Chemical Anchors
-
Upload
werner-schulz -
Category
Documents
-
view
221 -
download
0
Transcript of Chemical Anchors
-
7/27/2019 Chemical Anchors
1/2F0071
1. Applicationsl Can be used for medium to heavy loadsl With European Technical Approval, the anchor can be used in
reinforced or non-reinforced standard concrete with a strengthclass of at least C20/25 and at most C50/60 in accordancewith EN 206:2000-12
l Anchorage with European Technical Approval in uncrackedconcrete (concrete pressure zone)
l The anchor may be used for anchorage with primarily staticloads (e.g. own weight, installations, support materials) or
quasi-static loadsl Installation in dry or wet concretel The temperature in the mortar area may not exceed +50 C
and briefly +80Cl For use in concrete < C20/25 and pressure-resistant natural
stone (without approval)l W-VD/S (galvanized steel) can be used in dry interior rooms
l Suitable for fastening metal constructions, metal profiles,brackets, foot plates, supports, wood structures, beams etc.
2. Advantagesl Heavy loads, small axial and edge distancesl Hardened composite mortar largely seals off the drill holel Attachment with low expansion pressure allows small edge
and axial clearances
3. Propertiesl Anchoring through bond between mortar, anchor bar and
anchoring base. Galvanized anchor bar in the sizes M8, M10,M12, M16, M20 and M24
l Galvanized steel: European Technical Approval ETA-06/0074l Dimensioned in accordance with the Guideline for European
Technical Approval (ETAG) of Metal Anchors for Use in Con-crete, Annex C, dimensioning method A
l Fire resistance: F30, F60, F90, F120: One-sided fire stressaccording to DIN EN 1363-1:1999-10
Test reportsApprovals
Setting instructions
MWF-04/08-04276-
21.1W-VD/SShear-AnchorCartridgeSystemIndividual attachment:Uncracked concrete
Galvanized steel
W-VD/A4 Shear-anchor cartridgesystem see
W-VD/HCR Shear-anchor cartridgesystem see
Evidence of performance
Drill hole 1x blow-out,1x brush-out,1x blow-out,1x brush-out
Resin must flow likehoney when cartridgeis hand-warm
Push in cartridge Set threadedrod rotating/impacting
Visual checkof mortar fillingquantity
Observe thehardening time
Mount component,apply torque
EuropeanTechnical
ApprovalOption 8
for uncracked concrete
FireResistance
Drill hole cleaning
Cleaning the drill hole: 1x blow-out, 1x brush-out,1x blow-out, 1x brush-out
Installation instructions
Set anchor bar rotating and + impacting with hammerdrill or percussion drill.
21.2
21.2
-
7/27/2019 Chemical Anchors
2/2F0072
1) The part safety coefficients of the resistances and a part safety coefficient of the effects of F= 1.4 have been takeninto account. For the combination of tensile and transverse loads, for edge influence anddowel groups, pleaserefer to the Directive for European Technical Approval (ETAG) Appendix C.
2) Maximum long-term temperature.3) Maximum short-term temperature.4) Cleaning brush without M6 connecting thread.
Performance data
Anchor diameter M8 M10 M12 M16 M20 M24
Pressure zone(uncracked concrete C20/25 Nperm [kN] = C20/25 7.9 11.9 15.9 19.8 29.8 35.7
M8: s
3 hef, c
1.5 hef 50C2)
/80C3)
M10-M24: s 2 hef, c 1hef)
Pressure zone(uncracked concrete C20/25, Vperm [kN] = C20/25 5.1 8.0 12.0 22.3 34.9 50.3c 10 hef)
Permissible bending torque Mperm [Nm] 10.9 21.1 37.1 94.9 185.7 320.6
Fire resistance time F30 [kN] 2.3 3.64 5.26 9.79 15.28 22.01
F60 [kN] 1.29 2.04 3.07 5.72 8.93 12.86
F90 [kN] 0.79 1.3 2.0 3.68 5.75 8.28
F120 [kN] 0.53 1.0 1.5 2.67 4.16 6.0
Perm
.centered
ten
sileload1)
ofas
ingleanc
hor
w/oedgeinfluence
Perm.
transv.
