GENERAL chillers thermal storage systems generalcatalogue. rc group spa • c_gnr_0507 3 r c group...
Transcript of GENERAL chillers thermal storage systems generalcatalogue. rc group spa • c_gnr_0507 3 r c group...
GENERALAIR CONDITIONERS
ROOF TOP
FAN COILS
LIQUID CHILLERS
MULTIFUNCTION CHILLERS
CONDENSERLESS CHILLERS
AIR COOLED CONDENSERS
DRY COOLERS
ABSORPTION CHILLERS
THERMAL STORAGE SYSTEMS
GENERALCATALOGUE
4 RC GROUP SpA • C_GNR_0507
0 75 150 225
15
19
25
31
35
39
49
57
53
0 7 14 21 kW
19
25
39
0 75 150 225 kW
kW
5 20
5 104
7 160
40 161
8 52
53 225
4 14
5 15
4 19
6 86
5 110
54 233
air conditioners / roof-top
CONSOLER407C # U . O # DX . DW . CW # C
PEGASUSR407C # U . O # DX . DW . CW # C
neXtR407C # U . O # DX . DW . CW . CW.K # C . P
COMPACTU . O # CW.K # C
HEAT.HUNTERR407C # DL # DX . DW . CW # C
ROOF.TOPR407C # U . OR # DX # C
• page
INDEX
REFRIGERANT : R407C / R134a / R410AAIR DELIVERY : O - UPFLOW / U - DOWNFLOW / DL - DISPLACEMENT / OR - HORIZONTALVERSION : DX - AIR COOLED / DW - WATER COOLED / CW - CHILLED WATER FEEDING /
CW.K - CHILLED WATER FEEDING IN COMPACT VERSIONFAN TYPE : C - CENTRIFUGAL / P - PLUG FAN
air conditioners for TLC
ENERGY.SPLITR407C # O # DX # C
ENERTELR407C . R134a # O . U . DL # DX # C
MINIPACR407C # O # DX # C
heat pump air conditioners / roof-top
PEGASUSR407C # O # DX . DW # C
neXtR407C # O # DX . DW # C . P
ROOF.TOPR407C # U . OR # DX # C
• page
• page
5RC GROUP SpA • C_GNR_0507
69
61
73
79
87
87
0 500 1000 1500
101
kW0 500 1000 1500
117
111
kW0 200 400 600
kW
21 1675
42 148
62 626
5 41
6 52
48 505
21 1475
189 1538
199 1613
INDEX
air cooled liquid chillers
EASY “R”R407C # Z # A
CILLI.IDROCOMPLR407C # Z # A . C
EASYR407C # Z # A
UNICOR407C . R134a # Z . F . S . V # A . C
GLIDERR134a # V # A
GLIDER.CLAR134a # V # A
• page
air cooled liquid chillers with free-cooling system
MAXIMOR407C . R134a # Z . F . S . V # A . C
air cooled multifunction chillers
TRILOGYR410A # Z # A
MULTIPLOR407C . R134a # Z . F . V # A . C
REFRIGERANT : R407C / R134A / R410ACOMPRESSOR : Z - SCROLL / R - ROTARY / V - SCREW / F - RECIPROCATING / S - AMP RECIPROCATINGFAN TYPE : A - AXIAL / C - CENTRIFUGAL
• page
• page
6 RC GROUP SpA • C_GNR_0507
61
123
129
kW0 200 400 4000
kW0 250 500 1000
69
61
73
93
87
61
123
129
kW0 200 400 3000
kW0 135 265 400
123
6 49
7 59
59 592
188 1077
25 1079
6 60
32 379
127 4138
50 400
6 52 7 60
28 35130 380
310 3444
INDEX
water cooled liquid chillers
AQUA.IDROCOMPLR407C # Z
COLDPACK.WR407C # Z
FRIGO.WR407C . R134a # S . V
• page
heat pump liquid chillers air / water
EASY “R”R407C # Z # A
CILLI.IDROCOMPLR407C # Z # A . C
EASYR407C # Z # A
REVERSOR407C . R134a # Z . F . S # A . C
GLIDER.HPR134a # V # A
• page
REFRIGERANT : R407C / R134A / R410ACOMPRESSOR : Z - SCROLL / R - ROTARY / V - SCREW / F - RECIPROCATING / S - AMP RECIPROCATINGFAN TYPE : A - AXIAL / C - CENTRIFUGAL
condenserless chillers / heat pumps
DIVI.IDROCOMPLR407C # Z
COLDPACK.AR407C # Z
FRIGO.AR407C . R134a # S
• page
water cooled heat pump liquid chillers water / water
COLDPACK.W.PR407C # Z
• page
7RC GROUP SpA • C_GNR_0507
137
kW0 200 400 600
143
kW0 1500 3000 4500
147
kW0 250 500 750
43
43
43
kW0 4 8 12
137
kW0 135 265 400
107 4928
8 665
13 390
2 4
2 10
1 11
170 670
INDEX
HEAT SOURCE : WF - HOT WATER / SF - STEAM / GF - METHANE GASREFRIGERANT : R407C / R134a / R410AFAN TYPE: A - AXIAL / C - CENTRIFUGAL / T - TANGENTIAL
water cooled absorption chillers (LiBr)
THERMOFRIGOWF . SF . GF
• page
• page
air cooled condensers
TEAM MATE.DXA . C
• page
fan coils
SPRINGT
SKY WATERC
FCR / FCT C . T
thermal storage systems
ICE.BANK.LEVLOAD
• page
• page
dry coolers air/water
TEAM MATE.DCA . C
8 RC GROUP SpA • C_GNR_0507
COMPANY PROFILE
INNOVATIVE, DYNAMIC BUSINESS
spirit and a pervasive innovative drive. Founded in 1963 as RC Condizionatori, we have
commitment to creating innovation.
-
designed for a computer centre of a leading Italian bank.
A CHOICE THAT BLAZED TRAILS
as we succeeded in establishing the trend of installing air conditioning machines in com-
as the decline of large mainframe computers and the establishment of distributed infor-
telecommunications to servers.
INFORMATION TECHNOLOGYAnother important element of our leadership is our high degree of computerization that is often ahead of the times and
This was a bold, forward-thinking step, which laid the foundations-
ced three-dimensional CAD program, which allows us to conside-
market.
-nects our three production divisions in real time, exchanging sound,
product information.
1963
RC GROUP
9RC GROUP SpA • C_GNR_0507
COMPANY PROFILE
IMPRESSIVE TECHNOLOGICAL GROWHT
Since the nineties, our strong innovative drive has translated into one of the most advanced product ranges in the
THREE PRODUCTION CENTRES
-tes, in producing close control air conditioners for technological environments.RC Group is organized in three production divisions:
power air conditioners for technological environments.
-
10 RC GROUP SpA • C_GNR_0507
MANAGEMENT SY
STEM
C
ERT I F I E D
COMMERCIAL ORGANIZATION--
At the RC Group, one of our most special qualities is our total openness to sharing know-how with Designers, Au-thorized Service Centres, Distributors and our closest Partners. For instance, we prefer to transfer our know-how to
-
our services.
FUTURE-READY SOLUTIONS
awareness has grown, both on the part of more sensitive and attentive customers, HVAC designers and with high qua-
-
ISO 9001 CERTIFICATION
-cations
COMPANY PROFILE
www.rcgroup.it
11RC GROUP SpA • C_GNR_0507
INFORMATION TECHNOLOGY & COMMUNICATIONS
Comvik, EDS, France Telecom, Global Crossing, Hermes, Indosat, Ir i tel, I taltel, KPN, KPN Qwest, LDCom, Level 3,
Mannesman, MCI Worldcom, Metroweb, Motorola, Netsiel, OTE, Pasif ik Satel it Nusantara, Polish Telecom, Portugal
Telenokia, Telenor, Tel ia, Telkom, Telnet, Transpac, Unifon, Unisource.
Communications, Mobilcom, Motorola, Netcom GSM, Nokia, O-Tel-O, Omnitel, OTE, Orange, Proximus, PtcTelecom,
Retevision Movi l , Siemens, Sveriges Radio, Telecom Ital ia Mobi le, Telefonica Movi les, Wind.
BANKSABN Bank, Alembank, AMRO Bank, Banca Agricola Milanese, Banca Arner, Banca Commerciale Ital iana, Banca
Regionale Europea, Banca Sel la, Banca Toscana, Banco Ambrosiano Veneto, Bank of China Hua Qiao, Banque
Postbank, Rabo Bank, Swiss Bank Corporation, Unicredit, Union Bank of Switzerland.
OFFICE BUILDINGSACI, Allianz Platz, Aok, Assicurazioni Generali, Bvk, Canal+, Club Med, Continentale, Eastern Pearl TV Tower, Fininvest, Ger-
ail, Videotime, Zbc.
PUBLIC BODIES
Government, Bundesbauddirektion Langer Eugen - Bonn, Bundeslander Versicherung - Wien, Camera dei Deputati,
PUBLISHING INDUSTRIES
Lombarda.
ELECTRONIC INDUSTRIES
Ibm, Intel, I taltel, Magneti Marel l i , Ol ivett i , Schneider Electr ic, Siemens, Telettra, Toshiba, Whirpool.
CHEMICAL & PHARMACEUTICAL INDUSTRIESAgip, Du Pont, Enichem, Esso Ital iana, Fisba Optik, Montell, Parek Chemical, Polfa, Procter & Gamble, Sika, Tioxide.
Janssen, Pharmaceutica, Johnson & Johnson, Merk Sharp & Dome, Novart is, Parek Chemicals, Pharmacia &
REFERENCE
12 RC GROUP SpA • C_GNR_0507
MECHANICAL & STEEL INDUSTRIESAcciai Special i Terni , Acciaier ie Piombino, Alenia, Ansaldo, BMW, Bosch, Costruzioni Areonaut iche Agusta,
sott i le, Lucas Industr ies, Luxott ica, Magneti Marel l i , Magona, Merloni, Nissan, Nuova Magrini Gal i leo, Ocean, Opel,
Renault, Sandvik, Skf, Trumpf, Valeo, Volkswagen.
FOOD INDUSTRIESBar i l la , CocaCola, Dolma, Gancia, Heineken, Hi lcona, L ipton, Master foods, Misura, Nest lé, Rana, Plasmon,
Stol lwerk, Uni lever.
LEISURE & ENTERTAINMENT
Pablo Picasso Museum - Munster, Palazzo Civran Badoer - Venezia, Palazzo Ducale - Genova, Sport ing Centre
UNIVERSITIES
College London, Universidade Augiro - Aveiro, Università Cattol ica - Milano, Università di Bologna, Università
SHOPPING CENTRES
Center Targowek - Warsawa, Conad, Coop, Domus, El Corte Ingles, Esselunga, Euromercato, Hipercor, Ica
Maxi, Ikea, La Rinascente, Oviesse, Rathausgaler ie - Wuppertal, Rubens - Berchem, Sc Uno, Stovner Centre
- Oslo, UPIM, World Trade Centre - Cardif f .
TRANSPORTAereoporto Marco Polo - Venezia, Aeroporto di Fiumicino - Roma, Aeroporto di Peretola - Firenze, Aeroporto F.
Airport, Johannesburg Airport, S.n.c.b. - N.m.b.s. - Bruxelles, Shanxi Hong Kong, Shipol Amsterdam, Wan Hai Airport
- Wan Hai, Wu Han Station - Wu Han, Zurich Airport.
HOSPITALSA.He.Pa - Thessalonik i , BPA Vent Montor - Linkoping, Chirurgische Kl in ik - Munster, Cl in ique des Grangettes
- Geneva, H. Fami l le - Reet, Hospita l Cheux de Fonds, Hospita l Civ i l - Char leroi , Hospita l Santana - Lisbon,
Hospita l of Chur, Hospita l of Schiers, Ist i tuto Gasl in i - Genova, Ist i tuto Tumori di Mi lano, Kantonsspita l - Olten,
Kl in ikum - Wupperta l , Krankenhaus - Waldbrol , Meb Nuclearmediz in - Bonn, Middelheim - Antwerpen, Ospadale
Ospedale Civ ico di Palermo, Ospedale Civ i le di Pescara, Ospedale Civ i le di Treviso, Ospedale di Alessandr ia,
Ospedale di Belluno, Ospedale di Bolzano, Ospedale di Brunico, Ospedale di Como, Ospedale di Sondrio, Ospedale
Gal l iera - Genova, Ospedale Ger iatr ico - Sospiro, Ospedale S. Andrea - Ravenna, Ospedale S. Eugenio - Roma,
Ospedale Pert in i - Roma, Pol ic l in ico - Mi lano, Pol ic l in ico S. Matteo - Pavia, Pol ic l in ico S. Orsola - Bologna,
Radium Hospita let - Oslo, Rome American Hospita l - Roma, Ospedal i Civ i l i - Brescia, St. El izabeth Hospita l
- Uccle, US Hospita l - L inkoping.
REFERENCE
14 RC GROUP SpA • C_GNR_0507
liquid chillers / heat pumps / condenserless chillers with IDROCOMPL® system
horizontal close control air conditioners
close control air conditioners / heat pumps
close control air conditioners with displacement air delivery
CONSOLE 15
PEGASUS 19
neXt 25
COMPACT 31
roof top air conditioners
ROOF.TOP 39
FCR / FCT • SPRING • SKY.WATER 43
fan coils
close control air conditioners for TLC with free-cooling system
air cooled liquid chillers / heat pumps
water cooled liquid chillers / heat pumps / condenserless chillers
air cooled condensers / dry coolers
water cooled absorption chillers
thermal storage systems
microprocessor controls
HEAT.HUNTER 35
ENERGY.SPLIT 49
MINIPAC 53
ENERTEL 57
CILLI • CILLI.P • AQUA • DIVI 61
EASY/R 69
EASY 73
UNICO 79
GLIDER 87
REVERSO 93
air cooled liquid chillers with free-cooling system
MAXIMO 101
COLDPACK 123
FRIGO 129
TEAM.MATE 137
THERMOFRIGO 143
ICE.BANK 147
MP99 • MICROCHILLER • MP.COMxs • MP2000.GRAPHIC • MP.COM 151
index
air cooled multifunction chillers
MULTIPLO 111
TRILOGY 117
15RC GROUP SpA • C_GNR_0507
CONSOLE_horizontal close control air conditioners
cooling capacity •compressors • scrollrefrigerant •fan type • centrifugalmicroprocessor •models • 18
16 RC GROUP SpA • C_GNR_0507
CONSOLEhorizontal close control air conditioners
GENERAL FEATURES
Designed for under window installations, the CON-SOLE air conditioners are versatile and quick toinstall units.
-
The CONSOLE range is the best answer to the
Hi-Tech offices, shopping centres, museums and in-
lentness are a must.
CONSOLE.OVER
CONSOLE air conditioners are available in Over andUnder versions.
Up-flow air delivery (Over)
in to the room.The air flow in each area is predetermined duringthe design stage and it is not dependent on the ac-
plants having a defined low/medium room thermal
Down flow air delivery (Under)
the plenum between the building floor and the raisedfloor.
conditioning and it is most favourable when load is
VERSIONS :
DXA
Cooling capacity 6,6 ÷ 16,3 kW
Direct expansion air conditioner in Under and Over
versions, for remote air cooled condenser matching.
DXW
Cooling capacity 6,9 ÷ 17 kW
Direct expansion air conditioner in Under and Over
versions with built-in water cooled condenser.
CW
Cooling capacity 5,4 ÷ 20,3 kW
Chilled water feeding air conditioner in Under and
Over versions.
17RC GROUP SpA • C_GNR_0507
CONSOLEhorizontal close control air conditioners
MAIN COMPONENTS
frame. Base and panels in galvanized steel
motor.
• Electrical box in separate compartment
• Main switch
Technical compartment separated from the air flow.Compressor, electric board, humidifier and
-nical compartment separated from the air flowto allow standard maintenance with the unit inoperation.
MAIN OPTIONAL ACCESSORIES• Serial port
18 RC GROUP SpA • C_GNR_0507
CONSOLE
ab
c
horizontal close control air conditioners
CONSOLE.DXA under
MODEL
Air flow m3/hCompressors n.Weight kg
7 13 17Z1 Z1 Z1
1 1 1
TECHNICAL DATA AND NOMINAL PERFORMANCES
CONSOLE.DXW under
MODEL
Air flow m3/hCompressors n.Weight kg
7 13 17Z1 Z1 Z1
1 1 1
CONSOLE.CW under
MODEL
Air flow m3/hWeight kg
7 14 21
DIMENSIONS (mm)
Size a b c c DX CW Over Under
7 7
13 14
17 21
CONSOLE.DXA over
MODEL
Air flow m3/hCompressors n.Weight kg
7 13 17Z1 Z1 Z1
1 1 1
CONSOLE.DXW over
MODEL
Air flow m3/hCompressors n.Weight kg
7 13 17Z1 Z1 Z1
1 1 1
CONSOLE.CW over
MODEL
Air flow m3/hWeight kg
7 14 21
19RC GROUP SpA • C_GNR_0507
PEGASUS_close control air conditioners / heat pumps
cooling capacity •heating capacity •compressors • scrollrefrigerant •fan type • centrifugalmicroprocessor •free-cooling •models •
20 RC GROUP SpA • C_GNR_0507
PEGASUS
GENERAL FEATURESThe PEGASUS air conditioners form a range of ma-chines featuring advanced hi-tech characteristics,
requirements in terms of control of internal environ-
-
range of accessories, the PEGASUS units representthe most suitable solution for Hi-Tech applications
-
atmosphere rooms (museums, libraries and archi-
PEGASUS.UNDER
VERSIONS:
DXA
Cooling capacity 6,1 ÷ 92,6 kW
Direct expansion air conditioner in Under and
Over versions, for remote air cooled condenser
matching,
DXA.P
Cooling capacity 6,5 ÷ 90,2 kW
Heating capacity 5,9 ÷ 86,8 kW
Heatpumpair conditioner inOver versions, for remote
air cooled condenser matching,
DXW
Cooling capacity 6,3 ÷ 94,7 kW
Direct expansion air conditioner in Under and Over
versions, with built-in water cooled condenser
DXW.P
Cooling capacity 6,8 ÷ 40,7 kW
Heating capacity 6,5 ÷ 39,1 kW
Heat pump air conditioner in Over versions, with
built-in water cooled condenser.
CW
Cooling capacity 5,7 ÷ 104,9 kW
Chilled water feeding air conditioner in Under and
Over versions.
close control air conditioners / heat pumps
21RC GROUP SpA • C_GNR_0507
PEGASUS
PEGASUS air conditioners are available in Over andUnder version. Heat pumps are available in Over
Upflow air delivery (Over)
in to the room.The air flow in each area is predetermined duringthe design stage and it is not dependent on the ac-
plants having a defined low/medium room thermal
Downflow air delivery (Under)
the plenum between the building floor and the raisedfloor.
conditioning and it is most favourable when load is
PEGASUS.OVER
MAIN COMPONENTS
frame. Base and panels in galvanized steel
motor.
• Electrical box in separate compartment
close control air conditioners / heat pumps
MAIN OPTIONAL ACCESSORIES• Serial port
• Compressor cap for noise reduction
22 RC GROUP SpA • C_GNR_0507
PEGASUSclose control air conditioners / heat pumps
30 36 40 52 60 74 88Z2 Z2 Z2 Z2 Z2 Z2 Z2
PEGASUS.DXA.P over - heat pump
MODEL
Size
Air flow m3/hCompressors n.Weight kg
MODEL
Size
Air flow m3/hCompressors n.Weight kg
5(*) 7(*) 10 15 18 20 24 Z1 Z1 Z1 Z1 Z1 Z1 Z2
PEGASUS.DXA under/over
MODEL
Size
Air flow m3/hCompressors n.Weight kgSound pressure
20 24 30 36 30 40 40 52 52 60 74 88 60 74 88Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2
MODEL
Size
Air flow m3/hCompressors n.Weight kgSound pressure
5(*) 7(*) 10 10 15 10 18 15 15 15 20 18 24 30Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2
TECHNICAL DATA AND NOMINAL PERFORMANCES
23RC GROUP SpA • C_GNR_0507
PEGASUSclose control air conditioners / heat pumps
5(*) 7(*) 10 15 18 20 24 30 36 Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2
20 24 30 36 30 40 40 52 52 60 74 88 60 74 88Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2
5(*) 7(*) 10 10 15 10 18 15 15 15 20 18 24 30Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2
PEGASUS.DXW.P over - heat pump
MODEL
Size
Air flow m3/hCompressors n.Weight kg
PEGASUS.DXW under/over
MODEL
Size
Air flow m3/hCompressors n.Weight kgSound pressure
MODEL
Size
Air flow m3/hCompressors n.Weight kgSound pressure
TECHNICAL DATA AND NOMINAL PERFORMANCES
24 RC GROUP SpA • C_GNR_0507
PEGASUS
ab
c
close control air conditioners / heat pumps
PEGASUS.CW under/over
MODEL
Size
Air flow m3/hWeight kgSound pressure
34 44 58 71 100 109
MODEL
Size
Air flow m3/hWeight kgSound pressure
6(*) 13 16 20 21 25 26
TECHNICAL DATA AND NOMINAL PERFORMANCES
DIMENSIONS (mm)
Size a b c
S0
S1
S2
S3S
S3
S4
S5
S6
S7
S8
S9
S10
25RC GROUP SpA • C_GNR_0507
neXt_
cooling capacity •heating capacitycompressors • scrollrefrigerant •fan type • plug-fanmicroprocessor • MP.COMfree-cooling •models •
close control air conditioners / heat pumps
26 RC GROUP SpA • C_GNR_0507
neXt
CARATTERISTICHE GENERALI
The neXt series air conditioners are the best answer-
sophisticated Hi-Tech installations and in the high
environment for electronic equipment to work in andoperators wealth.
Computer rooms, telephone exchanges, internet
neXt units, whose effi--
HIGH DENSITY
and accessories, the neXt air conditioners can grant
60 kW per square meter.
VERSIONS:
DX
Cooling capacity 6,7 ÷ 97,0 kW
Direct expansion air conditioner in Under
and Over versions, for remote air cooled
condenser matching.
DX.P
Cooling capacity 7,2 ÷ 102,1 kW
Heating capacity 5,5 ÷ 90,4 kW
Heat pump air conditioner in Over versions, for remote
air cooled condenser matching.
DW
Cooling capacity 7,0 ÷ 104,1 kW
Direct expansion air conditioner in Under and Over
versions, with built-in water cooled condenser.
DW.P
Cooling capacity 7,5 ÷ 112,0 kW
Heating capacity 6,3 ÷ 110,2 kW
Heat pump air conditioner in Over versions, with
built-in water cooled condenser.
CW.S
Cooling capacity 10,3 ÷ 104,4 kW
Chilled water feeding air conditioner in Under and
Over versions.
CW.K
Cooling capacity 13,1 ÷ 160,7 kW
Chilled water feeding air conditioner in Under and
close control air conditioners / heat pumps
27RC GROUP SpA • C_GNR_0507
neXt
MAIN COMPONENTS
• Electrical box in separate compartment
• MP.COM microprocessor control
close control air conditioners / heat pumps
neXt air conditioners are available in Over andUnder version. Heat pumps are available in Over
Up-flow air delivery (Over)The air distribution is from the top of the unit di-
The air flow in each area is predetermined duringthe design stage and it is not dependent on the ac-
plants having a defined low/medium room thermal
Down-flow air delivery (Under)
the plenum between the building floor and the rai-sed floor.
conditioning and it is most favourable when load is
MAIN OPTIONAL ACCESSORIES• Serial port
• Compressor cap for noise reduction
28 RC GROUP SpA • C_GNR_0507
neXtclose control air conditioners / heat pumps
TECHNICAL DATA AND NOMINAL PERFORMANCES
neXt.DX under/over
neXt.DX.P over - heat pump
MODEL
Size
Air flow m3/hCompressors n.Weight kg
026 032 045 049 042 048 052 060 072 082 092 100Z2 Z2 Z1 Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2
MODEL
Size
Air flow m3/hCompressors n.Weight kg
007 009 011 013 015 017 021 023 025 029 033Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1
1 1 1 1 1 1 1 1 1 1 1
MODEL
Size
Air flow m3/hCompressors n.Weight kgSound pressure
026 032 045 049 042 048 052 060 072 082 092 100Z2 Z2 Z1 Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2H5 H5 H5 H5 H6 H6 H6 H6 H7 H7 H7 H7
MODEL
Size
Air flow m3/hCompressors n.Weight kgSound pressure
007 009 011 013 015 017 021 023 025 029 033Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1H1 H1 H1 H1 H2 H2 H3 H3 H4 H4 H4
1 1 1 1 1 1 1 1 1 1 1
29RC GROUP SpA • C_GNR_0507
neXtclose control air conditioners / heat pumps
TECHNICAL DATA AND NOMINAL PERFORMANCES
neXt.DW under/over
neXt.DW.P over - heat pump
MODEL
Size
Air flow m3/hCompressors n.Weight kg
026 032 045 049 042 048 052 060 072 082 092 100Z2 Z2 Z1 Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2
MODEL
Size
Air flow m3/hCompressors n.Weight kg
007 009 011 013 015 017 021 023 025 029 033Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1
1 1 1 1 1 1 1 1 1 1 1
MODEL
Size
Air flow m3/hCompressors n.Weight kgSound pressure
026 032 045 049 042 048 052 060 072 082 092 100Z2 Z2 Z1 Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2
MODEL
Size
Air flow m3/hCompressors n.Weight kgSound pressure
007 009 011 013 015 017 021 023 025 029 033Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1
1 1 1 1 1 1 1 1 1 1 1
30 RC GROUP SpA • C_GNR_0507
a b
c
neXt
neXt.CW under/over
MODEL
Size
Air flow m3/hWeight kgSound pressure
012 015 022 031 044 066 078 094 114
neXt.CW.K under/over
MODEL
Size
Air flow m3/hWeight kgSound pressure
013 020 029 046 068 104 120 142 174
DIMENSIONS (mm)
Size a b c
H1 650 650 1.925
H2 785 650 1.925
H3 1.085 750 1.925
H4 1.320 860 1.980
H5 1.620 860 1.980
H6 2.155 860 1.980
H7 2.690 860 1.980
H8 3.225 860 1.980
close control air conditioners / heat pumps
TECHNICAL DATA AND NOMINAL PERFORMANCES
31RC GROUP SpA • C_GNR_0507
COMPACT_close control air conditioners
cooling capacity •feeding • chilled waterfan type • centrifugalmicroprocessor •models •
32 RC GROUP SpA • C_GNR_0507
COMPACTclose control air conditioners with high cooling density
GENERAL FEATURES
The units of the COMPACT series are chilled water airconditioners, coming from the PEGASUS series.
requirements of the modern and sophisticated Hi-Tech-
formances, also in complex logistic situations, where
operate..
