ELECTRONIC HID BALLASTS
Commercial
Lighting
Industrial Lighting
Street Lighting
Horticultural Lighting
2-6
7-11
12-13
14-15
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 2/162
Definition:
Electronic ballasts for applications with low wattage Metal
Halide (MH) or Ceramic Metal Halide (CDM) lamps
Applications:
Business lighting, office lighting, residential lighting, stage
lighting, architectural lighting, decorative lighting, advertising
lighting, and more
Features and Benefits:
• More stable operation and faster warm-up time
• Fulham’s Electronic HID Ballasts extend lamp life up to 30%
• Fulham’s low wattage, low frequency Electronic HID
Ballasts compensate for input voltage fluctuations and
provide icker-free operation
• Lamp End-Of-Life (EOL) protection
• Improved thermal performance
COMMERCIAL LIGHTING BALLASTS 20, 39, 70, 150 WATT 230V for MH/CDM Lamps
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 3/163
1
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH MOUNTING HEIGHT WEIGHT
110mm (4.37") 75mm (2.95") 32mm (1.26") 97.5mm (3.84") 63.5mm (2.50") 27.5mm (1.08") 0.28kg (0.62lb)
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH MOUNTING HEIGHT WEIGHT
164mm (6.45") 91mm (3.58") 38mm (1.50") 154mm (6.06") 68.5mm (2.7") 29.5mm (1.16") 0.56kg (1.23lb)
Compliances and Approvals:
• ISO 9001
Performance Requirements:
Input Voltage: 220-240 V, 50/60Hz
Voltage Range: +/-10% of rated voltage
Total Harmonic Distortion (THD):
20W: <20%
39W, 70W, 150W: <15%
Operating Frequency (Typical): 175Hz
Crest Factor: <1.5
Protections:
• Lamp End-Of-Life (EOL) protection• Short circuit protection
• Open circuit protection
Installation and Application Notes:
• Ambient Temperature: -20°C through +55°C
• Ignition pulse is 3-4kV max
• Remote Mounting up to 1.5m
• Power to lamp must be cycled (on/off/on) after replacing lamp
• Ballast output will shut down after 30 minutes if lamp fails to ignite
COMMERCIAL LIGHTING BALLASTS20, 39, 70, 150 WATT 230V for MH/CDM Lamps
CATALOG NUMBERINPUT VOLTS
(V)
LINE CURRENT
(A)
INPUT POWER
(W)
MINIMUM
POWER FACTOR
TC MAX
(ºC)
CASE &
WIRING DIAGRAM
20 1 H1-230-20HSC 220-240 0.11 25 ≥ 0.90 80 1
39 1 H2-230-35HSC 220-240 0.20 44 ≥
0.95 80 1
70 1 H5-230-70HSC 220-240 0.35 78 ≥ 0.95 80 1
150 1 HXX-230-150-HBTCS 220-240 0.77 167 ≥ 0.95 80 2
LAMP DATA
WATTS NUMBER
(Please inquire about 50W and 100W models)
7 5
6 3 . 5
97.5
3 2
2 7 .
5
110
6.5
110
97.5
164
3 8
6 8 .
5
9 1
154
2 9 . 5
1 1 .
