Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. ·...

12
LONG-TERM CENTRAL VENOUS CATHETERS Choose from our comprehensive line of long-term central venous catheters. Cook Spectrum ® Hyperalimentation Catheter Set Cook TPN Catheter Set Cook TPN REDO Catheter Set Cook TPN Catheter Repair Set

Transcript of Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. ·...

Page 1: Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. · Cook TPN REDO Catheter Set Cook TPN catheters can be tunnelled subcutaneously and are

LONG-TERM CENTRAL VENOUS CATHETERS

Choose from our comprehensive line of long-term central venous catheters.

Cook Spectrum® Hyperalimentation Catheter Set

Cook TPN™ Catheter Set

Cook TPN REDO Catheter Set

Cook TPN Catheter Repair Set

Page 2: Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. · Cook TPN REDO Catheter Set Cook TPN catheters can be tunnelled subcutaneously and are

1. Raad I, Darouiche R, Dupuis J, et al. Central venous catheters coated with minocycline and rifampin for the preven-tion of catheter-related colonization and bloodstream infections: a randomized, double-blind trial. Ann Intern Med. 1997;127(4):267-274.

2. Ramos ER, Reitzel R, Jiang Y, et al. Clinical effectiveness and risk of emerging resistance associated with prolonged use of antibiotic-impregnated catheters: more than 0.5 million catheter days and 7 years of clinical experience. Crit Care Med. 2011;39(2):245-251.

3. Zimlichman E, Henderson D, Tamir O, et al. Health care-associated infections: a meta-analysis of costs and financial impact on the US health care system. JAMA Intern Med. 2013;173(22):2039-2046.

4. O’Grady N, Alexander M, Burns L, et al. Guidelines for the prevention of intravascular catheter-related infections, 2011. Centers for Disease Control and Prevention Web site. www.cdc.gov/infectioncontrol/guidelines/pdf/bsi/bsi-guidelines-H.pdf. Updated October 2017. Accessed October 26, 2018. The 1A recommendation from the Centers for Disease Control and Prevention (CDC) guidelines for the prevention of intravascular catheter-related infections, 2011, is to “use a chlorhexidine/silver sulfadiazine or minocycline/rifampin -impregnated CVC in patients whose catheter is expected to remain in place >5 days if, after successful implementation of a comprehensive strategy to reduce rates of CLABSI, the CLABSI rate is not decreasing.”

Provide your patients with proven protection against CRBSIs.1

We developed Cook Spectrum technology to help provide optimal patient care by decreasing hospitals’ rates of catheter-related bloodstream infections (CRBSIs).1

The right combinationCook Spectrum catheters are impregnated with a combination of the antibiotics minocycline and rifampin in order to help patients by providing proven protection against CRBSIs.1

Unmatched evidenceThe efficacy of Cook Spectrum is supported by more than 30 sources published over the past two decades, including peer-reviewed studies and meta-analyses.

No evidence of increased resistanceMore than 10 years of clinical use and a 7-year study of more than 500,000 Cook Spectrum catheter days have shown no evidence of increased antibiotic resistance.2

Worth switchingSwitching from unimpregnated catheters to Cook Spectrum catheters helps provide quality patient care by decreasing the risk for CRBSIs and the costs associated with treating them.1,3

Page 3: Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. · Cook TPN REDO Catheter Set Cook TPN catheters can be tunnelled subcutaneously and are

Learn more about Cook Spectrum technology, including links to a vast body of research investigating and supporting Cook Spectrum, at spectrum.cookmedical.com.

CDC 1ARECOMMENDATION

as a component of the prevention of

CLABSIs.4

CookSPECTRUM CATHETERS

meet the

PROCESS BUNDLESPECTRUMTECHNOLOGY

Page 4: Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. · Cook TPN REDO Catheter Set Cook TPN catheters can be tunnelled subcutaneously and are

Cook Spectrum® Hyperalimentation Catheter Set

Cook Spectrum catheters are impregnated with the antibiotics minocycline and rifampin to prevent CLABSIs and CRBSIs.