HIGH DENSITY
and accessories, the COMPACT air conditioners
54 kW per square meter.
COMPACT.UNDER
COMPACT are available in Over and Under version.
Up-flow air delivery (Over)
in to the room.The air flow in each area is predetermined duringthe design stage and it is not dependent on the ac-
plants having a defined low/medium room thermal
Down-flow air delivery (Under)
the plenum between the building floor and the raisedfloor.
conditioning and it is most favourable when load is
VERSION:
CW
Cooling capacity 40,6 ÷ 161,3 kW
Chilled water feeding air conditioner in Under and
33RC GROUP SpA • C_GNR_0507
COMPACTclose control air conditioners with high cooling density
COMPACT.OVER
MAIN COMPONENTS
profile frame. Base and panels in
with PVC film.
• Electrical box in separate compartment
MAIN OPTIONAL ACCESSORIES
• Serial port
• Plenum on air suction
• Floor stand
OVER VERSION
version foresees the room air intake from theunit bottom.This characteristic allows the unit installationin room with raised floor, that makes possiblethe air intake.In case the unit is installed in plant withoutraised floors, a support frame lifting the unitfrom the floor or a plenun equipped withgrilles on 3 sides are available as optionalaccessories.
34 RC GROUP SpA • C_GNR_0507
COMPACT
ab
c
close control air conditioners with high cooling density
COMPACT.CW under/over
MODEL
Size
Air flow m3/hWeight kg
42 71 92 110 116 138 166
TECHNICAL DATA AND NOMINAL PERFORMANCES
DIMENSIONS (mm)
Size a b c c1
G0
G1
G2
G2S
G3
G3S
G4 (Over)
G4 (Under)
35RC GROUP SpA • C_GNR_0507
HEAT.HUNTER_close control air conditioners
cooling capacity •compressors • scrollrefrigerant •fan type • centrifugalmicroprocessor • MP.COMfree-coolingmodels • 18
36 RC GROUP SpA • C_GNR_0507
HEAT.HUNTERclose control air conditioners with displacement air delivery
GENERAL FEATURES
The HEAT HUNTER air conditioners, with displa-cement air distribution, are the air conditioningspearhead solution for telephone exchanges, inter-net hotels applications and electronic applianceshigh concentration rooms, for the electric consump-tion optimisation in these specific ambients.
the air distribution.
HEAT HUNTER, in combination with RC GroupFree-Cooling chillers, forms the SOLUTION® paten-
-sence of Hi-Tech plants with variable flow.
Displacement air delivery (DL)
-
the equipment installed in the room, and can rea-ch also the equipment located in critical positions,thanks to patented AIR-RAIL®
of cold required to maintain a correct temperaturelevel inside, through a natural convection effect. Thegreater the load inside the electronic equipment, thegreater this effect.
amount required to dissipate its own thermal load,
VERSIONS :
DX
Cooling capacity 8,4 ÷ 49,5 kW
Direct expansion air conditioner, for remote air
cooled condenser matching.
DW
Cooling capacity 8,8 ÷ 52,6 kW
Direct expansion air conditioner, with built-in water
cooled condenser.
CW
Cooling capacity 14,5 ÷ 66,1 kW
Chilled water feeding air conditioner.
HEAT.HUNTER
37RC GROUP SpA • C_GNR_0507
HEAT.HUNTERclose control air conditioners with displacement air delivery
MAIN COMPONENTS
profile frame and panels in galvanized steel
• Electrical box in separate compartment
• MP.COM microprocessor control
HEAT.HUNTER
MAIN OPTIONAL ACCESSORIES• Serial port
• Condensate discharge pump
• Plenum on air suction for direct free-cooling
AIR-RAIL® System
positioning.
MISTRAL® control logicThe real displacement motor is the difference in air
must remain constant under all operating conditions.The MISTRAL® (Modulating control of Indoor STRA-
and the power of the heat exchange unit are varied.The MISTRAL®
38 RC GROUP SpA • C_GNR_0507
HEAT.HUNTER
a b
c
close control air conditioners with displacement air delivery
HEAT.HUNTER.DXMODEL
Size
3/hCompressors n.Weight kg
007 009 010 013 015 016 020 023 026 030 037 045Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1
1 1 1 1 1 1 1 1 1 1 1 1
TECHNICAL DATA AND NOMINAL PERFORMANCES
HEAT.HUNTER.DWMODEL
Size
3/hCompressors n.Weight kg
007 009 010 013 015 016 020 023 026 030 037 045Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1
1 1 1 1 1 1 1 1 1 1 1 1
HEAT.HUNTER.CWMODEL
Size
3/hWeight kg
14 21 25 44 63
DIMENSIONS (mm)
Size a b c
HH0
HH1
HH2
HH3
39RC GROUP SpA • C_GNR_0507
ROOF.TOP_packaged air conditioners and heat pumps
cooling capacity •heating capacity •compressors • scrollrefrigerant •fan type • centrifugalmicroprocessor •models •
40 RC GROUP SpA • C_GNR_0507
ROOF.TOP
GENERAL FEATURES
The ROOF-TOP series air conditioners are suitablefor civil and industrial installations, where the units
-mental requirements.
The units are realised with atmospheric-proof mate-rials, making them suitable for outdoor installation.The wide range of available optional accessories is
ROOF.TOP.RE -
-ble, with no more need of the traditional wall supp-
Horizontal air delivery
The air flow in each area is predetermined during thedesign stage and it is not dependent on the actual
production facilities and in all those applicationswhere air conditioning for operators wealth is requi-red.
bottom.
VERSIONS :
DX
Cooling capacity 53,4 ÷ 225,5 kW
Packaged direct expansion air conditioner with
built-in air cooled condenser.
DX.P
Cooling capacity 53,4 ÷ 225,5 kW
Heating capacity 54,7 ÷ 233,4 kW
Packaged heat pump air conditioner with built-in
air cooled condenser.
ROOF.TOP
41RC GROUP SpA • C_GNR_0507
ROOF.TOP
MAIN COMPONENTS
sheet
thickness sandwich panels in galvanized steel
• Scroll compressor
• Electrical box in separate compartment
ROOF.TOP
MAIN OPTIONAL ACCESSORIES• Serial port
control, for installation in ambient with high
crowding.
• Roof-curb: counter-frame for unit installation.
It avoids the construction of the traditional
support wall
• Humidifier
IDEA® defrosting systemROOF.TOP.HP version
-tware it senses the real presence of brine on the
-
42 RC GROUP SpA • C_GNR_0507
ROOF.TOP
ba
c
ROOF.TOP.DXMODEL
Air handling Air flow m3/h
Air flow m3/hCompressors n.Weight kg
51 61 81 91 111 122 142 162 192 222Z2.ST Z2.ST Z2.ST Z2.ST Z2.ST Z4.ST Z4.ST Z4.ST Z4.ST Z4.ST
TECHNICAL DATA AND NOMINAL PERFORMANCES
DIMENSIONS (mm)
Model a b c
51
61
81 - 91
111
122 - 142 - 162
192 - 222
ROOF.TOP.DX.PMODEL
Air handling Air flow m3/h
Air flow m3/hCompressors n.Weight kg
51 61 81 91 111 122 142 162 192 222Z2.ST Z2.ST Z2.ST Z2.ST Z2.ST Z4.ST Z4.ST Z4.ST Z4.ST Z4.ST
43RC GROUP SpA • C_GNR_0507
FAN.COILS_
cooling capacity •feeding • chilled waterfan type • centrifugal / tangentialmodels •
44 RC GROUP SpA • C_GNR_0507
FAN.COILS
GENERAL FEATURES
The FAN COILS series is offering a simple, eco-nomic and versatile solution for the climatization ofapartments and offices.The proposed models, together with a wide range of
-
reduction.All versions are equipped with multi-speed fans and,
VERSIONS :
FCR
Cooling capacity 0,8 ÷ 11,0 kW
ceiling or recessed installation.
FCT
Cooling capacity 1,0 ÷ 3,88 kW
ceiling or recessed installation.
SKY.WATER
Cooling capacity 1,9 ÷ 10,5 kW
Cassette equipped with centrifugal fan for false-
ceiling installatio.
SPRING
Cooling capacity 2,0 ÷ 4,4 kW
Fan coil equipped with centrifugal fan for wall
mounting installation.
MAIN COMPONENTS
FCR / FCT• Housing in galvanized steel sheet. Cabinet in
• Integrated control panel
6 speed electric motor
speed electric motor
MAIN OPTIONAL ACCESSORIES• Multifunction remote control
• Electronic thermostat
• Electric heater
• Control valves
• Panels for recessed version
FCR / FCT
45RC GROUP SpA • C_GNR_0507
FAN.COILS
SKY.WATER
SPRING
MAIN COMPONENTS
SKY.WATER• Housing in galvanized steel sheet and frontal
panel in plastic material.
suction ducting.
• Integrated control panel
electric motor
• Condensate discharge pump
• Multifunction remote control
MAIN OPTIONAL ACCESSORIES• Control valves
• Remote control panel
MAIN COMPONENTS
SPRING• Housing in galvanized steel sheet and frontal
panel in plastic material.
• Integrated control panel
electric motor
• Multifunction remote control
MAIN OPTIONAL ACCESSORIES• Control valves
46 RC GROUP SpA • C_GNR_0507
FAN.COILS
a
b
c
TECHNICAL DATA AND NOMINAL PERFORMANCES
FCRMODEL
Air flow max m3/h mid m3/h min m3/h
Weight kg
10 20 30 40 50 60 70 80 90 100 110 120
DIMENSIONS (mm)
Model a b c
10
20
30 - 40
50 - 60
70
80 - 90
100
110 - 120
47RC GROUP SpA • C_GNR_0507
FAN.COILS
a
b
c
FCTMODEL
Air flow max m3/h mid m3/h min m3/h
Weight kg
10 20 30 40 60
TECHNICAL DATA AND NOMINAL PERFORMANCES
DIMENSIONS (mm)
Model a b c
10
20
30
40
60
48 RC GROUP SpA • C_GNR_0507
FAN.COILS
a
b
c
a
c
b
DIMENSIONS (mm)
Model a b c
100
200
300
SPRINGMODEL
Air flow max m3/h mid m3/h min m3/h
Weight kg
100 200 300
SKY.WATERMODEL
Air flow max m3/h mid m3/h min m3/h
Weight kg
10 20 30 40 43 45 50 60
TECHNICAL DATA AND NOMINAL PERFORMANCES
DIMENSIONS (mm)
Model a b c
10 - 20 - 30 - 40
43 - 45 - 50 - 60
TECHNICAL DATA AND NOMINAL PERFORMANCES
49RC GROUP SpA • C_GNR_0507
ENERGY.SPLIT_
cooling capacity •compressors •refrigerant •fan type • centrifugalmicroprocessor • MP.COM.xsdirect free-coolingmodels • 8
for telecommunication facilities
50 RC GROUP SpA • C_GNR_0507
ENERGY.SPLIT
VERSIONS :
DX
Cooling capacity 4,1 ÷ 14,2 kW
-
split-system air conditioners with free-cooling system, for telecommunication facilities
GENERAL FEATURES
The air conditioners of the ENERGY-SPLIT seriesare suitable for installation in small telephone roomsand shelters for mobile telecommunications
The proportional free-cooling system
equipped with a proportional automatic free-cooling-
door temperature is higher than outdoor one.
order to cool the ambient, when the outside condi-tions allow it.
three working modes:
ambient;- partial free-cooling: the fresh air is used for a pre-
cooling and the compressor or the chilled waterare used to balance the load;
- mechanical cooling: the compressor or the chilledwater are used to cool the ambient
ENERGY.SPLIT
The ENERGY-SPLIT evaporating unit can be instal-led on a wall with vertical air flow, or on ceiling withhorizontal air flow.
Horizontal or vertical air flow
in to the room.-
re but at high speed in correspondence to the corri-dors between the different racks rows. The cold airmoves from the top to the bottom with a turbulentflow, mixing with the hot air outgoing from the racks.
51RC GROUP SpA • C_GNR_0507
ENERGY.SPLITsplit-system air conditioners with free-cooling system, for telecommunication facilities
ENERGY.SPLIT
MAIN COMPONENTS
CONDENSING UNIT (outdoor)
sheet.
• Electrical box in separate compartment
EVAPORATING UNIT (indoor)
sheet
electric motor
• Electrical box in separate compartment
• MP.COMxs microprocessor control
MAIN OPTIONAL ACCESSORIES
• serial port
• remote control panel
• electric heater
Direct free-cooling system
dramatic reduction of the compressor workinghours and electrical consumption.
Double power supply
even during black-out periods.
Nocturne working mode
the lowest noise emission during the night.
52 RC GROUP SpA • C_GNR_0507
ENERGY.SPLIT
a b
c
c
a
b
split-system air conditioners with free-cooling system, for telecommunication facilities
ENERGY.SPLIT.DX.A evaporating unit
MODEL
Size
Air flow m3/hWeight kg
4 5 6 7 8 10 13 15Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1
TECHNICAL DATA AND NOMINAL PERFORMANCES
ENERGY.SPLIT.DX.A condensing unit
DIMENSIONS (mm)
EVAPORATING UNIT (INDOOR)
Size a b c
S0
S1
S2
CONDENSING UNIT (OUTDOOR)
Size a b c
4.R1 ÷ 5.R1
6.Z1 ÷ 8.Z1
10.Z1 ÷ 15.Z1
MODELLO
Compressors n.Weight kg
4 5 6 7 8 10 13 15Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1
1 1 1 1 1 1 1 1
53RC GROUP SpA • C_GNR_0507
MINIPAC_
cooling capacity •compressors • /scrollrefrigerant •fan type • axial/centrifugalmicroprocessor • MP.COM.xsdirect free-coolingmodels • 8
packaged air conditioners for outdoor installation
54 RC GROUP SpA • C_GNR_0507
MINIPACpackaged air conditioners for outdoor installation with free-cooling system for telecommunication facilities
GENERAL FEATURES
for small telephone rooms and shelters for mobile te-lecommunications.Packaged units, suitable for outdoor installation,
UPS.
The proportional Free-Cooling system
equipped with a proportional automatic free-cooling-
door temperature is higher than outdoor one.
order to cool the ambient, when the outside condi-tions allow it.
three working modes:
ambient;- partial free-cooling: the fresh air is used for a pre-
cooling and the compressor or the chilled waterare used to balance the load;
- mechanical cooling: the compressor or the chilledwater are used to cool the ambient
MINIPAC
VERSIONS :
DX
Cooling capacity 4,2 ÷ 19,4 kW
Packaged air conditioners with direct free-cooling
55RC GROUP SpA • C_GNR_0507
MINIPACpackaged air conditioners for outdoor installation with free-cooling system for telecommunication facilities
MAIN COMPONENTS
galvanized steel sheet.
• Electrical box in separate compartment
• MP.COMxs microprocessor control
MINIPAC
MAIN OPTIONAL ACCESSORIES• Serial port
• Remote control panel
• Electric heater
• Wall mounting brackets
MINIPAC air conditioners are available in Over
Upflow air delivery (Over)The air distribution is from the top of the unit
-rature but at high speed in correspondence tothe corridors between the different racks rows.The cold air moves from the top to the bottomwith a turbulent flow, mixing with the hot airoutgoing from the racks.
Double power supply
even during black-out periods.
Nocturne working mode
the lowest noise emission during the night.
56 RC GROUP SpA • C_GNR_0507
a b
c
MINIPAC
MINIPAC.DX.A over
MODEL
Size
Air flow m3/hCompressors n.Weight kg
4 5 6 8 9 11 13 16 20R1 R1 Z1 Z1 Z1 Z1 Z1 Z1 Z1
1 1 1 1 1 1 1 1 1
TECHNICAL DATA AND NOMINAL PERFORMANCES
DIMENSIONS (mm)
Size a b c
S0
S1
S1S
S2
S3
packaged air conditioners for outdoor installation with free-cooling system for telecommunication facilities
57RC GROUP SpA • C_GNR_0507
ENERTEL_
cooling capacity •compressors • scrollrefrigerant •fan type • centrifugalmicroprocessore • MP.COM.xsdirect free-coolingmodels •
for telecommunication facilities
58 RC GROUP SpA • C_GNR_0507
ENERTELpackaged air conditioners with free-cooling system for telecommunication facilities
GENERAL FEATURES
The ENERTEL air conditioners are suitable for smalltelephone rooms and shelters for mobile telecom-munications. Packaged units, equipped with double
The proportional free-cooling system
equipped with a proportional automatic free-cooling-
door temperature is higher than outdoor one.
order to cool the ambient, when the outside condi-tions allow it.
three working modes:
ambient;- partial free-cooling: the fresh air is used for a pre-
cooling and the compressor or the chilled waterare used to balance the load;
- mechanical cooling: the compressor or the chilledwater are used to cool the ambient
ENERTEL.DL
VERSIONS :
DX.A.O
Cooling capacity 5,2 ÷ 14,6 kW
Packaged air conditioners with direct free-coo-
DX.A.DL / DX.A.U
Cooling capacity 6,7 ÷ 15,5 kW
Packaged air conditioners with direct free-coo-
Double power supply
black-out periods.
Nocturne working mode
lowest noise emission during the night.
ENERTEL.U
59RC GROUP SpA • C_GNR_0507
ENERTELpackaged air conditioners with free-cooling system for telecommunication facilities
ENERTEL.O
MAIN COMPONENTS
• Housing in anodised aluminium profile
frame. Base and panels in galvanized steel
• Scroll compressor
• Electrical box in separate compartment
• MP.COMxs microprocessor control
MAIN OPTIONAL ACCESSORIES
• Serial port
• Remote control panel
• Electric heater
• Fresh air suction kit
ENERTEL air conditioners are available in Over, Underand Displacement versions.
Upflow air delivery (Over)
to the room.
but at high speed in correspondence to the corridorsbetween the different racks rows. The cold air movesfrom the top to the bottom with a turbulent flow, mixingwith the hot air outgoing from the racks.
Downflow air delivery (Under)
plenum between the building floor and the raised floor.-
ditioning and it is most favourable when load is uniform-
Displacement air delivery (DL)-
convection.
at the floor level which is available for all the equipmentinstalled in the room, and can reach also the equipmentlocated in critical positions.
60 RC GROUP SpA • C_GNR_0507
ab
c
ENERTEL
ENERTEL.DX.A over
TECHNICAL DATA AND NOMINAL PERFORMANCES
ENERTEL.DX.A displacement / under
DIMENSIONS (mm)
E N E R T E L . O
Size a b c
S1
S2
S3
MODEL
Size
Air flow m3/hCompressors n.Weight kg
5 6 7 8 10 11 13 15Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1
1 1 1 1 1 1 1 1
POWER SUPPLY:
MODEL
Size
Air flow m3/hCompressors n.Weight kg
6 7 8 9 10 13 15Q1 Q1 Q1 Q1 Q1 Q1 Q1
1 1 1 1 1 1 1
E N E R T E L . D L / E N E R T E L . U
Size a b c
S1
S2
S3
packaged air conditioners with free-cooling system for telecommunication facilities
61RC GROUP SpA • C_GNR_0507
IDROCOMPL®_
cooling capacity • 5,2 ÷ 41,5 kWheating capacity • 7,2 ÷ 60,2 kWcompressors • scrollrefrigerant • R407Cfan type • axial/centrifugalmicroprocessor • MICROCHILLERmodels • 30
liquid chillers, condenserless chillers, heat pump with Idrocompl® system
62 RC GROUP SpA • C_GNR_0507
IDROCOMPL®
liquid chillers, condenserless chillers, heat pump with Idrocompl® system
GENERAL FEATURES
The IDROCOMPL® range of units includes three diffe-rent units types, manufactured with the same system, for domestic and small offices climatization.
VERSIONS:
CILLI.A (R407C)
Cooling capacity 6,2 ÷ 52,1 kW
Liquid chiller equipped with scroll compressor and
axial fan.
CILLI.A.P (R407C)
Cooling capacity 6,1 ÷ 52,1 kW
Heating capacity 7,3 ÷ 59,6 kW
Heat pump liquid chiller equipped with scroll com-
pressor and axial fan.
CILLI.C (R407C)
Cooling capacity 6,2 ÷ 52,1 kW
Liquid chiller equipped with scroll compressor and
centrifugal fan.
CILLI.C.P (R407C)
Cooling capacity 6,0 ÷ 50,3 kW
Heating capacity 7,2 ÷ 59,6 kW
Heat pump liquid chiller equipped with scroll com-
pressor and centrifugal fan.
AQUA (R407C)
Cooling capacity 6,6 ÷ 59,9 kW
Liquid chiller equipped with scroll compressor and
built-in water cooled condenser.
DIVI (R407C)
Cooling capacity 6,1 ÷ 52,7 kW
Condenserless liquid chiller equipped with scroll
compressor.
DIVI.P (R407C)
Cooling capacity 6,0 ÷ 51,6 kW
Heating capacity 7,2 ÷ 60,2 kW
Condenserless heat pump liquid chiller equipped
with scroll compressor.
CILLI
AQUA
DIVI
63RC GROUP SpA • C_GNR_0507
IDROCOMPL®
9
8
7
6
55
13
12
11
10
2 31 2 4
liquid chillers, condenserless chillers, heat pump with Idrocompl® system
THE IDROCOMPL® SYSTEM
IDROCOMPL® system including the following components:
- gas/water heat exchanger- expansion tank - water tank
with the following functions:• thermal storage to avoid compressor “short cycle”• absorption of hydraulic expansion with expansion tank• heat exchanger• stray electrical current protection by magnesium anode
COMPONENTS
1) Water outlet
2) Cooling circuits
3) Magnesium anode
4) Breather valve
5) Temperature sensors
6) Water pump (optional)
7) Safety valve
8) Water inlet
9) Discharge tap
10) Water tank
11) Expansion tank
12) Anticondensate insulation
13) Gas/water heat exchanger
IDROCOMPL® SYSTEM
IDROCOMPL® system is not afraid of ice formation, thanks to its own exchanger made with an external sheet realized into elastic material. This main feature does not allow any cracking for freezing and avoids damage to the cooling circuit.
64 RC GROUP SpA • C_GNR_0507
IDROCOMPL®
CILLI.A.D2
MAIN COMPONENTS CILLI.D2
• Housing in epoxy painted galvanized steel
sheet
• Scroll compressor
• CILLI.A: Axial fan with safety mesh
• CILLI.C Single suction centrifugal fan
• IDROCOMPL® system
• Microprocessor control
• Modulating condensing control
• Electrical box in separate compartment
• Main switch
• Cycle reversing valve (CILLI.P)
• Defrosting system (CILLI.P)
CILLI.C.D2
CILLI.A.D3/D4
CILLI.C.D3/D4
MAIN COMPONENTS CILLI.D3/D4
• Housing in anodised aluminium profile
frame. Base and panels in galvanized steel
sheet externally coated with PVC film.
