    Chemical Pretreatment

    For

    RO and NF

    January 2008 

    401 Jones Road, Oceanside, CA 92058Phone: 760.901.2500 • Fax: 760.901.2664 • 1.800.CPA.Pure

     www.membranes.com

  • 8/9/2019 Chemical Pretreatment.pdf

    2/16

    Technical Application Bulletin No. 111

    Revision CPage 2 of 16

    There are a number of chemicals that can be introduced into the RO feed to enhance the

    There are a number of chemicals that can be introduced into the RO feed to enhance the

    operation of the RO system.

    •  Acids

      Caustic•  Dechlorination Chemicals

    •  Antiscalants and Dispersants

    Acids

    Acids, typically hydrochloric [HCl] or sulfuric [H2SO4], are fed to lower the feed pH.

    Sulfuric acid is used more often than hydrochloric acid, based on a lower operating cost,

    reduced fuming to the atmosphere which can corrode surrounding metal components,

    and a better membrane rejection of the sulfate ion than the chloride ion. Technical grade

    sulfuric acid, with no other additives, is suitable for use with a RO system. Sulfuric acid is

    commercially available as a 20% and 93% solution. The 93% solution is also referred to

    as 66° Baume solution. Caution is required in diluting 93% sulfuric acid, since the

    maximum heat of dilution of approximately 280°F occurs around 60%. It is critical that the

    concentrated acid is added slowly to the top of dilution water that is being agitated to

    minimize the buildup of heat and boiling of the makeup solution.

    Hydrochloric acid is preferred when there is a concern for scaling by calcium sulfate,

    barium sulfate or strontium sulfate. Sulfuric acid increases the sulfate ion level in the RO

    feed, which directly increases the potential for sulfate-based scaling. Technical grade

    hydrochloric acid (with no additives) typically is suitable for use with a RO system.

    Hydrochloric acid is typically available as a 30% to 37% solution. It is sometimes referred

    to as muriatic acid.

    The primary purpose for reducing the feed pH is to reduce the potential of calcium

    carbonate scaling in the RO concentrate as measured by using the Langlier Saturation

    Index [LSI]. LSI is a method of reporting the scaling or corrosive potential of low TDS

    brackish water based on the level of saturation of calcium carbonate [CaCO3]. LSI is

    important in RO water chemistry in determining whether a water will or will not form

    calcium carbonate scale. Water with a negative LSI is considered corrosive to metal

  • 8/9/2019 Chemical Pretreatment.pdf

    3/16

    Technical Application Bulletin No. 111

    Revision CPage 3 of 16

    piping and will not form calcium carbonate scale. Water with a positive LSI is not

    corrosive, but it will tend to form calcium carbonate scale.

    The LSI value is calculated by subtracting the calculated pH of saturation of calcium

    carbonate from the actual feed pH. Calcium carbonate solubility decreases with

    increasing temperature (as evidenced by the liming of a tea kettle), higher pH, higher

    calcium concentration, and higher alkalinity levels. The LSI value can be lowered by

    reducing pH by the injection of an acid (typically sulfuric or hydrochloric) into the RO feed

    water. A recommended target LSI in the RO concentrate is negative 0.2 (which indicates

    that the concentrate is 0.2 pH units below the point of calcium carbonate saturation). A

    negative 0.2 LSI allows for pH excursions in actual plant operation. A polymer-based

    antiscalant can also be used to inhibit the precipitation of calcium carbonate. Some

    antiscalant suppliers have reported the efficacy of their product up to a positive LSI value

    of 2.5 in the RO concentrate (though a more conservative design LSI level is +1.8).

    Caustics

    Caustics, for a few process applications, can be injected to increase the RO feed pH.

    Typically, the only caustic injected is sodium hydroxide [NaOH] based on cost, availability

    and its solubility in water.

    Most of the time the quality of the NaOH can be technical grade (and free of any

    additives). If the technical grade NaOH is not clear in color (e.g. has a blackish tint), then

    a higher grade of NaOH may be desirable such as rayon or nylon grade. NaOH is

    commercially available as 100% solid flake or as 20% or 50% solution. Caution is

    required in storing 50% caustic since it can freeze at temperatures just below 60°F

    (15.5°C), with a special concern for cold air drafts.

    Caution is required in raising the feed pH as it can decrease the solubility of CaCO 3, as

    measured by an increasing LSI, iron and manganese.