These catheters are used for the intravenous administration of nutrient fluids, chemotherapeutic agents, therapeutic drugs, and for blood sampling, blood delivery, and venous pressure monitoring.

Set components

The clearly marked colour-coded hubs allow combination therapies in multilumen catheters.

The soft, flexible silicone catheter material provides optimum patient comfort.

The synthetic fibre cuff is affixed to the catheter in order to allow tissue ingrowth.

The suture wings provide secure fixation.

The orange color indicates that the catheter has Cook Spectrum technology that protects against CLABSIs and CRBSIs.

• Cook Spectrum Hyperalimentation Catheter

• Introducer needle• Wire guide• Peel-Away® sheath and dilator• Disposable syringe• Disposable safety scalpel• Paper measuring tape• Safety sharps receptacle

Page 5: Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. · Cook TPN REDO Catheter Set Cook TPN catheters can be tunnelled subcutaneously and are

Order Number

Reference Part Number

Catheter Fr

Catheter Length

cmIntroducer

Fr

Sheath/DilatorLength

cm

Wire Guide Diameter

inch

Single lumen setG51197 HASC-5.0-ABRM 5 25 5.5 9/13 .018

Double lumen setG51198 HASDC-7.0-LSC-ABRM 7 25 8 9/13 .018

G32401 C-HASD-701J-RSC-CLMP-ABRM* 7 20 8 9/13 .038

G32400 C-HASD-701J-LSC-CLMP-ABRM* 7 25 8 9/13 .038

Triple lumen setG32403 C-HAST-801J-CLMP-ABRM* 8 25 9 9/13 .038

INTRODUCER NEEDLEStainless steel

PEEL-AWAY SHEATH AND DILATORDISPOSABLE

SYRINGE

WIRE GUIDEStainless steel

Cuff

CATHETERSilicone

PROCESS BUNDLESPECTRUMTECHNOLOGY

*The catheter does not have a cuff. Some products or part numbers may not be available in all markets. Contact your local Cook Medical sales representative or Customer Service for details.

Page 6: Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. · Cook TPN REDO Catheter Set Cook TPN catheters can be tunnelled subcutaneously and are

Cook TPN™

Catheter Set

Cook TPN catheters can be tunnelled subcutaneously and are used for the intravenous administration of parenteral nutrition, chemotherapeutic agents, and therapeutic drugs, and for blood sampling and blood delivery.

Set components

The clearly marked colour-coded hubs allow combination therapies in multilumen catheters.

The soft, flexible silicone catheter material is designed for patient comfort.

The synthetic fibre cuff is affixed to the catheter in order to allow tissue ingrowth.

• Cook TPN Catheter• Introducer needle• Wire guide• Peel-Away sheath and dilator• Disposable syringe

Page 7: Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. · Cook TPN REDO Catheter Set Cook TPN catheters can be tunnelled subcutaneously and are

Order Number

Reference Part Number

Catheter Fr

Catheter Length

cmIntroducer

Fr

Sheath/DilatorLength

cm

Wire Guide Diameter

inch

Triple lumen setG03319 C-TPNS-8.0T-90 8 90 9 9/13 .038

Some products or part numbers may not be available in all markets. Contact your local Cook Medical sales representative or Customer Service for details.

SM #1

SM #2

INTRODUCER NEEDLEStainless steel

PEEL-AWAY SHEATH AND DILATOR DISPOSABLE

SYRINGE

WIRE GUIDEStainless steel

Cuff

CATHETERSilicone

Page 8: Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. · Cook TPN REDO Catheter Set Cook TPN catheters can be tunnelled subcutaneously and are

Cook TPN REDO Catheter Set

Cook TPN catheters can be tunnelled subcutaneously and are used for the intravenous administration of parenteral nutrition, chemotherapeutic agents, and therapeutic drugs, and for blood sampling and blood delivery. The “REDO” suffix on the order number indicates that the cuff is 2.5 cm distal to the suture rings.