• Scroll compressor
• CILLI.A: Axial fan with safety mesh
• CILLI.C: Double suction centrifugal fan
• IDROCOMPL® system
• Microprocessor control
• Modulating condensing control
• Electrical box in separate compartment
• Main switch with door lock safety
• Cycle reversing valve (CILLI.P)
• Defrosting system (CILLI.P)
MAIN OPTIONAL ACCESSORIES
• Serial port
• Remote control panel
• Circulating pump
• Horizontal air discharge (CILLI.C)
MAIN OPTIONAL ACCESSORIES
• Serial port
• Remote control panel
• Circulating pump
• Horizontal air discharge (CILLI.C)
liquid chillers, condenserless chillers, heat pump with Idrocompl® system
65RC GROUP SpA • C_GNR_0507
IDROCOMPL®
AQUA.D1
DIVI.D2 / D3
MAIN COMPONENTS AQUA
• Housing in epoxy painted galvanized steel
sheet
• Scroll compressor
• IDROCOMPL® system
• Microprocessor control
• Electrical box in separate compartment
• Main switch with door lock safety
• Built-in water cooled condenser
AQUA.D2 / D3
MAIN COMPONENTS DIVI
• Housing in epoxy painted galvanized steel
sheet
• Scroll compressor
• IDROCOMPL® system
• Microprocessor control
• Electrical box in separate compartment
• Main switch with door lock safety
• Cycle reversing valve (DIVI.P)
• Defrosting system (DIVI.P)
DIVI.D1
MAIN OPTIONAL ACCESSORIES
• Serial port
• Remote control panel
• Circulating pump
• Water regulating valve
MAIN OPTIONAL ACCESSORIES
• Serial port
• Remote control panel
• Circulating pump
• Remote air cooled condenser
liquid chillers, condenserless chillers, heat pump with Idrocompl® system
66 RC GROUP SpA • C_GNR_0507
IDROCOMPL®
TECHNICAL DATA AND NOMINAL PERFORMANCES
CILLI.A axial fan
MODEL
SizeCooling capacity (1) kW Compressors n.Power input kWGas circuits n.Weight kgSound pressure (3) dB(A)
CILLI.A.P axial fan - heat pump
MODEL
SizeCooling capacity (1) kW Cooling capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
M.7 M.8 M.9 T.8 T.9 T.13 T.16 T.19 T.24 T.28 T.34 T.38 T.42 T.50 T.58Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z12D2 D2 D2 D2 D2 D2 D2 D2 D3 D3 D3 D4 D4 D4 D46,2 7,1 8,5 7 8,4 12,9 14,8 16,3 21 24 28,3 32,5 38,3 45,5 52,11 1 1 1 1 1 1 1 2 2 2 2 2 2 2
1,9 2,4 2,7 2,3 2,7 4 4,8 5,7 6,3 8,8 10,2 11,5 11,9 15,2 17,31 1 1 1 1 1 1 1 1 1 1 1 1 1 1
135 137 145 137 145 185 195 205 375 385 425 485 620 650 65550 50 50 50 50 54 54 54 61 61 61 62 64 64 64
M.7 M.8 M.9 T.8 T.9 T.13 T.16 T.19 T.24 T.28 T.34 T.38 T.42 T.50 T.58Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z12D2 D2 D2 D2 D2 D2 D2 D2 D3 D3 D3 D4 D4 D4 D46,1 7 8,3 6,9 8,3 12,7 14,5 15,4 19,8 23,5 27,6 30,6 37,4 44 50,37,3 8,5 10,1 8,3 10 15,2 17,3 18,4 23,7 27,6 32,9 37,2 43,7 51 59,61 1 1 1 1 1 1 1 2 2 2 2 2 2 2
1,9 2,4 2,8 2,3 2,7 4 4,8 5,9 6,9 8,8 10,2 11,9 12,3 15,7 17,82,2 2,7 3,1 2,6 3 4,3 5,1 5,8 7,2 8,6 10,1 11,5 13 15,3 17,91 1 1 1 1 1 1 1 1 1 1 1 1 1 1
138 140 148 140 148 189 199 209 385 395 435 495 635 665 67050 50 50 50 50 54 54 54 61 61 61 62 64 64 64
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water outlet temperature 45°C and outdoor air temperature at 7°C
POWER SUPPLY: M = 230.1.50 T = 400.3.50+N
CILLI.C centrifugal fan
MODEL
SizeCooling capacity (1) kW Compressors n.Power input kWGas circuits n.Weight kgSound pressure (3) dB(A)
M.7 M.8 M.9 T.8 T.9 T.13 T.16 T.19 T.24 T.28 T.34 T.38 T.42 T.50 T.58Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z12D2 D2 D2 D2 D2 D2 D2 D2 D3 D3 D3 D3 D4 D4 D46,2 7,1 8,5 7 8,4 12,9 14,8 16,3 21 24 28,3 32,5 38,3 45,5 52,11 1 1 1 1 1 1 1 2 2 2 2 2 2 2
1,9 2,4 2,7 2,3 2,7 4 4,8 5,7 6,3 8,8 10,2 11,5 11,9 15,2 17,31 1 1 1 1 1 1 1 1 1 1 1 1 1 1
140 140 150 142 150 185 200 240 455 460 470 480 745 750 75558 58 58 58 58 64 64 64 66 66 66 68 69 69 69
CILLI.C.P centrifugal fan - heat pump
MODEL
SizeCooling capacity (1) kW Cooling capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
M.7 M.8 M.9 T.8 T.9 T.13 T.16 T.19 T.24 T.28 T.34 T.38 T.42 T.50 T.58Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z12D2 D2 D2 D2 D2 D2 D2 D2 D3 D3 D3 D3 D4 D4 D46 6,8 8,1 6,8 8 12,4 14 14,9 19,8 23,5 27,6 30,6 37,4 44 50,3
7,2 8,3 10 8,2 9,8 14,9 17 18,1 23,7 27,6 32,9 37,2 43,7 51 59,61 1 1 1 1 1 1 1 2 2 2 2 2 2 22 2,5 2,9 2,4 2,9 4,2 5 6,3 6,9 8,8 10,2 11,9 12,3 15,7 17,8
2,2 2,7 3,1 2,6 3 4,3 5,1 5,8 7,2 8,6 10,1 11,5 13 15,3 17,91 1 1 1 1 1 1 1 1 1 1 1 1 1 1
143 143 153 145 153 189 204 244 465 470 480 490 760 765 77058 58 58 58 58 64 64 64 66 66 66 68 69 69 69
liquid chillers, condenserless chillers, heat pump with Idrocompl® system
67RC GROUP SpA • C_GNR_0507
IDROCOMPL®
AQUA water cooled
MODEL
SizeCooling capacity (1) kW Compressors n.Power input kWGas circuits n.Weight kgSound pressure (3) dB(A)
M.7 M.8 M.9 T.8 T.9 T.13 T.16 T.19 T.24 T.28 T.34 T.38 T.42 T.50 T.58Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z12D1 D1 D1 D1 D1 D1 D1 D1 D2 D2 D2 D2 D3 D3 D36,6 7,5 9,6 7,4 9,5 13,4 15,7 18,9 23,6 27,7 33,3 36,9 41,8 50,6 59,91 1 1 1 1 1 1 1 2 2 2 2 2 2 2
1,9 2,3 2,4 2,3 2,3 4,1 4,6 4,8 5,6 7,5 8,4 10,1 11,1 13,6 14,51 1 1 1 1 1 1 1 1 1 1 1 1 1 1
125 125 125 125 125 145 150 160 265 275 300 325 482 487 50548 50 50 50 50 52 52 52 54 54 54 54 55 55 55
TECHNICAL DATA AND NOMINAL PERFORMANCES
DIVI air cooled - condenserless
MODEL
SizeCooling capacity (1) kW Compressors n.Power input kWGas circuits n.Weight kgSound pressure (3) dB(A)Remote condenserTEAM.MATE DX.A
M.7 M.8 M.9 T.8 T.9 T.13 T.16 T.19 T.24 T.28 T.34 T.38 T.42 T.50 T.58Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z12D1 D1 D1 D1 D1 D1 D1 D1 D2 D2 D2 D2 D3 D3 D36,1 7 8,9 6,9 8,8 12,7 14,8 16,5 20,4 25 28,8 33,8 37,4 46,9 52,71 1 1 1 1 1 1 1 2 2 2 2 2 2 2
1,9 2,4 2,6 2,4 2,5 4,1 4,7 5,6 6,6 8,2 10 10,7 12,6 14,3 16,91 1 1 1 1 1 1 1 1 1 1 1 1 1 1
120 120 125 120 125 135 140 155 265 275 285 295 462 485 49548 50 50 50 50 52 52 52 52 54 54 54 55 55 55
M.10 M.10 M.18 M.10 M.18 M.18 M.22 M.22 M.31 M.37 M.37 M.50 M.50 M.72 M.72
(1) Referred to chilled water temperature 12/7°C and condenser water inlet temperature 30°C
POWER SUPPLY: M = 230.1.50 T = 400.3.50+N
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C
POWER SUPPLY: M = 230.1.50 T = 400.3.50+N
DIVI.P air cooled heat pump - condenserless
MODEL
SizeCooling capacity (1) kW Cooling capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)Remote condenser TEAM.MATE DX.A
M.7 M.8 M.9 T.8 T.9 T.13 T.16 T.19 T.24 T.28 T.34 T.38 T.42 T.50 T.58Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2 Z2 Z2 Z2 Z12D1 D1 D1 D1 D1 D1 D1 D1 D2 D2 D2 D2 D3 D3 D36 6,9 8,7 6,9 8,6 12,5 14,5 16 20,1 24,4 28 32,4 37 46,2 51,6
7,2 8,3 10,7 8,2 10,5 14,9 17,3 19,2 23,8 29,2 33,4 38,7 43,6 53,8 60,21 1 1 1 1 1 1 1 2 2 2 2 2 2 2
1,9 2,4 2,6 2,4 2,5 4,1 4,7 5,6 6,6 8,2 10 10,7 12,6 14,3 172,2 2,7 3,1 2,6 3 4,3 5,1 5,8 7,2 8,8 10,1 11,6 13 15,4 17,91 1 1 1 1 1 1 1 1 1 1 1 1 1 1
123 123 128 123 128 139 144 159 275 285 295 305 477 500 51048 50 50 50 50 52 52 52 52 54 54 54 55 55 55
M.10 M.10 M.18 M.10 M.18 M.18 M.22 M.22 M.31 M.37 M.37 M.50 M.50 M.72 M.72
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water inlet temperature 40°C and outdoor air temperature 7°C
POWER SUPPLY: M = 230.1.50 T = 400.3.50+N
liquid chillers, condenserless chillers, heat pump with Idrocompl® system
68 RC GROUP SpA • C_GNR_0507
a b
c
IDROCOMPL®
ab
c
a b
c
DIMENSIONS (mm)
Size a b c
D2 1.342 497 969
D3 1.300 895 1.645
D4 2.000 895 1.645
CILLI.A
Size a b c
D2 1.342 497 969
D3 1.300 895 1.960
D4 2.000 895 1.960
CILLI.C
Size a b c
D1 667 497 969
D2 1.342 497 1.340
D3 1.608 708 1.360
AQUA - DIVI
liquid chillers, condenserless chillers, heat pump with Idrocompl® system
69RC GROUP SpA • C_GNR_0507
EASY “R”_
cooling capacity • 5,2 ÷ 41,5 kWheating capacity • 6,2 ÷ 49,5 kWcompressors • scrollrefrigerant • R407Cfan type • axialmicroprocessor • MICROCHILLERmodels • 30
air cooled liquid chillers / heat pumps
70 RC GROUP SpA • C_GNR_0507
EASY “R”
EASY.R1 / R2
air cooled liquid chillers / heat pumps
GENERAL FEATURES
The EASY.R liquid chillers offer a simple and cheap solution for domestic and small offices application.
Criticality of these smaller systems are the same as the larger installations, differing only in size Comfort requirements for a small 40m2 2/4 persons advertising office are just the same but smaller, than for an equi-valent 1000m2 / 100 persons location.
Designed for comfort applicationsThese liquid chillers grant the same reliability of the other RC Group products, being designed and manufactured with same philosophy as all RC Group products during more than 40 years activity.
Thanks to this long experience, the main repetitive fault rates and relative causes have been eliminated through the use of well tested and top quality components.Furthermore, all maintenance operations have been reduced at the minimum, since this type of chillers are now to be considered as a common home appliance, that does not require any frequent and complicated operations.
Hydronic group
VERSIONS:
EASY “R” (R407C)
Cooling capacity 5,2 ÷ 41,5 kW
Air cooled liquid chiller equipped with scroll com-
pressor and axial fan.
EASY.P “R” (R407C)
Cooling capacity 5,2 ÷ 41,1 kW
Heating capacity 6,2 ÷ 49,5 kW
Air cooled heat pump liquid chiller equipped with
scroll compressor and axial fan.
Easy and quick installation, since the units are completely factory assembled, wired and filled with refrigerant and oil and complete with all control and protection devices. They simply need electrical and hydraulic connections.
71RC GROUP SpA • C_GNR_0507
EASY “R”air cooled liquid chillers / heat pumps
MAIN COMPONENTS
• Housing in epoxy painted galvanized steel sheet
• Axial fans
• Scroll compressors
• Welded plate evaporator
•
• Modulating condensing control
• Antifreeze system
• Water flow control by differential pressure
switch
• Cycle reversing valve (EASY.P)
• Defrosting system (EASY.P)
• MICROCHILLER microprocessor control
• Electrical box in separate compartment
• Main switch
MAIN OPTIONAL ACCESSORIES
• Hydronic group
• Pumping group
• Remote control panel
• Serial port
EASY.R4
EASY.R3
72 RC GROUP SpA • C_GNR_0507
EASY “R”
a b
c
air cooled liquid chillers / heat pumps
TECHNICAL DATA AND NOMINAL PERFORMANCES
EASY “R”MODEL
SizeCooling capacity (1) kW Compressors n.Power input kWGas circuits n.Weight kgSound pressure (3) dB(A)
EASY.P “R”MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
M.5 M.6 M.8 M.9 T.8 T.9 T.11 T.14 T.16 T.18 T.20 T.24 T.28 T.35 T.43Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1R1 R1 R1 R1 R1 R1 R2 R2 R2 R2 R3 R3 R3 R4 R45,2 6,4 7,5 8,8 7,5 8,7 10,9 12,9 15,6 17,4 20,7 24,5 27,8 34,1 41,51 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1,5 2 2,6 3 2,5 2,9 3,5 4,5 5,1 6 5,9 7,6 9,1 11,3 13,61 1 1 1 1 1 1 1 1 1 1 1 1 1 180 80 82 83 82 83 105 108 115 120 170 185 205 280 29557 57 57 57 57 57 57 57 60 60 59 59 62 62 62
M.5 M.6 M.8 M.9 T.8 T.9 T.11 T.14 T.16 T.18 T.20 T.24 T.28 T.35 T.43Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1R1 R1 R1 R1 R1 R1 R2 R2 R2 R2 R3 R3 R3 R4 R45,2 6,3 7,4 8,6 7,4 8,6 10,8 12,8 15,3 17,2 20,5 24,1 27,2 33 41,16,2 7,7 8,9 10,6 8,7 10,5 13,4 15,8 18,6 21,4 24,9 29,2 32,9 40,7 49,51 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1,5 2 2,6 3 2,5 2,9 3,4 4,5 5,1 6 5,9 7,6 9,1 11,3 13,61,7 2,4 2,6 3,2 2,6 3,1 3,7 4,4 5,1 5,8 6,7 8 8,8 11,2 13,41 1 1 1 1 1 1 1 1 1 1 1 1 1 1
80 80 82 83 82 83 105 108 115 120 179 194 214 294 30957 57 57 57 57 57 57 57 60 60 59 59 62 62 62
(1) Referred to chilled water temperature 12/7°C and condenser water inlet temperature 30°C(2) Referred to hot water outlet temperature 45°C and outdoor temperature at 7°C
POWER SUPPLY: M = 230.1.50 T = 400.3.50+N
DIMENSIONS (mm)
Size a b c
R1 1.048 460 836
R2 1.305 580 900
R3 1.305 580 1.285
R4 1.805 580 1.285
73RC GROUP SpA • C_GNR_0507
EASY_air cooled liquid chillers / heat pumps
cooling capacity • 48,1 ÷ 505,3 kWheating capacity • 59,1 ÷ 592,1 kWcompressors • scrollrefrigerant • R407Cfan type • axialmicroprocessor • MP.COMmodels • 76
74 RC GROUP SpA • C_GNR_0507
EASY
GENERAL FEATURES
EASY liquid chillers allows to meet all air-conditio-ning requirements in residential, commercial and hi-tech applications, as well as in the post industrial sector.
These machines are available in a full range of di-mensions, models and versions, with a rich variety of accessories and optional, so that they can become the ideal solution for installation in office buildings, public buildings, trade centres, industrial buildings, wine-cellars as well as for a variety of other applica-tions in the hi-tech and process sector.
Low noise levels, with the possibility of selecting either the silenced range or the extremely low noise ELN range.This allows you to select the machine you want also from the acoustic standpoint, in addition to the heating/cooling capacity, and to meet the strictest requirements in terms of protection against sound emissions.
Heavy duty construction, thanks to their design and
the policies followed for the machines meant for criti-cal environments, where they are required to operate 24/7/365.In this way, continuous and regular operation of the ma-chines is ensured under any load conditions.
EASY “U” - “N”
air cooled liquid chillers / heat pumps
VERSIONS:
EASY (R407C)
Cooling capacity 48,9 ÷ 505,3 kW
Liquid chiller equipped with scroll compressors
and axial fans.
EASY.ELN (R407C)
Cooling capacity 50,7 ÷ 259,7 kW
Extremely low noise liquid chiller equipped with
scroll compressors and axial fans.
EASY.P (R407C)
Cooling capacity 48,1 ÷ 500,8 kW
Heating capacity 59,1 ÷ 592,1 kW
Heat pump liquid chiller equipped with scroll
compressors and axial fans.
EASY.P.ELN (R407C)
Cooling capacity 50 ÷ 254,3 kW
Heating capacity 63,3 ÷ 317,3 kW
Extremely low noise heat pump liquid chiller
equipped with scroll compressors and axial fans.
75RC GROUP SpA • C_GNR_0507
EASY
. In some capacity ranges, the machines are manufactured in two diffe-rent versions:• with a single refrigeration circuit and several com-
pressors in parallel. This version makes it possi-
tial load working mode (S version).• with double refrigeration circuit, marked by an
industry (D version).
EASY “V”
air cooled liquid chillers / heat pumps
MAIN COMPONENTS
• Housing in epoxy painted galvanized steel sheet.
• Axial fans
• Welded plate heat exchangers
• Technical compartment separate from the air
• Modulating condensing control
• Antifreeze system
• Pump-Down stop system
• IDEA® defrosting system (EASY.P)
• Cycle reversing valve (EASY.P)
• MP.COM microprocessor control
• Electrical box in separate compartment
• Main switch with door lock safety
MAIN OPTIONAL ACCESSORIES
• Hydronic group
• LNO kit for noise reduction (EASY – EASY.P)
• Heat reclaim
• Serial port
IDEA® defrosting system“Patented” defrosting system with dynamic reading of working parameters. Thanks to proprietary sof-tware it senses the real presence of brine on the coil starting defrosting cycles only in that situation. This brings a remarkable energy saving (more than 20-30% on the average) and a higher working con-tinuity compared with traditional systems
76 RC GROUP SpA • C_GNR_0507
EASYair cooled liquid chillers / heat pumps
TECHNICAL DATA AND NOMINAL PERFORMANCES / ONLY COOLING
EASY single circuit
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
EASY double circuit
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.200 T.260Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z3-S Z3-SU5 U5 U6 U6 U7 U7 N8 N8 N948,9 57,3 68,4 84,6 107,1 133,9 163 199,5 254,5
2 2 2 2 2 2 2 3 315,6 17,3 22,6 26,9 38,6 45,4 58,8 67,9 83,4
1 1 1 1 1 1 1 1 1740 740 810 835 1060 1080 1560 1710 207061 61 62 62 67 71 69 72 71
T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.220 T.270 T.330 T.400 T.470 T.510Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z4-D Z4-D Z4-D Z6-D Z6-D Z6-DU5 U5 U6 U6 U7 U7 N8 N8 N9 N9 V2 V3 V347,4 56,1 71,1 82,6 107,5 134,3 163,6 218 267,1 326,7 398,7 467,8 505,3
2 2 2 2 2 2 2 4 4 4 6 6 615,2 17,1 23,8 26,8 38,7 45,5 58,9 73,8 90,7 116,8 134,5 144,8 165,1
2 2 2 2 2 2 2 2 2 2 2 2 2765 765 835 860 1090 1110 1580 1680 2200 2450 2970 3700 390061 61 62 62 67 71 69 72 71 73 74 73 76
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C
POWER SUPPLY: for Size U5 / U6: 400.3.50+Nfor Size U7 / N8 / N9 / V2 / V3: 400.3.50
EASY.ELN single circuit - extra low noise
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
EASY.ELN double circuit - extra low noise
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
T.55 T.68 T.84 T.110 T.130 T.160 T.200 T.260Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z3-S Z3-SU6 U6 U6 U7 N8 N8 N9 N950,7 68 78,3 104,7 129,6 160,4 192,4 242,6
2 2 2 2 2 2 3 319,6 25,5 29,2 39,7 47,9 59,8 72 89,5
1 1 1 1 1 1 1 1740 810 875 1110 1510 1650 1980 220046 53 54 59 61 61 61 64
T.55 T.68 T.84 T.110 T.130 T.160 T.220 T.270Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z4-D Z4-DU6 U6 U6 U7 N8 N8 N9 N950,7 68,3 78 105,1 130 160,9 207,7 259,7
2 2 2 2 2 2 4 419,6 25,5 29,1 39,8 48 59,9 79,2 95,4
2 2 2 2 2 2 2 2765 835 900 1140 1530 1690 1980 234046 53 54 59 61 61 61 65
77RC GROUP SpA • C_GNR_0507
EASYair cooled liquid chillers / heat pumps
TECHNICAL DATA AND NOMINAL PERFORMANCES / HEAT PUMPS
EASY.P single circuit
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
EASY.P double circuit
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.200 T.260Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z3-S Z3-SU5 U5 U6 U6 U7 U7 N8 N8 N948,1 56,1 68 83,8 105,5 130,8 157,9 189,9 249,459,1 68 82,4 99,2 129,6 157,7 196,2 233,1 301,9
2 2 2 2 2 2 2 3 315,6 17,2 22,6 26,9 38,4 45,3 58,3 67,5 83,215,9 18,3 22,8 27 37,1 44,6 55,6 66,3 80,8
1 1 1 1 1 1 1 1 1750 750 820 845 1110 1130 1580 1830 209061 61 62 62 67 71 69 72 71
T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.220 T.270 T.330 T.400 T.470 T.510Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z4-D Z4-D Z4-D Z6-D Z6-D Z6-DU5 U5 U6 U6 U7 U7 N8 N8 N9 N9 V2 V3 V346,6 54,7 66,6 81,7 105,6 133,5 162,2 214,5 261,1 316,4 393,5 462,5 500,857,3 66,3 82,3 97,5 129,6 159,5 199,4 263,9 316,4 393,1 464,1 542,9 592,1
2 2 2 2 2 2 2 4 4 4 6 6 615,2 17,1 23,8 26,8 38,5 45,4 58,8 73,6 90,4 115,9 134,3 144,6 164,915,5 17,9 23,5 26,8 36,3 43,7 54,9 74,6 86,4 108,4 130 145,7 161,7
2 2 2 2 2 2 2 2 2 2 2 2 2790 790 860 885 1155 1175 1600 1700 2230 2470 3180 3900 410061 61 62 62 67 71 69 72 71 73 74 73 76
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water outlet temperature 45°C and outdoor temperature at 7°C
POWER SUPPLY: for Size U5 / U6: 400.3.50+Nfor Size U7 / N8 / N9 / V2 / V3: 400.3.50
EASY.P.ELN single circuit - extra low noise
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
EASY.P.ELN double circuit - extra low noise
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
T.55 T.68 T.84 T.110 T.130 T.160 T.200 T.260Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z3-S Z3-SU6 U6 U6 U7 N8 N8 N9 N950 67,5 77,7 103,2 127,1 155,7 184,2 238,6
63,3 83,3 96,8 130,4 158,5 198,1 232,6 299,72 2 2 2 2 2 3 3
19,5 25,5 29,1 39,6 47,6 59,4 71,2 8918,1 23,8 27 37,3 44,8 55,9 66,6 81,2
1 1 1 1 1 1 1 1750 820 885 1160 1530 1690 2000 210046 53 54 59 61 61 61 64
T.55 T.68 T.84 T.110 T.130 T.160 T.220 T.270Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z4-D Z4-DU6 U6 U6 U7 N8 N8 N9 N949,9 64,4 77,3 103,3 129,3 159,7 205 254,363,2 80,8 96,7 130,4 160,3 201,3 260,8 317,3
2 2 2 2 2 2 4 419,5 25,3 29,1 39,7 47,9 59,8 78,8 9518 23,4 27 36,5 43,9 55,2 74,6 86,82 2 2 2 2 2 2 2
790 860 925 1205 1550 1710 2000 223046 53 54 59 61 61 61 65
78 RC GROUP SpA • C_GNR_0507
EASY
ab
c
b
c
a
air cooled liquid chillers / heat pumps
DIMENSIONS (mm)
Size a b c
U5 2.000 1.200 1.630
U6 2.580 1.200 1.630
U7 3.020 1.200 1.950
N8 4.400 1.800 1.990
N9 5.400 1.800 1.990
Size a b c
V2 3.756 2.310 2.490
V3 4.900 2.310 2.490
79RC GROUP SpA • C_GNR_0507
UNICO_air cooled liquid chillers
cooling capacity • 20,7 ÷ 1475,4 kWcompressor • scroll / reciprocating / centrifugalfan type • axial / centrifugalrefrigerant • R407C / R134amicroprocessor • MP.99 / MP.COMmodels • 102
80 RC GROUP SpA • C_GNR_0507
UNICOair cooled liquid chillers
MULTIPLICITY OF VERSIONSAND COMPONENTS
The wide range of cooling capacity, from 21 to 1475 kW and the available versions, make possible the use and the combination of different components on the refrigeration and hydraulic circuits in the UNICOchillers range.Indeed, they can be equipped with scroll, reciproca-ting, screw and centrifugal type compressors; plate and shell and tube type evaporators; axial and cen-trifugal type fan.The high energy efficiency is granted by a general design that foresees an independent refrigeration circuit for each compressor installed on the unit.The components completeness together with the wide range of available optional accessories allow very quick and easy installation operations; the units simply need electrical and hydraulic connections.