    The most common process application that uses a caustic feed involve 2nd

      pass RO

    systems. In a 2-Pass RO, the permeate from a 1st pass RO becomes the feed to the 2

    nd 

    pass. The 2nd

     pass RO “polishes” the 1st pass permeate to quality levels as good as 4

    megohm-cm. Caustic is introduced into the 2nd

     pass feed for 4 reasons.

  • 8/9/2019 Chemical Pretreatment.pdf

    4/16

    Technical Application Bulletin No. 111

    Revision CPage 4 of 16

    •  At a pH of 8.2 and higher, all carbon dioxide gas is converted into the

    bicarbonate ion. The bicarbonate ion will be rejected by the RO. Carbon

    dioxide, being a gas, would pass through the RO into the permeate stream

    unimpeded. The carbon dioxide would become an undesirable load to

    downstream polishing mixed beds.•  Certain TOC constituents are better rejected at a higher pH.

    •  Silica rejection and solubility are higher at higher pH levels (particularly above a

    pH of 9).

    •  Boron rejection is higher at higher pH levels (particularly above a pH of 9).

    One special process application, frequently referred to as the HEROTM

      process,

    institutes a caustic feed to raise feed pH to 9 or 10. The RO operates in a 1st pass mode

    and uses a brackish quality feed water. Brackish waters can contain potential foulants

    that become more of an issue at higher pH (e.g. hardness, alkalinity, iron, manganese,

    etc.). Pretreatment frequently uses a weak acid cation exchange system and a degasifier

    to remove these potential foulants.

    Dechlorination Chemicals

    At no time should there be a Free Chlorine residual in the feed water. Even very low

    levels of chlorine in the feed stream will result in irreparable oxidation damage of themembrane. Therefore, operators should ensure that oxidant does not enter the RO

    system. The two most common pretreatment methods for reducing chlorine levels are by

    absorption onto granular activated carbon filter media or by the use of a chemical

    reducing agent such as sodium bisulfite.

    Pressurized carbon filters are typically used on small systems (50 gpm to 100 gpm or

    less) due to capital cost considerations. It is recommended that a premium grade of

    carbon is used that has been acid-washed for the removal of heavy metals and hardness

    and has very low levels of carbon fines that can foul the RO. Anytime new carbon media

    is installed, the carbon filter must be thoroughly rinsed until all carbon fines are absent

    from the effluent (this can take a few hours to days). One cannot rely on a 5-micron

    cartridge filter to protect the RO element from fouling due to carbon fines. The

    advantages of a carbon filter are their ability to remove organics from the feedwater that

    could foul the RO and that they are more reliable in treating all the feed water than a

    chemical feed system. The disadvantage is that carbon filters are notorious for breeding

  • 8/9/2019 Chemical Pretreatment.pdf

    5/16

    Technical Application Bulletin No. 111

    Revision CPage 5 of 16

    bacteria that can result in a biological fouling of the RO. Carbon filters have been known

    to see a doubling of viable bacteria counts in 24 hours, with capital intensive and operator

    intensive periodic steam sanitization the only answer for controlling microbial populations.

    Steam sanitization for critical applications (like USP Water production for the

    pharmaceutical industry) can be as frequent as 1 to 7 days.

    Sodium Bisulfite [SBS] is the typical chlorine reducing agent of choice for larger RO

    systems. Note:  SBS should not be cobalt catalyzed. A SBS solution is made by

    dissolving solid sodium metabisulfite into water and has a pH of 4.6 at 1.0% (by weight)

    solution strength. A 10% (by weight) SBS solution will require the addition of 0.51 pounds

    of solid sodium metabisulfite into one gallon of water. The sodium metabisulfite is

    commercially available at 97.5% to 99% purity and can be stored safely up to six months

    in a dry storage area. The SBS solution is not stable to air and reacts with oxygen as well

    as chlorine, therefore it is recommended that batches less than 2% by weight be used

    within 3 to 7 days and batch solutions less than 10 % be used within 7 to 14 days.

    Theoretically, 1.47 ppm of SBS (or 0.70 ppm of sodium metabisulfite) will

    stoichiometrically neutralize 1.0 ppm of chlorine. Designers have been known to use a

    dosing rate of 1.8 ppm to 3.0 ppm of SBS per 1.0 ppm chlorine so as to include an

    industrial safety factor for brackish water RO systems. SBS needs to be added far

    enough upstream of the RO elements to insure at least 20 seconds of reaction time.

