CHEMISTRY LABORATORY
SAFETY ORIENTATION
![Page 2: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/2.jpg)
Eye protection, gloves & lab coats
• Goggles required for all classes• ANSI Z87.1, non vented• Sold by Chem. Office at the beginning of each
quarter• Gloves – provided by the Department for all
classes and research labs• Type: vinyl, non-powdered; for Organic classes:
Nitrile.• Laboratory coats required in all classes and
available in SU Bookstore ( ~$27.00, XL $31.50)
![Page 3: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/3.jpg)
![Page 4: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/4.jpg)
![Page 5: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/5.jpg)
First Aid Kits locations:
• Stockrooms 514 & 609• Quant Lab. 507 (between 507 and 506)• Organic Lab 603• Main Chemistry Office: 516• All research labs
![Page 6: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/6.jpg)
EMERGENCY PROCEDURES• Chemical burns: wash affected body parts with
cold water for 15 minutes; • Exceptions: HF, Na, K, Phosphorous (see CHP
for specific instructions)• Do not attempt to neutralize!!!!• Organic burns – use hand soap to emulsify
organic substance, wash w/water• Eyes: wash w/water for 15 minutes in eye wash
fountain• Evaluate the burns and sent a victim to the
Health Center
![Page 7: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/7.jpg)
CAMPUS HEALTH CENTER:
• Located in Bellarmine Hall• Phone # (206) 296-6300• Open Mon- Fri 7:00-5:00• When closed – go to Swedish, Providence or
Harborview Emergency Departments• Telephone ##: Swedish 386-2573; Providence: 320-2111; Harborview: 731-3074 • Telephones located in the 5-th and 6-th floor
hallways, room BA601and Stockroom BA609
![Page 8: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/8.jpg)
LIFE THREATENNING CONDITIONS
• Difficulty breathing• Major injuries: open wounds, spinal or
neck, obvious fracture..etc.• Unconsciousness or unresponsiveness• SU Emergency line # -5911
![Page 9: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/9.jpg)
EVACUATION ROUTES
• Always use stairs, check reassembly areas assigned to different buildings on campus
• BANNAN in front of the Law School flag pole (picture)
• There will be an “evacuation drill” some times during the school year.
![Page 10: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/10.jpg)
Evacuation assembly area for Bannan building: by the Law School flagpole
![Page 11: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/11.jpg)
Evacuation procedure:• Stop what you are doing and walk, not run, to the
nearest stairwell. Close all doors behind you.• Use the stairs, do not use elevators. If the powers fails,
you may become trapped in the elevator.• Once evacuated, proceed to your designated gathering
area. Do so in an orderly manner, do not panic.• In assembly area report to your instructor/supervisor fr a
headcount.• Do not re-enter the building until the “all clear”
announcement is given by the emergency coordinator.
•
![Page 12: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/12.jpg)
FIRE HAZARD
• Each lab is equipped with ABC extinguisher, located by the door and labeled
• In case of the fire not possible to handle with the extinguisher– activate the fire alarms and evacuate!!
• Fire alarms are located at the opposite sides of each hallway (picture)
![Page 13: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/13.jpg)
Fire alarm next to BA501
![Page 14: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/14.jpg)
INCIDENT/ ACCIDENT REPORTS
• Fill up a “Chemistry Department Incident Report Form” – available in each laboratory. Give one copy to Kasia, keep one. We will archive them on SU Network and eventually use for safety discussion.
• Accidents as: injuries, fires and spills should also be reported to Public Safety.
![Page 15: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/15.jpg)
![Page 16: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/16.jpg)
![Page 17: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/17.jpg)
“Reportable Accidents”
• Each injury, fire and “spill” in the laboratory should be reported to Public Safety Department in order to make an official “Accident Report”
• Call -5990 or –5911• The officers will show up in the lab to fill
out the required forms
![Page 18: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/18.jpg)
CHEMICAL SPILLS
• Immediate action: confine and neutralize if possible to handle.
• Examples of spills which would require evacuation:
• - Bromine> 50 ml and not in the hood -Mercury > 1 thermometer bulb
-Extremely hazardous chemicals > 1 L.Call Public Safety Office at -5911, they will contact
Emergence Response Team to clean up the lab.
![Page 19: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/19.jpg)
WORKING WITH CHEMICALS
![Page 20: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/20.jpg)
ORDERING, INVENTORY & STORAGE
• Monthly PO# ( ask Doris)
• The chemicals will be delivered to the Stockroom, inventoried and delivered to you
• Inventory : bar-coded system by VERTERE• Kasia & Deanna are “administrators” eligible to make
entries/changes• “Read only” copy – available in T drive under “Chemical
and lab inventories”• No password required• To remove used reagents from inventory list: return an
empty bottle with bar-code label to the Stockroom or remove the label and stick on the designated log.