VERSIONS:
UNICO.A (R407C)
Cooling capacity 22,3 ÷ 279,5 kW
Liquid chiller equipped with scroll / reciprocating
compressors and axial fans.
UNICO.A.ELN (R407C)
Cooling capacity 21,1 ÷ 278,3 kW
Extremely low noise liquid chiller equipped with
scroll / reciprocating compressors and axial fans.
UNICO.C (R407C)
Cooling capacity 21 ÷ 270,7 kW
Liquid chiller equipped with scroll / reciprocating
compressors and centrifugal fans.
UNICO.C.ELN (R407C)
Cooling capacity 20,7 ÷ 190,9 kW
Extremely low noise liquid chiller equipped with
scroll / reciprocating compressors and
centrifugal fans.
UNICO.A.HD (R407C)
Cooling capacity 494 ÷ 1475,4 kW
Liquid chiller equipped with reciprocating com-
pressors and axial fans.
UNICO.A.HD.ELN (R407C)
Cooling capacity 492,9 ÷ 728,8 kW
Extremely low noise liquid chiller equipped with
reciprocating compressors and axial fans.
UNICO.TURBO.A (R134a)
Cooling capacity 250 ÷ 1200 kW
Liquid chiller equipped with magnetic levitation two-
stage centrifugal compressors and axial fans.
UNICO.A “G”
UNICO.HD. “M”
81RC GROUP SpA • C_GNR_0507
UNICOair cooled liquid chillers
MAIN COMPONENTS
• Housing in anodised aluminium profile frame.
Panels in galvanized steel sheet externally
coated with PVC film (Size Y excluded).
• Scroll / reciprocating / centrifugal compressors
• Axial / centrifugal fans
• Welded plate / shell and tube evaporator
• Pump-down stop system
• Technical compartment separate from
the air flow
• MP.COM microprocessor control (TURBO)
• MP.99 microprocessor control
• Electrical box in separate compartment
• Main switch with door lock safety
MAIN OPTIONAL ACCESSORIES
• Pumping group
• Water tank
• LNO kit for noise reduction
• Partial or total heat reclaim
• Water flow safety switch
• “Brine A” and “Brine B” kit for chilled water pro-
duction with temperatures down to -10°C.
• Serial port
UNICO.C “G”
“A” CLASS ENERGY EFFICIENCY VERSIONThe UNICO.TURBO series is characterized by its high
working conditions during the year, thanks to the special compressor installed in these units.
The UNICO.TURBO liquid chillers are provided with an innovative two-stage centrifugal compressor with magnetic levitation bearings providing deliver revolutionary features and benefits compared to the traditional machines available in the market.First of all, the magnetic levitation bearings elimi-nate the presence of oil inside the compressor and consequently inside the refrigerant circuit, while the compressor electric motor is controlled by an inverter, obtaining a continuous cooling capacity variation from 20 to 100%.
The cooling capacity is controlled also by the movable inlet guide vane system on the compressor’s suction port that diverts the angle of the gas entering the impeller as needed.This allows to follow with considerable accuracy the trend of system thermal load.
UNICO.TURBO “Y”
UNICO.TURBO “F”
UNICO.HD. “U”
82 RC GROUP SpA • C_GNR_0507
UNICOair cooled liquid chillers
UNICO.A axial fans
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
21 25 32 37 50 61 36 42 50Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2G0 G0 G2 G2 G2 G4 G2 G2 G222,3 25,3 33,2 40,1 54,2 62,4 37,8 44,6 50,5
1 1 1 1 1 1 2 2 27,5 8,7 11,6 12,7 17,5 23,3 11,7 14,9 17,41 1 1 1 1 1 2 2 2
330 330 480 540 590 750 570 590 61062 62 62 64 64 64 64 64 64
TECHNICAL DATA AND NOMINAL PERFORMANCES
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
64 74 87 100 124 170 220 260 300Z2 Z2 Z2 Z2 Z2 Z2 F2 F2 F2G4 G4 G6 G6 G6 G7 G8 G8 G867,3 77,1 95,4 107 131,7 169,7 199,2 246,7 279,5
2 2 2 2 2 2 2 2 222,7 26 28,9 34,5 44,2 51,7 63,1 75,8 93,1
2 2 2 2 2 2 2 2 2820 860 1180 1240 1240 1530 2095 2435 245064 65 65 65 66 66 68 74 74
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C
POWER SUPPLY: 400.3.50+N
UNICO.A.ELN axial fans / extra low noise
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
21 25 32 37 50 61 36 42 50Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2G2 G2 G2 G4 G4 G4 G4 G4 G421,1 24,3 32,4 38,6 51 62 36,3 42,6 49,3
1 1 1 1 1 1 2 2 27,9 9,1 12,1 13,5 19,1 23,6 12,6 15,7 17,91 1 1 1 1 1 2 2 2
460 460 500 680 770 790 720 750 75050 53 51 53 54 55 53 51 55
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
64 74 87 100 124 170 220 260 300Z2 Z2 Z2 Z2 Z2 Z2 F2 F2 F2G4 G6 G7 G7 G7 G8 G8 G9 G962,5 72,1 89,5 98,9 128 165,3 184,8 238,5 278,3
2 2 2 2 2 2 2 2 225,4 28,7 32,1 38,9 46,4 53,6 66,2 77,2 93,3
2 2 2 2 2 2 2 2 2820 1120 1230 1290 1340 1800 2090 3278 345455 53 56 56 57 54 57 60 63
83RC GROUP SpA • C_GNR_0507
UNICOair cooled liquid chillers
UNICO.A.HD axial fans
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
550 550 600 600 660 660 770 770 880 880S2 S2 S2 S2 S2 S2 S2 S2 S2 S2
U10 M16 U11 M16 U11 M16 U12 M17 U13 M17494 505,9 562,5 557,3 599,9 598,7 704,6 703 797,3 778,72 2 2 2 2 2 2 2 2 2
156,3 153,9 170 170,9 186,4 186,6 217,3 217,6 246,4 250,42 2 2 2 2 2 2 2 2 2
4460 4900 4960 5080 5140 5080 5870 5780 6540 594076 85 76 85 76 85 77 85 78 85
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
990 990 1100 1100 1210 1320 1420 1530 1640S2 S2 S2 S2 S3 S3 S3 S3 S3
U14 M18 U14 M18 M19 M20 M20 M21 M21918,8 897,7 992 976,1 1095,9 1198,8 1298,1 1405 1475,4
2 2 2 2 3 3 3 3 3277,5 281,6 309 311,7 346,7 375 411,6 437,7 469,6
2 2 2 2 3 3 3 3 37140 6620 7150 6620 8350 9160 9420 9600 960078 85 78 86 85 85 85 85 85
TECHNICAL DATA AND NOMINAL PERFORMANCES
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C
POWER SUPPLY: 400.3.50+N
UNICO.A.HD.ELN axial fans / extra low noise
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
550 600 660 770 880S2 S2 S2 S2 S2
U11 U12 U12 U13 U14492,9 557,5 593,3 693,2 782,8
2 2 2 2 2156,5 170,9 187,8 219,6 249,3
2 2 2 2 24960 5670 5670 6370 702063 63 63 64 64
UNICO.TURBO.A axial fans
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
250 300 500 600 750 900 1000 1200
T1.Y1 T1.Y2 T2.Y3 T2.Y4 T3.F12 T3.F14 T4.F16 T4.F20250 300 500 600 750 900 1000 12001 1 2 2 3 3 4 4
70,5 76,5 138,1 159,3 199,3 234,2 267,7 312,31 1 2 2 1 1 2 2
1825 2380 3800 4610 6600 7100 8600 910073,0 73,6 74,5 74,8 75,8 76,0 76,3 76,5
84 RC GROUP SpA • C_GNR_0507
UNICO
UNICO.C centrifugal fans
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
21 25 32 37 50 61 36 42 50Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2G1 G1 G1 G3 G3 G3 G3 G3 G321 23,9 32 38,8 51,7 62,7 36,1 42,1 481 1 1 1 1 1 2 2 28 9,4 12,4 13,4 18,6 23,1 12,7 16 18,81 1 1 1 1 1 2 2 2
390 390 435 670 740 760 690 710 72059 59 66 60 68 68 59 60 64
TECHNICAL DATA AND NOMINAL PERFORMANCES
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
64 74 87 100 124 170 220 260 300Z2 Z2 Z2 Z2 Z2 Z2 F2 F2 F2G3 G5 G7 G7 G7 G7 G8 G8 G863,5 77,1 91,9 101,9 129 165,2 187,9 236,7 270,7
2 2 2 2 2 2 2 2 224,8 26 31 37 45,6 53,6 65,6 77,7 95,1
2 2 2 2 2 2 2 2 2790 1060 1450 1510 1540 1730 2380 2740 277068 70 69 69 69 71 75 77 78
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C
POWER SUPPLY: 400.3.50+N
UNICO.C.ELN centrifugal fans / extra low noise
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
21 25 32 37 50 61 36 42Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2G3 G3 G3 G5 G5 G5 G5 G520,7 23,9 31,9 37 50,3 62,6 34,5 41
1 1 1 1 1 1 2 28,2 9,4 12,5 14,4 19,5 23,1 13,6 16,71 1 1 1 1 1 2 2
590 590 630 840 900 910 860 88047 49 51 53 54 58 52 55
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
50 64 74 87 100 124 170 220Z2 Z2 Z2 Z2 Z2 Z2 Z2 F2G5 G5 G7 G8 G8 G8 G8 G848 63,5 71,6 91,3 101,2 127,5 165,5 190,92 2 2 2 2 2 2 2
18,7 24,8 29 31,2 37,4 46,8 53,5 64,92 2 2 2 2 2 2 2
920 970 1360 1850 1910 1970 2030 239554 58 55 56 56 56 61 67
air cooled liquid chillers
85RC GROUP SpA • C_GNR_0507
UNICO
b a
c
ba
c
ba
c
air cooled liquid chillers
DIMENSIONS (mm)
Size a b c
G0 1.150 895 1.640
G2 2.000 1.040 1.690
G4 2.600 1.200 1.690
G6 3.600 1.290 1.690
G7 3.600 1.290 2.115
G8 5.170 1.290 2.155
G9 5.900 1.540 2.470
UNICO.A / “G”
Size a b c
U10 5.500 2.130 2.430
U11 6.490 2.130 2.430
U12 7.480 2.130 2.430
U13 8.470 2.130 2.430
U14 9.460 2.130 2.430
UNICO.A.HD / “U”
Size a b c
M16 5.000 2.350 2.510
M17 6.070 2.350 2.510
M18 7.140 2.350 2.510
M19 8.490 2.350 2.510
M20 9.560 2.350 2.510
M21 10.630 2.350 2.510
UNICO.A.HD / “M”
86 RC GROUP SpA • C_GNR_0507
UNICO
ba
c
b
c
a
ab
c
air cooled liquid chillers
DIMENSIONS (mm)
Size a b c
G1 1.150 895 1.960
G3 2.000 1.040 2.010
G5 2.600 1.200 2.010
G7 3.600 1.290 2.010
G8 5.170 1.290 2.050
UNICO.C / “G”
Size a b c
250.T1.Y1 2.606 2.310 2.490
300.T1.Y2 3.576 2.310 2.490
500.T2.Y3 4.906 2.310 2.490
600.T2.Y4 6.056 2.310 2.490
UNICO.TURBO / “Y”
Size a b c
750.T3.F12 7.860 2.320 2.560
900.T3.F14 8.930 2.320 2.560
1000.T4.F16 10.550 2.320 2.560
1200.T4.F20 12.960 2.320 2.560
UNICO.TURBO / “F”
87RC GROUP SpA • C_GNR_0507
GLIDER_air cooled liquid chilled chillers / heat pumps
cooling capacity • 189,7 ÷ 1613,1 kWheating capacity • 203,1 ÷ 1613,1 kWcompressors • screwrefrigerant • R134afan type • axialmicroprocessor • MP.COMmodels • 45
88 RC GROUP SpA • C_GNR_0507
GLIDER
2,5
3
3,1
3,5
560235 885 1210 1535kW
EER
air cooled liquid chilled chillers / heat pumps
GENERAL FEATURES
The GLIDER units are a complete range including liquid chillers and heat pumps, with high energy efficiency and reduced operating costs, granting an efficacious answer to the today’s needs of “comfort” and hi-tech air conditioning well as in the industrial process cooling.Developed with the most advanced 3D-CAD softwa-re, GLIDER chillers are available in two brand new cabinet types (for more a rational internal layout), an extremely innovative condenser fan section and the state of the art of electrical, electronics and refrigerating components.
A-CLASSGLIDER chillers stand out for the high efficiency of the whole series.The graphic beside shows EER values for GLIDER and GLIDER.CLA versions, in comparison to the 3,1 A-Class* energy ratio.
*In agreement with EECCAC (Energy Efficiency and Certification of Central Air Conditioning).
VERSIONS :
GLIDER (R134a)
Cooling capacity 189,7 ÷ 1537,2 kW
Liquid chiller equipped with screw compressors
and axial fans.
GLIDER.CLA (R134a)
Cooling capacity 199,8 ÷ 1613,1 kW
Liquid chiller with A-Class Energy Efficiency
(EER > 3,1) equipped with screw compressors
and axial fans.
GLIDER.ELN (R134a)
Cooling capacity 193,5 ÷ 1538,4 kW
Extremely low noise liquid chiller equipped with screw
compressors and axial fans.
GLIDER.HP (R134a)
Cooling capacity 188,8 ÷ 999,7 kW
Heating capacity 203,1 ÷ 1077,5 kW
Heat pump liquid chiller equipped with screw com-
pressors and axial fans.
GLIDER “Y”
89RC GROUP SpA • C_GNR_0507
GLIDERair cooled liquid chilled chillers / heat pumps
MAIN COMPONENTS
• Housing in epoxy painted galvanized steel
profiles.
• Screw compressors
• Axial fans with stepless speed control
• Shell and tube evaporator with one
refrigerant circuit for each compressor
• Electronic expansion valve
• IDEA® defrosting system (GLIDER.HP)
• Cycle reversing valve (GLIDER.HP)
• Pump-Down stop system
• MP.COM microprocessor control
• Electrical box in separate compartment
• Main switch with door lock safety
GLIDER “F”
V-WINGSGLIDER chillers are equipped with direct driven axial fans, coupled to 6-poles electric motors and protected by special safety mesh.Units with “F” cabinet use the same type of fans, but are inclined in the horizontal axis.This innovative solution have also highlighted the following advantages:• uniform air distribution over the complete
condenser coil• reduction of hot air recirculation• low noise emission
GLIDER “N”
IDEA® defrosting systemGLIDER.HP version
“Patented” defrosting system with dynamic reading of working parameters. Thanks to proprietary software it senses the real presence of brine on the coil starting defrosting cycles only in that situation. This brings a remarkable energy saving (more than 20-30% on the average) and a higher working continuity compared with traditional systems.
MAIN OPTIONAL ACCESSORIES
• Pumping group
• Water tank
• Partial or total heat reclaim
• LNO kit for noise reduction
• “Brine A” and “Brine B” kit for chilled
water production with temperatures
down to -10°C.
• Serial port
90 RC GROUP SpA • C_GNR_0507
GLIDERair cooled liquid chilled chillers / heat pumps
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Sound pressure 1m far in free field conditions according to ISO3744 normsPOWER SUPPLY: 400.3.50
TECHNICAL DATA AND NOMINAL PERFORMANCES
GLIDER
GLIDER.CLA
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Sound pressure 1m far in free field conditions according to ISO3744 normsPOWER SUPPLY: 400.3.50
Model
Cooling capacity (1) kWCompressors n.Power input kWGas circuits n.Weight kgSound pressure (2) dB(A)
190 230 270 330 380 440 500 580 640 690V2.N8 V2.N8 V2.N8 V2.N8 V2.Y2 V2.Y2 V2.Y2 V2.Y3 V2.Y3 V2.Y3189,7 228,0 268,8 321,5 370,7 435,7 497,3 573,2 637,4 693,2
2 2 2 2 2 2 2 2 2 258,5 68,0 86,6 107,3 116,1 131,1 155,2 168,3 201,4 212,8
2 2 2 2 2 2 2 2 2 22.231 2.251 2.396 2.656 3.062 3.267 3.587 4.026 4.123 4.26373,1 73,1 73,1 73,2 73,2 75,9 75,9 76,2 78,0 78,0
Model
Cooling capacity (1) kWCompressors n.Power input kWGas circuits n.Weight kgSound pressure (2) dB(A)
750 840 920 1020 1150 1240 1360 1410 1540V2.Y4 V2.Y4 V2.F10 V2.F10 V3.F12 V3.F14 V3.F16 V3.F16 V3.F16746,5 845,8 920,5 1.019,2 1.147,1 1.241,0 1.355,9 1.410,5 1.537,2
2 2 2 2 3 3 3 3 3231,6 261,8 306,3 322,1 367,7 398,4 413,1 449,6 475,1
2 2 2 2 3 3 3 3 35.007 5.433 7.405 7.545 9.399 10.313 11.357 11.617 11.84778,9 78,7 78,7 78,7 79,7 79,9 79,9 80,0 80,0
Model
Cooling capacity (1) kWCompressors n.Power input kWGas circuits n.Weight kgSound pressure (2) dB(A)
200 240 280 350 390 450 520 590 680 730V2.N8 V2.N8 V2.N8 V2.Y2 V2.Y2 V2.Y2 V2.Y3 V2.Y3 V2.Y4 V2.Y4199,8 232,7 275,9 340,5 388,0 446,4 518,7 586,8 673,9 731,7
2 2 2 2 2 2 2 2 2 254,3 68,7 83,8 99,7 109,4 127,0 147,0 163,3 187,5 198,3
2 2 2 2 2 2 2 2 2 22.231 2.386 2.396 2.862 3.062 3.387 3.961 4.166 4.507 4.77773,1 73,1 73,1 73 73,9 75,9 76,2 76,2 78,1 78,1
Model
Cooling capacity (1) kWCompressors n.Power input kWGas circuits n.Weight kgSound pressure (2) dB(A)
780 880 950 1020 1090 1210 1300 1410 1500 1610V2.Y4 V2.F10 V2.F12 V2.F14 V2.F14 V3.F16 V3.F16 V3.F18 V3.F20 V3.F20775,9 876,6 947,4 1.015,8 1.089,1 1.213,2 1.296,9 1.409,7 1.495,3 1.613,1
2 2 2 2 2 3 3 3 3 3225,0 253,3 267,7 277,9 298,3 342,2 382,6 399,9 420,1 453,5
2 2 2 2 2 3 3 3 3 35.395 7.425 8.069 8.913 9.013 10.807 11.327 12.176 13.150 13.30078,9 78,7 78,7 78,9 78,9 79,8 79,9 80,0 80,1 80,1
91RC GROUP SpA • C_GNR_0507
GLIDERair cooled liquid chilled chillers / heat pumps
TECHNICAL DATA AND NOMINAL PERFORMANCES
GLIDER.HP heat pump
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Sound pressure 1m far in free field conditions according to ISO3744 normsPOWER SUPPLY: 400.3.50
GLIDER.ELN extra low noise
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water outlet temperature at 45°C and outdoor temperature at 7°C(3) Sound pressure 1m far in free field conditions according to ISO3744 normsPOWER SUPPLY: 400.3.50
Model
Cooling capacity (1) kWCompressors n.Power input kWGas circuits n.Weight kgSound pressure (2) dB(A)
200 230 280 350 390 450 520 570 660 690V2.N8 V2.N8 V2.N9 V2.Y2 V2.Y2 V2.Y3 V2.Y3 V2.Y3 V2.Y4 V2.Y4193,5 227,4 277,9 344,4 382,8 449,9 510,0 564,3 651,3 688,9
2 2 2 2 2 2 2 2 2 261,4 74,0 87,9 104,0 121,9 133,2 163,5 181,9 207,7 227,0
2 2 2 2 2 2 2 2 2 22.321 2.341 2.794 3.012 3.397 3.911 4.156 4.316 4.657 4.75764,1 64,1 64,6 63,3 63,3 64,4 64,4 64,4 65,5 65,5
Model
Cooling capacity (1) kWCompressors n.Power input kWGas circuits n.Weight kgSound pressure (2) dB(A)
740 820 900 940 1030 1170 1240 1300 1400 1540V2.Y4 V2.F10 V2.F12 V2.F12 V2.F12 V3.F16 V3.F16 V3.F16 V3.F18 V3.F20734,4 813,2 893,7 938,7 1.021,3 1.169,1 1.235,1 1.299,3 1.397 1.538,4
2 2 2 2 2 3 3 3 3 3250,4 290,9 295,0 323,1 340,3 380,5 424,2 461,6 482,5 502,7
2 2 2 2 2 3 3 3 3 35.327 7.433 8.137 8.279 8.499 10.957 11.247 11.507 12.416 13.45065,8 67,6 67,7 67,8 67,8 68,5 68,6 68,6 68,7 68,8
Model
Cooling capacity (1) kWHeating capacity (2) kWCompressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
190 230 270 330 380 440 500V2.N8 V2.N8 V2.N8 V2.N8 V2.Y2 V2.Y2 V2.Y2189,1 227,0 267,2 319,0 366,7 429,1 487,6203,1 246,0 287,4 347,8 394,7 454,2 530,1
2 2 2 2 2 2 258,4 68,0 86,5 107,0 115,7 130,5 154,357,2 68,9 77,1 92,6 106,1 119,7 144,2
2 2 2 2 2 2 22.381 2.401 2.546 2.806 3.382 3.567 3.88773,1 73,1 73,1 73,2 73,2 75,9 75,9
Model
Cooling capacity (1) kWHeating capacity (2) kWCompressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
580 640 690 750 840 920 1020V2.Y3 V2.Y3 V2.Y3 V2.Y4 V2.Y4 V2.F10 V2.F10558,5 617,9 668,0 731,8 825,0 906,1 999,7592,0 656,2 720,9 782,0 893,1 974,2 1077,5
2 2 2 2 2 2 2167,1 199,4 210,4 230,2 259,8 303,8 319,1156,0 175,5 191,0 216,3 239,5 267,2 280,3
2 2 2 2 2 2 24.326 4.423 4.663 5.357 5.803 7.805 8.04576,2 78,0 78,0 78,9 78,7 78,7 78,7
92 RC GROUP SpA • C_GNR_0507
GLIDER
b
c
a
ab
c
ab
c
air cooled liquid chilled chillers / heat pumps
DIMENSIONS (mm)
Size a b c
V2.Y2 3.756 2.310 2.490
V2.Y3 4.900 2.310 2.490
V2.Y4 6.056 2.310 2.490
Size a b c
V2.F10 6.790 2.320 2.560
V2.F12 7.860 2.320 2.560
V2.F14 8.930 2.320 2.560
V3.F12 8.410 2.320 2.560
V3.F14 9.480 2.320 2.560
V3.F16 10.550 2.320 2.560
V3.F18 11.620 2.320 2.560
V3.F20 12.690 2.320 2.560
Size a b c
V2.N8 4.400 1.800 1.990
V2.N9 5.400 1.800 1.990
GLIDER “N”
GLIDER “Y”
GLIDER “F”
93RC GROUP SpA • C_GNR_0507
REVERSO_air cooled heat pump liquid chillers
cooling capacity • 20,4 ÷ 985,7 kWheating capacity • 25 ÷ 1079,9 kWcompressors • scroll / reciprocatingfan type • axial / centrifugalrefrigerant • R407Cmicroprocessor • MP.99models • 82
94 RC GROUP SpA • C_GNR_0507
REVERSOair cooled heat pump liquid chillers
MULTIPLICITY OF VERSIONSAND COMPONENTS
The wide range of cooling capacity, from 21 to 1079 kW and the available versions, make possible the use and the combination of different components on the refrigeration and hydraulic circuits in theREVERSO heat pumps range.
Indeed, they can be equipped with scroll and re-ciprocating type compressors; plate and shell and tube type evaporators; axial and centrifugal type fans.
The REVERSO heat pump chillers series are the ideal solution for all those applications where the air conditioning is needed all year long, cooling in sum-mer and heating in winter. The peculiarity of the RC GROUP heat pumps is the IDEA® defrosting system.
The components completeness together with the wide range of available optional accessories allow very quick and easy installation operations; the units simply need electrical and hydraulic connections.
VERSIONS:
REVERSO.A.P (R407C)
Cooling capacity 21,9 ÷ 274,7 kW
Heating capacity 25,7 ÷ 293,2 kW
Heat pump liquid chiller equipped with scroll / reci-
procating compressors and axial fans.
REVERSO.A.P.ELN (R407C)
Cooling capacity 20,8 ÷ 274,9 kW
Heating capacity 25,8 ÷ 306,7 kW
Extremely low noise heat pump liquid chiller equip-
ped with scroll / reciprocating compressors and axial
fans.
REVERSO.C.P (R407C)
Cooling capacity 20,7 ÷ 266,4 kW
Heating capacity 25 ÷ 298,2 kW
Heat pump liquid chiller equipped with scroll / reci-
procating compressors and centrifugal fans.
REVERSO.C.P.ELN (R407C)
Cooling capacity 20,4 ÷ 191,4 kW
Heating capacity 25,5 ÷ 224,3 kW
Extremely low noise heat pump liquid chiller equip-
ped with scroll / reciprocating compressors and
centrifugal fans.