    Proper in-line mixing is required which preferably includes a static mixer.

    Na2S2O5 (sodium metabisulfite) + H2O →  2 NaHSO3 (sodium bisulfite)

    NaHSO3 + HOCl →  NaHSO4 (sodium bisulfate) + HCl (hydrochloric acid)

    NaHSO3 + Cl2 + H2O →  NaHSO4 + 2 HCl 

    The advantages of SBS dechlorination are that it is less capital intensive than carbon

    filters for large systems, the reaction by-products are readily removed by the RO, and

    residual SBS is readily removed by the RO.

    The disadvantages of SBS can be the need to handle and mix a small volume of chemicaland an increased risk in chlorine making it to the membranes if sufficient monitoring and

    controls are not designed into the dechlorination system. In a few cases where Sulfur

    Reducing Bacteria [SBRs] are present in the feed supply, the bisulfite functions as a

    nutrient and enhances their growth. SBRs are usually found in anaerobic (low oxygen

    content) shallow wells in regions such as Florida. Frequently hydrogen sulfide (H2S) is

    also present as a by-product of the SBR metabolic process.

  • 8/9/2019 Chemical Pretreatment.pdf

    6/16

    Technical Application Bulletin No. 111

    Revision CPage 6 of 16

    Monitoring for dechlorination can be performed by the use of an Available Free Chlorine

    monitor, monitoring for a residual bisulfite concentration, or by an ORP meter.

    Hydranautics recommends that the feed to the RO/NF system is equipped with a ORP

    (Oxidation-Reduction Potential) meter. The feedwater can then be continuously

    monitored for the presence of oxidant. Except in wastewater applications where

    chloramines are used, the ORP meter reading should always be below 300 mV. If it

    exceeds 300 mV, the plant operator should receive a warning that a dangerous level of

    oxidant is getting to the membrane and should take action, such as adding or increasing

    the dose of SBS, to reduce the oxidant concentration. If the ORP value reaches 350 mV,

    the plant should be shut down until the oxidant concentration can be reduced to a safe

    value (ORP < 300 mV).

    CPA membranes have an estimated chlorine tolerance of 1,000 ppm-hours to 2,000

    ppm-hours before a doubling in salt passage occurs. The 1,000 ppm-hours level

    correlates to a chlorine level in the RO feed of 0.038 ppm for an operating period of 3

    years. RO designers are cautioned that it has been observed that this chlorine tolerance

    can be dramatically reduced by the catalytic effects of increasing temperature (90° F or

    higher), increasing pH (7 or higher), or by the presence of transition metals on the

    membrane surface (e.g. iron, manganese, zinc, copper, aluminum, etc.).

    CPA membranes have an estimated chloramine tolerance of 50,000 ppm-hours before a

    noticeable increase in salt passage occurs. The 50,000 ppm-hours level correlates to achloramine level in the RO feed of 1.9 ppm for an operating period of 3 years. RO

    designers are cautioned that it has been observed that chloramine tolerance can vary

    due to the catalytic effects of high temperature, low pH, or presence of transition metals.

    One application at a tertiary waste water plant in California indicated a reduction of

    system salt rejection from 98% to 96% in 2 to 3 years with chloramines at 6 to 8 ppm. The

    designer must also be aware that dechlorination after chloramination may be required.

    Chloramines are produced by mixing chlorine and ammonia. Residual free chlorine,

    which can deteriorate membranes much more quickly than chloramines, can be present if

    insufficient ammonia is used. Therefore, it is vital that there is always an excess ofammonia, and the system should be monitored to ensure this. For more details on

    chloramines, please contact Hydranautics Technical Support Department.

  • 8/9/2019 Chemical Pretreatment.pdf

    7/16

    Technical Application Bulletin No. 111

    Revision CPage 7 of 16

    Antiscalants and Dispersants

    There are a large number of chemical suppliers who supply a variety of proprietary

    antiscalants and dispersants to improve the operation of RO and NF systems.

    Antiscalants are a family of chemicals designed to inhibit the formation and precipitation

    of crystallized mineral salts that form scale. Most antiscalants are proprietary organic

    man-made polymers (e.g. polyacrylic acids, carboxylic acids, polymaleic acids,

    organo-phosphates, polyphosphates, phosphonates, anionic polymers, etc.). Molecular

    weight of these polymers can range from 2,000 Dalton to 10,000 Dalton.

