the data onto other disks.However, the illustration above of RAID 1_0, is not the best way
of configuring that type of RAID Group. The next slide will go into
detail as to why this isn’t the best method of configuring RAID
1_0.
RAID 3 – Striping Data with a Dedicated Parity Drive. This
type of RAID Group allows the Clariion to stripe data the first X
number of disks in the RAID Group, and dedicate the last disk in
the RAID Group for Parity of the data stripe. In the event of a
single drive failure in this RAID Group, the failed disk can be
rebuilt from the remaining disks in the RAID Group.
RAID 5 – Striping Data with Distributed Parity . RAID type 5
allows the Clariion to distribute the Parity information to rebuild
a failed disk across the disks that make up the RAID Group. As in
RAID 3, in the event of a single drive failure in this RAID Group,
the failed disk can be rebuilt from the remaining disks in the
RAID Group.
RAID 6 – Striping Data with Double Parity . This is new to
Clariion world starting in Flare Code 26 of Navisphere. The
simplest explanation of RAID 6 we can use for RAID 6 is the RAID
Group uses striping, such as RAID 5, with double the parity. This
on blogs: January 2008 http://clariionblogs.blogspot.com/2008_01_01_arc
12/8/2011
8/3/2019 Clariion Blogs_ January 2008 LUN's
http://slidepdf.com/reader/full/clariion-blogs-january-2008-luns 6/8
allows a RAID 6 RAID Group to be able to have two drive failures
in the RAID Group, while maintaining access to the LUNs.
HOT SPARE – A Dedicated Single Disk that Acts as a Failed
Disk . A Hot Spare is created as a single disk RAID Group, and is
bound/created as a HOT SPARE in Navisphere. The purpose of
this disk is to act as the failed disk in the event of a drive failure.
Once a disk is set as a HOT SPARE, it is always a HOT SPARE,
even after the failed disk is replaced. In the slide above, we list
the steps of a HOT SPARE taking over in the event of a disk
failure in the Clariion.
1. A disk fails – a disk fails in a RAID Group somewhere in the
back of the Clariion.
2. Hot Spare is Invoked – a Clariion dedicated HOT SPARE acts as
the failed disk in Navisphere. It will assume the identity of the
failed disk’s Bus_Enclosure_Disk Address.
3. Data is REBUILT Completely onto the Hot Spare from the other
disks in the RAID Group – The Clariion begins to recalculate and
rebuild the failed disk onto the Hot Spare from the other disks in
the RAID Group, whether it be copying from the MIRRORed copyof the disk, or through parity and data calculations of a RAID 3 or
RAID 5 Group.
4. Disk is replaced – Somewhere throughout the process, the
failed drive is replaced.
5. Data is Copied back to new disk – The data is then copied back
to the new disk that was replaced. This will take place
automatically, and will not begin until the failed disk is
completely rebuilt onto the Hot Spare.
6. Hot Spare is back to a Hot Spare – Once the data is written
from the Hot Spare back to the failed disk, the Hot Spare goes
back to being a Hot Spare waiting for another disk failure.
Hot Spares are going to be size and drive type specific.
Size. The Hot Spare must be at least the same size as the largest
size disk in the Clariion. A Hot Spare will replace a drive that is
the same size or a smaller size drive. The Clariion does not allow
multiple smaller Hot Spares replace a failed disk.
Drive Type Specific . If your Clariion has a mixture of Drive
Types, such as Fibre and S.ATA disks, you will need Hot Spares of
those particular Drive Types. A Fibre Hot Spare will not replace afailed S.ATA disk and vice versa.
Hot Spares are not assigned to any particular RAID Group. They
are used by the Clariion in the event of any failure of that Drive
Type. The recommendation for Hot Spares is one (1) Hot Spare
for every thirty (30) disks.
There are multiple ways to create a RAID Group. One is via the
Navisphere GUI, and the other is through the Command Line
Interface. In later slides we will l ist the commands to create a
RAID Group.
on blogs: January 2008 http://clariionblogs.blogspot.com/2008_01_01_arc
12/8/2011
8/3/2019 Clariion Blogs_ January 2008 LUN's
http://slidepdf.com/reader/full/clariion-blogs-january-2008-luns 7/8
Posted by san guy at 1:42 PM 3 comments
The VAULT Drives
Vault Drives
All Clariions have Vault Drives. They are the first five (5) disks in
all Clariions. Disks 0_0_0 through 0_0_4. The Vault drives on the
Clariion are going to contain some internal information that is
pre-configured before you start putting data on the Clariion. The
diagram will show what information is stored on the Vault Disks.