2 5
2
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 4/164
COMMERCIAL LIGHTING BALLASTS20, 39, 50 WATT 120V for MH/CDM Lamps
20, 39, 50, 70, 100, 150, 175 WATT 120-277V for MH/CDM Lamps
Definition:
Electronic ballasts for applications with low wattage Metal
Halide (MH) or Ceramic Metal Halide (CDM) lamps
Applications:Business lighting, office lighting, residential lighting, stage
lighting, architectural lighting, decorative lighting, advertising
lighting, and more
Features and Benefits:
• More stable operation and faster warm-up time
• Fulham’s Electronic HID Ballasts extend lamp life up to 30%
• Fulham’s low wattage, low frequency Electronic HID
Ballasts compensate for input voltage fluctuations and
provide icker-free operation
• Lamp End-Of-Life (EOL) protection
• Improved thermal performance
CATALOG
NUMBER
INPUT VOLTS
(V)
LINE CURRENT
(A)
INPUT POWER
(W)
MINIMUM
POWER FACTOR
CASE &
WIRING DIAGRAM
20 1 M156,C156,C175,M175 H1-120-22HSC 120 0.21 ≥ 0.98
39 1 M130,C179,C130
120 0.37 ≥ 0.98
50 1 M110,M1148 120 0.49 ≥ 0.98
LAMP DATA
WATTS NUMBER ANSI CODE
H3-120-39HSC
H4-120-50HSC
25
44
57
3
3
3
20 1 M156,C156,C175,M175 HXX-UNV-20-HBBCK 120-277 24 ≥ 0.90
39 1 M130,C179,C130 120-277 44 ≥ 0.90
50 1 M110,M1148 120-277 58 ≥ 0.90
70 1 C/M98,C/M139,C/M143 120-277 78 ≥ 0.90
100 1 M90,M140,M164 120-277 111 ≥ 0.95
150 1 M102,M142,M/C142,
M81/M107 120-277 164 ≥ 0.95
175 1 M57,M152,M137 120-277 195 ≥ 0.95
H3-UNV-39HSC
H3-UNV-39HBC
HXX-UNV-50-HBSCK
HXX-UNV-50-HBBCK
H5-UNV-70HSC
H5-UNV-70HBC
H7-UNV-150HSC
H6-UNV-100HSC
H7-UNV-150HBC
H6-UNV-100HBC
H8-UNV-175HSC
H8-UNV-175HBC
0.10A/277V
0.21A/120V
0.18A/277V
0.37A/120V
0.21A/277V
0.48A/120V
0.29A/277V
0.66A/120V
0.42A/277V
0.97A/120V
0.61A/277V
1.54A/120V
0.71A/277V
1.78A/120V
5
4
5
4
5
4
5
4
5
4
7
6
7
6
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 5/165
COMMERCIAL LIGHTING BALLASTS20, 39, 50 WATT 120V for MH/CDM Lamps
20, 39, 50, 70, 100, 150, 175 WATT 120-277V for MH/CDM Lamps
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
140mm (5.51") 91.5mm (3.60") 38mm (1.50") 131mm (5.16") 73.5mm (2.89") 0.59kg (1.30lb)
4
123
131
7 3 . 5
9 1 . 5
38
50.5
16 white
black
green
red
blue
ACpower
1
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
95mm (3.74") 75mm (2.95") 30.5mm (1.20") 87mm (3.43") 65mm (2.56") 0.28kg (0.62lb)
3
white
black
green
redblue
ACpower
6 5
87
89
95
7 5
30.5
Compliances and Approvals:
• cULus Listed (Outdoor Type 1)
• FCC Part 18, for Non-Consumer Equipment
• ISO 9001
Performance Requirements:
Input Voltage: See chart on previous page for
120V and UNV 120-277 V, 50/60Hz models
Voltage Range: +/-10% of rated voltage
Total Harmonic Distortion (THD):
20W: <25%
39W, 50W, 70W, 100W: <20%
150W, 175W: <15%
Operating Frequency (Typical): 175Hz
Crest Factor: <1.5
Protections:
• Lamp End-Of-Life (EOL) protection
• Short circuit protection
• Open circuit protection
• Ignition failure protection
• Thermal protection, UNV 120-277V models only
Installation and Application Notes:
• Ambient Temperature: -20°C through +55°C
• Ignition pulse is 3-4kV max
• Remote Mounting up to 1.5m
• Power to lamp must be cycled (on/off/on) after replacing lamp
• Ballast output will shut down after 30 minutes if lamp fails to ignite
E328229
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 6/166
COMMERCIAL LIGHTING BALLASTS20, 39, 50 WATT 120V for MH/CDM Lamps
20, 39, 50, 70, 100, 150, 175 WATT 120-277V for MH/CDM Lamps
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
164mm (6.46") 91.5mm (3.60") 38mm (1.50") 155mm (6.10") 73.5mm (2.89") 0.70kg (1.54lb)
7
147
155
7 3 . 5
9 1 . 5
38
164
white
black
green
red
blue
ACpower
6
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
164mm (6.46") 91.5mm (3.60") 38mm (1.50") 155mm (6.10") 73.5mm (2.89") 0.70kg (1.54lb)
147
155
7 3 . 5
9 1 . 5
38
164
50.5
16 white
black
green
redblue
ACpower
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
140mm (5.51") 91.5mm (3.60") 38mm (1.50") 131mm (5.16") 73.5mm (2.89") 0.59kg (1.30lb)
123
131
7 3 . 5
9 1 . 5
38
white
black
green
red
blue
ACpower
5
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 7/167
INDUSTRIAL LIGHTING BALLASTS 250, 400 WATT 230V for MH/HPS Lamps
Definition:
Electronic ballasts for applications with low wattage Metal
Halide (MH) or High Pressure Sodium (HPS) lamps
Applications:Widely used in street lighting, stadium lighting, and industrial lighting
Features and Benefits:
• Designed and manufactured with premium long-life
components
• Dimming options available, such as: 0-10V, preset program
dimming, and step dimming• Communications protocol: Zigbee, DALI, and GSM
• Easy initial installation or eld replacement of magnetic
ballasts
• Fulham’s Electronic HID Ballasts compensate for input
voltage uctuations and provide icker-free operation
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 8/168
INDUSTRIAL LIGHTING BALLASTS 250, 400 WATT 230V for MH/HPS Lamps
CATALOG NUMBER INPUT VOLTS
(V)
LINE CURRENT
(A)
INPUT POWER
(W)
MINIMUM
POWER FACTOR
TC MAX
(ºC)
CASE &
WIRING DIAGRAM
250 1 HGE-230-250-JSSLK 220-240 1.23 275 ≥ 0.98 80 8
400 1 HGE-230-400-JSSLK 220-240 1.93 430 ≥ 0.98 80 8
LAMP DATA
WATTS NUMBER
Compliances and Approvals:
• CE Marking
• ISO 9001
Performance Requirements:Input Voltage: 220-240V, 50/60Hz
Voltage Range: +/-10% of rated voltage
Total Harmonic Distortion (THD): <10%
Operating Frequency (Typical): 70-120kHz
Crest Factor: <1.7
Protections:
• Lamp End-Of-Life (EOL) protection
• Short circuit protection
• Open circuit protection
• Ignition failure protection
• Thermal protection
Installation and Application Notes:
• Ambient Temperature: -30°C through +50°C
• Ignition pulse is 5kV max
• Remote Mounting up to 1.5m
• Power to lamp must be cycled (on/off/on) after replacing lamp
• Ballast output will shut down after 30 minutes if lamp fails to ignite
8
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
214mm (8.43") 98.5mm (3.88") 58.7mm (2.31") 202mm (7.95") 80mm (3.15") 1.3kg (2.87lb)
8 0
9 8 .
5
214
187
5 8 .