    Antiscalant technology for RO systems initially was derived from chemistries used in

    cooling water and boiler water applications. It should be duly noted that the large number

    of different antiscalant chemistries that have evolved have produced a wide variety of

    results and efficacy depending on the application and organic polymer used.

    Caution should be used in the use of antiscalants made of polyacrylic acid. They are

    susceptible to the formation of a foulant that settles on the membrane surface if there are

    high levels of iron. This foulant will increase feed pressure requirements, but typically can

    be cleaned using a low pH cleaning.

    Caution should also be used in the use of antiscalants that are anionic in nature (e.g.

    polyacrylic acids) when a cationic-based coagulant or filtering aid is used in the

    pretreatment. A very viscous, sticky foulant can be produced that will increase feed

    pressure requirements, and it can be very difficult to clean off.

    An antiscalant that was popular in the early days of RO was sodium hexametaphosphate

    (SHMP), but its use has been greatly reduced with the advent of proprietary antiscalants.

    SHMP has a number of limitations. Batches of diluted SHMP has to made every 2 to 3

    days due to hydrolysis by exposure to air, which would dilute its efficacy and create apotential calcium phosphate scaling risk. SHMP has a reduced protection to calcium

    carbonate scaling with a maximum LSI rating in the concentrate of +1.0.

    Antiscalants retard the growth of crystalline salt structures in the RO feed and

    concentrate streams, thereby allowing a concentration of sparingly soluble salts in

    excess of the normal solubility limits. Antiscalants can be used to replace, or can be used

  • 8/9/2019 Chemical Pretreatment.pdf

    8/16

  • 8/9/2019 Chemical Pretreatment.pdf

    9/16

    Technical Application Bulletin No. 111

    Revision CPage 9 of 16

    Predicting the maximum levels of metals (e.g. iron, manganese, aluminum) can also be

    difficult. The soluble forms of the metal ions allow for higher levels of saturation. The

    insoluble forms tend to act more like particles and colloids.

    Optimal dosing and allowable maximum saturation levels of scalants and foulants for

    antiscalants/dispersants are best determined by the chemical supplier who utilizes a

    proprietary software package. Hydranautics utilizes conservative estimates in its

    IMSDesign software for alarm purposes in estimating the allowable level of

    super-saturation of sparingly soluble salts.

    Maintaining proper dosing levels of an antiscalant/dispersant is important. Under-dosing

    can cause scaling or fouling. Over-dosing can cause a deposition of the

    antiscalant/dispersant onto the membrane, creating a fouling problem.

    It is important that the antiscalant/dispersant be thoroughly flushed from the RO elements

    at shutdown, as it can settle onto the membrane and cause a fouling problem. The

    injection of antiscalant/dispersant should cease during low pressure flushes when the RO

    feed water is the source of flush water.

    The design of the antiscalant/dispersant injection system into the RO feed stream needs

    to make sure that it is properly mixed before it enters the RO elements. The use of a

    static mixer is the most effective mixing method, but adds cost to a system. Most systemshave the injection point just before the RO feed cartridge filter(s) and rely on the cartridge

    filter residence time and RO feed pump agitation to affect the mixing.

    It is recommended that if there is an acid pH adjustment of the RO feed water, the acid

    should be injected upstream and thoroughly mixed before it reaches the

    antiscalant/dispersant injection point. Concentrated pockets of low pH acid may destroy

    the efficacy of the antiscalant/dispersant.

    The chemical metering pump used for the injection of antiscalant/dispersant should beadjusted to maximize the frequency of injection. A suggested minimum stroking

    frequency is once every 5 seconds. Typical dosing rates of antiscalants/dispersants are

    2 to 5 ppm. To achieve a reasonable stroking frequency of the metering pump, a dilution

    of the antiscalant/dispersant may be required.

    Antiscalants/dispersants are supplied as either a concentrated liquid or in a powder form.

  • 8/9/2019 Chemical Pretreatment.pdf

    10/16

    Technical Application Bulletin No. 111

    Revision CPage 10 of 16

    Dilution water should be hardness-free and preferably be of RO permeate quality.

