Chemical Anchors

download Chemical Anchors

of 2

Transcript of Chemical Anchors

  • 7/27/2019 Chemical Anchors

    1/2F0071

    1. Applicationsl Can be used for medium to heavy loadsl With European Technical Approval, the anchor can be used in

    reinforced or non-reinforced standard concrete with a strengthclass of at least C20/25 and at most C50/60 in accordancewith EN 206:2000-12

    l Anchorage with European Technical Approval in uncrackedconcrete (concrete pressure zone)

    l The anchor may be used for anchorage with primarily staticloads (e.g. own weight, installations, support materials) or

    quasi-static loadsl Installation in dry or wet concretel The temperature in the mortar area may not exceed +50 C

    and briefly +80Cl For use in concrete < C20/25 and pressure-resistant natural

    stone (without approval)l W-VD/S (galvanized steel) can be used in dry interior rooms

    l Suitable for fastening metal constructions, metal profiles,brackets, foot plates, supports, wood structures, beams etc.

    2. Advantagesl Heavy loads, small axial and edge distancesl Hardened composite mortar largely seals off the drill holel Attachment with low expansion pressure allows small edge

    and axial clearances

    3. Propertiesl Anchoring through bond between mortar, anchor bar and

    anchoring base. Galvanized anchor bar in the sizes M8, M10,M12, M16, M20 and M24

    l Galvanized steel: European Technical Approval ETA-06/0074l Dimensioned in accordance with the Guideline for European

    Technical Approval (ETAG) of Metal Anchors for Use in Con-crete, Annex C, dimensioning method A

    l Fire resistance: F30, F60, F90, F120: One-sided fire stressaccording to DIN EN 1363-1:1999-10

    Test reportsApprovals

    Setting instructions

    MWF-04/08-04276-

    21.1W-VD/SShear-AnchorCartridgeSystemIndividual attachment:Uncracked concrete

    Galvanized steel

    W-VD/A4 Shear-anchor cartridgesystem see

    W-VD/HCR Shear-anchor cartridgesystem see

    Evidence of performance

    Drill hole 1x blow-out,1x brush-out,1x blow-out,1x brush-out

    Resin must flow likehoney when cartridgeis hand-warm

    Push in cartridge Set threadedrod rotating/impacting

    Visual checkof mortar fillingquantity

    Observe thehardening time

    Mount component,apply torque

    EuropeanTechnical

    ApprovalOption 8

    for uncracked concrete

    FireResistance

    Drill hole cleaning

    Cleaning the drill hole: 1x blow-out, 1x brush-out,1x blow-out, 1x brush-out

    Installation instructions

    Set anchor bar rotating and + impacting with hammerdrill or percussion drill.

    21.2

    21.2

  • 7/27/2019 Chemical Anchors

    2/2F0072

    1) The part safety coefficients of the resistances and a part safety coefficient of the effects of F= 1.4 have been takeninto account. For the combination of tensile and transverse loads, for edge influence anddowel groups, pleaserefer to the Directive for European Technical Approval (ETAG) Appendix C.

    2) Maximum long-term temperature.3) Maximum short-term temperature.4) Cleaning brush without M6 connecting thread.

    Performance data

    Anchor diameter M8 M10 M12 M16 M20 M24

    Pressure zone(uncracked concrete C20/25 Nperm [kN] = C20/25 7.9 11.9 15.9 19.8 29.8 35.7

    M8: s

    3 hef, c

    1.5 hef 50C2)

    /80C3)

    M10-M24: s 2 hef, c 1hef)

    Pressure zone(uncracked concrete C20/25, Vperm [kN] = C20/25 5.1 8.0 12.0 22.3 34.9 50.3c 10 hef)

    Permissible bending torque Mperm [Nm] 10.9 21.1 37.1 94.9 185.7 320.6

    Fire resistance time F30 [kN] 2.3 3.64 5.26 9.79 15.28 22.01

    F60 [kN] 1.29 2.04 3.07 5.72 8.93 12.86

    F90 [kN] 0.79 1.3 2.0 3.68 5.75 8.28

    F120 [kN] 0.53 1.0 1.5 2.67 4.16 6.0

    Perm

    .centered

    ten

    sileload1)

    ofas

    ingleanc

    hor

    w/oedgeinfluence

    Perm.

    transv.

    load1)

    ofasingleanc

    hor

    w/oedgeinfluence

    MWF-04/08-04277-

    Characteristic values

    Minimum axial spacing smin [mm] 40 45 55 65 85 105

    Axial spacing scr,N [mm] 240 180 220 250 340 420Minimum edge spacing cmin [mm] 40 45 55 65 85 105