The synthetic fibre cuff is affixed to the catheter in order

to allow tissue ingrowth.

2.5 cm

The circumferential suturering allows you to securethe catheter to the skin byusing a suture during tissueingrowth into the cuff.

The soft, flexible silicone catheter material is designed

for patient comfort.

Set components

• Cook TPN REDO Catheter• Introducer needle• Wire guide• Peel-Away sheath

and dilator• Disposable syringe

The clearly marked hubs ensure confidence and accuracy when administering therapies and fluids.

Page 9: Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. · Cook TPN REDO Catheter Set Cook TPN catheters can be tunnelled subcutaneously and are

SMALL

CATHETERSilicone

PEEL-AWAY SHEATH AND DILATOR

WIRE GUIDEStainless steel

CuffSuture rings

INTRODUCER NEEDLEStainless steel

Order Number

Reference Part Number

Catheter Fr

Catheter Length

cmIntroducer

Fr

Sheath/DilatorLength

cm

Wire Guide Diameter

inch

Single lumen setG07960 C-TPNS-3.0-65-REDO 3 65 3.5 7/11 .018

G07903 C-TPNS-4.0-65-REDO 4 65 5 7/11 .025

G07933 C-TPNS-6.5-90-REDO 6.5 90 7 9/13 .035

G08132 C-TPNS-9.5-90-REDO 9.5 90 10 9/13 .038

Double lumen setG07935 C-TPNS-5.0D-65-12-REDO 5 65 5.5 9/13 .025

G07902 C-TPNS-7.0D-65-REDO 7 65 8 9/13 .035

G29464 C-TPNS-9.0D-90-REDO 9 90 10 9/13 .038

G08074 C-TPNS-12.0D-90-REDO 12 90 13 9/13 .038

Some products or part numbers may not be available in all markets. Contact your local Cook Medical sales representative or Customer Service for details.

DISPOSABLE SYRINGE

Page 10: Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. · Cook TPN REDO Catheter Set Cook TPN catheters can be tunnelled subcutaneously and are

Cook TPN

Catheter Repair Set

Set components(Double lumen repair set shown)

• Repair catheter assembly• Adhesive• Luer needle stub• Disposable syringe

Used to repair Cook TPN and TPN REDO catheters.

Page 11: Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. · Cook TPN REDO Catheter Set Cook TPN catheters can be tunnelled subcutaneously and are

Order Number

Reference Part Number

Repairs Catheter

Fr

Single lumen setG02120 C-RHCS-3.0 3

G01868 C-RHCS-4.0 4

G01869 C-RHCS-6.5 6.5

G01870 C-RHCS-9.5 9.5

Double lumen setG05498 C-RHCD-5.0 5

G01987 C-RHCD-7.0 7

G02777 C-RHCD-9.0 9

G01977 C-RHCD-12.0 12

Triple lumen setG03538 C-RHCT-8.0 8

Some products or part numbers may not be available in all markets. Contact your local Cook Medical sales representative or Customer Service for details.

ADHESIVE

(Triple lumen repair set shown) LUER NEEDLE STUB

DISPOSABLE SYRINGE

TRIPLE LUMEN REPAIR CATHETER ASSEMBLYSilicone

Page 12: Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. · Cook TPN REDO Catheter Set Cook TPN catheters can be tunnelled subcutaneously and are

Tunneller

Order Number

Reference Part Number

CompatibleFr

G20304 IPA-4001 4-7

G20305 IPA-4002 8-12

Some products or part numbers may not be available in all markets. Contact your local Cook Medical sales representative or Customer Service for details.

TUNNELLER

© COOK 02/2019 CC-D45591-EN-F

M E D I C A L CC, URO-A4