    Diluted antiscalant/dispersants can become biologically fouled in the day tank depending

    on temperatures and how much it has been diluted. A suggested residence time for a

    diluted solution is 7-10 days. Normally, undiluted antiscalant/dispersant solutions do not

    suffer from biological fouling.

    The table below reflects the upper operating limits of saturation reported by chemical

    suppliers and the typically conservative alarm points used in the Hydranautics RO design

    program. These values are based on the concentrate stream, with normal saturation limit

    of 100% without use of an antiscalant/dispersant. Hydranautics will always recommend

    that you contact the chemical supplier to confirm the efficacy of a product.

    Scalant or Foulant Maximum Reported Hydranautics Alarm

    LSI (calcium carbonate) + 2.9 + 1.8

    Calcium Sulfate 400% 230%

    Strontium Sulfate 1,200% 800%

    Barium Sulfate 8,000% 6,000%

    Calcium Fluoride 12,000% Not alarmed

    Silica 300 ppm or more 100%

    Iron 5 ppm not alarmed

    Aluminum 4 ppm not alarmed

    Another major issue in selecting an antiscalant/dispersant is the assurance that it is

    compatible with the RO membrane being used. There are incompatible chemicals that

    can irreversibly foul or damage a RO membrane. Hydranautics relies on the supplier of

    the chemical to have performed all RO membrane compatibility and process efficacy

    tests.

    Some recommended questions to ask chemical suppliers of antiscalants and dispersantsare:

    •  Is it compatible with the RO membrane type in question?

    •  Is there an installation list of end-users with over 1000 hours of successful

    operation?

    •  Does it react adversely with any other constituents in the RO feed water (e.g.

    iron, heavy metals, cationic polyelectrolytes, etc.)?

  • 8/9/2019 Chemical Pretreatment.pdf

    11/16

    Technical Application Bulletin No. 111

    Revision CPage 11 of 16

    •  What are the recommended dosing rates and maximum dosing rates?

    •  What are the projected limits of solubility for individual scaling and fouling

    components?

    •  Are there any special discharge concerns?

    •  Is it suitable for potable water applications (if required)?•  Does the supplier offer other RO chemical feeds like antiscalant-compatible

    coagulants, biocides and cleaning chemicals?

    •  Does the supplier offer off-site technical support services like membrane

    autopsies or cleaning of elements?

    Glossary

    Alkalinity:  Alkalinity is comprised primarily of carbon dioxide, bicarbonate, carbonate

    and hydroxides. Naturally occurring alkalinity is the earth’s natural buffering system in

    that small doses of strong acids (e.g. acid rain) react with alkalinity and result in relatively

    small changes in pH. Carbon dioxide and bicarbonate are in a balance between the pH

    range of 4.4 and 8.2. At a pH of 4.4 or lower, all alkalinity is in the form of carbon dioxide.

    At a pH of 8.2, there is no carbon dioxide and all alkalinity is bicarbonate. Bicarbonate

    and carbonate are in a balance between the pH range of 8.2 and 9.6. At a pH of 9.6,

    there is no carbon dioxide or bicarbonate and all alkalinity is carbonate. As the pH

    increases above 9.6, hydroxyl alkalinity due to the presence of the hydroxide ion starts to

    occur. Most naturally occurring water sources have a pH between 6 and 8.4, so the

    presence of hydroxides is the result of man-made activity. Alkalinity, especially by boiler

    water chemists, can be reported as M-Alkalinity and P-Alkalinity. M-Alkalinity measures

    the Total Alkalinity in a water in terms of “ppm as calcium carbonate” based on an acid

    titration to a pH of 4.2 using a Methyl orange indicator endpoint. P-Alkalinity measures

    the amount of bicarbonate, carbonate and hydroxyl alkalinity based on an acid titration to

    a pH of 8.2 using a Phenolphthalein pink indicator endpoint.

    Barium (Ba):  A divalent cation. The solubility of barium sulfate (BaSO4) is low and can

    cause a RO scaling problem in the back-end of a RO. Barium sulfate solubility is lower

    with increasing sulfate levels and decreasing temperatures. Typically, barium can be

    found in some well waters, with typical concentrations less than 0.05 ppm to 0.2 ppm. It

    is important that barium be measured with instruments capable of 0.01 ppm (10 ppb)

    minimum detection levels. With saturation at 100%, super-saturation up to 6000% is

    typical with an antiscalant.