    Edge spacing ccr,N [mm] 120 90 110 125 170 210

    Minimum component thickness hmin [mm] 110 120 140 160 220 260

    Effective anchoring depth hef [mm] 80 90 110 125 170 210

    Nom. drill dia. d0 [mm] 10 12 14 18 25 28

    Drill cutting dia. dcut [mm] 10.5 12.5 14.5 18.5 25.5 28.5

    Drilled hole depth h0 [mm] 80 90 110 125 170 210

    Through-hole incomponent to be connected

    df [mm] 9 12 14 18 22 26

    Torque during anchoring Tinst = [Nm] 10 20 40 80 120 180

    Cleaning brush dia. D [mm] 10.8 13 15 19 27 29

    Drill hole cleaning M8 M 24: 1x blow-out, 1x brush-out, 1x blow-out, 1x brush-out

    Cleaning brush (steel) Art. No. P. Qty. =1 0905 499 001 0905 499 002 0905 499 003 0905 499 004 0905 499 006 0905 499 0084)

    Machine mounting Art. No. P. Qty. =1 Hexagon:Art. No. 0905 499 101 SDS plus:Art. No. 0905 499 102

    Extension Art. No. P. Qty. =1 0905 499 111

    Brush template Art. No. P. Qty. =1 0905 499 099

    Blow-out pump Art. No. P. Qty. =1 Blow-out pump:Art. No. 0903 990 001

    Anchor dimensionsAnchor diameter M8 M10 M12 M 16 M20 M24

    Total length l [mm]

    max. mounting height tfix[mm]

    DesignationAnchor bar

    W-VD-A/S Anchor Bar,galvanized steel

    Art. No.

    Packing unit P. Qty.

    DesignationShear-anchor mortar cartridge

    W-VD shear-anchor mortarcartridge

    Art. No.

    Packing unit P. Qty. [pieces]

    110

    150

    115

    130

    165

    190

    135

    160

    210

    250

    300

    165

    190

    230

    250

    300

    220

    260

    300

    260

    300

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10 5 5

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0

    1

    0 5 5

    59151

    081

    10

    59151

    081

    50

    59151

    101

    15

    59151

    101

    30

    59151

    101

    65

    59151

    101

    90

    59151

    121

    35

    59151

    121

    60

    59151

    122

    10

    59151

    122

    50

    59151

    123

    00

    59151

    161

    65

    59151

    161

    90

    59151

    162

    30

    59151

    162

    50

    59151

    163

    00

    59151

    202

    20

    59151

    202

    60

    59151

    203

    00

    59151

    242

    60

    59151

    243

    00

    59150

    080

    80

    59150

    080

    80

    59150

    100

    80

    59150

    100

    80

    59150

    100

    80

    59150

    100

    80

    59150

    120

    95

    59150

    120

    95

    59150

    120

    95

    59150

    120

    95

    59150

    120

    95

    59150

    160

    95

    59150

    160

    95

    59150

    160

    95

    59150

    160

    95

    59150

    160

    95

    59150

    201

    75

    59150

    201

    75

    59150

    201

    75

    59150

    242

    10

    59150

    242

    10

    W-VDM8

    W-VDM8

    W-VDM10

    W-VDM10

    W-VDM10

    W-VDM10

    W-VDM12

    W-VDM12

    W-VDM12

    W-VDM12

    W-VDM12

    W-VDM16

    W-VDM16

    W-VDM16

    W-VDM16

    W-VDM16

    W-VDM20

    W-VDM20

    W-VDM20

    W-VDM24

    W-VDM24

    Fire resistance duration

    20

    60

    15

    30

    65

    90

    10

    35

    85

    125

    175

    20

    45

    85

    105

    155

    20

    60

    100

    15

    55

    W-VD-A/SM8-20/110

    W-VD-A/SM8-60/150

    W-VD-A/SM10-15/115

    W-VD-A/SM10-30/130

    W-VD-A/SM10-65/165

    W-VD-A/SM10-90/190

    W-VD-A/SM12-10/135

    W-VD-A/SM12-35/160

    W-VD-A/SM12-85/210

    W-VD-A/SM12-125/250

    W-VD-A/SM12-175/300

    W-VD-A/SM16-20/165

    W-VD-A/SM16-45/190

    W-VD-A/SM16-85/230

    W-VD-A/SM16-105/250

    W-VD-A/SM16-155/300

    W-VD-A/SM20-20/220

    W-VD-A/SM20-60/260

    W-VD-A/SM20-100/300

    W-VD-A/SM24-15/260

    W-VD-A/SM24-55/300

    W-VD/SShear-Anchor Cartridge System 21.1