Page 2: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Earthquake Earthquake cause shaking of ground, so a building resting on

it will experience motion at its base. The roof has a tendency to stay in its original position and the

roof experiences a force, called inertia force. Inertia force is the multiplication of the weight and the

acceleration, so larger the weight of the building more the earthquake shaking.

Engineering representation of earthquake force

Page 3: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Masonry Structures

Masonry is brittle and tensile and shear strength is very low.

Due to Large mass of masonry structures, heavy weight attracts large amounts of seismic forces.

Wall to wall connection and roof connection is generally weak.

Stress concentration occurs at the corners of windows and doors.

Page 4: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Out of plane failure In plane failure Diaphragm failure Connection Failure Failure due to opening of wall Pounding Non-structural component failure

Failure Modes of a Masonry buildings

Page 5: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Out of Plane FailureThe Earthquake force is

perpendicular to the plane.The wall tends to overturn or bend.This causes the partial or full

collapse of the wall.This is due to Inadequate anchorage

of wall and roof , long and slender wall, etc.

Characterized by vertical cracks at corner, cracks at lintel, roof level and gable wall, etc.

Page 6: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

In Plane Failure

The Earthquake force is parallel to the planeThe wall is shear off or bendX- cracks occurs Characterized by vertical cracks at wall intersection,

separation of corners of two walls, spalling of materials, etc

Page 7: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Diaphragm Failure Lack of anchoring produce a push of diaphragm against the

wall. Absence of good shear transfer between diaphragms and

reaction wall accounts for damage at corner of wall Rare phenomenon in the event of seismic motion Separation of wall and diaphragm cause collapse of buildings

Page 8: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Connection failure For given direction of earthquake, wall A acts as a shear

wall and B acts as flexure wall. If the walls are not tied together wall B overturn (out of

olane) and wall A slides (in plane) and collapse occurs. Masonry units should tied properly

Page 9: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Failure due to opening in walls Opening will obstruct the flow of forces from one wall to

another. Large opening in shear wall reduces the strength of wall

against the inertia forces. Results diagonal cracks in the areas of masonry between

opening and cracks at the level of opening. Thus, openings should small and away from corners.

Page 10: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Pounding When the roofs of two adjacent buildings are at different

levels, during earthquake, two buildings strike against each other is called pounding.

Pounding results into cracking of the wall.

Page 11: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Non Structural components failure

Falling of plaster from walls and ceiling.Cracking and overturning of parapets,

chimneys, etc.Cracking and overturning of partition walls.Cracking of glasses.Falling of loosely placed objects.

Page 12: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Ductile behaviour of reinforced & unreinforced masonry

It is the capacity of an element or structure to undergo large deformation without failure.

Masonry is brittle in nature. Ductility of masonry structure is governed by the ductility

of masonry units & properties of mortar. Unreinforced masonry cannot withstand tension so cracks

develops. In-plane & out-of-plane failure is also due to ductility of

masonry. To improve ductility reinforcing bars are embedded in the

masonry, called reinforced masonry which can resist the seismic force more than unreinforced masonry.

Page 13: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Brittle and Ductile force-deformation behavior

Brittle

Ductile

Δy ΔuDeformation

Page 14: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

1. Walls tend to tear apart.

Page 15: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

2. Walls tend to shear off diagonally in direction.

Page 16: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

3. Failure at corners of walls

Page 17: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

4. Walls tend to collapse

Page 18: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

5. Failure at corners of openings

Page 19: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

6. Hammering/pounding between two adjacent buildings

Page 20: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.
Page 21: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

7. Separation of thick wall into two layers

Page 22: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

8.Separation on unconnected wall at junction

Page 23: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

9.Seperation of wall from roof

Page 24: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Non-integrity of wall floor and roof. Configuration – irregularity of building causes

torsional effect. Large opening of the building. Inappropriate position of opening. Lack of cross wall in large length of wall. Lack of reinforcement make the masonry building

brittle. Pounding effect. Lack of anchoring element between two walls.

Major causes of failure of masonry buildings

Page 25: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Elements of Lateral Load Resisting Masonry

System

Page 26: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Horizontal bands for integrity Connecting peripheral walls for

structural robustness and integrity Plinth band Lintel band Roof band Gable band

Page 27: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.
Page 28: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.
Page 29: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.
Page 30: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Roof structure

Light and strong roof is

desirable.