7
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 9/169
INDUSTRIAL LIGHTING BALLASTS 250, 400 WATT 230V for MH/CDM Lamps
CATALOG NUMBERINPUT VOLTS
(V)
LINE CURRENT
(A)
INPUT POWER
(W)
MINIMUM
POWER FACTOR
TC MAX
(ºC)
CASE &
WIRING DIAGRAM
250 1 HXE-230-250-HBSLS 220-240 1.23 275 ≥ 0.98 80 9
400 1 HXE-230-400-HBSLS 220-240 1.93 430 ≥ 0.98 80 9
LAMP DATA
WATTS NUMBER
Definition:
Electronic ballasts for applications with low wattage Metal
Halide (MH) or Ceramic Metal Halide (CDM) lamps
Applications:
sculptured eaves, and more
Features and Benefits:
• More stable operation and faster warm-up time
• Fulham’s Electronic HID Ballasts extend lamp life up to 30%
• Fulham’s low wattage, low frequency Electronic HID
Ballasts compensate for input voltage fluctuations and
• Lamp End-Of-Life (EOL) protection
• Improved thermal performance
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
240mm (9.44") 95mm (3.74") 65mm (2.56") 226mm (8.90") 40mm (1.57") 0.85kg (1.87lb)
9 6
5
6
4 0
2 6
210
240
226
9 5
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 10/1610
INDUSTRIAL LIGHTING BALLASTS 140, 150 WATT 230V and 150 WATT 120-277V for use with:
PHILIPS CosmoWhite 140W Lamps
GE StreetWiseTM 150W Lamps
SYLVANIA Urban White 140W Lamps
Definition:
Electronic ballasts for applications with low wattage Metal
Halide (MH) or Ceramic Metal Halide (CDM) lamps
Applications:
Outdoor: Road lighting, port lighting, recreational
park lighting, etc.
Indoor: Large (highbay) retail outlets, warehouses,
manufacturing facilities, etc.
Features and Benefits:
• Designed for newer energy efcient lamps
• Up to 118lm/W, perfect for OEM or retrot applications
• 2800K color temperature, Ra 66
• Compact housing is easy to install and suitable for small lamp xtures
• Up to 20,000 hours lifetime
• 50%-100% dimming
• Waterproof rating: IP65
• Improved thermal performance
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 11/1611
INDUSTRIAL LIGHTING BALLASTS 140, 150 WATT 230V and 150 WATT 120-277V for use with:
PHILIPS CosmoWhite 140W Lamps
GE StreetWiseTM 150W Lamps
SYLVANIA Urban White 140W Lamps
CATALOG NUMBERINPUT VOLTS
(V)
LINE CURRENT
(A)
INPUT POWER
(W)
MINIMUM
POWER FACTOR
TC MAX
(ºC)
CASE &
WIRING DIAGRAM
140 1 HXX-230-140-HSSLW 220-240 0.71 156 ≥ 0.95 80 10
150 1 HXE-230-150-JSSLW 220-240 0.77 167 ≥ 0.95 80 10
150 1 HXX-UNV-150-JSSLW 120-2771.54@120V
0.61@277V 167 ≥ 0.95 80 10
LAMP DATA
WATTS NUMBER
10
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
182mm (7.17") 113mm (4.45") 41mm (1.61") 173mm (6.81") 70mm (2.76") 1.23kg (2.71lb)
160
4 1
173
182
7 0
1 1 3
Compliances and Approvals:
• cULus Listed (Outdoor Type 1)
• FCC Part 18, for Non-Consumer Equipment
• ISO 9001: 2008
Performance Requirements:
Input Voltage: See above chart for 230V and
UNV 120-277 V, 50/60Hz models
Voltage Range: +/-10% of rated voltage
Total Harmonic Distortion (THD):
220-240V 140W, 150W: <10%
120-277V 150W: <15%
Operating Frequency (Typical): 175Hz
Crest Factor: <1.7
Protections:
• Lamp End-Of-Life (EOL) protection
• Short circuit protection
• Open circuit protection
• Ignition failure protection
• Thermal protection
Installation and Application Notes:
• Ambient Temperature: -30°C through +50°C
• Ignition pulse is 5kV max
• Remote Mounting up to 1.5m• Power to lamp must be cycled (on/off/on) after replacing lamp
• Ballast output will shut down after 30 minutes if lamp fails to ignite
E328229
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 12/1612
STREET LIGHTING BALLASTS150 WATT 230V for MH/HPS Lamps
Around the globe, “green” technology is quickly becoming the
preferred choice for lighting due to its energy saving
properties and ROI potential. At Fulham, we are committed to
promoting the adoption of cost efficient lighting technologiesin new elds. For example, we offer a complete EHID road lighting
solution that reduces power consumption by 40-60% compared
with traditional street lights.