REVERSO.HD.A.P (R407C)
Cooling capacity 491,6 ÷ 985,7 kW
Heating capacity 542,3 ÷ 1079,9 kW
Heat pump liquid chiller equipped with reciprocating
compressors and axial fans.
REVERSO.HD.A.P.ELN (R407C)
Cooling capacity 503,3 ÷ 784,8 kW
Heating capacity 554,9 ÷ 879,8 kW
Extremely low noise heat pump liquid chiller equipped
with reciprocating compressors and axial fans.
REVERSO.A.P “G”
95RC GROUP SpA • C_GNR_0507
REVERSOair cooled heat pump liquid chillers
MAIN OPTIONAL ACCESSORIES
• Pumping group
• Water storage tank
• Partial heat reclaim
• LNO kit for noise reduction
• Water flow safety switch
• Serial port
REVERSO.HD.A.P “U”
MAIN COMPONENTS
• Housing in anodised aluminium profile
frame. Panels in galvanized steel sheet
externally coated with PVC film.
• Scroll / reciprocating compressors
• Axial / centrifugal fans
• Welded plate / shell and tube evaporator
• Cycle reversing valve
• IDEA® defrosting system
• Pump-Down stop system
• MP.99 microprocessor control
• Electrical box in separate compartment
• Main switch with door lock safety
REVERSO.C.P “G”
IDEA® defrosting system“Patented” defrosting system with dynamic reading of working parameters. Thanks to proprietary software it senses the real presence of brine on the coil starting defrosting cycles only in that situation. This brings a remarkable energy saving (more than 20-30% on the average) and a higher working continuity compared with traditional systems.
96 RC GROUP SpA • C_GNR_0507
REVERSO
REVERSO.HD.A.P axial fans
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
550 600 660 770 880 990 1100S2 S2 S2 S2 S2 S2 S2
U10 U11 U11 U13 U13 U14 U14491,6 554 589 719,1 800,2 909,9 985,7542,3 612,2 650,4 794,6 883,4 998,9 1079,9
2 2 2 2 2 2 2156,4 169,4 185,6 214,3 247,7 277,1 309143,4 158,5 170,7 203,4 231,2 256,6 280,4
2 2 2 2 2 2 25103 5680 5680 7023 7188 7860 786576 76 76 78 78 78 78
air cooled heat pump liquid chillers
REVERSO.A.P axial fans
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
21 25 32 37 50 61 36 42 50Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2G0 G0 G2 G2 G2 G4 G2 G2 G221,9 24,1 32,9 40 51,6 61,6 37,4 43,8 49,325,7 28,9 39,6 46,5 61,2 73 43,8 51,3 59,5
1 1 1 1 1 1 2 2 27,4 8,9 11,6 12,5 18,1 22,5 11,7 14,9 17,47,6 9 11,6 13,3 17,9 21,6 13 15,5 18,51 1 1 1 1 1 2 2 2
350 350 500 560 610 770 600 620 64062 62 62 64 64 64 64 64 64
TECHNICAL DATA AND NOMINAL PERFORMANCES
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
64 74 87 100 124 170 220 260 300Z2 Z2 Z2 Z2 Z2 Z2 F2 F2 F2G4 G4 G6 G6 G6 G7 G8 G8 G863,8 76,2 93,9 104,6 127,9 168 199,9 244,6 274,776,7 91,3 111 124,4 153,7 189,4 217,9 258,9 293,2
2 2 2 2 2 2 2 2 224,1 26 28,9 34,5 44 51,7 63,5 75,7 92,524,2 27,7 31,5 36,7 44,7 52 60 70,9 84,3
2 2 2 2 2 2 2 2 2850 890 1210 1270 1270 1590 2240 2490 254064 65 66 66 66 66 68 74 74
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water outlet temperature at 45°C and outdoor temperature at 7°C
POWER SUPPLY: 400.3.50+N
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water outlet temperature at 45°C and outdoor temperature at 7°C
POWER SUPPLY: 400.3.50
97RC GROUP SpA • C_GNR_0507
REVERSOair cooled heat pump liquid chillers
TECHNICAL DATA AND NOMINAL PERFORMANCES
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water outlet temperature at 45°C and outdoor temperature at 7°C
POWER SUPPLY: 400.3.50
REVERSO.HD.A.P.ELN axial fans / extra low noise
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
550 600 660 770 880S2 S2 S2 S2 S2
U12 U13 U13 U14 U14503,3 559 595 708,4 784,8554,9 616,2 654,8 792,5 879,8
2 2 2 2 2154 168,4 184,3 216,5 251
144,9 159,1 171,2 203,3 2312 2 2 2 2
6183 6735 6735 7570 773563 64 64 64 64
REVERSO.A.P.ELN axial fans / extra low noise
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
21 25 32 37 50 61 36 42 50Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2G2 G2 G2 G4 G4 G4 G4 G4 G420,8 23,8 32,1 38,2 50 60,3 35,9 41,9 48,325,8 29,6 39 46 60,1 73,4 43,4 51,1 58,9
1 1 1 1 1 1 2 2 27,9 9,1 12,1 13,5 18,9 23,5 12,6 15,7 17,97,7 9,1 11,6 13,3 17,9 21,7 13 15,6 18,51 1 1 1 1 1 2 2 2
480 480 520 700 790 810 750 780 78050 53 51 53 54 55 53 51 55
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
64 74 87 100 124 170 220 260 300Z2 Z2 Z2 Z2 Z2 Z2 F2 F2 F2G4 G6 G7 G7 G7 G8 G8 G9 G962,1 71,4 88,1 97,1 124,6 163,7 185,5 238,1 274,977,2 89,4 106,3 118,6 154 182,9 206,4 264,7 306,7
2 2 2 2 2 2 2 2 225,4 28,6 32,1 38,8 46 53,6 66,4 76,9 92,424,3 27,7 31,4 36,4 44,8 51,5 58,5 72,1 86,5
2 2 2 2 2 2 2 2 2850 1150 1260 1320 1370 1845 2220 3338 351955 53 56 56 57 54 57 60 62
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water outlet temperature at 45°C and outdoor temperature at 7°C
POWER SUPPLY: 400.3.50+N
98 RC GROUP SpA • C_GNR_0507
REVERSOair cooled heat pump liquid chillers
REVERSO.C.P centrifugal fans
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
21 25 32 37 50 61 36 42 50Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2G1 G1 G1 G3 G3 G3 G3 G3 G320,7 23,5 31,7 38,4 50,7 61 35,6 41,5 4725 28,4 38,1 45,3 59,2 72,4 42,5 49,8 56,71 1 1 1 1 1 2 2 28 9,3 12,4 13,4 18,6 22,9 12,7 16 18,7
7,7 9 11,6 13,2 17,8 21,5 12,9 15,5 18,31 1 1 1 1 1 2 2 2
410 410 455 690 760 780 720 740 75059 59 66 60 68 68 59 60 64
TECHNICAL DATA AND NOMINAL PERFORMANCES
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
64 74 87 100 124 170 220 260 300Z2 Z2 Z2 Z2 Z2 Z2 F2 F2 F2G3 G5 G7 G7 G7 G7 G8 G8 G863 76,2 90,5 99,9 125,5 163,7 188,6 235,1 266,476 91,3 106 118,2 151,7 188,8 214,8 261 298,22 2 2 2 2 2 2 2 2
24,8 26 31 36,9 45,4 53,6 65,8 77,6 94,624,1 27,7 31,1 36,2 44,5 52,1 59,8 71,6 85,4
2 2 2 2 2 2 2 2 2820 1090 1480 1540 1570 1775 2510 2775 283068 70 69 69 69 71 75 77 78
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water outlet temperature at 45°C and outdoor temperature at 7°C
POWER SUPPLY: 400.3.50+N
99RC GROUP SpA • C_GNR_0507
REVERSOair cooled heat pump liquid chillers
REVERSO.C.P.ELN centrifugal fans / extra low noise
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
21 25 32 37 50 61 36 42Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2G3 G3 G3 G5 G5 G5 G5 G520,4 23,4 31,6 36,6 49,3 60,9 34,1 40,425,5 29,4 39,3 44,9 59,6 73,9 42,2 50,1
1 1 1 1 1 1 2 28,2 9,4 12,5 14,4 19,4 22,9 13,6 16,77,7 9,1 11,7 13,3 17,9 21,7 13 15,61 1 1 1 1 1 2 2
610 610 650 860 920 930 890 91047 49 51 53 54 58 52 55
MODEL
SizeCooling capacity (1) kW Heating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
50 64 74 87 100 124 170 220Z2 Z2 Z2 Z2 Z2 Z2 Z2 F2G5 G5 G7 G8 G8 G8 G8 G847,1 63 70,9 89,9 99,2 124,1 163,9 191,458 77,7 87,4 107,9 120,5 153,9 192,4 224,32 2 2 2 2 2 2 2
18,7 24,8 29 31,2 37,3 46,4 53,5 65,318,4 24,3 27,5 31,4 36,5 44,9 52,4 61,2
2 2 2 2 2 2 2 2950 1000 1390 1880 1940 2000 2145 252554 58 55 56 56 56 61 67
TECHNICAL DATA AND NOMINAL PERFORMANCES
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water outlet temperature at 45°C and outdoor temperature at 7°C
POWER SUPPLY: 400.3.50+N
100 RC GROUP SpA • C_GNR_0507
REVERSO
ba
c
b a
c
ba
c
air cooled heat pump liquid chillers
DIMENSIONS (mm)
REVERSO.C.P / “G”
Size a b c
G1 1.150 895 1.960
G3 2.000 1.040 2.010
G5 2.600 1.200 2.010
G7 3.600 1.290 2.010
G8 5.170 1.290 2.050
Size a b c
G0 1.150 895 1.640
G2 2.000 1.040 1.690
G4 2.600 1.200 1.690
G6 3.600 1.290 1.690
G7 3.600 1.290 2.115
G8 5.170 1.290 2.215
G9 5.900 1.540 2.470
REVERSO.A.P / “G”
Size a b c
U10 5.500 2.130 2.430
U11 6.490 2.130 2.430
U12 7.480 2.130 2.430
U13 8.470 2.130 2.430
U14 9.460 2.130 2.430
REVERSO.HD.A.P / “U”
101RC GROUP SpA • C_GNR_0507
MAXIMO_air cooled liquid chillers with free-cooling system
cooling capacity • 20,7 ÷ 1675,6 kWfree-cooling capacity • 16,6 ÷ 1241,9 kWcompressors • scroll / reciprocating / screwfan type • axial / centrifugalrefrigerant • R407C / R134amicroprocessor • MP.99models • 141
102 RC GROUP SpA • C_GNR_0507
MAXIMO
MAXIMO.A “U”
air cooled liquid chillers with free-cooling system
MULTIPLICITY OF VERSIONS AND COMPONENTS
The wide range of cooling capacity, from 20 to 1675 kW and the available versions, make possible the use and the combination of diverse components on the refrigera-tion and hydraulic circuits in the MAXIMO Free-Cooling chillers range.Indeed, they can be equipped with scroll, reciprocating and screw type compressors; plate and shell and tube type evaporators; axial and centrifugal type fans.
VERSIONS:
MAXIMO.A
Cooling capacity 21,2 ÷ 267,3 kW (R407C)
Free-cooling capacity 18 ÷ 209 kW
Free-cooling liquid chiller equipped with scroll /
reciprocating compressors and axial fans.
MAXIMO.A.ELN
Cooling capacity 22,1 ÷ 273,4 kW (R407C)
Free-cooling capacity 22 ÷ 208,6 kW
Extremely low noise free-cooling liquid chiller
equipped with scroll / reciprocating compressors
and axial fans.
MAXIMO.C
Cooling capacity 20,7 ÷ 265,8 kW (R407C)
Free-cooling capacity 16,6 ÷ 175,9 kW
Free-cooling liquid chiller equipped with scroll /
reciprocating compressors and centrifugal fans.
MAXIMO.C.ELN
Cooling capacity 21,6 ÷ 187,4 kW (R407C)
Free-cooling capacity 20,1 ÷ 144 kW
Extremely low noise free-cooling liquid chiller
equipped with scroll / reciprocating compressors
and centrifugal fans.
MAXIMO.A.HD
Cooling capacity 476,6 ÷ 1489,2 kW (407C)
Free-cooling capacity 355,9 ÷ 1235,2 kW
Free-cooling liquid chiller equipped with recipro-
cating compressors and axial fans.
MAXIMO.A.HD.ELN
Cooling capacity 491,3 ÷ 569,2 kW )R407C)
Free-cooling capacity 409,9 ÷ 420 kW
Extremely low noise free-cooling liquid chiller
equipped with reciprocating compressors and
axial fans.
MAXIMO.SCREW.A
Cooling capacity 227,4 ÷ 1675,6 kW (R407C)
Free-cooling capacity 189,7 ÷ 1241,9 kW
Free-cooling liquid chiller equipped with screw
compressors and axial fans.
MAXIMO.SCREW.A.ELN
Cooling capacity 234,8 ÷ 722 kW (R407C)
Free-cooling capacity 200,7 ÷ 562,9 kW
Extremely low noise free-cooling liquid chiller
equipped with screw compressors and axial
fans.
MAXIMO.SCREW.A.FLX
Cooling capacity 444,5 ÷ 1162,6 kW (R134a)
Free-cooling capacity 310,8 ÷ 771,8 kW
Free-cooling liquid chiller equipped with screw
compressors and axial fans.
MAXIMO.SCREW.A.XTR
Cooling capacity 468,8 ÷ 1102,7 kW (R134a)
Free-cooling capacity 358,5 ÷ 660,4 kW
Extremely low noise free-cooling liquid chiller
equipped with screw compressors and axial
fans.
103RC GROUP SpA • C_GNR_0507
MAXIMOair cooled liquid chillers with free-cooling system
MAIN OPTIONAL ACCESSORIES
• Pumping group
• Water tank
• LNO kit for noise reduction
• Heat reclaim
• Water flow safety switch
• Optimizer system
• Glycol-free system
• Serial port
MAXIMO.C “G”
MAXIMO.A “W”
MAIN COMPONENTS
• Housing in anodised aluminium profile
frame. Panels in galvanized steel sheet
externally coated with PVC film
• Scroll / reciprocating / screw compressors
• Axial / centrifugal fans
• Welded plate / shell and tube evaporator
• Pump-Down stop system
• Proportional free-cooling system
• Technical compartment separate from the
air flow (Size W excluded)
• MP.99 microprocessor control system
• Electrical box in separate compartment
• Main switch with door lock safety
MAXIMO.A “G”
The MAXIMO series is a type of liquid chillers equip-ped with a built-in additional coil making Free Coo-ling using the outdoor air as cooling media.The free-cooling system installed on these chillers has been designed and applied by RC GROUP for the first time in the early 70’s and the today’s series is the result of more than 30 years experience.These chillers allow to achieve remarkable energy savings when installed in cold and temperate climate zones.
The components completeness together with the wide range of available optional accessories allow very quick and easy installation operations; the units simply need electrical and hydraulic connections.
104 RC GROUP SpA • C_GNR_0507
MAXIMO
MAXIMO.A.HD axial fans
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
550 600 660 770 880 990 1100 1210 1320 1420 1530 1640S2 S2 S2 S2 S2 S2 S2 S3 S3 S3 S3 S3
U10 U11 U11 U12 U13 U14 U14 W21 W21 W22 W22 W23476,6 544,9 579,5 681,2 770,2 889,7 957,3 1112,7 1186,3 1316,5 1390,6 1489,2355,9 442,4 446,8 522,4 611 703,9 712,2 988,4 999,3 1114,3 1124 1235,2
2 2 2 2 2 2 2 3 3 3 3 3157,1 170,3 186,8 217,8 246,8 278 309,4 337,3 370,1 401,5 432,7 459,1
2 2 2 2 2 2 2 3 3 3 3 35440 6500 6500 7860 8840 9310 9320 13650 13815 14890 14895 1582175 75 75 76 77 77 77 85 85 85 85 85
MAXIMO.A axial fans
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
21 25 32 37 50 61 36 42 50Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2G0 G0 G2 G2 G4 G4 G2 G2 G421,2 23,6 32,3 39 52,4 63 36,6 42,4 50,318 18,4 27,5 36 47,2 48,8 35,5 36,6 46,81 1 1 1 1 1 2 2 2
7,7 9,3 11,8 13 17,9 22,2 12,1 15,4 17,21 1 1 1 1 1 2 2 2
370 370 545 615 840 870 650 660 89062 62 62 64 64 64 64 64 64
TECHNICAL DATA AND NOMINAL PERFORMANCES
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
64 74 87 100 124 170 220 260 300Z2 Z2 Z2 Z2 Z2 Z2 F2 F2 F2G4 G6 G6 G6 G7 G7 G8 G8 G864,3 74,6 92,7 103,6 130,3 168,4 192,5 236,5 267,355 66,3 82,4 84,4 112,1 161,5 196,2 204,6 2092 2 2 2 2 2 2 2 2
23,4 26,5 29,4 35,3 43,6 50,9 63,3 76,1 93,82 2 2 2 2 2 2 2 2
940 1230 1380 1440 1740 2110 2465 2830 286065 65 66 66 66 67 68 74 74
(1) Referred to chilled water temperature 12/7°C / 20% glycol and air to the condenser at 35°C(2) Referred to water inlet temperature at 15°C / 20% glycol and outdoor temperature at 3°C
POWER SUPPLY: 400.3.50
(1) Referred to chilled water temperature 12/7°C / 20% glycol and air to the condenser at 35°C(2) Referred to water inlet temperature at 15°C / 20% glycol and outdoor temperature at 3°C
POWER SUPPLY: 400.3.50+N
air cooled liquid chillers with free-cooling system
105RC GROUP SpA • C_GNR_0507
MAXIMO
TECHNICAL DATA AND NOMINAL PERFORMANCES
MAXIMO.A.HD.ELN axial fans - extra low noise
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
550 600 660S2 S2 S2
U12 U12 U12491,3 536,3 569,2409,9 416,1 420
2 2 2153,8 172,1 188,7
2 2 27480 7660 766062 62 62
(1) Referred to chilled water temperature 12/7°C / 20% glycol and air to the condenser at 35°C(2) Referred to water inlet temperature at 15°C / 20% glycol and outdoor temperature at 3°C
POWER SUPPLY: 400.3.50
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
21 25 32 37 50 61 36 42 50Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2G2 G2 G4 G4 G5 G5 G4 G4 G522,1 24,6 32,4 38,6 53,2 62,6 36,3 43,3 50,822 22,5 28,7 35,3 50,5 51,9 34,9 39,5 50,11 1 1 1 1 1 2 2 2
7,3 8,7 11,7 13,2 17,4 22,4 12,3 15,1 16,61 1 1 1 1 1 2 2 2
545 545 750 800 1090 1095 890 910 108051 51 55 52 55 55 52 55 55
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
64 74 87 100 124 170 220 260 300Z2 Z2 Z2 Z2 Z2 Z2 F2 F2 F2G7 G7 G7 G7 G8 G8 G8 G9 G964,9 76,1 90,2 99,9 128 164,1 185,8 234,4 273,460,2 74,9 84,1 85,6 116,6 138,3 159,2 186,3 208,6
2 2 2 2 2 2 2 2 223,1 25,7 31 37 44,7 52,7 64,6 76,5 92,3
2 2 2 2 2 2 2 2 21430 1550 1650 1710 2070 2170 2465 4378 455451 55 51 51 53 53 56 58 61
MAXIMO.A.ELN axial fans - extra low noise
(1) Referred to chilled water temperature 12/7°C / 20% glycol and air to the condenser at 35°C(2) Referred to water inlet temperature at 15°C / 20% glycol and outdoor temperature at 3°C
POWER SUPPLY: 400.3.50+N
air cooled liquid chillers with free-cooling system
106 RC GROUP SpA • C_GNR_0507
MAXIMO
MAXIMO.SCREW.A axial fans
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
230 280 330 370 420 470 500 550 200 240 280 320V1 V1 V1 V1 V1 V1 V1 V1 V2 V2 V2 V2G8 G9 G9 G9 U10 U10 U10 U11 G8 G8 G9 G9
227,4 284,2 327,4 353,8 420 463,8 483,7 553,8 197 239,2 288,9 315,8189,7 241,1 242,2 244,9 350,8 354,3 356,7 447,7 187,6 191,2 241,8 245,4
1 1 1 1 1 1 1 1 2 2 2 280,5 92,3 114 131,2 140,9 156,1 170,4 208,3 77 100,1 98,4 118,9
1 1 1 1 1 1 1 1 2 2 2 22825 4255 4400 4420 4880 4900 5000 5800 2860 2870 4245 469071 72 72 72 74 74 74 74 72 72 73 73
TECHNICAL DATA AND NOMINAL PERFORMANCES
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
380 460 560 660 740 840 940 1000 1260 1410 1500 1650V2 V2 V2 V2 V2 V2 V2 V2 V3 V3 V3 V3
U10 U10 U11 U12 U12 U13 U14 U14 W21 W22 W23 W23384,5 457,4 536,2 638,9 714,9 829,8 929,5 977,1 1245,8 1371,5 1489,2 1675,6346 353,6 445,6 511,3 526,7 616,9 708,9 714,5 1011,4 1131,2 1245,8 1241,92 2 2 2 2 2 2 2 3 3 3 3
131,1 163,2 200 233,6 258,9 285,4 312,5 343,6 434,9 479,1 511,4 625,52 2 2 2 2 2 2 2 3 3 3 3
4860 4980 6150 7250 7600 8600 9390 10850 13830 15000 16100 1625075 75 75 76 76 77 77 77 84 84 84 84
MAXIMO.SCREW.A.ELN axial fans - extra low noise
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
230 280 330 370 420 470 500 550 200V1 V1 V1 V1 V1 V1 V1 V1 V2G9 G9 U10 U10 U11 U11 U12 U12 G8
234,8 270,4 329,5 360,9 423,4 459,6 498,4 558,5 188,4200,7 201,2 288,8 281,5 364,6 355,7 427,5 417,9 156,3
1 1 1 1 1 1 1 1 277,6 97,4 113,2 128,6 139,4 157,8 164,3 205,8 80
1 1 1 1 1 1 1 1 24315 4395 4830 4850 5400 5580 7050 7090 286059 59 61 61 61 61 61 61 55
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
240 280 320 380 460 560 660 740V2 V2 V2 V2 V2 V2 V2 V2G9 G9 U10 U10 U11 U12 U13 U14
251,1 274,8 324,5 367 452,5 541,3 639,1 722202,3 201,7 288 282,2 354,9 416,7 482,8 562,9
2 2 2 2 2 2 2 296,6 103,6 115,7 137,5 165 198,1 233,5 256,3
2 2 2 2 2 2 2 24360 4385 4840 4890 6000 7300 8100 885060 60 62 62 62 62 63 63
(1) Referred to chilled water temperature 12/7°C / 20% glycol and air to the condenser at 35°C(2) Referred to water inlet temperature at 15°C / 20% glycol and outdoor temperature at 3°C
POWER SUPPLY: 400.3.50
air cooled liquid chillers with free-cooling system
107RC GROUP SpA • C_GNR_0507
MAXIMO
TECHNICAL DATA AND NOMINAL PERFORMANCES
MAXIMO.SCREW.A.FLX axial fans
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
440 550 610 690 765 875 1010 1170V2 V2 V2 V2 V2 V2 V3 V3U9 U10 U10 U11 U11 U12 U14/13 U14/13
444,5 560,3 631,8 710,3 775,2 884 1043,1 1162,6310,8 420,2 423,1 522,8 532,9 626,9 732,8 771,8
2 2 2 2 2 2 3 3165,5 214,4 258 288,1 300,6 364 444,4 456,7
2 2 2 2 2 2 3 35483 6310 6810 7633 7748 9513 11375 1157575 76 76 77 77 77 77 77
MAXIMO.SCREW.A.XTR axial fans - extra low noise
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
465 585 640 725 815 940 1115V2 V2 V2 V2 V2 V2 V3
U10 U11 U11 U12 U13 U13 U14/13468,8 600,3 680,6 750,6 832,8 965,1 1102,7358,5 453,7 451,6 523,2 625,1 628,2 660,4
2 2 2 2 2 2 3155,1 197,4 235,8 266,2 275,5 328,1 415,4
2 2 2 2 2 2 36190 7033 7533 8450 9328 10276 1137563 64 64 64 65 65 65
(1) Referred to chilled water temperature 12/7°C / 20% glycol and air to the condenser at 35°C(2) Referred to water inlet temperature at 15°C / 20% glycol and outdoor temperature at 3°C
POWER SUPPLY: 400.3.50
air cooled liquid chillers with free-cooling system
108 RC GROUP SpA • C_GNR_0507
MAXIMO
MAXIMO.C centrifugal fans
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
21 25 32 37 50 61 36 42 50Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2 Z2G1 G1 G1 G3 G3 G3 G3 G3 G320,7 23,6 31,5 38,3 51,4 61,8 35,5 42,3 47,216,6 18,4 21,4 33,4 43,2 43,4 31,6 36,2 37,6
1 1 1 1 1 1 2 2 28 9,3 12,3 13,3 18,3 22,9 12,7 15,5 18,61 1 1 1 1 1 2 2 2
435 435 460 740 820 840 760 780 79059 59 66 60 68 68 59 60 64
TECHNICAL DATA AND NOMINAL PERFORMANCES
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
64 74 87 100 124 170 220 260 300Z2 Z2 Z2 Z2 Z2 Z2 F2 F2 F2G3 G5 G7 G7 G7 G7 G8 G8 G862,5 75,9 90,5 100,3 126,9 162,6 184,6 232,8 265,843,5 62,8 82 83,8 87,6 96,3 152,1 167,7 175,9
2 2 2 2 2 2 2 2 224,6 25,9 30,8 36,8 45,3 53,4 64,8 76,8 94,1
2 2 2 2 2 2 2 2 2880 1210 1630 1690 1730 1940 2760 3130 315568 70 69 69 69 71 75 77 78
(1) Referred to chilled water temperature 12/7°C / 20% glycol and air to the condenser at 35°C(2) Referred to water inlet temperature at 15°C / 20% glycol and outdoor temperature at 3°C
POWER SUPPLY: 400.3.50+N
MAXIMO.C.ELN centrifugal fans - extra low noise
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
21 25 32 37 50 61 36 42Z1 Z1 Z1 Z1 Z1 Z1 Z2 Z2G3 G3 G3 G5 G5 G5 G5 G521,6 24,6 31,9 39,1 52,4 63 36,3 42,620,1 22,5 26,2 37,1 47,2 48,8 34,9 37,7
1 1 1 1 1 1 2 27,5 8,7 12,1 12,9 17,9 22,2 12,3 15,41 1 1 1 1 1 2 2
660 660 690 980 1060 1070 1020 103048 50 53 52 60 60 51 52
MODEL
SizeCooling capacity (1) kWFree-cooling capacity (2) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (3) dB(A)
50 64 74 87 100 124 170 220Z2 Z2 Z2 Z2 Z2 Z2 Z2 F2G5 G5 G7 G8 G8 G8 G8 G848,6 63,8 75,1 92,4 103,1 126,4 160,3 187,442 48,9 68 105,1 107,7 112,1 124,2 1442 2 2 2 2 2 2 2
17,8 23,7 26,2 29,6 35,5 45,6 54,5 64,32 2 2 2 2 2 2 2
1040 1110 1450 2060 2120 2190 2250 270054 60 61 60 60 60 61 67
air cooled liquid chillers with free-cooling system
109RC GROUP SpA • C_GNR_0507
MAXIMO
b a
c
ba
c
DIMENSIONS (mm)
Size a b c
G0 1.150 1.100 1.640
G2 2.000 1.250 1.690
G4 2.600 1.410 1.690
G6 3.600 1.560 1.690
G7 3.600 1.560 2.215
G8 5.170 1.590 2.155
G9 5.900 1.723 2.470
MAXIMO.A / MAXIMO.SCREW.A / “G”
Size a b c
U9 4.510 2.385 2.430
U10 5.500 2.385 2.430
U11 6.490 2.385 2.430
U12 7.480 2.385 2.430
U13 8.470 2.385 2.430
U14/13 9.460 2.385 2.430
U14 9.460 2.385 2.430
MAXIMO.A / MAXIMO.SCREW.A / “U”
air cooled liquid chillers with free-cooling system
110 RC GROUP SpA • C_GNR_0507
MAXIMO
ba
c
ba
c
DIMENSIONS (mm)
Size a b c
G1 1.150 1.100 1.960
G3 2.000 1.250 2.010
G5 2.600 1.410 2.010
G7 3.600 1.560 2.010
G8 5.170 1.590 2.050
MAXIMO.C / “G”
Size a b c
W21 10.800 2.350 2.160
W22 11.870 2.350 2.160
W23 12.940 2.350 2.160
MAXIMO.SCREW.A / “W”
air cooled liquid chillers with free-cooling system
111RC GROUP SpA • C_GNR_0507
MULTIPLO_air cooled multifunction chillers
cooling capacity • 62,5 ÷ 626 kWheating capacity • 77,3 ÷ 816,9 kWcompressors • scroll / reciprocating / screwrefrigerant • R407C / R134aventilatori • axial / centrifugalmicroprocessor • MP99models • 41
112 RC GROUP SpA • C_GNR_0507
MULTIPLOair cooled multifunction chillers
MULTIPLO.A “G”
GENERAL FEATURES
The MULTIPLO liquid chillers are multifunction air cooled packaged units suitable for 4 pipe plants.Designed for air conditioning applications in any climatic zone, they are suitable for hotels, health centres, hospi-tals and for all those installations where the simultaneous production of cold and hot water is required.