![Page 21: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/21.jpg)
CHEMICAL STORAGE LOCATIONS:
• BA610 – main chemical storage area• BA605&604 under hoods: Corrosive acids and bases• BA603 under hoods: Hexanes, Ethyl Acetate,
Halogenated solvents• Research chemicals: in individual research labs and
BA612/B ( solvent purification room) • BA514 Stockroom: limited amounts of basic chemicals
for lecture demonstrations• Teaching labs: limited amount of chemicals for students’
experiments
![Page 22: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/22.jpg)
Relocation procedures:
• Sign relocations sheet ( on the door of storage areas)
• Needed are: date, bar-code number & new location
• This is to keep the inventory updated
![Page 23: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/23.jpg)
Barcode Number New Location (Room #) Your professor’s name
Chemical Relocation LogPlease add the following information when removing any chemical reagent from this lab.
![Page 24: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/24.jpg)
Please, remove barcodes from empty reagent bottles and stick them here:
![Page 25: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/25.jpg)
CHEMICALS “WATCH LIST”• 1. Reagents (air contaminants) with extremely low (OSHA) PEL-s: • -Acrylamide 0.3 mg/cu meter• -Allyl alcohol 5 mg/ “• -Benzene 1 ppm• -Benzyl chloride 5 mg• -Bromine 0.7 mg• -Carbon tetrachloride 2 ppm• -Chloroform 2 ppm• -Chromic acid 0.05 mg• -Formic acid 10 mg• -HCl 5 ppm• -Hydrogen Sulfide 10 ppm• -Iodine 1 ppm• -Mecury 0.05 mg
![Page 26: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/26.jpg)
Links to full OSHA lists (Table Z-1 & Z-2)of PEL-s & STEL-s
• http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=STANDARDS&p_id=9992
• http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=STANDARDS&p_id=9993
http
![Page 27: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/27.jpg)
2. Extremely flammable reagents:(low Flash /boiling point & wide LEL-UEL)
• NFPA Group 1A: -Acetaldehyde-Diethyl ether-Pentane
• NFPA Group 1B:-Acetone-Benzene-Carbon Disulfide-Cyclohexane-Ethanol-Ethyl Acetate-Heptane-Hexane-Methanol-Methyl Ethyl Ketone-Toluene
![Page 28: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/28.jpg)
TOXIC Chemical Reagents• LD50 (LC50) – experimental value, lowest dose
which kills 50% population of tested animals (rats, mice, guinea pigs…) – always indicated what animal and the route of exposure
• LDLo – lowest published lethal dose (humans too)
• Conversion factors for human doses:Rat x 0.142Mose x 0.066Guinea pigs x 0.179
![Page 29: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/29.jpg)
Classes of Toxic ChemicalsRating Oral LD50 (rat)
mg/kg bodyProbable lethal dose for Man
1. Extremely T. 1 1 grain ( drop)
2.Highly T. 1-50 4 ml ( 1 tsp.)
3.Moderately T. 50-500 30 ml ( 1 fl.oz.)
4. Slightly T. 500-5,000 600 ml
5. Practically Non-Toxic
5,000-15,000 1 L
6. Relatively harmless
>15,000
![Page 30: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/30.jpg)
Finding Toxicity Data:
• www.hazard.com • Go to: (SIRI) MSDS Index• Go to: Chemical Toxicity Data• Use chemical name or CAS#• Look for LD50/LC50…etc
![Page 31: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/31.jpg)
Our List: (LD50/oral /rat/ mg/kg body)
HgCl2 1 mgKCN 5 mgNaCN 6.4 mgHCN 10 mgHgI2 18 mgHgO 18 mgSodium Azide 27 mgMercury 29 mgHgBr2 40 mgNaAsO2 41 mg
Mercury Thiocyanate 46 mgMercuric Sulfate 57 mgHydrazine 60 mgLead Acetate 71 mgChromium trioxide 80 mgCobalt Chloride 80 mgCadmium Iodide 81 mgChromium Sulfate 85 mgCadmium Chloride 88 mgLead Nitrate 93 mg
![Page 32: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/32.jpg)
SU Chemical Hygiene Plan
- SU web site: Facilities administration/EHS/Environmental Programs
- “T” drive ( .pdf file), CHP folder- Chemistry web site/safety
![Page 33: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/33.jpg)
Other links:
• ACS Chemical safety committee web site:• http://portal.acs.org/portal/acs/corg/content?
_nfpb=true&_pageLabel=PP_TRANSITIONMAIN&node_id=2228&use_sec=false&sec_url_var=region1&__uuid=37910c5e-4cc5-4770-8c9d-bd0e411addca
• Take Safety Quiz!!! (120 question that could save your life)
![Page 34: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/34.jpg)
Lab safety elements in SU Chemistry courses:
• Initial General Chemistry trainingIn class discussion, video, in lab activity, Lab safety contract, quiz • CH 131: Labeling activity• CH132: MSDS activity• CH 133: Toxicity/LD50 activity• Organic Chemistry: first lab training, safety
teams and post lab reports
![Page 35: CHEMISTRY LABORATORY](https://reader033.fdocuments.us/reader033/viewer/2022061422/56815d8b550346895dcb977e/html5/thumbnails/35.jpg)
Laboratory ventilation
• To keep the hoods working properly the doors and windows in the labs should be kept closed all the time