  • 8/9/2019 Chemical Pretreatment.pdf

    12/16

    Technical Application Bulletin No. 111

    Revision CPage 12 of 16

    Bicarbonate (HCO3):  A monovalent anion. The solubility of calcium bicarbonate is low

    and can cause a RO scaling problem in the back-end of a RO. Calcium bicarbonate

    solubility is measured using LSI (Langlier Saturation Index) for brackish waters or the

    Stiff-Davis Index for seawaters and is lower with increasing temperature and increasing

    pH. Bicarbonate is one component of alkalinity and its concentration is in a balance with

    carbon dioxide between the pH range of 4.4 and 8.2 and in a balance with carbonate

    between the pH range of 8.2 and 9.6.

    Calcium (Ca):  A divalent cation. Calcium, along with magnesium, is a major component

    of hardness in brackish water. The solubility of calcium sulfate (CaSO4)(gypsum) is

    typically limited to 230% with the use of an antiscalant. The solubility of calcium

    carbonate is typically limited to a LSI (Langlier Saturation Index) value of positive 1.8 to

    2.5.

    Carbon Dioxide (CO2):  Carbon dioxide is a gas that when dissolved in water reacts with

    the water to form weak carbonic acid (H2CO3). If a pure water was completely saturated

    with carbon dioxide, its concentration would be about 1600 ppm and the pH would be

    about 4.0. A typical source for carbon dioxide in natural waters is the result of a balance

    with bicarbonate alkalinity based on the pH of the water. The concentration of carbon

    dioxide in water is typically indirectly determined by graphical comparison to the

    bicarbonate concentration and pH. Carbon dioxide and the bicarbonate ion are in a

    balance between the pH range of 4.4 and 8.2. The alkalinity is all carbon dioxide at pH

    4.4 and is all bicarbonate at pH 8.4. The RO design program calculates the carbon

    dioxide level based on the bicarbonate level and pH of the water. Carbon dioxide, being

    a gas, is not rejected or concentrated by a RO membrane, therefore its concentration will

    be the same in the feed, permeate and concentrate. Acidifying the RO feed water will

    lower pH by converting bicarbonate to carbon dioxide.

    Carbonate (CO3):  A divalent anion. The solubility of calcium carbonate is low and can

    cause a RO scaling problem in the back-end of a RO. Calcium carbonate solubility is

    measured using LSI (Langlier Saturation Index) for brackish waters or SDSI (Stiff-DavisIndex) for seawaters and is lower with increasing temperature and increasing pH.

    Carbonate is one component of alkalinity and its concentration is in a balance with

    bicarbonate between the pH range of 8.2 and 9.6. At a pH of 9.6 and higher, there is no

    carbon dioxide or bicarbonate, with all alkalinity being in the carbonate form.

    Ionic Strength:  The solubility of sparingly soluble salts increases with increasing feed

  • 8/9/2019 Chemical Pretreatment.pdf

    13/16

    Technical Application Bulletin No. 111

    Revision CPage 13 of 16

    TDS. To account for this effect in calculating the solubility of a salt (e.g. calcium sulfate,

    barium sulfate, strontium sulfate or SDSI), the Ionic Strength of a water is calculated. The

    Ionic Strength of each ion is derived by taking the ppm concentration of each ion (as

    calcium carbonate) and multiplying each monovalent ion by 1 x 10-5 and each divalent

    ion by 2 x 10-5. Summing the Ionic Strength of each ion then derives the total Ionic

    Strength of the water.

    Iron (Fe):  Iron is a water contaminant that takes two major forms. The water-soluble

    form is known as the ferrous state and has a + 2 valence state. In non-aerated well

    waters ferrous iron behaves much like calcium or magnesium hardness in that it can be

    removed by softeners or its precipitation in the back end of the RO system can be

    controlled by the use of a dispersant chemical in an RO feed water. The water-insoluble

    form is known as the ferric state and has a + 3 valence state. Typically, RO

    manufacturers will recommend that combined iron levels be less than 0.05 ppm in the RO

    feed. If all iron is in the soluble ferrous form, iron levels up to 0.5 ppm in the feed can be

    tolerated if the pH is less than 7.0 (though an iron dispersant is recommended). The

    introduction of air into water with soluble ferrous iron will result in the oxidation to

    insoluble ferric iron. Soluble iron can be found in deep wells, but can be converted into

    the more troublesome insoluble iron by the introduction of air by being placed in tanks or

    by leaky pump seals. Soluble iron can be treated with dispersants or can be removed by

    iron filters, softeners or lime softening. Insoluble ferric iron oxides or ferric hydroxides,

    being colloidal in nature, will foul the front end of the RO system. Sources of insoluble

    iron are aerated well waters, surface sources, and iron scale from unlined pipe and tanks.