The choice of their configuration is also multiple: screw and scroll type compressors, axial and centrifugal fans, R134a or R407C refrigerant.
VERSIONS :
MULTIPLO.A (R407C)
Cooling capacity 68,7 ÷ 271,3 kW
Heating capacity 82,3 ÷ 317,8 kW
Air cooled multifunction liquid chiller equipped with
scroll / reciprocating compressors and axial fans.
MULTIPLO.A.ELN (R407C)
Cooling capacity 63,8 ÷ 260,6 kW
Heating capacity 78,4 ÷ 363,9 kW
Extremely low noise air cooled multifunction liquid
chiller equipped with scroll / reciprocating compres-
sors and axial fans.
MULTIPLO.C (R407C)
Cooling capacity 63,8 ÷ 260,6 kW
Heating capacity 78,4 ÷ 363,9 kW
Air cooled multifunction liquid chiller equipped with
scroll / reciprocating compressors and centrifugal
fans.
MULTIPLO.C.ELN (R407C)
Cooling capacity 62,5 ÷ 255,7 kW
Heating capacity 77,3 ÷ 362,9 kW
Extremely low noise air cooled multifunction liquid
chiller equipped with scroll / reciprocating compres-
sors and centrifugal fans.
MULTIPLO.SCREW.A (R134a)
Cooling capacity 181,6 ÷ 626 kW
Heating capacity 214,8 ÷ 816,9 kW
Air cooled multifunction liquid chiller equipped with
screw compressors and axial fans.MULTIPLO.A “N”
113RC GROUP SpA • C_GNR_0507
MULTIPLOair cooled multifunction chillers
MAIN COMPONENTS
• Housing in anodised aluminium profile
frame. Panels in galvanized steel sheet
externally coated with PVC film
• Technical compartment separate from the
air flow
• Axial / centrifugal fans
• Scroll / reciprocating / screw compressors
• Welded plate or shell and tube evaporator
• Modulating condensing control
• Pump-Down stop system
• IDEA® defrosting system
• MP.99 microprocessor control system
• Electrical box in separate compartment
• Main switch with door lock safety
MULTIPLO.C “G”
MULTIPLO.A “U”
IDEA® defrosting system“Patented” defrosting system with dynamic reading of working parameters. Thanks to proprietary sof-tware it senses the real presence of brine on the coil starting defrosting cycles only in that situation. This brings a remarkable energy saving (more than 20-30% on the average) and a higher working con-tinuity compared with traditional systems.
MAIN OPTIONAL ACCESSORIES
• Pumping group
• Chilled water tank
• Hot water tank
• Water flow safety switch
• Serial port
114 RC GROUP SpA • C_GNR_0507
MULTIPLOair cooled multifunction chillers
TECHNICAL DATA AND NOMINAL PERFORMANCES
MULTIPLO.A axial fans
64 74 100 124 188 220 260 300Z2 Z2 Z2 Z2 F2 F2 F2 F2G6 G6 G8B G8B G8 G8 G8 G8
68,7 77,1 102,6 125 161,2 190,9 240,9 271,321,3 25,5 35,6 45,8 53,4 64,1 75,4 92,3
82,3 92,4 123,9 152,7 194,9 227,8 279,1 317,823 25,5 34,9 42,1 53 62,1 72,8 85,6
65,9 76,6 103,4 130,5 152,5 183,2 230,1 270,989,4 102,9 139,6 174,7 208,7 250,1 309,5 365,923,5 26,3 36,2 44,1 56,2 66,9 79,4 95
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
1060 1160 1485 1535 1950 2260 2600 265064 64 64 64 66 66 74 74
MODEL
SizeCOOLING (1)Cooling capacity kWPower input kWHEATING (2)Heating capacity kWPower input kWCOOLING + HEATING (3)Cooling capacity kWHeating capacity kWPower input kW
Compressors n.Gas circuits n.Weight kgSound pressure (4) dB(A)
MULTIPLO.A.ELN axial fans - extra low noise
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water temperature 40/45°C and outdoor temperature at 7°C(3) Referred to chilled water outlet temperature at 7°C and hot water outlet temperature at 45°C
POWER SUPPLY: 400.3.50+N
64 74 100 124 188 220 260 300Z2 Z2 Z2 Z2 F2 F2 F2 F2G6 G6 G8B G8B G8 G8 G8 G8
63,8 71,7 97,2 124,1 149 179,5 222,4 260,624,2 28,4 38,6 46,4 56 66,4 78,9 95,3
78,4 88,4 119,7 155,2 185,3 219,9 265,9 308,722,7 25,4 34,7 42,3 51,3 60,6 70,4 84,3
65,1 75,5 102,4 130,5 150,9 181,6 227,5 269,288,6 101,9 138,6 174,6 206,7 248,2 306,4 363,923,5 26,4 36,2 44,1 55,9 66,6 78,9 94,7
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
1060 1160 1485 1535 1950 2260 2600 265054 56 56 57 57 58 65 65
MODEL
SizeCOOLING (1)Cooling capacity kWPower input kWHEATING (2)Heating capacity kWPower input kWCOOLING + HEATING (3)Cooling capacity kWHeating capacity kWPower input kW
Compressors n.Gas circuits n.Weight kgSound pressure (4) dB(A)
115RC GROUP SpA • C_GNR_0507
MULTIPLOair cooled multifunction chillers
TECHNICAL DATA AND NOMINAL PERFORMANCES
MULTIPLO.C centrifugal fans
64 74 100 124 188 220 260 300Z2 Z2 Z2 Z2 F2 F2 F2 F2G7 G7 G8 G8 G8 G8 G8 G8
63,8 73,5 102,6 126,8 157,5 189,1 229 260,624,2 27,4 35,6 44,6 54,3 64,5 77,7 95,3
78,4 91,5 123,9 154,3 196,3 225,7 275,3 314,622,7 25,5 34,9 42,2 53,2 61,7 72 85,2
65,1 76 103,4 130,9 152,1 183 228,5 269,288,6 102,3 139,6 175 208,1 249,8 307,6 363,923,5 26,3 36,2 44,1 56,1 66,8 79,1 94,7
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
1400 1330 2065 2085 2480 2570 2960 300066 68 66 68 72 76 77 78
MODEL
SizeCOOLING (1)Cooling capacity kWPower input kWHEATING (2)Heating capacity kWPower input kWCOOLING + HEATING (3)Cooling capacity kWHeating capacity kWPower input kW
Compressors n.Gas circuits n.Weight kgSound pressure (4) dB(A)
MULTIPLO.C.ELN centrifugal fans - extra low noise
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water temperature 40/45°C and outdoor temperature at 7°C(3) Referred to chilled water outlet temperature at 7°C and hot water outlet temperature at 45°C
POWER SUPPLY: 400.3.50+N
64 74 100 124 188 220 260 300Z2 Z2 Z2 Z2 F2 F2 F2 F2G7 G7 G8 G8 G8 G8 G8 G8
62,5 71,9 97,3 125,7 148,3 178,5 219,3 255,725,2 28,3 38,5 45,3 56,2 66,6 79,4 96,2
77,3 90,4 119,7 156,6 189,2 218,1 268,5 311,322,7 25,5 34,7 42,4 51,9 60,3 70,8 84,7
64,9 75,7 102,4 130,8 150,8 181,4 227,1 268,488,4 102 138,6 174,9 206,6 248 305,8 362,923,5 26,3 36,2 44,1 55,8 66,5 78,8 94,5
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
1400 1330 2065 2085 2480 2570 2960 300064 66 58 62 64 69 72 74
MODEL
SizeCOOLING (1)Cooling capacity kWPower input kWHEATING (2)Heating capacity kWPower input kWCOOLING + HEATING (3)Cooling capacity kWHeating capacity kWPower input kW
Compressors n.Gas circuits n.Weight kgSound pressure (4) dB(A)
116 RC GROUP SpA • C_GNR_0507
MULTIPLO
ab
c
ab
c
air cooled multifunction chillers
TECHNICAL DATA AND NOMINAL PERFORMANCES
MULTIPLO.SCREW.A axial fans
180 220 260 320 360 410 480 545 625V2 V2 V2 V2 V2 V2 V2 V2 V2N8 N8 N9 U9 U9 U10 U10 U11 U12
181,6 219,1 262,4 320 357,8 413,8 480 546,2 62659,4 69,4 83,1 100,6 113,2 128,3 152,4 163,2 189,5
214,8 259,3 304,7 363,3 417 472,9 559,4 639,6 711,456,6 66 78,2 90,6 103,5 118,7 138,9 156,9 175,3
181,8 218,8 262,1 326,3 360,9 411,2 489,9 544 628,7241 288,2 345,3 424,1 472,5 540,6 637,6 708,4 816,959,2 69,4 83,1 97,7 111,6 129,4 147,7 164,4 188,2
2 2 2 2 2 2 2 2 22 2 2 2 2 2 2 2 2
1800 1860 2580 4308 4508 5040 5780 6348 700472 74 75 76 76 77 77 78 79
MODEL
SizeCOOLING (1)Cooling capacity kWPower input kWHEATING (2)Heating capacity kWPower input kWCOOLING + HEATING (3)Cooling capacity kWHeating capacity kWPower input kW
Compressors n.Gas circuits n.Weight kgSound pressure (4) dB(A)
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water temperature 40/45°C and outdoor temperature at 7°C(3) Referred to chilled water outlet temperature at 7°C and hot water outlet temperature at 45°C
POWER SUPPLY: 400.3.50
DIMENSIONS (mm)
Size a b c
G6 (axial) 3.600 1.290 1.690
G7 (centrifugal) 3.600 1.290 2.010
G8B (axial) 5.170 1.290 1.730
G8 (axial) 5.170 1.290 2.280
G8 (centrifugal) 5.170 1.290 2.050
Size a b c
N8 4.400 1.800 1.990
N9 5.400 1.800 1.990
U9 4.510 2.130 2.430
U10 5.500 2.130 2.430
U11 6.490 2.130 2.430
U12 7.480 2.130 2.430
117RC GROUP SpA • C_GNR_0507
TRILOGY_air cooled multifunction chillers
cooling capacity • 44,5 ÷ 148,8 kWheating capacity (heating) • 53,9 ÷ 207,1 kWheating capacity (sanitary) • 14,6 ÷ 209,2 kWcompressors • scrollrefrigerant • R410Aventilatori • axialmicroprocessor • MP.COMmodels • 18
118 RC GROUP SpA • C_GNR_0507
TRILOGYair cooled multifunction chillers
GENERAL FEATURES
TRILOGY, multifunction liquid chillers range produced with R410A refrigerant, represents the best solution for all those air conditioning applications requiring si-multaneous production of chilled water, hot water for heating and sanitary water all year long.Some of possible end-users are hotels, hospitals, offices, shopping centres.
First in its kind on the market, the TRILOGY multi-function chillers range features compact dimensions (the specific components for operating high pressures of the R410A refrigerant have reduced dimensions if compared to those applied for other refrigerants), low noise level, high energy saving, wide range of optional accessories.
TRILOGY
VERSIONS :
TRILOGY.BI (R410A)
Cooling capacity 44,5 ÷ 148,8 kW
Heating capacity 53,9 ÷ 186,6 kW
Reversible heat pump liquid chillers for 2 pipes plant.
On request partial or total heat reclaim system for
sanitary water production.
Heating capacity 14,6 ÷ 209,2 kW
TRILOGY.TETRA (R410A)
Cooling capacity 44,5 ÷ 155,5 kW
Heating capacity 53,9 ÷ 207,1 kW
Multifunction liquid chiller for simultaneous production
of chiller and hot water for 4 pipes plant.
On request partial heat reclaim system for sanitary
water production.
Heating capacity 14,6 ÷ 48,8 kW
TRILOGY.ESA (R410A)
Cooling capacity 44,5 ÷ 148,8 kW
Heating capacity (heating) 53,9 ÷ 207,1 kW
Heating capacity (sanitary) 53,9 ÷ 209,2 kW
Multifunction liquid chiller for simultaneous production
of chilled, hot and sanitary water, for 6 pipes plant.
119RC GROUP SpA • C_GNR_0507
TRILOGY
IDEA® defrosting system“Patented” defrosting system with dynamic reading of working parameters. Thanks to pro-prietary software it senses the real presence of brine on the coil starting defrosting cycles only in that situation. This brings a remarkable energy saving (more than 20-30% on the average) and a higher working continuity compared with tra-ditional systems.
MP.COMThe microprocessor control system MP.COM al-lows the units to communicate with all the standard protocols of the sector: MODBUS/JBUS, LON, TCP/IP, BACnet, TREND, GSM.
air cooled multifunction chillers
TRILOGYhydraulic connection side
MAIN COMPONENTS
• Housing in epoxy painted galvanized steel sheet.
• Scroll compressors
• Axial fans
• Welded plate gas/water heat exchangers in
AISI 316 stainless steel
• Water flow control through differential
pressure switch
• Pump-Down stop system
• IDEA® defrosting system
• MP.COM microprocessor control system
• Electrical box in separate compartment
• Main switch with door lock safety
MAIN OPTIONAL ACCESSORIES
• LNO kit for noise reduction
• Centrifugal pump in stainless steel for
chilled, hot and sanitary water
• Antifreeze electric heater for each
gas/water heat exchangers
• serial port
120 RC GROUP SpA • C_GNR_0507
TRILOGY
1 2 1 2 1 2 3 4 5
100%
100%
100%
100%
20% 20%
100% 100%
100% 100%
100% 100% 100%
1 2 3 1 2 3
100% 100% 100% 100%
100%100%100%100%
20% 20% 20%
1 2 3 4 5 6 7
100% 100% 100% 100%
100% 100% 100% 100%
100% 100% 100% 100%
air cooled multifunction chillers
WORKING LOGIC
TRILOGY.BIReversible heat pump. The production of sanitary hot water is made through partial or total heat reclaim systems and it matches the normal production of chilled or hot water according to the following schemes.In working condition no. 4 (simultaneous request of hot water for heating and sanitary water) the system gives priority to the sanitary water production. Only when the sanitary water request is satisfied, the system will start producing hot water for heating.
TRILOGY.TETRA Multifunction liquid chiller with simultaneous production of chilled and hot water. The production of sanitary hot water is made by the installation of a desuperheater (optional accessory) for the partial heat reclaim. The sanitary water is always produced regardless of the working request.
TRILOGY.ESA Multifunction liquid chiller with simultaneous production of chilled water, hot water and sanitary water.In working condition no. 4 and 7 the system gives priority to the sanitary water production. Only when the sanitary water request is satisfied, the system will start producing hot water for heating.
2 PIPE 2 PIPE+ Desupeheater
2 PIPE+ Condenser
4 PIPE 4 PIPE+ Desupeheater
6 PIPE
121RC GROUP SpA • C_GNR_0507
TRILOGY
TECHNICAL DATA AND NOMINAL PERFORMANCES
air cooled multifunction chillers
TRILOGY.BI 44 58 76 100 124 150Z2 Z2 Z2 Z2 Z2 Z2F1 F1 F2 F2 F3 F3
44,5 56,8 75,5 100,2 122,8 148,813,9 19,4 25 30,2 38,8 53,2
53,9 70,6 92,4 121,4 148,6 186,614,3 19,5 24,9 32,4 40,1 52
2 2 2 2 2 21 1 1 1 1 1
510 550 980 1110 1240 136068 69 68 73 74 74
14,6 18,6 24,8 32,9 40,3 48,8
53,9 71 92,7 121,8 149,4 187,6
58,4 77 101,4 130,2 162,9 209,2
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water outlet temperature 45°C and outdoor temperature at 7°C(3) Referred to chilled water temperature 12/7°C and hot water outlet temperature at 45°C(4) Referred to sanitary water temperature 40/45°C
POWER SUPPLY: 400.3.50+N
MODEL
SizeCOOLING (1)Cooling capacity kWPower input kWHEATING (2)Heating capacity kWPower input kWCompressors n.Gas circuits n.Weight kgSound pressure (6) dB(A)
OPTIONALSANITARY WATER (partial)Heating capacity (3) kWSANITARY WATER (total)sanitary water production onlyHeating capacity (4) kWcontemporary production of chilled water and sanitary waterHeating capacity (5) kW
TRILOGY.TETRA 44 58 76 100 124 150Z2 Z2 Z2 Z2 Z2 Z2F1 F1 F2 F2 F3 F3
44,5 56,8 75,5 100,2 122,8 148,813,9 19,4 25 30,2 38,8 53,2
53,9 71 92,7 121,8 149,4 187,613,9 18,9 24,2 31,6 39,3 50,6
44,1 57,5 76,1 97,9 122,3 155,558,3 76,6 100,9 130,2 162,3 207,1
2 2 2 2 2 21 1 1 1 1 1
510 550 980 1110 1240 136068 69 68 73 74 74
14,6 18,6 24,8 32,9 40,3 48,8
MODEL
SizeCOOLING (1)Cooling capacity kWPower input kWHEATING (2)Heating capacity kWPower input kWCOOLING + HEATING (3)Cooling capacity kWHeating capacity kWCompressors n.Gas circuits n.Weight kgSound pressure (5) dB(A)
OPTIONALSANITARY WATER (partial)Heating capacity (4) kW
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water outlet temperature 45°C and outdoor temperature at 7°C(3) Referred to sanitary water temperature 40/45°C(4) Referred to sanitary water temperature 40/45°C and outdoor temperature at 7°C(5) Referred to sanitary water temperature 40/45°C and chilled water outlet temperature at 7°C
POWER SUPPLY: 400.3.50+N
122 RC GROUP SpA • C_GNR_0507
TRILOGY
a b
c
air cooled multifunction chillers
DIMENSIONS (mm)
Size a b c
F1 1.750 950 1.800
F2 2.500 1.100 2.070
F3 2.500 1.100 2.490
TECHNICAL DATA AND NOMINAL PERFORMANCES
TRILOGY.ESA
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C(2) Referred to hot water temperature 40/45°C and outdoor temperature at 7°C(3) Referred to chilled water outlet temperature 7°C and hot water outlet temperature at 45°C(4) Referred to chilled water temperature 12/7°C and hot water temperature 40/ 45°C
POWER SUPPLY: 400.3.50+N
44 58 76 100 124 150Z2 Z2 Z2 Z2 Z2 Z2F1 F1 F2 F2 F3 F3
44,5 56,8 75,5 100,2 122,8 148,813,9 19,4 25 30,2 38,8 53,2
53,9 71 92,7 121,8 149,4 187,613,9 18,9 24,2 31,6 39,3 50,6
44,1 57,5 76,1 97,9 122,3 155,558,3 76,6 100,9 130,2 162,3 207,1
53,9 71 92,7 121,8 149,4 187,6
58,4 77 101,4 130,2 162,9 209,22 2 2 2 2 21 1 1 1 1 1
510 550 980 1110 1240 136068 69 68 73 74 74
MODEL
SizeCOOLING (1)Cooling capacity kWPower input kWHEATING (2)Heating capacity kWPower input kWCOOLING + HEATING (3)Cooling capacity kWHeating capacity kWSANITARY WATER (total)sanitary water production onlyHeating capacity (2) kWcontemporary production ofchilled water and sanitary waterHeating capacity (4) kWCompressors n.Gas circuits n.Weight kgSound pressure (5) dB(A)
123RC GROUP SpA • C_GNR_0507
COLDPACK_water cooled chillers / heat pumpsand condenserless chillers
cooling capacity • 32,2 ÷ 379,3 kWheating capacity • 29,5 ÷ 414,4 kWcompressors • scrollrefrigerant • R407Cmicroprocessor • MP.COMmodels • 88
124 RC GROUP SpA • C_GNR_0507
COLDPACKwater cooled chillers / heat pumps and condenserless chillers
GENERAL FEATURES
The range COLDPACK chillers allows to meet all air-conditioning requirements in residential, com-mercial and hi-tech applications, as well as in the tertiary sector.These machines are available in a full range of di-mensions, models and versions, with a rich variety of accessories and optional, so that they can become the ideal solution for installation in office buildings, public buildings, trade centres, industrial buildings, wine-cellars as well as for a variety of other applica-tions in the hi-tech and process sector.
Heavy-duty construction, thanks to their design and to the choice of materials and components, that reflect the policies followed for the machines meant for critical environments, where they are required to operate 365 days/year. In this way, continuous and regular operation of the machines is ensured under any load conditions.
VERSIONS :
COLDPACK.W (R407C)
Cooling capacity 32,2 ÷379,3 kW
Liquid chiller equipped with scroll compressor
and built-in water cooled condenser
COLDPACK.W.P (R407C)
Cooling capacity 27,8 ÷ 331,7 kW
Heating capacity 34,0 ÷ 414,4 kW
Heat pump liquid chiller equipped with scroll
compressor and built-in water cooled condenser.
COLDPACK.A (R407C)
Cooling capacity 28,6 ÷ 351,8 kW
Condenserless liquid chiller equipped with scroll
compressor for remote air cooled condenser
matching.
COLDPACK.A.P (R407C)
Cooling capacity 29,2 ÷ 358,4 kW
Heating capacity 29,5 ÷ 374,8 kW
Heat pump condenserless liquid chiller equipped
with scroll compressor for remote air cooled con-
denser matching.
COLDPACK
. In some capacity ranges, the machines are manufactured in two different versions:• with a single refrigeration circuit and several com
pressors in parallel. This version allows to achieve
mode (S version).
in line with the top levels of the market (D version).