Secure tiles/slates or use GI

sheets.

Good jointing in trusses

Concrete floors in 1:2:4

concrete with reinforcement

in both directions and bend

up near supports.

Page 31: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.
Page 32: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Overall arrangement of masonry structure

Page 33: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Chapter-10Testing of masonry

elements

siddharth shankarPulchowk Campus

Department of Civil Engineering

Page 34: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Compressive Strength of Bricks and wall

Page 35: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Testing of Wall in compression

Page 36: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Diagonal Shear Test

Page 37: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.
Page 38: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.
Page 39: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.
Page 40: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Normally carried out:1. Periodically to evaluate the performance of building

2.To gather information on old building in order to ascertain the methods of repair or to demolish

3. To ascertain the strength of concrete if cube tests failed.

Page 41: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

NON DESTRUCTIVE TEST (NDT)

Elastic wave tomography Rebound Hammer / Schmidt Hammer Ultrasonic Pulse Velocity Impact Echo Test X-Rays Flat Jack Test

Page 42: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Elastic wave tomography Technique used for locating shallow delaminations,

cracks, and voids. Elastic wave tomography is based on two basic

principles from heat transfer: conduction and radiation. Sound materials with no voids, gaps, or cracks are more thermally conductive than materials that are delaminated or contain moisture.

This allows rapid areal mapping of internal conditions. It should be noted that the IT method is most useful for the detection of shallow defects and flaws.  

Tests For: Voids, Cracks, Moisture.

Page 43: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.
Page 44: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.
Page 45: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.
Page 46: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Rebound Method Can be used to determine the in-place compressive

strength of concrete within a range of 1500 – 8000 psi (10-55MPa)

A quick and simple mean of checking concrete uniformity.

Measure the distance of rebound of a spring-loaded plunger after it struck a smooth concrete surface.

Results of the test can be affected by factors such as smoothness of concrete surface, size, shape, rigidity of specimen, age & moisture condition.

Type of coarse aggregate & the carbonation of the surface.

Page 47: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Nondestructive Test Re-bound hammer Method

Page 48: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Nondestructive Test Methods Rebound Hammer Tests

Schmidt Hammer

Page 49: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Rebound Method Using Rebound Hammer

Page 50: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Ultrasonic Pulse Velocity It uses measurement of the speed of ultrasonic

pulses through the concrete to correlate concrete strength to standard strength.

Allows the determination of compressive concrete strength and location of cracks.

It will identify non homogenous condition in the structure such as honeycomb, voids and cracks.

Size of cracks can also be determined.

Page 51: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Ultrasonic Pulse Velocity

Page 52: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Flat Jack Test Flat jack testing is a nondestructive test of

evaluating existing masonry structure. It does not require removal of masonry units - only the removal of small portions of mortar is enough. The flat jack test uses small, thin, hydraulic jacks to apply a force to a section of an existing masonry wall, and the method uses measuring devices to determine the resulting displacement of the masonry.

Page 53: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Flat jack testing has many useful applications:

It can be used to determine masonry compressive modulus, which is the stress/strain relationship of the masonry, or axial stress by applying axial load and measuring resulting axial deformation.

It can be used to estimate compressive strength and measure the shear strength.

If the destruction of the masonry units is acceptable, it can be used to directly measure the compressive strength by testing the masonry to failure.

Page 54: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Flat-Jack Test

Page 55: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Push Shear Test

Page 56: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

Prepare the test location by removing the brick, including the mortar, on one side of the brick to be tested. The head joint on the opposite side of the brick to be tested is also removed. Care must be exercised so that the mortar joint above or below the brick to be tested is not damaged.

The hydraulic ram is inserted in the space where the brick was removed. A steel loading block is placed between the ram and the brick to be tested so that the ram will distribute its load over the end face of the brick. The dial gauge can also be inserted in the space.

Push Shear Test

Page 57: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.

The brick is then loaded with the ram until the first indication of cracking or movement of the brick.

The ram force and associated deflection on the dial gauge are recorded to develop a force-deflection plot on which the first cracking or movement should be indicated. A dial gauge can be used to calculate a rough estimate of shear stiffness

Push Shear Test

Page 58: Chapter-09 Masonry Structures under later loads Siddharth shankar Department of Civil(structure) Engineering Pulchowk Campus.