    Insoluble iron can be removed by iron filters, lime softening, softeners (with limits),ultrafiltration (with limits) and multimedia filtration with polyelectrolyte feed (with limits).

    Precautions are required with the use of potassium permanganate in manganese

    greensand iron filters in that potassium permanganate is an oxidant that could damage

    any polyamide membrane. Precautions are also required with a cationic polyelectrolyte

    in that they can irreversibly foul a negatively charged polyamide membrane. Corrosion

    proof vessels and piping (e.g. FRP, PVC or stainless steels) are recommended for all RO

    systems, RO pretreatment, and distribution piping coming to the RO system. Iron as

    foulant will quickly increase RO feed pressure requirements and increase permeate TDS.

    In some cases, the presence of iron can create a bio-fouling problem by being the energysource for iron-reducing bacteria. Iron-reducing bacteria can cause the formation of a

    slimy biofilm that can plug the RO feed path.

    LSI (Langlier Saturation Index):  LSI is a method of reporting the scaling or corrosive

    potential of low TDS brackish water based on the level of saturation of calcium carbonate.

    LSI is important in RO water chemistry in determining whether a water will or will not form

  • 8/9/2019 Chemical Pretreatment.pdf

    14/16

    Technical Application Bulletin No. 111

    Revision CPage 14 of 16

    calcium carbonate scale. Water with a negative LSI is considered corrosive to metal

    piping and will not form calcium carbonate scale. Water with a positive LSI is not

    corrosive, but it will tend to form calcium carbonate scale. LSI is important to RO chemists

    as a measurement of the scaling potential for calcium carbonate. The LSI value is

    calculated by subtracting the calculated pH of saturation of calcium carbonate from the

    actual feed pH. Calcium carbonate solubility decreases with increasing temperature (as

    evidenced by the liming of a teakettle), higher pH, higher calcium concentration, and

    higher alkalinity levels. The LSI value can be lowered by reducing pH by the injection of

    an acid (typically sulfuric or hydrochloric) into the RO feed water. A recommended target

    LSI in the RO concentrate is negative 0.2 (which indicates that the concentrate is 0.2 pH

    units below the point of calcium carbonate saturation). A negative 0.2 LSI allows for pH

    excursions in actual plant operation. A polymer-based antiscalant can also be used to

    inhibit the precipitation of calcium carbonate. Some antiscalant suppliers have claimed

    the efficacy of their product up to a positive LSI value of 2.5 in the RO concentrate

    (though a more conservative design LSI level is +1.8). Sodium hexametaphosphate, an

    inorganic antiscalant, was used in the early days of RO but the maximum concentrate LSI

    was + 0.5 and it had to be made in short-lived batches as the air easily oxidized it.

    Magnesium (Mg):  A divalent cation. Magnesium can account for about a third of the

    hardness in a brackish water, but can have a concentration five times higher than calcium

    in sea water. The solubility of magnesium salts is high and typically does not cause a

    scaling problem in RO systems.

    Manganese (Mn):  Manganese is a water contaminant present in both well and surfacewaters, with levels up to 3 ppm. Manganese, like iron, can be found in organic complexes

    in surface waters. In oxygen-free water, it is soluble. In the oxidized state, it is insoluble

    and usually in the form of black manganese dioxide (MnO2) precipitate. An alert level for

    potential manganese fouling in a RO aerated RO feed waters is 0.05 ppm. Drinking water

    regulations limit manganese to 0.05 ppm due to its ability to cause black stains.

