CHM260 - Spectroscopy Method
-
Upload
alia-najiha -
Category
Technology
-
view
704 -
download
1
description
Transcript of CHM260 - Spectroscopy Method
![Page 1: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/1.jpg)
LECTURE 1
1
![Page 2: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/2.jpg)
The study of the interaction between ELECTROMAGNETIC (EM)
RADIATION and MATTER
2
![Page 3: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/3.jpg)
covers
3
ATOMIC SPECTROSCOPY
(atomic absorption)
MOLECULAR SPECTROSCOPY
(molecular absorption)
![Page 4: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/4.jpg)
What is Electromagnetic Radiation? is a form of energy that has both
Wave and Particle Properties. For example: Ultraviolet, visible,
infrared, microwave, radio wave.
4
![Page 5: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/5.jpg)
5
![Page 6: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/6.jpg)
6
![Page 7: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/7.jpg)
7
![Page 8: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/8.jpg)
EM radiation is conveniently modeled as waves consisting of perpendicularly oscillating electric and magnetic fields, as shown below.
8
Direction of propagation
![Page 9: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/9.jpg)
o At 90° to the direction of propagation is an oscillation in the ELECTRIC FIELD.
o At 90° to the direction of propagation and 90° from the electric field oscillation (orthagonal) is the MAGNETIC FIELD oscillation.
9
![Page 10: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/10.jpg)
Period (p) the time required for one cycle to pass a
fixed point in space. Frequency (V @ f )
the number of cycles which pass a fixed point in space per second. Unit in Hz or s-1
Amplitude (A) The maximum length of the electric
vector in the wave (Maximum height of a wave). Wavelength (λ)
The distance between two identical adjacent points in a wave (usually maxima or minima).
10
![Page 11: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/11.jpg)
Wavenumber (ν) The number of waves per cm in units of cm-1.
Radiant Power ( P )The amount of energy reaching a given area per second. Unit in watts (W)
Intensity ( I )The radiant power per unit solid angle.
11
![Page 12: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/12.jpg)
12
c = 3.00 x 108 m/s = 3.00 x 1010 cm/sc = 3.00 x 108 m/s = 3.00 x 1010 cm/s
Speed of light = Wavelength x Frequency
c = V
Where as is the wavelength of the wavesV is the frequency of the wavesc is the speed of light
Speed of light = Wavelength x Frequency
c = V
Where as is the wavelength of the wavesV is the frequency of the wavesc is the speed of light
![Page 13: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/13.jpg)
Wavelength is inversely proportional to frequency
∝ 1/V The Higher the Frequency the Shorter the
Wavelength . The Longer the Wavelength the Lower the Frequency.
Wavelength is inversely proportional to frequency
∝ 1/V The Higher the Frequency the Shorter the
Wavelength . The Longer the Wavelength the Lower the Frequency.
13
800 nm
Infrared radiationV = 3.75 x 1014 s-1
Ultraviolet radiationV = 7.50 x 1014 s-1
![Page 14: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/14.jpg)
14
EMR is viewed as a stream of discrete particles of energy called photons.We can relate the energy, E of photon to its wavelength, frequency and wavenumber by
E = hV = = hc h = Planck’s constant
h = 6.63 x 10-34 J.s
hc
![Page 15: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/15.jpg)
E = hV = hc
Therefore wavenumber,
= 1/ = V/c
Unit of wavenumber is cm-1
hc
![Page 16: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/16.jpg)
16
What is the energy of a 500 nm photon?
V = c/ = (3 x 108 m s-1)/(5.0 x 10-7 m)
V = 6 x 1014 s-1 @ Hz
E = hV = (6.626 x 10-34 J•s)(6 x 1014 s-1) = 4 x 10-19 J
![Page 17: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/17.jpg)
17
![Page 18: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/18.jpg)
18
Region Wavelength Range
UV 180 – 380 nm
Visible 380 – 780 nm
Near-IR 780 – 2500 nm
Mid-IR 2500 – 50000 nm
![Page 19: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/19.jpg)
19
Region Unit Definition (m)
X-ray Angstrom unit, Å 10-10 m
Ultraviolet/visible Nanometer, nm 10-9 m
Infrared Micrometer, μm 10-6 m
![Page 20: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/20.jpg)
20
![Page 21: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/21.jpg)
21
Atoms are the basic blocks of matter. They consist of heavy particles (called protons
and neutrons) in the nucleus, surrounded by lighter particles called electrons.
![Page 22: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/22.jpg)
22
An electron will interact with a photon. An electron that absorbs a photon will gain
energy. An electron that loses energy must emit a
photon. For absorption to occur, the energy of the
photon must exactly match an energy level in the atom (or molecule) it contacts.◦Ephoton = Eelectronic transition
We distinguish two types of absorption◦Atomic◦Molecular
![Page 23: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/23.jpg)
AbsorptionEMR energy transferred to absorbing molecule (transition from low energy to high energy state).
EmissionEMR energy transferred from emitting molecule to space (transition from high energy to low energy state).
Scatteringredirection of light with no energy transfer.
![Page 24: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/24.jpg)
24
![Page 25: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/25.jpg)
25
Electrons bound to atoms have discrete energies (i.e. not all energies are allowed).
Thus, only photons of certain energy can interact with the electrons in a given atom.
Transitions between electronic levels of the electrons produce line spectra.
![Page 26: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/26.jpg)
26
Consider hydrogen, the simplest atom.
Hydrogen has a specific line spectrum.
Each atom has its own specific line spectrum (atomic fingerprint).
![Page 27: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/27.jpg)
27
The energy of photon that can promote electrons to excite/jump to a higher energy level depends on the energy difference between the electronic levels.
![Page 28: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/28.jpg)
28
Each atom has a specific set of energy levels, and thus a unique set of photon wavelengths with which it can interact.