The Vault.
The vault is a ‘save area’ across the first five disks to store write
cache from the Storage Processors in the event of a Power
Failure to the Clariion, or a Storage Processor Failure. The goal
here is to place write cache on disk before the Clari ion powers
off, therefore ensuring that you don’t lose the data that was
committed to the Clariion and acknowledged to the host. The
Clariions have the Standby Power Supplies that will keep the
Storage Processors running as well as the first enclosure of disks
in the event of a power failure. If there is a Storage Processor
Failure, the Clariion will go into a ‘panic’ mode and fear that it
may lose the other Storage Processor. To ensure that it does not
lose write cache data, the Clariion will also dump write cache to
the Vault Drives.
The PSM Lun.
The Persistent Storage Manager Lun stores the configuration of the Clari ion. Such as Disks, Raid Groups, Luns, Access Logix
information, SnapView configuration, MirrorView and SanCopy
configuration as well. When this LUN was first introduced on the
Clariions back on the FC4700s, it used to appear in Navisphere
under the Unowned Luns container as Lun 223-PSM Lun. Users
have not been able to see it in Navisphere for awhile. However,
you can grab the information of the Array’s Configuration by
executing the following command.
naviseccli -h 10.127.35.42 arrayconfig -capture -output
c:\arrayconfig.xml -format XML -schema clariion
on blogs: January 2008 http://clariionblogs.blogspot.com/2008_01_01_arc
12/8/2011
8/3/2019 Clariion Blogs_ January 2008 LUN's
http://slidepdf.com/reader/full/clariion-blogs-january-2008-luns 8/8
Example of Information retrieved from the File:
For a Disk:
/CLAR:Disk
CLAR:Disk type="Category"
CLAR:Bus type="Property"1/CLAR:Bus
CLAR:Enclosure type="Property"0/CLAR:Enclosure
CLAR:Slot type="Property"12/CLAR:Slot CLAR:State type="Property"3/CLAR:State
CLAR:UserCapacityInBlocks
type="Property"274845/CLAR:UserCapacityInBlocks
For a LUN:
/CLAR:LUN
CLAR:LUN type="Category"
CLAR:Name type="Property"LUN 23/CLAR:Name
CLAR:WWN
type="Property"60:06:01:60:06:C4:1F:00:B1:51:C4:1B:B3:A2:
DC:11/CLAR:WWN
CLAR:Number type="Property"6142/CLAR:Number
CLAR:RAIDType type="Property"1/CLAR:RAIDType
CLAR:RAIDGroupID type="Property"13/CLAR:RAIDGroupID
CLAR:State type="Property"Bound/CLAR:State
CLAR:CurrentOwner type="Property"1/CLAR:CurrentOwner
CLAR:DefaultOwner type="Property”2/CLAR:DefaultOwner
CLAR:Capacity type="Property"2097152/CLAR:Capacity
Flare Database LUN.
The Flare Database LUN will contain the Flare Code that is
running on the Clariion. I like to say that it is the application thatruns on the Storage Processors that allows the SPs to create the
Raid Groups, Bind the LUNs, setup Access Logix, SnapView,
MirrorView, SanCopy, etc…
Operating System.
The Operating System of the Storage Processors is stored to the
first five drives of the Clariion.
Now, please understand that this information is NOT in any way
shape or form laid out this way across these disks. We are only
seeing that this information is built onto these first five drives of
the Clariion. This information does take up disk space as well.
The amount of disk space that it takes up per drive is going to
depend on what Flare Code the Clariion is running. Clariions
running Flare Code 19 and lower, will lose approximately 6 GB of
space per disk. Clariions running Flare Code 24 and up, will lose
approximately 33 GB of space per disk. So, on a 300 GB fibre
drive, the actual raw capacity of the drive is 268.4 GB. Also, you
would subtract another 33 GB per disk for this Vault/PSM
LUN/Flare Database LUN/Operating System Information. That
would leave you with about 235 GB per disk on the first five
disks.
on blogs: January 2008 http://clariionblogs.blogspot.com/2008_01_01_arc