    Dispersants used to control iron fouling can be used to help control manganese fouling.

    pH:  The pH of the feed water measures the acidity or basicity. A pH of 7.0 is considered

    neutral. A pH between 0.0 and 7.0 is acidic. A pH between 7.0 and 14.0 is basic. To theanalytical chemist, pH is a method of expressing hydrogen ion concentration in terms of

    the power of 10 with the pH value being the negative logarithm of the hydrogen ion

    concentration. To the water chemist, pH is important in defining the alkalinity equilibrium

    levels of carbon dioxide, bicarbonate, carbonate and hydroxide ions. The concentrate pH

    is typically higher than the feed due to the higher concentration of bicarbonate/carbonate

    ions relative to the concentration of carbon dioxide. The RODESIGN program allows the

  • 8/9/2019 Chemical Pretreatment.pdf

    15/16

    Technical Application Bulletin No. 111

    Revision CPage 15 of 16

    user to adjust the pH of the feed water using hydrochloric and sulfuric acid. Lowering the

    feed pH with acid results in a lower LSI (Langlier Saturation Index) value, which reduces

    the scaling potential for calcium carbonate. Feed and concentrate (reject) pH can also

    affect the solubility and fouling potential of silica, aluminum, organics and oil. Variations

    in feed pH can also affect the rejection of ions. For example, fluoride, boron and silica

    rejection are lower when the pH becomes more acidic.

    SDSI (Stiff Davis Saturation Index):  SDSI, in similar fashion as LSI, is a method of

    reporting the scaling or corrosion potential of high TDS seawater based on the level of

    saturation of calcium carbonate. The primary difference between SDSI for high TDS

    seawater and LSI for low TDS brackish water is the effect that increasing ionic strength

    has on increasing solubility. The solubility of sparingly soluble salts increase with higher

    TDS and ionic strength, based on the theory that a denser ion population interferes in the

    formation and/or precipitation of the sparingly soluble salt.

    Silica (SiO2):  Silica (silicon dioxide), in some cases, is an anion. The chemistry of silica

    is a complex and somewhat unpredictable subject. In similar fashion as TOC reports the

    total concentration of organics (as carbon) without detailing what the organic compounds

    are, silica reports the total concentration of silicon (as silica) without detailing what the

    silicon compounds are. The “Total Silica” content of water is composed of “Reactive

    Silica” and “Unreactive Silica”. Reactive silica (e.g. silicates SiO4) is dissolved silica that

    is slightly ionized and has not been polymerized into a long chain. Reactive silica is the

    form that RO and ion exchange chemists hope for. Reactive silica is the form of silica to

    be used in RO projection programs. Reactive silica, though it has anionic characteristics,is not counted as an anion in terms of balancing a water analysis but it is counted as a

    part of total TDS. Unreactive silica is polymerized or colloidal silica, acting more like a

    solid than a dissolved ion. Silica, in the colloidal form, can be removed by a RO but it can

    cause colloidal fouling of the front-end of a RO. Colloidal silica, with sizes as small as

    0.008 micron can be measured empirically by the SDI (Silt Density Index) test, but only

    that portion that is larger than 0.45 micron or larger. Particulate silica compounds (e.g.

    clays, silts and sand) are usually 1 micron or larger and can be measured using the SDI

    test. Polymerized silica, which uses silicon dioxide as the building block, exists in nature

    (e.g. quartzes and agates). Silica, in the polymerized form, also results from exceedingthe reactive silica saturation level. The solubility of reactive silica is typically limited to

    200-300% with the use of a silica dispersant. Reactive silica solubility increases with

    increasing temperature, increases at a pH less than 7.0 or more than 7.8, and decreases

    in the presence of iron which acts as a catalyst in the polymerization of silica. Silica

    rejection is pH sensitive, with increasing rejection at a more basic pH as the reactive silica

    exists more in the salt form than in the acidic form.

  • 8/9/2019 Chemical Pretreatment.pdf

    16/16

    Technical Application Bulletin No. 111

    Strontium (Sr):  A divalent cation. The solubility of strontium sulfate is low and can

    cause a RO scaling problem in the back-end of a RO. Strontium sulfate solubility is lower

    with increasing sulfate levels and decreasing temperatures. Typically, strontium can befound in some well waters where lead ores are also present, with typical concentrations

    less than 15 ppm. With saturation at 100%, super-saturation up to 800% is typical with an

    antiscalant.

    Sulfate (SO4):  A divalent anion. The solubility of calcium, barium and strontium sulfate

    is low and can cause a RO scaling problem at the concentrate end of a RO. The solubility

    of these sparingly soluble salts is lower with decreasing temperature. The recommended

    upper limit for sulfate in potable water is 250 ppm based on taste issues.