Chem Cad Features

download Chem Cad Features

of 13

Transcript of Chem Cad Features

  • 7/25/2019 Chem Cad Features

    1/13

    Chem Cad Features

  • 7/25/2019 Chem Cad Features

    2/13

  • 7/25/2019 Chem Cad Features

    3/13

  • 7/25/2019 Chem Cad Features

    4/13

    Inputs and OutputsText Reports

    CHEMCAD can produce a wide array of customizable text-based simulationreports, based on stream data, Unit Operation data, flow sheet data, or

    dynamics. If you prefer, you can produce one consolidated report incorporating

    all of the available text report data.

    Report Setup

    Before you run, view, or print reports, you should check the settings thatdetermine which programs CHEMCAD will use to display and print your reports.

    For individual text reports, you can choose to use either WordPad or Excel.

    By default, CHEMCAD uses WordPad. To switch to Excel, select Tools > Options >

    Report Viewer Settings and then check the box called Use Microsoft Excel instead

    of WordPad. Click OK to return to the main CHEMCAD workspace.

    For the consolidated report, you can use either Word or Excel. To choose a

    program to display and print this report, select Report > Consolidated Report,

    then click Report Format at the top of the Consolidated Report menu.

  • 7/25/2019 Chem Cad Features

    5/13

    Types of Report

    Stream-based Reports

    UnitOp-based Reports

    Flow sheet-based Reports

    Dynamics Reports

    Consolidated Report

    Graphical Reports

  • 7/25/2019 Chem Cad Features

    6/13

  • 7/25/2019 Chem Cad Features

    7/13

  • 7/25/2019 Chem Cad Features

    8/13

    Graphical ReportsThermo physical Data Graphs

    CHEMCAD offers a number of graphical reports that relate specifically to the selected

    components and thermodynamics options. To access any of these plots, select the

    appropriate item from the Plot menu.TPXY

    This selection generates vapor-liquid equilibrium curves between any two

    components, with an optional third component. You can include TPXY, TXY, activity

    coefficient, and fugacity coefficient curves.

    Binary LLE

    This selection generates liquid-liquid equilibrium curves between any two

    components.

    Binodal Plot

    This selection generates a ternary phase diagram showing the distribution of three

    selected components in two liquid phases.

    Residue CurvesThis selection generates and plots a graphical display of distillation zones, azeotropes,

    and residue curves associated with a user-specified tertiary mixture.

    Binodal/Residue Curves

    This selection creates a plot that combines the curves from a binodal plot and a

    residue curve plot. This is useful when working with heterogeneous azeotropic

    distillation.

  • 7/25/2019 Chem Cad Features

    9/13

    Flow sheet-based Graphs

    To view graphical reports that reflect your overall simulation, select one of the

    following from the Plot menu:

    Stream Properties: Plots one selected stream property for a selected stream in

    the flow sheet

    Phase Envelopes: Plots a phase envelope for a given stream, highlighting the

    critical point of the mixture; can include plots at vapor fractions

    Composite Curves: Plots composite heat curves for the entire flow sheet, as

    well as optional heat curves for individual UnitOps

    Pseudo component Curves: Displays a plot of one or more distillation curves

    for a stream.

  • 7/25/2019 Chem Cad Features

    10/13

    UnitOp-based Plots

    CHEMCAD offers several plots that display data for a single UnitOp. To access any of

    these plots, select Plot > UnitOp Plots and then select one of the following options.Tower Profiles

    This selection plots compositions, temperature, and flow profiles for distillation columns.

    Heat Curves

    This selection plots heating and cooling curves for a selected heat exchanger.

    Plug Flow Reactor Profile

    This selection plots the temperature or composition profiles along the axial length of a

    kinetic plug flow reactor.

    Pipe Profile

    This selection plots fluid properties for pipe UnitOps along the axial length of the pipe.

    This plot requires that the pipe contain multiple segments.

    Controller Convergence

    For controllers that have not converged, this plot enables you to diagnose the controller

    behavior that is preventing convergence. The plot shows how the controller error

    function changes with iteration.

  • 7/25/2019 Chem Cad Features

    11/13

  • 7/25/2019 Chem Cad Features

    12/13

    Process Flow DiagramsFlow sheet Databoxes

    CHEMCAD offers four types of databoxes:

    Stream Box: Lists the streams that you select in a single table, along with the

    stream properties that you choose to include

    UnitOp Box: Generates a separate databox for each selected UnitOp

    TP Box: Generates separate summary databoxes for selected streams

    Excel Range Box: References a range of cells from an Excel worksheet

    TP BoxesCHEMCAD can create databoxes, called TP boxes, which display any combination of

    temperature, pressure, and flow rate for all streams or selected streams on a flow sheet.

    Excel Range BoxesAn Excel range box displays dynamic data from a specified cell range in a specified

    Excel worksheet.

  • 7/25/2019 Chem Cad Features

    13/13

    TP boxes added to a simple flow sheet