125RC GROUP SpA • C_GNR_0507
COLDPACKwater cooled chillers / heat pumps and condenserless chillers
MAIN COMPONENTS
• Housing in epoxy painted galvanized steel
sheet
• Scroll compressors
• Welded plate evaporator
• Welded plate condenser
• Cycle reversing valve (heat pump)
• IDEA® defrosting system (heat pump)
• MP.COM microprocessor control
• Antifreeze system
• Water flow control by pressure switch
• Pump-Down stop system
• Electrical box in separate compartment
• Main switch with door lock safety
COLDPACKvista posteriore
IDEA® defrosting systemCOLDPACK.A.P version“Patented” defrosting system with dynamic reading of working parameters. Thanks to proprietary sof-tware it senses the real presence of brine on the coil starting defrosting cycles only in that situation. This brings a remarkable energy saving (more than 20-30% on the average) and a higher working con-tinuity compared with traditional systems.
MAIN OPTIONAL ACCESSORIES
• Water regulating valve (COLDPACK.W)
• Remote control panel
• Partial or total heat reclaim
• Serial port
• Remote air cooled condenser (COLDPACK.A)
Water/water heat pumpThe COLDPACK.W.P. version is a water cooled heat pump chiller, with reverse cycle on refrigerant. This proposal allows to avoid the inversion on the hydraulic circuit, making easy the installation and the water distribution.
Compact dimensions, limited weights, easytransport and handling to shorten installation time. Many models can be transported in common lifts
126 RC GROUP SpA • C_GNR_0507
COLDPACKwater cooled chillers / heat pumps and condenserless chillers
COLDPACK.W single circuit - water cooled
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
T.29 T.35 T.43 T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.200 T.260Z1 Z1 Z1 Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z3-S Z3-SJ4 J4 J5 J5 J5 J6 J6 J7 J7 J8 J8 J9
32,2 41,4 47,4 52 59,5 75,6 91,3 113,1 141,3 180,6 219,9 288,71 1 1 2 2 2 2 2 2 2 3 3
6,9 9,3 10,9 13 15,5 21,3 22,8 35,7 42,2 50,1 58,4 68,91 1 1 1 1 1 1 1 1 1 1 1
260 280 360 465 465 490 615 720 740 990 1150 125058 58 58 59 60 61 61 62 62,5 64 64 65
COLDPACK.W double circuit - water cooled
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.220 T.270 T.330Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z4-D Z4-D Z4-D
J5 J5 J6 J6 J7 J7 J8 J8 J9 J953,1 60,9 80,5 92,1 123,1 150,8 187,3 237,6 303,1 379,3
2 2 2 2 2 2 2 4 4 412,6 14,7 19,3 22,4 31,3 37,8 48 64,7 73,2 93
2 2 2 2 2 2 2 2 2 2500 500 525 650 760 780 1000 1030 1420 155059 60 61 61 62 62,5 64 65 65 65
(1) Referred to chilled water temperature 12/7°C and condenser water inlet temperature at 30°C
POWER SUPPLY: 400.3.50+N
TECHNICAL DATA AND NOMINAL PERFORMANCES
COLDPACK.A single circuit - air cooled - condenserless
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)Remote condenserTEAM.MATE DX.A 1 x
T.29 T.35 T.43 T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.200 T.260Z1 Z1 Z1 Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z3-S Z3-SJ4 J4 J5 J5 J5 J6 J6 J7 J7 J8 J8 J9
28,6 37,6 42,4 49,5 56,3 75 86,7 114,7 137,6 176,2 210,4 265,51 1 1 2 2 2 2 2 2 2 3 3
8,5 10,9 13,2 14 16,8 21,5 25 34,9 43,7 52,4 63 78,71 1 1 1 1 1 1 1 1 1 1 1
243 260 352 420 420 445 490 670 680 910 1060 114058 58 58 59 60 61 61 62 62,5 64 64 65
M.37 M.50 M.50 M.72 M.72 M.105 M.118 M.145 M.158 T.260 L T.260 D T.390 L
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C
POWER SUPPLY: 400.3.50+N
127RC GROUP SpA • C_GNR_0507
COLDPACKwater cooled chillers / heat pumps and condenserless chillers
COLDPACK.W.P single circuit - heat pump - water/water
MODEL
SizeCooling capacity (1) kWHeating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
T.29 T.35 T.43 T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.200 T.260Z1 Z1 Z1 Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z3-S Z3-SJ4 J4 J5 J5 J5 J6 J6 J7 J7 J8 J8 J9
27,8 36,2 41,3 45,0 51,5 66,1 79,7 98,8 122,4 156,7 192,2 253,034,0 44,5 51,1 56,9 65,6 85,8 100,3 131,3 161,2 202,8 245,8 313,7
1 1 1 2 2 2 2 2 2 2 3 38,4 11,3 13,2 15,6 18,4 25,4 27,2 41,2 49,4 59,5 69,8 81,28,7 11,7 13,6 16,2 19,0 26,3 28,1 42,6 51,0 61,5 72,1 83,91 1 1 1 1 1 1 1 1 1 1 1
260 280 360 465 465 490 615 720 740 990 1150 125058 58 58 59 60 61 61 62 62,5 64 64 65
COLDPACK.W.P double circuit - heat pump - water/water
MODEL
SizeCooling capacity (1) kWHeating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.220 T.270 T.330Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z4-D Z4-D Z4-D
J5 J5 J6 J6 J7 J7 J8 J8 J9 J946,0 52,6 70,1 80,0 107,4 131,8 163,8 206,3 266,5 331,757,4 66,1 87,7 100,4 135,5 165,9 206,4 266,0 332,3 414,1
2 2 2 2 2 2 2 4 4 415,2 17,8 23,4 27,0 37,0 44,9 56,2 77,2 87,6 109,515,8 18,4 24,1 27,9 38,3 46,4 58,1 79,8 90,5 113,1
2 2 2 2 2 2 2 2 2 2500 500 525 650 760 780 1000 1030 1420 155059 60 61 61 62 62,5 64 65 65 65
(1) Referred to chilled water temperature 12/7°C and condenser water inlet temperature at 30°C(2) Referred to hot water temperature 40/45°C and chilled water outlet temperature at 7°C
POWER SUPPLY: 400.3.50+N
TECHNICAL DATA AND NOMINAL PERFORMANCES
COLDPACK.A double circuit - air cooled - condenserless
MODEL
SizeCooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)Remote condenserTEAM.MATE DX.A 2 x
T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.220 T.270 T.330Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z4-D Z4-D Z4-D
J5 J5 J6 J6 J7 J7 J8 J8 J9 J948,6 56,3 75,1 83,7 116,7 144,2 177,5 227,3 290,1 351,8
2 2 2 2 2 2 2 4 4 414,8 16,8 21,9 26,3 34,1 40,4 52,1 69,6 79,3 104,8
2 2 2 2 2 2 2 2 2 2445 445 470 515 700 710 930 950 1310 142059 60 61 61 62 62,5 64 64 65 65
M.31 M.37 M.50 M.50 M.79 M.105 M.118 M.145 T.260 L T.260 L
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C
POWER SUPPLY: 400.3.50+N
128 RC GROUP SpA • C_GNR_0507
COLDPACK
ab
c
water cooled chillers / heat pumps and condenserless chillers
COLDPACK.A.P single circuit - heat pump - air cooled - condenserless
MODEL
SizeCooling capacity (1) kWHeating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
T.29 T.35 T.43 T.50 T.55 T.68 T.84 T.110 T.130 T.160Z1 Z1 Z1 Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z2-SJ4 J4 J5 J5 J5 J6 J6 J7 J7 J8
29,2 38,2 44,2 49,7 57,5 75,7 87,6 117,7 143,9 179,529,5 39,0 44,7 50,5 58,6 77,3 89,0 119,5 147,0 185,6
1 1 1 2 2 2 2 2 2 28,0 10,6 12,2 14,4 16,0 21,1 24,4 33,2 40,2 50,68,4 11,1 12,8 15,0 17,5 23,0 26,0 35,8 43,1 53,71 1 1 1 1 1 1 1 1 1
251 268 360 430 430 455 480 770 780 100058 58 58 59 60 61 61 62 62,5 64
COLDPACK.A.P double circuit - heat pump - air cooled - condenserless
MODEL
SizeCooling capacity (1) kWHeating capacity (2) kW Compressors n.Power input (1) kWPower input (2) kWGas circuits n.Weight kgSound pressure (3) dB(A)
T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.220 T.270 T.330Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z4-D Z4-D Z4-D
J5 J5 J6 J6 J7 J7 J8 J8 J9 J949,7 57,6 76,2 89,1 119,8 146,5 181,0 233,1 287,2 358,450,7 58,8 77,9 89,5 121,0 149,3 187,5 239,0 298,1 374,8
2 2 2 2 2 2 2 4 4 414,0 16,0 21,1 24,4 33,2 40,3 50,6 66,4 80,4 101,114,9 17,3 22,6 25,3 34,2 41,2 52,4 71,5 83,9 105,0
2 2 2 2 2 2 2 2 2 2445 445 470 515 700 710 930 950 1310 142059 60 61 61 62 62,5 64 64 65 65
(1) Referred to chilled water temperature 12/7°C and condensing temperature at 47,2°C(2) Referred to hot water inlet temperature 40°C and evaporating temperature at –5,2°C
POWER SUPPLY: 400.3.50+N
TECHNICAL DATA AND NOMINAL PERFORMANCES
DIMENSIONS (mm)
Size a b c
J4 1.000 650 1.400
J5 - J6 1.200 650 1.500
J7 1.200 750 1.700
J8 - J9 1.800 1.200 1.740
129RC GROUP SpA • C_GNR_0507
FRIGO_water cooled and condenserless chillers
cooling capacity • 127 ÷ 4138,7 kWcompressors • reciprocating / screw / centrifugalrefrigerant • R407C / R134amicroprocessor • MP.99 / MP.COMmodels • 136
130 RC GROUP SpA • C_GNR_0507
FRIGOwater cooled and condenserless chillers
MULTIPLICITY OF VERSIONS AND COMPONENTS
The wide range of cooling capacity, from 127kW to 4138 kW and the several available versions, allow the FRIGO chillers range the use of three different types of compressor.Indeed, they can be equipped with reciprocating, screw and centrifugal compressors, operating with shell and tube type evaporators.
LIQUID CHILLERS IN “A” ENERGY CLASS The FRIGO.TURBO series is characterized by its high
working conditions during the year, thanks to the special compressor installed in these units.
The FRIGO.TURBO liquid chillers are provided with an in-novative two-stage centrifugal compressor with motor shaft and impellers equipped with magnetic levitation bearings
to the traditional machines available in the market.First of all, the magnetic levitation bearings eliminate the presence of oil inside the compressor and consequently inside the refrigerant circuit, while the compressor electric motor is controlled by an inverter, obtaining a continuos cooling capacity variation from 10 to 100%.The cooling capacity is controlled also by the movable inlet guide vane system on the compressor’s suction port that diverts the angle of the gas entering the impeller as needed.This makes it possible to follow with considerable accuracy the trend of system thermal load.
The “K” version is designed for installation in parallel, to achieve high cooling capacity in reduced spaces with high silentness need.
VERSIONS :
FRIGO.W
Cooling capacity 337 ÷ 3444,5 kW (R407C)
Water cooled liquid chillers equipped with AMP re-
ciprocating compressors and built-in water cooled
condenser.
FRIGO.SCREW.W
Cooling capacity 127 ÷ 4138,7 kW (R407C)
Cooling capacity 258 ÷ 2795,8 kW (R134a)
Water cooled liquid chillers equipped with
screw compressors and built-in water
cooled condenser.
FRIGO.A
Cooling capacity 310 ÷ 3444,5 kW (R407C)
Cooling capacity 202,6 ÷ 1989,1 kW (R134a)
Condenserless water cooled liquid chillers equipped
with AMP reciprocating compressors.
FRIGO.TURBO.W
Cooling capacity 270 ÷ 1320 kW (R134a)
Water cooled liquid chillers equipped with magnetic
levitation two-stage centrifugal compressors and
built-in water cooled condenser.
FRIGO.SCREW.V2
131RC GROUP SpA • C_GNR_0507
FRIGOwater cooled and condenserless chillers
MAIN COMPONENTS
• Housing in thickness galvanized steel sheet
• Reciprocating / screw / centrifugal
compressors
• Welded plate evaporator / condenser
(FRIGO.TURBO.K)
• Shell and tube evaporator / condenser
• Pump-down stop system
• MP.99 / MP.COM microprocessor control
system
• Electrical box in separate compartment
• Main switch with door lock safety
FRIGO.S3
MAIN OPTIONAL ACCESSORIES
• Serial port
• Water regulating valve (version W)
• Partial heat reclaim
• 4 pipes heat exchangers for total heat re-
claim (FHR version)
• Water flow switch
• Compressors noise absorption cabinet
• Remote air cooled condenser (version A)
FRIGO.TURBO.K
FRIGO.TURBO
132 RC GROUP SpA • C_GNR_0507
FRIGOwater cooled and condenserless chillers
FRIGO.W water cooled
MODEL
Cooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
370 490 640 610 675 740 860 980 1100 1220 1350 1470S1 S1 S1 S2 S2 S2 S2 S2 S2 S2 S3 S3337 435,7 574,8 577,7 629,8 675,6 811 919,6 1037,9 1138,9 1264,2 1370,41 1 1 2 2 2 2 2 2 2 3 3
86,8 119,3 142 142,3 157,3 171,9 201,3 228,3 256,5 282,9 314,8 341,51 1 1 2 2 2 2 2 2 2 3 3
1910 2330 2518 2980 3100 3120 3480 3720 3900 4000 5200 523085 86 86 87 88 88 89 89 89 89 90 90
TECHNICAL DATA AND NOMINAL PERFORMANCES
MODEL
Cooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
1590 1710 1830 1960 2080 2200 2320 2440 2940 3180 3420 3660S3 S3 S3 S4 S4 S4 S4 S4 S6 S6 S6 S6
1515,9 1619,8 1722,3 1839,3 1957,7 2058,7 2177,8 2277,9 2740,7 3031,7 3239,5 3444,53 3 3 4 4 4 4 4 6 6 6 6
372,3 399,2 425,7 456,5 484,7 511,3 539,5 565,8 683 744,7 798,4 851,53 3 3 4 4 4 4 4 6 6 6 6
5520 5560 5600 7900 8100 8250 8350 8500 11520 12100 12390 1267090 90 90 91 91 91 91 91 91 91 92 92
FRIGO.SCREW.W water cooled
MODEL
Cooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
130 160 180 210 240 290 360 420 470 530 580 620 680V1 V1 V1 V1 V1 V1 V1 V1 V1 V1 V1 V1 V1127 160,4 178,2 200,1 239,6 288 349,5 409,8 463,3 506,5 567 602,7 694,31 1 1 1 1 1 1 1 1 1 1 1 1
29,3 36,6 39,4 47,3 52,2 66,1 77,9 92,8 103,7 113,4 122,7 137,7 167,51 1 1 1 1 1 1 1 1 1 1 1 1
1250 1275 1328 1430 1520 1750 1850 1985 2092 2360 2367 2575 275979 79 79 79 80 80 80 80 81 81 81 82 82
MODEL
Cooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
260 320 360 420 480 580 720 840 940 1060 1160 1240V2 V2 V2 V2 V2 V2 V2 V2 V2 V2 V2 V2
252,3 320,8 356,4 399,7 477,2 576,1 699,2 819,5 926,1 1020,9 1134,9 1201,62 2 2 2 2 2 2 2 2 2 2 2
58,9 74,2 79 94,6 104,2 132,3 155,5 185,7 207,6 227,9 245,8 274,82 2 2 2 2 2 2 2 2 2 2 2
1907 2030 2132 2500 2747 3051 3396 3665 3756 4370 4355 494682 82 83 83 83 84 84 85 85 85 85 85
MODEL
Cooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
1360 1590 1740 1860 2040 2320 2480 2720 3180 3480 3720 4080V2 V3 V3 V3 V3 V4 V4 V4 V6 V6 V6 V6
1385,8 1537,8 1710,2 1805 2069,4 2269,8 2402,9 2771,5 3075,6 3420,3 3610 4138,72 3 3 3 3 4 4 4 6 6 6 6
335,1 342,7 369,8 410,5 490,6 491,5 549,6 670,3 685,4 739,6 821 981,12 3 3 3 3 4 4 4 6 6 6 6
5150 6660 6636 7214 7576 8588 9522 10184 13190 13142 14298 1502285 87 87 87 87 85 85 85 87 87 87 87
(1) Referred to chilled water temperature 12/7°C and condenser water inlet temperature at 30°C
POWER SUPPLY: 400.3.50
133RC GROUP SpA • C_GNR_0507
FRIGOwater cooled and condenserless chillers
TECHNICAL DATA AND NOMINAL PERFORMANCES
FRIGO.SCREW.W water cooled
MODEL
Cooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
260 300 370 450 530 590 660 730 790V2 V2 V2 V2 V2 V2 V2 V2 V2258 299,9 369,5 453,9 528,3 588,7 660,3 728,4 792,32 2 2 2 2 2 2 2 2
57,5 65,4 79,4 92,7 113,5 124,2 135,4 149,1 159,42 2 2 2 2 2 2 2 2
2460 2495 2807 3037 3442 3527 4178 4328 449183 83 84 84 85 85 85 85 85
MODEL
Cooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
920 1050 1240 1400 1590 1840 2180 2340 2800V2 V2 V2 V3 V4 V4 V6 V6 V6
915,7 1056,4 1240,7 1397,9 1584,6 1831,3 2169,7 2337,7 2795,82 2 2 3 4 4 6 6 6
203,4 214 252,3 302,8 318,9 406,7 447 477,9 605,62 2 2 3 4 4 6 6 6
4830 5316 6482 7040 8862 9540 12864 13268 1395085 85 85 87 85 85 87 87 87
FRIGO.A air cooled - condenserless
MODEL
Cooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
370 490 640 610 675 740 860 980 1100 1220 1350 1470S1 S1 S1 S2 S2 S2 S2 S2 S2 S2 S3 S3310 418 518,3 520,7 571,2 617 732,7 828,7 933,7 1028,9 1142,1 1236,51 1 1 2 2 2 2 2 2 2 3 3
91,7 123,1 151,8 153,4 168,4 183 215,5 245,4 275,1 302,5 337,5 367,21 1 1 2 2 2 2 2 2 2 3 3
1765 2065 2117 2760 2862 2876 3260 3420 3560 3640 4750 469085 86 86 87 88 88 89 89 89 89 90 90
MODEL
Cooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
1590 1710 1830 1960 2080 2200 2320 2440 2940 3180 3420 3660S3 S3 S3 S4 S4 S4 S4 S4 S6 S6 S6 S6
1515,9 1619,8 1722,3 1839,3 1957,7 2058,7 2177,8 2277,9 2740,7 3031,7 3239,5 3444,53 3 3 4 4 4 4 4 6 6 6 6
372,3 399,2 425,7 456,5 484,7 511,3 539,5 565,8 683 744,7 798,4 851,53 3 3 4 4 4 4 4 6 6 6 6
5520 5560 5600 7900 8100 8250 8350 8500 11520 12100 12390 1267090 90 90 91 91 91 91 91 91 91 92 92
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C
POWER SUPPLY: 400.3.50
(1) Referred to chilled water temperature 12/7°C and condenser water inlet temperature at 30°C
POWER SUPPLY: 400.3.50
FRIGO.TURBO.W water cooled
MODEL
Cooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
K.240 K.270 250 300 500 600 750 900 1000 1200T1 T1 T1 T1 T2 T2 T3 T3 T4 T4270 310 270 330 540 660 810 990 1080 13201 1 1 1 2 2 3 3 4 4
57,3 69,1 55,6 70,4 109,1 142,6 167,5 212,2 222,2 281,51 1 1 1 2 2 1 1 2 2
1050 1120 1580 1750 2450 2700 3400 3800 4300 495055 55 74 74 77 77 78 78 79 79
134 RC GROUP SpA • C_GNR_0507
FRIGO
TECHNICAL DATA AND NOMINAL PERFORMANCES
ba
c
water cooled and condenserless chillers
(1) Referred to chilled water temperature 12/7°C and air to the condenser at 35°C
POWER SUPPLY: 400.3.50
FRIGO.A air cooled - condenserless
MODEL
Cooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
230 305 380 380 420 460 535 615 685 760 840 915S1 S1 S1 S2 S2 S2 S2 S2 S2 S2 S3 S3
202,6 268 354,1 339,6 373,3 404,1 471,6 533,4 606,7 666,5 736,6 798,21 1 1 2 2 2 2 2 2 2 3 3
58,2 77,5 96,2 96,3 106,4 116,3 136 154,6 176,2 196 213,1 231,71 1 1 2 2 2 2 2 2 2 3 3
1755 1965 2278 2726 2701 2715 3196 3351 3556 3638 4617 456285 86 86 87 88 88 89 89 89 89 90 90
MODEL
Cooling capacity (1) kW Compressors n.Power input (1) kWGas circuits n.Weight kgSound pressure (2) dB(A)
990 1070 1140 1225 1295 1370 1445 1520 1835 1980 2130 2280S3 S3 S3 S4 S4 S4 S4 S4 S6 S6 S6 S6
875,4 935,5 994,6 1066,7 1140,8 1200,8 1273,6 1333 1596,4 1750,8 1871 1989,13 3 3 4 4 4 4 4 6 6 6 6
253,7 273,5 293,2 309,2 330,8 350,4 372,2 392 463,3 507,4 546,9 586,53 3 3 4 4 4 4 4 6 6 6 6
4959 4981 5003 7054 7279 7411 7536 7668 10076 10870 11124 1136890 90 90 91 91 91 91 91 91 91 92 92
Model a b c
370 • 490 • 640 S1 3.000 1.100 1.980
610 • 675 • 740 S2 3.550 1.000 1.850
860 • 980 S2 3.550 1.300 2.000
1100 • 1220 S2 3.700 1.300 2.000
1350 • 1470 S3 4.890 1.430 2.150
1590 • 1710 • 1830 S3 4.890 1.550 2.000
1960 • 2080 • 2200 S4 3.550 2.360 1.850
2320 • 2440 S4 3.700 2.360 1.850
2940 S6 4.890 3.100 2.150
3180 • 3420 S6 4.890 3.220 2.000
3660 S6 4.890 3.220 2.150
FRIGO.W - FRIGO.A
DIMENSIONS (mm)
TECHNICAL DATA AND NOMINAL PERFORMANCES
135RC GROUP SpA • C_GNR_0507
FRIGO
b a
c
ba
c
water cooled and condenserless chillers
DIMENSIONS (mm)
Model a b c
230 • 305 • 380 S1 3.000 1.100 1.980
380 • 420 • 460 S2 3.550 1.000 1.850
535 • 615 S2 3.550 1.300 2.000
685 • 760 S2 3.700 1.300 2.000
840 • 915 • 990S3 4.890 1.430 2.150
1070 • 1140
1225 • 1295 • 1370 S4 3.550 2.360 1.850
1445 • 1520 S4 3.700 2.360 1.850
1835 • 1980S6 4.890 3.100 2.150
2130 • 2280
FRIGO.A
Model a b c
130 V1 2.065 1.100 1.776
160 • 180 • 210 V1 2.570 1.100 1.745
240 V1 2.870 1.100 1.745
290 V1 2.954 1.100 1.745
360 • 420 • 470 V1 2.977 1.100 1.875
530 • 580 V1 3.020 1.100 1.875
620 • 680 V1 3.020 1.100 1.980
260 • 320 V2 3.420 1.000 1.850
360 • 420 • 480 V2 3.620 1.000 1.850
580 V2 3.785 1.000 1.850
720 V2 3.800 1.180 1.973
840 • 940 V2 3.800 1.300 2.125
1060 V2 4.150 1.300 2.125
1160 V2 4.204 1.300 2.125
1240 • 1360 V2 4.150 1.300 2.125
1590 • 1740V3 5.100 1.860 2.335
1860 • 2040
2320 • 2480 • 2720 V4 4.150 2.360 2.125
3180 • 3480V6 5.100 2.360 2.335
3720 • 4080
FRIGO.SCREW.W
136 RC GROUP SpA • C_GNR_0507
FRIGO
b a
c
ab
c
a b
c
water cooled and condenserless chillers
DIMENSIONS (mm)
Model a b c
260 • 300 • 370 • 450 V2 3.620 1.000 1.850
530 V2 3.760 1.000 1.850
590 • 660 V2 3.800 1.180 1.973
730 • 790 • 920 V2 4.150 1.300 2.125
1050 V2 4.150 1.300 2.305
1240 V2 4.710 1.300 2.400
1.400 V3 5.135 1.860 2.200
1590 • 1840 V4 4.100 2.390 2.130
2180 • 2340 • 2800 V6 5.100 2.360 2.335
FRIGO.SCREW.W
Model a b c
250.T1 3.020 1.000 1.870
300.T1 3.020 1.000 1.870
500.T2 3.900 1.000 1.850
600.T2 3.900 1.000 1.850
750.T3 4.050 1.300 1.940
900.T3 4.050 1.300 1.940
1000.T4 4.120 1.625 2.070
1200.T4 5.130 1.625 2.070
FRIGO.TURBO
Model a b c
240.T1 1.000 1.300 1.850
270.T1 1.000 1.300 1.850
FRIGO.TURBO.K
137RC GROUP SpA • C_GNR_0507
TEAM.MATEair cooled condensers / dry coolers
condensers capacity • 8,2 ÷ 548,6 kWdry coolers capacity • 9,9 ÷ 386,5 kWfan type • axial / centrifugalmodels • 111
138 RC GROUP SpA • C_GNR_0507
TEAM.MATEair cooled condensers / dry coolers
AIR COOLED CONDENSERS
HORIZONTAL AIR FLOW
TEAM.MATE.DX.A
Nominal capacity 8,2 ÷ 156,8 kW
Air cooled condenser with axial fans.
