Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. ·...
Transcript of Choose from our comprehensive line of long-term central venous catheters… · 2019. 2. 27. ·...
LONG-TERM CENTRAL VENOUS CATHETERS
Choose from our comprehensive line of long-term central venous catheters.
Cook Spectrum® Hyperalimentation Catheter Set
Cook TPN™ Catheter Set
Cook TPN REDO Catheter Set
Cook TPN Catheter Repair Set
1. Raad I, Darouiche R, Dupuis J, et al. Central venous catheters coated with minocycline and rifampin for the preven-tion of catheter-related colonization and bloodstream infections: a randomized, double-blind trial. Ann Intern Med. 1997;127(4):267-274.
2. Ramos ER, Reitzel R, Jiang Y, et al. Clinical effectiveness and risk of emerging resistance associated with prolonged use of antibiotic-impregnated catheters: more than 0.5 million catheter days and 7 years of clinical experience. Crit Care Med. 2011;39(2):245-251.
3. Zimlichman E, Henderson D, Tamir O, et al. Health care-associated infections: a meta-analysis of costs and financial impact on the US health care system. JAMA Intern Med. 2013;173(22):2039-2046.
4. O’Grady N, Alexander M, Burns L, et al. Guidelines for the prevention of intravascular catheter-related infections, 2011. Centers for Disease Control and Prevention Web site. www.cdc.gov/infectioncontrol/guidelines/pdf/bsi/bsi-guidelines-H.pdf. Updated October 2017. Accessed October 26, 2018. The 1A recommendation from the Centers for Disease Control and Prevention (CDC) guidelines for the prevention of intravascular catheter-related infections, 2011, is to “use a chlorhexidine/silver sulfadiazine or minocycline/rifampin -impregnated CVC in patients whose catheter is expected to remain in place >5 days if, after successful implementation of a comprehensive strategy to reduce rates of CLABSI, the CLABSI rate is not decreasing.”
Provide your patients with proven protection against CRBSIs.1
We developed Cook Spectrum technology to help provide optimal patient care by decreasing hospitals’ rates of catheter-related bloodstream infections (CRBSIs).1
The right combinationCook Spectrum catheters are impregnated with a combination of the antibiotics minocycline and rifampin in order to help patients by providing proven protection against CRBSIs.1
Unmatched evidenceThe efficacy of Cook Spectrum is supported by more than 30 sources published over the past two decades, including peer-reviewed studies and meta-analyses.
No evidence of increased resistanceMore than 10 years of clinical use and a 7-year study of more than 500,000 Cook Spectrum catheter days have shown no evidence of increased antibiotic resistance.2
Worth switchingSwitching from unimpregnated catheters to Cook Spectrum catheters helps provide quality patient care by decreasing the risk for CRBSIs and the costs associated with treating them.1,3
Learn more about Cook Spectrum technology, including links to a vast body of research investigating and supporting Cook Spectrum, at spectrum.cookmedical.com.
CDC 1ARECOMMENDATION
as a component of the prevention of
CLABSIs.4
CookSPECTRUM CATHETERS
meet the
PROCESS BUNDLESPECTRUMTECHNOLOGY
Cook Spectrum® Hyperalimentation Catheter Set
Cook Spectrum catheters are impregnated with the antibiotics minocycline and rifampin to prevent CLABSIs and CRBSIs.
These catheters are used for the intravenous administration of nutrient fluids, chemotherapeutic agents, therapeutic drugs, and for blood sampling, blood delivery, and venous pressure monitoring.
Set components
The clearly marked colour-coded hubs allow combination therapies in multilumen catheters.
The soft, flexible silicone catheter material provides optimum patient comfort.
The synthetic fibre cuff is affixed to the catheter in order to allow tissue ingrowth.
The suture wings provide secure fixation.
The orange color indicates that the catheter has Cook Spectrum technology that protects against CLABSIs and CRBSIs.
• Cook Spectrum Hyperalimentation Catheter
• Introducer needle• Wire guide• Peel-Away® sheath and dilator• Disposable syringe• Disposable safety scalpel• Paper measuring tape• Safety sharps receptacle
Order Number
Reference Part Number
Catheter Fr
Catheter Length
cmIntroducer
Fr
Sheath/DilatorLength
cm
Wire Guide Diameter
inch
Single lumen setG51197 HASC-5.0-ABRM 5 25 5.5 9/13 .018
Double lumen setG51198 HASDC-7.0-LSC-ABRM 7 25 8 9/13 .018
G32401 C-HASD-701J-RSC-CLMP-ABRM* 7 20 8 9/13 .038
G32400 C-HASD-701J-LSC-CLMP-ABRM* 7 25 8 9/13 .038
Triple lumen setG32403 C-HAST-801J-CLMP-ABRM* 8 25 9 9/13 .038
INTRODUCER NEEDLEStainless steel
PEEL-AWAY SHEATH AND DILATORDISPOSABLE
SYRINGE
WIRE GUIDEStainless steel
Cuff
CATHETERSilicone
PROCESS BUNDLESPECTRUMTECHNOLOGY
*The catheter does not have a cuff. Some products or part numbers may not be available in all markets. Contact your local Cook Medical sales representative or Customer Service for details.
