Chapter 2 Incompressible Flow Through Pipes
Transcript of Chapter 2 Incompressible Flow Through Pipes
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 1/38
Chapter 2:
Analysis of Steady Flow in Pipelines
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 2/38
Learning outcomes
• To apply energy equation in pipes
• To analyze of flow and piping systems
including pipe in series and pipes in parallel by
applying energy equations
• To analyze pipe systems consist numerous
pipes connected in a complex manner with
general entry and withdrawal points by using
Quantity Balance Method
2UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 3/38
Content
• Introduction
• Incompressible flow through pipes
•
Flow through pipes in series• Flow through pipes in parallel
• Flow through branching pipes
• Pipe networks• Quantity Balance Method
3UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 4/38
Introduction
• This chapter concerned with the analysis of flow in
pipes and piping systems including pipe in series and
pipes in parallel.
• Dealing with flow in circular pipes flowing full understeady conditions and flowing under gravity.
• Analyses problems involving pipelines, e.g. flow
between reservoirs, water flow from a reservoir
discharging to atmosphere, from higher to lower
elevation reservoir or vice versa.
4UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 5/38
Introduction
• Normally uses energy and continuity equation
to solve problems.
• Method of solving:
– Number of equations needed is the same as the
number of unknowns to be solved
– Successive corrections until the continuity
equation is satisfied (trial & error)
5UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 6/38
Incompressible flow through pipes
• Incompressible : density is constant throughout
• For a circular cross-section conduit flowing
full:
– Head loss due to friction by Darcy Weisbach
– Pressure loss by Darcy Weisbach
gd
fLvh f
2
42
(2.1)
d
v fL p
2
4 2 (2.2)
6UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 7/38
Incompressible flow through pipes
• But
•
Therefore (2.1) & (2.2),
4
2d
Qv
5
2
03.3 d
flQh f
5
224.3
d
flQ p
(2.3)
(2.4)
7UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 8/38
Example 2.1(Douglas, 2006)
• Water discharges from reservoir A through a 100 mm
diameter pipe, 15 m long, which rises to the highest
point at B, 1.5 m above the free surface of the
reservoir and discharges direct to the atmosphere atC, 4 m below the free surface at A. The length of pipe
L1 from A to B is 5 m and the length of pipe L2 from
B to C is 10 m. Both the entrance and exit of the pipe
are sharp and the value of f is 0.08. Calculate, – The mean velocity of the water leaving the pipe at point C
– The pressure at point B
8UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 9/38
UiTMKS/ FCE/ BCBidaun/ ECW301 9
A
2 m
B
4 m
C
L1
L2
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 10/38
Flow through pipes in series
• Pipes in series are pipes of different diameters
are connected end-to-end to form pipeline to
form a pipeline.
• The total loss of energy, or pressure loss, over
the whole pipeline will be the sum of the
losses for each pipe together with any
separation losses that might occur at the junctions.
10UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 11/38
Example 2.2 (Douglas, 2006)
• Two reservoirs A and B have a difference level of 9 m
and are connected by a pipeline 200 mm in diameter
over the first part AC, which is 15 m long, and then
250 mm diameter for CB, the remaining 45 m length.The entrance to and exit from the pipes are sharp and
the change of section at C is sudden. The friction
coefficient f is 0.01 for both pipes. List the losses of
head that occur and calculate the system flow rate.
11UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 12/38
12UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 13/38
Apr 2010
• Two pipes are connected in series and is used to connecttwo reservoirs as shown in Figure Q2(b). Both pipes are 500m long and have diameters of 0.7 m and 0.5 m respectively.The discharge from reservoir A to reservoir B is 0.8 m3 /sand the elevation of water surface in reservoir A is 85 m.Using the appropriate equations and assuming sharp exitand entry as well as existence of sudden contraction at the junction, determine :
– velocity for each pipe
– head losses due to friction, separation and fittings
– elevation of water surface in reservoir B
(Cc = 0.674, μ = 1.14 x 10-3 Pa.s and k = 0.15 mm)
13UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 14/38
14UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 15/38
Incompressible flow through pipes in parallel
• When two reservoirs are connected by two ormore pipes in parallel, the fluid can flow from oneto the other by a number of alternative routes.
• Difference in head h available to produce flowwill be the same for each pipe.
• Thus pipe can be considered separately,independent of other parallel pipes.
• Steady flow energy equation can be applied forflow by each route.
• The total volume rate of flow will be the sum of volume rates of flow in each pipe.
15UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 16/38
Example 2.3 (Douglas, 2006)
• Two sharp-ended pipes of diameter d1 = 50 mm,and d2 = 100 mm, each of length L = 100 m, areconnected in parallel between two reservoirs
which have a difference of level h = 10 m, as infigure. If the Darcy coefficient f = 0.008 for eachpipe, calculate,
a. the rate of flow for each pipe,
b. diameter D of a single pipe 100 m long thatwould give the same flow if it was substituted forthe original two pipes.
16UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 17/38
Incompressible flow through branching pipes
• Branching pipes - consist of one or more pipesthat separate into two or more pipes
• The basic principles that must be satisfied are:
• Continuity - at any junction the total mass flowrate towards the junction must be equal the totalmass flow rate away from it
• There can be only one head value at any point
• The energy equation must be satisfied for eachpipe
17UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 18/38
•
Figure 2.4 shows a simple branching pipesystem where there are three tanks connected
by three pipes that join at D
•
Actual direction of flow depends on – Tank pressures and elevation
– Diameters, length and kinds of pipe
•
The system must satisfy two equation i.e.Darcy Weisbach and continuity equation
18UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 19/38
UiTMKS/ FCE/ BCBidaun/ ECW301 19
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 20/38
•
The inflow and outflow at the junction D mustbe equal (continuity equation)
• The flow must be from the highest tank to the
lowest tank.