TEAM.MATE.DX.A.STD
Nominal capacity 229 ÷ 665,5 kW
Air cooled condenser with axial fans.
TEAM.MATE.DX.A.ELN
Nominal capacity 198,4 ÷ 532,5 kW
Extremely low noise air cooled condenser with
axial fans.
TEAM.MATE.DX.C
Nominal capacity 11,1 ÷ 18,3 kW
Air cooled condenser with centrifugal fans.
TEAM.MATE.DX.C.STD
Nominal capacity 12 ÷ 140,3 kW
Air cooled condenser with centrifugal fans.
TEAM.MATE.DX.C.ELN
Nominal capacity 12 ÷ 140,3 kW
Extremely low noise air cooled condenser with
centrifugal fans.
GENERAL FEATURES
The air cooled condensers and the dry coolers of the TEAM.MATE series are specially designed for matching RC GROUP air conditioners and liquid chillers.
The TEAM. MATE range is available with three different noise solutions: D, L and extremely low noise ELN ver-sions. All these versions are directly selectable from the catalogue, to allow the possibility of installation even in presence of very severe acoustical impact norms.
TEAM.MATEcentrifugal fans
TEAM.MATEaxial fans
DRY COOLERS
HORIZONTAL AIR FLOW
TEAM.MATE.DC.A
Nominal capacity 15,3 ÷ 386,5 kW
Dry cooler with axial fans.
TEAM.MATE.DC.A.ELN
Nominal capacity 12,6 ÷ 308,7 kW
Extremely low noise dry cooler with axial fans.
TEAM.MATE.DC.C
Nominal capacity 12÷ 89,9 kW
Dry cooler with centrifugal fans.
TEAM.MATE.DC.C.ELN
Nominal capacity 9,9 ÷ 78,4 kW
Extremely low noise dry cooler with centrifugal
fans.
Centrifugal fansThe centrifugal fans allow the TEAM.MATE installation also inside offices with ducted air intake/exhaustion.
139RC GROUP SpA • C_GNR_0507
TEAM.MATEair cooled condensers / dry coolers
COMPONENTS DX.A.M• Housing in epoxy painted galvanized steel sheet
• Axial fans
• RIV1200 speed regulator for proportional
condensing control
• Stop valves on refrigerant connections
COMPONENTS DX.A.STD / ELN• Housing in epoxy painted galvanized steel
sheet
• Axial fans
• Insulated panels (ELN version)
OPTIONAL ACCESSORIES
• Stop valves on refrigerant connections
(DX.A.STD / ELN)
• Circuit breakers on each fan. In alternative
to circuit breakers a control electric box with
stepless condensing control (DX.A.STD / ELN)
COMPONENTS DX.C.M
Panels in galvanized steel sheet externally
• centrifugal fans
• RIV1200 speed regulator for proportional
condensing control
• Stop valves on refrigerant connections
COMPONENTS DX.C.STD / ELN
Panels in galvanized steel sheet externally
• Centrifugal fans
• Electrical box
• Stop valves on refrigerant connections
(up to T44 unit included)
• Insulated panels (ELN version)
OPTIONAL ACCESSORIES
• Condensing control system
• Stop valves on refrigerant connections
(from T57 unit)
COMPONENTS DC.C.STD / ELN
Panels in galvanized steel sheet externally
• Centrifugal fans
• Circuit breakers on each fan (up to T34 unit)
• Insulated panels (ELN version)
OPTIONAL ACCESSORIES
Circuit breakers on each fan (from T44 unit)
COMPONENTS DC.A.STD / ELN• Housing in epoxy painted galvanized
steel sheet
• Axial fans
• Circuit breakers on each fan
(up to M56 unit)
OPTIONAL ACCESSORIES
• Circuit breakers on each fan (from M83 unit)
140 RC GROUP SpA • C_GNR_0507
TEAM.MATEair cooled condensers / dry coolers
TEAM.MATE.DX.A axial fans
MODEL
Capacity (1) kW Weight kgSound pressure (2) dB(A)
M.10 M.18 M.22 M.31 M.37 M.50 M.72 M.79 M.88 M.105 M.118 M.145 M.158D D D D D D D D D D D D D
10,1 17,9 21,4 30,3 35,9 49,4 71,8 78,2 86,9 104,3 117,4 143,8 156,831 37 47 95 110 130 155 185 210 230 260 300 34057 59 58 67 67 66,2 69,2 69,2 70,5 70,5 70,5 69,5 69,5
TECHNICAL DATA AND NOMINAL PERFORMANCES / AIR COOLED CONDENSERS
MODEL
Capacity (1) kW Weight kgSound pressure (2) dB(A)
M.10 M.18 M.22 M.31 M.37 M.50 M.72 M.79 M.88 M.105 M.118 M.145 M.158L L L L L L L L L L L L L
8,2 13,4 16,4 24,1 27,5 38,4 55,4 58,3 70,1 81,9 87,5 110,8 116,931 37 47 95 110 130 155 185 210 230 260 300 340
49,3 51,3 50,3 59,3 59,3 58,5 61,5 61,5 62,8 62,8 62,8 61,8 61,8
POWER SUPPLY: 230.1.50
TEAM.MATE.DX.C.STD centrifugal fans
MODELWeight kgCapacity (1) kW Sound pressure (2) dB(A)
T.15 T.17 T.21 T.31 T.44 T.57 T.82 T.92 T.116 T.14070 75 85 140 170 295 320 340 460 560
14,2 16,9 20,9 30,8 44 57 82,2 91,9 115,6 140,368 70 65 72,5 78 74,7 79,2 80,2 83,2 85,2
POWER SUPPLY: 400.3.50+N
TEAM.MATE.DX.C.ELN centrifugal fans / extra low noise
MODELWeight kgCapacity (1) kW Sound pressure (2) dB(A)
T.15 T.17 T.21 T.31 T.44 T.57 T.82 T.92 T.116 T.14070 75 85 140 170 295 320 340 460 56012 14,1 17,6 25,9 37,2 48 69,7 77,3 97,3 118,661 63,5 58 64 69 65,7 71,2 72,2 76,2 78,2
POWER SUPPLY: 400.3.50+N
(1) Referred to condensing temperature at 50°C and outdoor air temperature at 35°C
TEAM.MATE.DX.A.STD axial fans
MODEL
Capacity (1) kW Weight kgSound pressure (2) dB(A)
T.260 T.260 T.390 T.390 T.520 T.520 T.640 T.640D L D L D L D L
269 228,7 404,5 343,9 540,1 459,3 665,5 548,6646 646 920 920 1196 1196 1580 158077 70 79 72 80 73 83 77
POWER SUPPLY: 400.3.50+N
POWER SUPPLY: 400.3.50+N
TEAM.MATE.DX.A.ELN axial fans / extra low noise
MODEL
Capacity (1) kW Weight kgSound pressure (2) dB(A)
T.260 T.260 T.390 T.390 T.520 T.520 T.640D L D L D L D
229 198,4 344,4 298,4 458 398,2 532,5646 646 920 920 1196 1196 158070 65 72 67 73 68 76
TEAM.MATE.DX.C centrifugal fans
MODEL
Capacity (1) kW Weight kgSound pressure (2) dB(A)
M.11 M.11 M.14 M.14 M.16 M.16 M.24 M.24D L D L D L D L
11,1 8,6 13,8 11 15,4 11,9 23,8 18,370 70 70 70 75 75 85 8565 57,3 68 60,3 68 60,3 65 57,3
POWER SUPPLY: 230.1.50
141RC GROUP SpA • C_GNR_0507
TEAM.MATEair cooled condensers / dry coolers
TECHNICAL DATA AND NOMINAL PERFORMANCES / DRY COOLERS
TEAM.MATE.DC.A axial fans
MODEL
Capacity (1) kW Weight kgSound pressure (2) dB(A)
M.20 M.26 M.36 M.56 M.83 M.113
15,3 19,8 26,8 42,3 62,2 85,795 110 130 185 260 34067 67 66,2 69,2 70,5 69,5
POWER SUPPLY: 230.1.50
(1) Referred to condensing temperature at 50°C and outdoor air temperature at 35°C
TEAM.MATE.DC.A.ELN axial fans / extra low noise
MODEL
Capacity (1) kW Weight kgSound pressure (2) dB(A)
M.20 M.26 M.36 M.56 M.83 M.113
12,6 16 21,9 34,4 51,1 69,895 110 130 185 260 34059 59 57,2 61,2 62,5 61,5
POWER SUPPLY: 230.1.50
TEAM.MATE.DC.C centrifugal fans
MODEL
Capacity (1) kW Weight kgSound pressure (2) dB(A)
T.16 T.23 T.34 T.44 T.63 T.86 T.119
12 17,6 25,6 32,8 47,6 65,2 89,980 135 163 287 310 450 55065 72,5 78 74,7 79,2 83,2 85,2
POWER SUPPLY: 400.3.50+N
TEAM.MATE.DC.C.ELN centrifugal fans / extra low noise
MODEL
Capacity (1) kW Weight kgSound pressure (2) dB(A)
T.16 T.23 T.34 T.44 T.63 T.86 T.119
9,9 14,7 21,3 27,2 39,8 54,8 74,880 135 163 287 310 450 55058 64 69 65,7 71,2 76,2 78,2
POWER SUPPLY: 400.3.50+N
TEAM.MATE.DC.A axial fans
MODEL
Capacity (1) kW Weight kgSound pressure (2) dB(A)
T.170 T.170 T.250 T.250 T.340 T.340 T.410 T.410D L D L D L D L
163,8 119,9 248,2 199,9 330,2 270,3 386,5 313600 600 820 820 1063 1063 1410 141077 70 79 72 80 73 83 77
POWER SUPPLY: 400.3.50+N
TEAM.MATE.DC.A.ELN axial fans / extra low noise
MODEL
Capacity (1) kW Weight kgSound pressure (2) dB(A)
T.170 T.170 T.250 T.250 T.340 T.340 T.410 T.410D L D L D L D L
135,8 114,2 214,4 172,1 273,8 228,8 308,7 223,7600 600 820 820 1063 1063 1410 141070 65 72 67 73 68 76 68
POWER SUPPLY: 400.3.50+N
142 RC GROUP SpA • C_GNR_0507
TEAM.MATE
ab
c
a b
c
DIMENSIONS (mm)
TEAM.MATE.DX.A
Model a b c
M.10 / M.18 855 482 726
M.22 1.155 482 726
M.31 / M.37 1.355 620 1.026
M.50 1.555 620 1.026
M.72 / M.79 2.500 630 1.135
M.88 / M.105 / M.118 3.580 630 1.135
M.145 / M.158 4.660 630 1.135
T.260 4.225 820 2.255
T.390 5.975 820 2.290
T.520 7.725 820 2.290
T.640 9.475 820 2.290
TEAM.MATE.DC.A
Model a b c
M.20 / M.26 1.355 620 1.070
M.36 1.555 620 1.070
M.56 2.500 658 1.135
M.83 3.580 658 1.135
M.113 4.660 658 1.135
T.170 4.225 820 2.255
T.250 5.975 820 2.290
T.340 7.725 820 2.290
T.410 9.475 820 2.290
TEAM.MATE.DX.C TEAM.MATE.DC.C
Model Model a b c
M.11 / M.14 / M.16 -- 930 850 690
M.24 -- 1.270 930 970
T.15 / T.17 -- 930 850 690
T.21 T.16 1.050 930 820
T.31 T.23 1.270 930 970
T.44 T.34 1.550 1.100 1.040
T.57 T.44 1.850 1.000 1.190
T.82 / T.92 T.63 2.200 1.180 1.230
T.116 T.86 2.700 1.400 1.540
T.140 T.119 2.700 1.500 1.750
air cooled condensers / dry coolers
143RC GROUP SpA • C_GNR_0507
THERMOFRIGO_water cooled absorption chillers (LiBr)
cooling capacity • 75 ÷ 4928 kWrefrigerant • Water and Lithium-Bromide (LiBr) solutionheat source • hot water / steam / gasversions • single / double effect
144 RC GROUP SpA • C_GNR_0507
THERMOFRIGOwater cooled absorption chillers (LiBr)
single effect cycle
The heat source for single effect units can be hot water, from 75 up to 150°C, or steam with pressure
from 50 up to 300 kPa.
Hot water heat sourceTHERMOFRIGO.W.COG
Cooling capacity 176 ÷ 282 kW
THERMOFRIGO.W.LTE
Cooling capacity 352 ÷ 2288 kW
THERMOFRIGO.W.MTE
Cooling capacity 310 ÷ 4928 kW
Steam heat sourceTHERMOFRIGO.S.SEF
Cooling capacity 176 ÷ 4914 kW
double effect cycle
The heat source for double effect units can be hot water, from 150 up to 200°C, steam with pressure from 400 up to 1.000 kPa or gas.
Hot water heat sourceTHERMOFRIGO.W.HTE
Cooling capacity 317 ÷ 4875 kW
Steam heat sourceTHERMOFRIGO.S.DEF
Cooling capacity 176 ÷ 4914 kW
Methane gas heat sourceTHERMOFRIGO.G.MOD
Cooling capacity 134 ÷ 261 kW
Heating capacity 107 ÷ 201 kW
THERMOFRIGO.G.HEF
Cooling capacity 352 ÷ 1936 kW
Heating capacity 321 ÷ 1774 kW
145RC GROUP SpA • C_GNR_0507
THERMOFRIGO
WHAT IS AN ABSORPTION CHILLER?
An absorption chiller is a thermal machine that uses heat to produce cooling energy.
Generally speaking, an absorption chiller can be properly used everywhere chilled water is required and at the same time waste heat is available or electric power is not available or not economically convenient.
APPLICATIONS
COGENERATIONLow temperature heat produced by reciprocating engines is practically not useful during summer mon-ths. It can be recovered and used to run an absorp-tion chiller, so that it is possible to produce cooling power in these months.Also exhaust gases coming from a gas turbine can be recovered to produce steam or hot water and run an absorption chiller.
DISTRICT HEATINGDistrict heating networks use the heat recovered from the electric energy production plants or by wa-ste thermal incinerator plants.During the winter the heat produced by the district heating network is used to heat the building. During the summer it can be used for the building cooling by means of hot water fired absorption units con-nected to the network.
HEAT RECOVERYWhere waste heat is available, as for example in ho-spitals or industrials processes, it can be economi-cally convenient to use absorption chillers (hot water or steam fired).There are a lot of industrial processes that have ideal conditions for the use of absorption chillers: waste heat available and cooling required (printing, pharmaceutical, chemical, automotive, food, textile, biotech, electronics....).
INFORMATION TECHNOLOGY APPLICATIONSThe information technology application operate in me-dium and big size plants located in city centres to be as close as possible to the users and where the reque-sted cooling capacity is very high (1.500/3.000 W/m2).
Nowadays most of the cities have no availability of the electric energy that this type of plant needs. The self-production of electric energy will be necessary with cogeneration systems.The energetic balance (in terms of electric and cooling energy required) of an Information Technology building is equal to an engine powered cogeneration system
of electric and cooling energy released).
water cooled absorption chillers (LiBr)
146 RC GROUP SpA • C_GNR_0507
THERMOFRIGOwater cooled absorption chillers (LiBr)
GENERAL FEATURES
• No vibrations• Minimum quantity of electric power required• Low operating costs• Low maintenance costs• High reliability• Good performance at part load: stepless
from 10% to 100%.
USEFUL HEAT SOURCES
Absorption chillers can be used with different heat sources:• hot water (from 75°C to 200°C)• steam (from 50 to 1.000 kPa)• exhaust gas• direct combustion of fuel (gas for example)
THERMAL COMPRESSION MECHANICAL COMPRESSION
Thermal compression vs. mechanical compression
In a conventional, mechanical vapour compression cycle, the refrigerant evaporates at a low pressure producing the cooling effect.It is then compressed in a mechanical compressor to a higher pressure, where it condenses. In most of the ma-chines in the market, the compressor is normally powered by an electric motor.In an absorption chiller the evaporator and condenser are essentially the same, but a chemical absorber and a thermal generator replace the compressor, with a pump to provide pressure change.In this absorber the refrigerant generated in the evaporator is absorbed into liquid state. Then, thanks to the pump and to the thermal generator, the pressure difference is obtained and the refrigerant is transformed into vapour state again, before entering the condenser.
EFFICIENCY
Depending on heat source available temperature, two differenttypes of machines can be used:• single effect type – efficiency up to 0.8• double effect type – efficiency up to 1.1
Co
mp
ress
or
Condenser
EvaporatorEvaporator
CondenserGenerator
Heatexchanger
Absorber
The
rmal
ene
rgy
Ele
ctri
c en
erg
y
147RC GROUP SpA • C_GNR_0507
ICE.BANK_thermal storage system with LEVLOAD system
storage capacity • 170 ÷ 670 kW/hmodels • 5
148 RC GROUP SpA • C_GNR_0507
ICE.BANKthermal storage system with LEVLOAD system
THERMAL STORAGE SYSTEMS
ICE.BANK.LEVLOAD
Total storage capacity 170 ÷ 670 kWh
GENERAL FEATURES
Air conditioning is the largest single contributor to power plants and lines electrical “peak demand” charges, especially during summer daytime hours.After noon, as more air conditioners are needed to maintain comfortable temperatures, the increased demand for electricity adds to that already created by lighting, operating equipment, computers and thousand of others uses.This require the utility to bring additional, more co-stly generating sources on line to handle its increa-sed demand.Commercial users whose large air conditioning loads contribute to these added generating requirements are assessed an additional charge based on their highest on-peak demand for electricity.A Stored Cooling System is either a load-shifting or load-levelling method which will significantly lower demand charges during the air conditioning season and, consequently, energy costs.It uses a standard packaged chiller to produce solid ice at night during off-peak periods when the buil-ding’s electrical needs are at the minimum.The ice is built and stored in modular ice tanks du-ring the night to provide needed cooling capacity to
meet the building’s air conditioning load requirement the following day.Making ice at night and using its stored energy du-ring the day is not a new or experimental idea.This concept had been employed for years in coo-ling short-peak applications such as cinemas and theatres.Now there is renewed interest in a board use of ice-making systems by both users and utilities as the best way to offset rising operating costs.In fact, Stored Cooling Systems are what summer-peaking utilities must have to avoid the unbeara-ble costs of new generating plants. This allows a remarkable reduction of the management costs, taking advantage of the differentiate tariffs for the electricity consumption, applied by the local Energy Suppliers Body.Furthermore, in the modern air conditioning plan-ts in Hi- Tech. applications, telephone exchanges and special plants, it is always more important and sometimes necessary, to realize backup system al-lowing working continuity in case of lack of energy.The Stored Cooling Systems are able to efficaciou-sly help to solve the problem.ICE.BANK with LEVLOAD system is the new ther-mal storage system for air conditioning plants pro-posed by RC GROUP.The system is easy to install, it is valid either for new or old air conditioning plants.Today, more than 10.000 ICE.BANK LEVLOAD sy-stems are storing 6 million kWh thermal energy in the word.
149RC GROUP SpA • C_GNR_0507
ICE.BANKthermal storage system with LEVLOAD system
MAIN COMPONENTS
• Polyethylene tank
• 50m insulation tank
• Aluminium outer skin
• Insulated rubber cover
• Heat exchanger in special plastic material
• Insulated rubber base
REFRIGERANT
GLYCOL SOLUTIONSOLID ICE
MELTED ICE AREA
GLYCOL SOLUTION
FLOW DIRECTION
MELTED ICE AREA
SOLID ICE
ICEBUILDER
ICE.BANKLEVLOAD
WHAT IS ICE.BANK LEVLOAD?
The ICE.BANK is a modular, insulated polyethyle-ne tank containing a spiral-wound plastic tube heat exchanger surrounded with water.The ice is built uniformly throughout the tank by the patent temperature averaging effect of closely spaced
Water does not become surrounded by ice during the freezing process and can move freely as ice forms, preventing stress or damage to the tank.Since now, direct expansion ice storage systems have been employed, where ice is frozen directly on metal refrigerant tubes and immersed in a water tank. This system is named “ice builder”.The water in the tank surrounding the ice is then pum-ped to the cooling load.The drawing compares the ICE.BANK method of bur-noff (ice melting) with the old-style ice builder.Notice that the ice builder melts from the outside-in while the ICE.BANK melts from the inside-out.During the next charging cycle, the ICE.BANK will be able to refreeze quickly while the ice builder must overcome the insulating effect of the ice remaining on its coils.Unlike the ICE.BANK, the ice builder requires ice thick-ness controls to prevent total freeze-up which would completely shut down the system.The ice builder is also subject to uneven burn-off
thermal capacity
MAIN OPTIONAL ACCESSORIES
• Ice level control sensor
• Flexible hydraulic connections
• Burying system
150 RC GROUP SpA • C_GNR_0507
ICE.BANK
a
c
thermal storage system with LEVLOAD system
ICE.BANKMODEL
Capacity kW/h Empty weight kgWorking weight kg
1045 1082 1098 1105 1190
170 341 405 436 670182 465 556 578 885
1760 3835 4581 4880 7605
TECHNICAL DATA AND NOMINAL PERFORMANCES
DIMENSIONS (mm)
Model a ø c
1045 1.880 1.117
1082 1.880 2.083
1098 2.262 1.730
1105 1.880 2.565
1190 2.262 2.565
152 RC GROUP SpA • C_GNR_0507
MP.
MP.99 MICROPROCESSOR CONTROLThe MP99 microprocessor control system has been designed and produced by RC GROUP to control its medium and high capacity liquid chillers and heat pumps.
With MP99, the PROACTIVE logic originates, e.g. the capacity to protect the unit com-ponents granting operation stability even in emergency situations. The system can be expanded to increase the performances and to communicate with supervision systems.Other peculiarities are: double set-point with external command variation, pumps control and IDEA® defrosting system.
Functions:• Control up to 4 compressors on 4 independent circuits• Heat pump• Free-Cooling• Total heat reclaim• Single language management (English)
Supervision:• Protocol RC Standard (Johnson, Siemens, Plantwatch)• Gateway MODBUS, JBUS• Supervise RC
MICROCHILLER MICROPROCESSOR CONTROLThe small MICROCHILLER microprocessor is used by RC GROUP for its small capacity liquid chillers and heat pumps management.
Functions:• Control up to 2 compressors on 2 independent circuits• Heat pump• Communication through sysmbols
Supervision:• RS485 serial port
MP.COMxs MICROPROCESSOR CONTROLThe MP.COMxs microprocessor is used by RC GROUP for its air conditioners for Telecommunication applications management.
Functions:• Control for 1 compressor• Chilled water• Multilanguage• Remote terminal
Supervision:• MODBUS, JBUS, Plantwatch direct connection• GSM• TCP/IP• LAN up to 7 units with remote terminal
microprocessor control systems
153RC GROUP SpA • C_GNR_0507
MP.
MP.2000.Graphic MICROPROCESSOR CONTROLThe MP.2000 Graphic microprocessor is used by RC GROUP to control its air conditioners and heat pumps.Specially designed for air conditioners, MP.2000.Graphic is characterized by the possibility of LAN connection, remo-tizable display, IDEA®
the air conditioners.
Functions:• Control up to 2 compressors on independent circuits• Chilled water
• Additional coil (heating, Extra-Circuit, Free-Cooling (water))• Multilanguage / Graphic display
Supervision:• MODBUS, JBUS, Plantwatch direct connection• GSM• TREND, BACNET• LAN up to 4 units with remote terminal• Change Over for 4 units
MP.COM MICROPROCESSOR CONTROLThe MP.COM microprocessor is used by RC GROUP to control its air conditioners and liquid chillers including heat pumps.MP.Com is characterized by the use of the IDEA® defrosting logic in heat pump versions and by the Autoadapive logic for automatic setting of the control parameters. This replaces human subjectivity with microprocessor objectivity, which
and with a Data Logger, with black box, for a correct analysis of the malfunction causes.
Version for Liquid ChillersFunctions:• Cooling• Heat pump• Total heat reclaim• Multifunction• Free-cooling• Stepless cooling capacity control for screw compressors• Multilanguage / Graphic display
• Scroll / Screw compressors• 1 / 2 / 3 refrigerant circuits• Control up to 6 compressors, 3 compressors in parallel on each circuit
Supervision:• MODBUS, JBUS, Plantwatch direct connection• TREND, BACNET• GSM• Connection to other system through Gateway• LAN up to 7 units
microprocessor control systems
154 RC GROUP SpA • C_GNR_0507
MP.
MP.COM MICROPROCESSOR CONTROL
Version for Air ConditionersFunctions:
• Thermal condition contol for Displacement unit• Direct FreeCooling (air) with humidity control (Displacement unit)
• Additional coil (heating, Extra-Circuit, Free-Cooling (Water))• Multilanguage / Graphic display
• Scroll compressors• 1 / 2 refrigerant circuits• Chilled water
Supervision:• MODBUS, JBUS, Plantwatch direct connection• GSM• LON, TREND, BACNET• TCP/IP• LAN up to 14 units• Change Over for 6 units
microprocessor control systems