Cook TPN™
Catheter Set
Cook TPN catheters can be tunnelled subcutaneously and are used for the intravenous administration of parenteral nutrition, chemotherapeutic agents, and therapeutic drugs, and for blood sampling and blood delivery.
Set components
The clearly marked colour-coded hubs allow combination therapies in multilumen catheters.
The soft, flexible silicone catheter material is designed for patient comfort.
The synthetic fibre cuff is affixed to the catheter in order to allow tissue ingrowth.
• Cook TPN Catheter• Introducer needle• Wire guide• Peel-Away sheath and dilator• Disposable syringe
Order Number
Reference Part Number
Catheter Fr
Catheter Length
cmIntroducer
Fr
Sheath/DilatorLength
cm
Wire Guide Diameter
inch
Triple lumen setG03319 C-TPNS-8.0T-90 8 90 9 9/13 .038
Some products or part numbers may not be available in all markets. Contact your local Cook Medical sales representative or Customer Service for details.
SM #1
SM #2
INTRODUCER NEEDLEStainless steel
PEEL-AWAY SHEATH AND DILATOR DISPOSABLE
SYRINGE
WIRE GUIDEStainless steel
Cuff
CATHETERSilicone
Cook TPN REDO Catheter Set
Cook TPN catheters can be tunnelled subcutaneously and are used for the intravenous administration of parenteral nutrition, chemotherapeutic agents, and therapeutic drugs, and for blood sampling and blood delivery. The “REDO” suffix on the order number indicates that the cuff is 2.5 cm distal to the suture rings.
The synthetic fibre cuff is affixed to the catheter in order
to allow tissue ingrowth.
2.5 cm
The circumferential suturering allows you to securethe catheter to the skin byusing a suture during tissueingrowth into the cuff.
The soft, flexible silicone catheter material is designed
for patient comfort.
Set components
• Cook TPN REDO Catheter• Introducer needle• Wire guide• Peel-Away sheath
and dilator• Disposable syringe
The clearly marked hubs ensure confidence and accuracy when administering therapies and fluids.
SMALL
CATHETERSilicone
PEEL-AWAY SHEATH AND DILATOR
WIRE GUIDEStainless steel
CuffSuture rings
INTRODUCER NEEDLEStainless steel
Order Number
Reference Part Number
Catheter Fr
Catheter Length
cmIntroducer
Fr
Sheath/DilatorLength
cm
Wire Guide Diameter
inch
Single lumen setG07960 C-TPNS-3.0-65-REDO 3 65 3.5 7/11 .018
G07903 C-TPNS-4.0-65-REDO 4 65 5 7/11 .025
G07933 C-TPNS-6.5-90-REDO 6.5 90 7 9/13 .035
G08132 C-TPNS-9.5-90-REDO 9.5 90 10 9/13 .038
Double lumen setG07935 C-TPNS-5.0D-65-12-REDO 5 65 5.5 9/13 .025
G07902 C-TPNS-7.0D-65-REDO 7 65 8 9/13 .035
G29464 C-TPNS-9.0D-90-REDO 9 90 10 9/13 .038
G08074 C-TPNS-12.0D-90-REDO 12 90 13 9/13 .038
Some products or part numbers may not be available in all markets. Contact your local Cook Medical sales representative or Customer Service for details.
DISPOSABLE SYRINGE
Cook TPN
Catheter Repair Set
Set components(Double lumen repair set shown)
• Repair catheter assembly• Adhesive• Luer needle stub• Disposable syringe
Used to repair Cook TPN and TPN REDO catheters.
Order Number
Reference Part Number
Repairs Catheter
Fr
Single lumen setG02120 C-RHCS-3.0 3
G01868 C-RHCS-4.0 4
G01869 C-RHCS-6.5 6.5
G01870 C-RHCS-9.5 9.5
Double lumen setG05498 C-RHCD-5.0 5
G01987 C-RHCD-7.0 7
G02777 C-RHCD-9.0 9
G01977 C-RHCD-12.0 12
Triple lumen setG03538 C-RHCT-8.0 8
Some products or part numbers may not be available in all markets. Contact your local Cook Medical sales representative or Customer Service for details.
ADHESIVE
(Triple lumen repair set shown) LUER NEEDLE STUB
DISPOSABLE SYRINGE
TRIPLE LUMEN REPAIR CATHETER ASSEMBLYSilicone
Tunneller
Order Number
Reference Part Number
CompatibleFr
G20304 IPA-4001 4-7
G20305 IPA-4002 8-12
Some products or part numbers may not be available in all markets. Contact your local Cook Medical sales representative or Customer Service for details.
TUNNELLER
© COOK 02/2019 CC-D45591-EN-F