Features and Benefits:
• Easily retrot existing magnetic ballast applications
• One Fulham Electronic HID ballast replaces a magnetic ballast,
capacitor, and ignitor• More stable operation and faster warm-up time
• Fulham’s Electronic HID Ballasts extend lamp life up to 30%
• Fulham’s low wattage, low frequency Electronic HID
Ballasts compensate for input voltage fluctuations and
provide icker-free operation
• Lamp End-Of-Life (EOL) protection
• Improved thermal performance
• Waterproof rating: IP65
Applications:
Street lighting, port lighting, recreational park lighting, etc.
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 13/1613
STREET LIGHTING BALLASTS
150 WATT 230V for MH/HPS Lamps
11
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT182mm (7.17") 113mm (4.45") 41mm (1.61") 173mm (6.81") 70mm (2.76") 1.23kg (2.71lb)
Performance Requirements:
Input Voltage: 220-240V, 50/60Hz
Voltage Range: +/-10% of rated voltage
Total Harmonic Distortion (THD): <15%
Operating Frequency (Typical): 175Hz
Crest Factor: <1.7
Protections:
• Lamp End-Of-Life (EOL) protection
• Short circuit protection
• Open circuit protection
• Ignition failure protection
• Thermal protection
Installation and Application Notes:
• Ambient Temperature: -40°C through +50°C
• Ignition pulse is 5kV max
• Remote Mounting up to 1.5m
• Power to lamp must be cycled (on/off/on) after replacing lamp
• Ballast output will shutdown after 30 minutes if lamp fails to ignite
4 1
CATALOG
NUMBER
INPUT VOLTS
(V)
LINE CURRENT
(A)
INPUT POWER
(W)
MINIMUM
POWER FACTOR
TC MAX
(ºC)
CASE & WIRE
DIAGRAM
150 1 MH&HPS HGE-230-150-JSSLW 220-240 0.77 167 ≥ 0.95 80 11
LAMP DATA
WATTS NUMBER SOURCE
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 14/1614
HORTICULTURAL LIGHTING BALLASTS
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 15/1615
CATALOG NUMBER NOTES APPROVAL INPUT VOLTAGE (V) INPUT CURRENT (A) INPUT POWER (W) LAMP TYPE (W/V)
HXX-277-1K-JGSHW 277 3.9 1050 1000/400
HXX-480-575-JGSCW 480 1.3 605 575/230
HXX-277-600-JGSHW 277 2.3 645 600/400
HXX-347-600-JGSHW 347 1.9 645 600/400
HXX-480-600-JGCUS UL 480 1.37 645 600/400
HPX-MLT-600-JGSLB UL 120-240 5.5/2.75 650/630 600/230
HPX-MLT-600-JGSLK UL 120-240 5.5/2.75 650/630 600/230
HPX-MLT-600-JGSLM1 3 step
dimming model UL 120-240 5.5/2.75 650/630 600/230
HXX-MLT-600-JGSLM UL 120-240 5.5/2.75 650/630 600/230
HXX-277-750-JGSHW 277 2.91 790 750/400
HXX-347-750-JGCUS UL 347 2.31 790 750/400
HXX-277-1K-JGTUS UL 277 3.85 1050 1000/400
HXX-347-1K-JGTUS UL 347 3.07 1050 1000/400
HXX-347-1K-JGSHW 347 3.07 1050 1000/400
HXA-400-1K-JGSHW 400 2.61 1045 1000/400
HPX-MLT-1K-JGSLK UL 120-240 9.2/4.5 1110/1070 1000/400
HPX-MLT-1K-JGSLM1 3 step
dimming model UL 120-240 9.2/4.5 1110/1070 1000/400