![Page 29: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/29.jpg)
29
Absorption and emission for the sodium atom in the gas phase.
The diagram illustrate the transitions (excitation and emission) of electrons between different energy levels in sodium atom.
ΔEtransition = E1 - E0 = hv hv = hc/hc/
![Page 30: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/30.jpg)
The energy, E, associated with the molecular bands:
Etotal = Eelectronic + Evibrational + Erotational
In general, a molecule may absorb energy in 3 ways:
1.By raising an electron (or electrons) to a higher energy level. (electronic)
2.By increasing the vibration of the constituent nuclei. (vibrational)
3.By increasing the rotation of the molecule about the axis. (rotational)
![Page 31: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/31.jpg)
Eo
h
Absorption
En
Eo
h
Emission
En
h
![Page 32: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/32.jpg)
Rotational absorption
Vibrational absorption
![Page 33: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/33.jpg)
33
![Page 34: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/34.jpg)
Absorption spectrum◦A plot of the absorbance as a function of
wavelength or frequency.
Emission spectrum◦A plot of the relative power of the
emitted radiation as a function of wavelength or frequency.
34
![Page 35: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/35.jpg)
The two peaks arise from the promotion of a 3s electron to the two 3p states
35
Absorption Spectrum of Na
![Page 36: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/36.jpg)
36
Electronic Transition Vibrational Transition Superimposed on the Electronic Transition
Absorption Band – A series of closely shaped peaks
![Page 37: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/37.jpg)
37
In solvents the rotational and vibrational transitions are highly restricted resulting in broad band absorption spectra.
![Page 38: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/38.jpg)
Three types of spectra: ◦Lines◦Bands◦Continuum spectra
38
Emission spectrum of a brine sample
![Page 39: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/39.jpg)
39
![Page 40: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/40.jpg)
Absorption Spectroscopy
40
Emission Spectroscopy
![Page 41: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/41.jpg)
1. SourceA stable source of radiant energy
at the desired wavelength (or λ range). 2. Sample Holder
A transparent container used to hold the sample (cells, cuvettes, etc.).
3. Wavelength Selector A device that isolates a
restricted region of the EM spectrum used for measurement (monochromators, prisms, & filters).
41
![Page 42: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/42.jpg)
4. Photoelectric Transducer (Detector) Converts the radiant energy into a useable signal (usually electrical).
5. Signal Processor & Readout Amplifies or attenuates the
transduced signal and sends it to a readout device such as a meter, digital readout, chart recorder, computer, etc.
42
![Page 43: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/43.jpg)
Generate a beam of radiation that is stable and has sufficient power. A. Continuum Sources
emit radiation over a broad wavelength range and the intensity of the radiation changes slowly as a function of wavelength.
This type of source is commonly used optical instruments.
Deuterium lamp is the most common UV source.
Tungsten lamp is the most common Visible source.
Glowing inert solids are common sources for IR.
43
![Page 44: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/44.jpg)
B. Line Sources Emit a limited number lines or bands of radiation at specific wavelengths. Used in atomic absorption spectroscopy.
Types of line sources: 1.Hollow cathode lamps 2.Electrodeless discharge lamps 3.Lasers (Light amplification by stimulated emission of radiation)
44
![Page 45: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/45.jpg)
Sample containers usually is called cells or cuvettes, must have side/windows that are transparent in the spectral region of interest.
There are few types of cuvettes1. quartz or fused silica (below 350nm)
required for UV & VIS region
2. silicate glass (350 – 2000nm)cheaper compared to quartz. Used in VIS
3. crystalline sodium chlorideused in IR 45
![Page 46: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/46.jpg)
Wavelength selectors provides a limited, narrow, continuous group of wavelengths called a band.
Two types of wavelength selectors: A) FiltersB) Monochromators
46
![Page 47: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/47.jpg)
47
![Page 48: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/48.jpg)
48
Early detectors in spectroscopic instruments were the human eye, photographic plates or films. Modern instruments contain devices that convert the radiation to an electrical signal.
Two general types of radiation transducers:a. Photon detectors b. Thermal detectors
![Page 49: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/49.jpg)
Commonly useful in ultraviolet, visible and near infrared instruments.Several types of photon detectors are available:
1. Vacuum phototubes 2. Photomultiplier tubes 3. Photovoltaic cells 4. Silicon photodiodes 5. Diode array transducers 6. Photoconductivity transducers
A. Photon Detectors
49
![Page 50: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/50.jpg)
B. Thermal DetectorsUsed for infrared spectroscopy because
photons in the IR region lack the energy to cause photoemission of electrons.
Three types of thermal detectors: 1. Thermocouples2. Bolometers 3. Pyroelectric transducers
50
![Page 51: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/51.jpg)
SPECTROMETERis an instrument that provides information
about the intensity of radiation as a function of wavelength or frequency.
SPECTROPHOTOMETERis a spectrometer equipped with one or more
exit slits and photoelectric transducers that permits the determination of the ratio of the radiant power of two beams as a function of wavelength as in absorption spectroscopy. 51
![Page 52: CHM260 - Spectroscopy Method](https://reader033.fdocuments.us/reader033/viewer/2022061221/54bdd16f4a7959731e8b45aa/html5/thumbnails/52.jpg)
REGION SOURCE SAMPLE HOLDER
DETECTOR
Ultraviolet
Deuterium lamp Quartz /fused silica
Phototube, Photo
Multiplier tube, diode
array
Visible Tungsten lamp Silicate Glass /Quartz
Phototube, Photo
Multiplier tube, diode
array
Infrared Nernst glower (rare earth oxides or silicon carbide
glowers)
Salt crystals (crystalline
sodium chloride)
Thermocouples, bolometers
52