• Therefore, continuity equation can be
321321 or QQQQQQ
20UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 21/38
• If the HGL at junction D is above the elevationof the intermediate tank B – the water is
flowing into tank B.
• If the HGL at junction D is below tank B – thewater is flowing out from tank B.
• General problem: to find the flow rate in each
pipe
21UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 22/38
Example 2.4 (Douglas, 2006)•
Water flows from reservoir A through a pipe of diameter d1 = 120 mm and length L1 = 120 m to
junction D, from which a pipe of diameter d2 = 75
mm and length L2 = 60 m leads to reservoir B in
which the water level is 16 m below that in reservoirA. A third pipe of diameter d3 = 60 mm and length L3
= 40 m, leads from D to reservoir C, in which the
water level is 24 m below that in reservoir A. Taking f
= 0.01 for all the pipes and neglecting all losses otherthan those due to friction, determine the discharge in
each pipe.
UiTMKS/ FCE/ BCBidaun/ ECW301 22
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 23/38
UiTMKS/ FCE/ BCBidaun/ ECW301 23
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 24/38
Pipe networks
• A pipe network is a set
of pipes which are
interconnected so that
the flow from a giveninput or to a given outlet
may come through
several different routes.
UiTMKS/ FCE/ BCBidaun/ ECW301 24
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 25/38
• An alternative approach is used to analyse the
systems by means of successive approximations,
assuming values for the flow in each pipe, or theheads at each junction, and checking whether the
values chosen satisfy the requirements:
–
The loss of head between any two junctions mustbe the same for all routes between these junctions
– The inflow to each junction must equal the outflow
from that junction
UiTMKS/ FCE/ BCBidaun/ ECW301 25
Loss of
head in
pipe bc
+ Loss of
head in
pipe de
= Loss of
head in
pipe bd
+ Loss of
head in
pipe ce
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 26/38
Quantity balance method
• Can be used when the heads at various points in a
pipe network are known.
• Estimate the head at each junction and Q is calculated
for each pipe from the difference of head h betweenthe junctions at each end of pipe and its resistance
coefficient K by,
• If the inflow does not equal to outflow for each
junction, the original estimated head must be
corrected.
2KQh
26UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 27/38
• If the head at b has been overestimated by δh
relative to the head at a, c, and d, the values of
Qab and Qcb will be too small and the value of
Qbd will be too great.
• Differentiating
UiTMKS/ FCE/ BCBidaun/ ECW301 27
2KQh
hnh
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 28/38
• Therefore, the estimated head at b is reduced
by δh, the flows in ab and cb will be increased
to Qab + δQab and Qcb + δQcb.
• If the flows are correct, inflow and outflow at
b will be balanced:
bd bd cbcbabab QQQQQQ
bdinFlowcbinFlowabinFlow
28UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 29/38
• If hAD, hBD and hDC , are
the assumed losses in
pipe ab, cb and bd, used
to calculate Qab, Qcb andQbd,
hnh
ab
abab
hnhQQ
cb
cbcb
h
nh
bd
bd bd
29UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 30/38
• Substituting,
• Sign convention: flow towards junction b both Q and
h are posititve
nh
Q
Qh
nh
Q
nh
Q
nh
Q
QQQ
h
hnh
QQh
nh
QQh
nh
bd
bd
cb
cb
ab
ab
bd cd ab
bd
bd bd
cb
cbcb
ab
abab
bdinFlowcbinFlowabinFlow
30UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 31/38
• The process is repeated until ΣQ has been
reduced to negligible quantity (approaching
zero)
junctionthetowards
flowstheof sumAlgebraic DC BD AD QQQQ
31UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 32/38
Example 2.5 (Douglas, 2006)
• A reservoir A with its surface 60 m above the
datum supplies water to a junction D through a
300 mm diameter pipe, 1500 m long. From the
junction, a 250 mm diameter pipe, 800 m long,feeds reservoir B, in which the surface level is
30 m above datum, while a 200 mm diameter
pipe, 400 m long, feeds reservoir C, in which
32UiTMKS/ FCE/ BCBidaun/ ECW301
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 33/38
UiTMKS/ FCE/ BCBidaun/ ECW301 33
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 34/38
Example 2.6 (Douglas, 2006)•
Water flows in the parallel pipe system as shown infigure for which the following data are available:
UiTMKS/ FCE/ BCBidaun/ ECW301 34
Pipe Diameter (m) Length (m) f
AaB 0.10 300 0.0060
AbB 0.15 250 0.0050
AcB 0.20 500 0.0050
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 35/38
• The supply pipe to point A is of 0.30 m
diameter and the mean velocity of water in it is
3 m/s. If the elevation of point A is 100 m and
the elevation of point B is 30 m above datum,calculate the pressure at point B if that at A is
200 kPa. What is the discharge in each pipe?
Neglect all minor losses.
UiTMKS/ FCE/ BCBidaun/ ECW301 35
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 36/38
Review of past semesters’
questions
UiTMKS/ FCE/ BCBidaun/ ECW301 36
7/29/2019 Chapter 2 Incompressible Flow Through Pipes
http://slidepdf.com/reader/full/chapter-2-incompressible-flow-through-pipes 37/38
Oct 2010
• Water flows from reservoir A through pipe 1 to
junction J which in turn flows to reservoir B
through pipe 2 and reservoir C through pipe 3
as shown in figure. Using analytical methodand neglecting all losses other than those due
to friction, determine the flow rate and velocity
for each pipe. Assume that the friction factor, f is 0.01 for all pipes.
37UiTMKS/ FCE/ BCBidaun/ ECW301