HXX-MLT-1K-JGSLB UL 120-240 9.2/4.5 1110/1070 1000/400
HXX-MLT-1K-JGSLM UL 120-240 9.2/4.5 1110/1070 1000/400
HXX-230-600-SGTLS 230 2.85 645 600/230
HXE-230-600-SGCUS 230 2.85 645 600/400
HXX-347-600-SGCUS 347 1.88 645 600/400
HXX-347-600-SGSHW 347 1.9 645 600/400
HXX-347-750-SGCUS 347 2.31 790 750/400
HME-400-750-SGCUS 400 1.98 790 750/400
HXE-400-750-SGTUS 400 1.98 790 750/400
HXE-400-750-SGCUS 400 1.98 790 750/400
HXE-400-1K-SGTUS 400 2.61 1045 1000/400
HXX-480-750-JGSCW 480 1.68 790 750/400
HXX-480-750-JGCUS UL 480 1.68 790 750/400
HXE-400-600-SGTUS 400 1.61 645 600/400
HXX-380-600-SGSHW 380 1.37 645 600/400
HPX-MLT-1K-JGSLG1 UL 120-240 9.2/4.5 1110/1070 1000/400
HXX-MLT-600-JGSLW UL 120-240 5.5/2.75 650/630 600/230
HXX-MLT-1K-JGSLW UL 120-240 9.2/4.5 1110/1070 1000/400
HORTICULTURAL LIGHTING BALLASTS
8/18/2019 China EHID Ballast Brochure FINAL 1013
http://slidepdf.com/reader/full/china-ehid-ballast-brochure-final-1013 16/16
Fulham Latin America
(Latin America)
12705 S. Van Ness Avenue
Hawthorne, CA 90250
U.S.A.
Tel: (407) 758-2564
Fulham Company GmbH (Europe)
Karolinenstrasse 18D-58507 Lüdenscheid
Germany
Handelsregister Iserlohn: HR B 6286
USt.-IdNr.: DE253959344
Fon: +49 2351 4327416
Fax: +49 2351 6567349
Mobile: +49 152-0-9838495
Fulham Company Ltd. (Middle East)
LOB-2, No 127 P.O. Box 261051
Jebel Ali Free Zone, Dubai, UAE
Tel: +9714-8873577
Fax: +9714-8873599
Fulham (India) Pvt. Ltd.
343, Kaliandas Udyog Bhavan
Sadanand Tandel Marg
Near Century Bazar, Prabhadevi
Mumbai - 400025
Tel: +91 22 66388775-9
Fulham (India) Pvt. Ltd.Survey No. 26-3
Village Narhe
Taluka Haveli,
District: Pune 411041
Tel: +91 20 24690703/4
Fax: +91 20 24690712
Fulham Headquarters (USA)
12705 S. Van Ness Avenue
Hawthorne, CA 90250
Tel: (323) 599-5000
Fax: (323) 754-9060
www.fulham.com
Fulham Company Ltd. (International)
Unit6
,6 /F, Kowloon Plaza485 Castle Peak Road
Cheung Sha Wan, Kowloon
Hong Kong
Tel: +852-2314-4801
Fax: +852-2314-4186
Fulham Electronic Co. Ltd. (North China)
No. 9 Xingchang Road, Nanshaozhen
Changping Science Park
Beijing 102200
P.R. China
Tel : +86-10-6073-5858Fax : +86-10-6073-3765
Fulham Electronic Co. Ltd. (South China)
Room 1402, Block D, The First Place
Wealth Centre
No. 200 Hongfu Road
The South Dongguan City,
Guangdong Province
P.R. China
Tel: +0769-2202 7555
Fax: +0769-2202 7553
Fulham Electronic Co. Ltd. (Central China)
Room 312-315, Xing Yuan
Technology Plaza
No 418, Gui Ping Road
Caohe-Jing Hi-Tech Park
Shanghai, P.R. China
Post Code: 200233
Tel: +86-021-6495-2777
Fax: +86-021-5426-5271
Fulham Co., Inc. (Canada)
24 Kicking Horse Way
Port Moody, BC, Canada, V3H 0G5
Tel: (604) 288-2609
Fax: (604) 648-9065
www.fulham.com/chinese