load1)
ofasingleanc
hor
w/oedgeinfluence
MWF-04/08-04277-
Characteristic values
Minimum axial spacing smin [mm] 40 45 55 65 85 105
Axial spacing scr,N [mm] 240 180 220 250 340 420Minimum edge spacing cmin [mm] 40 45 55 65 85 105
Edge spacing ccr,N [mm] 120 90 110 125 170 210
Minimum component thickness hmin [mm] 110 120 140 160 220 260
Effective anchoring depth hef [mm] 80 90 110 125 170 210
Nom. drill dia. d0 [mm] 10 12 14 18 25 28
Drill cutting dia. dcut [mm] 10.5 12.5 14.5 18.5 25.5 28.5
Drilled hole depth h0 [mm] 80 90 110 125 170 210
Through-hole incomponent to be connected
df [mm] 9 12 14 18 22 26
Torque during anchoring Tinst = [Nm] 10 20 40 80 120 180
Cleaning brush dia. D [mm] 10.8 13 15 19 27 29
Drill hole cleaning M8 M 24: 1x blow-out, 1x brush-out, 1x blow-out, 1x brush-out
Cleaning brush (steel) Art. No. P. Qty. =1 0905 499 001 0905 499 002 0905 499 003 0905 499 004 0905 499 006 0905 499 0084)
Machine mounting Art. No. P. Qty. =1 Hexagon:Art. No. 0905 499 101 SDS plus:Art. No. 0905 499 102
Extension Art. No. P. Qty. =1 0905 499 111
Brush template Art. No. P. Qty. =1 0905 499 099
Blow-out pump Art. No. P. Qty. =1 Blow-out pump:Art. No. 0903 990 001
Anchor dimensionsAnchor diameter M8 M10 M12 M 16 M20 M24
Total length l [mm]
max. mounting height tfix[mm]
DesignationAnchor bar
W-VD-A/S Anchor Bar,galvanized steel
Art. No.
Packing unit P. Qty.
DesignationShear-anchor mortar cartridge
W-VD shear-anchor mortarcartridge
Art. No.
Packing unit P. Qty. [pieces]
110
150
115
130
165
190
135
160
210
250
300
165
190
230
250
300
220
260
300
260
300
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10 5 5
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0 5 5
59151
081
10
59151
081
50
59151
101
15
59151
101
30
59151
101
65
59151
101
90
59151
121
35
59151
121
60
59151
122
10
59151
122
50
59151
123
00
59151
161
65
59151
161
90
59151
162
30
59151
162
50
59151
163
00
59151
202
20
59151
202
60
59151
203
00
59151
242
60
59151
243
00
59150
080
80
59150
080
80
59150
100
80
59150
100
80
59150
100
80
59150
100
80
59150
120
95
59150
120
95
59150
120
95
59150
120
95
59150
120
95
59150
160
95
59150
160
95
59150
160
95
59150
160
95
59150
160
95
59150
201
75
59150
201
75
59150
201
75
59150
242
10
59150
242
10
W-VDM8
W-VDM8
W-VDM10
W-VDM10
W-VDM10
W-VDM10
W-VDM12
W-VDM12
W-VDM12
W-VDM12
W-VDM12
W-VDM16
W-VDM16
W-VDM16
W-VDM16
W-VDM16
W-VDM20
W-VDM20
W-VDM20
W-VDM24
W-VDM24
Fire resistance duration
20
60
15
30
65
90
10
35
85
125
175
20
45
85
105
155
20
60
100
15
55
W-VD-A/SM8-20/110
W-VD-A/SM8-60/150
W-VD-A/SM10-15/115
W-VD-A/SM10-30/130
W-VD-A/SM10-65/165
W-VD-A/SM10-90/190
W-VD-A/SM12-10/135
W-VD-A/SM12-35/160
W-VD-A/SM12-85/210
W-VD-A/SM12-125/250
W-VD-A/SM12-175/300
W-VD-A/SM16-20/165
W-VD-A/SM16-45/190
W-VD-A/SM16-85/230
W-VD-A/SM16-105/250
W-VD-A/SM16-155/300
W-VD-A/SM20-20/220
W-VD-A/SM20-60/260
W-VD-A/SM20-100/300
W-VD-A/SM24-15/260
W-VD-A/SM24-55/300
W-VD/SShear-Anchor Cartridge System 21.1